Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC | L1 | Accepted-AOC DUE TO L1 | |
| 2 | surinder kumar jindal bros L2₹30.2 L+₹51,780.40 (1.74%)Rejected-AOC | L2 | Rejected-AOC DUE TO L2 | |
| 3 | L3₹30.5 L+₹73,888.74 (2.49%)Rejected-AOC | L3 | Rejected-AOC DUE TO L3 | |
| 4 | L4₹31.2 L+₹1.4 L (4.82%)Rejected-AOC | L4 | Rejected-AOC DUE TO L4 | |
| 5 | L5₹31.7 L+₹2.0 L (6.70%)Rejected-AOC | L5 | Rejected-AOC DUE TO L5 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
20 Jan 2020, 6:00 pmClosed
CWE YOL CANTT
HQ CWE YOL CANTT
SPECIAL REPAIR TO BLDG NO P-192 AND BLDG NO P-141 (OR MD ACCN) ATBHARATPUR LINE AND RETAINING WALL AROUND THE UG SUMP OF 50000 GLNS CLOUD END WATER TANK PREMISES AT MIL STN DHARAMSALA
2019_MES_295966_1
CWE/Y-55/2019-20
Open Tender
Civil Works
Works
180 days
DHARAMSALA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) DHARAMSALA
₹66,000
Yes
6 Feb 2020
27 Dec 2019
21 Jan 2020
27 Dec 2019
20 Jan 2020
8 Jan 2020
Amount
Schedule "A" Part-I:- Rough excavation in any type of soil not exceeding 1.50 metres deep and getting out in all as specified & directed.
Excavation over areas in any type of soil not exceeding 1.50 metres deep and getting out in all as specified & directed.
Excavation in trenches for pipes, laying of cables and manholes in any type of soil n.exc 1.5m wide and but exc 1.5m deep and getting out complete all as specified and directed.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specified and directed.
Removal of excavated material (soil) to a distance n.exc 50 metres and depositing where directed at a level n.exc 1.5 metres above the starting point complete all as specified and directed.
Removal of excavated material (soil) to a distance exc 50 metres but not exceeding 250 metres and depositing where directed at a level n.exc 1.5 metres above the starting point complete all as specified and directed.
Taking down chowkhats or frames n.exc 1.50 sqm with shutters (without taking off shutters from the frames) all as specified & directed.
Taking down shutters of any description exc. 1 Sqm but not exc. 2 Sqm each, all as specified.
Taking down shutters of any description exc. 2 Sqm each, all as specified.
Plain cement concrete, M-10, nominal mix, C-2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete, as in sub base layer under floors, all as specified and directed.
Reinforced cement concrete (Design mix) M-30 (using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, all as specified.
Reinforced cement concrete (Design mix) M-30 using 20mm graded stone aggregate as in in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including necessary form work) complete all as specified and directed. Note for Serial Item No 11 & 12:- Form work and reinforcement if any shall be measured and paid separately.
TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Wire netting of galvanised steel wire 1.40mm dia with size of wire mesh 12 mm as in gravel block behind wheep hole fixed with tinned tacks of wire staples all as specified and directed.
110 mm bore PVC (SWR) pipes single socketed in any length having pressure rating 4 Kg/ sqcm as in weep holes complete, all as specified.
Hand packing (any thickness) broken stone or boulders at back of walls over arches etc. and raising (or lowering) to the required level, all as specified.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for roughly finished flat surfaces of concrete, all as specified and directed.
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, for roughly finished flat surfaces of concrete all as specified and directed.
Factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain coloured PVC sheet and edges shall be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing on page No 160 of MES SSR 2010 Part-II
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of 5 mm thick plain coloured PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site, Sheet No 1/1) specified and directed.
Pressed steel frames for doors of size 125 mm X 60 X 1.25 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed including one shop coat of red oxide zinc chrome primer and filling frame with PCC m-15, type B-0 using 12.5 mm graded crushed stone aggregate, all as specified and directed.
Factory made 2nd class hard wood (Sal/ Hollock) plain, framed, panelled 35mm thick shutters (two panels) with lock rail and panels of 9mm BWP commercial plywood or 12mm veneered particle with commercial face veneers on both sides. The size of rail and style as per IS–1003 (Part-I), kiln seasoned and chemically pressure treated, all as specified.
Factory made 30 mm thick second class hard wood (Sal) glazed and skelton door shutters open rebated and prepared to receive glass gauge etc (with out sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass or gauge etc., size of members of shutter as specified in clause 8.24 (a) of part-I, fitted to chowkats, complete all as specified.
Factory made 2nd class soft wood (Kail) plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pined at joint complete all as specified .
Factory made 30 mm thick second class hard wood (Sal) glazed and skelton door shutters open rebated and prepared to receive glass gauge etc divided into squares with plain, chamfered or rounded, mitred and rebated sash bars, any numbers with edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass or gauge etc., as in windows, ventilators, etc. are provided with stiles and rails as specified in SSR Part I, Section 8 clause 8.24(b) of part-I, fitted to chowkats, complete all as specified.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks of galvanised wire staple fixed with stainless steel wire staples all as specified and directed.
Aluminium anodised, barrel tower bolts of size 150mm extruded section and fixed all as specified & directed.
Aluminium anodised, barrel tower bolts of size 100 mm extruded section and fixed all as specified & directed.
Butt hinges, medium weight, cold rolled, mild steel 100mm complete all as specified and directed.
Butt hinges, medium weight, cold rolled, mild steel 75mm complete all as specified and directed.
Aluminum alloy handle, cast type anodised of size 150 mm complete all as specified and directed.
Aluminum alloy handle, cast type anodised of size 100 mm complete all as specified and directed.
Mild steel sliding door bolt, bolt type, stove enamelled black, with bright bolt not less 12mm dia, with and including a minimum of 6 bolts and nuts, 4 on bolt plate and 2 on stapple plate, 300mm long, all as specified.
Hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws of size 100 mm, all as specified.
12mm thick plywood, grade BWR, type BB, one side teak face, fixed with screws to timber frame work as in cupboard door, complete all as specified & directed.
Steel door with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded etc., complete all as specified, supplied and fixed including one shop coat of red oxide zinc chrome primer, all as specified.
Steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded etc., complete, as specified, supplied and fixed including one shop coat of red oxide zinc chrome primer, all as specified. Note for Serial Item No 36 & 37:- Weight of steel doors/ windows shall be ascertained by BOO to be convened by GE/ AGE (I).
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads all as specified.
3 mm thick sheet glass, ordinary quality and glazing with oil putty/ wooden beads in square pane not exc 0.50 Sqm each pane in wooden/ Steel windows complete all as specified and directed.
Painting two coats with synthetic enamelled paint over a coat of red oxide zinc chrome primer on new steel or iron surfaces of any description exceeding 10cm width/ girth including preparation of surfaces over a coat of red oxide primer all as specified and directed.
Painting two coats with synthetic enamelled paint on old steel or iron surfaces of any description exceeding 10cm width/ girth including preparation of surfaces all as specified and directed.
Applying two coats of synthetic enamel paint over a coat of pink primer on new wood or wood based surfaces of any description, exc. 10cm width or girth including preparation of surfaces, all as specified.
Applying two coats of synthetic enamel paint on old wood or wood based surfaces of any description, exc. 10cm width or girth including preparation of surfaces, all as specified.
Easing of steel windows (glazed and guazed) including welding etc complete all as specified and directed.
Mild steel peg stay for steel windows complete all as specified and directed.
Mild steel handle for steel windows complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified.
Rendering cement plaster 10 mm thick on fair faces of brick/ concrete surface in cement mortar 1:6 (1 cement : 6 coarse sand) and finished even and smooth without using extra cement complete all as specified.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and directed.
Prepration of old treated surfaces of walls by removing existing treatment by scarping, brushing etc including making surface clean , dry and free from any loose paint film, dirt, chalk, grease, fungus and algae and filling holes, dents, cracks with mixture of white cement and mortar for applying two coats of oil bound distemper over a coat of chalk whiting, complete all as specified and directed.
Prepration of old treated surfaces of ceiling by removing existing treatment by scarping, brushing etc including making surface clean, dry and free from any loose paint film, dirt, chalk, grease, fungus and algae and filling holes, dents, cracks with mixture of white cement and mortar for applying two coats of oil bound distemper over a coat of chalk whiting, complete all as specified and directed.
Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer), mixed with liquid water proofing compound as per manufacturer's instructions on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. ( Note : WPC will be measured and paid separately under respective Item of BOQ)
Supply only liquid water proofing compound, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of exterior emulsion (Apex ultima protect of make "Asian" or equivalent in makes mentioned in appendix 'C') over a coat of primer of same brand/ make as of exterior emulsion complete all as specified and directed.
Preparation of old or previously treated plastered or unplastered surfaces of walls including complete removal of existing treatment and applying two coats of exterior emulsion (Apex ultima protect of make "Asian" or equivalent in makes mentioned in appendix 'C') over a coat of primer of same brand/ make as of exterior emulsion complete all as specified and directed.
5mm thick rendering in cement mortar 1:4 (1 cement : 4 coarse sand) on concrete surfaces of ceiling, surface finished even and smooth without using extra cement, complete all as specified.
Preparation of new plastered or unplastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
25mm thick cement concrete M-15 (Nominal mix) type B-0 (using 12.5mm graded crushed stone agg ) as in flooring, finished even & rough to receive floor finishes complete all as specified and directed.
Plain cement concrete M-10, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved).
Mat finish, premium quality, non skid, coloured/ printed ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed.
Mat finish, premium quality, non skid, coloured/ printed ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed.
Machine cut kota stone slab flooring 20-25 mm thick of size not less than 550 mm X 550 mm as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 15 mm screed layer in cement mortar 1:6 (1 cement : 6 coarse sand), cutting, rubbing, grinding and polishing to achieve mirror finish, laid over PCC subbase complete, all as specified. Note:- PCC sub base if provided, shall be measured and paid under respective Items of BOQ.
Machine cut kota stone slab 15-20 mm thick as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab as in in skirting, dados, risers to steps etc, laid over and including 10 mm screed layer in cement mortar 1:4 (1 cement : 4 coarse sand), cutting, rubbing, grinding and polishing to achieve mirror finish complete, all as specified.
Dismantling stone slabs and tiles of any description or thickness including screed bed as in vertical surfaces complete all as specified and directed.
Glazed ceramic, premium quality, coloured/ printed tiles 450mm x 350mm x 7 to 8 mm thick on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed.
20mm thick granite (of any type) work (table rubbed and polished) as in steps, floors, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding and polishing complete laid over and including 15 mm thick screed bed in cement mortor (1:6) (1 cement : 6 coarse sand) laid and jointed with gray cement slurry mixed with pigment, complete all specified.
Sink made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 405mm x 355mm x 178 mm, fixed in repairs all as specified. Make:- (Cat Part No BSSB-06A of make 'Blue Star or equivalent in makes mentioned in Appendix 'C').
PVC valve less, crystal white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long and 15 mm dia 600 mm long PVC connection with CP brass coupling nuts and PVC washers at both ends fixed, in repairs, all as specified. Make: Cat Part No. 2602 of Cera or equivalent in makes mentioned in Appx 'C'.
Vitreous Chinaware squatting pan, ‘Orrisa pattern’ size 580 mm x 440 mm,( excluding flushing cistern and flushpipe) crystal white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, integral foot rest with provision of plain cement concrete M-15, type B-I using 20 mm graded crushed stone aggregate complete all as specified, incl making connections to trap and to flush pipe, etc and making good to floors to match existing, in repairs, all as specified. Make: Cat Part No. 2071 of 'Cera' or equivalent makes mentioned in Appx 'C'
Taking down existing unserviceable roof treatment materials and PCC/ cement mortar padding etc complete from roof carefully by cutting chiselling, cleaning the surface by scrapping, brooming, brushing etc and removing the rubbish from site complete, all as directed by Engr-in Charge.
10mm thick (average) screed bed/ plaster in cement mortar 1:3 (1 cement : 3 coarse sand) in order to maintain proper slope and base over existing roof surface for laying of APP based polymeric membrane, mixed with liquid water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete, all as specified and directed. (Note:- WPC and polymeric membrane shall be measured and paid separately)
Applying a coat of cement slurry @ 3 kg/ sqm including preparation of surfaces, complete all as specified and directed.
Applying a coat of bitumen primer conforming to IS: 3384-1986 over plastered surfaces @ 0.40 litres/ Sqm of density 087-0.89kg/ litres at 25° C and viscosity 70-160CPS (Bitumen primer shall be of same make as of memebrane) including preparation of surfaces, complete all as specified & directed.
APP (Atactic Poly-propylene polymer) modified membranes, five layered, 3mm thick weighing not less than 3.6 kg/ Sqm, having a centre core of polyester non-woven mat (FP) reinforcement dipped into APP modified mix and sealing all the over laps 75mm on length side and 100mm on width side of membranes by torching as per manufacture's instructions by authorised applicator only after applying evenly a coat of bitumen VG-10 grade @ 1.2kg per sqm on the bottom of APP and on top of joints of APP complete all as specified.
Disconnecting water tanks, setting aside and re hosting refixing in position after carry out roof repair including making connections of capacity 500 litres, complete all as specified.
Taking down water tank exc 250 litres but not exc 500 litres capacity and removing to store, complete all as specified.
Rotational moulded polyethylene water storage tank 500 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valce, high pressure with PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line including taking down of old tank, all as specified.
Plain cement concrete M-7.5, nominal mix, D-2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete, as in sub base layer under floors, all as specified. Note:- Unit rate quoted shall deemed to be included cost of necessary form work.
Chequered cement concrete tiles machine pressed of size 30cmx 30cmx 30mm thick with grey cement, set jointed & pointed in neat cement slurry mixed with pigment to match the shade of the slab in floors laid over and including 15mm thick screed bed in cement mortar 1:6 (1 cement : 6 coarse sand) complete, all as specified. Note:- PCC sub base if provided shall be measured and paid under Srl Item No. 80 above. Thickness of sub base shall be 50 mm.
Taking up or down steel tubing 15mm dia and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down steel tubing 20mm dia and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Mild steel galvanised iron tubings (ISI Marked) 15mm dia medium grade with all fittings & fixtures complete to walls/ ceilings or laid in floors all as specified and directed.
Mild steel galvanised iron tubings (ISI Marked) 15mm dia medium grade with all fittings & fixtures but "except GI tubing" complete to walls/ ceilings or laid in floors all as specified and directed. Note:- Servicable GI tubing retreived from taking down under respective Items of BOQ shall be reused.
Mild steel galvanised iron tubings (ISI Marked) 20mm dia medium grade with all fittings & fixtures complete to walls/ ceilings or laid in floors all as specified and directed.
Mild steel galvanised iron tubings (ISI Marked) 20mm dia medium grade with all fittings & fixtures but "except GI tubing" complete to walls/ ceilings or laid in floors all as specified and directed. Note:- Servicable GI tubing retreived from taking down under respective Items of BOQ shall be reused.
Bib taps, 15mm bore, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down high pressure, screwed for iron pipe or for brass ferrule fixed in repairs, all as specified.
Stop valves/ angle valves, cast copper alloy, chromium plated, fancy type, screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15 mm bore iron pipe or for unions and fixed in repairs complete, all as specified. (Makes mentioned in Appendix 'C').
Chromium plated brass shower rose, fancy type, 125mm size with shower arm, chromium plated, 195mm long with bend of 45° with flange suitable for 15mm bore pipe with swivel joint fixed to pipe in repairs, complete all as specified.
Tubular towel rail, Brass, Chromium plated, 20mm dia, D type, 60cm long between flanges, all as specified.
Demolition of cast iron or reinforced concrete drain pipes jointed in cement mortor and taking out of trenches, complete all as specified and directed.
Cast iron floor trap with oval access door having dia of outlet 75 mm with grating including jointing to waste pipe fixed in cement concrete type B-1, M-15 complete all as specified.
Cast iron soil, waste and vent pipe, sand cast, 100 mm bore in any length with or without ears with cement joints, laid in trenches or in floors, complete all as specified.
Cast iron soil, waste and vent pipe, sand cast, 100 mm bore in any length with or without ears with cement joints, but fixed in walls, complete all as specified.
Cast iron soil, waste and vent pipe, sand cast, 75 mm bore in any length with or without ears with cement joints, laid in trenches or in floors, complete all as specified.
Cast iron soil, waste and vent pipe, sand cast, 75 mm bore in any length with or without ears with cement joints, but fixed in walls, complete all as specified.
Cast iron soil, waste and vent pipe, sand cast, 50 mm bore in any length with or without ears with cement joints, but fixed in walls, complete all as specified.
Cast iron cowl of 50mm bore, complete all as specified.
Cast iron ‘P’ or ‘S’ trap, bore of pipe 100mm, complete all as specified.
Cast iron floor trap with oval access door having dia of outlet 100 mm with grating including jointing to waste pipe fixed in cement concrete type B-1, M-15 complete all as specified.
Cast iron bends (any radius), diminishing pieces or tapers (larger bore measured), 75mm bore, complete all as specified.
Cast iron bends (any radius), diminishing pieces or tapers (larger bore measured), 100mm bore, complete all as specified.
Cast iron branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, 75mm bore, complete all as specified.
Cast iron branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, 100mm bore, complete all as specified.
Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for bore of pipe 75mm/ 100mm, all as specified.
Plain cement concrete M-15, nominal mix, B-I using 20mm graded mechanically crushed stone aggregate as, in lintels upto 1.50 metres clear span, steps, seismic and other similar bends, coping, bands plates for serving hold fasts, filling in mild steel frames etc. and the like including weathering slighting rounded or chamfered angles and throating complete all as specified. Note:- (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately.
Dismantling plain or corrugated steel sheeting any guage, thickness including Nainital or similar pattern roof covering, all as specified.
Corrugated galvanised iron mild steel sheets 0.63mm thick, grade ‘O’, with 120 grams per square metre zinc coating fixed with 'J' or 'L' hook as in roof covering with two corrugation side lap. (Horizontal distance of side lap shall not be less than 145mm and depth of corrugation shall be 12.5mm), all as specified.
Plain galvanised iron mild steel sheets 0.80mm thick, grade ‘O’, with 120 grams per square metre zinc coating as in ridges, valley, gutter etc. Fixed with 'J' or 'L' hooks, all as specified.
Taking down roof trusses, coupled rafters or trussed beams for renewal of any defective members, housing and refixing trusses etc after repair including tightening up wedges, cotters bolts etc having clear span above 4 metres, complete all as specified. Note:- Defective members shall be measured and paid separately under respective Items of BOQ.
Dismantling timber scantling 40 Sqcm and over in section, in any position (unframed work), complete all as specified.
2nd class soft wood (Kail) wrought timber frame work as in replacement of defective members of trusses, purlins etc, complete all as specified.
2nd class soft wood wrought timber frame work as in replacement of defective members of trusses, purlins etc, but except timber complete all as specified. Note:- Servicable timber retreived from dismantling shall be reused.
Dismantling wrought iron or mild steel work of any description not otherwise provided for any work, complete all as specified.
Mild steel work as in wind ties, doors hold fast etc including necessary drilling bolting or rivting and similar work confirming to FE 290 Gde E-165), all as specified.
Preparing surfaces of wood and wood based material new or old of any description and girth not otherwise described and treated with two coats of cresote oil, complete all as specified.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness including cover fillets in ceiling, all as specified.
4mm thick non-asbestos fibre cement building board as in ceiling, ISI marked, fixed or laid/ inserted to timber/ GI/ Aluminium frame work with screws, complete all as specied
Two coats of white wash on newly plastered or unplasterd,asbestos/non asbestos surfaces of ceiling including preparation of surfaces complete, all as specified.
Demolition of stone or brick masonry built in cement mortar including all quoins, arches etc. but excluding ashlar facing, dressed stone work etc, complete all as specified.
Walling random rubble masonry with best quality locally available stone, uncoursed, well bonded, bedded, solidly hearted and built in cement mortar 1:6 (1 cement : 6 coarse sand), all as specified. Note: Locally available slate stone shall not be used.
All as per srl item No 35 above but except stones. Note:- Servicable stones retreived from demolition under respective Items of BOQ shall be reused.
Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 (01 cement : 06 coarse sand) all as specified & directed.
Dismantling timber scantling in rails, posts, fillets, rafters, purlins etc. under 40 sqcm in section, in unframed work, complete all as specified.
2nd class soft wood (Kail) as in plain fillets, square, rectangular or triangular in section, clean sawn, sectional area exc. 6 Sqcm but not exc. 13 Sqcm, fixed with nails, all as specified.
Prepration of new wooden or wood based surfaces of any description n exc 10cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified.
Schedule "A" Part-II:- Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator (any type) is to be refixed and connected properly where required.
Point wiring with 1.5 Sqmm copper conductor FRLS (Multistrand) PVC insulated ISI Marked unsheathed cable in and including PVC casing and caping of approved size, double lock type, medium grade, ISI marked with all fittings/ accessories as specified in preamble 1 (a) to (q) of Section 19 of SSR Part-II, under heading point wiring and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as earth wire (green colour) connected to common earth dolly for modular fitting and including modular box sunk for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet (Make Hylum or equivalent ISI marked) for one light point or one fan point through regulator or one bell point, controlled by one way switch/ push button complete including making good disturbed surfaces to match with existing all as specified and directed.
All as per serial item No '129' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed.
All as per serial item No '129' above, but for one 3 pin 5 Amps socket outlet, independent board all as specified and directed.
All as per serial item No. '129' above but for 3 pin 15 Amps socket out let independent with 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
Socket outlet two & three pin 5Amp flush type, all as specified.
Socket outlet two in one, 3 Pin, 5 amps and 15 amps, flush type, all as specified.
Switch piano flush type, single pole, one way, 15 Amps, all as specified.
Switch piano flush type, single pole, one way, 5 Amps, all as specified.
Bell push switch, flush type, single pole, 5 Amps, one way, all as specified and directed.
Electric bell, Ding Dong AC, 230 volts, single pole, all as specified and directed.
Sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded RLS conductor of size 6 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 4 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :- Two run (each run of 1 RM) of 6 sqmm copper conductor and one RM of earth wire of 4 Sqmm, shall be measured as one RM).
Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified.
Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 12 way, double door, 240 volts with 200 Amp rated bus bar, all as specified. Make : Havells Cat Part No. DHDPSHODPW12 or equivalent in makes mentioned in Appx 'C'.
MCB SPN 40 Amp, 240 Volts, 10 kA all as specified. Make : IndoAsian Cat Part No. 811153/ 811154 or equivalent makes mentioned in Appx 'C'.
MCB SP 6 to 32 Amp, 240 Volts, 10 kA all as specified. Make : Havell's Cat Part No. DHMCCSPF006-032 or equivalent makes mentioned in Appx 'C'.
Batten for LED tube suitable for indoor applications tube light fitting 4 FT, 1x18 watt complete all as specified. Make- Havells cat part no. REGALBATTEN5UPTO1X18WDBSWH or equivalent makes mentioned in Appx 'C'.
Led tube light with very high efficiency suitable for installation in existing batten complete all as specified. Make- Havells cat part no. CRYSTAL1213T8DSTL18WLED865S-GLASS or equivalent makes mentioned in Appx 'C'.
Energy efficient LED integrated batten suitable for indoor applications tube light fitting 1X10 watt 2 FT complete all as specified. Make- Havells cat part no. LUMILINEPLUSBS10WLED865SPCSS or equivalent makes mentioned in Appx 'C'.
1X25 Watts, LED street light fitting with lamp, pressure die cast housing with epoxy powder coated dark graphite grey colour finish, prismatic polycarbonate cover with individual LED lenses with GI pipe 1.50 metres long, clamps, nuts, bolts complete with all acessoreis prewired and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete. Make : Crompton Cat Part No LSTS 25CDI LED or equivalent makes mentioned in Appx 'C'.
Lamp holder, PVC/ Polycarbonate type with back plate suitable for angular/ batten fittings, all as specified.
7 Watt Led lamp pin type complete all as specified . Make-Polycab cat part no.LLP0101029 AELIUS LX LED LAMP 7 W BC 6500 K or equivalent makes mentioned in Appx 'C'.
Taking down electric meter of any capacity and re-fixing the same and connecting electrically with the circuit, complete all as specified & directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick cover of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete and taking out old unservicable cable all as specified. Note:- Excavation & Earth work, cable cover, GI tubing and sand cushioning shall be measured and paid separetly.
Sand cushioning to Underground Cables complete all as specified in clause 19.75 of SSR Part-I laid before and after laying of cablesall as specified and directed. (Note:-Punned thickness of sand shall be measured for payment).
Sub class "B" bricks for covering to cable laid dry flat, with width equal to length of bricks all as specified and directed.
GI pipe light grade of size 40 mm dia laid in trenches / walls including clamps, screws etc, complete all as specified and directed.
Sheet metal enclosures for DBs when MCBs to be used, triple pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar, all as specified. Make : Havells Cat Part No. DHDPSHODPW8 or equivalent in makes mentioned in Appx 'C'.
MCB TPN 40 to 63 Amp, 415 Volts, 10 kA all as specified. Make : Indoasian Cat Part No. 811359 or equivalent makes mentioned in Appx 'C'.
surinder kumar jindal bros
vivek and co
Mahashakti Enterprises
jatindera enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .