EE PHED NO.1 ROHTAK
EE PHED NO.1 JHAJJAR ROAD ROHTAK
Ballab Construction of Raw water Pumping station near Bhutiyan Minor at RD 16600 R Design Construction Testing and commissioning of 050 MLD water treatment plant Cons of 2 Nos RCC S S Tank 1 No CWT Pump Chamber Boundary wall Road and Path Lay
2020_HRY_146649_1
DNIT approved vide SE No. 9200 dt 29.09.2020
Open Tender
Civil Works
Works
560 days
VPO Ballab
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
Executive Engineer
₹8.5 L
Yes
7 Nov 2020
1 Oct 2020
22 Oct 2020
1 Oct 2020
21 Oct 2020
1 Oct 2020
Amount
Design, Testing, Commisssioning of automated PLC controlled SCADA based water purification plant of 0.50 MLD capapcity at proposed water works Ballab, all other installation etc comprising of DI pipe from Raw water main/pump, inlet box ofWTP and to CWP to CW suction well inlet channel, ALum dozing, flash mixing, clari floculator, filter box, overhead resevoir for back wash including pump sets and electric control pannel waste water tank including pump sets and electric control pannel, DI pipes, DI specials, manhole covers, air scour equipment, chemical house including chlorination equipment and arrangement of floe mesurement and sand bed with automation complete in all respect as per NIT (Sluice valve of make IVC/VAG
Pumping Machinery Raw water pump sets
Supply & erection of horizontal spindal split casing type pumping sets of following duties directly coupled to AC squirrel in schedule-II complete in all respect with priming arrangement with base frame . A) RAW WATER PUMPING STATION NEAR BHUTIYAN MINOR AT RD-16600-R 1600 LPM with 25M Head & 15 BHP
B) PROPOSED WATER WORKS BALLABH 1100 LPM with 12M HEAD & 5 BHP for Raw water
1100 LPM with 40 M HEAD & 20 BHP for Clear water
Supply and fixing following CI D/F pipe And specials/sluice valves/non return valves/bell mouth/Reflex valves including cost of jointing materials, excavation, laying, jointing, refilling including making adequate supports of masonry/concrete/steel for delivery and suction pipe from bell mouth in the collecting tank upto the rising main laid by the department as per plan shown from the foundation wall of the pump chamber for all the clear water pumping sets at water works, as per specification given in schedule No. II Details of pipe and specials Raw water Pump House, Proposed water works Ballabh
Supply, erection, testing and commissioning wall mounted electrical panel board fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm & 400mm deep having following items:- (a) Incomer Switch 200 Amp (b) Aluminiuam Bus Bar Chamber of 200 Amp Capacity (c)Volt meter 100x100mm range of 500V ( AE/KAPPA/L&T) (d) Indicating lamp one set (Raw water pump House & proposed water works Ballab) (Inside pump chamber)
Panel Bord for Motors
Supply, erection, testing and commissioning wall mounted electrical panel board fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm & 400mm deep having following items:- For Raw Water Pump Sets for 1600 LPM x 25 Mtrs. Head = 1 Nos. (One for each pump set) at Raw water Pump House Near Bhutiyan Minor at RD 16600-R (a) Main Switch 100 Amp 1 No. (L&T Siemens, ABB) (b) Volt meter 100x100mm range 0 to 500 volt =1 No. (AE/KAPPA/L&T) (c) Amp. Meter 100x100 mm range 0 to 100 Amp = 2 Nos. ( AE/KAPPA/L&T) (d) CT 100 / 3 Nos. ( AE/KAPPA/L&T) (e) VSS & ASS = 1 No. each of approved make. (f) SSP 4 Nos. of approved make/ minilac (g) Motor starter, Star Delta 1No. for 1600 LPM x 25 mtrs. Head Motor (L&T, Siemens, ABB). (h) Capacitor KVAR as per site requirement (i) Indicating Lamp = One set (j) Change over switch 200 Amp = 1 No.
Supply, erection, testing and commissioning wall mounted electrical panel board fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm & 400mm deep having following items:- For Raw Water Pump Sets for 1100 LPM x 12 Mtrs. Head = 1 Nos. (One for each pump set) at Proposed water works Ballab (a) Main Switch 32 Amp 1 No. (L&T Siemens, ABB) (b) Volt meter 100x100mm range 0 to 500 volt =1 No. (AE/KAPPA/L&T) (c) Amp. Meter 100x100 mm range 0 to 100 Amp = 2 Nos. ( AE/KAPPA/L&T) (d) CT 100 / 3 Nos. ( AE/KAPPA/L&T) (e) VSS & ASS = 1 No. each of approved make. (f) SSP 4 Nos. of approved make/ minilac (g) Motor starter, Star Delta 1No. for 1100 LPM x 12 Head Motor (L&T, Siemens, ABB). (h) Capacitor KVAR as per site requirement (i) Indicating Lamp = One set (j) Change over switch 63 Amp = 1 No.
Supply, erection, testing and commissioning wall mounted electrical panel board fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm & 400mm deep having following items:- For Clear Water Pump Sets for 1100 LPM x 40 Mtrs. Head = 1 Nos. (One for each pump set) at Proposed water works Ballab (a) Main Switch 100 Amp 1 No. (L&T Siemens, ABB) (b) Volt meter 100x100mm range 0 to 500 volt =1 No. (AE/KAPPA/L&T) (c) Amp. Meter 100x100 mm range 0 to 100 Amp = 2 Nos. ( AE/KAPPA/L&T) (d) CT 100 / 3 Nos. ( AE/KAPPA/L&T) (e) VSS & ASS = 1 No. each of approved make. (f) SSP 4 Nos. of approved make/ minilac (g) Motor starter, Star Delta 1No. for 1100 LPM x 40 Head Motor (L&T, Siemens, ABB). (h) Capacitor KVAR as per site requirement (i) Indicating Lamp = One set (j) Change over switch 200 Amp = 1 No.
Supply, erection, testing and commissioning in HT epoxy type cable boxes for 35mm HT / 11 KV XLPE 3 Core galvinized steel strip armoured cable including material/required for complete errection of same such as thimble lugs, Solder compound etc complete in all rerspect as described in Schedule-II as per approved NIT For outdoor Installation
For Indoor Installation
DIESEL GENERATING SET AT RAW WATER PUMNP HOUSE NEAR BHUTIYAN MINOR AT RD-16600-R
Design, Supply and erection of DG set 25 KVA of required capacity given below with acoustic of suitable rating with change over switch switch fenced encloser with plateform DG sets complete as per DNIT The rating should be at 1500 LPM a) Diesel Engine b)Alternator C) Battery 24V d) Base Plate e) 1X50 sq mm 3.0 core XLPE aluminum = 20m f)Tools A.M.F PANEL a) Motorised change over switch 63 Amp 4 P with fuse base and HRC links 63 Amp. b) under voltage/over voltage relay -2 No. 415 VAC c) Engine Star replay 24 VDC 1 No. d) Electronic Timber 24 VDC 1 No. e) Electronic Timber 24 VDC 2 No. f) Auxiliary relay 220 VAC -2 Nos. g) Auxiliary relay 220 VAC -3 Nos. h) Metering set 415 VAC -1 Set(Amp Meter, Volt meter , ASS, VSS, Phase Indicaters, Control Fuse, frequency meter, CT's) i) Metering set 24 V DC (Amp. Meter V-Meter)j) Overload protection for DC -1 No. k) Battery charger 24 V DC (Bluron make) l)Copper Bus bar of suitable size m)KWH Meter 96 sqrmm size n) Starting fuse button and key switch (on/off) O) Engine protction unit with Audiovisual alarm and shut down for low lubricating oil pressuere high collent tempreture p) Indicating lump for low lubricating oil pressuere high collent tempreture, set running, load on, DC Control on Note:- Control pannel shell have the provision to provide auto manual failure panel(AMFP)
Raw water pump House 25 KVA
Transformer Design, Supply and erection of transformer of standered make required KVA 11/0.433 KVA rating type outdoor type 11 KVA VCB panel G.O Switch H. Pole H.T metering panel, APFC panel battery charges, 11 KVA substation, entire cable netwrok from G.O switch to HT metering equipement and from HT metering to transformer from metering to transformaer, from teansformer to main LT panel, erthing safety equipement fenced enclosure for transformer and any other contingent thereto complete in all respect as per DNIT(Make KIRLOSKAR, Crompton & GEC) required at following sites as per respective capacity
A) Raw water Pump House 20 KVA
Providing and fixing of DI Air valve IVC Brand soft seated as confriming to ISI complete in all respect (Pump House DI rising main to proposed water works Ballab. 80 MM
Supply erecting testing and commissioning of exhaust fans each having capacity of 45 cubic meters per minutes complete with suitable G,I Sheet Ducting in meter room and pump chamber and ergency for the sites (Pump house & water Works)
Supply erecting testing of Ceiling fans of size 48" i/d (1200mm) of reputed ISI make complete in all rewspect (Pump house & water Works)
Supply erecting testing of light fitting including wire in the pump chamber with material upto 10 points including switch, button plug PVC conduct pipe & copper wire etc as per approved specifications (Pump house & water Works)
Providing and fixing insulated Rubber matting suitable for HKV installation 1 meter X 2 meter X 12mm as per specifiaction (Pump House & water works)
S & S Tank a) Providing and fixing suitable floating Arms 250 mm size alonwith swivel bend as per required specification approved by Engineer-in-Charge
b) Providing and fixing of PVC water Bar (Fixo-stop) with ribs & central bulbs of size give below confomed to IS-12200 of 1987 (Fixo-stop) along with the bitumen board including cost of bitumand filler complete i) 250mm wide X 80 to 11 mm thickness (1 No. RCC Raw water Reservior at pump House, 2 Nos. RCC & S&S Tank, 1 No. CWT at water works)
Supply erection and commissioning electric operated dewatering puump of 3 HP Kirloskar make complete from priming with wiring staters qwitches etc. also the required GI pipe (B Class) valves and sight glass etc complete.
Supply and fixing of Gantry with chain pulley block of 2 tones capapcity with traveling with appropriate lifiting capacity for handling of pumping sets capable of moving along the girders to be provided in the pump chamber of water works complete in all respect as per details in DNIT
Supply erection testing and commissioning of flow meter (Krone Make) with digital display of 150mm dia i/d complete in all respect (For rising main & water works to B/Station)
Supply and fixing of G.I Nipple 1/2" X 4" complete in all respect and the entire satsfaction of Engineer-in- Charge (Make Jindal/Parkash/Tata) complete in all respect
Supply and fixing of G.I Socket 1/2" complete in all respect and the entire satsfaction of Engineer-in- Charge (Make Jindal/Parkash/Tata) complete in all respect
Supply and fixing of G.I Elbow 1/2" complete in all respect and the entire satsfaction of Engineer-in- Charge (Make Jindal/Parkash/Tata) complete in all respect
Operation and maintenance for complete scope of work mention in the DNIT ( Disinfection material supplied by the PHED) as per Schedule-IV for a period 5 year after 12 month during defect liablity period 3 months trial run will be charged to the A/Mtc estimate
Operation and maintenance during defect liability period (Operation only)
Operation and maintenance during 1st year after defect liability period
Operation and maintenance during 2nd year after defect liability period
Operation and maintenance during 3rd year after defect liability period
Operation and maintenance during 4th year after defect liability period
Operation and maintenance during 5th year after defect liability period
Bidder Name
Amount
Sh. Ashok Kumar Sindhu
Om Parkash Sindhu
Om Parkash Sindhu
Om Parkash Sindhu
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .