Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | Single₹2.7 CrAccepted-AOC | ₹2.7 Cr | Single | Accepted-AOC Work awarded and Agreement executed |
Tender Value
₹2.5 Cr
EMD Value
₹1 L
Closing Date
26 Dec 2023, 3:00 pmClosed
Superintending Engineer
Superintending Engineer, Kerala Water Authority, P.H Circle, Kochi-11
AMRUT GLSR at Thrikkakara WSS to Thrikkakara Construction of GLSR Pump House Supplying and errection of VT pump sets Pipeline Work
2023_KWA_634451_1
Re -E-Tender No 225/2023-24/SE/PHC/CHN
Open Tender
Civil Works - Water Works
Item Rate
270 days
Thrikkakara
Please refer Tender documents.
8 documents required · 8 mandatory
₹9,759
₹1 L
22 Feb 2024
21 Dec 2023
27 Dec 2023
21 Dec 2023
26 Dec 2023
21 Dec 2023
Amount
Appendix A- Construction of Sump(10 LLcapacity)
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
2.16.1:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5m
2.16.2:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth exceeding 1.5 m but not exceeding 3 m
4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.18:Neat cement punning
13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
OD227844/2022-2023:Supplying and fitting 150mm CI Ventilation cowl wrapped with aluminium mesh to prevent insects, fitting during casting roof slab of the sump
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
OD239511/2022-2023:Supplying and fixing 1200mm x 1200mm MS manhole cover with frame charges including all cost, labour charges etc., complete.
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
OD263027/2022-2023:Supplying and providing water level indicator to the tank using scale fabricated out of 2mm<br>thick MS plate with in the frame work of suitable size MS square tube, 160mm PVC pipe for guiding the float,<br>necessary pullyes, suitable nylon thread for connecting float and level indicator, painting the entire structure, lettering<br>etc complete including all charges for material and labour for GL tank
Apendix B- Construction of Pump House
2.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
2.2.1:Earth work in rough excavation, banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead up to 50 m and lift up to 1.5 m:All kinds of soil
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
13.62.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .
50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
17.3.1:Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
17.7.4:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
17.10.2.3:Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink without drain board470x420 mm bowl depth 178 mm
17.29:Providing and fixing 100 mm sand cast Iron grating for gully trap.
17.31:Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
OD44996/2022-2023:Providing and fixing aluminium work for doors,windows,ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285,fixing with dash fastners of required dia and size,including necessary filling up the gaps at junctions,i.e,at top,bottom and sides with required EPDM rubber/neoprene gasket etc.Aluminium sections shall be smooth,rust free,straight,mitred&jointed mechanically where ever required including cleat angle.Aluminium snap beading for glazing/paneling,C.P brass/stainless steel screws,all complete as per architectural drawings and the directons of engineer in charge. (External member = 1.653 kg/m,Internal member =1.692 kg/m,Door frame-Hanging style=2.53kg/m,meet style=2.465 kg/m,top&bottom=2.48kg/m,Lock rail=2.53 kg/m)
OD44997/2022-2023:Design manufacture and supply and installation of HOT overhead travers trolly crane 5 tonne capacity chainpully block and geared rolley having wall to wall horizontal movement etc for smooth functioning of the crane as per IS Specificationincluding all fittings and all incidental charges including painting the exposed surface with following specifications Typa and construction of crane Single gurder HOT (Design code IS 3832) Hook IS 8610 Load chain IS 6216(Alloy steel Grade 80) Hand chain IS 2420 MS Grade 30 brake type self actuating screw friction and disc type
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
13.50.4:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)
OD213840/2022-2023:Providing and fixing concrete jalli for walls etc complete including the cost of all material, labour, and conveyance etc complete as per the direction of department officers
OD227886/2022-2023:Supplying and errecting of ferrocement septic tank ,1.65Mx1.00mx1.1m size including soak pit
OD45078/2022-2023:Plumbing and sanitation work
OD227911/2022-2023:Electrification of pump house & starter room including Earthing with G.I. earth pipe with accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required, Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. , Supplying and fixing of MCB distribution board of sheet steel, dust protected, duly powder painted, Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required and other allied works
9.119:Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer-in Charge.
9.120.1:Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufacture's specification & drawing.30 mm thick plain PVC door shutters
10.16.2:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
Appendix C- Providing and Fixing VT pump Set and allied works
OD8984/2023-2024:Supply of KWA pre- qualified reputed make slow speed Vertical turbine pump with bronze/SS impeller, SS shaft and CI pump casing with MS ERW column pipe of suitable diameter and length with coupling, foundation bolt & nuts etc.complete suitable for coupling the pump and motor. The duty condition as follows. Discharge-175 LPS Total head- 40 mtrs
OD9073/2023-2024:Motor:- Supply of KWA prequalified reputed make vertical hollow shaft TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz. AC supply, working voltage 415 V (suitable for the pumpset) digital motor protection relay shall be included in starter as per present CEA regulation. The energy efficient level of motor confirm to IE2/IE3 as per IS 12615-2018. Flexible coupling shall be used for coupling of pump and motors
OD9039/2023-2024:Starter:- Supply suitable rating (Fully automatic ATS starter with air break contact for less than 50 HP and for above 50 HP FCMA starters to be used) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per CEA regulation 2010 and code of practice etc. Complete
OD9104/2023-2024:Earthing:- Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards
OD9151/2023-2024:Cabling work:- Supply, laying, testing and commissioning of suitable size XLPE cables(3.5 core 300 sq,mm) for the above pump set from bus bar to panel board , panel board to starter and from starter to motor considering energy conservation.
OD9158/2023-2024:Capacitor:- Supply, erection, testing and commissioning heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834.
OD9163/2023-2024:Delivery pipe connections :- Supply and fitting of suitable size best quality GI/MS pipe suitable for the above pump set connecting the delivery pipe and valve with suitable flanges, nut and bolts, IR sheet etc. complete with bypass arrangements, supply and fitting pressure guage of suitable rating with main cock and connecting the delivery side of the pumping main using Y connection. If the dia of suction pipe is above 80 mm CI/DI pipes & specials shall be provided
OD9164/2023-2024:Valves:- Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump sets sluice valve should be in suction as well as delivery sides for easy repair works.
100.31.1.11:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 500mm diameter, Class I.
100.98.467:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 500mm.
OD221436/2022-2023:Supply, laying, testing and commissioning of suitable size XLPE cables for additional length for providing connection
OD15178/2023-2024:Erection of pump , motor , starter , panel board etc on suitable concrete foundation , fitting strainer, column pipe, discharge head etc, fitting motor ,coupling with pump shaft , providing electric connections, trial run etc complete.
OD45120/2022-2023:Interconnecting the existing inlet pipe with new sump by cutting the existing line and jointing the same with suitable specials like Tee, Reducer, Mechanical joints ect. including the cost of materials and all labour.
OD240149/2022-2023:Interconnect the over flow pipe with existing 500mm AC out let with the cost of pipe and all specials including all materials and labour
OD228284/2022-2023:Interconnect the Out let pipe with the existing 500mm AC outlet by cutting the line and jointing with suitable specials like tee, mechanical joints etc, including the cost of the header pipe, all materials and labour
Bidder Name
P B Dinesh Kumarr
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_962638.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .