Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹9.1 LAdmitted-Finance A 86 MANISH MARG NEMI NAGAR VAISHALI NAGAR JAIPUR JAIPUR JAIPUR RAJASTHAN 302021 | JAIPUR | RAJASTHAN | 302021 | -8.00% | ₹9.1 L | L1 | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
Tender Value
₹11.4 L
EMD Value
₹22,720
Closing Date
15 Apr 2026, 5:00 pmClosed
SE (CIVIL) RRVPN KOTA
SE (CIVIL) RRVPN KOTA
REPLACEMENT OF AIR CONDITIONERS AT 220 KV GSS DOONI (TONK)
2026_RRVPN_550401_3
SE (CIVIL) RRVPN KOTA NITNO32-2025-26
Open Tender
Civil Works
90 days
TONK
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
1180 ACCOUNT OFFICER (T AND C) RRVPN SWM
₹22,720
Yes
24 Apr 2026
7 Apr 2026
16 Apr 2026
7 Apr 2026
15 Apr 2026
7 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply , Installation, Testing and Comissioning of Inverter type Air
Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R- 410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this
BSR .1.5 TR ISEER not less then 4.6(E-22.24.4) | - | Each | - | - |
| 2 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR : 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. (E-4.1.19 ) | - | mtr | - | - |
| 3 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR .25 mm (E-1.4.2 ) | - | mtr | - | - |
| 4 | P&F metal clad / Plastic industrial plug top & socket unit with pin
and sleeve type contact on porcelain/ bakelite base in
Recessed/surface mounting heavy duty Enclosure made out from
Galvanized steel / CRCA sheet not less then 1.2 mm thick
conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted
(without MCB) including making connections, testing etc.as
required.For additional technical parameters of product / work
refer Annexure 'A' attached with this BSR 20 amp, 2 pin + scrapping Earth, 1 Module (E-6.13.1) | - | each | - | - |
| 5 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware /
PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 25.0 Sq. mm3.5 core(E-11.1.5.3) | - | mtr | - | - |
| 6 | Providing & Fixing of Recessed/surface mounting heavy duty
horizontal type Double Door ( Metal / Glazed )Distribution board
with Metal end box made out from Galvanized steel / CRCA sheet
not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC
61439- 1 & 3, powder painted complete with reversible door (for
double door DB only )100 amp. insulated copper bus bar/shorting
link , copper neutral link, copper earth link , color coded
interconnecting wire set of suitable rating and din bar,masking
sheet, making internal DB terminations with copper lugs, Ferrules,
detachable gland plate, including making connections, testing etc.
as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Metal door (Three phase) IK-09 and IP-43 with Metal end box 6 Way ( E 6.10.3.2) | - | Each | - | - |
| 7 | Providing & Fixing of 240/415 V isolator ISI marked IS:13947-
III/conforming to IEC 60947-3, suitable for AC22A utilization
category, 4KV impulse withstand voltage, true contact indication,
Red colour dolly / lever shall have single mould covering over all
poles for operation , two position din rail mounting, minimum
phase termination capacity of 35sq.mm. IP 20 contact protection
and fitted in existing distribution board / sheet including making
connections, testing etc. as required. OEM shall have submit NABL
/ CPRI / ERDA accrediated lab type test reports & All as per pre
approved by Engineer in charge.For additional technical parameters
of product / work refer Annexure 'A' attached with this BSR Four pole Isolator 63 A rating . (E-6.2.3.2) | - | each | - | - |
| 8 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10
kA breaking capacity (B/ C/D tripping characteristic as per type of
load and site requirement) 4 KV impulse withstand voltage, ISI
marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Single pole MCB (With B/C curve tripping Characteristics)6 A to 32 A rating (E 6.1.1.2) | - | each | - | - |
| 9 | Supply, installation, testing and comissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour
barrier and weather protection. Joints shall be covered with nitrile
rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)(E-22.39.11) BSR . | - | mtr | - | - |
| 10 | Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .5 kVA (E- 22.41.3) | - | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.50 MB
Tendernotice_2.pdf
PDF • 32.29 MB
Tendernotice_3.pdf
PDF • 0.07 MB
Tendernotice_4.pdf
PDF • 0.08 MB
Tendernotice_5.pdf
PDF • 0.21 MB
Tendernotice_6.pdf
PDF • 0.11 MB
BOQ_981105.xls
BOQ • 0.25 MB
3BIDDOCUMENTS.pdf
Tender Documents • 1.21 MB
Download all tender documents and submit your bid