Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC VILL GARANIA P O JUKHIA BAZAR P S BHUPATINAGAR DIST PURBA MEDINIPUR PIN 721430 | PURBA MEDINIPUR | WEST BENGAL | 721430 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹6.0 L+₹19,261.62 (3.33%)Rejected-AOC WARD NO 12 TAMLUK PARBATIPUR TAMLUK PURBAMIDNAPUR 721636 | TAMLUK | PURBA MEDINIPUR | WEST BENGAL | 721636 | L2 | Rejected-AOC SECOND LOWEST BIDDER | |
| 3 | L3₹6.1 L+₹29,284.12 (5.06%)Rejected-AOC | L3 | Rejected-AOC THIRD LOWEST BIDDER |
Tender Value
₹5.8 L
EMD Value
₹11,585
Closing Date
10 Mar 2025, 6:00 pmClosed
Divisional Manager, Contai Division
Contai Division, WBSEDCL, Manoharchak, Contai
Construction of new 33 KV PTR Bay for installation of one new 6.3 MVA PTR at Malda 33/11 kV Sub-station under Contai Division.
2025_WBSED_817195_1
WBSEDCL/CD/E-TENDER/2024-25/16 Date 18.02.2025
Open Tender
Miscellaneous Services
Item Rate
Contai Division, WBSEDCL, Manoharchak, Contai
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹11,585
22 Apr 2025
21 Feb 2025
13 Mar 2025
21 Feb 2025
10 Mar 2025
21 Feb 2025
Amount
Erection of 4 pole Isolator Support structure with fittings on 8mtr PCC with foundation
Erection of H/L isolator (without E/S )strucure with supply of Nuts and bolts on existing 4 pole structure
Erection of 2 pole structure withing fittings and foundation with provision for L.A with foundation along with supply of all Nuts & Bolts * L.A Base Plate 430x430x8 mm (L.S) (as per site authority)
Erection of L/L isolator w/o E.S strucure with supply of Nuts and bolts on new PCC 4 pole structure
Erection of CT structure along with supply of fabricated GI
Erection of cable supporting structure along with supply of Fabricated GI
Erection of 33kv VCB ,SCADA compatible O/D type
Erection of 33kv, C&R panel , SCADA compatible for individual control of power transformer with diferential relay with necessary connectionwith directional Relay
Erection of 33 kv CT , 200-100/1-1-1 Amp CT's for Power Transformer with supply of CT Junction Box
Laying and jointing of 1.1 kv 4C*2.5 sq mm copper control cable with supply of cable lugs,glands , tapes, sockets etc
Laying and jointing of 1.1 kv 8C*2.5 sq mm copper control cable with supply of cable lugs,glands , tapes, sockets etc
Laying and jointing of 1.1 kv 12C*2.5 sq mm copper control cable with supply of cable lugs,glands , tapes, sockets etc
Erection of 42 kv class gapless lightning arrestor along with installation of LA support Structure
Laying of 11 kv 3*300 sq mm XLPE cable
Fixing of 12 kv gapless LA(3 nos=1set) along with installation of LA support Structure
Erection of 11 kv ,800 A,350 MVA ,5 panel shunt trip switchgear with VCB , SCADA compatible (1 IN +1 BC+2 OUT+1BA)
installation of RTCC panel for 6.3 MVA, 33/11 KV power transforme
Erection of ACSR 200 sq mm (PANTHER) conductor 3 wire including laying , hoisting , jointing etc
Making of Compression Joint for ACSR Panther Condutctor including supply of all required connectors & accessiories etc.
Fixing of 33 kv pin insulator
Erection of 33 kv Disc insulator
Supply of Bimetallic Connector for Power Transformer including Labour charges for fixing
Supply of Panther to Panther Tee Connector including Labour charges for fixing
Supply of GI Flat 65x6MM for earthing of all new structures, installed equipment, PTR's body & neutral,CT, VCB,PT, LA, 11 kVSwitchgear etc. including labour charges & Supply of 40mm GI Pipe(3 mtr length) for earth pit for new structures, PTR etc. including labour
MAHAKALI ENGINEERING WORKS (BID ID -6215930)
ACAM CONSTRUCTION (BID ID -6215948)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .