Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.6 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹57.0 L+₹39,315.17 (0.69%)Rejected-AOC | L2 | Rejected-AOC 2nd lowest |
Tender Value
₹51.4 L
EMD Value
₹50,000
Closing Date
10 Oct 2023, 11:00 amClosed
The Regional Project Director, KRWSA Malappuram
Kerala Rural Water Supply and Sanitation Agency, Regional Project Management Unit, Malappuram, MMC.X/108-112, UMK Tower, Uphill, Jubilee Road, Near Passport Office, Malappuram P.O. - 676 505
Jal Jeevan Mission Package 6C - Full coverage to Nayadampoyil ST Colony (ward 1) in Chaliyar Grama panchayath in Malappuram District
2023_KRWSA_605163_1
44/JJM/KRWSA/MPM/CH6C/2023
Open Tender
Civil Works - Water Works
Item Rate
270 days
Chaliyar GP in Malappuram District
As per NIT
7 documents required · 7 mandatory
₹2,500
₹50,000
5 Mar 2024
21 Sept 2023
11 Oct 2023
21 Sept 2023
10 Oct 2023
21 Sept 2023
21 Sept 2023 - 28 Sept 2023
Amount
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Lettering with black Japan pint of approved brand and manufacture
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 75mm Dia
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 40mm Dia.
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 50mm Dia.
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 63mm Dia
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 90mm Dia.
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 25mm
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 32mm Dia.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :" Ordinary Rock.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m Hard Rock(Requiring Blasting).
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and laying charges of pipe specials of same class as that of pipe). 90 mm nominal outer dia pipes."
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and laying charges of pipe specials of same class as that of pipe). 75 mm nominal outer dia pipes.
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and laying charges of pipe specials of same class as that of pipe).25 mm nominal outer dia pipes
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and laying charges of pipe specials of same class as that of pipe).32 mm nominal outer dia pipes.
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and laying charges of pipe specials of same class as that of pipe).40 mm nominal outer dia pipes
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and laying charges of pipe specials of same class as that of pipe) 50 mm nominal outer dia pipes.
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and laying charges of pipe specials of same class as that of pipe).63 mm nominal outer dia pipes.
Providing and fixing medium G.I. pipes complete with G.I fittings including trenching and refilling etc. External work20 mm dia nominal bore
Providing and fixing medium G.I. pipes complete with G.I fittings including trenching and refilling etc. External work25 mm dia nominal bore
Providing and fixing medium G.I. pipes complete with G.I fittings including trenching and refilling etc. External work32 mm dia nominal bore
Providing and fixing medium G.I. pipes complete with G.I fittings including trenching and refilling etc. External work80 mm dia nominal bore
Providing and fixing medium G.I. pipes complete with G.I fittings including trenching and refilling etc. External work65 mm dia nominal bore
Providing and fixing medium G.I. pipes complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore
Providing and fixing medium G.I. pipes complete with G.I fittings including trenching and refilling etc. External work40 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, stand post with 63 mm 6kg/cm2 pvc pipe height of 1 mtr, concrete palform of size 60*60*7.5cm,but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
Providing 15mm PVC Tap in the water meter assembly for 15mm (1/2 inch ) water connection, using 20mm ( 1/2 inch ) Indian Standard uPVC Class 6 pipes, uPVC specials and PP PN 16 Compression specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.
Testing water sample from the source of scheme at any Government laboratory and submitting the report - both physical and bacteriological parameters
Surveying with Electronic Total Station with single prism in normal terrain and normal traffic.
Conducting field inspection, analyzing the survey results and other collected data collected during field inspection, designing the pipe line networks using the EPANET for providing hydraulically feasible FHTCs by engaging techanically qualifying experts including cost of all conveyance, hire and labour charges for computer software, printing charges etc complete.
Supplying and stacking for measurement of filter sand having effective size 0.45 to 0.70 mm and uniformity coefficient 1.30 to 1.7, of specific gravity in the range of 2.55 - 2.65 and hard and clean, free from clay, dust and other impurities including cost of materials, labour charges and conveyance of materials up to 5 km and as per the directions of the department officers etc. complete and as per CPHEEO specification
Supplying of 2 to 6 mm and 6 to 12 mm size fine pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc. complete as per CPHEEO specifications.
Supplying of 12 to 20mm size pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc complete and as per CPHEEO specification.
Supplying of 20 to 40 mm pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per directions of the department officers etc. complete and as per CPHEEO specification
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
Removing white or colour wash by scrapping and sand papering and preparingthe surface smooth including necessary repairs to scratches etc. complete
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
White washing with lime to give an even shade:New work (three or more coats)
Providing 15mm (1/2 inch) GM Air Valve in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of consumables, hire for tools and labour charges etc., complete but excluding cost of materials and as per the directions of the department officers.
DOWEL BARS - Supplying and providing MS dowel bars of size 16 mm dia of 2m long (1m in rock and 1m in concrete ) including drilling holes of 20mm dia to a depth of 1m in rock and filling the gap with cement grout( 0.10kg/each) etc complete.
Supply,installation and commissioning of 1 number of chlorine dosing system with all necessary accessories based on the site conditions and as directed by the Engineer in charge. The chlorine solution shall be directly injected to the system at suitable point by using suitable chemical dosing pump (solenoid dosing metering pump) having adjustable discharge and with a capacity of minimum discharge of 5 litres/hour at a delivery pressure of 10Kg/cm2 so as to maintain required residual chlorine in the treated water as per the norms including best quality tank (capacity not less than 50litres) with top cover and all other accessories and wiring from existing panel board to the pump set by using power cables encased in PVC conduit and trial running etc
Sebastian T V
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .