Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹18.2 L+₹3.5 L (24.2%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-Finance Not a Lowest Bidder | |
| 3 | L3₹19.5 L+₹4.9 L (33.5%)Rejected-Finance | L3 | Rejected-Finance Not a Lowest Bidder | |
| 4 | L4₹22.5 L+₹7.9 L (54.2%)Rejected-Finance | L4 | Rejected-Finance Not a Lowest Bidder | |
| 5 | L5₹23.3 L+₹8.7 L (59.8%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | L5 | Rejected-Finance Not a Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
31 May 2021, 6:00 pmClosed
GE (AF) CHILODA
VAYU SHAKTI NAGAR CHILODA- 382042
COMPREHENSIVE DAY TO DAY REPAIR AND MAINT OF INTERNAL ELECTRIFICATION SERVICES FOR MD ACCN INCL MAP BLDG AT VSN AF STN CHILODA
2021_MES_440236_1
8910
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Chiloda
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (AF) CHILODA
₹50,000
Yes
7 Aug 2021
4 May 2021
3 Jun 2021
4 May 2021
31 May 2021
18 May 2021
Amount
Taking down carefully copper/ aluminum point wiring (Light, fan, socket, power and Bell) including fixture and fittings such as switches, sockets, ceiling roses, lamp, holder , regulators, sockets light fittings etc, removing material to store for keeping in safe custody or for taking credit, and making good disturbed surface of walls, floors, etc. complete all as specified and directed by Eng-In-Charge.
M&L for point wiring in repair for modular accessories with modular metal flush box and cover plate with frame of suitable size complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through metallic rigid/ PVC heavy duty concealed conduit/ casing capping/open coduit with 1.5 sqmm, single core, PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade as earth continuity wire terminated in new modular sunken boxes and modular metal flush box as required size at site incl all connected accessories, box made from not less than 1.6mm GI sheet factory made complete all as specified and directed by Eng-In-Charge for the following:-
One light point controlled by one switch complete.
One fan point controlled by one switch complete.
One 3 pin socket out let 5 Amps on the independent board.
One 3 Pin socket out let 5 Amps on the same board.
One bell point controlled by one switch.
All as per Item No. 2 above but with cable of size 2.5 Sq mm PVC insulated on independent board for power plug 15 Amps.complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Modular switch one way 6A,1 Module, complete all as specified and directed by Eng-In-Charge.
S&F in repair/replacement Modular switch one way 16A, 1 Module, complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Modular bell push 6A,1 Module, complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Modular socket 6/10A-2/3 pin combined, 2 Module complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Modular socket 16/15A-2/3 pin combined, 2 Module complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Modular switch craptree type ,one way 6A, 1 Module, complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Modular switch craptree type, one way 16A,1 Module, complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Modular bell push craptree type 6A,1 Module, complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Modular socket craptree type, 6/10A-2/3 pin combined, 2 Module complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Modular socket craptree type, 16/ 15A-2/3 pin combined, 2 Module complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement switch Roma modular 01 way, 06 Amps, 240 volts complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement switch Roma modular 01 way 16 Amps, 240 volts complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Roma modualr socket 02 module 06 Amps, 240 volts complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Roma modular socket 02 module, 16 Amps, 240 Volts complete all as specified and directed by Eng-In-Charge.
M&L for point wiring in repair/ replacement with 1.5 Sqmm single core PVC insulated unsheathed multi stranded copper conductor FRLS cable 1100V grade drawn through and incl PVC casing in capping/ conduit with accessories like bends tees, junction boxes etc fixed recessed in wall or ceiling etc including 1.5 Sqmm single core PVC insulated but unsheathed multistrandard copper conductor FRLS cable 1100V grade as earth continuity wire incl sunken type pressed steel terminal boxes of size with 3mm thick bakelite steel white/coloured top cover for complete all as specified and directed by Eng-In-Charge:-
One light point controlled by one switch.
One light point controlled by two, two way switches.
One fan point controlled by one switch.
One bell point controlled by one switch.
One 3 Pin socket out let 5 Amps on the same board.
One 3 pin socket out let 5 Amps on the independent board.
All as per Item No 18 above but 2.5 sq mm wire for 15 amps power plug point complete all as specified and directed by Eng-In-Charge..
S&F in repair/ replacement switch piano type 230 volts , 5 Amps, single pole complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Socket out let 2 in 1, 3 pin, 5 Amps flush type 230 volts complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement switch socket combined universal 2 in 1, 6 pin, 5/15 Amps. complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement switch socket combined universal 2 in 1, 6 pin, 5 Amps complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement switch socket combined universal 2 in 1, 6 pin, 5/15 Amps. Box type complete all as specified and directed by Eng-In-Charge.
S&F switch in repair/ replacement flush type, 5 Amp single pole 2 way complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement bell push 5 Amps flush type complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Ding dong bell AC 230V complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement coard less bell of different music AC, 230 V complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement ceiling rose 3 terminal/ poly carbonate, isolated body complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Lamp holder, insulated body with back plate for battern fitting complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement angle holder, insulated body with back plate for battern fitting complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement 3 pin plug top 6A, 240 V complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement 3 pin plug top 16A, 240 V complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement white cover plate with frame, 1 module complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement white cover plate with frame, 2 module complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement white cover plate with frame, 3 module complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement white cover plate with frame, 4 module complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement white cover plate with frame, 6 module complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement white cover plate with frame, 8 module complete all as specified and directed by Eng-In-Charge.
M&L for Sub main wiring in repair/ replacement complete with two run of 6 Sqmm single core, PVC insulated but unsheathed, multistranded copper conductor FRLS 1100 Volts grade cable drawn through in and including non metallic, rigid, PVC heavy duty surface conduit/casing capping (ISI marked) with wall thickness not less than 1.8mm complete with all accessories like bends, tees, junction boxes fixed on wall, ceiling and incl sunken type pressed steel terminal boxes with 3mm thick bakelite white/coloured (as approved) top cover including 6 Sqmm single core PVC insulated but unsheathed multistandard copper conductor FRLS 1100 Volts grade cable as earth continuity wire and connected to earth dolly complete all as specified and directed by Eng-In-Charge. Note:- Two run of 6 Sqmm cable incl one run of earth wire and PVC conduit and its accessories shall be measured and paid as one length.
M&L in repair/ replacement of sub main wiring complete with PVC insulated cable of single core 4.0 Sqmm (FRLS) 1100 volts grade with multi stranded copper conductor for drawn through and including PVC casing-capping with accessories incl 4.0 Sqmm unsheathed multi stranded copper conductor as on earth wire complete all as specified and directed by Eng-In-Charge. Note:- Two run of 6 Sqmm cable incl one run of earth wire including PVC casing-capping and its accessories will be measured and paid as one unit.
S&F in repair/ replacement PVC insulated insheathed multi stranded copper conductor single core of capacity 1.5 sq mm FRLS cable complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement PVC insulated insheathed multi stranded copper conductor single core of capacity 2.5 sq mm FRLS cable. complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement casing-capping patti suitable for 3 core/ 1.5 Sqmm/ 2.5 Sqmm wire complete all as specified and directed by Eng-In-Charge.
Taking down old unserviceable sheet metal enclosure and Supply and fixing sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links (without MCB's) 4 ways TPN complete all as directed by Engineer-in-Charge.
Supply and fixing in repair/ replacement sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links (without MCB's) 12 ways SPN complete all as directed by Engineer-in-Charge.
All as per Item No 46 above but 8 way.
All as per Item No 46 above but 4 way.
All as per Item No 46 above but 2 way single door.
Taking down old unserviceable sheet metal enclosure and Supply and fixing factory made single pole and neutral sheet metal enclosure with a two Pin Socket plug and socket with one single pole MCB 240Volts, 20 Amps, capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair/ replacement factory made three phase sheet metal enclosure with a Three Pin Socket plug and socket with one three pole MCB 415 Volts, 40 Amps, capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair/ replacement MCB, TPN 240 volts, 63 Amps capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair/ replacement MCB, SPN 240 volts, 40 Amps capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair/ replacement MCB, SPN 240 volts, 5-32 Amps capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair/ replacement MCB, single pole 240 volts capacity 5 Amps to 32 Amps current rating, 10KA breaking capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair/ replacement blanking plate complete all as specified and directed by Engineer-in-Charge
S&F in repair/ replacement residual current circuit breaker (RCCB)/ ELCB of DP of capacity 63 Amps and as directed by Engr In charge.
S&F in repair/ replacement residual current circuit breaker (RCCB)/ ELCB of DP of capacity 32 Amps and as directed by Engr In charge.
S&F in repair/ replacement Isolator 4 pole 63 Amps 415 volts 50 Hz complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement isoator 4 pole 100 Amps 415 volts 50 Hz complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement for LED tube light fittings 1x22Watts, single side connection 230 volts surface and wall mounted LED type, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories internally pre wired and including connection up with twin core twisted flexible copper conductior cable of size 1.5 sqmm complete all as specified and directed by Eng-In-Charge. Make:- Havells cat No. ENDURALINEARNEOBS22WLED865SPCWH or equivalent make as approved by GE.
S&F in repair/ replacement for LED light fittings 1x9Watts, single side connection 230 volts surface and wall mounted LED type complete with all accessories internally pre wired and including connection up with twin core twisted flexible copper conductior cable of size 1.5 sqmm complete all as specified and directed by Eng-In-Charge. Make:- Havells cat No. LUMILINEBS9WLED865SPCWH or equivalent make as approved by GE.
S&F in repair/ replacement recess mounted circular LED slim fit low profile down lighter of capacity 18 watt , complete all as specified and directed by Eng-In-Charge. Make:- Havells cat part No EDGEPRORDDLR18WLED840S or equivalent make as approved by GE.
S&F in repair/ replacement recess mounted adjestable LED down lights made of extended aluminium housing and high power LED as a light sourse with clear diffuser and separate electric driver complete all as specified and directed by Eng-In-Charge. Make:- Havells cat part No SPARKLEPROADJDLR8W830MOD40D or equivalent of make as approved by GE.
S&F in repair/ replacement recess mounted LED sparkle pro snoot , wall washer light, tilted 70 digree out word and swivels 360 digree, energy saving complete all as specified and directed by Eng-In-Charge. Make:- Havells cat part No SPARKLEPROSNOOTDLR20W LED830MOD30D or equivalent of make as approved by GE.
S&F in repair/ replacement recess mounted LED light of capacity 24 watt, octena LED round panel, energy saving long life complete all as specified and directed by Eng-In-Charge. Make:- Havells cat part No LHEBHDP7IZ1W024 or equivalent of make as approved by GE.
S&F in repair/ replacement surface mounted round shape down light with white powder coated polycarbonate housing and pressure dicast heat sink having high efficiency complete all as specified and directed by Eng-In-Charge. Make:- Havells cat part No LHEAAGP7PL1W015 or equivalent of make as approved by GE.
S&F in repair/ replacement LED intigral LF 05 as IP 67, of bush light of capacity complete all as specified and directed by Eng-In-Charge. Make:- Havells cat part No LF05-600-055-27 XX or equivalent of make as approved by GE.
S&F in repair/ replacement in repair decorative wall mounting SS finish fixture with frosted glass suitable for 40 watt mini GLS E-27 lamp complete all as specified and directed by Eng-In-Charge. Make:- Havells cat part No LHFOFED1TZ1I040 or equivalent of make as approved by GE.
S&F in repair/ replacement in repair tube rod of cap 36 watt suitable for existing fittings of complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement in repair tube rod of cap 28 watt, T-5 type, 230 volts, complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement 11 Watt LED PL lights 4 pin complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement 18 Watt LED DU lights 4 pin complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement 18 Watt LED DU lights 2 pin complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement LED light on belt decorative type water proof, 40 feet length, colour blue, white, yellow with adaptor, suitable for 180 volt to 280 volt and as directed by Engr-In-Charge.
S&F in repair/ replacement LED bulb 12 watt yellow colour, minimum 900 lumens of suitable for 180 volt to 280 volt complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement decorative coloured flood light, suitable for focasing of tree/ buildings of capacity 100 watt, 240 volt, 50 HZ complete all as specified as directed by Engr -In-Charge.
S&F in repair/ replacement bulb retrofit type 7 watt LED bulb minimum lumens 600, suitable for 180 volt to 280 volt complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement bulb retrofit type 10 watt LED bulb minimum lumens 900, suitable for 180 volt o 280 volt complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement bulb retrofit type 15 watt LED bulb minimum lumens 900, suitable for 180 volt to 280 volt complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement electronic ballast suitable for 1x28 watts (530066 BJHF 128P) complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement electronic ballast suitable for 1x36/40 watts (530107 BJHF 136/ 140P) complete all as specified and directed by Eng-In-Charge.
Taking down ceiling fan/ cabin fan and dismantling fan blade, dismantling electric connection, removing capacitor, checking of bearings/bushes, cleaning the fan blades with clear water, scrapping the fan blades, placing the bearing, bush, capacitor, rewinding complete (rewinding, bush, bearing, capacitor, twin core, flexible cable will be paid under relevant items) reassembling the ceiling fan complete after greasing, oiling, testing the same & making the fan serviceable of any sweep and re-hanging and connecting up to the ceiling rose complete all as specified and directed by Eng-In-Charge.
All as per Item No 83 above, but for exhaust fan 450mm sweep, any type.
All as per Item No 83 above, but for exhaust fan 300/ 250/ 200mm sweep, any type.
All as per Item No 83 above, but for wall fan 250/ 400mm sweep, any type.
Re-winding in repair/ replacement of ceiling fan motor of any type and size including removing old burnt wire copper wire as per existing gauge & insulated paper, varnishing including cleaning/ greasing complete. Note:- Taking down & refixing of ceiling fan for winding, painting, replacement of bearing, bush, capacitor and alike will be measured & paid separately.
Rewinding in repair/ replacement only of exhaust fan with required guage super enameled wire including varnishing, insulation, taping complete of 450mm sweep complete all as specified and directed by Eng-In-Charge.
Rewinding in repair/ replacement only of wall fan with required guage super enameled copper wire including varnishing, insulation, taping complete of 250/ 350mm sweep complete all as specified and directed by Eng-In-Charge.
Rewinding in repair/ replacement only of exhaust fan with required guage super enameled wire including varnishing, insulation, taping complete of 200 to 380 mm sweep complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement capacitor for fan 2.5 MFD complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement capacitor for fan 3.15 MFD complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement electronic regulator switch type complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement electronic regulator socket type complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement cabin/ wall/ exhaust fan blade any sweep as existing complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement ball bearing for 1400mm/ 1200mm sweep ceiling fan as required at site complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement ball bearing for 450/ 300/ 230/ 200mm sweep exhaust fan as required at site.complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement gun metal bush for 1400/ 1200mm sweep ceiling fan as required at site complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement gun metal bush for 450/ 300/ 250/ 230mm sweep exhaust fan as required at site complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement rubber insulator heavy duty with bolts nuts & split pin etc complete for 1400/ 1200mm sweep ceiling fan complete all as specified and directed by Eng-In-Charge.
M&L for painting one coat of ceiling fan complete in situation with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning of dust etc of any sweep writing of MES No on ceiling fan any sweep after painting with suitable size of stansile and super enamelled black paint complete all as specified and directed by Eng-In-Charge.
M&L for painting one coat on exhaust fan complete in situation with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning of dust etc of any sweep writing of MES No on exhaust fan any sweep after painting with suitable size of stansile and super enamelled black paint complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement exhaust fan 350mm sweep silent type in PVC Body as required at site. complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement down rod 12mm dia made out of high density mild steel 600mm long as per approved sample complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement thermostat of water heater for 25 Ltrs capacity AC 230 V complete all as specified and directed by Eng-In-Charge. Make:- Theta/ Bajaj/ Danfoss as approved by GE.
S&F in repair/ replacement thermostat of water heater for 50 Ltrs capacity AC 230 V complete all as specified and directed by Eng-In-Charge. Make:- Theta/ Bajaj/ Danfoss as approved by GE.
S&F in repair/ replacement Water heater heating element for 25 Ltrs capacity 1.5 KW complete all as specified and directed by Eng-In-Charge. Make:- Theta/ Bajaj/ Danfoss as approved by GE.
S&F in repair/ replacement Water heater heating element for 50 Ltrs capacity 2 KW complete all as specified and directed by Eng-In-Charge. Make:- Theta/ Bajaj/ Danfoss as approved by GE.
S&F in repair/ replacement Water heater heating element for instantaneous electric water heater 3/6 Ltrs capacity 3 KW complete all as specified and directed by Eng-In-Charge. Make:- Theta/ Bajaj/ Danfoss as approved by GE.
S&F in repair/ replacement flexible hot water pipe steel cover wire of length not less than 6 fit with washer for hot and cold water for geyser connection.complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement flexible hot water pipe of length not less than 60 cm with washer for hot and cold water for geyser connection.complete all as specified and directed by Eng-In-Charge.
S&F in repair/ replacement Indicator lamp (red, green) including necessary connection in geyser capacity of 25/ 50 Ltrs complete all as specified and directed by Engr-in-charge. Note:- Rate quoted by tenderer is for each neon lamp.
S&F in repair/ replacement 2.5 Sqmm two core PVC insulated, unsheathed multistranded copper conductor flexible cable1100 volts grade complete all as specified and directed by Engr in Charge.
S&F in repair/ replacement 1.5 Sqmm two core PVC insulated, unsheathed multistranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge.
S&F in repair/ replacement Geyser Assembly 6 hole/ 9 hole of water heater for 25 Ltrs capacity AC 230 V complete all as specified and directed by Eng-In-Charge. Make:- Theta/ Bajaj/ Danfoss as approved by GE.
S&F in repair/ replacement Geyser Assembly 6 hole/ 9 hole of water heater for 50 Ltrs capacity AC 230 V complete all as specified and directed by Eng-In-Charge. Make:- Theta/ Bajaj/ Danfoss as approved by GE.
S&F in repair/ replacement Geyser Cover top/ bottom of water heater for 25/ 50 Ltrs capacity AC 230 V complete all as specified and directed by Eng-In-Charge. Make:- Theta/ Bajaj/ Danfoss as approved by GE.
S&F in repair/ replacement Outer Body of water heater for 25 Ltrs capacity AC 230 V complete all as specified and directed by Eng-In-Charge. Make:- Theta/ Bajaj/ Danfoss as approved by GE.
S&F in repair/ replacement upper body of water heater for 50 Ltrs capacity AC 230 V complete all as specified and directed by Eng-In-Charge. Make:- Theta/ Bajaj/ Danfoss as approved by GE.
S&F in repair/ replacement acoustic insulation wool of water heater for 25/ 50 Ltrs capacity AC 230 V complete all as specified and directed by Eng-In-Charge. Make:- Theta/ Bajaj/ Danfoss as approved by GE.
ALBA AC AND REF SERVICES
TECH SERVE SOLUTIONS
SNEH TRADERS
M/s SK Traders
Shree Builders
M/s PATEL ENGINEERING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .