Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹16.0 Cr
Closing Date
26 Apr 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
NBCC Bhawan
NBCC Bhawan
Development of New Circuit House at Rourkela in Sundargarh District of Odisha
NBCC/SBG/O/DMF/CircuitHouse/Rourkela/2021/006~EWa8ba176c1967f471e53cbbf7
NBCC/SBG/O/DMF/CircuitHouse/Rourkela/2021/006
Open Tender-Domestic
Civil Works General
NBCC Bhawan
₹11,800
Exempted
26 Apr 2021
13 Apr 2021
26 Apr 2021
13 Apr 2021
26 Apr 2021
Earth Work in exavation of foundation in oridinary
soil within initial leads of 50m & lifts of 1.5m including
1 dressing and levelling of bed etc. and adding 4838.85 Cum 130.82 632999.00
contractor's profit and over head charges, etc.
complete in all respect
Extra lift of 1.5m or part there of over the initial lift of
1.5m in all kinds of embankments and road works and
ordinary earth work in general including labour, T&P &
material etc. complete in all respect.
Filling in F & P with excavated materials including
3 watering and ramming as directed by the Engineer-n- 4331.75 Cum 86.02 372599.81
charge.
Supplying & filling foundation and plinth with course
4 sand well watered and rammed including cost, cost of 294.69 Cum 347.76 102481.39
all labour, carriage, royalty, etc complete.
Cement Concrete (1:4:8) using 4cm size hard granite
C.B. metal approved quality from approved quarry
including cost, carriage, royalty, cost of all labour. etc
complete.
Cement Concrete (1:3:6) using 4cm size hard granite
C.B. metal approved quality from approved quarry
including cost, carriage, royalty, cost of all labour. etc
complete.
ANTI-TERMITE TREATMENT :
Supplying , diluting and and preparing chemical
emulsion like CHLORPYRIPHOS or other chemicals
approved by central Insecticides Board or as directed
by the manufacturer and spraying the mixture uniformly
by sprayer as pre-constructional anti termite treatment
and creating a chemical barrier under and around wall
trenches, basement excavation, top surface of plinth
filling, junction of walls and floors along with external
7 perimeter of the building, surrounding the pipes and 2991.64 Sqm 91.84 274752.22
conduits etc. complete at the rate of 7.5 litres ( or as
directed by the manufacturer) per sqm on vertical and
5.0 liters per sqm on horizontal surfaces, 50% of the
emulsion to be filled in the holes made in trenches at
150mm center to center etc. complete.as per
IS:6313/1981 (PART-II) and as per the direction of
engineer-in-charge including all cost of materials
labour, taxes etc. all complete.
Treatment at points of contact of wood work by
chemical emulsion Chlorpyriphos emulsifiable
concentrate of 20% / Lindane (in oil or kerosene based
soulution) @ 0.5 litres per hole by drilling 6 mm dia
holes at downward angle of 45 degree at 150 mm
centre to centre and sealing the same.
Making plinth protection 50 mm thick of cement
concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded
stone aggregate 20 mm nominal size) over 75 mm bed
of dry brick ballast 40 mm nominal size well rammed
and consolidated and grouted with fine sand including
finishing the top smooth.
R.C.C. work of M-25 grade with 20mm and down
10 grade black hard granite (crusherbroken) stone chips
including hoisting and laying.
10.1 Foundation 443.62 Cum 5074.61 2251197.60
Grade Slab 254.15 Cum 5074.61 1289711.62
Plinth Beam 212.95 Cum 5074.61 1080637.77
10.2 R.C.C. Column
Ground Floor 207.24 Cum 5074.61 1051661.76
1st Floor 97.42 Cum 5165.44 503217.16
2nd Floor 9.89 Cum 5269.94 52119.67
10.3 R.C.C. Beam & Lintel
Ground Floor Roof 262.92 Cum 5074.61 1334215.94
1st Floor Roof 212.50 Cum 5165.44 1097656.00
2nd Floor Roof 7.85 Cum 5269.94 41369.00
10.4 R.C.C Roof Slab
Ground Floor 371.83 Cum 5074.61 1886891.49
1st Floor 349.94 Cum 5165.44 1807594.07
10.5 R.C.C. Staircase
Ground Floor 13.72 Cum 5074.61 69623.62
1st Floor 13.72 Cum 5165.44 70869.84
10.6 R.C.C Chajja
Ground Floor 0.60 Cum 5074.61 3044.76
1st Floor 0.48 Cum 5165.44 2479.41
10.7 R.C.C Walls
Ground Floor 21.10 Cum 5074.61 107074.23
1st Floor 63.18 Cum 5165.44 326352.50
2nd Floor 53.87 Cum 5269.94 283891.45
Rigid & smooth centering and shuttering for R.C.C.
foundation, plinth band and footing base of column,
11 mass concrete, precast slabs etc. including false works
and dismantling them after casting inclduing cost of
material & labour etc. all complete.
Foundation 481.43 Sqm 111.76 53806.93
Rigid & smooth centering and shuttering for R.C.C.
beams, column, grider and bressmer, etc. including
false works and dismantling them after casting
inclduing cost of material & labour etc. all complete.
Plinth Beam 1999.37 Sqm 804.27 1608037.31
Ground Floor Roof 3608.64 Sqm 804.27 2902328.11
1st Floor Roof 2291.91 Sqm 965.10 2211931.51
2nd Floor Roof 127.29 Sqm 1158.19 147426.26
Rigid & smooth centering and shuttering for R.C.C.
floor and roof slabs, landings, balconies, projecting,
13 sun shades and chhajjas including false works and
dismantling them after casting inclduing cost of
material & labour etc. all complete.
Upto 4.3 Meter Height
Ground Floor Roof 2513.95 Sqm 469.50 1180309.58
1st Floor Roof 2183.50 Sqm 563.36 1230096.56
2nd Floor Roof 74.73 Sqm 676.03 50522.85
Rigid & smooth centering and shuttering for R.C.C.
walls and fins inclding attached pillasters etc. including
false works and dismantling them after casting
inclduing cost of material & labour etc. all complete.
Ground Floor 179.71 Sqm 690.37 124066.03
1st Floor 742.23 Sqm 828.35 614827.70
2nd Floor 737.40 Sqm 994.11 733058.19
Rigid & smooth centering and shuttering for R.C.C.
stairs exluding landing but including railing including
false works and dismantling them after casting
inclduing cost of material & labour etc. all complete.
Ground Floor 69.84 Sqm 657.33 45907.79
1st Floor 69.84 Sqm 788.93 55098.73
Rigid & smooth centering and shuttering for R.C.C.
lintels including false works and dismantling them after
casting inclduing cost of material & labour etc. all
complete.
Ground Floor 246.01 Sqm 289.41 71197.26
1st Floor 208.07 Sqm 347.20 72241.90
For each additional height of 0.3m over initial height of
4.3m in ground floor and upto height of 5.5m.
For each additional height of 0.3m and extra over
Supplying, fitting and placing uncoated HYSD(Fe 500)
bar reinforcement including cutting, bending and
19 binding with binding wire complete as per drawing and
technical specification including T&P,material, labour
and lead & royalty.
Ground Floor 1464.93 Qtl. 8991.02 13171220.79
1st Floor 873.37 Qtl. 9017.01 7875184.28
2nd Floor 343.48 Qtl. 9044.34 3106548.53
2.5 cm. Damp proof course with C.C. (1:2:4) using
12mm. Size hard broken granite Chips including cost
of carriage and royalty of all materials, labour etc. all
complete under instruction of EIC.
Brick work with Fly ash Bricks 23cm x 11cm x 8cm size
having crushing strength not less than 75Kg/cm2 with
dimensional tolerance ±2 percent in cement mortar
(1:6) in superstructure including watering curing, cost
of carriage and royalty of all materials, cost of all
labour, etc complete.
Ground Floor 723.88 Cum 4191.49 3034134.33
1st Floor 549.87 Cum 4482.24 2464649.31
2nd Floor 14.11 Cum 4816.56 67961.66
Brick work with Fly ash Bricks 23cm x 11cm x 8cm size
having crushing strength not less than 75Kg/cm2 with
dimensional tolerance ±2 percent in cement mortar
(1:4) in superstructure including watering curing, cost
of carriage and royalty of all materials, cost of all
labour, etc complete.
Ground Floor Qty. 11.87 Cum 4400.93 52239.02
1st Floor 5.04 Cum 4691.68 23646.07
12mm thick C.P.(1:6) on brick masonary to the smooth
surface including watering, curing, cost, carriage,
royalty of all materials, cost of all labour, etc complete
as per the direction of E.I.C.
Ground Floor Qty. 5309.15 Sqm 148.18 786688.61
1st Floor 3504.75 Sqm 151.76 531880.86
2nd Floor 102.24 Sqm 157.92 16145.74
16mm thick C.P. (1:6) over brick masonary to the
smooth surface including watering, curing cost,
carriage, royalty, and taxes of all materials, cost of all
labour, etc complete as per the direction of E.I.C.
Ground Floor Qty. 1763.25 Sqm 228.82 403459.81
1st Floor 1649.31 Sqm 238.34 393089.95
2nd Floor 829.42 Sqm 254.13 210778.85
6 mm thick C.P. (1:4) to RCC surfaces / ceiling
finished smooth including closed deep chiping and
25 slury treatment , watering, curing cost, carriage &
royalty of all materials, cost of all labour, etc complete
as per the direction of E.I.C.
Ground Floor Qty. 2515.60 Sqm 166.77 419521.58
1st Floor 1676.05 Sqm 170.91 286457.06
2nd Floor 620.11 Sqm 175.28 108692.88
Supplying 300 mm wide Chicken wire mesh of
standard quantity as availbale in local market & fixing
with U nails 150 mm center to center before plastering
the junction of walls and beam/column in one vertical
plane to prevent surface cracks appearing between
junctions of column / beam and walls before plastering.
Payment shall be made by measuring the chicken wire
Providing plaster drip course/ groove in plastered
surface or moulding to R.C.C.projections. of size 40
mm x 12 mm deep in cement mortar proportion 1 : 3.
etc. all complete
12mm thick cement plaster (1 : 4) over brick work with
28 cement punning including material, T&P, lead & royality
and labour etc all complete
Ground Floor 100.49 Sqm 167.55 16837.30
1st Floor 274.65 Sqm 171.25 47033.26
Supplying, fitting and fixing tile in floors of approved
make conformaing to IS:13755 laid on 20 mm thick
cement mortar (1:4) and filling joints with white cement
of approved quality including cost of all materials, etc.
required for the work all complete as per direction of
29.1 Vitrified Tiles (600x600) mm
Ground Floor Qty. 1204.08 Sqm 1391.15 1675058.30
1st Floor 803.64 Sqm 1414.34 1136616.98
2nd Floor 10.63 Sqm 1460.82 15528.47
29.2 Granite tiles (20mm thk.)
Ground Floor Qty. 880.28 Sqm 2784.39 2451043.31
1st Floor 494.12 Sqm 2807.57 1387276.25
29.3 Anti-Skid / Matte Finish Vitrified Tile (300x300) mm
Ground Floor Qty. 318.87 Sqm 1174.22 374421.94
1st Floor 246.76 Sqm 1197.40 295470.11
Fixing tiles in skirting and risers of steps on 12mm thick
CP (1:3) jointed with neat cement slurry mixed with
pigments to match the shade of the tiles including cost,
carriage, cost of all labour etc. complete.
30.1 Vitrified Tiles
Ground Floor Qty. 81.40 Sqm 1508.53 122794.18
1st Floor 48.79 Sqm 1541.90 75229.50
2nd Floor 1.41 Sqm 1575.28 2221.14
30.2 Italian Grainite
Ground Floor Qty. 56.98 cum 7777.50 443162.18
1st Floor 89.94 cum 7810.77 702500.47
2nd Floor 78.78 Sqm 7844.14 617961.66
30.3 Anti-Skid / Matte Finish Tile (600x600) mm
Ground Floor Qty. 12.57 Sqm 1508.53 18962.20
1st Floor 9.98 Sqm 1541.90 15388.20
30.4 Granite tiles
Ground Floor Qty. 117.11 Sqm 1967.39 230401.28
1st Floor 68.66 Sqm 2000.77 137372.73
2nd Floor 0.60 Sqm 2034.14 1220.49
Fixing tiles in dados / wall tile on 12mm thick CP (1:3)
jointed with neat cement slurry mixed with pigments to
match the shade of the tiles including cost, carriage,
cost of all labour etc. complete.
31.1 Anti-Skid / Matte Finish Vitrified Tile (300x600) mm
Ground Floor Qty. 483.00 Sqm 1449.62 700164.53
1st Floor 356.38 Sqm 1482.99 528508.69
31.2 Granite Cladding
Ground Floor Qty. 13.04 Sqm 2131.25 27791.47
1st Floor 13.04 Sqm 2164.62 28226.70
31.3 Granite cladding around gate
Ground Floor Qty. 17.71 Sqm 2131.25 37744.40
1st Floor 4.43 Sqm 2164.62 9589.28
Providing and making of V groove at joints in lift wall
32 cladding as shown in architecture drawing including 97.52 RM 90.38 8814.25
grinding & polishing etc. all complete.
Providing and fixing approved shade and make
laminated wooden flooring 8mm thick with 4mm thk
33 foam including skirting profile of 10cm height with all 360.90 Sqm 1932.34 697380.06
material, T& P and labour etc. all complete as per
specification under instruction of EIC.
Priming one coat with any approved primmer including
34 cost of primmer & labour to give an even shade
excluding cost of primer.
Ground Floor Qty. 258.39 Sqm 59.54 15384.33
1st Floor 159.39 Sqm 60.38 9623.44
Painting two coats with approved enamel paints of
approved colour, shade over a coat of primer including
sand papering, polishing the surface, cost,
conveyances of all materials and cost of all labour etc,
complete as per specification & direction of Engineer-in-
charge.
Ground Floor Qty. 258.39 Sqm 148.96 38489.77
1st Floor 34.65 Sqm 158.82 5502.97
Finishing wall surface with two coat of Cement based
wall putty (water based) of approved make and finished
36 smooth & even surface to receive painting including
cost of scaffolding etc. with cost of all materials, labour
etc. complete.
Ground Floor Qty. 7832.12 Sqm 86.46 677196.42
1st Floor 5180.80 Sqm 101.02 523385.14
2nd Floor 722.35 Sqm 115.64 83532.55
Priming 1 coat with wall primer water bond cement
primer including all labour, materials etc. complete.
Ground Floor Qty. 7824.75 Sqm 60.48 473240.88
1st Floor 5180.80 Sqm 62.05 321458.28
2nd Floor 722.35 Sqm 63.73 46033.92
Wall painting 2 coats with plastic emulsion paint of
38 approved shade on new work to give an even shade
exculding cost of paint
Ground Floor Qty. 7824.75 Sqm 113.23 886012.09
1st Floor 5180.80 Sqm 115.02 595916.34
2nd Floor 722.35 Sqm 116.14 83896.62
Wall painting two coat with any approved weather coat
paint including cost of all materials, labour and T&P
require for the work etc. complete as directed by the
Ground Floor Qty. 1763.25 Sqm 82.43 145348.22
1st Floor 1649.31 Sqm 84.45 139280.93
2nd Floor 829.42 Sqm 86.58 71807.87
Providing and fixing fabric backing commercial grade
wall paper of approved shade by architect with
40 recommended adhesive of approved make. Cost to 60.16 Sqm 2380.45 143207.75
include preparation , T&P, Material and labour etc. all
complete under instruction of EIC .
Wall painting with texture paint any approved shade by
41 architect including material, labour and T&P etc. all 678.24 Sqm 616.00 417797.81
complete
Providing and laying water proofing treatment in
sunken portion of WCs, bathroom etc., by applying
cement slurry mixed with water proofing cement
compound consisting of applying : (a) First layer of
slurry of cement @ 0.488 kg/sqm mixed with water
proofing cement compound @ 0.253 kg/ sqm. This
layer will be allowed to air cure for 4 hours. (b) Second
42 layer of slurry of cement @ 0.242 kg/sqm mixed with 404.91 Sqm 296.80 120177.29
water proofing cement compound @ 0.126 kg/sqm.
This layer will be allowed to air cure for 4 hours
followed with water curing for 48 hours. The rate
includes preparation of surface, treatment and sealing
of all joints, corners, junctions of pipes and masonry
with polymer mixed slurry.
Providing gola 75 mm x 75 mm in cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate
43 10 mm and down gauge) including finishing with 617.35 RM 142.24 87811.86
cement mortar 1:3 (1 cement : 3 fine sand) all
complete as per direction of Engineer-in-charge.
Making khurras 45x45 cm with average minimum
thickness of 5 cm cement concrete 1:2:4 (1 cement: 2
coarse sand : 4 graded stone aggregate of 20 mm
44 nominal size) over P.V.C. sheet 1 mx1 mx400 micron, 16.00 Each 198.24 3171.84
finished with 12 mm cement plaster 1:3 (1 cement : 3
coarse sand) and a coat of neat cement,rounding the
edges, making and finishing the outlet complete.
Providing and laying integral cement based water
proofing treatment including preparation of surface as
required for treatment of roofs, balconies, terraces etc
consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75
kg/sqm of cement admixed with water proofing
compound conforming to IS. 2645 and approved by
Engineer-in-charge over the RCC slab including
adjoining walls upto 300 mm height including cleaning
the surface before treatment. (b) Laying brick bats with
mortar using broken bricks/brick bats 25 mm to 115
mm size with 50% of cement mortar 1:5 (1 cement : 5
coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-
charge over 20 mm thick layer of cement mortar of mix
1:5 (1 cement :5 coarse sand ) admixed with water
proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge to required slope and
treating similarly the adjoining walls upto 300 mm
height including rounding of junctions of walls and
slabs.
(c) After two days of proper curing applying a second
coat of cement slurry using 2.75 kg/ sqm of cement
admixed with water proofing compound conforming to
IS : 2645 and approved by Engineer-in-charge. (d)
Finishing the surface with 20 mm thick jointless cement
mortar of mix 1:4 (1 cement :4 coarse sand) admixed
with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge including laying
glass fibre cloth of approved quality in top layer of
plaster and finally finishing the surface with trowel with
neat cement slurry and making pattern of 300x300 mm
square 3 mm deep.
(e) The whole terrace so finished shall be flooded with
water for a minimum period of two weeks for curing
and for final test.“All above operations to be done in
order and as directed and specified by the Engineer-in-
Charge :
With average thickness of 120 mm and minimum
thickness at khurra as 65mm.
Providing and fixing M.S. grills / MS fabrication work of
required pattern in frames of windows etc. with M.S.
46 flats, square or round bars etc. including priming coat 40472.94 Kg 127.68 5167584.98
with approved steel primer all complete. Fixed to
openings /wooden frames with rawl plugs screws etc.
Providing, Supplying, fitting and fixing of stainless steel
of 304 grade in hand railling using 50mm dia of 32mm
x 32mm x 2mm @ 0.90mtr C/C and stainless square
pipe bracing of size 32mm x 32mm x 2mm 3 rows in
staircase as per approved design and specification,
buffing, polishing etc with cost, conveyance, taxes of
all materials, labour, T & P etc required for the work
complete in all respect.
Extra for pre finished nosing in Kota stone / granite /
marble slab.
Providing and fixing false ceiling at all height including
providing and fixing of frame work made of special
sections, power pressed from M.S. sheets and
galvanized with zinc coating of 120 gms/sqm (both side
inclusive) as per IS : 277 and consisting of angle cleats
of size 25 mm wide x 1.6 mm thick with flanges of 27
mm and 37mm, at 1200 mm centre to centre, one
flange fixed to the ceiling with dash fastener 12.5 mm
dia x 50mm long with 6mm dia bolts, other flange of
cleat fixed to the angle hangers of 25x10x0.50 mm of
required length with nuts & bolts of required size and
other end of angle hanger fixed with intermediate G.I.
channels 45x15x0.9 mm running at the spacing of
1200 mm centre to centre, to which the ceiling section
49 0.5 mm thick bottom wedge of 80 mm with tapered
flanges of 26 mm each having lips of 10.5 mm, at 450
mm centre to centre, shall be fixed in a direction
perpendicular to G.I. intermediate channel with
connecting clips made out of 2.64 mm dia x 230 mm
long G.I. wire at every junction, including fixing
perimeter channels 0.5 mm thick 27 mm high having
flanges of 20 mm and 30 mm long, the perimeter of
ceiling fixed to wall/partition with the help of rawl plugs
at 450 mm centre, with 25mm long dry wall screws @
230 mm interval, including fixing of gypsum board to
ceiling section and perimeter channel with the help of
dry wall screws of size 3.5 x 25 mm at 230 mm c/c,
including jointingand finishing to a flush finish of
tapered and square edges of the board with
recommended jointing compound , jointing tapes ,
finishing with jointing compound in 3 layers covering
upto 150 mm on both sides of joint and two coats of
primer suitable for board, all as per manufacturer's
specification and also including the cost of making
openings for light fittings, grills, diffusers, cutouts made
with frame of perimeter channels suitably fixed, all
12.5 mm thick tapered edge gypsum plain board
49.1 conforming to IS: 2095- (Part I) : 2011 (Board with BIS 549.89 Sqm 819.84 450821.82
Certification marks)
Providing and fixing of ACP false ceiling 0.5mm thick in
coloured coated with concealed grid system
600x600mm fixed in ceiling as per archetect including
material, labour T&P etc. all complete.
Providing and fixing dressed seasoned sal wood work
framed and fixed (wrought and put up) in trusses,
purlines, frames of doors, windows, ventilabours and
beams including all complete material, labour and lead
& royalty etc. all complete under instruction of Engineer-
in-charge.
Providing and fixing ISI marked flush door shutters
conforming to IS : 2202 (Part I) non-decorative type,
core of block board construction with frame of 1st class
hard wood and well matched commercial 3 ply
veneering with vertical grains or cross bands and face
veneers on both faces of shutters: 35 mm thick
including ISI marked Stainless Steel butt hinges with
necessary screws
Providing and fixing chromium plated brass 100 mm
mortice latch and lock with 6 levers and a pair of lever
handles of approved quality with necessary screws etc.
complete.
Providing and fixing chromium plated brass handles
with necessary screws etc. complete: 125 mm
Providing and fixing brass tower bolts, ISI marked,
required colour or shade, with necessary screws etc.
complete : 250x10 mm each
Providing and fixing bright finished brass hanging type
56 floor door stopper with necessary screws, etc. 75.00 each 101.92 7644.00
complete.
Providing and fixing aluminium die cast body tubular
type universal hydraulic door closer (having brand logo
57 with ISI, IS : 3564, embossed on the body, door weight 75.00 each 2047.36 153552.00
upto 35 kg and door width upto 700 mm), with
necessary accessories and screws etc. complete. each
Providing and fixing fire resistant door frame of section
143 x 57 mm having built in rebate made out of 16
SWG G.I. sheet (zinc coating not less than 120
gm/sqm) duly filled with vermuculite based concrete
mix, suitable for mounting 60 minutes fire rated door
shutters. The frame is fitted with intumuscent fire seal
58 22.40 metre 1660.96 37205.50
strip of size 10x4 mm (minimum) alround the frame and
fixing with dash fastener of approved size and make,
including applying a coat of approved brand fire
resistant primer etc. complete as per direction of
Engineer-in-charge (Dash fastener to be paid for
separately). .
Providing and fixing 50 mm thick glazed fire resistant
door shutters of 60 minutes fire rating conforming to
IS:3614 (Part-II), tested and certified as per laboratory
approved by Engineer-in-charge, with suitable
mounting on door frame, consisting of vertical styles,
lock rail, top rail 100 mm wide, bottom rail 200 mm
59 wide, made out of 16 SWG G.I.sheet (zinc coating not 10.56 sqm 7095.20 74925.31
less than 120 gm/m2) duly filled FR insulation material
and fixing with necessary stainless steel ball bearing
hinges of approved make, including applying a coat of
approved fire resistant primer etc. all complete as per
direction of Engineer-in-charge (panneling to be paid
for separately).
Providing and fixing factory made uPVC white colour
sliding glazed window upto 1.50 m in height dimension
comprising of uPVC multi-chambered frame with in-
built roller track and sash extruded profiles duly
reinforced with 1.60 ± 0.2 mm thick galvanized mild
60 steel section made from roll forming process of
required length (shape & size according to uPVC
profile), appropriate dimension of uPVC extruded
glazing beads and uPVC extruded interlocks, EPDM
gasket, wool pile, zinc alloy (white powder coated)
touch locks with hook, zinc alloy body with single nylon
Three track three panels sliding window with fly proof
S.S wire mesh (Two nos. glazed & one no. wire mesh
panels) made of (big series) frame 116 x 45 mm &
sash 46 x 62 mm both having wall thickness of 2.3 ±
0.2 mm and single glazing bead / double glazing bead
of appropriate dimension
Providing and fixing 12 mm thick frameless toughened
glass door shutter of approved brand and manufacture,
including providing and fixing top & bottom pivot &
double acting hydraulic floor spring type fixing
arrangement, 600mm long handle, patch lock and
making necessary holes, door handle, lock and stopper
etc. etc. for fixing required door fittings, all complete as
per direction of Engineer-in-charge.
Providing and applying crystel frostel film of 3M make
or equivalent on toughened doors & glass partition as
per Architect including material, labour and T&P etc.
complete in all respect.
5 cm thick grading concrete (1:2:4) on roof slab with
63 12mm & down grade size black hard granite chips for 338.82 Sqm 1733.32 587284.22
old & New work.
Providing and fixing of terracotta jali in façade work as
64 approved design by architect complete in all respect as 624.50 Sqm 3740.02 2335646.72
per specification and Engineer-in-charge.
Supplying & Installing of “T-Line” Toilet Cubicle Classic
Nylon module Series Size 1000(W) x 1500(D) x
1980(H): “T Line" Toilet cubical system Made out of
12mm thick solid Compact Laminate panels should be
resistant to heat, bacteria, water, chemical, scratch and
impact. Finished product should be as per approved
texture, shade & drawing detailing and developed
according to IS-2046 and BS-476/97 standards.
panel, door & divider panel to be fix vertically by using
aluminum black anodized profiles. The intermediate
panel is one continuous panel without any joints fix to
the wall & front panel by using "U" profile, as per the
required size Max depth -1500 mm, door width -600
mm )and front panel should be cut & fixed as per the
require measurement. Maximum width of the front
panel including door will be 1500mm.Center to center
for each cubical. All pilasters are to be supported by
adjustable foot of 150mmheight. Top rail & wall side
fixing with aluminium black anodized profile. Each
cubical should be equipped with Nylon. Hardware
Providing and fixing of stainless steel curtain rod 25mm
thick of grade SS 304 design as per architect including
66 both side bracket & curtain rod holder with fastner etc. 249.75 Rmt. 275.52 68811.12
complete in all respect under instruction of Engineer-in-
charge.
Providing and fixing of curtain in windows of linen
67 fabrics design as approved by Architect etc. all 315.00 Sqm 700.00 220500.00
complete as per EIC.
TOTAL AMOUNT 101755517
TOTAL AMOUNT 101755517
SCHEDULE OF QUANTITIES / BUDGETARY COST ESTIMATE
Rourkela Circuit House, ODISHA
S.No. DESCRIPTION UNIT QTY.
RATE AMOUNT
Design, supply, installation, testing & commissioning of Electrical installation:
1.0 SUB HEAD- I :- CIRCUIT CUM POINT WIRING WITH PVC/MS CONDUITING
Item Description for point wiring
1 All wiring shall be of 1100 volts grade.
All wiring shall be HR FRLS PVC insulated unsheathed, flexible, copper conductor, single or multi core as called for.
3 Earth wiring shall also be HR FRLS PVC insulated unsheathed, flexible, copper conductor, single core as called for.
4 Size of earth wire shall be the same as of the phase conductor or as specified otherwise.
All Switches & Sockets shall be of modular design complete with modular plate and suitable sized GI/ moulded boxes as
5 called for and shall be suitable upto 250V, AC supply.
The recessed Switches and Socket outlet boxes shall be of 16G GI and of the same make / manufacturer as of the
6 switches and sockets. Local make boxes are not to be used.
The surface mounted Switches & Sockets outlet boxes shall be moulded and of the same make / manufacturer as of the
Switches & Sockets.
8 Flexible conduits, where ever required, shall be of heavy duty and complete with couplers.
10 Conduiting may be concealed or surface mounted (Exposed) as the case may be.
11 Wiring terminations shall be made using proper sized thimbles/ lugs.
12 All circuit & point wiring shall be colour coded & shall have ferruling on either end for circuit identification.
The rates shall include material & labour for necessary length of circuit and point wiring, earth wiring, rigid and flexible
conduiting, bends, junction boxes, pull boxes, screws, washers, check nuts, couplers, saddles, hangers supports, GI pull
wire, civil work comprising chipping, cutting chases, fixing conduits & making good or surface clamping of conduit work
as the case may be, modular switches, socket outlets, Electronic fan regulators surface or recessed outlet boxes as the
13 case may be, ceiling rose, rigid and flexible conduit (GI/ MS) as may be required, connectors and terminal blocks of
proper rating etc. & sleeves etc. including lugs/ thimbles for terminations. Fan points wiring shall include switch as
well as electronic speed regulator, and fan hook box with fan hook.Wiring shall include conduiting and wiring (Phase,
Neutral, Earth) of light points/ fan points/ UPS and raw sockets outlets of required length from the distribution board via
switch to the point
Cost of circuit cum point wiring shall include everything and all items and accesOSRies to make the job complete in all
respects.
15 For Light Points, Ceiling Fan Points, Exhaust Fan Points, chandelier point & 6A Socket Outlet Points:
i) For switch Controlled light points.
ii) For switch Controlled Exhaust Fan points.
iii) For 6A switched socket outlets.
iv) For MCB Controlled Light points.
v) Wiring with 2x1.5 sqmm + 1x1.5 sqmm (earth wire).
vi) Wiring of required length from DB to point via switch for switch controlled points.
vii) Modular switch & plate for light points
viii) Modular switch and plate for Exhaust Fan point and modular switched socket near Exhaust Fan
ix) Modular 6A, 5 pin switched socket outlets
x) Suitable sizes of GI outlet boxes.
xi) MS/PVC conduiting of required length complete with bends, junction boxes and pull boxes.
xii) Surface or recessed conduiting including civil work like chase cutting and making good as required .
Item Described as above
Recessed wiring to Light Point / Fan Point / Exhaust Fan Point / Call
Bell Point with 1.50 sq. mm FR PVC insulated Single Core Multi
standard Copper Conductor of ISI marked with 20 mm dia non-
metallic PVC flexible conduit with 5 Amp, 250 Volt piano type swich
1.1 ISI marked and ceiling rose ISI marked mounted on MS box having
front bakelite cover of suitable size, MS box with 1.0 sq. mm FR
PVC insulated Single Core Multi standard Copper Conductor of ISI
marked as earth wire including all acceOSRies and connection as
per direction of engineer in charge.
a)Light Point
Midium Point 681 679.95 463044.19
b) Celling fan point
Midium(1200MM) Point 132 923.04 121841.73
Small(900MM) Point 6 829.61 4977.63
Supply and wiring of MCB controlled light point with FRLS PVC
1.2 insulated copper conductor cable in PVC conduit with surface /
recessed with all accesOSRies .
Primary (first) light point with 2X2.5sq.mm+1X2.5 sq.mm FRLS PVC
i) insulated copper conductor cable controlled by a 6A MCB (MCB Nos 20 1680.00 33600.00
cost not to be included here).
Secondary (loop) light point with 2X1.5sq.mm+1X1.5 sq.mm FRLS
ii) PVC insulated copper conductor cable looped to first point and so Nos 112 840.00 94080.00
Recessed wiring for 5 / 6 Amp socket outlet with 2 X 1.50 sq.
mm FR PVC insulated Single Core Multi standard Copper
Conductor of ISI marked with 20 mm dia non-metallic PVC flexible
conduit with 5 Amp, 250 Volt piano type swich ISI marked, Phenolic
laminated sheet of suitable size ISI marked MS box and earthing
point with 1 X 1.50 sq. mm FR PVC insulated Single Core Multi
standard Copper Conductor for loop earthing etc. as required, as
per direction of engineer in charge.
Short Nos 412 403.75 166345.36
Recessed wiring for 15 / 16 Amp socket outlet with 2 X 4.00 sq.
mm FR PVC insulated Single Core Multi standard Copper
Conductor of ISI marked with 20 mm dia non-metallic PVC flexible
conduit with 5 Amp, 250 Volt piano type swich ISI marked, Phenolic
1.4 laminated sheet of suitable size ISI marked MS box and earthing
point with 1 X 2.50 sq. mm FR PVC insulated Single Core Multi
standard Copper Conductor for loop earthing etc. as required, as
per direction of engineer in charge.
Long Nos 27 555.58 15000.65
Recessed wiring for Geyser 20 Amp socket outlet with 2 X 4.00
sq. mm FR PVC insulated Single Core Multi standard Copper
Conductor of ISI marked with 20 mm dia non-metallic PVC flexible
conduit with 5 Amp, 250 Volt piano type swich ISI marked, Phenolic
1.5 laminated sheet of suitable size ISI marked MS box and earthing Nos 40 730.13 29205.12
point with 1 X 2.50 sq. mm FR PVC insulated Single Core Multi
standard Copper Conductor for loop earthing etc. as required, as
per direction of engineer in charge.
Recessed wiring for AC 20 Amp socket outlet with 2 X 6.00 sq.
mm FR PVC insulated Single Core Multi standard Copper
Conductor of ISI marked with 20 mm dia non-metallic PVC flexible
conduit with 5 Amp, 250 Volt piano type swich ISI marked, Phenolic
laminated sheet of suitable size ISI marked MS box and earthing
point with 1 X 2.50 sq. mm FR PVC insulated Single Core Multi
standard Copper Conductor for loop earthing etc. as required, as
per direction of engineer in charge.
Recessed wiring to Sub-Main in 2 X 2.50 sq. mm FR PVC insulated
Single Core Multi standard Copper Conductor of ISI marked with 20
mm dia non-metallic PVC heavy duty flexible conduit with 1.60 mm
thick, along with 1 X 1.50 sq. mm FR PVC insulated Single Core
Multi standard Copper Conductor as earth wire as required as per
direction of Engineer-in-Charge.
Total Carried to Summary 1067366.79
SUB-HEAD II :- CONDUITING FOR TELEPHONE, INTERCOM &
CONDUITING FOR TELEPHONE, INTERCOM & DATA
Supplying and fixing of following sizes of medium class PVC conduit
along with accesOSRies in surface/recess including cutting the wall
and making good the same in case of recessed conduit as required.
TELEPHONE/ INTERCOM WIRING
Supplying and drawing following pair 0.5 mm dia FRLS PVC
2.2 insulated annealed copper conductor, unarmored telephone cable
in the existing surface/ recessed steel/ PVC conduit as required.
TELEPHONE TAG BLOCK
Supply, installation, testing & commissioning of telephone tag
blocks with 'KRONE" terminal connectors fixed in 16G powder
2.3 coated, hinged, lockable door, sheet steel enclosure including civil
work such as chase cutting, fixing/ concealing the box and making
good as required including terminations:
i. 10 pair tele tag block No. 8 2240.00 17920.00
TELEPHONE / INTERCOM OUTLET - MODULAR TYPE
Supplying and fixing telephone socket outlet piano type ISI marked
2.4 on the existing switch board / cover including connections etc as
requird.
i. Telephone socket outlet Nos. 42 44.32 1861.44
OUTLET BOXES FOR TELEPHONE / INTERCOM OUTLET
Supplying and fixing following size/ modules, GI box alongwith
2.5 modular base & cover plate for modular switches in recess etc. as
required.
i. 1 or 2 Module each 42 196.00 8232.00
CCTV SYSTEM
Supply, installation, testing and commissioning of UL Listed, 1.3
megapixel (1280 x 960) high resolution IR Bullet Camera, 1/3”
Progressive scan CMOS, [email protected], AGC ON. 0 Lux with IR on,
H.264 / MPEG4 / MJPEG, Dual stream, Bit rate 32 Kbps-16Mbps,
2.8 Standard IP66, 12 VDC ± 10%, PoE (802.3af), 4/6mm lens or Nos. 5 4745.44 23727.20
equivalent high definition,IR range 20-30 mtr, motion detection, with
ONVIF,SIP supported, connectors complete as required IR Bullet
type for mounting recessed in false ceiling or mounted on wall
complete as per tender specifications required.
Supply, installation, testing and commissioning of UL Listed, 1.3
megapixel (1280 x 960) high resolution Dome Camera,1/3”
Progressive scan CMOS, 0.2 O 0 Lux with IR on, 3.6/4 mm lens or
equivalent high definition, motion detection,120dB wide dynamic
range, H.264 / MPEG4 / MJPEG, Dual stream, Bit rate 32 Kbps-
16Mbps, 12 VDC ± 10%, PoE (802.3af), with ONVIF,SIP
supported,connectors complete as required in dome shape fixed
type for mounting recessed in false ceiling
Supply, installation, testing & commissioning of 16 Channel NVR
with embedded technology, capable of real time viewing and
2.10 recording at 4CIF with built in DVD/CD writer. Vendor to consider Nos. 3 18511.36 55534.08
storage for 30 days continuous recording. Vendor to submit storage
calculation sheet
Supply & Installation of 32" CCTV LED monitor capable of
2.11 accepting S - video as well as composite video signal (Make : Nos. 2 9775.36 19550.72
Interlogix / Americal Dynamics / SONY)
Supply & Installation of HDD, Rack, Chasis, Unit and AccesOSRies
2.12 for above components Set 2 8257.65 16515.30
Wiring for circuit/ submain wiring alongwith earth wire with the
2.13 following sizes of FRLS PVC insulated copper conductor, single
core cable in surface/ recessed steel conduit as required.uctor
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire RM 100 112.34 11233.60
Supplying and fixing of following sizes of steel conduit along
with accesOSRies in surface/recess including painting in case of
surface conduit, or cutting the wall and making good the same in
case of recessed conduit as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the
2.15 existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable RM 1265 34.72 43920.80
Total Carried to Summary 620580.58
3 SUB-HEAD III :- SUBMAIN DB/FINAL DISTRIBUTION BOARDS
Design, fabrication, assembling, wiring, supply, installation, testing
& commissioning of Final Distribution boards made out of pre-
treated and powder coated 1.2mm sheet steel and glazed steel door
in double door enclosure with MCB's / RCCB's mounted on din
channel, insulated prong bus bars rated for 100A and with separate
neutral and earth terminals and in 1,2,3 & 4 pole versions as asked
for or as required along with the cable end boxes on all sides of the
DB's as per the requirement or Cup-board layout suggested by
Architect/ Consultant.
GENERAL NOTES FOR MCB's & DB's:
MCB's shall be of minimum 10kA breaking capacity for 1 sec,
unless specified otherwise i.e. of capacity higher than 10KA.
Use 'B' curve MCB's for lighting & small power circuits, 'C' curve for
motor duty i.e. for window and split AC's etc. & 'D' curve for UPS
DB's i.e. for computers/ PC's circuit. Main incomer & outgoing circuit
nature of the circuit/ load.
Each DB shall have separate neutral links of rating not less than
100A for each phase. The main incoming neutral link shall be in
addition to three outgoing neutral links and shall be of 100A.
UPS DB's shall have a dedicated Earthing link fixed on insulated
supports, which will be in addition to body earth link.
All internal inter connecting wiring with in the DB's shall be PVC
insulated flexible copper conductor wires of adequate capacity as
per the current rating.
30mA DP ELCB's shall be used for each phase.
Inside each DB, a DB chart is to be fixed.
Exact MCB rating & category is to be calculated by the electrical
contractor based on the load of the circuit, its nature and fault
current.
3.1 L+PDB - (TPN -DB) SINGLE DOOR
Supply and fixing of single pole MCB/Tripple pole neutral, horizontal
type(as per requirement given) with sheet steel enclosure,
distribution board, on surface / recess, complete with tinned copper
i. bus bar, neutral bus bar, earth bar, din bar, detachable gland plate,
interconnection, phosphate and powder painted including earthing
etc. as required ( But with out MCB/ RCCB/ ISOLATOR)
8 way , Single Door EAC 4
LDB/PDB/CADB - (TPN -DB) SINGLE DOOR
Supply and fixing of single pole MCB/Tripple pole neutral(as per
requirement given) with sheet steel enclosure, distribution board, on
surface / recess, complete with tinned copper bus bar, neutral bus
ii. bar, earth bar, din bar, detachable gland plate, interconnection,
phosphate and powder painted including earthing etc. as required (
But with MCB/ RCCB/ ISOLATOR)
8 way , Single Door EAC 4
12 way ,Single Door EAC 12
EM.DB- (SPN -DB) DOUBLE DOOR
Supply and fixing of single pole MCB/Tripple pole neutral(as per
requirement given) with sheet steel enclosure, distribution board, on
surface / recess, complete with tinned copper bus bar, neutral bus
ii. bar, earth bar, din bar, detachable gland plate, interconnection,
phosphate and powder painted including earthing etc. as required (
But with MCB/ RCCB/ ISOLATOR)
12 way ,Double door EAC 4
SMDB-(TPN-DB) DOUBLE DOOR
Supply and fixing of Tripple pole MCCB with sheet steel enclosure,
sub main distribution board, metering options ,on surface / recess,
complete with tinned copper bus bar, neutral bus bar, earth bar, din
ii. bar, detachable gland plate, interconnection, phosphate and powder
painted including earthing etc.It should be fully enclosed tin plated
copper bus bar provides as required ( But with MCB/ RCCB/
ISOLATOR)
4 way , Double door EAC 4
8 way , Double door EAC 1
Total carried to summary 245157.49
SUB-HEAD IV :- CIRCUIT/ SUBMAIN WIRING/CABLES/SUB
MAIN CABLES
Recessed wiring to Sub-Main in 2 X 2.50 sq. mm FR PVC
insulated Single Core Multi standard Copper Conductor of ISI
marked with 20 mm dia non-metallic PVC heavy duty flexible
4.1 conduit with 1.60 mm thick, along with 1 X 1.50 sq. mm FR PVC
insulated Single Core Multi standard Copper Conductor as earth
wire as required as per direction of Engineer-in-Charge.
2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire RM 5246 97.69 512483.78
Recessed wiring to Sub-Main in 2 X 6.00 sq. mm FR PVC
insulated Single Core Multi standard Copper Conductor of ISI
marked with 25 mm dia non-metallic PVC heavy duty flexible
4.2 conduit with 1.60 mm thick, along with 1 X 2.50 sq. mm FR PVC
insulated Single Core Multi standard Copper Conductor as earth
wire as required as per direction of Engineer-in-Charge.
2 X 6 sq. mm + 1 X 2.5 sq. mm earth wire RM 1287 151.69 195226.90
Supplying and fixing of following sizes of medium class PVC conduit
along with accesOSRies in surface/recess including cutting the wall
and making good the same in case of recessed conduit as required.
4 X 10.00 sq. mm PVC INSULATED ALUMINUM CONDUCTOR
insulated 4 Core Multi standard AL. Conductor of ISI marked
with 32 mm dia non-metallic PVC heavy duty conduit with 1.60 mm
thick, along with 1 X 4 sq. mm FR PVC insulated Single Core Multi
standard copper Conductor as earth wire as required as per
direction of Engineer-in-Charge.
Supply , Install , Test , Commission 1100 V FRLS armoured cables
4.6 in trenches , cable trays , ducts , over bed of sand , clamped to wall
with suitable clamps.
FRLS with only outer sheath
Power Cables 4Cx6 Sq MM Copper RMT 181 88.03 15933.79
Power Cables 4x10 Sq MM Copper RMT 311 88.03 27377.95
Power Cables 4x16 Sq MM Copper RMT 122 88.03 10739.90
Power Cables 3 1/2x25 Sq MM Al RMT 113 88.03 9947.62
Power Cables 3 1/2x 35 Sq MM Al RMT 74 92.62 6854.18
Power Cables 3 1/2x50 Sq MM Al RMT 218 92.62 20192.03
Power Cables 3 1/2x70 Sq MM Al RMT 61 92.62 5650.06
Power Cables 3 1/2x240 Sq MM Al RMT 50 97.22 4860.80
Power Cables 3 1/2x300 Sq MM Al RMT 232 97.22 22554.11
Cable termination of the following PVC armoured cable including
supplying & fixing of crimping lugs , glands . Siemens type gland
upto 70 Sqmm & above flange type glands , double compression
glands for breaded cable. All glands should be earthed.
Power Cables 4x6 Sq MM Copper SET 30 337.12 10113.60
Power Cables 4x10 Sq MM Copper
Power Cables 4x16 Sq MM Copper
Power Cables 3 1/2x25 Sq MM Al
Power Cables 3 1/2x 35 Sq MM Al
Power Cables 3 1/2x50 Sq MM Al
Power Cables 3 1/2x70 Sq MM Al
Power Cables 3 1/2x240 Sq MM Al
Power Cables 3 1/2x300 Sq MM Al
Supply & Install perforated cable tray as per approved makes
4.8 complete with the supports , fist plates to be supported from the
ceiling. Supporting material to be taken here.
150x50 mm RMT 515 383.04 197265.60
Total Carried to Summary 1742126.39
5 SUB HEAD V :- LIGHT FIXTURE & FAN
Supply and fixing of recess/ Surface/ Pendent mounting round 10 to
12 Watt LED Down Lighter having Powder coated diecast
5.1 aluminium housing with heat sink, diffuser/ Reflector and driver set Nos 75 282.24 21168.00
complete in all respect.
Supply and fixing of LED Tube Light with batten suitable for up to 1
5.2 X 20 watt LED tube light complete including tube etc on surface Nos. 28 1046.64 29305.92
complete in all respect.
Supply and Fixing of 18W led downlighter & fixture with all
5.4 interconnections of approved makes and fixing arrangements as Nos. 452 1125.04 508518.08
required
Supply and Fixing of 10W Mirror Light & fixture with all
5.5 interconnections of approved makes and fixing arrangements as Nos. 43 448.00 19264.00
required
Supply and Fixing of 36W Square Light & fixture with all
5.6 interconnections of approved makes and fixing arrangements as Nos. 83 2551.92 211809.36
required
Supply, Erection and testing of exhaust fan on the existing hole with
5.7 suitable size of rag bolts, nuts and washers etc., complete in all Nos. 36 1512.00 54432.00
respect.
Supply, Installation, Testing & Commissioning of 1200mm Ceiling
Supply and Fixing of 7W led uplighter & fixture with all
5.9 interconnections of brackets approved makes and fixing Nos. 15 4984.00 74760.00
arrangements as required
Total carried to summary 1911263.76
6 SUB HEAD VI :- ELECTRICAL PANEL
Scope shall include all Design , Supply , Install , Test , Commission
( at factory & Site ) of switch boards .
Secondary injection testing for the main MCCB's to be conducted at
site. Factory test certificates for all other MCCB's , MCB . All
components to be provided.
Calculations for the Bus Bar to be submitted. BMS Points as per
attached schedule to be provided. Marshalling box for BMS.
All ACB/MCCB/MCB's to be as per the current Discrimination .
Discrimination study report needs to be submitted prior to
manufacturing of panel.Breakers above should be High end
Electronics release & communication port etc.All MCCB to have
necessary acesOSRies such as shunt trip .Electrical and
mechanical interlocking systems should have to be consider on
panel (PLC/SCADA/CONTROLLER should have to be consider as
per requirements)
LT Panel -1 generally described below & as shown on the relevant
6.1 drawings along with all the protection to make the panel fool proof. No.s 1 1044064.00 1044064.00
Design , fabrication , assembling , wiring , supply , installation ,
testing and commissioning of panel fabricated out of 14 Gauge
CRCA sheet steel in cubical compartmentalized free standing floor
mounted , dust and vermin proof with reinforcement of suit
INCOMER
1000 Amp 4 Pole ACB Thermal Magnetic Release with short
circuit,Earth fault,overload with on / off Pot free contact for BMS
connectivity. 36 KA Breaking capacity,
630 Amp 4 Pole MCCB Thermal Magnetic Release with short
circuit,Earth fault,overload with on / off Pot free contact for BMS
connectivity. 36 KA Breaking capacity,
Metering as described below- 1 Lot
Indicating lamps for three phases with toggle switch for on / off at
incomer & outgoing..
1000/5A Current transformer to be used shall be accuracy class 0.5
with ratio.( 1000 / 5 Amps.) ( CT shorting link to be provided )for
1000a YPN MCCB
600/5A Current transformer to be used shall be accuracy class 0.5
with ratio.( 1000 / 5 Amps.) ( CT shorting link to be provided )for
1000a YPN MCCB
Necessary protection for the metering.
Load Manger for monitoring minimum following parameters to be
provided for all the load managers listed in all panels. Load
Manager should be compatable with BMS system , necessary
interface / software to be provided with comm port.
Power Factor
Frequency.
Voltages of all the three phases.
Current of all the three phases.
Measurement of Harmonics current of all the phases
TVSS 100 , 65 Ka with necessary protections 01
Bus Bars
1000 Amp 4P Aluminum insulated busbars
OUTGOING MCCB
630 Amp 4P MCCB , 35 KA- 02 Nos
160 Amp 4P MCCB , 35 KA- 06 Nos
63 Amp 4P MCCB , 35 KA- 02 Nos
32 Amp 4P MCCB , 35 KA- 06 Nos
100 Amp 4P MCCB , 35 KA- 01 Nos
250 Amp 4P MCCB , 35 KA- 02 Nos
AC Outgoing Section
Incomer - 125 Amp 4P MCCB , with shunt trip , Load Manager ,
Indicating lamps - 01 Nos
Outgoing - 63 Amp 4P MCB "C" curve - 7 Nos
Bus coupler - 1000Amp 4 Pole MDO ACB with thermal Magnetic
release
Detuned Capacitor section for Main Panel. All metal work to be
Necessary arrangement with all controls to make it fully functional.
Incomer - 630 Amp TP MCCB 35 KA breaker with Al bus bar.
Outgoing
160 Amp TP MCB with Ammeter , Contactor , Indicating lamps ,
On/Off push button. With 50 KVAR Capacitor - 1Nos.
300 Amp TP MCB with Ammeter , Contactor , Indicating lamps ,
On/Off push button. With 100 KVAR Capacitor - 1Nos.
UPS O/P Panel -1 generally described below & as shown on the
6.3 relevant drawings along with all the protection to make the panel No.s 2 23128.00 46256.00
fool proof.
INCOMER
100 Amp 4 Pole MCCB with short circuit,Earth fault,overload with
on / off Pot free contact for BMS connectivity. 36 KA Breaking
capacity,
OUTGOING MCCB
32 Amp 4P MCCB , 36 KA- 04 Nos
M/C Room Panel -1 generally described below & as shown on the
6.4 relevant drawings along with all the protection to make the panel No.s 1 67401.60 67401.60
fool proof.
INCOMER
125 Amp 4 Pole MCCB with short circuit,Earth fault,overload with
on / off Pot free contact for BMS connectivity. 36 KA Breaking
capacity,
OUTGOING MCCB
63 Amp 4P MCCB , 35 KA- 06 Nos
SITC of UPS ,battery back up has to be consider 10-15min battery
back up time consider the battery rack with all as per requirements
6.5 generally described below & as shown on the relevant drawings
along with all the protection to make the panel fool proof.
6KVA UPS No.s 2 112560.00 225120.00
Total carried to summary 1382841.60
7 SUB HEAD VII :- EARTHING
Supply , Install , test commission Earthing system as described
below complete with necessary hardware , mounting etc to complete
the installation.
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick
including accesOSRies, and providing masonry enclosure with
cover plate having locking arrangement and watering pipe of 2.7 set 9 5827.69 52449.23
metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick
including accesOSRies, and providing masonry enclosure with
cover plate having locking arrangement and watering pipe of 2.7 set 4 2763.15 11052.62
meter long etc. with charcoal/ coke and salt as required.
32 x 6mm G.l strip. RM 414 104.79 43382.64
25 x 6mm copper strip. RM 200 623.40 124680.56
25 x 6mm G.I strip. RM 46 97.20 4471.09
Total carried to summary 236036.13
8 EXTERNAL
"Supply and Transportation, Installation, Testing and
Commissioning of copper wound Transformers 11/0.433 KV, Three
Phase, 50 Hz, DYN 11, ONAN type, standard accesOSRies,
winding temperature rise of 45°C/40°C first fill oil, having
permissible total loss values not exceeding 7.5% of the maximum
total loss values for 11 KV as per Energy Efficiency Level - 2 at
basic Insulation level conforming to ISS 2026 (Part- I to Part - II),
latest ammended and IS 1180 Part-I : 2014 described as above with
Cable box on HV side and Bus duct on LV Side , ON load Tap
changer(OLTC) With Remote Tap Change Cicuit (RTCC) &
Automatic Voltage Regulator (AVR) etc., complete and as per the
following continuous rating.
8.2.1 500KVA Transformer No.s 1 1769600.00 1769600.00
8.3 11 KV HT Panel
Supply and installation of HT 11 KV, 3 phase, 50 Hz totally enclosed
metal clad switchgear complete with Vacuum circuit breaker having
rupturing capacity 350 MVA, overload and earth fault protection, Each 1 392000.00 392000.00
ammeter, voltmeter and of rating upto 630 amp (three incoming, two
bus coupler & three outgoing VCB panel )
Incomer : Transformer (500 kVA Transformer )
1 No., 630A 50kA, 4P, EDO, ACB with:
230V, AC spring charging motor
230V, AC closing coil
24V, DC shunt trip coil
4 NO + 4NC Aux. contacts
In built trip LED's
Breaker control switch
8.4 CABLE TERMINATION 11 KV HT (HEAT SHRINKABLE)
Supply and fix cable jointing kit for 11 KV grade cable for in door
termination, heat shrink type, joint complete with jointing material
and accesOSRies suitable for3 core XLPE, armoured, Al conductor
cable of size 240 sqmm to 300 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE
power cable of 11 KV grade of 240SQ.mm under the ground as per
8.4.2 requirements near the to the pole - transformer and necessary Nos 100 53216.66 5321665.66
requiretnts has to be consider.
8.5 LIFTS
Supply,Installation,Testing and Commissioning of Electric Traction
Bed cum Passenger Lift with
• Rated capacity :- 10 Passenger/1360Kg
• Floors :- G+1 floor
• Travel :- 10 to 12mtrs
• Location of Lift Machine:- with Machine Room
• Rated speed :- 1.0mps VS
• Doors type :- COPO/TOPO Doors with frame having clear
opening of 1200 mm wide x 2000 mm high made from SS 304
grade sheet of 1.5mm, thick in hairline finish for car and all landing
doors with SS door architraves/frames
• Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick Each
with hairline finish with frame made from MS girders, bracing of
adequate size with minimum safety factor of 5, with Toe Guard
Apron, with necessary false ceiling with adequate LED lights,
blower/fan for ventilation & SS chequered plate flooring, handrails,
mirror, emergency light etc.
• COP with SS face plate having metallic push buttons with Braille
Code & luminous indicator around button with FPI, scrolling UP/DN
LED indicator & with/without attendant key switch, OWD with audio-
visual alarm, VAS in Telugu & English with intercom system with
telephone instrument in Lift car, LMR & FCC/ground floor.
• Clear Car size of 1300mm/1400mm wide x 2400mm deep x
2200mm high
Supply, Installation, Testing & Commissioning of 4.5 mtr High
8.6 Single arm Decorative Pole of approved make Nos 15 14000.00 210000.00
Supply and fixing of LED Street light Fitting having die cast
aluminium body and diffuser with driver set suitable for 45 watt to 50
8.8 Watt. Confirming to IP 65 and above protection complete in all Nos 15 5532.80 82992.00
respect. CAT. AAA
Solar Light
Supply, Installation, Testing & Commissioning of Solar PV stand
with Street 20W LED Lighting System comprising of one75 Wp
SPV module, one 12 V,75 Ah Tubular Plate sealed maintenance
free VRLA Gel Battery, one White LED luminary of 20W with in-built
inverter, Charger, dusk to dawn circuit for automatic switching on &
off at dusk to dawn, automatic dimming circuit (automatic/optional)
based on real time clock for full bright operation during first six
hours and half bright operation for rest hours, 4.5M pole, one charge-
regulator, module mounting structure, Pole mounted Battery box,
cables and other fittings along with 5 (five) years guarantee /
warranty period (25 years for SPV Module).
Supply installation, testing & commissioning of Access Controlled
Boom Barrier (6 M) for Ground floor Entry and Exit for Vehicle with
Long Range Reader mounted on the padestal.
Supply and fixing of geyser of 25ltr capacity with all the rquirements
Total carried to summary 14,357,111
Grand Total 21,562,483
Grand Total 21,562,483
BILL OF QUANTITIES
S.N TOTAL
DESCRIPTION UNIT RATE AMOUNT
1 SANITARY FIXTURES
Providing and fixing white vitreous china pedestal type
water closet (European type) with seat and lid, 10 litre low
level white vitreous china flushing cistern & C.P. flush bend
with fittings & C.I. brackets, 40 mm flush bend, overflow
arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete,
including painting of fittings and brackets, cutting and
making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid Each 57 5064.64 288,684
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible
tube upto1 metre long with S.S. triangular plate to
Eureopean type W.C. of quality and make as approved by
Engineer - in - charge.
1.4 Providing and fixing wash basin with C.I. brackets, 15 mm
C.P. brass pillar taps, 32 mm C.P. brass waste of standard
pattern, including painting of fittings and brackets, cutting
and making good the walls wherever require:
White Vitreous China Wash basin size 550x400 mm with a
pair of 15 mm C.P. brass pillar taps
1.5 Providing and fixing wash basin with C.I. brackets, 15 mm
dia CP Brass single hole basin mixer of approved quality
and make, including painting of fittings and brackets, cutting
and making good the walls wherever required:- (a) White
Vitreous China Wash basin size 550x400 mm with a 15 mm
CP Brass single hole basin mixer
1.6 Providing and fixing white vitreous china flat back or wall
corner type lipped front urinal basin of 430x260x350 mm
and 340x410x265 mm sizes respectively with automatic
flushing cistern with standard flush pipe and C.P. brass
spreaders with brass unions and G.I clamps complete,
including painting of fittings and brackets, cutting and
making good the walls and floors wherever required :
One urinal basin with 5 litre white P.V.C. automatic flushing
cistern
S.N TOTAL
DESCRIPTION UNIT RATE AMOUNT
1.7 Providing and fixing brass bib cock of approved quality :
15 MM Nominal Bore Each 11 291.20 3,203
1.8 Providing and fixing C.P. brass angle valve for basin mixer
and geyser points of approved quality conforming to
15 MM Nominal Bore Each 353 511.84 180,680
1.9 Providing and fixing PTMT grating of approved quality and
colour.
125 mm nominal dia with 25 mm waste hole Each 101 49.28 4,977
Providing and fixing adjustable type wash basin for
1.10 handicap toilet complete with brackets, tracks , waste pipes Each 1 9520.00 9,520
and other accessories complete as required.
Providing and fixing 2 Nos. support arms and backrest to
1.11 mounted on the track (vertically and laterally) for handicap Each 1 5040.00 5,040
toilet complete as required.
Providing and fixing raised toilet seat with cover for
handicap toilet.
Providing & fixing of 450mm long stainless steel grab bar
as per directions of Engineer-Incharge.
Providing and fixing C.P. brass shower rose with 15 or 20
mm inlet :
100 mm diameter Each 34 146.72 4,988
Providing and fixing CP Brass Single lever telephonic
1.15 wall mixer of quality & make as approved by Engineer in
charge.
(a) 15 mm nominal dia Each 34 5885.60 200,110
Providing and Fixing standard size Chromium Plated brass
or glazed porcelain Toilet paper holder fixed to woden
plugs with Chromium Plated brass screws complete as per
specification.
CP Toilet paper holder Each 58 256.59 14,882
S.N TOTAL
DESCRIPTION UNIT RATE AMOUNT
Providing and Fixing standard sized Chromium Plated
brass towel rail complete with Chromium Plated brass
brackets fixed to wooden plugs with Chromium Plated
brass screws, complete as per specification.
Chromium Plated brass towel rail Each 34 1037.57 35,277
Providing and Fixing standard sized Chromium Plated
1.18 brass towel ring fixed to wooden plugs with Chromium
Plated brass screws, complete as per specification.
Chromium Plated brass towel ring Each 34 554.18 18,842
Providing and Fixing (a) Liquid Soap Container – Glass
container or Plastic container with Chromium Plated brass
lid and brackets fixed to wooden plugs with Chromium
Plated brass screws or (b) Chromium Plated brass soap
dish complete with Chromium Plated brass brackets fixed
to wooden plugs with Chromium Plated brass screws or (c)
white glazed tooth brush holder fixed to wooden plugs with
Chromium Plated brass screws as per specification.
CP soap holder Each 34 100.80 3,427
CP tooth brush holder Each 34 100.80 3,427
CP double coat hook Each 34 252.00 8,568
Providing & Fixing 600mm x 450mm bevelled edge mirror
of superior glass mounted on 6mm thick A.C sheet or
1.20 plywood sheet and fixed to wooden plugs with chromium
plated brass screws and washers complete as per
specification
600mm x 450mm bevelled edge mirror Each 34 683.31 23,233
Rectangular shape 1500x450 mm Each 8 1266.16 10,129
Providing & Fixing standard sized glass-shelf with
Chromium Plated brass brackets and guard rails complete,
fixed to woden plugs with Chromium Plated brass screws
as per specification.
600x120 mm glass shelf with anodised aluminium angle
frame, C.P. brass Each 34 316.40 10,758
brackets and guard rail of standard size
TOTAL "SANITARY FIXTURES "CARRIED TO
SUMMARY
SOIL, WASTE, VENT AND RAIN WATER PIPES &
FITTINGS
S.N TOTAL
DESCRIPTION UNIT RATE AMOUNT
Providing and fixing on wall face unplasticised Rigid PVC
soil, waste and rain water pipes conforming to IS : 13592
Type A, including jointing with seal ring conforming to IS:
5382, leaving 10 mm gap for thermal expansion, (i) Single
socketed pipes
110mm diameter Metre 722 206.86 149,356
Providing and fixing to wall or ceiling and floor rigid UPVC
pipes class IV (8 kgf/cm²)/class III (6kgf/cm²) conforming to
IS:4985/2000 and pipe fittings of the following nominal bore
with clamps including making good the wall, ceiling and
floor all complete as per specification
40 mm diameter Metre 79.5 99.23 7,889
50 mm diameter Metre 65.4 138.88 9,083
Fixing 100mm size ‘P’ or ‘S’ trap (with horn or without
horn) for water closet squatting pan including jointing the
trap with pan in cement mortar (1:1) as per specification.
100mm dia SCI 'P' trap Each 58 375.20 21,762
Providing and fixing on wall face unplasticised-PVC
moulded fittings / accessories for unplasticised Rigid PVC
rain water pipes conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS : 5382, leaving 10
mm gap for thermal expansion
Bend 87.5° Each 43 115.92 4,985
Providing and fixing UPVC Clean Out plug (FCO & COP)
with end cap for opening, complete in all respects.
100mm dia Each 20 1176.00 23,520
150mm dia Each 5 1534.40 7,672
Providing and making Khurras with average minimum
thickness of 5cm Cement Concrete 1:2:4 (1 Cement : 2
Coarse Sand : 4 Graded Stone Aggregate 20 mm nominal
size) over PVC sheet 1 m x 1 m (PVC 400 microns min.
thickness), finished with 12mm Cement Plaster 1:3 (1
Cement : 3 Coarse Sand, admixed with waterproofing
compound) and a coat of neat cement, rounding the edges
and making & finishing the outlet complete.
S.N TOTAL
DESCRIPTION UNIT RATE AMOUNT
Khurra Size 450 x 450mm, for 150mm dia outlet with 5mm
thick circular/square vertical C.I grating.
TOTAL"SOIL, WASTE, VENT AND RAIN WATER PIPES
& FITTINGS "CARRIED TO SUMMARY
3 WATER SUPPLY SYSTEM (Internal & External)
3.1 Providing and fixing to wall or ceiling and floor galvanized
mild steel tubes (medium grade) conforming to IS:
1239/2004, Part-1 of the following nominal bore, tube
fittings and clamps including making good the wall, ceiling
and floor, testing all complete as per specification
20mm diameter Metre 101 152.54 15,407
25mm diameter Metre 145.5 216.50 31,500
40mm diameter Metre 20 314.83 6,297
50mm diameter Metre 160 433.10 69,297
3.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes conforming to IS:15778,having thermal stability for
hot & cold water supply, including all CPVC plain & brass
threaded fittings including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings
with one step CPVC solvent cement and testing of joints
complete as per direction of Engineer-in-Charge
15mm diameter Metre 233 124.66 29,045
20mm diameter Metre 175 148.29 25,950
25mm diameter Metre 55 193.54 10,644
Providing and fixing thermal insulation over hot water
pipes in chase having with 9mm thick ' nitrile rubber
insulation ' tube type thermal insulation tubing, a
elastomeric flexible material having hermetic blister closed
cell structure of expanded having density of 60-90 Kg/m3
over pipes of following sizes including all required
accessories complete as per Manufactuer's specifications
and finishing it as per site requirement with rough Cement
Plaster.
For 15mm nomenal bore Dia or Equivalent Metre 153 134.40 20,563
Fixing of Brass Ball Valve (Horizontal plunger type)
conforming to IS 1703-1977 as per specification complete
S.N TOTAL
DESCRIPTION UNIT RATE AMOUNT
High pressure/Low pressure with copper or PVC floats of
the following nominal bore
20mm diameter Each 39 403.20 15,725
25mm diameter Each 23 537.60 12,365
40mm diameter Each 4 1164.80 4,659
50mm diameter Each 3 1814.40 5,443
Providing and fixing ball valve (brass) of approved quality,
High or low pressure, with plastic floats complete
20 mm dia nominal bore Each 1 371.84 372
3.7 Constructing masonry Chamber 60x60x75 cm inside, in
brick work
in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice
valve,
with C.I. surface box 100mm top diameter, 160 mm bottom
diameter
and 180 mm deep ( inside) with chained lid and RCC top
mix (1 cement : 2 coarse sand : 4 graded stone aggregate
nominal size ) , i/c necessary excavation, foundation
concrete 1:5:10
(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm
nominal
size) and inside plastering with cement mortar 1:3 (1
cement : 3
coarse sand) 12 mm thick, finished with a floating coat of
neat cement
complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of
class designation 7.5
TOTAL"WATER SUPPLY SYSTEM (Internal & External)
"CARRIED TO SUMMARY
4 DOMESTIC WATER RISER PUMP
SUB TOTAL "DOMESTIC WATER PUMP" CARRIED TO
SUMMARY
5 SEWERAGE & DRAINAGE SYSTEM
S.N TOTAL
DESCRIPTION UNIT RATE AMOUNT
5.1 Excavation of trenches of required width for pipes, including
dressing of sides, ramming of bottom, depth upto 1.5m
including getting out the excavated soil, and then returning
the soil as required, in layers not exceeding 20cms depth
including consolidating each deposited layers by
ramming, watering, etc. and disposing of surplus excavated
soil as directed outside the site to the approved dumping
ground.
Pipes exceeding 100mm dia but not exceeding 300mm dia. Metre 950 268.80 255,360
Laying (to level or slopes) and jointing with rubber rings pre-
cast reinforced socket and spigot concrete pipes Class NP-
2 conforming to IS:458 - 2003 suitable for rubber ring roll on
joint of the following internal diameter as per specification
complete.(Earthwork in trenches to be measured and paid
for separately)
150mm diameter Metre 650 493.81 320,975
200mm diameter Metre 300 590.80 177,240
5.3 Providing and fixing square-mouth S.W. gully trap class
SP-1 complete with C.I.grating brick masonry chamber with
water tight C.I. cover with frame of 300x300 mm size
(inside) the weight of cover to be not less than 4.50 kg and
frame to be not less than 2.70 kg as per standard design
180x150 mm size P type Each 25 1476.05 36,901
Constructing brick masonry Road gully chamber
45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement
: 4 coarse sand ) with precast R.C.C. vertical grating
complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of
class designation 7.5
Constructing manholes with R.C.C top slab in (1:2:4) mix,
foundation concrete (1:4:8), inside plaster 12mm thick with
cement mortar (1:3) finished with neat cement punning,
12mm thick outside cement plaster (1:3), brick work with
K.B bricks having crushing strength not less than
75kg/cm² with dimensional tolerance ± 8 percent in cement
mortar (1:5), cement concrete (1:2:4) finished smooth using
12mm size h.g chips, earthwork in excavation in all kinds of
soil and refilling the cavity around the chamber complete as
per specification.
Plain Manholes inside size 900mm x 800mm and
450mm deep - Type A
S.N TOTAL
DESCRIPTION UNIT RATE AMOUNT
TOTAL "SEWERAGE & DRAINAGE SYSTEM "CARRIED
TO SUMMARY
NAME OF PROJECT: CONSTRUCTION OF CIRCUIT HOUSE AT ROURKELA IN SUNDARGARH DISTRICT OF
ODISHA
HORTICULTURE BOQ
Description Unit Qty. Rate Amount
Trenching in ordinary soil up to a depth of 60 cm including removal and
stacking of serviceable materials and then disposing of surplus soil, by
spreading and neatly levelling within a lead of 50 m and making up the
trenched area to proper levels by filling with earth or earth mixed with
sludge or / and manure before and after flooding trench with water
(excluding cost of imported earth, sludge or manure).
Supplying and stacking of good earth at site including royalty and carriage
2 upto 5 km lead complete (earth measured in stacks will be reduced by Cum 1910.74 487.09 930699.86
20% for payment).
Supplying and stacking sludge at site including royalty and carriage upto 5
3 km lead complete (sludge measured in stacks will be reduced by 8% for Cum 955.37 241.92 231123.44
payment).
Supplying and stacking at site dump manure from approved source,
including carriage upto 5 km lead complete (manure measured in stacks
will be reduced by 8% for payment) :
4.1 Screened through sieve of I.S. designation 20 mm Cum 125.00 163.86 20482.00
4.2 Screened through sieve of I.S. designation 16 mm Cum 125.00 190.62 23828.00
4.3 Screened through sieve of I.S. designation 4.75 mm Cum 125.00 219.86 27482.00
5 Rough dressing the trenched ground including breaking clods. Sqm 5459.27 0.84 4585.78
Uprooting weeds from the trenched area after 10 to 15 days of its flooding
with water including disposal of uprooted vegetation.
Mixing earth and sludge or manure in the required roportion specified or
directed by the Officer-in-charge
Spreading of sludge, dump manure and/or good earth in required
8 thickness as per direction of officer-in-charge (cost of sludge, dump Cum 3241.11 37.52 121606.60
manure and/ or good earth to be paid separately).
maintenance of the lawn for 30 days or more till the grass forms a thick
lawn, free from weeds and fit for mowing including supplying good earth, if
needed (only good earth shall be paid seperately)
9.1 In rows 5 cm apart in both directions. Sqm 3275.56 42.34 138674.07
9.2 With grass Turf . Sqm 2183.71 66.86 146011.32
Renovating lawns including weeding, cheeling the grass, forking the
ground, top dressing with sludge or manure, mixing the same with forked
soil, watering and maintaining the lawn for 30 days or more till the grass
10 forms a thick lawn free from weeds and fit for mowing and disposal of Sqm 1000.00 24.42 24416.00
rubbish as directed, including supplying good earth if needed but
excluding the cost of sludge or manure (the good earth shall be paid for
separately).
Edging with bricks laid dry length wise, including required excavation,
refilling, consolidating with hand packing and spreading surplus earth
11 Metre 150.00 32.14 4821.60
neatly within a lead of 50 m : With Common burnt clay F.P.S (non
modular) bricks of Class designation 7.5 .
TOTAL AMOUNT 1905164.00
TOTAL AMOUNT 1905164.00
SUPPLY OF PLANTS : SCHEDULE OF QUANTITIES
The rate of the following items include for
supply of plants (caliper measured 900mm
above root bulb) as specified, transportation to Specifications
site as follows:
S.No. Code Botanical name Unit Qty Rate Amount
Qty in
Hedge Unit
1 D DURANTA Each 156.60 24.14 3779.7
TOTAL 3779.7
FLOWER PLANT Unit Qty
2 MARIGOLD No. 168.32 21.28 3581.8
3 ROSE No. 168.32 95.20 16024.1
TOTAL 19605.91
HERBAL PLANT Unit Qty
4 BR BACOCA MONIERY No. 168.32 67.20 11311.1
5 OP CONVOLVULUS PLURICAULIS No. 168.32 61.60 10368.5
TOTAL 21679.62
NET TOTAL 45,065
NAME OF PROJECT: CONSTRUCTION OF CIRCUIT HOUSE AT ROURKELA IN SUNDARGARH DISTRICT OF
ODISHA
BILL OF QUANTITIES (For Road work)
DESCRIPTION OF ITEM QUANTITY UNIT RATE AMOUNT
Preparation and consolidation of sub grade with power road
roller of 8 to 12 tonne capacity after excavating earth to an
average of 22.5 cm depth, dressing to camber and
1 consolidating with road roller including making good the 2225.04 Sqm 87.36 194379.18
undulations etc. and re-rolling the sub grade and disposal of
surplus earth
with lead upto 50 metres.
Construction of granular sub-base by providing close graded
Material conforming to specifications, mixing in a mechanical
mix plant at OMC, carriage of mixed material by tippers to
work site, for all leads & lifts, spreading in uniform layers of
specified thickness with motor grader on prepared surface
and compacting with vibratory power roller to achieve the
desired density, complete as per specifications and directions
of Engineer-in-Charge.
With material conforming to Grade-III (size range 26.5 mm to
0.075 mm ) having CBR Value-20
Construction of un-reinforced, dowel jointed, plain cement
concrete pavement over a prepared sub base with 43 grade
cement @ 400 kg per cum, coarse and fine aggregate
conforming to IS 383, maximum size of coarse aggregate not
exceeding 25 mm, mixed in a batching and mixing plant as
per approved mix design, transported to site, laid with a fixed
form or slip form paver, spread, compacted and finished in a
continuous operation including provision of contraction,
expansion, construction and longitudinal joints, joint filler,
separation membrane, sealant primer, joint sealant,
debonding strip, dowel bar, tie rod, admixtures as approved,
curing compound, finishing to lines and grades as per
drawing and as per Clause 602 of MoSRT&H Specifications
for Road & Bridge works (4th Revision)
Providing and laying at or near ground level factory made
kerb stone of M-25 grade cement concrete in position to the
required line, level and curvature, jointed with cement mortar
1:3 (1 cement: 3 coarse sand), including making joints with or
without grooves (thickness of joints except at sharp curve
shall not to more than 5mm), including making drainage
opening wherever required complete etc. as per direction of
Engineer-in-charge (length of finished kerb edging shall be
measured for payment). (Precast C.C. kerb stone shall be
approved by Engineer-in-charge).
Road Page 12 of 87
Constructing brick masonry road gully chamber 50x45x60 cm
with bricks in cement mortar 1:4 (1 cement : 4 coarse sand)
5 including 500x450 mm pre-cast R.C.C. horizontal grating with
frame complete
as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Wall painting 2 coats with enamel paint of approved shade on
6 new work including one coat of primer to give an even shade 183.57 Sqm 148.96 27344.24
exculding cost of paint
Providing & Laying pebble wash flooring as design given in
architecture drawing under instruction of Engineer in Charge.
Providing M 20 nominal mix saucer drain with Hunch of Size
300 x 100mm using aggregates, cement, including earthwork
excavation 0.425m x 0.15m, PCC(1:5:10) bed 0.45m x
0.075mm, M 20 mix for saucer drain and plastering 12mm
thick Single Coat CM (1:5) for Exposed faces , and as
directed by the Engineer - in - charge including cost and
conveyance of all materials to site, all labour charges like
mixing of cement concrete, laying, curing, centring cahrges
overheads & contractor profit etc., complete for finished item
of work.
Providing and laying 500x500x40 mm thick Turf paver
(Turfpave XD) on 150 mm thick sub grade of compacted bed
of 20 mm thick nominal size stone aggregate and base
course and filling with 150 mm thick jamuna sand, including
spreading, well ramming, consolidating and finishing smooth
etc. all complete as per direction of Engineer-in-charge.
Providing and laying 60mm thick faciory made cement
concrete interlocking paver block of M -30 grade made by
block making machine with strong vibratory compaction, of
11 approved size, design & shape, laid in required colour and 1566.12 Sqm 670.32 1049799.15
pattern over and including 50mm thick compacted bed of
coarse sand, filling the joints with line sand etc. all complete
as per the direction of Engineer-in-charge.
Providing and laying Non Pressure NP-3 class (Medium duty)
R.C.C. pipes including collars/spigot jointed with stiff mixture
of cement mortar in the proportion of 1:2 (1 cement : 2 fine
sand) including testing of joints etc. complete.
200 mm dia RCC pipes. 125.86 RM 646.80 81404.95
Total Amount 3527778.05
Total Amount 3527778.05
Road Page 13 of 87
ENTRANCE GATE SUMMARY SHEET
SL.No DESCRIPTION AMOUNT In Rs.
1 CIVIL WORKS FOR ENTRANCE GATE 4767014.60
2 ELECTRICAL FOR ENTRANCE GATE 614772.79
3 PLUMBING (PHE) FOR ENTRANCE GATE 127173.65
TOTAL FOR ENTRANCE GATE 5508961.04
NAME OF PROJECT: CONSTRUCTION OF CIRCUIT HOUSE AT ROURKELA IN SUNDARGARH DISTRICT OF
ODISHA
BILL OF QUANTITIES
DESCRIPTION OF ITEM QUANTITY UNIT RATE AMOUNT
Earth Work in exavation of foundation in oridinary soil
within initial leads of 50m & lifts of 1.5m including dressing
and levelling of bed etc. and adding contractor's profit and
over head charges, etc. complete in all respect
Extra lift of 1.5m or part there of over the initial lift of 1.5m in
all kinds of embankments and road works and ordinary earth
work in general including labour, T&P & material etc.
complete in all respect.
Filling in F & P with excavated materials including watering
and ramming as directed by the Engineer-n-charge.
Cement Concrete (1:4:8) using 4cm size hard granite C.B.
4 metal approved quality from approved quarry including cost, 9.84 Cum 4011.95 39477.61
carriage, royalty, cost of all labour. etc complete.
R.C.C. work of M-25 grade with 20mm and down grade
black hard granite (crusherbroken) stone chips including
hoisting and laying, labour, material, T&P and lead and
royalty etc. complete in all respect
Foundation 37.56 Cum 5074.61 190602.28
Columns upto plinth 19.43 Cum 5074.61 98599.63
Plinth Beam 2.36 Cum 5074.61 11976.07
Grade Slab 1.42 Cum 5074.61 7205.94
RCC Columns 77.69 Cum 5074.61 394246.30
RCC Beams
Ground Floor 36.24 Cum 5074.61 183903.79
RCC Roof slab beam 0.00 0.00
Ground Floor Roof 8.65 Cum 5074.61 43895.36
Rigid & smooth centering and shuttering for R.C.C.
foundation, plinth band and footing base of column, mass
6 concrete, precast slabs etc. including false works and
dismantling them after casting inclduing cost of material &
labour etc. all complete.
Foundation 34.96 Sqm 111.76 3907.30
Rigid & smooth centering and shuttering for R.C.C. beams,
column, grider and bressmer, etc. including false works and
dismantling them after casting inclduing cost of material &
labour etc. all complete.
Plinth Beam 202.69 Sqm 804.27 163017.89
Ground Floor Roof 932.14 Sqm 804.27 749694.10
Rigid & smooth centering and shuttering for R.C.C. floor and
roof slabs, landings, balconies, projecting, sun shades and
chhajjas including false works and dismantling them after
casting inclduing cost of material & labour etc. all complete.
Upto 4.3 Meter Height
Ground Floor Roof 14.18 Sqm 469.50 6657.57
1st Floor Roof 34.36 Sqm 563.36 19357.05
Rigid & smooth centering and shuttering for R.C.C. walls and
fins inclding attached pillasters etc. including false works and
dismantling them after casting inclduing cost of material &
labour etc. all complete.
Ground Floor 16.65 Sqm 690.37 11494.63
Extra for additional height in centering, shuttering where ever
required with adequate bracing, propping etc., including cost
10 of de-shuttering and decentering at all levels, over a height of
3.5 m, for every additional height of 1 metre or part thereof
(Plan area to be measured).
Suspended floors, roofs, landing, beams and balconies (Plan
area to be measured)
Supplying, fitting and placing uncoated HYSD(Fe 500) bar
reinforcement including cutting, bending and binding with
11 binding wire complete as per drawing and technical
specification including T&P,material, labour and lead &
royalty.
Ground Floor 171.31 Qtl. 8991.02 1540252.32
1st Floor 44.78 Qtl. 9017.01 403781.62
2.5 cm. Damp proof course with C.C. (1:2:4) using 12mm.
Size hard broken granite Chips including cost of carriage and
royalty of all materials, labour etc. all complete under
instruction of EIC.
Brick work with Fly ash Bricks 23cm x 11cm x 8cm size
having crushing strength not less than 75Kg/cm2 with
13 dimensional tolerance ±2 percent in cement mortar (1:6) in
superstructure including watering curing, cost of carriage and
royalty of all materials, cost of all labour, etc complete.
Ground Floor 4.84 Cum 4191.49 20286.80
Brick work with Fly ash Bricks 23cm x 11cm x 8cm size
having crushing strength not less than 75Kg/cm2 with
14 dimensional tolerance ±2 percent in cement mortar (1:4) in
superstructure including watering curing, cost of carriage and
royalty of all materials, cost of all labour, etc complete.
Ground Floor Qty. 1.06 Cum 4400.93 4664.98
12mm thick C.P.(1:6) on brick masonary to the smooth
surface including watering, curing, cost, carriage, royalty of all
materials, cost of all labour, etc complete as per the direction
Ground Floor Qty. 26.51 Sqm 148.18 3928.15
16mm thick C.P. (1:6) over brick masonary to the smooth
surface including watering, curing cost, carriage, royalty, and
taxes of all materials, cost of all labour, etc complete as per
the direction of E.I.C.
Ground Floor Qty. 869.50 Sqm 228.82 198955.51
6 mm thick C.P. (1:4) to RCC surfaces / ceiling finished
smooth including closed deep chiping and slury treatment ,
watering, curing cost, carriage & royalty of all materials, cost
of all labour, etc complete as per the direction of E.I.C.
Ground Floor Qty. 48.24 Sqm 166.77 8044.89
Supplying, fitting and fixing tile in floors of approved make
conformaing to IS:13755 laid on 20 mm thick cement mortar
18 (1:4) and filling joints with white cement of approved quality
including cost of all materials, etc. required for the work all
complete as per direction of E.I.C.
18.1 Vitrified Tiles (600x600) mm
Ground Floor Qty. 10.90 Sqm 1391.15 15163.56
18.2 Anti-Skid / Matte Finish Vitrified Tile (300x300) mm
Ground Floor Qty. 3.32 Sqm 1174.22 3898.39
Fixing tiles in skirting and risers of steps on 12mm thick CP
(1:3) jointed with neat cement slurry mixed with pigments to
match the shade of the tiles including cost, carriage, cost of
all labour etc. complete.
19.1 Vitrified Tiles
Ground Floor Qty. 0.71 Sqm 1508.53 1071.05
19.2 Anti-Skid / Matte Finish Tile (600x600) mm
Ground Floor Qty. 13.54 Sqm 1508.53 20425.47
Fixing tiles in dados / wall tile on 12mm thick CP (1:3) jointed
with neat cement slurry mixed with pigments to match the
shade of the tiles including cost, carriage, cost of all labour
etc. complete.
20.1 Anti-Skid / Matte Finish Vitrified Tile (300x600) mm
Ground Floor Qty. 13.54 Sqm 1449.62 19627.80
Priming one coat with any approved primmer including cost of
21 primmer & labour to give an even shade excluding cost of
primer.
Ground Floor Qty. 74.75 Sqm 59.54 4450.56
Painting two coats with approved enamel paints of approved
colour, shade over a coat of primer including sand papering,
22 polishing the surface, cost, conveyances of all materials and
cost of all labour etc, complete as per specification &
direction of Engineer-in-charge.
Ground Floor Qty. 24.39 Sqm 148.96 3633.13
Finishing wall surface with two coat of Cement based wall
putty (water based) of approved make and finished smooth &
even surface to receive painting including cost of scaffolding
etc. with cost of all materials, labour etc. complete.
Ground Floor Qty. 74.75 Sqm 86.46 6463.18
Wall painting two coat with any approved weather coat paint
24 including cost of all materials, labour and T&P require for the
work etc. complete as directed by the E.I.C.
Ground Floor Qty. 814.93 Sqm 82.43 67176.31
Providing and laying water proofing treatment in sunken
portion of WCs, bathroom etc., by applying cement slurry
mixed with water proofing cement compound consisting of
applying : (a) First layer of slurry of cement @ 0.488 kg/sqm
mixed with water proofing cement compound @ 0.253 kg/
sqm. This layer will be allowed to air cure for 4 hours. (b)
Second layer of slurry of cement @ 0.242 kg/sqm mixed with
water proofing cement compound @ 0.126 kg/sqm. This
layer will be allowed to air cure for 4 hours followed with water
curing for 48 hours. The rate includes preparation of surface,
treatment and sealing of all joints, corners, junctions of pipes
and masonry with polymer mixed slurry.
Providing gola 75 mm x 75 mm in cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 stone aggregate 10 mm and down
26 gauge) including finishing with cement mortar 1:3 (1 cement : 20.30 RM 142.24 2887.47
3 fine sand) all complete as per direction of Engineer-in-
charge.
Making khurras 45x45 cm with average minimum thickness
of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand : 4
graded stone aggregate of 20 mm nominal size) over P.V.C.
27 sheet 1 mx1 mx400 micron, finished with 12 mm cement 2.00 Each 198.24 396.48
plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat
cement,rounding the edges, making and finishing the outlet
complete.
Providing and laying integral cement based water proofing
treatment including preparation of surface as required for
treatment of roofs, balconies, terraces etc consisting of
following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm
of cement admixed with water proofing compound
conforming to IS. 2645 and approved by Engineer-in-charge
over the RCC slab including adjoining walls upto 300 mm
height including cleaning the surface before treatment. (b)
28 Laying brick bats with mortar using broken bricks/brick bats
25 mm to 115 mm size with 50% of cement mortar 1:5 (1
cement : 5 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-
in-charge over 20 mm thick layer of cement mortar of mix 1:5
(1 cement :5 coarse sand ) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-
in-charge to required slope and treating similarly the adjoining
walls upto 300 mm height including rounding of junctions of
walls and slabs.
(c) After two days of proper curing applying a second coat of
cement slurry using 2.75 kg/ sqm of cement admixed with
water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge. (d) Finishing the surface
with 20 mm thick jointless cement mortar of mix 1:4 (1
cement :4 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-
in-charge including laying glass fibre cloth of approved quality
in top layer of plaster and finally finishing the surface with
trowel with neat cement slurry and making pattern of 300x300
mm square 3 mm deep.
(e) The whole terrace so finished shall be flooded with water
for a minimum period of two weeks for curing and for final
test.“All above operations to be done in order and as directed
and specified by the Engineer-in-Charge :
With average thickness of 120 mm and minimum thickness
at khurra as 65mm.
Providing and fixing M.S. grills / MS fabrication work of
required pattern in frames of windows etc. with M.S. flats,
29 square or round bars etc. including priming coat with 902.25 Kg 127.68 115199.85
approved steel primer all complete. Fixed to openings
/wooden frames with rawl plugs screws etc.
Providing and fixing dressed seasoned sal wood work framed
and fixed (wrought and put up) in trusses, purlines, frames of
30 doors, windows, ventilabours and beams including all 0.03 Cum 55824.05 1674.72
complete material, labour and lead & royalty etc. all complete
under instruction of Engineer-in-charge.
Providing and fixing dressed seasoned sal wood work framed
and fixed (wrought and put up) in trusses, purlines, frames of
32 doors, windows, ventilabours and beams including all 3.15 sqm 2939.33 9258.88
complete material, labour and lead & royalty etc. all complete
under instruction of Engineer-in-charge.
Providing and fixing chromium plated brass 100 mm mortice
33 latch and lock with 6 levers and a pair of lever handles of 4.00 each 2733.92 10935.68
approved quality with necessary screws etc. complete.
Providing and fixing chromium plated brass handles with
34 necessary screws etc. complete: 4.00 each 172.48 689.92
Providing and fixing brass tower bolts, ISI marked, required
colour or shade, with necessary screws etc. complete :
250x10 mm each
Providing and fixing bright finished brass hanging type floor
door stopper with necessary screws, etc. complete.
Providing and fixing factory made uPVC white colour sliding
glazed window upto 1.50 m in height dimension comprising of
uPVC multi-chambered frame with in-built roller track and
sash extruded profiles duly reinforced with 1.60 ± 0.2 mm
thick galvanized mild steel section made from roll forming
process of required length (shape & size according to uPVC
profile), appropriate dimension of uPVC extruded glazing
beads and uPVC extruded interlocks, EPDM gasket, wool
pile, zinc alloy (white powder coated) touch locks with hook,
zinc alloy body with single nylon rollers (weight bearing
capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing
frame to finished wall and necessary stainless steel screws
etc. Profile of frame & sash shall be mitred cut and fusion
welded at all corners, including drilling of holes for fixing
hardware's and drainage of water
etc. After fixing frame the gap between frame and adjacent
finished wall shall be filled with weather proof silicon sealent
over backer rod of required size and of approved quality, all
complete as per approved drawing & direction of Engineer-in-
Charge.
Three track three panels sliding window with fly proof S.S
wire mesh (Two nos. glazed & one no. wire mesh panels)
37.1 made of (big series) frame 116 x 45 mm & sash 46 x 62 mm 9.10 Sqm 16503.20 150179.12
both having wall thickness of 2.3 ± 0.2 mm and single glazing
bead / double glazing bead of appropriate dimension
TOTAL AMOUNT 4767014.60
TOTAL AMOUNT 4767014.60
SCHEDULE OF QUANTITIES / BUDGETARY COST ESTIMATE
Rourkela Circuit House, ODISHA
S.No. DESCRIPTION UNIT QTY. RATE AMOUNT
Design, supply, installation, testing & commissioning of Electrical installation:
1.0 SUB HEAD- I :- CIRCUIT CUM POINT WIRING WITH PVC/MS CONDUITING
Item Description for point wiring
1 All wiring shall be of 1100 volts grade.
All wiring shall be HR FRLS PVC insulated unsheathed, flexible, copper conductor, single or multi core as called
Earth wiring shall also be HR FRLS PVC insulated unsheathed, flexible, copper conductor, single core as called
4 Size of earth wire shall be the same as of the phase conductor or as specified otherwise.
All Switches & Sockets shall be of modular design complete with modular plate and suitable sized GI/ moulded
5 boxes as called for and shall be suitable upto 250V, AC supply.
The recessed Switches and Socket outlet boxes shall be of 16G GI and of the same make / manufacturer as of the
6 switches and sockets. Local make boxes are not to be used.
The surface mounted Switches & Sockets outlet boxes shall be moulded and of the same make / manufacturer as
7 of the Switches & Sockets.
8 Flexible conduits, where ever required, shall be of heavy duty and complete with couplers.
10 Conduiting may be concealed or surface mounted (Exposed) as the case may be.
11 Wiring terminations shall be made using proper sized thimbles/ lugs.
All circuit & point wiring shall be colour coded & shall have ferruling on either end for circuit identification.
The rates shall include material & labour for necessary length of circuit and point wiring, earth wiring, rigid and
flexible conduiting, bends, junction boxes, pull boxes, screws, washers, check nuts, couplers, saddles, hangers
supports, GI pull wire, civil work comprising chipping, cutting chases, fixing conduits & making good or surface
clamping of conduit work as the case may be, modular switches, socket outlets, Electronic fan regulators surface or
recessed outlet boxes as the case may be, ceiling rose, rigid and flexible conduit (GI/ MS) as may be required,
connectors and terminal blocks of proper rating etc. & sleeves etc. including lugs/ thimbles for terminations. Fan
points wiring shall include switch as well as electronic speed regulator, and fan hook box with fan hook.Wiring shall
include conduiting and wiring (Phase, Neutral, Earth) of light points/ fan points/ UPS and raw sockets outlets of
required length from the distribution board via switch to the point
Cost of circuit cum point wiring shall include everything and all items and accesOSRies to make the job complete in
14 all respects.
15 For Light Points, Ceiling Fan Points, Exhaust Fan Points, chandelier point & 6A Socket Outlet Points:
i) For switch Controlled light points.
ii) For switch Controlled Exhaust Fan points.
iii) For 6A switched socket outlets.
iv) For MCB Controlled Light points.
v) Wiring with 2x1.5 sqmm + 1x1.5 sqmm (earth wire).
vi) Wiring of required length from DB to point via switch for switch controlled points.
vii) Modular switch & plate for light points
viii) Modular switch and plate for Exhaust Fan point and modular switched socket near Exhaust Fan
ix) Modular 6A, 5 pin switched socket outlets
x) Suitable sizes of GI outlet boxes.
xi) MS/PVC conduiting of required length complete with bends, junction boxes and pull boxes.
xii) Surface or recessed conduiting including civil work like chase cutting and making good as required .
Item Described as above
Recessed wiring to Light Point / Fan Point / Exhaust Fan Point /
Call Bell Point with 1.50 sq. mm FR PVC insulated Single Core
Multi standard Copper Conductor of ISI marked with 20 mm dia
non-metallic PVC flexible conduit with 5 Amp, 250 Volt piano
type swich ISI marked and ceiling rose ISI marked mounted on
MS box having front bakelite cover of suitable size, MS box with
1.0 sq. mm FR PVC insulated Single Core Multi standard
Copper Conductor of ISI marked as earth wire including all
acceOSRies and connection as per direction of engineer in
charge.
a)Light Point
Midium Point 9 679.95 6119.53
b) Celling fan point
Midium(1200MM) Point 1 923.04 923.04
Supply and wiring of MCB controlled light point with FRLS PVC
insulated copper conductor cable in PVC conduit with surface /
recessed with all accesOSRies .
Primary (first) light point with 2X2.5sq.mm+1X2.5 sq.mm FRLS
i) PVC insulated copper conductor cable controlled by a 6A MCB Nos 2 1680.00 3360.00
(MCB cost not to be included here).
Secondary (loop) light point with 2X1.5sq.mm+1X1.5 sq.mm
ii) FRLS PVC insulated copper conductor cable looped to first point Nos 7 840.00 5880.00
and so on.
Recessed wiring for 5 / 6 Amp socket outlet with 2 X 1.50
sq. mm FR PVC insulated Single Core Multi standard Copper
Conductor of ISI marked with 20 mm dia non-metallic PVC
flexible conduit with 5 Amp, 250 Volt piano type swich ISI
marked, Phenolic laminated sheet of suitable size ISI marked
MS box and earthing point with 1 X 1.50 sq. mm FR PVC
insulated Single Core Multi standard Copper Conductor for loop
earthing etc. as required, as per direction of engineer in charge
Short Nos 4 403.75 1615.00
Recessed wiring for 15 / 16 Amp socket outlet with 2 X 4.00
sq. mm FR PVC insulated Single Core Multi standard Copper
Conductor of ISI marked with 20 mm dia non-metallic PVC
flexible conduit with 5 Amp, 250 Volt piano type swich ISI
1.4 marked, Phenolic laminated sheet of suitable size ISI marked
MS box and earthing point with 1 X 2.50 sq. mm FR PVC
insulated Single Core Multi standard Copper Conductor for loop
earthing etc. as required, as per direction of engineer in charge.
Long Nos 1 555.58 555.58
Recessed wiring to Sub-Main in 2 X 2.50 sq. mm FR PVC
insulated Single Core Multi standard Copper Conductor of ISI
marked with 20 mm dia non-metallic PVC heavy duty flexible
conduit with 1.60 mm thick, along with 1 X 1.50 sq. mm FR PVC
insulated Single Core Multi standard Copper Conductor as earth
wire as required as per direction of Engineer-in-Charge.
Total Carried to Summary 19918.51
SUB-HEAD II :- CONDUITING FOR TELEPHONE, INTERCOM
CONDUITING FOR TELEPHONE, INTERCOM & DATA
Supplying and fixing of following sizes of medium class PVC
conduit along with accesOSRies in surface/recess including
cutting the wall and making good the same in case of recessed
conduit as required.
TELEPHONE/ INTERCOM WIRING
Supplying and drawing following pair 0.5 mm dia FRLS PVC
insulated annealed copper conductor, unarmored telephone
2.2 cable in the existing surface/ recessed steel/ PVC conduit as
required.
TELEPHONE TAG BLOCK
Supply, installation, testing & commissioning of telephone tag
blocks with 'KRONE" terminal connectors fixed in 16G powder
2.3 coated, hinged, lockable door, sheet steel enclosure including
civil work such as chase cutting, fixing/ concealing the box and
making good as required including terminations:
i. 10 pair tele tag block No. 1 2240.00 2240.00
TELEPHONE / INTERCOM OUTLET - MODULAR TYPE
Supplying and fixing telephone socket outlet piano type ISI
2.4 marked on the existing switch board / cover including
connections etc as requird.
Telephone socket outlet Nos. 1
OUTLET BOXES FOR TELEPHONE / INTERCOM OUTLET
Supplying and fixing following size/ modules, GI box alongwith
2.5 modular base & cover plate for modular switches in recess etc.
as required.
i. 1 or 2 Module each 1 196.00 196.00
DATA POINT
Supply, Installation testing and commissioning RJ - 45 Computer
2.6 Jack cat 6 with shutter Modular (1Module) each 1 495.04 495.04
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the
2.7 existing surface/ recessed Steel/ PVC conduit as required
i. 1 run of cable meter 10 34.72 347.20
CCTV SYSTEM
Supply, installation, testing and commissioning of UL Listed, 1.3
megapixel (1280 x 960) high resolution IR Bullet Camera, 1/3”
Progressive scan CMOS, [email protected], AGC ON. 0 Lux with IR
on, H.264 / MPEG4 / MJPEG, Dual stream, Bit rate 32 Kbps-
2.8 16Mbps, Standard IP66, 12 VDC ± 10%, PoE (802.3af), 4/6mm Nos. 2 7414.40 14828.80
lens or equivalent high definition,IR range 20-30 mtr, motion
detection, with ONVIF,SIP supported, connectors complete as
required IR Bullet type for mounting recessed in false ceiling or
mounted on wall complete as per tender specifications required.
Supplying and fixing of following sizes of steel conduit along with
accesOSRies in surface/recess including painting in case of
2.14 surface conduit, or cutting the wall and making good the same in
case of recessed conduit as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the
existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable RM 110 34.72 3819.20
Total Carried to Summary 34083.92
SUB-HEAD IV :- CIRCUIT/ SUBMAIN WIRING/CABLES/SUB
MAIN CABLES
Recessed wiring to Sub-Main in 2 X 2.50 sq. mm FR PVC
insulated Single Core Multi standard Copper Conductor of ISI
marked with 20 mm dia non-metallic PVC heavy duty flexible
4.1 conduit with 1.60 mm thick, along with 1 X 1.50 sq. mm FR PVC
insulated Single Core Multi standard Copper Conductor as earth
wire as required as per direction of Engineer-in-Charge.
2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire RM 71 97.69 6936.02
Supplying and fixing of following sizes of medium class PVC
conduit along with accesOSRies in surface/recess including
cutting the wall and making good the same in case of recessed
conduit as required.
Supply , Install , Test , Commission 1100 V FRLS armoured
4.6 cables in trenches , cable trays , ducts , over bed of sand ,
clamped to wall with suitable clamps.
FRLS with only outer sheath
Power Cables 4x10 Sq MM Copper RMT 150 88.03 13204.80
Cable termination of the following PVC armoured cable including
supplying & fixing of crimping lugs , glands . Siemens type gland
upto 70 Sqmm & above flange type glands , double compression
glands for breaded cable. All glands should be earthed. Flying e
Power Cables 4x10 Sq MM Copper SET 2 131.07 262.13
Supply & Install Raceway as per approved makes complete with
the supports , cover plates to be consider as per requirements
.Care shall be taken while cutting the raceways so as to avoid
the burr .
150 MM x 38 MM Out to out Rmt 15 688.80 10332.00
Supply of powder coated junction boxes complete with 20/25
mm Dia holes 8 Nos either side as along with accesOSRies.
Internal Finnish's should be free of burr since the junctions are
being used for carrying data / power cables. , Cover plate should
be powder coated as per the approved color shed. Counter sunk
mirror screw should be provided. Plate should be at least 4 mm
thick. Sample to be approved by client , consultant , client.
150 MM x150 MM x 65 MM Out to out Nos 15 482.72 7240.80
Total Carried to Summary 46136.52
5 SUB HEAD V :- LIGHT FIXTURE & FAN
Supply and fixing of LED Tube Light with batten suitable for up
5.2 to 1 X 20 watt LED tube light complete including tube etc on Nos. 1 1046.64 1046.64
surface complete in all respect.
Supply and Fixing of 10W LED Bulb & fixture with all
5.3 interconnections of approved makes and fixing arrangements as Nos. 2 280.00 560.00
required
Supply, Erection and testing of exhaust fan on the existing hole
5.7 with suitable size of rag bolts, nuts and washers etc., complete Nos. 1 1512.00 1512.00
in all respect.
Supply, Installation, Testing & Commissioning of 1200mm
5.8 Ceiling Fan Nos. 1 7515.20 7515.20
Supply and Fixing of 25W Suspended led & fixture with all
5.1 interconnections of brackets approved makes and fixing Nos. 8 7000.00 56000.00
arrangements as required
Total carried to summary 66633.84
8 EXTERNAL
12 Supply installation, testing & commissioning of Access
Controlled Boom Barrier (6 M) for Ground floor Entry and Exit for
Vehicle with Long Range Reader mounted on the padestal.
Total carried to summary 448,000
Grand Total 614,773
Grand Total 614,773
BILL OF QUANTITIES
DESCRIPTION UNIT QTY RATE AMOUNT
1 SANITARY FIXTURES
Providing and fixing white vitreous china pedestal type
water closet (European type) with seat and lid, 10 litre
low level white vitreous china flushing cistern & C.P.
flush bend with fittings & C.I. brackets, 40 mm flush
bend, overflow arrangement with specials of standard
make and mosquito proof coupling of approved
municipal design complete, including painting of fittings
and brackets, cutting and making good the walls and
floors wherever required :
W.C. pan with ISI marked white solid plastic seat and
1.3 Providing and fixing 8 mm dia C.P. / S.S. Jet with
flexible tube upto1 metre long with S.S. triangular plate
to Eureopean type W.C. of quality and make as
approved by Engineer - in - charge.
1.4 Providing and fixing wash basin with C.I. brackets, 15
mm C.P. brass pillar taps, 32 mm C.P. brass waste of
standard pattern, including painting of fittings and
brackets, cutting and making good the walls wherever
require:
White Vitreous China Wash basin size 550x400 mm
with a pair of 15 mm C.P. brass pillar taps
1.7 Providing and fixing brass bib cock of approved quality
15 MM Nominal Bore Each 2 291.20 582.40
1.8 Providing and fixing C.P. brass angle valve for basin
mixer and geyser points of approved quality
conforming to IS:8931
15 MM Nominal Bore Each 3 511.84 1535.52
1.9 Providing and fixing PTMT grating of approved quality
and colour.
125 mm nominal dia with 25 mm waste hole Each 1 49.28 49.28
Providing and Fixing standard size Chromium Plated
brass or glazed porcelain Toilet paper holder fixed to
woden plugs with Chromium Plated brass screws
complete as per specification.
CP Toilet paper holder Each 1 256.59 256.59
DESCRIPTION UNIT QTY RATE AMOUNT
Providing and Fixing standard sized Chromium Plated
1.18 brass towel ring fixed to wooden plugs with Chromium
Plated brass screws, complete as per specification.
Chromium Plated brass towel ring Each 1 554.18 554.18
Providing and Fixing (a) Liquid Soap Container – Glass
container or Plastic container with Chromium Plated
brass lid and brackets fixed to wooden plugs with
Chromium Plated brass screws or (b) Chromium
1.19 Plated brass soap dish complete with Chromium Each 1 295.01 295.01
Plated brass brackets fixed to wooden plugs with
Chromium Plated brass screws or (c) white glazed
tooth brush holder fixed to wooden plugs with
Chromium Plated brass screws as per specification.
CP soap holder Each 1 100.80 100.80
CP tooth brush holder Each 1 100.80 100.80
Providing & Fixing 600mm x 450mm bevelled edge
mirror of superior glass mounted on 6mm thick A.C
1.20 sheet or plywood sheet and fixed to wooden plugs with
chromium plated brass screws and washers complete
as per specification
600mm x 450mm bevelled edge mirror Each 1 683.31 683.31
Providing & Fixing standard sized glass-shelf with
Chromium Plated brass brackets and guard rails
complete, fixed to woden plugs with Chromium Plated
brass screws as per specification.
600x120 mm glass shelf with anodised aluminium
angle frame, C.P. brass Each 1 316.40 316.40
brackets and guard rail of standard size
TOTAL "SANITARY FIXTURES "CARRIED TO
SUMMARY
SOIL, WASTE, VENT AND RAIN WATER PIPES &
FITTINGS
Providing and fixing on wall face unplasticised Rigid
PVC soil, waste and rain water pipes conforming to
IS : 13592 Type A, including jointing with seal ring
conforming to IS: 5382, leaving 10 mm gap for thermal
expansion, (i) Single socketed pipes
110mm diameter Metre 10 206.86 2068.64
2.3 Providing and fixing to wall or ceiling and floor rigid
UPVC pipes class IV (8 kgf/cm²)/class III (6kgf/cm²)
conforming to IS:4985/2000 and pipe fittings of the
following nominal bore with clamps including making
good the wall, ceiling and floor all complete as per
specification
40 mm diameter Metre 5 99.23 496.16
DESCRIPTION UNIT QTY RATE AMOUNT
2.4 Fixing 100mm size ‘P’ or ‘S’ trap (with horn or without
horn) for water closet squatting pan including jointing
the trap with pan in cement mortar (1:1) as per
specification.
100mm dia SCI 'P' trap Each 1 375.20 375.20
DESCRIPTION UNIT QTY RATE AMOUNT
TOTAL"SOIL, WASTE, VENT AND RAIN WATER
PIPES & FITTINGS "CARRIED TO SUMMARY
3 WATER SUPPLY SYSTEM (Internal & External)
3.1 Providing and fixing to wall or ceiling and floor
galvanized mild steel tubes (medium grade)
conforming to IS: 1239/2004, Part-1 of the following
nominal bore, tube fittings and clamps including
making good the wall, ceiling and floor, testing all
complete as per specification
20mm diameter Metre 5 152.54 762.72
25mm diameter Metre 80 216.50 17319.68
3.2 Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes conforming to IS:15778,having thermal
stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings including fixing the pipe
with clamps at 1.00 m spacing. This includes jointing of
pipes & fittings with one step CPVC solvent cement
and testing of joints complete as per direction of
Engineer-in-Charge
15mm diameter Metre 10 124.66 1246.56
20mm diameter Metre 2 148.29 296.58
25mm diameter Metre 2 193.54 387.07
Fixing of Brass Ball Valve (Horizontal plunger type)
conforming to IS 1703-1977 as per specification
complete
High pressure/Low pressure with copper or PVC floats
of the following nominal bore
25mm diameter Each 1 537.60 537.60
3.5 Providing and fixing ball valve (brass) of approved
quality, High or low pressure, with plastic floats
complete
20 mm dia nominal bore Each 1 371.84 371.84
TOTAL"WATER SUPPLY SYSTEM (Internal &
External) "CARRIED TO SUMMARY
DESCRIPTION UNIT QTY RATE AMOUNT
5 SEWERAGE & DRAINAGE SYSTEM
Excavation of trenches of required width for pipes,
including dressing of sides, ramming of bottom, depth
upto 1.5m including getting out the excavated soil, and
then returning the soil as required, in layers not
exceeding 20cms depth including consolidating
each deposited layers by ramming, watering, etc. and
disposing of surplus excavated soil as directed
outside the site to the approved dumping ground.
In all kind of soils
Pipes exceeding 100mm dia but not exceeding 300mm
Metre 80 268.80 21504.00
Laying (to level or slopes) and jointing with rubber
rings pre-cast reinforced socket and spigot concrete
pipes Class NP-2 conforming to IS:458 - 2003 suitable
for rubber ring roll on joint of the following internal
diameter as per specification complete.(Earthwork in
trenches to be measured and paid for separately)
150mm diameter Metre 80 493.81 39504.64
5.3 Providing and fixing square-mouth S.W. gully trap
class SP-1 complete with C.I.grating brick masonry
chamber with water tight C.I. cover with frame of
300x300 mm size (inside) the weight of cover to be not
less than 4.50 kg and frame to be not less than 2.70 kg
as per standard design
180x150 mm size P type Each 1 1476.05 1476.05
Constructing manholes with R.C.C top slab in (1:2:4)
mix, foundation concrete (1:4:8), inside plaster 12mm
thick with cement mortar (1:3) finished with neat
cement punning, 12mm thick outside cement plaster
(1:3), brick work with K.B bricks having crushing
strength not less than
75kg/cm² with dimensional tolerance ± 8 percent in
cement mortar (1:5), cement concrete (1:2:4) finished
smooth using 12mm size h.g chips, earthwork in
excavation in all kinds of soil and refilling the cavity
around the chamber complete as per specification.
Plain Manholes inside size 900mm x 800mm and
450mm deep - Type A
TOTAL "SEWERAGE & DRAINAGE SYSTEM
"CARRIED TO SUMMARY
TOTAL FOR ENGRANCE GATE 127173.65
Construction of Septic Tank & Soak Pit in Circuit house, Rourkela in Odisha
Bill of Quantity
Description Unit Qty. Rate Amount
Earth Work in exavation of foundation in oridinary soil within initial
leads of 50m & lifts of 1.5m including dressing and levelling of bed
etc. and adding contractor's profit and over head charges, etc.
complete in all respect
Extra lift of 1.5m or part there of over the initial lift of 1.5m in all
kinds of embankments and road works and ordinary earth work in
general including labour, T&P & material etc. complete in all
respect.
Filling in F & P with excavated materials including watering and
ramming as directed by the Engineer-n-charge.
Cement Concrete (1:4:8) using 4cm size hard granite C.B. metal
4 approved quality from approved quarry including cost, carriage, Cum 1.34 4011.95 5385.28
royalty, cost of all labour. etc complete.
Rigid & smooth centering and shuttering for R.C.C. foundation,
plinth band and footing base of column, mass concrete, precast
slabs etc. including false works and dismantling them after casting
inclduing cost of material & labour etc. all complete.
Foundation Sqm 5.18 111.76 578.49
Rigid & smooth centering and shuttering for R.C.C. walls and fins
inclding attached pillasters etc. including false works and
dismantling them after casting inclduing cost of material & labour
etc. all complete.
Ground Floor Sqm 50.08 690.37 34572.94
Rigid & smooth centering and shuttering for R.C.C. floor and roof
slabs, landings, balconies, projecting, sun shades and chhajjas
including false works and dismantling them after casting inclduing
cost of material & labour etc. all complete.
Ground Floor Roof Sqm 8.28 469.50 3889.82
R.C.C. work of M-25 grade with 20mm and down grade black hard
granite (crusherbroken) stone chips including hoisting and laying.
All work upto Ground Floor Cum 4.21 5074.61 21377.31
Supplying, fitting and placing uncoated HYSD(Fe 500) bar
reinforcement including cutting, bending and binding with binding
wire complete as per drawing and technical specification including
T&P,material, labour and lead & royalty.
Upto Ground floor Qtl 3.37 8991.02 30300.50
Brick work with Fly ash Bricks 23cm x 11cm x 8cm size having
crushing strength not less than 75Kg/cm2 with dimensional
10 tolerance ±2 percent in cement mortar (1:6) in superstructure
including watering curing, cost of carriage and royalty of all
materials, cost of all labour, etc complete.
Ground Floor Cum 8.84 4191.49 37061.56
Cement Concrete (1:2:4) using 12mm size hard granite C.B. chips
11 approved quality from approved quarry including cost, carriage, Cum 1.12 5997.86 6718.26
royalty, cost of all labour. etc complete and as directed by E.I.C.
Dry brick on edge flooring in required pattern with bricks of class
12 designation 7.5 on a bed of 12 mm mud mortar, including filling Sqm 1.56 463.12 724.20
joints with sand, with common burnt clay non modular bricks.
Providing orange colour safety foot rest of minimum 6 mm thick
plastic encapsulated as per IS : 10910, on 12 mm dia steel bar
conforming to IS: 1786, having minimum cross section as 23
mmx25 mm and over all minimum length 263 mm and width as 165
mm with minimum 112 mm space between protruded legs having 2
mm tread on top surface by ribbing or chequering besides
13 necessary and adequate anchoring projections on tail length on 138 Each 22.00 383.71 8441.66
mm as per standard drawing and suitable to with stand the bend
test and chemical resistance test as per specifications and having
manufacture's permanent identification mark to be visible even after
fixing, including fixing in manholes with 30x20x15 cm cement
concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) complete as per design.
14 Supplying and fixing C.I. cover without frame for manholes :
560 mm diameter C.I. cover (heavy duty) the weight of the cover to
be not less than 108 kg
Supply and filling of brick ballast for soak pit of approved size as
15 shown in the drawing etc. all complete under instruction of Engineer
in charge.
15.1 40mm thick Brick Ballast Aggregate Cum 2.51 4090.24 10285.12
15.2 50 to 80mm Brick Ballast Aggregate Cum 0.78 4090.24 3202.81
Honey-comb brick work 10 / 11.4 cm thick with common burnt clay
16.0 bricks of class designation 7.5 in substructure upto plinth level with Sqm 3.09 329.62 1020.12
cement mortar 1:4 (1 cement : 4 coarse sand).
Supply and filling of brick bats for soak pit of approved size as
17 shown in the drawing etc. all complete under instruction of Engineer Cum 0.27 1131.20 308.77
in charge.
Total Amount 184,162.90
Total Amount 184,162.90
EXISTING BUILDING (RENOVATION & REPAIRING WORK) SUMMARY SHEET
SL.No DESCRIPTION AMOUNT In Rs.
1 CIVIL WORKS FOR EXISITNG BUILDING 643657.38
2 ELECTRICAL FOR EXISITNG BUILDING 202510.96
3 PLUMBING (PHE) FOR EXISITNG BUILDING 159621.28
TOTAL FOR EXISITNG BUILDING 1005789.61
NAME OF PROJECT: CONSTRUCTION OF CIRCUIT HOUSE AT ROURKELA IN SUNDARGARH DISTRICT OF
ODISHA
BILL OF QUANTITIES (REPAIRING WORKS)
DESCRIPTION OF ITEM QUANTITY UNIT RATE AMOUNT
Dismantling brick masonry in cement mortar 3m. Height including
1 stacking the useful materials for reuse and removing the debris 4.00 Cum 1203.43 4813.72
within 50m. Lead as suggested by EIC.
Dismantling and removing 2.5 cm. thick artificial stone flooring
2 including stacking the useful materials for reuse and removing 55.09 Sqm 86.17 4746.85
the debris within 50m lead.
Dismantling and removing doors, windows and ventilators
including removal of frame, hinges, fastening and stacking the
3 same for reuse and removing the debris within 50m lead as 4.20 Sqm 899.95 3779.81
suggested by EIC.
Removing old lime or cement plaster from walls including raking
4 out joints 12 mm deep and removing the debris within 50m lead as 274.46 Sqm 43.09 11825.41
suggested by EIC.
Brick work with Fly ash Bricks 23cm x 11cm x 8cm size having
crushing strength not less than 75Kg/cm2 with dimensional
5 tolerance ±2 percent in cement mortar (1:6) in Foundation and
Plinth including watering curing, cost of carriage and royalty of all
materials, cost of all labour, etc complete.
GROUND FLOOR 1.65 Cum 4191.49 6915.96
12mm thick C.P.(1:6) on brick masonary to the smooth surface
6 including watering, curing, cost, carriage, royalty of all materials,
cost of all labour, etc complete as per the direction of E.I.C.
GROUND FLOOR 54.18 Sqm 148.18 8028.18
16mm thick C.P. (1:6) over brick masonary to the smooth surface
including watering, curing cost, carriage, royalty, and taxes of all
materials, cost of all labour, etc complete as per the direction of
Ground Floor 183.12 Sqm 228.82 41901.47
1st Floor 66.98 Sqm 238.34 15963.98
6 mm thick C.P. (1:4) to RCC surfaces finished smooth including
closed deep chiping and slury treatment , watering, curing cost,
carriage & royalty of all materials, cost of all labour, etc complete
as per the direction of E.I.C.
Ground Floor 78.72 Sqm 166.77 13127.98
Painting two coats with approved paint on old wood work including
sand papering, polishing the surface, cost, conveyances of all
materials and cost of all labour etc, complete as per specification
& direction of Engineer-in-charge.
Ground Floor Qty. 147.28 Sqm 148.96 21938.83
Painting two coats with approved paint on old iron work with
approved enamel paints of approved colour, shade over a coat of
10 primer including sand papering, polishing the surface, cost,
conveyances of all materials and cost of all labour etc, complete
as per specification & direction of Engineer-in-charge.
Ground Floor Qty. 147.28 Sqm 148.96 21938.83
Finishing wall surface with two coat of Cement based wall putty
(water based) of approved make and finished smooth & even
surface to receive painting including cost of scaffolding etc. with
cost of all materials, labour etc. complete.
Ground Floor Qty. 132.90 Sqm 101.02 13426.09
Priming 1 coat with wall primer water bond cement primer
including all labour, materials etc. complete.
Ground Floor 1058.83 Sqm 60.48 64038.04
Wall painting 2 coats with plastic emulsion paint of approved
shade on new work to give an even shade exculding cost of paint
Ground Floor 131.44 Sqm 115.02 15118.75
Wall painting 1 coat with plastic emulsion paint of approved shade
on old work to give an even shade exculding cost of paint.
Ground Floor Qty. 1058.83 Sqm 94.08 99614.73
Wall painting two coat with any approved weather coat paint
15 including cost of all materials, labour and T&P require for the work
etc. complete as directed by the E.I.C.
Ground Floor Qty. 183.12 Sqm 82.43 15095.20
1st Floor 66.98 Sqm 84.45 5656.41
Providing and fixing dressed seasoned sal wood work framed and
fixed (wrought and put up) in trusses, purlines, frames of doors,
16 windows, ventilabours and beams including all complete material, 0.05 Cum 55824.05 2791.20
labour and lead & royalty etc. all complete under instruction of
Engineer-in-charge.
Providing and fixing 32mm piasal wood or local Teak wood
panelled shutters moulded panels with all labour, iron fittings, and
wooden hinged cleats etc fitted and fixed complete in all respect.
But excluding the cost of iron fittings
Providing and fixing chromium plated brass 100 mm mortice latch
18 and lock with 6 levers and a pair of lever handles of approved 2.00 each 2733.92 5467.84
quality with necessary screws etc. complete.
Providing and fixing chromium plated brass handles with
19 necessary screws etc. complete: 2.00 each 172.48 344.96
Providing and fixing brass tower bolts, ISI marked, required colour
or shade, with necessary screws etc. complete : 250x10 mm each
Providing and fixing bright finished brass hanging type floor door
stopper with necessary screws, etc. complete.
Providing and fixing aluminium die cast body tubular type universal
hydraulic door closer (having brand logo with ISI, IS : 3564,
22 embossed on the body, door weight upto 35 kg and door width 2.00 each 2047.36 4094.72
upto 700 mm), with necessary accessories and screws etc.
complete. each
5 cm thick grading concrete (1:2:4) on roof slab with 12mm &
down grade size black hard granite chips for old & New work.
2nd Floor 42.80 Sqm 1733.32 74186.19
Providing and fixing factory made uPVC door frame made of
uPVC extruded sections having an overall dimension as below
(tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners
of the door frame to be Jointed with galvanized brackets and
24 stainless steel screws, joints mitred and Plastic welded. The hinge
side vertical of the frames reinforced by galvanized M.S. tube of
size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos.
stainless steel hinges fixed to the frame complete as per
manufacturer’s specification and direction of Engineer- in-charge
Extruded section profile size 42x50 mm 47.70 Rmt. 242.03 11544.93
25 Providing and fixing to existing door frames.
30 mm thick factory made Polyvinyl Chloride (PVC) door shutter
made of styles and rails of a uPVC hollow section of size 60x30
mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative
moulding edging on one side. The styles and rails mitred and joint
at the corners by means of M.S. galvanised/ plastic brackets of
size 75x220 mm having wall thickness 1.0 mm and stainless steel
screws. The styles of the shutter reinforced by inserting galvanised
M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness.
25.1 The lock rail made up of 'H' section, a uPVC hollow section of size 18.90 Sqm 1828.06 34550.41
100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the
shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The
shutter frame filled with a uPVC multichambered single panel of
size not less than 620 mm, having over all thickness of 20 mm and
1 mm (± 0.1 mm) wall thickness . The panels filled vertically and
tie bar at two places by inserting horizontally 6 mm galvanised
M.S. rod and fastened with nuts and washers, complete as per
manufacturer's specification and direction of Engineer-in-charge.
Providing and fixing aluminium sliding door bolts, ISI marked
anodised (anodic coating not less than grade AC 10 as per IS :
1868), transparent or dyed to required colour or shade, with nuts
and screws etc. complete :
26.1 250x16 mm 9.00 each 203.84 1834.56
Providing and fixing aluminium tower bolts, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868 )
transparent or dyed to required colour or shade, with necessary
screws etc. complete :
27.1 250x10 mm 9.00 each 92.40 831.60
Supplying, fitting and fixing tile in floors of approved make
conformaing to IS:13755 laid on 20 mm thick cement mortar (1:4)
28 and filling joints with white cement of approved quality including
cost of all materials, etc. required for the work all complete as per
direction of E.I.C.
28.1 Anti-Skid / Matte Finish Vitrified Tile (300x300) mm
Ground Floor Qty. 78.71 Sqm 1174.22 92422.46
29.2 Granite tiles (20mm thk.)
Ground Floor Qty. 8.17 Sqm 2784.39 22748.47
Fixing tiles in dados / wall tile on 12mm thick CP (1:3) jointed with
29 neat cement slurry mixed with pigments to match the shade of the
tiles including cost, carriage, cost of all labour etc. complete.
29.1 Anti-Skid / Matte Finish Vitrified Tile (300x600) mm
Ground Floor Qty. 8.17 Sqm 1449.62 11843.36
TOTAL AMOUNT 643657.38
TOTAL AMOUNT 643657.38
SCHEDULE OF QUANTITIES / BUDGETARY COST ESTIMATE
Rourkela Circuit House, ODISHA
S.No. DESCRIPTION UNIT RATE AMOUNT
Design, supply, installation, testing & commissioning of Electrical installation:
1.0 SUB HEAD- I :- CIRCUIT CUM POINT WIRING WITH PVC/MS CONDUITING
Item Description for point wiring
1 All wiring shall be of 1100 volts grade.
All wiring shall be HR FRLS PVC insulated unsheathed, flexible, copper conductor, single or multi core as called
Earth wiring shall also be HR FRLS PVC insulated unsheathed, flexible, copper conductor, single core as called
4 Size of earth wire shall be the same as of the phase conductor or as specified otherwise.
All Switches & Sockets shall be of modular design complete with modular plate and suitable sized GI/ moulded
boxes as called for and shall be suitable upto 250V, AC supply.
The recessed Switches and Socket outlet boxes shall be of 16G GI and of the same make / manufacturer as of the
switches and sockets. Local make boxes are not to be used.
The surface mounted Switches & Sockets outlet boxes shall be moulded and of the same make / manufacturer as
7 of the Switches & Sockets.
8 Flexible conduits, where ever required, shall be of heavy duty and complete with couplers.
10 Conduiting may be concealed or surface mounted (Exposed) as the case may be.
11 Wiring terminations shall be made using proper sized thimbles/ lugs.
12 All circuit & point wiring shall be colour coded & shall have ferruling on either end for circuit identification.
The rates shall include material & labour for necessary length of circuit and point wiring, earth wiring, rigid and
flexible conduiting, bends, junction boxes, pull boxes, screws, washers, check nuts, couplers, saddles, hangers
supports, GI pull wire, civil work comprising chipping, cutting chases, fixing conduits & making good or surface
clamping of conduit work as the case may be, modular switches, socket outlets, Electronic fan regulators surface
or recessed outlet boxes as the case may be, ceiling rose, rigid and flexible conduit (GI/ MS) as may be required,
connectors and terminal blocks of proper rating etc. & sleeves etc. including lugs/ thimbles for terminations.
Fan points wiring shall include switch as well as electronic speed regulator, and fan hook box with fan hook.Wiring
shall include conduiting and wiring (Phase, Neutral, Earth) of light points/ fan points/ UPS and raw sockets outlets
of required length from the distribution board via switch to the point
Cost of circuit cum point wiring shall include everything and all items and accessories to make the job complete in
14 all respects.
15 For Light Points, Ceiling Fan Points, Exhaust Fan Points, chandelier point & 6A Socket Outlet Points:
i) For switch Controlled light points.
ii) For switch Controlled Exhaust Fan points.
iii) For 6A switched socket outlets.
iv) For MCB Controlled Light points.
v) Wiring with 2x1.5 sqmm + 1x1.5 sqmm (earth wire).
vi) Wiring of required length from DB to point via switch for switch controlled points.
vii) Modular switch & plate for light points
viii) Modular switch and plate for Exhaust Fan point and modular switched socket near Exhaust Fan
ix) Modular 6A, 5 pin switched socket outlets
x) Suitable sizes of GI outlet boxes.
xi) MS/PVC conduiting of required length complete with bends, junction boxes and pull boxes.
xii) Surface or recessed conduiting including civil work like chase cutting and making good as required .
Item Described as above
Recessed wiring to Light Point / Fan Point / Exhaust
Fan Point / Call Bell Point with 1.50 sq. mm FR PVC
insulated Single Core Multi standard Copper Conductor
of ISI marked with 20 mm dia non-metallic PVC flexible
conduit with 5 Amp, 250 Volt piano type swich ISI
1.1 marked and ceiling rose ISI marked mounted on MS box
having front bakelite cover of suitable size, MS box with
1.0 sq. mm FR PVC insulated Single Core Multi
standard Copper Conductor of ISI marked as earth wire
including all accesories and connection as per direction
of engineer in charge.
a)Light Point
Midium Point 50 679.95 33997.37
b) Celling fan point
Midium(1200MM) Point 8 923.04 7384.35
Short Nos 12 403.75 4845.01
Recessed wiring for 15 / 16 Amp socket outlet with 2
X 4.00 sq. mm FR PVC insulated Single Core Multi
standard Copper Conductor of ISI marked with 20 mm
dia non-metallic PVC flexible conduit with 5 Amp, 250
Volt piano type swich ISI marked, Phenolic laminated
sheet of suitable size ISI marked MS box and earthing
point with 1 X 2.50 sq. mm FR PVC insulated Single
Core Multi standard Copper Conductor for loop earthing
etc. as required, as per direction of engineer in charge.
Long Nos 6 555.58 3333.48
Recessed wiring for 20 Amp socket outlet with 2 X
4.00 sq. mm FR PVC insulated Single Core Multi
standard Copper Conductor of ISI marked with 20 mm
dia non-metallic PVC flexible conduit with 5 Amp, 250
Volt piano type swich ISI marked, Phenolic laminated
1.5 sheet of suitable size ISI marked MS box and earthing
point with 1 X 2.50 sq. mm FR PVC insulated Single
Core Multi standard Copper Conductor for loop earthing
etc. as required, as per direction of engineer in charge.
Short Nos 8 730.13 5841.02
Recessed wiring for AC 20 Amp socket outlet with 2
X 6.00 sq. mm FR PVC insulated Single Core Multi
standard Copper Conductor of ISI marked with 20 mm
dia non-metallic PVC flexible conduit with 5 Amp, 250
Volt piano type swich ISI marked, Phenolic laminated
sheet of suitable size ISI marked MS box and earthing
point with 1 X 2.50 sq. mm FR PVC insulated Single
Core Multi standard Copper Conductor for loop earthing
etc. as required, as per direction of engineer in charge.
Recessed wiring to Sub-Main in 2 X 2.50 sq. mm FR
PVC insulated Single Core Multi standard Copper
Conductor of ISI marked with 20 mm dia non-metallic
PVC heavy duty flexible conduit with 1.60 mm thick,
1.6 along with 1 X 1.50 sq. mm FR PVC insulated Single Nos 8 97.69 781.52
Core Multi standard Copper Conductor as earth wire as
required as per direction of Engineer-in-Charge.
Total Carried to Summary 65590.75
SUB-HEAD II :- CONDUITING FOR TELEPHONE,
2 INTERCOM & DATA 0.00 0.00
CONDUITING FOR TELEPHONE, INTERCOM & DATA 0.00 0.00
Supplying and fixing of following sizes of medium class
PVC conduit along with accessories in surface/recess
2.1 including cutting the wall and making good the same in
case of recessed conduit as required.
TELEPHONE / INTERCOM OUTLET - MODULAR
Supplying and fixing telephone socket outlet piano type
2.4 ISI marked on the existing switch board / cover including
connections etc as requird.
i. Telephone socket outlet Nos. 8 44.32 354.56
OUTLET BOXES FOR TELEPHONE / INTERCOM
OUTLET
Supplying and fixing following size/ modules, GI box
2.5 alongwith modular base & cover plate for modular
switches in recess etc. as required.
i. 1 or 2 Module each 2 196.00 392.00
DATA POINT
Supply, Installation testing and commissioning RJ - 45
2.6 Computer Jack cat 6 with shutter Modular (1Module) each 2 495.04 990.08
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable
2.7 in the existing surface/ recessed Steel/ PVC conduit as
required
i. 1 run of cable meter 35 34.72 1215.20
Total Carried to Summary 4426.88
SUB-HEAD IV :- CIRCUIT/ SUBMAIN
WIRING/CABLES/SUB MAIN CABLES
Recessed wiring to Sub-Main in 2 X 2.50 sq. mm FR
PVC insulated Single Core Multi standard Copper
Conductor of ISI marked with 20 mm dia non-metallic
PVC heavy duty flexible conduit with 1.60 mm thick,
along with 1 X 1.50 sq. mm FR PVC insulated Single
Core Multi standard Copper Conductor as earth wire as
required as per direction of Engineer-in-Charge.
2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire RM 35 97.69 3419.16
4 X 10.00 sq. mm PVC INSULATED ALUMINUM
CONDUCTOR insulated 4 Core Multi standard AL.
Conductor of ISI marked with 32 mm dia non-metallic
PVC heavy duty conduit with 1.60 mm thick, along with
4.4 1 X 4 sq. mm FR PVC insulated Single Core Multi RM 20 525.60 10512.08
standard copper Conductor as earth wire as required as
per direction of Engineer-in-Charge.
Total Carried to Summary 13931.25
5 SUB HEAD V :- LIGHT FIXTURE & FAN
Supply and fixing of recess/ Surface/ Pendent mounting
round 10 to 12 Watt LED Down Lighter having Powder
5.1 coated diecast aluminium housing with heat sink, Nos 8 282.24 2257.92
diffuser/ Reflector and driver set complete in all respect.
Supply and fixing of LED Tube Light with batten suitable
for up to 1 X 20 watt LED tube light complete including
5.2 tube etc on surface complete in all respect. Nos. 10 1046.64 10466.40
Supply and Fixing of 10W LED Bulb & fixture with all
5.3 interconnections of approved makes and fixing Nos. 8 280.00 2240.00
arrangements as required
Supply and Fixing of 18W led downlighter & fixture with
5.4 all interconnections of approved makes and fixing Nos. 4 1125.04 4500.16
arrangements as required
Supply and Fixing of 10W Mirror Light & fixture with all
5.5 interconnections of approved makes and fixing Nos. 5 448.00 2240.00
arrangements as required
Supply, Erection and testing of exhaust fan on the
5.7 existing hole with suitable size of rag bolts, nuts and Nos. 6 1512.00 9072.00
washers etc., complete in all respect.
Supply, Installation, Testing & Commissioning of
5.8 1200mm Ceiling Fan Nos. 8 7515.20 60121.60
Total carried to summary 90898.08
8 EXTERNAL
Supply and fixing of LED Street light Fitting having die
cast aluminium body and diffuser with driver set suitable
for 45 watt to 50 Watt. Confirming to IP 65 and above
protection complete in all respect. CAT. AAA
Total carried to summary 27,664
Grand Total 202,511
Grand Total 202,511
BILL OF QUANTITIES
AMOUNT
S.No TOTA
DESCRIPTION UNIT RATE AS PER
1 SANITARY FIXTURES
Providing and fixing white vitreous china pedestal type
water closet (European type) with seat and lid, 10
litre low level white vitreous china flushing cistern &
C.P. flush bend with fittings & C.I. brackets, 40 mm
flush bend, overflow arrangement with specials of
standard make and mosquito proof coupling of
approved municipal design complete, including
painting of fittings and brackets, cutting and making
good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and
1.3 Providing and fixing 8 mm dia C.P. / S.S. Jet with
flexible tube upto1 metre long with S.S. triangular
plate to Eureopean type W.C. of quality and make as
approved by Engineer - in - charge.
1.5 Providing and fixing wash basin with C.I. brackets, 15
mm dia CP Brass single hole basin mixer of
approved quality and make, including painting of
fittings and brackets, cutting and making good the Each 4 4239.20 16,957
walls wherever required:- (a) White Vitreous China
Wash basin size 550x400 mm with a 15 mm CP
Brass single hole basin mixer
1.6 Providing and fixing white vitreous china flat back or
wall corner type lipped front urinal basin of
430x260x350 mm and 340x410x265 mm sizes
respectively with automatic flushing cistern with
standard flush pipe and C.P. brass spreaders with
brass unions and G.I clamps complete, including
painting of fittings and brackets, cutting and making
good the walls and floors wherever required :
One urinal basin with 5 litre white P.V.C. automatic
flushing cistern
1.7 Providing and fixing brass bib cock of approved
quality :
15 MM Nominal Bore Each 10 291.20 2,912
1.8 Providing and fixing C.P. brass angle valve for basin
mixer and geyser points of approved quality
conforming to IS:8931
15 MM Nominal Bore Each 28 511.84 14,332
1.9 Providing and fixing PTMT grating of approved quality
and colour.
AMOUNT
S.No TOTA
DESCRIPTION UNIT RATE AS PER
125 mm nominal dia with 25 mm waste hole Each 11 49.28 542
Providing and fixing C.P. brass shower rose with 15
or 20 mm inlet :
100 mm diameter Each 8 146.72 1,174
Providing and fixing CP Brass Single lever
telephonic wall mixer of quality & make as approved
by Engineer in charge.
(a) 15 mm nominal dia Each 8 5885.60 47,085
Providing and Fixing standard size Chromium Plated
brass or glazed porcelain Toilet paper holder fixed to
woden plugs with Chromium Plated brass screws
complete as per specification.
CP Toilet paper holder Each 8 256.59 2,053
Providing and Fixing standard sized Chromium Plated
brass towel rail complete with Chromium Plated
brass brackets fixed to wooden plugs with Chromium
Plated brass screws, complete as per specification.
Chromium Plated brass towel rail Each 8 1037.57 8,301
Providing and Fixing standard sized Chromium Plated
brass towel ring fixed to wooden plugs with
Chromium Plated brass screws, complete as per
specification.
Chromium Plated brass towel ring Each 8 554.18 4,433
Providing and Fixing (a) Liquid Soap Container –
Glass container or Plastic container with Chromium
Plated brass lid and brackets fixed to wooden plugs
with Chromium Plated brass screws or (b) Chromium
1.19 Plated brass soap dish complete with Chromium Each 8 295.01 2,360
Plated brass brackets fixed to wooden plugs with
Chromium Plated brass screws or (c) white glazed
tooth brush holder fixed to wooden plugs with
Chromium Plated brass screws as per specification.
CP soap holder Each 8 100.80 806
CP tooth brush holder Each 8 100.80 806
CP double coat hook Each 8 252.00 2,016
Providing & Fixing 600mm x 450mm bevelled edge
mirror of superior glass mounted on 6mm thick A.C
1.20 sheet or plywood sheet and fixed to wooden plugs
with chromium plated brass screws and washers
complete as per specification
600mm x 450mm bevelled edge mirror Each 8 683.31 5,466
AMOUNT
S.No TOTA
DESCRIPTION UNIT RATE AS PER
Providing & Fixing standard sized glass-shelf with
Chromium Plated brass brackets and guard rails
complete, fixed to woden plugs with Chromium Plated
brass screws as per specification.
600x120 mm glass shelf with anodised aluminium
angle frame, C.P. brass Each 8 316.40 2,531
brackets and guard rail of standard size
Providing and fixing Stainless Steel A ISI 304 (18/8)
kitchen sink as per IS 13983 with C.I brackets and
1.22 stainless steel plug 40 mm, including painting of
fittings and brackets, cutting and making good the
walls wherever required
Stainless steel kitchen sink - with drain board
510x1040 mm bowl depth 250 mm
TOTAL "SANITARY FIXTURES "CARRIED TO
SUMMARY
PROPOSED ESTIMATE OF SIGNAGE FOR CIRCUIT HOUSE IN SUNDARGARH DISTRICT OF ODISHA
DESIGN, DRAWING & SITC OF SIGNAGE
NO. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
(NON SCHEDULE ITEMS)
1 Sign Typology for EXTERNAL SIGNAGE
1.1 TS - Totem Signs at Main entry Gate (18'6" x 4'6") 1 Nos. 360640.00 360640.00
Providing, Fixing & Preparing Graphics and Artworks for Tri-
lingual Single Sided Totem Sign of size 18'-6" x 4'-6" at gates.
The existing structure between the two column shall be
modified as per design i.e. brick wall raised by 4'-6" and shall
be clad in 20mm thk. black granite. All graphics etched and
coulour-filled as per approved artworks, with transportation and
installation at site complete.
1.2 SM - Site Map (3' x 7') 1 Nos. 386400.00 386400.00
Providing, Fixing & Preparing Graphics and Artworks for Single
Sided Bilingual Site Map of size 3' x 7', fabricated as per
approved drawing, using 304 grade SS channels, 3" x 2" x
2mm thk., of size 35" width x 8'-6" height, embedded 18"
verticaly into ground with proper foundation in cement concrete
in 1:2:4, with sign panels in 20mm thick Black Granite, (with
approved artworks and graphics etched and color filled) bolted
over SS framework with necessary hardware and tools
required for proper fixing for the same in position, with
transportation and installation at site complete.
2 Sign Typology for INTERNAL SIGNAGE
2.1 DF - Fixed Door Signs (16" x 8") 90 Nos. 5987.52 538876.80
Providing, Fixing & Preparing Graphics & Artworks for
Trilingual ID-2 Signs of size 14" x 6", in 5mm thk. Clear Acrylic,
laser cut to appropriate size and shape, with all graphics 'flat-
bed' printed directly onto acrylic surface in reverse as per
approved artworks, fixed to existing surface using
studs/spacers/ brackets or 3M double sided tapes whichever
appropriate as per site conditions, using necessary hardware
and tools, with transportation and installation at site complete.
eg. Seminar room, Cafeteria, office Room, VIP room, Rooms
,Lift No., gym, toilets, banquet hall, club, lounge, services &
name, c.
2.2 WF - Wayfinding Signs (48" x 12") 4 Nos. 27167.84 108671.36
Providing, Fixing & Preparing Graphics & Artworks for tri-
lingual Suspended Directional Signs of size 48" x 12", in 5mm
thk. Clear Acrylic, laser cut to appropriate size and shape, with
all graphics 'flat-bed' printed directly onto acrylic surface in
reverse as per approved artworks, fixed to existing surface
using studs/ spacers/ brackets/ suspension mechanisms or 3M
double sided tapes whichever appropriate as per site
conditions, using necessary hardware and tools, with
transportation and installation at site complete.
Mostly in Corridors
TOTAL FOR SIGNAGE 1394588.16
SUMMARY OF COST FOR FIRE MANAGEMENT SYSTEM
S.No. Description AMOUNT
1 FIRE FIGHTING WORKS 874463.03
2 FIRE DETECTION & ALARM SYSTEM 1006989.64
TOTAL FOR FIRE MANAGEMENT SYSTEM 1881452.67
FIRE FIGHTING ESTIMATE
No DESCRIPTION UNIT QTY. RATE AMOUNT
A. FIRE PUMP & EQUIPMENT
1.0 Supplying, installation, testing and commissioning of electric
driven terrace pump suitable for automatic operation and
consisting of following, complete in all respects, as required:
(Terrace Pump)
(a) Horizontal type, multistage, centrifugal, split casing pump of
cast iron body & bronze impeller with stainless steel shaft,
mechanical confirming to IS : 1520
b) Suitable HP squirell cage induction motor TEFC type suitable
for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55
class of protection for enclosure, horiziontal foot mounted type
with Class-'F' insulation, conforming to IS-325.
(c) M.S.fabricated common base plate, coupling, coupling guard,
foundation bolts etc.as required.
(d) Suitable cement concrete foundation duly plastered and with
anti vibration pads.
450 lpm at 35 m Head Set 1 83757 83757
2.0 Air Vessel for Fire Pump:
Fixing of air vessel of the following.
specifications
a. Diameter : 200 mm
b. Shell Thickness: 8 mm
c. Dish Ends : 10 mm
d. Height : 1000 mm
e. Finishing: Two coats of red enamal paint over primer out side
and two coats of epoxy coating inside.
f. Material of construction: M.S
g. Test Pressure: 26 Kg/Sq.Cm.
i. Height of supporting legs: 400 mm
j. Quantity Each 1 9520 9520
Note: Contractor should submit general arrangement drawings
before fabrication of vessel and ultrosonic test report to be
submitted on supply of vessel and test to be conducted at the
presence of Plumbing-In-Charge.
3.0 Providing & fixing of pressure switch in M.S. pipe line including
connection etc. as required..(For Terrace Pumps) Nos 1 1481 1481
Note: All valves shall be of PN16 rating
TOTAL "FIRE PUMP & EQUIPMENT" CARRIED TO
SUMMARY 94758
B. FIRE HYDRANT SYSTEM
1 Providing, laying, testing & commissioning of 'C' class heavy duty
MS pipe conforming to IS 3589/IS 1239 including Welding,
fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc.
and fixing the pipe on the wall/ceiling with suitable clamp/support
frame and painting with two or more coats of synthetic enamel
paint of required shade complete as required :
a. 25 mm dia RM 8 463 3700
c. 100 mm dia RM 35 1472 51509
2 Supplying and fixing first-aid Hose Reel with MS construction
spray painted in post office red, conforming to IS 884 complete
with the following as required.
20 mm nominal internal dia water hose thermoplastic (Textile
reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve &
M.S. Pipe and socket.
3 Providing & Fixing of Stanless steel four way fire brigade tank
inlet connection having 63 mm dia instantaneous type inlet and
150 mm dia flange outlet conforming to IS:904 with blank cap and
chain with necessary 150 mm dia MS (heavy duty) pipe and
flanges, nuts, bolts etc. Cost shall include a wall mounted box of
M.S. construction (16 SWG) with glass door (4.0 mm thick) to
house the above mentioned component complete in all respect.
(For Tank Filling).
5 Providing and fixing M.S. structural work fabricated from standard
sections, (MS rounds, angles, channels etc.) including cutting to
size, drilling, welding, including cost of fasteners, clamps in RCC
structural members as directed, including two or more coats of
synthetic paint over one coat of primer after surface preparation
including cutting and making good walls.
6 Supplying and fixing single headed internal hydrant valve with
instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia
with cast iron wheel ISI marked conforming to IS 5290 (Type -A)
with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Stainless steel Set 8 5879 47031
7 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with
63 mm dia male and female couplings duly bound with GI wire,
rivets etc. conforming to IS 636 (type-A) as required :
Stainless Steel (Grade 304) Set 8 4354 34835
8 Supplying & fixing 63 mm dia gun metal short branch pipe with 20
mm nominal internal diameter size nozzle conforming to IS 903
suitable for instantaneous connection to interconnect hose pipe
coupling as required :
Stainless Steel (Grade 304) Set 8 1618 12947
9 Providing & Fixing of standard Fireman's Axe with heavy
insulated handle. Each 8 1232 9856
10 Providing & fixing fire authority approved M.S. shutter (size 1200
(L) x 2100 (H) mm ) made out of 16 gauge M.S. sheet Angle
frame capable of accommodating fire hose reel, fire hydrant,
hose pipe, fittings & accessories. The box shall have a single or
double glazed front glass door (with 4 mm thick glass) with lock &
key arrangement & shall be painted with Fire red as per IS:5,
shade no. 536. (For Internal Hydrant)
11 Supplying, fixing, testing and commissioning of butterfly valve of
PN 1.6 rating with bronze/gunmetal seat duly ISI marked
complete with nuts, bolts, washers, gaskets conforming to IS
13095 of following sizes as required :
100 mm dia Set 8 6349 50794
80 mm dia Set 1 4761 4761
12 Providing, installation, testing and commissioning of non-return
valve of following sizes confirming to IS: 5312 complete with
rubber gasket, GI bolts, nuts, washers etc.as required :
100 mm dia Each 1 10640 10640
13 Providing and fixing in position the industrial type pressure
gauges with gun metal / brass valves complete as required
Note: All valves shall be of PN16 rating 0 0
TOTAL "FIRE HYDRANT SYSTEM" CARRIED TO SUMMARY
C. PORTABLE FIRE EXTINGUISHERS 0 0
1 Providing and fixing Carbon-di-oxide fire extinguishers consisting
of welded M.S cylindrical body,squeeze lever discharge valve
fitted with internal discharge tube, ISI marked high pressure
discharge hose, discharge nozzle, suspension bracket,
confirming to IS : 15683 finished externally with red enamel
paint and fixed to wall with brackets with rawl plug/dash
fasteners complete with internal charge with CO2 gas conforming
Capacity 4.5 kg. I.S.I. Marked. (IS : 15683 : 2006) Each 15 10883 163246
2 Providing and fixing ABC stored pressure dry chemical powder
(mono ammonium phosphate) Fire Extinguisher IS : 15683 latest
revision manufacturer and of CRCA sheet in welded
construction, finish with High quality epoxy polyster powder
coated complete with brass forged ball valve, gun metal cap and
nozzle, including initial filled and wall suspension bracket
(suitable for fighting in class 'A', B & 'C' that is wood, textile,
flammable liquid, electric and gases).
Capacity 6 Kg (IS : 15683 : 2006) Each 15 6150 92249
TOTAL "PORTABLE FIRE EXTINGUISHERS" CARRIED TO
SUMMARY
D. ELECTRICAL INSTALLATION FOR FIRE FIGHTING SYSTEM
1 Design, manufacture, assembly, wiring, testing at works and
supply to site of following panels/distribution boards/switch
boards. The boards shall be designed and fabricated as per
general specifications, technical details, specifications and notes
as part of this tender /BOQ and relevant BIS codes.
FIRE PUMP PANEL
IP Rating: IP 54
Incomer :
1 No. 32 A, 10 KA, 4P MCB of motor duty
Incomer Metering & Indication:
415V / √3 / 110V/ √3 PT's, Cast Resin type, 3 Phase for
metering & indications, suitable rated 6A, TP MPCB of the fault
withstand capacity as of the panel on the primary side of PT &
suitable rated 6A, TP MCB on the secondary side of PT.
R,Y,B phase indication lamps (110V) LED Type
ON' & Trip indication lamps (110V) LED Type
Cast resin metering CT's for each phase of class-1 accuracy & of
suitable burden & ratio
1 No. Digital VAF + PF Meter (110V) (With RS 485 Port)
Bus bars:
100A, 4 P, Aluminium Bus Bars of Electrolytic grade with heat
shrinkable sleeves 35 KA.
Control Transformer & Control Circuiting for Starters / Contactors
& Indication Lamps :
2 Nos. 415V / 55-0-55V Cast resin Dry type control transformers
of adequate 'VA' burden to take care of load of all the contactor
coils with a auto changeover circuiting & mechanism for full proof
auto & manual change over from one control transformer to
second control transformer incase of one going faulty.
(Transformer with primary taps at ± 2.5%, ± 5%, 50 Hz, centre
tap earthed).
Suitable rated 6A, DP, MPCB of the fault withstand capacity as of
the panel for control circuiting for contactors coils on the primary
side of control transformer & suitable rated 6A, DP MCB on the
secondary side of control transformer.
110V Control circuiting
Power Contactors for auto changeover of control transformers
110V Control supply healthy indication (LED Type)
Outgoings:
a. Star-Delta Starter comprising the following (for Terrace Pump):
For 10 HP. (1 Nos.) (Terrace Pump)
Type-2 Co-ordination
1 No. suitable rated TP MCB, 10 KA, (Motor duty only magnetic /
microprocessor based motor duty ).
Suitable sized 3P Contactors (Star, Delta & Run contactors) with
2 NO & 2 NC Auxiliary contacts
Star-Delta Timer
Suitable Electronic O/L motor protection relay with inbuilt SPP
ON/OFF / Trip indication lamps (110V) (LED Type)
ON/OFF Push buttons
Suitable rated cast resin CT's for metering on each phase, of
Class-1 accuracy and of suitable burden & ratio
ON/OFF-Trip / A/M potential free contacts for BMS
Control wiring for linking with pressure switch for auto operation.
Fire pump panel to be complete with all control wiring / terminals
for linkage with flow switches / pressure sensor for auto operation
of pumps and as per the requirement of Local Govt. Fire Officer.
Fire Pump Panel as described above. Set 1 22400 22400
2.0 Supply, installation, testing & commissioning of following sizes of
1100 V grade PVC Aluminium armoured cables, PVC insulated
PVC sheathed, including cable trays /supports as per site
conditions.
3.0 Control Cable:
Supply and laying of 2C x 1.0 Sq.mm copper armoured cable
including termination. (Control cable shall be paid separately
under control cable head). RM 30 134 4032
4.0 Cable Termination:
Supplying and making end termination with brass compression
gland and aluminium lugs for following size of PVC insulated and
PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade as required.
b. 3C X 10 Sq.mm Each 2 236 473
5.0 Body earthing of the various equipments/ motors/ switchgears
supplied by the bidder with suitable size of earthing strip/wire etc.
as per IS:3043 and as required including provision for connection
of earthing to main earthing pits.
(G.I earth strip of size 25 mm x 6 mm). RM 50 235 11760
TOTAL "ELECTRICAL INSTALLATION FOR FIRE FIGHTING
SYSTEM" CARRIED TO SUMMARY
TOTAL FOR FIRE FIGHTING 874,463.03
SCHEDULE OF QUANTITIES / BUDGETARY COST ESTIMATE
Rourkela Circuit House, ODISHA
FIRE DETECTION AND ALARM SYSTEM - ANALOG ADDRESSABLE
TOTAL RATE
S.No. DESCRIPTION UNIT RATE AMOUNT
QTY. (Rs.)
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm
unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) an
per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display w
keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 %
with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect p
facility to have seamless integration with analog/digital voice evacuation system ( which is part of the schedul
System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open
over IP complete as per specifications.
MANUAL CALL POINT
1 Supply, installing, testing &
commissioning of addressable
Manual call point (Pull station-
double action).
DUAL TONE HOOTERS
2 Supplying, installation, testing &
commissioning of addressable horn
cum strobe complete as required. Nos. 9 3,041 3,406 30,656
FAULT ISOLATOR - -
3 Supply, installing, testing and
commissioning of addressable type
Fault Isolators for isolating shorted, Nos. 1 4,057 4,544 4,544
de wired and loose circuits between
two successive fault isolators with
automatic resetting arrangement.
CONTROL MODULES - -
4 Supply, installing, testing and
commissioning of addressable and
automatic commandable control Nos. 9 9,725 10,892 98,032
modules for:
Fireman's Telephone jack circuits - -
Hooters / Speakes/ Strobe Circuit - -
MONITOR MODULES - -
TOTAL RATE
S.No. DESCRIPTION UNIT RATE AMOUNT
QTY. (Rs.)
5 Supply, Installation, testing and
commissioning of Addressable
Monitor modules for :
Sprinkler flow switches
Water leak detection monitoring
Any other monitoring point or third
party circuit integration
FIRE ALARM CONTROL PANEL
6 Supply, installting, testing and commissioning of Microprocessor based intelligent and
electronically addressable, modular, expandable, networkable, Fire Alarm Control Panel with
minimum 6 inch / 640 character LCD display, multiple access levels, event history file in non-
volatile memory (EEPROM). The panel shall support programmable relays for controlling lifts, fire
pump, monitoring of fire sprinkler and fire hydrant pump controlled by powerful Boolean logic
equation. The panel shall have 240 volts AC power supply, automatic battery charger, 24 volts,
sealed lead acid maintenance free batteries sufficient for 24 hours normal working and then be
capable of operating the system for 60 minutes during emergency condition. The panel shall be UL
listed 9th Edition
2 Loop Nos. 1 213,178.4 238,760 238,760
HEAT DETECTOR 0 3,296 3,692 -
7 Supply, installing, testing and
commissioning of UL listed
addressable intelligent rate of rise
thermistor type resettable Heat - -
detector with mounting base, dual
LED, complete with base as required.
8 SMOKE DETECTOR - -
8.1 Supplying, installation, testing &
commissioning of smoke detector with
builtin LED and mounting base Nos. 140 1,122 1,257 175,946
complete with all connections etc. as
required.
8.2 Supplying, installation, testing &
commissioning of central graphical
fire alarm management system to
centrally monitor and operate the fire
alarm system complete as required
9 CABLE AND CONDUIT - -
TOTAL RATE
S.No. DESCRIPTION UNIT RATE AMOUNT
QTY. (Rs.)
9.1 Supply & laying in exisiting MS
conduits, 2x1.5 sq.mm 1100V grade
FRLS insulated, PVC sheathed
copper conductor wire including
terminations, connections & all labour
and material etc.complete as required
(For fire detection signal, for fire loop,
for speakers, for tele jacks).
9.2 Supply & laying in exisiting MS
conduits, 2x1.5 sq.mm 1100V grade
FRLS insulated, PVC sheathed
copper conductor wire including
terminations, connections & all labour RM 45 55 62 2,772
and material etc.complete as
required. (For Hooters / Strobes
power).
9.3 Supplying and fixing of following sizes
of steel conduit along
with accessories in surface/recess
including painting in case of surface
conduit, or cutting the wall and
making good the same in case of
recessed conduit as required.
Total Carried to Summary 1,006,990
SCHEDULE OF QUANTITIES/ BUDGETARY COST ESTIMATE
HVAC Works - Circuit House, Rouekela
Description Unit Qty. RATE AMOUNT
SPLIT AIRCONDITIONERS
Supply, Transportation, Installation, Testing and Commissioning
of the following Inverter model Cool type Split AC unit with high
wall mounted Single Split indoor unit and outdoor condensing
unit Hermetically sealed compressor suitable for operation on
230V, 50Hz, 1Phase AC supply capable of performing Heat cool
1 dehumidifying air circulating and filtering with cooling and
condensing units with 3 mts of copper piping, insulation kit and
4 mts of 4 core copper flexible chord with cordless remote
control etc., dual barrier coating in order to protect coil form
oxidigation.
[Make: O General / Hitachi / MITSUBISHI ELECTRIC]
1.0 TR 3 star capable of delivering 12000 BTU/hr and above with
1.1 operating on refrigerant R-32/ R-410A, COP not less than 4.5. Each 2 39928.00 79856.00
1.5 TR 3 star capable of delivering 18000 BTU/hr and above with
1.2 operating on refrigerant R-32/ R-410A, COP not less than 4.5. Each 32 47081.44 1506606.08
2.0 TR 3 star capable of delivering 24000 BTU/hr and above with
operating on refrigerant R-410A / R-32.
CASSETTE TYPE AC UNITS 0.00 0.00
Supply, Transportation, Installation, Testing and Commissioning
of the following Cassette type AC unit with ceiling mounted
indoor unit and outdoor condencing unit Hermetically
compressor suitable for operation on AC supply capable of
performing cooling dehumidifying air circulating and filtering
with cooling and condensing units etc. complete with Wireless
remote controller, without refrigerent piping and cable.
[Makes: O General / Hitachi / MITSUBISHI ELECTRIC]
2.0 TR 4 star Three Phase capable of delivering 24000 BTU /hr
and above with operating on refrigerant R-32 / R-410A.
3.0 TR 4 star Three Phase capable of delivering 36000 BTU / hr
2.2 and above with operating on refrigerant R-32 / R-410A. Each 2 97409.76 194819.52
4.0 TR 4 star Three Phase capable of delivering 48000 BTU /hr
and above with operating on refrigerant R-32 / R-410A.
CEILING CONCEALED TYPE AC UNITS 0.00 0.00
Supply, Transportation, Installation, Testing and Commissioning
of the following inverter type Ceiling concealed type AC indoor
unit and outdoor condencing unit Hermetically compressor
suitable for operation on AC supply capable of performing
cooling dehumidifying air circulating and filtering with cooling
and condensing units etc. complete with Wireless remote
controller, without refrigerent piping and cable.
3.1 4.0 TR Nominal Capacity Each 2 102821.60 205643.20
Supply, Fabrication of 1 set MS bracket suitable for fixing out
door unit of split AC unit.
Rudrabhishek Enterprises Pvt. Ltd. (REPL) 2
Description Unit Qty. RATE AMOUNT
Supply, Installation, testing and commissioning of following
nominal sizes of soft/ hard drawn copper refrigerant piping for
suction and liquid between indoor and outdoor unit for split/
Casseete Air-Conditioner including foaming etc., complete
including insulated with 13mm/9mm XPLE Class-O tubular
5 insulation/ with Class-O closed cell elastometric nitrile rubber 0.00 0.00
tubular sleeves sections of specified thickness as given below for
Suction and Liquid lines.
Make: Copper:Totaline /Nippon /Mandev.
Nitrile Insulation: Kflex/ Totaline /HIRA
5.1 6.4 mm dia (OD) One RM 1069 440.16 470522.24
5.2 9.5 mm dia (OD) One RM 55 703.36 38762.17
5.3 12.7 mm dia (OD) One RM 613 912.80 559975.42
5.4 15.9 mm dia (OD) One RM 593 1021.44 605948.85
5.5 19.1 mm dia (OD) One RM 193 1528.80 294798.50
Supply, installation and testing of UPVC Drain piping with 6 mm
Nitrile Rubber class "O" Insulation covered with interwoven glass
cloth protection. Necessary pipe fittings (Including enlarger,
6 bends, T Joints etc) has to be considered to connect the UPVC 0.00 0.00
drain pipe to nearest drain point.
Make: Copper: Ashirwad /Astral /Supreme.
Nitrile Insulation: Kflex/ Totaline /HIRA
6.1 20 mm dia One RM 350 249.76 87416.00
6.2 25 mm dia One RM 250 286.72 71680.00
6.3 32 mm dia One RM 150 331.52 49728.00
Rectangular Ducting (Factory Made) 0.00 0.00
Supply, installation, balancing and commissioning of factory
fabricated GSS sheet metal rectangular/round ducting complete
with neoprene rubber gaskets, elbows, splitter dampers, vanes,
hangers, supports etc. as per approved drawings and
specifications of following sheet thickness complete as required.
Duct Insulation 0.00 0.00
Supplying and fixing of external thermal insulation on ducts
with Cross Linked Closed Cell Polyethylene FR-XPE, density
8 33±3kg/cum, Class O fire rating insulation, tape & adhesive 0.00 0.00
(pidilite SR -998) as required of following thickness.
8.1 13 mm thick Aluminium Metalized Insulation SMT 30 581.28 17438.40
Acoustic Lining of Duct 0.00 0.00
Supplying and fixing of acoustic lining of duct with fibre glass
rigid board of density 48 Kg/m³ sealed in fibre glass tissue
9 paper and covered with 0.5 mm thick perforated aluminium 0.00 0.00
sheet and conforming to specification given in the tender.
9.1 12 mm thick fibre glass rigid board. SMT 10 1515.36 15153.60
Propeller Fans 0.00 0.00
Rudrabhishek Enterprises Pvt. Ltd. (REPL) 3
Description Unit Qty. RATE AMOUNT
Supply, installation, testing and commissioning of propeller
exhaust fans of various capacities as given below suitable for
8 240 volts, 50 Hz, single phase AC supply complete with gravity 0.00 0.00
louvers & speed regulator etc.
8.1 100 CFM, 5 mm St. Pr. NO 37 11634.56 430478.72
8.2 300 CFM, 5 mm St. Pr. NO 4 13258.56 53034.24
8.3 500 CFM, 5 mm St. Pr. NO 4 20023.36 80093.44
Grilles, Diffusers, VCD etc 0.00 0.00
Supply & fixing of powder coated extruded aluminium
9 Continouous type linear grilles complete with nut, bolts, screws SMT 2.0 6731.20 13462.40
etc. as per approved drawings and specifications.
Supply & fixing of powder coated extruded aluminum black
anodized extruded aluminium VCD (Collar Damper wherever
specified) with nut, bolts, screws etc. as per approved drawings
and specifications.
Supply, installation, testing and balancing of Eye-Ball Nozzles
(adjustable) of following dia
11.1 315 mm dia NO. 8 8387.68 67101.44
Supplying and laying of PVC/XLPE insulated Copper conductor
armored cables of 1.1KV grade of following sizes directly on
wall/ structural frame/ cable trays or racks using approved type
of clamps, double earthing with GI strip/ wire of suitable size
and hardware all complete as per equipment specifications,
drawings and direction of EIC.
12.1 2.5 Sqmm 4 Core copper flexible cable RM 150 116.48 17472.00
12.2 4 Sqmm 4 Core copper flexible cable RM 1000 154.56 154560.00
12.3 4 Sqmm 4 Core copper armored cable RM 100 539.84 53984.00
12.4 6 Sqmm 3 Core copper armored cable RM 100 630.56 63056.00
Supplying and laying earth connection from earth electrode with
6 SWG dia G.I. wire for loop earthing as required.
Grand Total For HVAC Works 8,432,449.63
Grand Total For HVAC Works 8,432,449.63
Rudrabhishek Enterprises Pvt. Ltd. (REPL) 4
FURNITURE & OTHER ITEMS FOR RESIDENTIAL
DESCRIP-TION LOCATION UNIT QTY. RATE TOTAL AMOUNT
DESCRIP-TION LOCATION UNIT QTY. RATE TOTAL AMOUNT
1 43 INCES LED TV VIP ROOMS EACH 8 38080 304640
2 32 INCES LED HD TV EXECUTIVE ROOMS EACH 30 8958.88 268766.4
RUG /CARPET 6'-0''X6'-0''
3 VIP ROOMS EACH 8 2419.2 19353.6
(@90 PER SQFT =2160 RS)
RUG /CARPET 4'-0''X4'-0''
4 EXECUTIVE ROOMS EACH 30 1075.2 32256
(@60 PER SQFT =960 RS)
EXECUTIVE ROOMS, AND ALL
5 DOOR MAT EACH 60 168 10080
TOILETS
6 DOOR MAT VIP ROOMS EACH 8 504 4032
7 REFRIGERATOR VIP ROOMS EACH 8 13204.8 105638.4
8 IRON PRESS VIP ROOMS EACH 4 1120 4480
9 IRON TABLE VIP ROOMS EACH 4 1678.88 6715.52
EXECUTIVE ROOMS , VIP
ROOMS , HOUSE KEEPING , VIP
DINING , PUBLIC DINING
10 LANDLINE PHONE EACH 44 616 27104
,RECEPTION ,PUBLIC
RECEPTION ,CONFERRENCE
ROOMS , GYM
EXECUTIVE ROOMS, VIP
11 TOWEL EACH 100 313.6 31360
12 Plastic Mug Executive Room ,VIP Roms EACH 34 31.36 1066.24
13 Plastic bucket Executive Room ,VIP Roms EACH 34 161.28 5483.52
Executive Room ,VIP Roms
14 Dustbins ,conferrence room , meeting EACH 50 1043.84 52192
rooms ,receptions ,dining etc
Royaloak Penaing Malaysian
15 King Size Bed in Melamine Executive Room EACH 30.00 22400 672000
Finish
Royaloak Kiwi Dresser with
16 Storage and Mirror in Executive Room EACH 30.00 8400 252000
Embossed Finish
Royaloak Dolphin 2 Door
17 Wardrobe in Melamine Executive Room EACH 30.00 13440 403200
Finish
Royaloak Mourya King Size
18 VVIP Room EACH 4.00 48160 192640
Bed in Sheeshom Wood
Royalaok Drogo Dresser in
19 VVIP Room EACH 4.00 15680 62720
Melamine Finish
Royaloak Johor Malaysia 3
20 Door Wardrobe in Melamine VVIP Room EACH 8.00 23520 188160
Finish
Royaloak Nario Glass
21 Bookshelf in Melamine VVIP Room EACH 4.00 15120 60480
Finish
Royaloak Archer side Table
22 VVIP Room EACH 8.00 3584 28672
in Melamine Finish
Royaloak Archer side Table
23 VVIP EACH 8.00 2800 22400
in Melamine Finish
24 Royaloak Miami Corner Sofa VVIP & Executive Room EACH 34.00 43680 1485120
Royaloak Atom Center Table
25 VVIP & Executive Room EACH 34.00 8400 285600
in Sheesham Wood
Royaloak Madina LHS
26 VVIP Room EACH 4.00 68443.2 273772.8
Shape Sofa in Leatherette
Royaloak Geneva Glass
27 VVIP Room EACH 4.00 32480 129920
Dining 6S
Royaloak Alan Computer
28 VVIP & Executive Room EACH 34.00 9520 323680
Royaloak Caspian Meeting
29 VVIP Room EACH 4.00 25760 103040
Table in Melamine Finish
30 Royaloak Mica TV Stand Executive Room EACH 30.00 11088 332640
Royaloak Conor TV Unit
31 VVIP Room EACH 8.00 19040 152320
Teak in Sheesham Wood
Eleganite Homez Grafton
32 VVIP & Executive Room EACH 38.00 6708.8 254934.4
square ottoman
33 Black Churchill Shoe Rack VVIP & Executive Room EACH 1.00 4704 4704
Ergo Mesh Office Chair
34 VVIP & Executive Room EACH 54.00 4592 247968
(Chennai Chairs)
35 Recliner VVIP Room EACH 4.00 56000 224000
FurnitureKraft Berlin Metal DORMITORY IN EXISTING
36 Single Bed (Finish Color - BUILDING EACH 20.00 6048 120960
Black)
37 BLANCKETS VIP EACH 16.00 1064 17024
38 BLANCKETS Executive Room and dormitory EACH 100.00 1600.48 160048
DORMITORY IN EXISTING
39 BED SHEETS BUILDING EACH 40.00 201.6 8064
DORMITORY IN EXISTING
40 Matress BUILDING EACH 20.00 1064 21280
Royaloak Aura Banana
41 Outdoor Sofa 3 Seater in OUTDOOR FURNITURE EACH 6.00 17920 107520
Teak Wood
42 Royaloak Troy Set in Rattan VVIP (Balcony Sitting) EACH 4.00 21168 84672
43 Chandeliar VIP ENTRANCE LOBBY EACH 1.00 50400 50400
44 BED SHEET Executive Room EACH 1.00 616 616
FOR EXECUTIVE AND VIP
45 PILLOWS EACH 68.00 215.04 14622.72
ROOMS AND DORMITORY
46 BED SHEET VIP SUITS EACH 8.00 2016 16128
47 Matress EXECUTIVE ROOMS EACH 30.00 8400 252000
48 Matress VIP SUITS EACH 4.00 28000 112000
49 COAT STAND VIP ROOMS EACH 4.00 2688 10752
50 FLOOR LAMP VIP ROOMS EACH 4.00 6720 26880
51 METAL HANGINIG LAMPS VIP DINING EACH 12.00 896 10752
52 ELECTRIC KETTLE VIP ROOMS EACH 4.00 2047.36 8189.44
EXECUTIVE ROOMS , VIP
ROOMS , RECEPTION , DINING
53 WALL CLOCK EACH 40.00 1428 57120
,PUBLIC RECEPTION , WAITING
LOUNGE .
54 TABLE LAMPS VIP ROOMS EACH 8.00 14896 119168
TOTAL 7,771,335.04
FURNITURE & OTHER ITMES FOR OFFCIE
S.NO. DESCRIPTION LOCATION UNIT QTY RATE TOTAL AMOUNT
S.NO. DESCRIPTION LOCATION UNIT QTY RATE TOTAL AMOUNT
Storage Systems
Rectangular Office Executive Meeting
Conference Table 8 Room Table
Seater
Wooden
VVIP Small
Rectangular Office
2 Meeting Room EACH 1.00 35,840.00 35,840.00
Conference Table
6 Seater
VJ Interior Medium VVIP Meeting
3 Back Leatherette Room Chair and EACH 32.00 11,116.00 355,712.00
Revolving Chair Office Table Chair
VJ Interior High
VVIP Meeting
4 Back Leatherette EACH 1.00 17,948.00 17,948.00
Room Chair
Revolving Chair
Wallet Office Table
5 Office EACH 5.00 19,040.00 95,200.00
(Chennai Chairs)
Xenium Executive
6 Desk 6 Ft (Chennai Office EACH 1.00 29,456.00 29,456.00
Chairs)
Meeting Room,
Ergo Mesh Office
Office,
7 Chair (Chennai EACH 45.00 4,592.00 206,640.00
Reception,Commo
Chairs)
n Room etc.
20 Seater
Conference Table VIP Conference
(Ashithesh Room Table
Enterprices)
Arcwood optional Executive Entrance
Reception Table Lobby
Shivam Wooden
VVIP Entrance
10 Modern Reception EACH 1.00 53,312.00 53,312.00
Furniture
Wood Craft Black VVIP & Executive
Office Sofa Ste Waiting lobby
12 Décor Sofa set VVIP Waiting EACH 4.00 72,800.00 291,200.00
Royaloak Milan
13 Glass Dining 4 Executive Dining EACH 3.00 17,920.00 53,760.00
Seater
Royaloak Country 6
Seater Dining set
VVIP & Executive
14 with tempered glass EACH 6.00 29,120.00 174,720.00
Dining
top & veneer finish
6 seater
Wooden 10 Seater
15 Dining Table VIP Dining EACH 1.00 53,760.00 53,760.00
(Indiamart)
BH Fitness BT 6441
16 T100 Home GYM EACH 2.00 69,552.00 139,104.00
Treadmill
BH Fitness G2334N
17 GYM EACH 2.00 44,352.00 88,704.00
ATHLON SERIES
18 Budha statue landscape court EACH 1.00 28,000.00 28,000.00
meeting room and
19 projector screen EACH 2.00 14,000.00 28,000.00
conferrence room
meeting room and
20 LED Projector EACH 2.00 14,000.00 28,000.00
conferrence room
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Annexure-A-Declaration_EMD.pdf
Tender Document
Approved Make List-CIRCUIT HOUSE.pdf
Tender Document
Circular_No_NBCCCE2020CIRCULAR20_Dtd27_11_2020.pdf
Tender Document
Drawings006-Combined.pdf
Tender Document
GCC_Contracting_2019 with-Amendment 1to5.pdf
Tender Document
Instruction to Bidder.pdf
Tender Document
Intergrity Pact.pdf
Tender Document
Notice Inviting Tender 006.pdf
Tender Document
Technical Specification-Electrical 006.pdf
Tender Document
Technical Specifications-CivilandPHE 006.pdf
Tender Document
CS_cover_2_BOQ006NBCCBBSR2021.xlsx
Tender Document
BOQ-13_04_21.pdf
Tender Document
corrigendum-138-Price bid opening01.pdf
pdf • 0.17 MB
corrigendum-137-Price bid opening.pdf
pdf • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .