Superintending Engineer (CG), GIDC, Bharuch.
Construction of New Office Building at GIDC, Vadodara.
314283
E-Tender Notice No. 03 of 2026-27 Sr. No. 14
Open
Civil - All
Vadodara
2 documents required · 2 mandatory
₹14,160
Executive Engineer, GIDC, Baroda
₹10.0 L
20 Jun 2026
20 Jun 2026
20 Jun 2026
6 Jul 2026
20 Jun 2026
Description Qty. Unit Rate Amount
1 Clearing and grubbing road land including 0.76 Hectare 34889.38
uprooting of rank vegetation, grass, brushes,
shrubs, wood, trees and saplings of girth upto
300mm removal of stumps of trees cut earlier
and disposal of unserviceable materials (D) By
mechanical means in area of thorny jungle with
all lead and lift as directed by Engineer in
2 Excavation for foundation in Loose or Soft soil 2496.00 Cumt. 120.01
upto 1.50m depth including sorting out and
stacking of useful materials and disposing of the
excavated stuff with all lead and lift as directed
by Engineer in charge.
3 Excavation for foundation in Loose or Soft soil 2496.00 Cumt. 133.05
from 1.50 m. to 3.00 m. depth including sorting
out and stacking of useful materials and
disposing of the excavated stuff with all lead and
lift as directed by Engineer in charge.
4 Excavation for foundation in Loose or Soft soil 1414.00 Cumt. 146.09
from 3.00 m. to 5.00 m. depth including sorting
out and stacking of useful materials and
disposing of the excavated stuff with all lead and
lift as directed by Engineer in charge.
5 Earthwork for embankment including breaking 3770.00 Cumt. 173.67
clods, dressing with all lead and lift and
including watering rolling and consolidation of
subgrade in layers at O.M.C. to required dry
density including filling the depression which
occur during the process using power roller 8T
to 10T.(E) From Borrow area within 3.0KM. lead
6 Filling available excavated earth in trenches. 4616.00 Cumt. 133.66
plinth, sides of foundations etc. in layers not
exceeding 20cm. In depth consolidating each
disposited layer by ramming and watering etc.
complete as directed by Engineer in charge.
7 Providing and laying Rubble soling with sand in 162.00 Cumt. 1464.6
foundation below PCC and watering and
compacting the same etc. completed.
Description Qty. Unit Rate Amount
8 Anti-Termite System: Providing and laying of 3996.00 Sqmt. 63.63
permanent piping technology anti-termite
treatment before flooring work by installing
LLDP (Low linear density polyethylene) tube of
8 mm O.D. & 6.4 mm I.D. with inbuilt pressure
compensation chip every 30 cm interval in the
tube, having working pressure of 2 Kg/cm2 and
release rate of 1.9 ltr/hour fixed by P-clips and
nails. The LLDP pipe shall be installed at the
entire periphery of the building and at internal
network of building at a depth of 20 to 200 mm
under floor at every 2 to 3 mtr. c/c distance
(adjusted as per building layout) & ends of loop
pass through a PVC elbow of minimum 32 mm
ID at junction box of wall and floor level,
entering into a steel reinforced grooved flexible
pipe of minimum 22 mm ID leading into junction
box and the loops shall terminate in junction
boxes & test every junction during injecting
chemicals for termite control treatment. The
piping shall be covered with cement mortar/PCC
for protection. The anti termite chemical
Imidacloprid 30.5% SC mix as per IS-6313 (part
III) shall be injected by the pressure pump
diluted with water @ 10.5 ml/5 ltr of water at
the rate of 2 Kg/sq.cm @ 5 Ltr/SMT. The
9 contractor shalllaying
Providing and submitPCC
1:3:6 line plan for:
(1-cement 74.00 Cumt. 3231.78
coarse sand : 6 M/c stone aggregate 20 / 40mm
nominal size) in foundation concrete / floor
concrete incl. machine mixing, ramming,
consolidation & curing etc. incl. cost of form
work if required etc. complete at all levels as
directed by Engineer in charge.
10 Providing and laying controlled cement concrete 544.00 Cumt. 4493.54
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete at all levels
for RCC FOOTING
11 Providing and laying controlled cement concrete 132.00 Cumt. 7282.35
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete COLUMN UP
TO GROUND FLOOR LEVEL & FIRST FLOOR
Description Qty. Unit Rate Amount
12 Providing and laying controlled cement concrete 130.00 Cumt. 7322.29
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete COLUMN AT
ALL FLOOR LEVEL
13 Providing and laying controlled cement concrete 8.00 Cumt. 13993.5
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete at RCC
Double height Columns at all floor level .
14 Providing and laying controlled cement concrete 162.00 Cumt. 6591.15
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc.complete FOR RCC
BEAM UP TO GROUND FLOOR LEVEL & FIRST
15 Providing and laying controlled cement concrete 126.00 Cumt. 6631.1
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc.complete FOR RCC
BEAM AT ALL FLOOR LEVEL
16 Providing and laying controlled cement concrete 4.00 Cumt. 14670.78
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete AT RCC
Double height BEAMS at all floor level .
Description Qty. Unit Rate Amount
17 Providing and laying controlled cement concrete 352.00 Cumt. 6266.96
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete at all levels
for RCC SLAB at GROUND FLOOR & FIRST
18 Providing and laying controlled cement concrete 126.00 Cumt. 6306.91
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete for RCC
SLAB AT ALL FLOOR LEVEL
19 Providing and laying controlled cement concrete 6.00 Cumt. 11153.7
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete at all levels
for RCC SLAB (Double height )
20 Providing and laying controlled cement concrete 80.00 Cumt. 7587.91
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete at all levels
for RCC SILL and LINTEL & Coping
21 Providing and laying controlled cement concrete 44.00 Cumt. 7219.75
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete at all floor
levels for RCC STAIRCASE
Description Qty. Unit Rate Amount
22 Providing and laying controlled cement concrete 38.00 Cumt. 6635.81
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete for RCC
WALL UP TO GROUND FLOOR & FIRST FLOOR
23 Providing and laying controlled cement concrete 22.00 Cumt. 6675.75
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete at all levels
for RCC WALL AT ALL FLOOR LEVEL
24 Providing TMT Bar FE 500D reinforcement for 261310.00 KG 77.29
R.C.C. work including bending, binding and
placing in position complete upto floor two level.
(For all Floors)
25 Providing and fixing 200 mm wide, approved 312.00 Sqmt. 251.7
quality chicken wire mesh at junction of brick
work and RCC work or two dissimilar surfaces,
at all heights fixed by nails, rowal plugs or tag by
cement mortar 1:3 before applying the plaster,
including curing, scaffolding all complete as
26 Brickwork using common burnt clay building 26.00 Cumt. 4121.55
bricks having crushing strength not less than
Kg./Sq. Cm. in foundation and plinth in cement
Mortar 1:6 (1-Cement : 6 - fine sand).
Conventional in Foundation & Plinth (Upto
27 Brickwork using common burnt clay building 374.00 Cumt. 4403.4
bricks having crushing strength not less than
Kg./Sq. Cm. in foundation and plinth in cement
Mortar 1:6 (1-Cement : 6 - fine sand). GROUND
& FIRST FLOOR (Upto 10 ton).
28 Brickwork using common burnt clay building 214.00 Cumt. 4444.59
bricks having crushing strength not less than
Kg./Sq. Cm. in foundation and plinth in cement
Mortar 1:6 (1-Cement : 6 - fine sand). SECOND
FLOOR & TERRACE FLOOR(Upto 10 ton).
Description Qty. Unit Rate Amount
29 Half brick masonry in common brunt clay 586.00 SQMT 734.46
building bricks having crushing strength not less
than 35 Kg / Sq.Cm. in Cement mortar 1:3 (1-
Cement:3-coarsesand) with 2 Nos of 6mm Mild
steel round bars after every three course
embedded in Cement Mortar in Conventional in
GROUND & FIRST FLOOR
30 Half brick masonry in common brunt clay 542.00 SQMT 740.61
building bricks having crushing strength not less
than 35 Kg / Sq.Cm. in Cement mortar 1:3 (1-
Cement:3-coarsesand) with 2 Nos of 6mm Mild
steel round bars after every three course
embedded in Cement Mortar in Conventional in
31 Providing 10mm thick cement plaster in single 2950.00 SQMT 145.12
coat on brick/concrete walls/ceiling for interior
plastering for all floor levels and finished even
and smooth in (i) Cement mortar 1:3 (1 cement :
32 Providing 15mm thick Cement Plaster in single 5762.00 SQMT 198.6
coat on brick/concrete wall for interior
plastering upto floor two level finished even and
smooth in Cement mortar 1:4 (1-cement :4-
sand) at all floor level
33 20mm thick sand faced cement plaster on walls 4164.00 SQMT 337.53
upto height 10 metres above ground level
consisting of 12mm thick backing coat of C.M.
1:3 (1-cement : 3-sand) and 8mm thick finishing
coat of C.M. 1:1 (1-cement : 1-sand) etc.
34 Providing 20 mm thick Water Proof cement 174.00 SQMT 306.96
plaster for sunk in single coat on brick /
concrete wall for interior plastering up to floor
two level finished even and smooth ( ii )Cement
mortar 1:3 ( 1-cement ,3- sand ) and mixing
waterproofing materials of approved brand
(sika) and manufacture in cement mortar in
proportion recommended by the manufacturer
35 Providing and laying brickbat cement concrete 174.00 SQMT 133.59
1:5:10 (1-Cement:5-finesand:10-graded
brickbat aggregates 40mm nominal size) and
curing complete including waterproofing
material - for toilet floor at all levels
Description Qty. Unit Rate Amount
36 Providing and laying intergrated cement based 1122.00 SQMT 979.82
proprietary water proofing treatment of
required thickness over the roof including
10mm thick waterproofing cement plaster in
cement mortar 1:3 and CHINA MOSAIC fitting
and finally finishing the surface with white
cement slurry and sloping out terrace slabs with
following specification laid to required slope not
flattar than 1:80 (the thickness of water
proofing treatment near rainwater outlet or the
lowest point of the finished slope shall not be
less than 45mm including treating the vertical
surface of the parapet wall up to 20cms height
above finished level of terracing including
finishing the top with joint less water proofing
plaster, curring testing etc complete Rate is
including ten years performance of guarantee
bond to be given on stamp paper ( No extra shall
be paid for increase in thickness for proper
slope(A)Applying and grouting a slurry coat of
neat cement using 2.75 kg/sqm of cement
admixed with proprietary water proofing
compound conforming to IS-2645 and 10mm
thick water proofing cement plaster in cement
Mortar 1.3 over the RCC slab including cleaning
the surface before treatments.
37 (B) Laying cement
Providing concrete
& laying using broken
full body brick
Vitrified tiles 2050.00 SQMT 1748.69
flooring over 20 mm (average) base of cement
mortar 1:6 ( 1 cement: 6 coarse sand) on new
surface or fixing on existing flooring by adhesive
material including dismentaling of existing
flooring and jointed with color cement slurry
including Making 3mm spacer at joint of tiles
and fill the spacer with epoxy jointing material
,finised with flush pointing & cleaning the
surface etc complete selection as directed by
Architect/Engineer in Charge.( Size: 1.20Mt. X
38 Providing and fixing Fullbody vitrified tiles 914.00 SQMT 1381.87
(dado work) of size 1200 mm × 600 mm on wall
surface using approved polymer-based chemical
adhesive, including dismantling of existing finish
where required, surface preparation, fixing tiles
in true line, level and alignment, maintaining
mm joints with spacers, filling joints with epoxy
jointing material, finishing with flush pointing
and cleaning complete, as directed by
Architect/Engineer-in-Charge. ( Size -1.20Mt. X
0.60 Mt.) make:Sommany,Nitco,Kajariya
Description Qty. Unit Rate Amount
39 Providing and laying 18mm thick polished 278.00 SQMT 1954.3
GRANITE STONE SLAB flooring ,trade of step
,riser of step Laanding , door sill (umra) on
20mm (average) thick base of cement mortar
1:6 (1 cement : 6 course sand) laid over and
jointed with coloured cement slurry including
rubbing and polishing and including making half
round moulding to toe of treads etc.. complete as
directed by Engineer in Charge.
40 Providing and fixing 18 mm thick, first quality 342.00 SQMT 2003.69
black polished Granite Stone approved by the
Client/Architect, for Door and Window frames,
lintels, jambs and sills, laid in cement mortar
(1:3), including cutting, dressing, proper fixing,
making hairline joints, filling joints with white
cement/pigment/joint filler, rounding of edges,
edge polishing and finishing, with granite fixed
in single piece.
The item shall also include jamb framing
moulding, photo frame detailing, grooves,
rebates and all necessary edge profiles as per
detailed drawings, complete as directed by the
Architect/Engineer-in-Charge.
41 Providing & Fixing curved shaped urinal 12.00 NOS 6500
partition of size 900 mm (H) × 450 mm (W),
made of 8 mm thick frosted toughened glass
with polished edges, including necessary
curving as per design, complete with chrome
finished stainless steel brackets/supports,
fittings and fixtures of Jaquar or equivalent
make. The work shall include cutting, edge
finishing, fixing in proper line & level, using
suitable fasteners, gaskets and sealant, including
all materials, hardware and labour charges,
complete at all levels as directed by the
Architect/Engineer-in-Charge.
Description Qty. Unit Rate Amount
42 THREE TRACK WINDOW Providing and fixing 323.00 SQMT 9599.6
factory made UPVC glazed/wire mesh
windows/doors comprising of lead free uPVC
multi-chambered frame, sash and
mullion/coupler (where ever required)
extruded profiles having 6 mm thick High
performance glass minimum wall thickness of
1.70 mm for Series R1 and R2 profiles and
mm for Series R3 and R4 profiles conforming to
EN: 12608 in any shape, colour and design duly
reinforced with galvanized mild steel section
made of required shape & size as per CPWD
Specification, uPVC extruded glazing beads,
interlocks and Inline sash adaptor (where ever
required) of appropriate dimension, EPDM
gasket, hardware, SS 304 grade fasteners of
minimum 8 mm dia with countersunk head,
comprising of matching polyamide PA6 grade
sleeve for fixing frame to finished wall as per IS
1367 : Part 1 to 14, plastic packers, plastic caps
and necessary stainless steel screws etc. Profile
of frame, sash & mullion (if required) shall be
mitred cut and fusion welded/mechanically
jointed duly sealed at all corners, including
drilling of holes for fixing hardware and
drainage of water etc. After fixing frame the gap
adjacent finished
Exteriorwall shall
Weather 4205.00 SQMT 300
Resistant Textured wall finish made from
emusified acrylic polymers, siliceous aggregated
marble chips and quarts powder of jotun or
equivalent having average thickness of 2 mm
with approved color and textured finishes as per
company's specification and standards laid on
external rough plaster for all heights after
necessary preparatory coating incl. application
of necessary preparatory coat, scafolding, curing
44 Providing & fixing Steel work,grill work,stair 164.30 Quintal 9108.49
ladders,Entry Gate, parking shead ,etc welded in
built up/rolled steel sections framed work
including cutting, hoisting, fixing in position and
applying a priming coat of read lead paint. (A)In
beams and joists, channels angles Tees, flats,
with connecting plates or angle cleats as in main
and cross beams. Hip and jack rafters, purlins
conneted to common rafters etc completed as
directed by architect / Engineer In charge.
Description Qty. Unit Rate Amount
45 Painting two coats (excluding priming coat) on 670.00 SQMT 90.01
new steel and other metal surface with enamel
paint, brushing, interior to give an even shade
including cleaning the surface an even shade
including cleaning the surface of all dirt, dust
and other foreign matter etc. complete as
directed by Engineer Incharge.
46 Supplying and fixing stainless steel hand Railing 92.00 Rmt. 3375.7
of Grade 304 (16 gauge thick sections) with
glossy finish consisting of 32mm x 32mm size
vertical posts 900 Heigh at maximum spacing @
750 mm c/c with suitable cups at top rail of
mm x 50 mm & intermediate horiztal rails 3 nos
of 16 mm x 16 mm size etc complete at all levels
including bending to required profile. Tungsten
insert gas welding & all required accessories,
grinding & labour etc complete as per design
fixing with base slab/concrete or side wall/RCC
by hilty or equivalent fastenre and plates as per
Drawing and instruction of Engineer-in-
Charge.(work for all floors)
47 Designing, fabricating, testing, protection, 196.00 SQMT 3510.5
installing and fixing in position semi (grid)
unitized system of structural glazing (with open
joints) for linear as well as curvilinear portions
of the building for all heights and all levels,
including: (a) Structural analysis & design and
preparation of shop drawings for the specified
design loads onforming to IS 875 part III (the
system must passed the proof test at 1.5 times
design wind pressure without any failure),
including functional design of the aluminum
sections for fixing glazing panels of various
thicknesses, aluminium cleats, sleeves and splice
plates etc. gaskets, screws, toggles, nuts, bolts,
clamps etc., structural and weather silicone
sealants, flashings, fire stop (barrier)-cum-
smoke seals, microwave cured EPDM gaskets for
water tightness, pressure equalisation &
drainage and protection against fire hazard
Description Qty. Unit Rate Amount
:(b) Fabricating and supplying serrated M.S. hot
dip galvanised / Aluminium alloy of 6005 T5
brackets of required sizes, sections and profiles
etc. to accommodate 3 Dimentional movement
for achieving perfect verticality and fixing
structural glazing system rigidly to the RCC/
masonry/structural steel framework of building
structure using stainless steel anchor fasteners/
bolts, nylon seperator to prevent bimetallic
contacts with nuts and washers etc. of stainless
steel grade 316, of the required capacity and in
required numbers. (c) Providing and filling, two
part pump filled, structural silicone sealant and
one part weather silicone sealant compatible
with the structural silicone sealant of required
bite size in a clean and controlled factory / work
shop environment,
including double sided spacer tape, setting
blocks and backer rod, all of approved grade,
brand and manufacture, as per the approved
sealant design, within and all around the
perimeter for holding glass.
(d) Providing and fixing in position flashings of
solid aluminium sheet 1 mm thick and of sizes,
shapes and profiles, as required as per the site
conditions, to seal the gap between the building
structure and all its interfaces with curtain
glazing to make it watertight. (e) Making
provision for drainage of moisture/ water that
enters the curtain glazing system to make it
watertight, by incorporating principles of
pressure equalization, providing suitable gutter
profiles at bottom (if required), making
necessary holes of required sizes and of
required numbers etc. complete.This item
includes cost of all inputs of designing, labour
for fabricating and installation of aluminium
grid, installation of glazed units, T&P, scaffolding
and other incidental charges including wastages
etc., enabling temporary structures and services,
cranes or cradles etc. as described above and as
Description Qty. Unit Rate Amount
The item includes the cost of getting all the
structural and functional design including shop
drawings checked by a structural designer, dully
approved by Engineer-in-charge. The item also
includes the cost of all mock ups at site, cost of
all samples of the individual components for
testing in an approved laboratory, field tests on
the assembled working structural glazing as
specified, cleaning and protection till the
handing over of the building for occupation. In
the end, the Contractor shall provide a water
tight structural glazing having all the
performance characteristics etc. all complete as
required, as per the Architectural drawings, as
per item description, as specified, as per the
approved shop drawings and as directed by the
Engineerin- Charge.
48 Providing and supplying Spandrel Glass Panels 196.00 sqmt 2450.15
comprising of 6 mm thick heat strengthened
monolithic float glass of approved colour and
shade with reflective soft coating on surface #
of approved colour and shade so as to match the
colour and shade of the IGUs in the vision panels
etc. ,all complete for the required performances
as specified, as per the Architectural drawings,
as per the approved shop drawings, as specified,
and as directed by the Engineer- in- Charge.
Description Qty. Unit Rate Amount
49 Providing and fixing elevation feature GRC 104.00 Nos. 1250
brackets as PER ELEVATION DWG IN 30 mm
thk. for the locations as per the drawings. at all
levels made from GRC make Glass fibre
reinforced concrete (GRC) using white cement,
Quartz Sand, AR Fibres, Water Plasticizers &
COLOR in approved shape, size and length as
per the design and drawings and as per
specifications, mix design. The typical GRC
items should be of sizes as per the drawings.
Fixing of GRC items shall be with help of S.S
Screws Fixtures, M.S Angle Cleats, Fissure Plug,
and Dowel Pin proper alignment as per
drawings (Shop drawings to be submitted by
the contractor before the work start). As per
approved paint, shade & Finishing with GRC
powder & filling the joints with Epoxy sealant
neatly between GRC items and primary
structures. The fins should be in absolute
straight plumb line and length and joins
between channels should be neatly filed to make
seamless uniform surface across the entire
elevation of the building without any visibility to
50 Providing and fixing elevation feature GRC 1.00 Nos. 15000
Triangle design as PER ELEVATION DWG IN
mm thk. for the locations as per the drawings.
at all levels made from GRC make Glass fibre
reinforced concrete (GRC) using white cement,
Quartz Sand, AR Fibres, Water Plasticizers &
COLOR in approved shape, size and length as
per the design and drawings and as per
specifications, mix design. The typical GRC
items should be of sizes as per the drawings.
Fixing of GRC items shall be with help of S.S
Screws Fixtures, M.S Angle Cleats, Fissure Plug,
and Dowel Pin proper alignment as per
drawings (Shop drawings to be submitted by
the contractor before the work start). As per
approved paint, shade & Finishing with GRC
powder & filling the joints with Epoxy sealant
neatly between GRC items and primary
structures. The fins should be in absolute
straight plumb line and length and joins
between channels should be neatly filed to make
seamless uniform surface across the entire
elevation of the building without any visibility to
Description Qty. Unit Rate Amount
51 Providing and fixing elevation feature GRC 37.00 Nos. 3500
Rectangle design as PER ELEVATION DWG IN
mm thk. for the locations as per the drawings.
at all levels made from GRC make Glass fibre
reinforced concrete (GRC) using white cement,
Quartz Sand, AR Fibres, Water Plasticizers &
COLOR in approved shape, size and length as
per the design and drawings and as per
specifications, mix design. The typical GRC
items should be of sizes as per the drawings.
Fixing of GRC items shall be with help of S.S
Screws Fixtures, M.S Angle Cleats, Fissure Plug,
and Dowel Pin proper alignment as per
drawings (Shop drawings to be submitted by
the contractor before the work start). As per
approved paint, shade & Finishing with GRC
powder & filling the joints with Epoxy sealant
neatlybetween GRC items and primary
structures. The fins should be in absolute
straight plumb line and length and joins
between channels should be neatly filed to make
seamless uniform surface across the entire
elevation of the building without any visibility to
52 Providing and fixing factory made 18 mm thick 68.00 SQMT 4086.4
single extruded WPC (Wood Polymer
Composite) solid plain white colour board Jali,
CNC (Computer numeric control) routed of
approved design by Engineer-in-charge which
are machine cut for duct/shaft covering,
partitions and facades comprising of virgin
polymer of K value 58-60 (Suspension Grade),
calcium corbonate and natural fibers (wood
powder/ rice husk/wheat husk) and non toxic
additives(maximum toxicity index of 12 for
gms) having minimum density of 650 kg/cum
and screw withdrawal
strength of 1800 N (Face) minimum
compressive strength 50 N/mm2, modulus of
elasticity 850 N/mm2 and resistance to spread
of flame of Class A category with properties of
being termite/borer proof, water/ moisture
proof and fire retardant and fixing on M.S (mild
steel) frame made of 25 x 25 x 1.5 mm square
hollow box section including applying a priming
coat of approved steel primer, placed at grid
made at 1.0 x 1.0 m or as per requirement at site
with necessary stainless steel fasteners
and SS screws etc., all complete as per direction
of Engineer-In- Charge.
Description Qty. Unit Rate Amount
53 Providing, laying, spreading and compacting 220.00 Cu.mt. 2135.56
graded stone aggregate to wet mix macadam
spacification including premixing the materials
with water at OMC in mechanical mix plant
carriage of mixed materials by tipper to site,
laying in uniform layers (Layer should not be
more than 200 mm)with paver in sub base/base
course on well prepared surface and camber
with Sensor paver consolidation by vibratory
road roller to achieve the desired density by
using machine crushed chips as per required
gradation mixing with required optimum
quantity of water incl material, labour, plant
and machinary and equipment etc. complete by
plant mix method. ( Using mechanical paver ) .
54 Brick work in superstructure above plinth level 78.00 Cu.mt. 19066.1
and up to floor five level in cement mortar 1:3 (1
cement : 3 coarse sand), including centering,
scaffolding, and shuttering complete, with
common burnt clay F.P.S. (non-modular) bricks
of class designation 7.5, including brick cornices,
molded shapes, decorative profiles, necessary
grooves, cornice steps, and projections as per
approved architectural detail drawings.The
work shall include cutting, shaping, and
finishing of bricks required for cornices,
moldings, grooves, and steps, true to line, level,
and plumb. All brickwork shall be neatly
finished with uniform joints, and all cornices,
moldings, grooves, steps, and projections shall
conform to the approved architectural drawings.
55 Forming groove of uniform size from 12x12 mm 1720.00 Rmt. 100.6
and upto 25x15 mm in the top layer of washed
stone grit plastered surface as per approved
pattern, including providing and fixing
aluminum channels of appropriate size and
thickness (not less than 2 mm), nailed to the
under layer with rust proof screws and nails and
finishing the groove complete as per
specifications and direction of the Engineer-in-
Description Qty. Unit Rate Amount
56 Providing, hoisting and fixing above plinth level 4.00 Cu.mt. 18234.95
up to floor five level precast reinforced cement
concrete in mouldings as in cornices, windows
sills etc, including setting in cement mortar 1:3
(1 cement : 3 coarse sand) cost of required
centering, shuttering but, excluding the cost of
reinforcement, with 1:1.5:3 (1 cement :
coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm
nominal size derived from natural sources).
57 Providing & Fixing 6 mm thick lexan 100.00 SQMT 1441.9
Polycarbonate multi wall roofing sheet fixed
with hilti screw and rubber silicon sealer and
alluminium strip of size 50 x 3 mm etc. complete
and directed by Enginner in charge
58 Constructing of Cooking platform ( sandwich 5.00 SQMT 2955.08
type ) 80cm high resting on Kota stone / granite
stone in C.M 1:3 with providing and fixing
mm thick rough kota stone at bottom and 25mm
thick Polish kota stone/ Granite stone ( single
piece ) top and polished kota stone/ granite
stone (single piece ) 25mm thick on top with
75mm high machine cut polished Granite round
moulded facia patty including polishing etc .
complete as per drawing and specification
without stainless steel sink including necessary
cutting for sink & making hole for gas pipe and
fixing P.V.C bend of 25mm dia.
59 Sandwich Type – Kalinga over Kota :Providing & 25.00 SQMT 2925.82
fixing sandwich type washroom platform
consisting of top layer of 18 mm thick Kalinga
stone of approved shade and finish, fixed over
20 mm thick Kota stone base, forming a total
sandwich thickness of 150 mm (6 inches),
including necessary cutting, dressing, edge
polishing, moulding, and fixing in cement mortar
(1:3) with proper leveling and slope. The work
shall include backing support, filling joints with
white cement/pigment, providing necessary
grooves, rebates, and finishing edges, complete
in all respects as directed by the Engineer-in-
Description Qty. Unit Rate Amount
60 Excavation for foundation in Dense or Hard soil 11.00 Cumt. 153.41
upto 1.50m depth including sorting out and
stacking of useful materials and disposing of the
excavated stuff with all lead and lift as directed
by Engineer in charge.
61 Excavation for foundation in Dense or Hard soil 8.00 Cumt. 166.44
from 1.50 m. to 3.00 m. depth including sorting
out and stacking of useful materials and
disposing of the excavated stuff with all lead and
lift as directed by Engineer in charge.
62 P/L PCC 1:3:6 (1-cement : 3 coarse sand : 6 M/c 0.20 Cumt. 3231.78
stone aggregate 20 / 40mm nominal size) in
foundation concrete / floor concrete incl.
machine mixing, ramming, consolidation &
curing etc. incl. cost of form work if required etc.
complete at all levels.
63 Brickwork using common burnt clay building 4.00 Cumt. 4121.55
bricks having crushing strength not less than
Kg./Sq. Cm. in foundation and plinth in cement
Mortar 1:6 (1-Cement : 6 - fine sand).
Conventional in Foundation & Plinth (Upto
64 Providing 15mm thick cement plaster in single 27.00 Sq. mt. 171.21
coat on brick/concrete walls for interior
plastering upto floor two level and finished even
and smooth in (i) Cement mortar 1:4 (1-cement:
65 Supplying and laying of screened rounded gravel 3.00 Cumt. 247.85
of 25 to 90 mm, 20 to 50 mm and 5 to 20 mm
size filling in layers or packing around stainer
pipe etc. complete.
66 Drilling of Pilot Bore hole in alluvial strata by 220.00 R.mt 972.63
direct rotary rig of 250 to 300 mm dia. for a
depth of 110 meters.
67 Providing and fixing to wall ceiling and floor
Kg. F/Cm2 working pressure poluthene pipes of
the following outside Dia. Low densidy,
complete with special falnge compression type
fittings, wall clipsetc. including making good the
wall ceiling and floor.
68 Providing and fixing to wall ceiling and floor -
10.0 Kg. F/Cm2 working pressure poluthene
pipes of the following outside Dia. Low densidy,
complete with special falnge compression type
fittings, wall clipsetc. including making good the
wall ceiling and floor.
Description Qty. Unit Rate Amount
69 Providing and fixing in position cowel went to -
70 Providing and fixing screw down bib taps of 3.00 Each 186.83
following size.(B) Brass chromium plated
screws down Bib Tap. (15 mm)
71 Providing and fixing Gun metal check or non- -
return fullway wheel valve.
(A) 15 mm dia 2.00 Each 186.83
(B) 25 mm dia 17.00 Each 420.63
(C) 32 mm dia 7.00 Each 314.73
(D) 40 mm dia 7.00 Each 663.43
72 Providing and fixing ball cock of approved. 5.00 Each 137.89
quality as directed.(B) Abonite 50 mm
73 Providing laying and jointing in true line and -
level U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the
help of clamp at every two metre C/C or shall be
concealed as directed including necessary
fittings etc. including testing of pipe and joints
and fixing the same with adhesive
(A) 15 mm dia 65 Rmt 72.65
(B) 25 mm dia 210 Rmt 91.84
(C) 40 mm dia 50 Rmt 148.12
(D) 50 mm dia 110 Rmt 195.67
74 Providing, laying and jointing in true line and -
level U.P.V.C (Type B) conforming to IS 13592-
1992 with one end plain and other end socketed
with rubber ring, & fittings conforming to ISI
14735-1999 of approved make for drainage
system pipe line, pipe shall be jointed with each
other with rubber lubricant, pipe shall be fixed
on wall using of PVC clamp at every 2000 mm
center to center or shall be concealed in walls as
directed including necessary fittings such as
bends, shoes etc. including testing of pipes and
joints and jointed with adhesive solvent cement
including cost of all materials.
(A) 110 mm dia (110mm diametre x 149mm 385 Rmt 856.03
length x 145mm height)
(B) 160 mm dia (160mm diametre x 210mm 10 Rmt 834.38
length x 196mm height)
Description Qty. Unit Rate Amount
75 Providing and fixing PVC SWR Nahni trap IS 3 each 585.37
14735 for drain - 100 mm diameter with jali of
the following nominal diameter of self cleansing
design with C.I scread down or hinged grating
including the cost of cutting and making good
76 Providing erecting and fixing double coated ISI 25000 litre 3.95
water tank of required capacity each with all
necessary fittings and connection etc. complete
77 Providing and fixing S.W. gully trap with C.I. 7 Each 1292.19
grating brick masonry chamber and water tight
C.I. cover with frame of 300mm x 300mm size
(inside) with standard weight.(i) Square mouth
traps. (A) 100mm x 100mm size P type.
78 Providing laying (to level or slopes) and jointing 70 Rmt 254.89
reinforced concrete Light duty non-pressure
pipes I.S. class NP2 of the following internal
diameter with collars and butt ends prepared for
collar joints including testing of joints
complete.(B) 150mm
79 Constructing Manhole with R.C.C. top slab in 25 Each 11042.74
1:2:4 mix (1- cement :2-coarse sand : 4-graded
stone aggregate 20mm nominal size)
foundation concrete 1:3:6 mix (1-cement : 3-
coarse sand :6-Brick bats 40 + 50mm size)
inside plastering 15mm thick with Cement
Mortar 1:3 (1- Cement : 3-coarse sand) finished
with a floating coat of neat cement and making
channels in cement concrete 1:2:4 mix (1
Cement :2-Coarse sand :4-stone aggregate
20mm nominal size) finished smooth complete
including curing and festing (i) Inside size
900mm x 1200mm and 1.5M. deep including C.I.
cover with frame size 560mm diameter total
weight of cover and frame to be not less than
128 kgs. (Wt. of cover 64 Kg. and Wt. of frame
Kg.)(A) With 230mm thick walls of brick msonry
using brick having crushing strength not less
than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1-
Cement: 5-Coarse sand) (1) A type depth
Metre for 150mm diameter sewer.
80 (I) Extra rate for constructing B.B. masonry for 25 Each 522.96
every additional depth of 0.1M. or Part thereof
over item No.24.27 (I) for depth from 0.9M to
Description Qty. Unit Rate Amount
81 Constructing Manhole with R.C.C. top slab in 20 Each 19349.63
1:2:4 mix (1- cement :2-coarse sand : 4-graded
stone aggregate 20mm nominal size)
foundation concrete 1:3:6 mix (1-cement : 3-
coarse sand :6-Brick bats 40 + 50mm size)
inside plastering 15mm thick with Cement
Mortar 1:3 (1- Cement : 3-coarse sand) finished
with a floating coat of neat cement and making
channels in cement concrete 1:2:4 mix (1
Cement :2-Coarse sand :4-stone aggregate
20mm nominal size) finished smooth complete
including curing and festing (i) Inside size
900mm x 1200mm and 1.5M. deep including C.I.
cover with frame size 560mm diameter total
weight of cover and frame to be not less than
128 kgs. (Wt. of cover 64 Kg. and Wt. of frame
Kg.)(A) With 230mm thick walls of brick msonry
using brick having crushing strength not less
than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1-
Cement: 5-Coarse sand) (2) B type depth
Metre for 150mm diameter sewer.
(II) Extra rate for constructing B.B. masonry for 20 Each 397.19
every additional depth of 0.1M. GR Part thereof
over item No.24.27 (I) for depth from 1.50M. to
82 Providing and fixing cast iron steps of size 500 Each 207.66
500mm x 150mm x 22.5mm and painting with
two coats of Anti corrosive paint etc. complete.
83 Constructing brick masonry chamber for 25 Each 2932.93
underground C.I. Inspection chamber and bends
with bricks having crushing strength not less
than 35Kg/Cm2 in C.M. 1:5 C.I. cover with frame
(Light duty) 455mm x 610mm intenal
dimensions total weight of cover with frame to
be not less than 38Kg. (Wt. of cover 23 Kg.) and
Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4
mix (1 cement :2- coarse sand :4-graded stone
aggregate 20mm size) foundation concrete
1:5:10 inside plaster 15mm thick with cement
mortar 1:3 finished smooth with a floating coat
of neat cement on walls and bed concrete etc.
complete.(i) Inside dimensions 455mmx 610mm
and 450mm deep for single pipe line.
Extra over items 24.44 for every additional 25 Each 242.39
depth of 0.1M. of part thereof beyond 450mm
depth for Brick masonry chamber.(i) for 455mm
Description Qty. Unit Rate Amount
84 Constructing brick masonry chamber for 25 Each 3660.76
underground C.I. Inspection chamber and bends
with bricks having crushing strength not less
than 35Kg/Cm2 in C.M. 1:5 C.I. cover with frame
(Light duty) 455mm x 610mm intenal
dimensions total weight of cover with frame to
be not less than 38Kg. (Wt. of cover 23 Kg.) and
Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4
mix (1-cement :2- coarse sand :4-graded stone
aggregate 20mm size) foundation concrete
1:5:10 inside plaster 15mm thick with cement
mortar 1:3 finished smooth with a floating coat
of neat cement on walls and bed concrete etc.
complete.(ii) Inside dimensions 500mm x
mm and 450mm deep for pipe line with one or
Extra over items 24.44 for every additional 25 Each 264.86
depth of 0.1M. of part thereof beyond 450mm
depth for Brick masonry chamber.(ii) for
500mm x 700mm size.
85 Constructing brick masonry chamber for 30 Each 7180.44
underground C.I. Inspection chamber and bends
with bricks having crushing strength not less
than 35Kg/ Cm2 in C.M. 1:5 C.I. cover with frame
(Light duty) 455mm x 610mm intenal
dimensions total weight of cover with frame to
be not less than 38Kg. (Wt. of cover 23 Kg.) and
Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4
mix (1 cement :2- coarse sand :4-graded stone
aggregate 20mm size) foundation concrete
1:5:10 inside plaster 15mm thick with cement
mortar 1:3 finished smooth with a floating coat
of neat cement on walls and bed concrete etc.
complete.(iii) Inside dimensions 600mm x
mm and 450mm deep for pipe lines with three
or more inlets.
Extra over items 24.44 for every additional 30 Each 325.59
depth of 0.1M. of part thereof beyond 450mm
depth for Brick masonry chamber.(iii) for
600mm x 850mm size.
86 Providing and fixing on platform stainless steel 3 Each 2868.88
Sink glossy ASIS 304 grade x 1mm thick with
over all size 610x460mm & bowl size
560x410x200mm & SS Pillar cock with
extention body including fixing the sink in
platform & making good the same including the
cost of PVC waste pipe of 32mm dia. and PVC
waste coupline etc complete as directed by EIC.
Description Qty. Unit Rate Amount
87 Providing and fixing Two way BIB cock with 27 Each 2661.35
wall flange of genuine Jaquar ompany brand, in
with model no FUS-CHR29041, water tap brand
or approved ISI brand quality, fixing in pieline
and testing the same… etc., complete., as
directed by EIC
88 Providing and fixing wash down water closet 27 Each 18705.33
European type WC pan (Wall Hung) like JAQUAR
CNS-WHT-961SPP- SIZE 365x545x360MM and
P trap distance 23.5 cms with integral P trap
including jointing the trap with soil pipe in
cement mortar 1:1 (1 cement : 1 find sand)
including providing and fixing of 1) Health
Faucet hand shower heavy duty with SS braided
hose 1.2 MT long pipe to water closet - JAQUAR
ALD-CHR-573 with Single Piece Slim Concealed
Cistern Body with Installations Kit & “S-Type”
drain pipe connection set for Wall Hung WC
(without Flush Control Plate) - JCS-WHT-2400S
with Control Plate Opal - JCP-CHR-152415,Toilet
roll holder etc,complete
89 Providing and fixing Wash Basin vitreous china 27 Each 8080.39
table top wash basin size 560mm x 450 mm in
colour selected by engineer-in-charge with
single hole for pillar tape with CP or MS brackets
painted white including cutting holes and
making good the same including (1) Providing
and fixing SS waste coupling of 32 mm dia size
half theread with 80mm height for wash basin
with rubber plug (2) Providing and fixing SS
bottle trap with internal partition of 32mm size
with 250mm &190mm long wall flange
connection pipes and wall flange of approved
quality with necessary fitting for wash basin (3)
Providing and fixing SS Pillar cock with
extention body like JAQUAR FUS-CHR-29021N
with necessary fittings etc. complete (4)
Providing and fixing SS finish Angular Stop Cock
quarter turn like Jaquar code FUS-29053 with
necessary fittings (5) Providing and fixing SS
finish soap dispenser with metallic bottle ,Towel
ring etc. complete
Description Qty. Unit Rate Amount
90 Providing and fixing Urinal of approved quality 12 Each 20874.68
including connection with trap and with integral
longitudinal flush pipe.(A) Squating plate
pattern white earthenware size of urinal
370mm x 315x 620 mm.of jaquar make code no
URS -WHT-132530 including (1) Providing and
fixing SS finish waste coupling of 32 mm dia size
half theread with 80mm height like jauar -ALD -
709 for wash basin with rubber plug (2)
Providing and fixing SS finish bottle trap with
internal partition of 32mm size with 250mm
&190mm long wall flange connection pipes and
wall flange like jaquar ALD-769 of approved
quality with necessary fitting for wash basin (3)
Sensotronic Concealed Type Flushing Valve
Faucets of auto closing system for urinal like
jaquar SNR-STL-51087 of approved quality and
connection with waste pipe trap etc. complete
91 Providing and fixing PVC SWR pipes IS 13592 10 Rmt. 336.33
for Drain - 75 mmdia
92 Providing and fixing PVC SWR P- Trap IS 14735 41 No. 311.08
for Drain -110x110
93 Providing and fixing Gun metal check or non- 10 No. 757.50
return fullway wheel valve. (A) 50mm dia.
94 Providing laying and jointing PVC SWR pipes IS 130 Rmt. 292.90
13592 for Drain - 50 mmdia it's accessories.
95 Providing and fixing to the inlet mouth of rain 10 No. 452.48
water pipe cast iron grating 15 cm diameter and
weighing not less than 440 grams.
96 Providing and fixing Handicap wash down 3 Each 19719.61
water closet European type WC pan (Wall Hung)
like JAQUAR CNS-WHT-961SPP- SIZE
365x545x360MM and P trap distance 23.5 cms
with integral P trap including jointing the trap
with soil pipe in cement mortar 1:1 (1 cement :
find sand) including providing and fixing of 1)
Health Faucet hand shower heavy duty with SS
braided hose 1.2 MT long pipe to water closet -
JAQUAR ALD-CHR-573 with Single Piece Slim
Concealed Cistern Body with Installations Kit &
“S-Type” drain pipe connection set for Wall
Hung WC (without Flush Control Plate) - JCS-
WHT-2400S with Control Plate Opal - JCP-CHR-
152415,Toilet roll holder including grab bar
Description Qty. Unit Rate Amount
97 Providing and laying in trench including UPVC 320 Each 1186.75
Foamcore PVC pipe of SN8 grade 10KG with all
jointing, fittings, etc. complete with testing. The
above pipe includes excavation, refilling, CC
1:5:10 bedding, encasing etc. all civil work
required to lay the pipe as per site soil condition.
The scope shall also include connection to the
existing network with required material & civil
98 Excavation for foundation in Loose or Soft soil 212.00 Cumt. 120.01
upto 1.50m depth including sorting out and
stacking of useful materials and disposing of the
excavated stuff with all lead and lift as directed
by Engineer in charge.
99 Excavation for foundation in Loose or Soft soil 212.00 Cumt. 133.05
from 1.50 m. to 3.00 m. depth including sorting
out and stacking of useful materials and
disposing of the excavated stuff with all lead and
lift as directed by Engineer in charge.
100 Excavation for foundation in Loose or Soft soil 120.00 Cumt. 146.09
from 3.00 m. to 5.00 m. depth including sorting
out and stacking of useful materials and
disposing of the excavated stuff with all lead and
lift as directed by Engineer in charge.
101 Filling available excavated earth in trenches. 290.00 Cumt. 133.66
plinth, sides of foundations etc. in layers not
exceeding 20cm. In depth consolidating each
disposited layer by ramming and watering etc.
complete as directed by Engineer in charge.
102 Providing and laying Rubble soling with sand in 36.00 Cumt. 1464.60
foundation below PCC and watering and
compacting the same etc. completed..
103 Providing and laying PCC 1:3:6 (1-cement : 3 30.00 Cumt. 3231.78
coarse sand : 6 M/c stone aggregate 20 / 40mm
nominal size) in foundation concrete / floor
concrete incl. machine mixing, ramming,
consolidation & curing etc. incl. cost of form
work if required etc. complete at all levels as
directed by Engineer in charge.
Description Qty. Unit Rate Amount
104 Providing and laying controlled cement concrete 42.00 Cumt. 4493.55
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete at all levels
for RCC FOOTING
105 Providing and laying controlled cement concrete 36.00 Cumt. 7282.35
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete COLUMN UP
TO GROUND FLOOR LEVEL & FIRST FLOOR
106 Providing and laying controlled cement concrete 36.00 Cumt. 6591.15
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc.complete FOR RCC
BEAM at Compound wall
107 Providing and laying controlled cement concrete 16.00 Cumt. 7587.91
M-250 for RCC work as per detailed drawings
including centering, shuttering (Only Fresh Ply),
machine mixing, vibrating, scaffolding, curing,
centering having double or more height
wherever required & finishing etc. but excluding
cost of reinforcement etc. complete at all levels
for RCC SILL & COPING
108 Providing TMT Bar FE 500D reinforcement for 22770.00 Kg. 77.29
R.C.C. work including bending, binding and
placing in position complete.
109 Brickwork using common burnt clay building 150.00 Cumt. 4403.40
bricks having crushing strength not less than
Kg./Sq. Cm. in foundation and plinth in cement
Mortar 1:6 (1-Cement : 6 - fine sand). Compound
Wall (Upto 10 ton).
Description Qty. Unit Rate Amount
110 20mm thick sand faced cement plaster on walls 1380.00 Sq. mt. 337.53
upto height 10 metres above ground level
consisting of 12mm thick backing coat of C.M.
1:3 (1-cement : 3-sand) and 8mm thick finishing
coat of C.M. 1:1 (1-cement : 1-sand) etc.
111 Finishing wall with weather proof exterior 1380.00 Sq. mt. 117.41
emulsion paint on wall surface (two coats) to
give an required shape even shade after
thoroughly brushing the surface to remove all
dirt, and remains of loose powdered
materials.etc complete
112 Providing & fixing Steel work,Entry Gate, 288.30 Quintal 9108.49
parking shead ,etc welded in built up/rolled
steel sections framed work including cutting,
hoisting, fixing in position and applying a
priming coat of read lead paint. (A)In beams and
joists, channels angles Tees, flats, with
connecting plates or angle cleats as in main and
cross beams. Hip and jack rafters, purlins
conneted to common rafters etc completed as
directed by architect / Engineer In charge.
113 Painting two coats (Including priming coat) on 710.00 Sq. mt. 125.88
new steel and other metal surface with enamel
paint, brushing, interior to give an even shade
including cleaning the surface an even shade
including cleaning the surface of all dirt, dust
and other foreign matter etc. complete as
directed by Engineer Incharge.
114 Providing & Fixing 6 mm thick lexan 470.00 Sq. mt. 1441.90
Polycarbonate multi wall roofing sheet fixed
with hilti screw and rubber silicon sealer and
alluminium strip of size 50 x 3 mm etc. complete
and directed by Enginner in charge
Description Qty. Unit Rate Amount
115 Providing and Fixing 'U' Shaped Barbed wire 310.00 Rmt 734.25
fencing on Existing compound wall top with
verical angle of 50x50x6 mmx0.45 Mtr height,
two cross angles 50x50x6 mm x 0.40 Mtr.
Length, , two vertivcal angle 50x50x6 mm x
Mtrhaving 1 Horizontal rows , 2 horizontal rows
at each side of cross angles ,and 2 horizontal
rows at each side of verical angle and
horizontal rows at top side of barbed wire.and
@ 0.10m c/c Spiral turns in each 27 mtr in
length each 3.00m span and 750 mm effective
dia, horizontal and two diagonal barbed wire
rows on each cross angles incl. cost of barbed
wires, necessary GI stapplings, fixing in C.C.
(1:2:4) blocks of 0.35x0.35x0.30 Mtr. size on top
of compound wall, painting angles with one coat
of anticorrossive primer and two coats of
enamel paint of approved quality, necessary
scaffolding etc. complete as per the direction of
the Engineer in Charge.
116 Point wiring for Light / Bell with 2-1.5 sq.mm 407.00 Pt. 485.81
& earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in
below type of pipe erected with 6A Modular
type switch / bell push & accessories and earth
continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base
frame covered with textured/metallic/white
front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary Lamp
holder/ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
complete cat III
Description Qty. Unit Rate Amount
117 Point wiring for Tissino / Modular secondary 319.00 Pt. 167.66
light point with 2-1.5 sq.mm & earth wire of
1.5 sq.mm (green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper
wires, in below type of pipe to be erected
complete with earth continuity and necessary
connection with primary light with
accessories erected on Metal / PVC /
wooden box covered with 3 mm
thick PC(Polycarbonate) / Acrylic sheet for
open / concealed wiring. with necessary
Lamp holder / ceiling rose / H.D.Connector as
Note:- Maximum up to 6 mtrs length, excess will
be considered as Mains for Secondary Point.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
complete cat III
118 Point wiring for FAN with 2-1.5 sq.mm & earth 90.00 Pt. 674.68
wire of 1.5 sq.mm (Green) both are of .ISI
marked 1.1 KV Grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length, in
below type of pipe erected with 6A Modular
type switch and hum free EME step type
electronic fan regulator mounted and
accessories with earth continuity of following
type erected on PVC / Metallic/Wooden box,
single mounting base frame covered
with textured/metallic/white front plate
modules erected on / in wall / ceiling as per
pipe erected. with necessary ceiling rose /
H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
complete cat III
Description Qty. Unit Rate Amount
119 Point wiring for Two Way Controlled Light Point 15.00 Pt. 603.98
with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(green) both are of .ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper wires
erected in below type of pipe with 6A Modular
type switches and following type of accessories
erected on PVC / Metallic/Wooden box, single
mounting base frame covered with textured /
metallic/white front plate modules erected on /
in wall / ceiling as per pipe erected. with
necessary batten/angle holder or ceiling rose or
H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
complete CAT III
120 Point wiring for Individual Plug with & earth 15.00 Pt. 745.38
wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length, in
below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on
PVC / Metallic/Wooden box covered with
appropriate front plate modules erected on / in
wall / ceiling as per pipe erected with following
type of accessories [II] For 16A Plug and
amp switch with 2-2.5 sq.mm Cu. Wire from
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
complete cat III
121 Point wiring for Individual Plug with & earth 80.00 Pt. 510.05
1.5 sq.mm (Green) both are of ISI marked
1.1 KV grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below
type of pipe erected complete with Modular
type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with
appropriate front plate modules erected on
/ in wall / ceiling as per pipe erected with
following type of accessories. [I] For 6A Plug and
6 a switch with 2-1.5 sq.mm Cu. Wire from
nearby switchboard/mcb db board (f) with
medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete
Description Qty. Unit Rate Amount
122 Point wiring for on board Looped Plug with 6A 120.00 Pt. 257.55
Modular type switch & 5 pin socket erected on
PVC / Metallic/Wooden box, single mounting
base frame covered with textured /
metallic/white front plate modules erected on
/ in wall / ceiling with following type
accessories Cat. III
123 Providing & erecting Switch board for 66.00 Ea 1133.22
Computer or electric apparatus consisting of
following modular type accessories mounted
with PVC / Metallic concealed/open box
with single mounting base frame covered
with textured/metallic /white front
plate,modules erected with necessary
connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A 5 pin Plug
For Modular Type Accessories Cat. III
124 Providing following type of Modular 66.00 Ea 160.59
Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base
frame covered with textured /
metallic/white front plate , modules erected
with necessary connections as per site
situation directed by Engineer In charge.
(8) Computer RJ-45 socket Cat.III
125 SITC of CAT6 UTP 24AWG PATCH 66.00 Ea 155
CORD:1M,Plug 30U' Snag less
[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
126 SITC of CAT6 UTP 24AWG PATCH 66.00 Ea 199
CORD:2M,Plug 30U' Snag less
[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
127 Supplying & erecting approved make Dual band 20.00 Ea. 1978
128 Supplying & erecting approved make LAN cable 6500.00 Mtr. 47.47
of following size in pipe as per direction CAT -
129 Supplying & erecting access point with POE. 2.00 Ea. 16230.7
Note : 3 Nos. of Access Point already available in
Description Qty. Unit Rate Amount
130 Providing following type of Modular 66.00 Ea 160.59
Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base
frame covered with textured /
metallic/white front plate , modules erected
with necessary connections as per site
situation directed by Engineer In charge.
(3) Two Pin/RJ-11 Telephone Socket
[A] For One Gang Cat.III
131 Supplying & erecting approved make 1320.00 Mtr. 20.2
Telephone Cable electrolytic copper conductor
PE insulation twisted in two pairs, &
wrapped with FRLS PVC tape & sheathed
with FRLS PVC or HFFR outer Jacket suitable
for telephone wiring & confirming to C-DOT
erected in existing pipe. of following size of
conductors & nos.of pairs. With
necessary connections.
[A] Conductor Size 0.5 mm
132 Providing & erecting main Distribution (MDF) 3.00 Ea. 1747.3
type, back mounted frame as per DoT
standard approved with krone strips
(c) Suitable for 50 pair
Description Qty. Unit Rate Amount
133 SITC of Digital / PCM / TDM EPABX System 1.00 Ea. 109743.57
having SMT design, system with flexible
universal slots. Inbuilt Auto attendant facility,
Minimum 15 Nos. conference, Analog extension
line, Calling GSM, E&M line, PRI / EI & VOIP
program me through Analog telephone digital
key from Ethernet, public address cord, shall
have unrestricted simultaneous dialing facility,
QSIG protocol on PRI, 95 / STD / ISD / Local-
Locking, Class of Service, Quick Dial-Single Digit
dialing of any two external number, Once only
ring device, Chairman / Secretary - Do not
disturb Facility, Power Down Mode, Hot Line,
Hot Outward Dialing, Day Night Mode, Auto Call
Back, Barge-in, Call Pick Up & Call Transfer, Call
transfer while Ringing with Voice Guide System,
(DISA), Caller ID (CLI), CLI Base ECF, CLI Base
routing Internet Ready Port, External Music
Port, Call Budgeting, Call Most Calculation
(ASMDR), DID Direct Inverse Dialing, External
Music Input, Fax Homing, Global Directory
Printing with following capacities [[Approved by
Competent Authority i.e. not Below the rank of
Executive Engineer ]
[D] No of Extension 64, No of Junctions 12,
Port IP Resource in-built, 4 Port Web base Video
Conferencing,&Noerecting
134 Supplying of expandable
pushports : 240, type
button 66.00 Ea. 565.6
telephone instrument having speaker phone
Caller ID & hands free dialing system &
memories with display system Single line
[[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
135 Providing following type of Modular 2.00 Ea 160.59
Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base
frame covered with textured /
metallic/white front plate , modules erected
with necessary connections as per site
situation directed by Engineer In charge.
(4) TV Co-axial Socket outlet Cat.III
136 Providing & Erecting approved make following 100.00 Mtr. 39.39
size of TV Co-axial flexible cable comprising
inner conductor of solid bare copper insulated
with Foam PE & Secondary conductor made
of poly - Aluminium film bonded Al.
Braids @ suitable coverage overall
sheathed with black PVC
Description Qty. Unit Rate Amount
137 providing and erecting Mains with ISI marked, 30.00 Mtr. 91.91
1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC -
erected in existing pipe of following size
(Specifically for control panel, relays, power
switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts
if required.One wire 10.00 sq. mm
138 providing and erecting Mains with ISI marked, 30.00 Mtr. 142.41
1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC -
erected in existing pipe of following size
(Specifically for control panel, relays, power
switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts
if required.One wire 16.00 sq. mm
139 providing and erecting Mains with ISI marked, 30.00 Mtr. 236.34
1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC -
erected in existing pipe of following size
(Specifically for control panel, relays, power
switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts
if required.One wire 25.00 sq. mm
140 providing and erecting Mains with ISI marked, 30.00 Mtr. 300.98
1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC -
erected in existing pipe of following size
(Specifically for control panel, relays, power
switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts
if required.One wire 35.00 sq. mm
141 Providing and erecting Mains with 1.1 KV 1600.00 Mtr. 62.62
grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following
type of pipe to be erected concealed in
/flushed on wall/ceiling, with
1.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth
following size.
(A) With medium class Rigid PVC pipe
and accessories
(a) 2 wire 1.5 sq. mm
Description Qty. Unit Rate Amount
142 Providing and erecting Mains with 1.1 KV 2300.00 Mtr. 82.82
grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following
type of pipe to be erected concealed in
/flushed on wall/ceiling, with
1.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth
following size.
(A) With medium class Rigid PVC pipe
and accessories
(b) 2 wire 2.5 sq. mm
143 providing and erecting Mains with 1.1 KV grade 300.00 Mtr. 112.11
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected in / on wall / ceiling with 2.5 sq. mm
copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of
(A) with medium class Rigid PVC pipe and
accessories (a) 2 wire 4 sq. mm
144 Providing and erecting ISI mark Medium 5620.00 Mtr. 33.33
class RIGID PVC PIPES of following size
complete to be erected on/in wall or ceiling
erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & Clamps
with following dia of pipes, in
approved manner as directed
145 Providing & erecting PVC Corrugated 500.00 Mtr. 21.21
Flexible Conduit with required nos. of
coupling, PVC bushes, Check-nuts etc.
complete of following
sizes.(2) 25 mm
146 Providing and erecting Sheet Steel powder 3.00 Ea 885.77
coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link,
earth bar and DIN rail, Conforms to IS 8623-
1 & 3, IEC 61439-1 & 3 without MCB to
house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to
(A) single phase incoming and horizontal single
(b) sheet steel double door (IP-43)
Description Qty. Unit Rate Amount
147 Providing and erecting Sheet Steel powder 6.00 Ea 1152.41
coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link,
earth bar and DIN rail, Conforms to IS 8623-
1 & 3, IEC 61439-1 & 3 without MCB to
house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to
(A) single phase incoming and horizontal single
(b) sheet steel double door (IP-43)
148 Providing and erecting Sheet Steel powder 3.00 Ea 1492.78
coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link,
earth bar and DIN rail, Conforms to IS 8623-
1 & 3, IEC 61439-1 & 3 without MCB to
house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to
(A) single phase incoming and horizontal single
(b) sheet steel double door (IP-43)
149 Providing and erecting Sheet Steel powder 6.00 Ea 2913.85
coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link,
earth bar and DIN rail, Conforms to IS 8623-
1 & 3, IEC 61439-1 & 3 without MCB to
house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to
(B) three phase incoming and single phase
horizontal type outgoing Per phase isolation
(b) sheet steel double door
150 providing and erecting Miniature circuit breaker 150.00 Ea 112.11
single pole 6A to 25A suitable to operate on
240 V A.C. system and having breaking
capacity 10 KA to be erected in existing box.
confirming to IS 8828/1996 with ISI Mark Cat.III
Description Qty. Unit Rate Amount
151 Providing & erecting 240 V MCB double pole 12.00 Ea. 278.76
switch for lighting Load (B Curve) having 10 KA
breaking capacity & confirms to IS : 8828 in
existing box having following capacity
(A) 6 to 32 Amp. Cat-III
152 Providing & erecting 240 V MCB double pole 10.00 Ea. 295.93
switch for lighting Load (B Curve) having 10 KA
breaking capacity & confirms to IS : 8828 in
existing box having following capacity
(B) 40 Amp. Cat-III
153 Providing & erecting 415 V MCB Four Pole for 15.00 Ea. 595.9
Motor & Inductive Load (C Curve) having 10KA
breaking capacity & confirms to IS :8828 in
existing box having following capacity
(a) 6 to 32 Amp. Cat.III
154 Providing & erecting 415 V MCB Four Pole for 5.00 Ea. 668.62
Motor & Inductive Load (C Curve) having 10KA
breaking capacity & confirms to IS :8828 in
existing box having following capacity
(b)40 Amp. Cat.III
155 providing and erecting Approved make RCCBs 30.00 Ea 1969.5
conforming to IS: 12640 and having sensitivity
of 30 mA and Short Circuit withstand
capacity of 10 KA and suitable for operation
on single phase 240 V,50Hz. having
characteristic of quick action & tripping with all
advance feature & do not incorporate any
electronic component. for following Max. rating
erected as directed
(i)25Amps. DP Cat. III
156 providing and erecting Approved make RCCBs 12.00 Ea 2235.13
conforming to IS: 12640 and having sensitivity
of 30 mA and Short Circuit withstand
capacity of 10 KA and suitable for operation
on single phase 240 V,50Hz. having
characteristic of quick action & tripping with all
advance feature & do not incorporate any
electronic component. for following Max. rating
erected as directed
(ii) 40Amps. DP Cat. III
Description Qty. Unit Rate Amount
157 Supplying and erecting triple pole & neutral 12.00 Ea 1961.42
440V / 500V panel mounting Copper Busbars
with four equal Nos. of electrolyte bus having
current density not more than 1.6 Amp. / sq.mm
(Rated current / cross section area) duly
wrapped with colour insulating tape for phase
sequence of following current carrying capacity,
erected with necessary bus bar supports
/insulators, main cable socket to each bar,
erected in existing cubical panel with necessary
connections. (A) Suitable for 100 Amp. Capacity
158 Supplying and erecting triple pole & neutral 3.00 Ea 3202.71
440V / 500V panel mounting Copper Busbars
with four equal Nos. of electrolyte bus having
current density not more than 1.6 Amp. / sq.mm
(Rated current / cross section area) duly
wrapped with colour insulating tape for phase
sequence of following current carrying capacity,
erected with necessary bus bar supports
/insulators, main cable socket to each bar,
erected in existing cubical panel with necessary
connections. (B) Suitable for 200 Amp. capacity
159 Supplying and erecting triple pole & neutral 5.00 Ea 4909.61
440V / 500V panel mounting Copper Busbars
with four equal Nos. of electrolyte bus having
current density not more than 1.6 Amp. / sq.mm
(Rated current / cross section area) duly
wrapped with colour insulating tape for phase
sequence of following current carrying capacity,
erected with necessary bus bar supports
/insulators, main cable socket to each bar,
erected in existing cubical panel with necessary
connections. (C) Suitable for 300 Amp. capacity
160 Providing and erecting Approved make Four 16.00 Ea 6173.12
pole moulded case circuit breaker having
breaking capacity ICU of 25 KA. at 415 V,having
normal current rating up to 25 A to 100A. with
Fixed thermal & magnetic release suitable to
work on A.C. supply 50 c/s. with all internal
connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing. Cat III
Description Qty. Unit Rate Amount
161 Providing and erecting Approved make Four 2.00 Ea 8055.76
pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. at 415 V. having
normal current rating 125A. with Fixed thermal
& magnetic release suitable to work on
A.C.supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in
existing 16 G.M.S. housing. Cat III
162 Providing and erecting Approved make Four 2.00 Ea 20946.39
pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. and above at
415 V . having normal current rating 250A.
with variable thermal & magnetic release
suitable to work on A.C.supply 50 c/s. with all
internal connections, spreader tinned copper &
complete erected in existing 16 G.M.S. housing.
163 Providing and erecting Approved make Four 2.00 Ea 25228.79
pole moulded case circuit breaker having
breaking capacity ICU of 50 KA and above at
415 V having Normal current rating 400A. with
variable Thermal & magnetic release suitable to
work on A.C.supply 50 c/s. With all internal
connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing.
164 Supplying & erecting approved make Four Pole 1.00 Ea 22255.35
415V change over switch interior for panel
mounting with operating mechanism A.C.23
duty confirming to IS for (F)400A cat III
Description Qty. Unit Rate Amount
165 Providing & erecting weather proof, dust 10.00 Sq. Mtr. 14902.55
& vermin proof, floor mounted front
operated indoor type cubical panel board
necessary IP- 42 and above protection as per
approval from engineer incharge made from
14 SWG thick CRC M.S. sheet for outer body
& doors, 16 SWG thick CRC M.S.sheet for
internal partitions with necessary
accesories , supporting angles/ flats
channel including cutting, bending, drilling,
welding, riveting with internal partitions &
cable alley as per requirements &
instruction of engineer-in- charge with
erection of supplied switch gears, BUSBARS,
suitable size of inter connecting PVC copper
wire / copper-aluminium strips, rubber
grommets, rib, bakelite control fuses/MCB
for measuring instruments, earth bus & earth
bolts, foundation flange - bolts-base Plates,
sufficient nos. of hinged doors, handles
with locking arrangement and rubber
gasket,heavy duty end terminal
connection,danger notice board,necessary
ventilation,earthing strip complete. The
Panel shall be painted with epoxy powder
coating (The rates excludes the cost of
166 (ii) with 550 bus
Depthinter connecting mains 4.00 Sq. Mtr. 19387.96
167 Providing , erecting , fabricating the M.S. 210.00 Kg. 77.77
structure as per requirement on site
incorporating proper size of M.S.
angles,square,round, flats, bars, channels,
sections complete with cutting, welding,
grinding & finishing duly painted with one
coat of red oxide with erection on site as
per direction of engineer in charge with
necessary grouting, cementing, plastering &
Description Qty. Unit Rate Amount
168 Providing and erecting multifunctional meter 6.00 Ea 14123.84
suitable for application of Power monitoring and
showing measurement of following Voltage,
Frequency, Apparent energy, Apparent power,
Active and reactive energy, Active and reactive
power, Average voltage Vavg, Peak demand
power PM, QM, SM, Demand power P, Q, S,
Apparent power S, S1, S2, S3, Unbalance current,
Power factor and displacement PF (signed, four
quadrant), Calculated neutral current, Active,
reactive, apparent energy (signed, four
quadrant), Active power P, P1, P2, P3, Voltage
U21, U32, U13, V1, V2, V3, Phase currents,
Average current Iag, Peak demand currents,
Reactive power Q, Q1, Q2, Q3, Demand current
I1, I2, I3, [Us] rated supply voltage 40...300 V AC
45...65 Hz, 40...300 V DC, Network frequency
Hz, Type of network 3P, Display type 7 segments
LED, Display colour Red, Messages display
capacity 3 fields of 4 characters, Display digits
12 digit(s) - 14.2 mm in height
169 Supplying and erecting approved make suitable 21.00 Ea 43.43
panel indicator LED type lamp, lens cover,
complete erected with necessary connections.
170 Providing & erecting L.T. Current Transformer 3.00 Ea 274.72
with bar primary 50/5 to 1000/5 ratio
VA burden erected in existing CRCA box
duly secured with insulating materials
connected to the meter.
171 Providing and erecting metallic vitrified danger 6.00 Ea 69.69
notice board as per language suggested by
engineer incharge for MEDIUM VOLTAGE
installation to be erected as per IS-2551.
172 Providing following type of Modular Type 100.00 Ea 25.25
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
frame covered with textured / metallic/white
front plate , modules erected with necessary
connections as per site situation directed by
Engineer In charge.
(7) Blank Plate Single
Description Qty. Unit Rate Amount
173 Providing and erecting Approved make Earth 1.00 Ea 5415.62
fault Relay suitable to mount with inter
connection suitable to following size of moulded
case circuit breaker having CT ratio & MCCB
rating as following along with shunt trip 220V
AC. with all internal connections & complete
erected in existing M.S.housing..
174 Supplying and erecting, commissioning and 1.00 Ea 1396603.76
testing of Diesel Generating set confirming to IS:
4722:1968 & BS:5514 having continuous rating,
3 phase, 415 volts, 50 cycles A.C. supply
comprising of a totally enclosed air/water
cooled diesel engine with multi-cylinders
developing suitable BHP not less than following
capacity at 1500 RPM with 10% overload for
one hour in 24 hours with standard accessories
like fly wheel, lubricating oil cooler, "A" class
governor, heavy duty fuel wheel and lubricating
oil filter, oil bath air filler, lubricating oil
pressure gauge, end exhaust manifold, standard
set of tools with adjustable spanners, screw
drivers, cylinder head to cover, joint cylinder
head to exhaust, element lube oil filter, 12 /
volts electric starting equipment complete with
standard heavy duty battery, dynamo, cut-outs,
ammeter, necessary wiring, pressure gauge,
starter etc and heavy duty Residential type
exhaust silencer (With DEF System) and vertical
hot air duct both
logged with asbestos rope, save oil trays, -
exhaust piping of required length, standard
wall/floor mounted fuel with level indicator and
piping and drip proof alternator, self excited,
self regulated, screen protected, with excitation
system, capable of delivering the rated system
output at 415 volts, 3 phase, 0.8 PF, 50 Hz,
wire, running at 1500 RPM, conforming to IS-
4722- 1968 with voltage regulation +/- 5% of
rated voltage from no load to full load. Both the
engine and alternator fitted on a common
fabricated steel base plate with antivibration
mounting engine and alternator both
connected to each other by flexible flange
coupling and with floor/wall mounted control
panel box comprising of voltmeter ammeter,
selector switches, ACB / MCCB / MCB of
adequate capacity,
Description Qty. Unit Rate Amount
indicator lamps duly wired with HRC fuses. The -
alternator & control panel shall be connected
with provided suitable capacity armoured cable
and complete with Acoustic enclosure (canopy)
made out of 16 SWG CRCA Sheet, sound
absorbing material Rockwool of 64 density &
100 mm thick conforming to IS:8183 / PU Foam
of 40 Density - at least 40 mm. The resin bonded
rockwool covered from inside the canopy by
perforated sheet with 3/4 mm holes, sound level
not more than 75 dB at a distance of 1 mtr, as
per PVCT norms.DG set should have in built fuel
tank capacity of minimum 8 hrs of continous
running capacity on full load . Erection,
commissioning and satisfactory testing as per
requirement with first filling of fuel (minimum
up to the 80% of fuel tank capacity), oil, etc.
with guarantee / Warrantee of complete system
for Two years. & with obtaining all necessary
certificate from Electrical Inspector. The
Capacity and Ratings of DG sets are as below.
(As per new CPCB4+ Emission norms Engine
With - Turbo Charger, EGR (Exhaust Gas
Recirculation), CRS (Common Rail Fuel System),
DOC (Diesel Oxidation Catalyst), SCR (Selective
Catalytic Reduction), Integrated wiring harness
Providing to&ECU .)
erecting approved make AMF 1.00 Ea. 222714.09
control panel suitable for following size of
phase, 415 V., 50 cycles, A.C. diesel generating
set complete of scope as detailed below:
1) Power module: A pair of electromechanically
interlocked contactors (for mains & generator)
Overload relay for generator contactor Neutral
contactor for mains and generator Power socket
for connections.
2) Control and metering module: Line voltage
monitor. Generator voltage monitor Ammeter
items attempt start facility. Air circuit
breakers/MCB/MCCB of suitable rating for
auto/manual operation. Auto/manual switch.
Emergency stop push buttons. Manual start
push button. frequency meter. Engine hour
meter. Two earthing studs.
Description Qty. Unit Rate Amount
3) Protection module: The engine shutdown in -
the unlikely event of Low lube oil pressure High
cylinder head 220509temperature. V belt
4) Indicators with alarm Load on generator.
5) Indicators Load on mains Engine fails to start
. Emergency stop battery charger.
The AMF Panel of following capacity
(D) AMF Control Panel for200 KVA/250 KVA3
176 Providing and erecting XLPE(IS:7098)(I)-88 ISI 160.00 Mtr. 87.87
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables.
(B) 3 core 4 Sq. mm
177 Providing and erecting XLPE(IS:7098)(I)-88 ISI 80.00 Mtr. 107.06
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables.
(C) 3 core 6 Sq. mm
178 Providing and erecting XLPE(IS:7098)(I)-88 ISI 240.00 Mtr. 131.3
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables.
(D) 3 core 10 Sq. mm
179 Providing and erecting XLPE(IS:7098)(I)-88 ISI 80.00 Mtr. 220.18
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables (B) 3 1/2 core
Sq. mm ( 16 Sq. mm 1/2 core)
180 Providing and erecting XLPE(IS:7098)(I)-88 ISI 370.00 Mtr. 284.82
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables (C) 3 1/2 core
Sq. mm ( 25 Sq.1/2 mm core)
181 Providing and erecting XLPE(IS:7098)(I)-88 ISI 150.00 Mtr. 540.35
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables (F) 3 1/2 core
Sq. mm ( 70 Sq. mm 1/2 core)
Description Qty. Unit Rate Amount
182 Providing and erecting XLPE (IS:7098)(I)-88 ISI 290.00 Mtr. 117.16
armoured cable multistrand / Solid
Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing
trench / pipe of following size of cables
(A) 4 core 4 Sq. mm
183 Providing and erecting XLPE (IS:7098)(I)-88 ISI 220.00 Mtr. 126.25
armoured cable multistrand / Solid
Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing
trench / pipe of following size of cables
(B) 4 core 6 Sq. mm
184 Providing and erecting XLPE (IS:7098)(I)-88 ISI 135.00 Mtr. 140.39
armoured cable multistrand / Solid
Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing
trench / pipe of following size of cables
(C) 4 core 10 Sq. mm
185 Providing and erecting XLPE (IS:7098)(I)-88 ISI 180.00 Mtr. 153.52
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench /
pipe of following size of cables
(A) 4 core 16 Sq. mm
186 Providing and, fixing heavy duty flange type 32.00 Ea 33.33
brass cable gland with rubber ring for PVC
insulated armoured cable complete with out
going tails, insulating tape etc for following size
(A) 2 to 4 core 2.5 / 4 Sq. mm
187 Providing and, fixing heavy duty flange type 10.00 Ea 38.38
brass cable gland with rubber ring for PVC
insulated armoured cable complete with out
going tails, insulating tape etc for following size
(B) 2 to 4 core 6 Sq. mm
188 Providing and, fixing heavy duty flange type 22.00 Ea 38.38
brass cable gland with rubber ring for PVC
insulated armoured cable complete with out
going tails, insulating tape etc for following size
(C) 2 to 4 core 10 Sq. mm
189 Providing and, fixing heavy duty flange type 8.00 Ea 47.47
brass cable gland with rubber ring for PVC
insulated armoured cable complete with out
going tails, insulating tape etc for following size
(D) 2 to 4 core 16 Sq. mm
Description Qty. Unit Rate Amount
190 Providing and, fixing heavy duty flange type 10.00 Ea 75.75
brass double compression type cable gland
with rubber ring for PVC insulated armoured
cable complete with out going tails, insulating
tape etc for following size of cables.
(B) 3 & 1/2 core 35/50 Sq. mm
191 Providing and, fixing heavy duty flange type 4.00 Ea 140.39
brass double compression type cable gland
with rubber ring for PVC insulated armoured
cable complete with out going tails, insulating
tape etc for following size of cables.
(E) 3 & 1/2 core 120 Sq. mm
192 Solder less crimping type Aluminium lugs 152.00 Ea. 6.06
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
193 Solder less crimping type Aluminium lugs 78.00 Ea. 13.13
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
194 Solder less crimping type Aluminium lugs 32.00 Ea. 15.15
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
195 Solder less crimping type Aluminium lugs 40.00 Ea. 20.2
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
Description Qty. Unit Rate Amount
196 Solder less crimping type Aluminium lugs 16.00 Ea. 45.45
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
197 Supplying & erecting earth pit of minimum bore 16.00 Ea 8636.51
dia.150mm size approved make Earthing
Electrode consisting Pipe-in-Pipe Technology
as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of
50mm having 80-200 Micron galvanising, Inner
pipe dia of 25 mm having 200-250
Micron galvanising, connection terminal dia of
12mm with constant ohmic value surrounded by
highly conductive compound with high
charge dissipation suitable for following
type of applications with chamber and
heavy duty cover. (A)(approved make OEM has
to submit test certificate including value of
earth resistance of installation duly stamped
and signed by agency and officer Incharge
has to ensure the value of earthing
resistane mentioned in test Certificate) &
having back filling compound of (B) Inner
chemical (CCM Compound)- Resistivity:-
ohm / meter testing as per IEC 62561-2017,
< 1 volt at no load & dry form, Sulphar content:-
<2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture
for long time Necessary test report must be
198 Providing by Agency.
erecting required size HOT deep 50.00 Kg. 77.77
Galvanised iron strip for earthing of H.T. , OCB/
ACB/ Transformer LT panel board, Motors etc.
using proper clamp.
199 Providing and erecting required size Copper 40.00 Kg. 794.87
strip for earthing of H.T. OCB / ACB/
Transformer, LT panel board, Motors etc. using
200 Providing and erecting Annealed bare Copper 20.00 Kg. 794.87
wire 8 to 16 SWG.
201 Supplying and erecting approved make 10.00 Ea 2534.09
oscillating type bracket fan A.C. 23OV. 50cy/s
400/450 mm sweep wall mounted with height
adjustment and rotary tilting device complete
with guard, flexible Core plug top complete
erected with lead wires as directed. CAT II
Description Qty. Unit Rate Amount
202 Providing & erecting Approved make Ceiling Fan 10.00 Ea 1982.63
with double ball bearing with Condenser
volt A.C.50 Hz. 900 mm sweep complete having
3 Aluminium blades, canopy erected complete. [
Make shall be approved by Engineer in Charge]
203 Providing & erecting Approved make Power 80.00 Ea 1948.29
Saving 50 Watt Ceiling Fan with double ball
bearing ISI mark with Condenser 230 volt A.C.
50 Hz 1200 mm sweep complete having
3blades with aluminium blades with , canopy &
30 cm. down rod erected with earthing.(Make
shall be approved by Engineer in charge))
204 Supplying and erecting 19 / 20 mm. nominal 90.00 Mtr. 108.07
bore Medium Class M.S. Pipe down rod
erected duly painted for fan complete with
proper insulation without leakage and earthing.
205 Supplying & erecting fan hook box of 10 mm 90.00 Ea 108.07
M.S. round bar bounded to the RCC bars up to
50mm length each side and pierced through a
16 Gauge M.S. box / Heavy Duty PVC box
complete erected concealed in Ceiling with
necessary finishing.
206 Providing 2.5mm.thick laminated acrylic sheet 90.00 Ea. 18.18
to cover the fan hook or Fan box.
207 Supplying & erecting approved make low noise 35.00 Ea 1703.87
decorative exhaust fan having square frame
ABS body with inbuilt lowers & square frame.
200mm with 1350RPM Cat.II
208 Providing recess in wall or window frame 35.00 Ea 189.88
suitable for erection of Exhaust fan complete
with plastering and colour washing to match the
colour of the wall or window complete with
expanded metal in order to render the fitting in
accessible and the room water-proof.
209 Supplying and erecting led lamps with following 40.00 Ea 112.11
wattage capacity of 220 to 240 voltage,
minimum 15000 burning hours life, 500 V in
built-surge protection,Polycarbonate diffuser,
mounting suitable for E14 / E27 / B22 lamp
(A) LED Lamps integral type, with PC diffuser
suitable LAMP holder
(ii) 5 to 8 watts cat - III
Description Qty. Unit Rate Amount
210 Supplying and erecting LED indoor fittings with 100.00 Ea 427.23
LEDs of wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as a heat
sink shall be made of thick sheet Steel
conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V. &
corrosion resistance with diffuser housed in
aluminium casted body with company
160V to 270V,Power Factor more than 0.95,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed
Mount Downlight with provision for spring
loaded mounting clips complete.IP20
(ii) 12 watts, Surge-2 KV cat III
211 Supplying and erecting LED indoor fittings with 210.00 Ea 427.23
LEDs of wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as a heat
sink shall be made of thick sheet Steel
conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V. &
corrosion resistance with diffuser housed in
aluminium casted body with company
160V to 270V,Power Factor more than 0.95,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed
Mount Downlight with provision for spring
loaded mounting clips complete.IP20
(ii) 15 watts, Surge-2 KV cat III
Description Qty. Unit Rate Amount
212 Supplying and erecting LED indoor fittings with 350.00 Ea 589.84
LEDs of wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as a heat
sink shall be made of thick sheet Steel
conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V. &
corrosion resistance with diffuser housed in
aluminium casted body with company
160V to 270V,Power Factor more than 0.95,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed
Mount Downlight with provision for spring
loaded mounting clips complete.IP20
(iii) 16-20 watts, Surge-2 KV cat III
213 Supplying and Erecting Of L.E.D. type High bay 6.00 Ea 5256.04
fixture having Power Consumption of following
watts with, Input Voltage 110 - 290 V.AC with
full efficiency, Power Factor > 0.9 with 50/60
HZ, CCVC LED Driver used for maximum power
saving, Best Quality Aluminium alloy housing
and aluminium Dome for better heat dissipation,
CCT Cool white (6000K), CRI 80, Beam angle >
120 degrees, working temperature -20 deg c to
+55 deg c, Body IP
(A) 70 to 90 watts cat III
Description Qty. Unit Rate Amount
214 LED Sign Board letter as per drawing including 1.00 Sq. mtr 16191
GIDC Logo" with ACP background Supplying &
erecting with required angle iron/pipe
suppports of one complete signboard having
mm thick Alluminium Composite Panel (ACP)
fascia on the front side. 1.5" Sq. hollow pipe
structure frame with back side & surrounding 8"
cover up by 24/26 swg pre coated CRC sheet. All
text symbol made out-of Acrylic cover letters
having 3.0" embosed with LED modules &
required power supply & LEDs lighting & Acrylic
Cover letters as per text & symbol as directed by
Engineer - In Charge. The size of signboard be of
7 m x 0.9 m looking to the site area. Make: As per
approved by Engineer In charge.
215 65" UHD Interactive Display 5.00 Ea. 155150
20 point Touch WIndows, 10 point touch
3x HDMI 2.0 In, 1x DP In, 1x C=VGA In, 1x HDMI
Out, 6x USB Port, 1x SPDIF Out, 2x RJ-45, 1x RS-
1.07 Billion DIsplay Colors
Contrast Ratio: 1200:1
Brightness: 390cd/m2.
BIS certification, FCC Class A, Country of Origin
Description Qty. Unit Rate Amount
216 Full HD Recording Codec. Supports 1080p60fps 1.00 Ea. 267500
2x HDMI/DP/DVI Input Port. 2x HDMI Output.
Supports 1080p60 fps and Video Routing to any
1x Balanced XLR input. 1x Unbalanced Line
Input. 1x Balanced Line Output. 2x USB2.0
1 RJ-45 port for IP network. Support TCP/IP,
DHCP, HTTP, HTTPS with SSL/TLS, RTP, RTCP,
Input resolution: 1024x768, 1280x768,
Coding/decoding resolution: 800x600,
Output resolution: 800x600, 1024x768,
Acoustic Echo Cancellation, Automatic Gain
Control, Acoustic Noise Suppression
Support Administrator password, SSH/HTTPS.
Infra Red pass through as well as remote
upgrade through network. RS-232 Control port
for third party control.
217 Full High Definition PTZ Camera with 12X 1.00 Ea. 190425
Optical and 12X Digital Zoom.
1/2.7” HD CMOS sensor. HDMI 2.0 and USB
synchronous Video output. 1080p60 resolution
on both HDMI & USB3.0 Interface.
RJ-45 Port for Video Monitoring and Streaming
Inbuilt RTSP/RTMP Server.
4 Infra Red Identities Inbuilt.
Wide Viewing Angle of 72.5°.
High frame rate of 60FPS on USB 3.0 port as
well as HDMI Port.
TCP/IP Control, RS-232 as well as RS
218 Super Cardioid Pickup Pattern. Priority Function 2.00 Ea. 45432
for Host with Capacitive Touch Buttons.
Frequency response of 60 to 20,000 Hz.
Built In Loudspeaker with Volume Control &
3.5mm Headphone Interface.
6 Pin Connectivity with base station.
Description Qty. Unit Rate Amount
219 Super Cardioid Pickup Pattern. Capacitive Touch 6.00 Ea. 44887
Frequency response of 60 to 20,000 Hz.
Built In Loudspeaker with Volume Control &
3.5mm Headphone Interface.
6 Pin Connectivity with base station.
220 Central Control Unit with 4" Touch Screen & 3rd 1.00 Ea. 448765
Gen of audio processing algorithm
Noise suppression
1x Balanced Audio Input and Audio Output
1x Unbalanced Audio Input and Audio Output
2x 25 Watts@ 4 Ohm Amp Output.
Conferencing Modes: Nomal and Voice
RS-232, RS-485 and RJ-45 Control port.
4x Aviation 6-Pin Interface. Inbuilt recording
221 10M Control cable for HPS controller to HPS 1.00 Lot 17120
222 240 Watts or more Mixing Amplifier 1.00 Ea. 102720
4 or more Microphone Inputs with Individual
Mixed Line Ouput x1
Individual Gain Control for Microphone Inputs
4 or 16 Ohm, 100V or more Output
AC & DC Operation with Auto Cool Function
223 Digital Signal processor with inbuilt AEC.It shall 1.00 Ea. 165850
have 4 or more balanced Mic/Line Input
Interface.It shall have 4 Line output ports.It shall
have USB Audio Interface only for soft
applications.It shall support Acoustic Echo
Cancellation, Noise Reduction, AGC.
224 Wall Mount Speakers with 5 Inches Driver and 1 4.00 Ea. 21293
inch High Frequency Driver.
100V tapping. Frequency response of 60 Hz to
Maximum SPL of 104dB.
Transformer tapping of 30W/15W/7.5W/3.75W
Make & Model : AdonisAV Nyxx
Description Qty. Unit Rate Amount
225 27' HDMI 2.0 Active Optical Cable. 3.00 Lot 21293
Support data rate upto 18 Gbps.
Resolutions upto 3820x2160@60 Hz@4:4:4.
Support HDMI 2.0. Support HDCP 2.2.
Highly resistant with RF and EMI interference.
No External Power Supplies.
226 27' USB 3.0 Active Optical Cable Only. 2.00 Lot 22470
Support data rate of upto 5Gbps.
Support resolutions of upto 1080p@60 Hz or
Support USB 3.0.
Resistant with RF and EMI interference. 4mm
227 CPU shall be with Core i5 Processor. It shall have 1.00 Ea. 69550
8 GB Ram or more. It shall have 512 GB
HDD/256GB SSD or better. It shall have 2x
USB3.0 interface, 1 x HDMI interface, 1x
10/100/1000 LAN interface. It shall have 2x
USB2.0 Intrerface. It shall have genuine
windows 11 professional series Operating
System or better.
228 15U 500watt smart AV rack with colling option 1.00 Ea. 144450
229 Supplying & erecting dual channel amplifier 1.00 Ea. 11128.18
,power handling capacity of 180 watt ,four micro
phone inputs with independent level control
,built in FM tuner,with preset memories,USB
drive & SD card for MP3 playback ,100v
/telephone input with priority and
VOX,frequency response-80 Hz to 18k Hz
Philips / /distortion less than 1% @ rated
power up to 50 units [[Approved by Competent
Authority i.e. not Below the rank of Executive
Description Qty. Unit Rate Amount
230 SITC of 3LCD Lamp based projector having 1.00 Ea. 33895.6
wxga (1280x800) or better resolution with
minimum white brightness of 3800 lumens and
color brightness of 3800 lumens. The projector
should have minimum 1HDMI,1VGA input.
Having contrast ratio of 15000:1 or more. the
projector should have auto vertical key stone
correction of +/- 30 degree and Manual
Horizontal of +/-30 degree. the projector should
have optical lens, throw ratio 1.30-1.56:1. Zoom
Factor of 1.2. Lens focus Manual having focal
length 16.9mm to 20.28mm. projector should
have features like AV mute slide, quick corner
and split function and should support wireless
functionality with inbuilt wifi or wifi dongle.
[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
231 SITC of 100 inch Self Lock MW (7 x 5) Instalock 1.00 Ea. 3810.73
Slow Retraction Screen, Aspect Ratio-4:3
[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
232 SITC of Rack Mounting kit for the control unit. 1.00 Ea. 4814.67
[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
233 Providing & erecting approved make Fingerprint 20.00 Ea. 23145.16
and card based Premium Door Controller with
LCD and Keypad having following features.
(A) Optical Fingerprint and Card based Reader
(Card personality Module not included]
(B) Dot-Matrix LCD and Touch sense Keypad
(C) Built-In interfaces like door lock, door sense,
exit Reader, Exit switch, Ethernet RS485, Aux
Input & Aux Output Port
(D) 5000 Events, Access Control, Time
Attendance, Tamper Detection
(E) 4 LEDS and Buzzer
234 SITC of Ceiling speaker, 6W, metal 80.00 Ea. 649.43
[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
Description Qty. Unit Rate Amount
235 Supplying & erecting Amplifier having following 2.00 Ea. 11298.87
Power Output :250W (RMS) (300W Max.)
inputs : 6 Misc. & 2 Aux.
frequency Response :50-1500HZ I3db
Tone Controls :Cut & Boost type
LED Meter :5 LED Arrays
The amplifier suitable to operate 240V A.C.&
24volt D.C. (Battery) with automatic changeover
from AC to Battery operation, duly protected by
wrong Battery Polarity connections. [[Approved
by Competent Authority i.e. not Below the rank
of Executive Engineer ]
236 Supplying and erecting Flexible PVC insulated 750.00 Mtr. 31.31
multi strand multi core 1.1 kv grade ISI marked
copper wires of following size to be erected as
(d) 1.50 Sq.mm 2 core round PVC sheathed
237 Providing & erecting water cooler having 3.00 Ea. 55893.4
storage capacity 150 Ltr. & cooling capacity
Ltr.per hour @ an ambient temp of 45˚ C. The
outlet temp. of the water should drop by 15˚C
within a hour, The water cooler should be
comprising of hermetically sealed compressor,
fan motor, condensing unit, water tank
surrounded by evaporating, coil, thermostats,
relay etc.complete with necessary inlet & outlet
connection. The body of water cooler will be
made from Stainless Steel.
238 Supplying & erecting reverse osmosis (RO) 2.00 Ea. 93468.43
water purification system with M.S. powder
coated pedestal frame, prefilter housing carbon
filter suitable buster DC pump, auto low & high
pressure switches with following size of LPH
capacity & erected as directed
[E] 200 LPH with 1 phase / 3 phase Raw water
pump of 1000LPH @ 2.5kg/cm2 (1N0 -
Kirloskar/CRI/Lubi) , Dual media filter 10"x54"
(1 No), Micron catridge filter 20" x 2.5" - (1No),
High pressure pump 1000LPH @ 10kg/cm2 -
(1No - Shimge /CRI /Lubi) , RO Membrane
housing with RO membrane of 40*40 - (
No),RO pressure tube 4" x 1E-(1No), 0-1200LPH
Rotameter-(2 Nos). Recovery Rate 50%.
Description Qty. Unit Rate Amount
239 Supplying and erecting approved make online 5.00 Ea. 270989.06
Un-interruptible Power Supply system
comprising flat cum-boost charger with IGBT
base rectifier & Inverter & sealed maintenance
free SMF batteries. The charger having operating
capacity for input 160-270V AC & inverter
having output 230V,50 Hz Ac with 0.8 load
power factor with battery, over/under voltage
output with over load & short circuit protection
equipment. The system housed in CRC sheet
duly powder coated paint with following power
backup.with MS painted batteries stand, 10%
Overload capacity for momentary load.
(I) 10 KVA 3 - phase with 1Hr Backup
240 S.I.T.C. submersible pump set suitable for bore of 1.00 Ea. 22374.53
100 mm. dia. or more having three phase motor
capacity not more than 5 H.P. with following
capacity . Lifting and Lowering taken extra.
(B) (16 stage) 140 to 180 LPM discharge at 96 to
69 mtrs. head respectively suitable for 50mm
dia. delivery pipe cat III
241 Providing and erecting ISI marked PVC insulated 65.00 Mtr. 295.93
PVC Sheathed Flat flexible Submersible copper
cable approved make of following Size.
(E) 3 Core x 10 Sq. mm.
242 Providing & erecting open well type horizontal 1.00 Ea. 9613.18
mono block pump set with stainless steel body
having following specification
(C) 1 H.P. single phase open well motor pump
set suitable for 185 LPM discharge @ 25 mtr.
head, suitable for 32 mm dia. Delivery pipe with
243 Providing & erecting open well horizontal mono 1.00 Ea. 15707.52
block pump set with cast iron body, complete for
three phase submersible motor having
[C] For 3 HP 3 phase open well horizontal mono
block pump set suitable for 85 LPM to 270 LPM
@ 11 mtr to 33 mtr head suitable for 50/65 mm
dia delivery pipe
Description Qty. Unit Rate Amount
244 Supplying & erecting approved make Automatic 3.00 Ea. 2355.32
liquid level controller 6A. with sensor testing as
per instruction of Engineer in charge on site
complete with wiring connection with
existing wires , with copper conductor from
pump to upper and lower tank.
245 Supplying & erecting approved make motor 3.00 Ea. 7250.79
control cubical panel [Star delta] made from
16G CRCA sheet duly epoxy powder painted
inside and outside with hinged doors and
locking with suitable size of ON - OFF isolator
(AC 3 / 23 duty) main fuses. Digital volt and
current meter (in a single unit) with
micro controller based control unit and
current sensing single phasing preventer
electronic overload protection, over
voltage (Programmable) protection and under
voltage (Programmable) protection, prod less
dry run protection programming facility for
setting of all parameter like overload current,
high voltage limit, low voltage limit, dry run
limit with digital indication on seven segment
LED display for any fault like over load,
high voltage, low voltage, dry running single
crimped, electronic star delta timer, feather
touch start / stop push buttons to be erected
on angle iron frame. Grouted on wall the
contactors will be of L& T, Siemens, BCH make
(A) DOL up to 5.0 H.P.
Description Qty. Unit Rate Amount
246 Supplying and erecting approved make GRP / 220.00 Mtr. 180.79
FRP Perforated type Cable Tray
Material – Corrosion Resistant Polyester Flame
Retardant U.V. Stabilized Resin System -
Manufactured from Pultruded Sections-
Polyester Resin System, Glass Content : 55 –
% - - Standard Length : 3000mm- Support Span
– 1500mm, Deflection L/200 - Specification
NEMA FG1 1993- UV Resistant - Flame
Retardant – IS 6746 - Appendix K/UL 94, Very
Low Flammability - Specification Followed
Oxygen Index – Minimum 30% as per ASTM D
2863 - Flame Spread (Extent of Burning) –
20mm as per Standard ASTM D 635 - Tensile
Strength – 4000 – 8000 Kg/Cm2 as per Standard
ASTM D 638 - Flexural Strength – 2500 –
Kg/Cm2 as per Standard ASTM D 790- Izod
Impact Strength – 130 Kg/Cm2 as per Standard
ASTM D 256- Compressive Strength – 2500 –
5000 Kg/Cm2 as per Standard ASTM D 695-
Barcol Hardness – 50 –
(C) Width - 100mm, Pultruded “C” Channel with
35mm Sides 3mm Thickness, Loading
247 (D) Width - 150mm, Pultruded “C” Channel with 230.00 Mtr. 232.3
30mm Sides 3mm Thickness, Loading
248 (F) Width - 300mm, Pultruded “C” Channel with 320.00 Mtr. 531.26
50mm Sides 4mm Thickness, Loading
Supplying & laying under floor pregalvanised -
corrosion proof rectangular sheet steel cable
trunking of 1.6 mm thick having with stand
point load up to 1.33 ton & free from seepage of
concrete of screed water having following size of
dimensions and No of compartments (W xD x T)
249 50mm x 38mm x 1.6 mm with One 550.00 Mtr. 420
250 100mm x 38mm x 1.6 mm with One 750.00 Mtr. 600
PVC/ GI Junction cross over box for metal/ -
Al. trunking with duct entry 25mm x 38mm size
having epoxy powder coated trap lead with
corrosion & rust free having load bearing
capacity of 3.6 tons with adjustable levelling
screw of following size.
251 150mm x 150mm x 60/75 mm depth 80.00 Ea. 1050
252 250mm x 250mm x 60/75 mm depth 30.00 Ea. 1500
253 350mm x 350mm x 60/75 mm depth 25.00 Ea. 2600
254 400mm x 400mm x 60/75 mm depth 30.00 Ea. 3200
Description Qty. Unit Rate Amount
255 Supplying and erecting approved make Conical 50.00 Ea. 6403.4
Pole (Standard ) Made from HR sheet steel. The
pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS
2629/2633/4759 with required base plate and
integral Junction box consist of terminal plate of
min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud
type terminal and arrangement for cable
terminationas erected on suitable foundation
(included) with necessary GI nut-bolts/J-Bolts.
as per details given by manufacturer considering
site requirement.The length of poles are as
(C) 5 Mtr. Long 65mm Top X140 mm bottom dia,
256 Providing and erecting street light pole bracket 40.00 Ea 561.56
comprising main B Class MS pipe of
cm/require outside dia. complete with
suitable B Class M.S. sleeve tubing of
approx. 45cms.length and suitable for
mm / 80mm. / require size pole top having
sufficient fasteners for fixing the brackets and
having spread of 1 mtr. length with suitable rise
as per site condition & suitable welded
stiffener reducer and nipple with check nut
complete painted with one coat of Red oxide
/ PU base primer and two coats of Aluminium
/ PU paint. paint with following nos of arms.
[A] Single Arm bracket 1 Mtr
257 Providing and erecting street light pole bracket 10.00 Ea 758.51
comprising main B Class MS pipe of
cm/require outside dia. complete with
suitable B Class M.S. sleeve tubing of
approx. 45cms.length and suitable for
mm / 80mm. / require size pole top having
sufficient fasteners for fixing the brackets and
having spread of 1 mtr. length with suitable rise
as per site condition & suitable welded
stiffener reducer and nipple with check nut
complete painted with one coat of Red oxide
/ PU base primer and two coats of Aluminium
/ PU paint. paint with following nos of arms.
[B] Double Arm Bracket 1 Mtr
Description Qty. Unit Rate Amount
258 Supplying & erecting approved make SMC 60.00 Ea 898.9
press moulded composite FRP. loop-in, loop-
out approx. 2mm thick box complete with
Bakelite connector strip 5way(3P+N+E),DIN rail
for mounting mob & hinged doors as per
requirement having locking arrangements
with mounting clamp with nuts, bolts &
washers suitable for erection on pole
with cable clamps& earth bolt of following size
(A) 300mm x 200mm x 100mm [deep]
259 Supplying and erecting LED street light / Flood 60.00 Ea 3345.12
light fittings with High power White LEDs
wattage of 3 Watt and above assembled on
single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast
aluminum housing with smooth finish
powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate
optics/ lenses, with toughened glass with
company mark/name engraved or embossed
160 to 270 V,Power Factor more than 0.95,
THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver
efficiency > 85 %.( fittings required LM-
79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the
(A) Street Light (IP-65), Surge protection -
4KV integral and ,Light must have 440VAC
supply with over-voltage protection.
(i) above 36 to 48 watts Cat-lll
260 Supplying & erecting approved make Digital 1.00 Ea 3168.37
time switch having lithium cell 6 years
operative and operate battery backup
channel day clock with 14 memory programme,
suitable to operate on 240V + 5%, 16A with,
floating contacts Minimum switching setup time
1 minimum & LCD display. Also comprised
permanent ON/OFF switching. Programming
switches & housed in fire proof thermoplastic
enclosure & transparent cover erected as
required with necessary connection erected as
Description Qty. Unit Rate Amount
261 Supplying & erecting power contactor ,AC3 1.00 Ea 1883.65
duty for time switch complete erected as per
direction Cat III
(B) 2 pole 250V 32 Amp.
262 Supplying and erecting Flexible PVC insulated 250.00 Mtr. 46.46
multi strand multi core 1.1 kv grade ISI
marked copper wires of following size to be
erected as directed.
(e) 1.50 Sq.mm 3 core round PVC sheathed
263 Providing and erecting Pipe type earthing 50.00 Ea. 994.85
with 40 mm dia 2.5 mtr long 'B' grade G.I. pipe
with necessary coupling buch buried in
specially prepared earth pit & G.I. earth wire
of 8 SWG erected & connected as directed (For
For using salt and charcoal / coke as required
for pipe type earthing.
264 Providing & laying approved make Double 750.00 Rmt 62.62
walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same
material at required depth in existing trench for
laying of cable. below ground / road surface
for enclosing cable
(A)50 mm outer dia
265 Providing & laying approved make Double 550.00 Rmt 137.36
walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same
material at required depth in existing trench for
laying of cable. below ground / road surface
for enclosing cable
(D)120 mm outer dia.
266 providing and erecting Miniature circuit breaker 50.00 Ea. 112.11
single pole 6A to 25A suitable to operate on
V A.C. system and having breaking capacity
KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark
267 Making trench in Hard Murrum / Tar Road 350.00 Mtr. 74.74
of suitable width of 90 cm or required depth
for laying any size of cable or locating the fault
all over the run and back filling the same
and making the surface as normal ground.
Description Qty. Unit Rate Amount
268 Making trench in soft soil of suitable width of 90 550.00 Mtr. 55.55
cm deep for laying cable or locating the fault
all over the run and back filling the same and
making the surface as normal ground.
269 Supplying & erecting carbon dioxide (CO2) fire 18.00 Ea 6591.26
extinguisher user of following capacity
with necessary clamps made from 50 x 6 mm
M.S. Flat with nut & bolts grouted in wall
[A] For 4.5 Kg Capacity
270 Supplying & erecting ABC powder type 18.00 Ea 848.4
'Ceasefire' type Fire extinguisher as per IS
13849 or 1 Kg capacity with necessary clamp
for erection on wall
271 SITC of Analogue Addressable Multi- Sensor 100.00 Ea 4500
which is fully compatible with Analogue
Addressable Protocol,having removable high
performance chamber with Twin fire LED's
allow 360 degree viewing, User selectable
sensitivity modes 1% to 4.5% obs/m,
Incorporate Optical and dual Heat elements, lock
mechanism (sensor to base), Electronically
addressed, Pulsing/non-pulsing controlled from
panel. Approved by LPCB & VdS. (Including Five
year free maintenance with guarantee)
272 SITC of sensor isolator mounting base, includes 6.00 Ea 2400
stainless steel contacts, slim profile - only 8mm,
quick connection via square cable clamps,
facility for remote indicator, Approved by LPCB
(Including Five year free maintenance with
273 SITC of Analogue Addressable Manual Call Point 6.00 Ea 6000
with Integral Short Circuit Isolator, Analogue
Addressable Protocol having, Bi-coloured status
LED (red for alarm, amber for (short-circuit),
Non-frangible element fitted as standard
(conforms to EN54), pulsing/non-pulsing can
selectable via panel, Electronically addressed,
Approved by LPCB. (Including Five year free
maintenance with guarantee)
Description Qty. Unit Rate Amount
274 SITC of addressable loop powered Base sounder 6.00 Ea 7500
with integral Beacon, includes 51 user-
selectable tones (all tones EN54-3 compatible),
variable sound output 50 ~ 98 dB(A) (±2 dB(A))
output at 1 metre, Auto shut down feature
prevents noise pollution, 'O' rated beacon to EN-
23, IP21 rated for internal use, sounder and
beacon can operate independently, Approved by
LPCB (Including Five year free maintenance
with guarantee)
275 Supplying & laying of 2x1.5 sqmm fire alarm 1000.00 Mtr. 122.881356
armoured cable, 600/1000V rated with
annealed copper conductor having XLPE
insulation, steel wire armouring & FRLS
outer sheath complete as required.
276 SITC of Microprocessor based Net-workable 1.00 Ea 219000
Analogue Addressable Fire Alarm Control Panel.
The Panel shall be compliant with EN54-2, EN54-
4 and approved by LPCB. The Fire Alarm Control
Panel shall have inbuilt 3 loops and expandable
upto 4 Loops. The Panel must have large graphic
display. The Panel must also have the capability
to take Addressable Intelligent Wired and
Wireless Devices on same loop. Each loop shall
have a capacity of 127 analogue Addressable
devices and 127 Base sounders/Base Sounder
Beacons. The Panel shall have 240 V AC power
supply along with automatic Battery Charger.
Approved by LPCB (Including Five year free
maintenance with guarantee)
Supply, Installation, Testing and Comissioning of -
Fire Supression System.
277 Contains FK-5-1-12 Fire Suppression Fluid 1.00 Ea 39344
(2.5lbs/1.14kgs), ECS Cylinder bracket (1), EOL
Adapter W/Pressure Gauge (1), Rubber
Grommets (4), Plastic Loop Clamps (25)
278 Pressure Switch point 5 bar / Signal Generator 1.00 Ea 2832
279 UL Listed Head Detection Tube (Red Colour) 8.00 Ea 1138
280 Master Control Unit with Audio Visual Alarm 1.00 Ea 11372
281 End of Line Plug UL Listed 1.00 Ea 1500
Description Qty. Unit Rate Amount
282 AUTOMATIC PUMPING SYSTEM: (PUMP ROOM) 2.00 Set 185275
Main Fire Hydrant/Sprinkler Pump- Electric
SITC of: Back pull out type -Single Stage, Self
Mriming, Centrifugal Pump for Main Fire Pump
with Electric Motor, Base frame and Couplings.
MOC:-Casing-CI, Impeller- Bronze, Shaft- SS
Flow Capacity: 1680 LPM
Speed: 2900 Approx
Pump shall be capable of furnishing not less
than 150% of rated capacity at a head not less
than 65% of rated head The shut off head shall
not exceed 120% of rated head.
UOM:-Price Per Complete set of Pump + Motor +
Note:-01. Minor civil work like tank hole/ Core
Cutting etc. are in bidders scope.
Location: In Pump Room
Make: Kirloskar / Lubi
283 Jockey Fire Pump- Electric Motor Driven: 1.00 Set 100625
SITC of: Back Pull-out End Suction Type -Single
Stage, Self Priming, Centrifugal Pump for Jockey
Fire Pump with Electric Motor, Mechanical Seal,
Base-frame and Couplings.
MOC:-Casing-CI, Impeller- Bronze, Shaft- SS
Flow Capacity: 180 LPM
Speed: 2900 Approx
Pump shall be capable of furnishing not less
than 150% of rated capacity at a head not less
than 65% of rated head The shut off head shall
not exceed 120% of rated head.
UOM:-Price Per Complete set of Pump + Motor +
Note:-01. Minor civil work like tank hole/ Core
Cutting etc. are in bidders scope.
Location: In Pump Room
Make: Kirloskar / Lubi
Description Qty. Unit Rate Amount
284 Standby Fire Pump- Diesel Engine Driven 1.00 Set 39600
SITC of: Diesel Engine driven Standby Pumping
System complete with,diesel engine, Back Pull-
out Type Single Stage, Self Priming, Centrifugal
Pump, Couplings & Base-frame:
MOC:- Pump Casing-CI, Impeller- Bronze, Shaft-
SS410, Sleeve- SS410.
Flow Capacity: 1680 LPM
Speed: 2900 LPM
Diesel Engine includes 100 ltr diesel tank,
battery, battery charger, engine oil and coolant.
UOM:-Price Per Each Set.
Note:-01. Minor civil work like tank hole/ Core
Cutting etc. are in bidders scope.
Location: In Pump Room
Make: Kirloskar / Lubi
285 Fire Pump Control Panel- Auto and Manual 1.00 No. 87910
Supply, Installation and Testing of: Electric
Control Panel for Electric Motor Driven Main
Fire Pump and Jockey Fire Pump. all pumps can
be Start Automatically (by Pressure Switch) &
Design As per the Detail Specifications given.
UOM:-Price Per Set.
Location: In Pump Room
Make: Kirloskar / Lubi
286 Air Vessel: 1.00 No. 40250
SITC of Pressurized Air Vessel f Size 450 mm Dia
x 2000 mm long fabricated from 10 mm thick
MS Plate with 25 mm drain valve, air release
valve with ball valve on top and isolation valve.
287 Providing and erecting XLPE(IS:7098)(I)-88 ISI 40.00 Rmt 265
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall FRLS
type with necessary clamps or in existing trench
/ pipe of following size of cables
- 3.5 core 35 Sq. mm
288 Providing and, fixing heavy duty flange type 8.00 No. 370
brass cable gland with rubber ring for PVC
insulated armoured cable complete with out
going tails, insulating tape etc for following size
- 3.5 core 35 Sq. mm
Description Qty. Unit Rate Amount
289 Solderless crimping type Aluminium lugs 32.00 No. 468
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
290 Providing and erecting XLPE(IS:7098)(I)-88 ISI 20.00 R.mtr 242
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall FRLS
type with necessary clamps or in existing trench
/ pipe of following size of cables
- 4 core 16 Sq. mm
291 Providing and, fixing heavy duty flange type 4.00 No. 587
brass cable gland with rubber ring for PVC
insulated armoured cable complete with out
going tails, insulating tape etc for following size
- 4 core 16 Sq. mm
292 Solderless crimping type Aluminium lugs 16.00 No. 700
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
293 Pressure Gauge with Siphon Tube and Cock. 6.00 No. 1150
Supply, Installation and Testing of: Pressure
Gauge with Siphon Tube and Cock.
MOC:-4” Dial- Glycerin filled- Stainless Steel
Body Pressure Gauge with GI Siphon Tube
Size:-Dial: 4” (100 mm)
Range: 0 – 16 Bar (kg/cm2)
UOM:-Price Per Unit
294 Pressure Switch with Siphon Tube and Cock. 4.00 No. 1265
Supply, Installation and Testing of: Pressure
Switch with Siphon Tube and Cock.
Size:- Range suitable for System Design
UOM:-Price Per Unit
Description Qty. Unit Rate Amount
295 Pipe Laying. -
Supply, Fabrication, Installation, Hydro Testing
& Painting of Under Ground Pipe.
With necessary Pipe Fitments (Flanges, Bands,
MS Support/Clamps/Hangers etc.
Hardware (Gaskets, Nut-Bolts, Paint, Wraping-
Consumables (Welding Rod, etc.) and Labour
Quality: GI, C-Class (Heavy).
UOM:-Price Per Running Meter
a Size: 150 mm 95.00 R.mtr 3380
b Size: 80 mm 10.00 R.mtr 1890
296 Pipe Laying. -
Supply, Fabrication, Installation, Hydro Testing
& Painting of Above Ground Pipe.
With necessary Pipe Fitments (Flanges, Bands,
MS Support/Clamps/Hangers etc.
Hardware (Gaskets, Nut-Bolts, Paint etc.),
Consumables (Welding Rod, etc.) and Labour
Quality: GI, C-Class (Heavy).
UOM:-Price Per Running Meter
b Size: 150 mm 270.00 R.mtr 2819
c Size: 100 mm 60.00 R.mtr 1907
d Size: 80 mm 50.00 R.mtr 1435
e Size: 65 mm 45.00 R.mtr 1145
f Size: 50 mm 45.00 R.mtr 892
g Size: 40 mm 110.00 R.mtr 690
h Size: 25 mm 215.00 R.mtr 418
297 Gate /SluiceValve -
Supply, Installation and Testing of: Gate/ Sluice
(Rising Spindle -Screw & Yoke Type) Valve with
necessary pipe fitments, hardware and
MOC:-Body: Cast Iron, Disk: Cast Iron, Seat:
Nitrile, Stem: SS. (With Flange Ends).
Standard: ISI Marked.
UOM:-Price Per Each No.
a Size: 100 mm 6.00 No. 25000
b Size: 80 mm 2.00 No. 18250
298 Check Valve -
Supply, Installation and Testing of:
Check Valve (Ball type or Swing type) with
necessary pipe fitments, hardware and
MOC:-Body: Cast Iron (With Flange Ends).
Standard: ISI Marked.
UOM:-Price Per Each No.
Description Qty. Unit Rate Amount
a Size: 150 mm 3.00 No. 6585
b Size: 80 mm 1.00 No. 2780
c Size: 50 mm 1.00 No. 1770
299 Butterfly Valve -
Supply, Installation and Testing of: Butterfly
Valve with necessary pipe fitments, hardware
and consumables.
MOC:-Body: Cast Iron, Disk: SS, Seat: Nitrile.
UOM:-Price Per Each No.
a Size: 150 mm 2.00 No. 4315
b Size: 100 mm 6.00 No. 2910
c Size: 80 mm 2.00 No. 2220
d Size: 50 mm 3.00 No. 1565
300 Strainer. -
Supply, Installation and Testing of: Y Type
Strainer with necessary pipe fitments, hardware
and consumables.
MOC:-Body: Cast Iron, Mesh: SS-304.
Working Pressure: 10 Bar
UOM:-Price Per Each No.
a Size: 150 mm 1.00 No. 40000
301 Air Release Valve- 25 mm 2.00 No. 1175
Supply, Installation and Testing of: Air Release
Valve Check Valve with necessary pipe fitments,
hardware and consumables.
MOC:-Body: Gunmetal / SS.
UOM:-Price Per Each No.
302 FIRE HYDRANT, SPRINKLER & ACCESSORIES 9.00 No. 3735
Fire Hydrant Landing Valve (Stainless Steel (SS-
304), ISI Marked):
Supply, Installation and Testing of: Fire Hydrant
Landing Valve with necessary pipe fitments,
hardware and consumables.
MOC:-Body: Stainless Steel (SS-304), Working
Parts: Stainless Steel (SS-304), Coupling:
Stainless Steel (SS-304),
Standard: -ISI Marked.
Size:-63 mm (Flange End: NB 75 mm, PCD
UOM:-Price Per Each No.
303 Fire Hose Pipe (Delivery Hose)- 63 mm x 15 m 18.00 No. 3100
Supply, Installation and Testing of: Fire Hose
with Hose Couplings.
RRL (ISI Mark- Type A) Fire Hose.
Hose Couplings: ISI Marked Stainless Steel.
With SS Wire Binding.
Standard: - ISI Marked & TAC Approved Hose.
Size:-63 mm dia x 15m long Hose.
UOM:-Price Per Each Set.
Description Qty. Unit Rate Amount
304 Cabinet For Fire Hose (Hose Box)- Double Type 9.00 No. 2635
Supply, Installation and Testing of: Fire Hose
Cabinet (Hose Box) suitable to accommodate
no. of 15 m long fire hoses and 01 no. of nozzle.
With Lock-n-key facility. Wall Mounting Design.
MOC: 16 Gauge MS Box with Powder Coating
Standard: - As per Guidelines.
Size:- Suitable for 02 nos. of 15 m long hoses.
UOM:-Price Per Each No.
305 Fire Hose Nozzle- Short Branch Pipe Nozzle. 9.00 No. 1150
Supply, Installation and Testing of: Short
Branch-pipe Nozzle.
MOC: Stainless Steel (SS-304).
Standard: ISI Marked, Heavy Quality.
Size:- 63 mm X 20 mm
UOM:-Price Per Each No.
306 Fire Hose Reel Set (ISI)-19 mm x 30 m -Rubber 3.00 No. 5485
Supply, Installation and Testing of: Fire Hose
Reel Set with necessary pipe fitments, hardware
and consumables.
MOC:-Drum: 16 G Powder Coated MS,
Hose: 19 mm X 30 m heavy-duty RUBER hose.
Shut-off Nozzle: SS-304.
With Control Valve: SS- 25mm Ball Valve.
Standard: ISI Marked. Heavy Quality.
Size:-19 mm dia x 30m long Hose.
UOM:-Price Per Each No.
307 Fire Service In-let (In-let Connection for Fire 2.00 No. 5660
Brigade)-4 Way Type.
Supply, Installation and Testing of: Fire Service
Inlet with necessary hardware and
MOC:-Body: Heavy-duty CI.
Couplings/NRV: Gunmetal.
Standard: -Made As per IS Standard- Heavy duty
Size:-Couplings: 63 mm, 150 mm E-table Flange
UOM:-Price Per Each No.
Description Qty. Unit Rate Amount
308 Sprinkler Head/ Nozzle. 220.00 No. 126
Supply, Installation and Testing of: K
Pendent type Standard Response Sprinkler
rating of 57 deg.C. with required accessories.
Standard: UL Listed
Size:-15 mm (1/2”)
UOM:-Price Per Each No.
309 Flow Switch 3.00 No. 4315
Supply, Installation and Testing of: Flow Switch
with necessary pipe fitments, hardware and
UOM:-Price Per Each No.
With all wiring/ cabling up to control panel and
all electrification.
310 Providing and erecting XLPE(IS:7098)(I)-88 ISI 500.00 Rmt 185
armoured cable multistrand Copper conductor
for 1.1 KV. to be laid on wall FRLS type with
necessary clamps or in existing trench / pipe at
road crossing or floor of following size of cable.
(a) 3 core 2.5Sq. mm
311 Providing and, fixing heavy duty flange type 14.00 No. 585
brass cable gland with rubber ring for PVC
insulated armoured cable complete with out
going tails, insulating tape etc for following size
(a) 2 to 4 core 2.5 Sq. mm
312 Solderless crimping type Aluminium lugs 56.00 No. 667
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
313 Providing and fixing, testing and commissioning 3.00 No. 1565
of Drainning Valve 50mm dia with by pass drain
connection as required.
314 Fire Extenguisher Providing and fixing, testing 3.00 No. 26165
and commissioning of CO2 type Fire
Extinguisher of capacity 22.5 kg filled with Co2
Gas as per IS 15222 with controll discharge
mechanism fitted with Hose, Horn & TROLLEY
confirms to IS 2878 bearing ISI mark. Co2
Cylinder as per IS
Description Qty. Unit Rate Amount
315 Fire Extinguisher- ABC Powder type, 6 kg. 18.00 No. 2645
Supply, Installation and Testing of: ABC Powder
Fire Extinguisher necessary hardware and
Stored Pressure Mechanism.
Charged with MAP-50 % (ABC) Dry Powder.
With wall mounting clamp.
Size:-6 kg Powder.
UOM:-Price Per Each No.
316 Fire Extinguisher- CO2 Gas type, 4.5 kg. 18.00 No. 5465
Supply, Installation and Testing of: CO2 Gas Fire
Extinguisher with necessary hardware and
Standard: - Confirming to IS: 15683-2006 with
UOM:-Price Per Each No.
317 Supplying FIRE bucket round bottom of 9 litres 4.00 No. 3220
capacity made out of 24 gauge G.I. sheet with
extra handle at bottom duly painted white inside
and Red out side with FIRE mark, filled with
dry-sand and kept on existing stand provided or
hung on wall hook.
318 Supplying and erecting floor mounting stand for 1.00 No. 4600
keeping four nos. of FIRE buckets comprising
1500 mm in length, 900 mm height frame made
out of 30mm X30 mm X 4 mm angle iron with
cross supports for legs, welded with 4 hooks and
duly painted with one coat of red lead and two
coats of approved enamelled silver paint.
319 Safety Signage- Night Glow Type: 50.00 Nos 575
SIRC of: Single Side Printed Night Glow (Glow in
Dark ) Safety Signage. Printed on PVC sticker
sheet and pasted on 3-5 mm thick PVC foam
Size: 10” X 10”.
320 CIVIL MISCELLANEOUS ITEM RCC Hume Pipe: 95.00 Rmtr 850
Providing and Laying NP3 RCC Hume Pipe of
300 mm at road crossing
Description Qty. Unit Rate Amount
321 CERTIFICATION & FIRE N.O.C. CHARGES 1.00 Nos 100000
Approval of Fire Hydrant & Entire Fire
Protection System from Local Fire Authority and
any other relevant statutory authority at initial
and various other stages of work, including
preparation of report/drawings as per fire
authority requirement. Contractor shall include
cost of all liason work which are not explicitly
mentioned above but are mandatory to have fire
authority approval (any statutory charges will
be paid extra).
322 (a) General Features & Special Features of the 1.00 Ea. 1903349.04
all lift items shall be taken as below.
(A) GENERAL DESCRIPTION OF LIFTS.
[1] GEAR LESS LIFT DRIVE (MRL) comprising of
High Starting torque Lift 3 phase 440 V A. C.
Permanent Magnet Synchronous motor of
proper rating with high efficiency shall be
used.[2] Micro processor based / PLC, ACVVVF,
vector control drive with encoder feedback
closed loop system shall be used for lift car and
door operation which shall be full collective
selective operation hall call demand response,
UP/DOWN hall stops, Main, Up/ Down
Contactor with overload and phase reversal
relay and safety controls.
[3] Car with M S platform with bracings of
adequate size and to sustain the impact load
cabin + passenger with safety factor of fire for
steel and side panels of Stainless steel of sheet of
grade 304 duty. Car ceiling will be S.S. finishes
with aesthetic appearance with LED ceiling
lights. Car flooring shall be of s/s 304 chaker
plate design sugeested of engineer in charge. of
engineer in charge. Car doors shall be of
stainless steel grade 304, hairline finish with
centre opening / telescopic automatic doors. Car
panel will also be S.S. 304 finished with
emergency stop device, mechanical door safety
device, facility of auto/ attended mode. All car
panel buttons and all floor switches must be
with brail language as per lift act.
Description Qty. Unit Rate Amount
[4] All landing doors must be fire rated for
hour shall be fully automatic centre opening/
telescopic opening made of hairline finish steel
grade of 304 with key holes and infrared
curtains with Unlocking facility from outside
[5] Appropriate battery operated emergency
light in the car along with alarm switch shall be
provided. Also, Emergency Light & Fan should
start immediately without any Time Delay as
soon as power fails.
[6] Digital scrolling indicator system for up-
down arrow along with floor position indicator
shall be provided inside the car and at all floors.
[7] Full height infra red curtain with multiple
cross / crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be
provided accordingly of passenger capacity with
Manual Rescue Operation ( Manual Cranking
[9] Audio visual indication in the lift car showing
over loading shall be provided such that doors
kept open till excess load is removed.
[10] Spring buffers/PU Buffers shall be
[11] Car fan as per passenger capacity with
automatic sleep timer shall be provided.
[12] Voice annunciator with suitable music shall
be provided in lift car.
[13] Self diagnostics system for operational and
safety parameters shall be provided in control
[14] Mechanical over speed governor with
governor calibration as per actual site
parameters and submission of calibration
certificate submission, door key holes in the
floor doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the
lift machine room and monkey ladder for lift pit
should be provided by the lift agency, along with
the other steel structure works, foundations for
the machine etc…
[16] In the hoist way fascia plate shall be
provided without any extra cost, where ever
required as / if directed by engineer in charge.
Description Qty. Unit Rate Amount
[17] Permanent wiring with necessary safety
devices like RCCB in all circuit, Over Voltage
Under Voltage protection and THD eliminator in
circuit for lift machine room and lift well with
proper numbers of light points, with fixtures,
exhaust fan and plug points shall be provided by
the agency. Only 3 phase Power Supply shall be
made available by department in lift machine
room. Necessary Earthing as per Lift Act/Rules
shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional
and alteration in lift shaft and machine room
related to erection of lift shall be made by lift
agency without any extra cost. (granite/marble
fixing around all landing door openings are not
in lift agency’s scope.)
[19] Agency has to provide all working drawings
and documents and liaison services for
obtaining all necessary permission from lift
inspector and other authorities. [20] acrylic
transparent licence/display A4 size holder in lift
[20A] As per statutory requirement of Govt. Of
Gujarat lift & escalator act 2000, lift agency has
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection
during/after lift erection and provide report by
third party authorized by concern licensing
authority 5.agency has to provide third party
insurance upto completion of free maintenance
period and submit the document for the same.
Description Qty. Unit Rate Amount
[21] Car Panel Operating Buttons with floor
position indicator/buttons must be of Auto Glow
type clearly visible when view from inside cabin.
[22] For Physically Handicapped person Full
Length Handrails of hairline finish steel grade of
304 should be provided at appropriate height
on the Rear & Side Wall Panels in Lift Car. [23]
With Necessary KVA rating voltage controlled
Stabilizer suitable for your controller, drive and
all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb
required for lift is in scope of work which rating
is sugested by CEICED Department (electrical
DESCRIPTION OF LIFT :
Supplying, Erecting, Testing & Commissioning
the passenger lift having following main
15/16 Passengers, Ground plus 2 upper floor
with Rated Speed of 1.0 m/sec.,
(C) With General PLUS ADDITIONAL SPECIAL
FEATURES attached herewith. Prem. Cat.
323 Providing and erecting Inverter based approved 10.00 Ea. 44659.17
make split air-conditioning unit consisting of
condensing unit with variable speed fan motor,
inverter type hermetically sealed rotary
compressor with accessories etc. duly connected
separately erected evaporating unit and blower
motor with its accessories by means of extra
supplied proper insulated copper tubing,drain
PVC pipes suitable for ( cost includes Eco
Friendly green gas charging and 15A plug top &
Remote Control & MS Stand) with necessary
(2)For ISEER Range (KWH/KWH)(4.0 to 4.49)
(A) for 1.0 ton capacity- Premium Cat.
Description Qty. Unit Rate Amount
324 Providing and erecting Inverter based approved 12.00 Ea. 69368.82
make Cassette type split air-conditioning unit
consisting of condensing unit with fan motor,
hermetically sealed scroll/rotary compressor
with accessories etc. duly connected separately
erected evaporating unit and blower motor with
its accessories by Eco friendly Green gas
charging & Internal copper wiring & Remote
control ( 3 star and above of current year) with
necessary core cutting.
(A) for 1.5 ton capacity (1 Way)
325 Providing and erecting Inverter based approved 10.00 Ea. 80731.32
make Cassette type split air-conditioning unit
consisting of condensing unit with fan motor,
hermetically sealed scroll/rotary compressor
with accessories etc. duly connected separately
erected evaporating unit and blower motor with
its accessories by Eco friendly Green gas
charging & Internal copper wiring & Remote
control ( 3 star and above of current year) with
necessary core cutting.
(B) for 2 ton capacity (1 Way)
326 Providing and erecting Inverter based approved 5.00 Ea. 69368.82
make Cassette type split air-conditioning unit
consisting of condensing unit with fan motor,
hermetically sealed scroll/rotary compressor
with accessories etc. duly connected separately
erected evaporating unit and blower motor with
its accessories by Eco friendly Green gas
charging & Internal copper wiring & Remote
control ( 3 star and above of current year) with
necessary core cutting.
(A) for 1.5 ton capacity (4 Way)
327 Providing and erecting Inverter based approved 11.00 Ea. 80731.32
make Cassette type split air-conditioning unit
consisting of condensing unit with fan motor,
hermetically sealed scroll/rotary compressor
with accessories etc. duly connected separately
erected evaporating unit and blower motor with
its accessories by Eco friendly Green gas
charging & Internal copper wiring & Remote
control ( 3 star and above of current year) with
necessary core cutting.
(B) for 2 ton capacity (4 Way)
Description Qty. Unit Rate Amount
328 Providing and erecting Inverter based approved 1.00 Ea. 131862.57
make Cassette type split air-conditioning unit
consisting of condensing unit with fan motor,
hermetically sealed scroll/rotary compressor
with accessories etc. duly connected separately
erected evaporating unit and blower motor with
its accessories by Eco friendly Green gas
charging & Internal copper wiring & Remote
control ( 3 star and above of current year) with
necessary core cutting.
(C) for 3 ton capacity- 1/3Phase (4 Way)
329 Supplying and erecting insulated pair of soft 300.00 Mtr. 965.56
copper tubing open or concealed including
power and control cable,necessary PVC drain
pipes for Split AC machine up to 4 TR capacity
330 Supply, Installation, Testing and Comissioning of 94.00 Ea. 11345
4MP Varifocal Lens Dome Type Camera, H.265
4MP IR Turret Dome N/W Camera, Manual
Varifocal 2.8-12mm, 50M, Micro SD,
DC12V/PoE, IP67/IK10, Basic IVA, 4MP
resolution (2560 × 1440), True day/night,
Digital WDR, 3D DNR, HLC & BLC, Triple
streams, Smart codec by ROI, Built in MIC, Cyber
Security, Basic intelligent video analytics, Audio
In, NDAA Compliance, UL, CE, FCC Certified
(Including Five year free maintenance with
331 Supply, Installation, Testing and Comissioning of 10.00 Ea. 11345
4MP Varifocal Lens Bullet Camera, H.265 4MP IR
Bullet N/W Camera, Manual Varifocal 2.8-
12mm, 50M, Micro SD, DC12V/PoE, IP67/IK10,
Basic IVA, 4MP resolution (2560 × 1440), True
day/night, Digital WDR, 3D DNR, HLC & BLC,
Triple streams, Smart codec by ROI, Cyber
Security, Basic intelligent video analytics, NDAA
Compliance, UL, CE, FCC Certified (Including
Five year free maintenance with guarantee)
Description Qty. Unit Rate Amount
332 Supply, Installation, Testing and Comissioning of 2.00 Ea. 314526
64 Channel Network Video Recorder (NVR),
Dual OS design, HDD Hot Swap with RAID
support, N+1 hot spare configuration, Support
16CH@2MP, H.265/H.264 Video Compression,
HDMI, VGA output, up to 8 SATA interface each
with max 10 TB support and 1 eSATA, 16-ch
synchronous playback at up to 1080p
resolution, Gigabit Ethernet network interfaces,
bandwidth 320 mbps, CE FCC, BIS, Operating
Temp -10 deg to 50 deg C, USB and serial
Interface, RAID
supported (Including Five year free
maintenance with guarantee)
333 SITC of SCREEN SIZE 80 cm diagonal (32” 3.00 Ea. 50400
INCH), RESOLUTION HD (1366*768), USB
INPUT (2.0 SUPPORT) 2*Side(USB2.0), HDMI
INPUT 3*Side(HDMI 1.4), USB DEVICE SUPPORT
USB Supported HDD, HOTEL MODE Yes, Basic,
BLUETOOTH Yes (Ver. 4), WIFI
TYPE(STANDARD) 802.11a/b/g/n 2.4G 2T2R,
Built-in, WIFI BAND TYPE 2.4GHz, OS &
VERSION INFO Android 'P' - 9.0, MEMORY
FLASH 8GB EMMC, RAM 1.5GB , DDR3
Mhz. (Including Five year free maintenance
with guarantee)
334 SITC of 48 x 10/100/1000BASE-T ports 4 x 5.00 Ea. 30398.98
Gigabit GbE/SFP combo ports Advanced L2
switching and security features
L2+ Static Routing Optional “standard mode” or
“surveillance mode” management user interface
[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
335 Supply, Installation, Testing and commissioning 1.00 Ea. 15665
of 4 TB Surveillance Series Hard disk supporting
24X7 operational efficiency
336 Providing & Erecting Netwrok rack with 1.00 Ea. 11440.678
following capacity with Necessary cooling
fan,Cable manager,6A PDU,equipment rack with
necessary mounting accessories.
337 Providing & Erecting Netwrok rack with 1.00 Ea. 30508
following capacity with Necessary cooling
fan,Cable manager,6A PDU,equipment rack with
necessary mounting accessories.
Description Qty. Unit Rate Amount
338 Supply, Installation, Testing & Commissioning of 50.00 Per KW 42156.39
following size of Grid Tied Solar Power Plant
Solar Panels (ALMM approved): Frame Material
: Anodized Aluminum alloy Frame With Twin
Wall Profile, Front Cover : High Transmission
Low-Iron Tempered Glass (AR Coated), High
efficency and positive power tolerance Pmax:
0/+5, Module Efficiency should be approx. 18%-
21%, Normal operating temperature 45'C,
Junction Box with Waterproof IP67 & MC4
Compatible and Enclosed with Bypass diodes,
100% Electroluminescence test to ensure error
free Modules, Thep. temp. co-efficient of the PV
module shall equal or better than -
0.45%/degree C. Solar PV modules of minimum
fill factor 75% to be used. Unit Production:- 4 to
5 Unit /kw /day (Actual)(1Year Avg) With
year Product warranty and 25 year Linear
Power Warranty.,
Solar Inverter: MPPT Range: 80-1000 V, Max
efficiency: 97.5% - 98.9%, O/p Frequency:
50/60Hz, Operating Altitude (m) ≤4000, O/p
Power Factor: ~1, O/P THDi: <3%, Operating
Tempreture Range: -25~60°C, Anti-islanding
Integrated, Input Reverse Polarity Protection -
Integrated, Insulation Resistor Detection
Integrated, Residual Current Monitoring Unit
Integrated, Output Over Current Protection
Integrated, Output Short Circuit Protection
Integrated, Output Over Voltage Protection
Integrated, Protection Degree: IP65, User
Interface LCD & APP,Datalogger &
Communication: GPRS / Wi-Fi, Module
Mounting Structure: Seamless Box Pipe / 'C'
Channel of suitable size for rooftop solar
installations with good stability agaist wind &
weight load., Hot Dipped Galvanized steel coils.
suitable arrangement for base plate for
foundation , solar panel mounting, the structure
should be suitable for carry the load of solar
panel,wiring, sprinkler system etc. with
necessary foundation work/wall mount, j bolt,
anchor fastner etc. the nut bolt used for
installtion of stucture should be (SS 304)
quality. and Balane of System with necessary
Swithgears (Suitabel size and protection of
ACDB & DCDB), inter connecting wiring,
earthing system, lightining arrester system, all
liasoning work with various gov. dipartment like
state nodal agency,DISCOM & CEIG is included in
Description Qty. Unit Rate Amount
(Excluding GEDA Application fees, Solar -
connectivity Charges, Meter connectivity
Charges, Meter testing Charges.)
(D) Grid Tied Solar Power System: 26 - 50 kW (3 -
339 Providing & erecting Automatic solar panel 50.00 Per KW 3681.45
cleaning system for solar power projects which
includes necessary plumbing work (UPVC pipes
and accessories) from source of water to project
site (upto 30 meters),Suitable size of sub
mercible/ open well motor, necessary wiring for
motor and sprinkler system with safety, timer
circuit for automatically on/off the sprinkler
system, necessary size oand number of
nozzles/JET (minimum 1 Nozzle/Jet per
(D) 21KW-50KW Cleaning System -
340 Providing, erecting, testing & commissioning 1.00 Ea. 678301.86
approved make oil immersed ONAN cooled,
double wound, core type indoor / outdoor
copper wound 11KV/ 433V step down
transformer of following capacities operating on
3 phase, 50 Hz 4 wire & neutral earthed system
continuously rated for a full temperature rise in
oil not exceeding 45 Deg.C.at maximum ambient
temp. of 50 Deg. C. complete with necessary
radiator first filling of new transformer oil &
standard fitting as below complying with IS
1180( Part 1 ):2014 standards with energy
efficiency level
On load tap changing range steps +2.5% to -5% -
on H.V for variation should be provided. The
H.V. shall be connected Delta & Secondary with
star connection. The transformer should have
cable-end boxes on H.T. side suitable for up to
core 150 sq.mm. XLPE cable & on L.T. side
suitable for bus duct or cables as per
requirement complete with test certificates from
1. Oil conservator with filling Hole & Cap - -
2. Thermometer pocket with 6" dial type -
thermometer switch alarm & trip contacts-
3. Silica-gel breather with charge- One No. -
4. Plain oil level gauge - One No. -
5. Drain / Sampling / Filter valve- One No. -
6. Top Filter Valve - One No. -
Description Qty. Unit Rate Amount
7. Explosion vent with Diaphragm - One No. -
8. Rating & Diagram plate - One No. -
9. Additional neutral bushing for earthing - -
10. Bi directional Roller - Four Nos. -
11. Earthing terminals - Two Nos. -
12. Lifting lugs - Two Nos. -
13. Air release plug. - One No. -
14. Double float buchholz relay with Alarm and -
15. Control cable as required from Transformer -
to VCB Panel is to be provided with necessary
connection to VCB relays for protection.
as per IS 1180 level-2 -
Max. allowable loses at 50 % of rated load is
0.98 KW and at full load is 2.93 KW
341 Providing, and erecting 11 KV D.P. 9 mtr. high 1.00 Ea. 98433.59
Structure made of 6" x 3" ‘I’-Section Girder, 4" x
2"channels, clamps, nuts, bolts etc. Suitable for
erection of the followings duly connected with
necessary ACSR conductors. as per drawing
approved by the Engineer- in charge complete
with following. Height as per IS 7 Mtr above
(A) 11 KV 200 Amps Drop out fuses with S.R.B.P.
tubes carries.-Three nos
(B) 11 KV G.O.D. switch complete with
insulators, operating handle with galvanised
pipe, Sq.bar etc. 400 Amp.- One Set
(C) 11 KV lightening arrestor with clamp-
(D) 11 KV shackle insulators- Six Nos.
(E) The above D.P. structure should be earthed
with 25 mm.X 3 mm thick double copper earth
strips run separately and connected with
separate copper plate earth electrode.
342 Providing and erecting ISI Marked 3 core 95 350.00 Mtr. 1370.57
Sq.mm XLPE insulated 11 KV armoured cable
Aluminium conductor IS-7098 to be laid on wall
with clamps or in provided cable trench / pipe
approved manner as directed.
343 Providing, and erecting 11 KV Ring Main Unit 1.00 Ea. 479750
(RMU) 1 incoming & 2 outgoing with RMU kit.
Description Qty. Unit Rate Amount
Providing and erecting cable end termination -
kit, heat shrinkable Push on type Densons/
Raychem/ Elastimold make suitable for 11 KV
XLPE cable 3core 95 & 120 Sq.mm
344 (A) Outdoor type 2.00 Ea. 14611.67
345 (B) Indoor type 1.00 Ea. 8004.25
346 Providing, erecting, testing commissioning & 1.00 Ea. 1328836.8
getting Plan Approval as well as NOC from
Electrical Inspector for extensible H.T panel
comprising of one 400A. H.T. VCB incoming &
Two outgoing 400 A Drawout type VCB
confirming as per I.S. for use on 11 KV, 3 phase,
50 c/s. unearthed A.C. supply system having
breaking rupturing capacity of 350 MVA
complete with spring operated mechanism,
mechanically & automatic ON-OFF and spring
mechanism charged, discharged indicators, ON-
OFF mechanical push button, operation counter
necessary auxiliary switches, closing shunt trip,
air insulated busbar chamber having heat
shrinkable PVC sleeves, mechanical interlocks
safety shutters, isolating plugs and a VCB trolley
with three vacuum interrupters with epoxy
support insulators and self aligning finger type
isolating contacts. The breaker shall be Manual
cum motorised mechanism & auto spring charge
with TNC switch closing with following
Description Qty. Unit Rate Amount
1. 144 mm. square flush mounting type digital -
multifunctional meter with communication
facility - Three sets.
2. Power Factor Meter One No
3. Double core current transformer cast resin
type having ratio 200 to 50/1 core for metering
& second core for protection having required
class of accuracy. - Three Sets
4. Instantaneous under voltage relay&
Temperature rise Tripping Relay
5. Electrical closing coil & short trip coil
operating on 110V. D.C.- Three Sets
6. Auxiliary relay for anti pumping device
7. Three phase Three limb Drawout type feeder
connected & output of 200 VA cast resin
insulated potential transformer having ratio
12000V./110V. and 200 VA Burdon with
accuracy. - One No.
8. Common Alarm bell operating on 110V A.C.-
9. Digital KWH Meter - One No.
10. Cable boxes suitable up to 11 KV 3core
sq.mm XLPE cable. - Three Nos
Description Qty. Unit Rate Amount
11. 230V. A.C. to 110V. D.C. power pack for -
closing & tripping circuit common.
12.Breaker ON-OFF, Auto trip and spring
charged indicators. - Three Sets.
13.Phase indicating & panel illumination lamps
with plug socket - Three Sets.
14.Numerical Communicable type non
directional O/C & E/F Relay with
a setting of 5-250% both in O/C & E/F. -Three
complete with necessary interconnection with
air insulated high grade copper busbar {Breaker
Testing scope include Closing Time, Opening
Time, VCB Hi-Pot test at Site}{ Relay Testing
Scope Include testing of all protection by three
phase testing kit at site }(VCB Trolley is to be
347 Providing and fixing printed instruction chart 4.00 Ea. 130.29
both in English and Gujarati and duly framed
with front glasses, for treatment of person
suffering from Electric shock with minimum 50"
diagonally size.
348 Providing pair of rubber hand gloves suitable for 2.00 Ea. 214.12
working on 11 KV/22 KV supply
349 Supplying rubber matting of following thickness 30.00 Sq. Mtr. 3081.51
as per IS:15652/IEC
350 Supplying FIRE bucket round bottom of 9 litres 20.00 Ea. 214.12
capacity made out of 24 gauge G.I. sheet with
extra handle at bottom duly painted white inside
and Red out side with FIRE mark, filled with
dry-sand and kept on existing stand provided or
hung on wall hook.
351 Supplying and erecting floor mounting stand for 5.00 Ea. 942.33
keeping four nos. of FIRE buckets comprising
1500 mm in length, 900 mm height frame made
out of 30mm X30 mm X 4 mm angle iron with
cross supports for legs, welded with 4 hooks and
duly painted with one coat of red lead and two
coats of approved enamelled silver paint.
352 Supplying & fixing Steel Chequered Plate having 30.00 Sq. Mtr. 3531.97
7 mm thickness, duly painted with two coats of
black Japan colour. (Average Wt 61.1 kg /
Description Qty. Unit Rate Amount
353 Providing and erecting XLPE(IS:7098)(I)-88 ISI 180.00 Mtr. 419.15
armoured cable multistrand Copper conductor
for 1.1 KV. to be laid on wall with necessary
clamps or in existing trench / pipe at road
crossing or floor of following size of cables.
(G) 12 core 2.5 sq.mm
354 Lightening protection system for highest 50.00 Kg 808
building at plant area by air terminal with rod
and GI strip conductor test link to earth
electrode as per requirement .
355 Providing and cast in situ C.C. in grade M-20 15.00 cu m. 2424
(approx. corresp. to prop. 1:1.5:3) (proportions
as per mix design or as per table-9 of IS-456-
2000 in masses by weigh batching ) using
quartzite trap metal of size 12 mm to 20 mm and
or 6 mm to 12 mm including scaffolding
centering form work, needle vibrated
consolidation, curing and hydraulic testing etc.
complete with centering and
shuttering/deshuttering etc. complete up to
meter height/depth from Av. G.L. for all
structures with water proofing compound.
(including cost of 35 kg per Cu. M. reinforcement
of CRS steel of all dia Fe500 grade conforming to
- For Foundation, of DG Set and Transformer
356 Providing and erecting Sana Saniya Products 1.00 Lot 2858.3
Fencing Wire 1000 Meter 10kg,/ Boundary Wire
1.5 Mm Silver Plastic Fence Post.
I / We agree to carry out the work at ______________________ % above the estimated tender rates
___________________________________________ should be written in figures and words.
I / We agree to carry out the work at ______________________ % below the estimated tender rates
___________________________________________ should be written in figures and words.
ESTIMATED AMOUNT ESTIMATED AMOUNT
Put to tender Rs. 9,99,93,434.00 Put to tender Rs. 9,99,93,434 .00
Rupees in words : ___________ Rupees in words : _________________
1. (*) Please strike out whichever is not applicable. All work shall be carried out as per the specifications of the GIDC or
2. All the columns in Schedule should be filled in ink and the total entries in the last column should be struck by the
contractor under his signature.
3. Rate quoted included clearance of site (prior to commencement of work & at, its close) in all respect & hold good for
the work under all conditions, site moisture, weather etc.
4. I/We have read the tender/general specifications/ conditions and I/We agree to follow same and binding to me/us.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Bank Guarantee.pdf
Modified schedule.pdf
Volume - I (PQ).pdf
Volume-II (Technical Specification - Civil).pdf
Volume-II (Elec specification).pdf
Price bid.pdf
Schedule C.pdf
B1 Agreement - Part 1.pdf
B1 Agreement - Part 2.pdf
Architech Dwg .pdf
Architech Dwg F.F.pdf
Architech Dwg G.F.pdf
Architech Dwg S.F.pdf
Architech Dwg Terrace.pdf
Cross Section.pdf
Cross Section 2.pdf
Cross Section 3.pdf
Front Elevation.pdf
Side Elevation.pdf
FIRE FLOOR PLAN_VADODARA GIDC (2).pdf
FIRST FLOOR.pdf
GROUND FLOOR (1).pdf
SECOND FLOOR.pdf
Vadodara New Office SLD ALL.pdf
Vadodara New Office SLD FF.pdf
Vadodara New Office SLD GF.pdf
Vadodara New Office SLD SF.pdf
Download all tender documents and submit your bid