Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.1 CrAccepted-AOC HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹9.1 Cr | 1 | Accepted-AOC Being Lowest Tenderer |
| 2 | 2₹9.8 Cr+₹60.3 L (6.59%)Rejected-Finance B 604 VASUNDHRA APARTMENTS PLOT NO 16 SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹9.8 Cr+₹60.3 L (6.59%) | 2 | Rejected-Finance Other than Being Lowest Bidder |
| 3 | 3₹10.2 Cr+₹1.0 Cr (11.1%)Rejected-Finance | ₹10.2 Cr+₹1.0 Cr (11.1%) | 3 | Rejected-Finance Other than Being Lowest Bidder |
| 4 | 4₹11.0 Cr+₹1.8 Cr (20.1%)Rejected-Finance F 18 ANSAL COMPLEX OPP JWALA HARI MARKET PASCHIM VIHAR NEW DELHI 110063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹11.0 Cr+₹1.8 Cr (20.1%) | 4 | Rejected-Finance Other than Being Lowest Bidder |
| 5 | 5₹11.1 Cr+₹1.9 Cr (21.2%)Rejected-Finance 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹11.1 Cr+₹1.9 Cr (21.2%) | 5 | Rejected-Finance Other than Being Lowest Bidder |
Tender Value
₹8.5 Cr
EMD Value
₹7.5 L
Closing Date
13 Feb 2023, 6:00 pmClosed
CE AF ALLAHABAD
HQ CE AF ALLAHABAD
CONSTRUCTION OF PERMANENT BUILDING FOR STATION MEDICARE CENTRE (SMC) AT AF STN BAREILLY
2022_MES_515568_1
958106/E8
Open Tender
Civil Works
Lump-sum
730 days
AF STN BAREILLY
AS PER NIT
8 documents required · 8 mandatory
₹3,000
Yes
GE (AF) Bareilly
₹7.5 L
Yes
HQ CE AF ALLAHABAD
13 Jun 2023
29 Mar 2022
18 Feb 2023
29 Mar 2022
13 Feb 2023
30 Jan 2023
13 Apr 2022 - 20 Apr 2022
22 Apr 2022
Amount
SCHEDULE A PART I (BUILDING WORKS)
Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part I .
Sch A Part II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II .
Sch A Part III (INTERNAL ELECTRIFICATIONS)
Lump sum price worked out by the contractor for Internal Electrifications as listed in Sch ‘A’ Part III .
Sch A Part IV (EXTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part IV .
Sch A Part V (EXTERNAL ELECTRIFICATIONS)
Lump sum price worked out by the contractor for External Electrifications as listed in Sch ‘A’ Part V.
Sch A Part VI (SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part VI.
Sch A Part VII (AREA DRAINAGE)
Lump sum price worked out by the contractor for Area Drainage as listed in Sch ‘A’ Part VII
Sch A Part VIII (ROAD/ PATH & HARDSTANDING)
Lump sum price worked out by the contractor for Road/Path & Hardstanding as listed in Sch ‘A’ Part VIII
Sch A Part IX (INCINERATOR )
Lump sum price worked out by the contractor for Incinerator as listed in Sch ‘A’ Part IX.
Sch A Part X (REFRIGERATION AND AIR CONDITIONING)
Lump sum price worked out by the contractor for Refrigeration and air conditioning as listed in Sch ‘A’ Part X.
Sch A Part XI (LIGHTENING PROTECTION)
Lump sum price worked out by the contractor for Lightening Protection as listed in Sch ‘A’ Part XI
Sch A Part XII (SOLAR WATER HEATER)
Lump sum price worked out by the contractor for Solar Water Heater as listed in Sch ‘A’ Part XII
Sch A Part XIII (CONDUIT FOR TELECOMMUNICATION)
Lump sum price worked out by the contractor for Conduit for Tele communication as listed in Sch ‘A’ Part XIII
Sch A Part XIV (DEMOLITION DISMENTALING)
Lump sum price worked out by the contractor for Demolition Dismentaling as listed in Sch ‘A’ Part XIV
Sch A Part XV (Miscellaneous Items of B/R and E/M)
S & F concealed type MCB protected Power Unit having GI Sheet box, PVC enclousure for Modular switches / sockets etc. complete with a 25 Amps modular type motor starter(2 Module) with one single pole Modular type 'C'curve MCB of capacity 20 Amps (1 Module) & a 20 Amps 3 pin modular socket(2 module) including electrical connections all as specified and directed by Engr-in-charge. (For Air Conditioners)
S&F surface munted downlight LED light fitting 12 W with aluminium dia-cast housing complete with all accessories and making connection by using suitable length of three core flexible copper cable of size 23/0.0076 complete all as specified and directed. Make : Halonix (Cat No : HLDLS-R06-12-CW / Havells (Cat No : LHEAAVP5IL1W012) Bajaj ( Cat No : BGSLO SLEEK SURFACE 12W WH RD) or equivalent model in list of Makes mentioned in tender.
Supply and fixing LED street light 35/36 watts made up of pressure die cast housing with toughned glass/ PC cover and individual high power LEDs with secondary optics,min. IP65 protection complete all as specified and directed by Engr-in-Charge. Make :Halonix-HLSLD-14-36-CWL Havells - ENDURACITYLITEPLATPLUSSL35WLED757SASYBOPC Bajaj - BRTFG 36W LED or equivalent model in list of Makes mentioned in tender.
S & F Wall / surface mounted type Bulk Head LED light fitting complete with LED lamp 10 watt , made of polycarbonate housing & enclosed with cover and integrate electronic driver complete with all accessories internally pre-wired and including connecting up with 3 core twisted flexible copper conductor cable complete all as specified and as directed. Make :- Halonix (Cat No :HLBH-03-10-CW) Havells (Cat No : HEXAFT10WLED857SSYMBOPC) Bajaj (Cat No :BIBWP 10W LED) or equivalent model in list of Makes mentioned in tender.
M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron strip of size 25mm x 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 40 mm GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally upto 150mm below ground level , GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results on a 3.0mm thick painted M.S. earth pit marking Plate (200mm x 100mm) duly welded with a 450mm long 10mm dia round M.S. rod, fixed with the earth pit chamber by grouting complete all as specified and directed.
M&L for Construction of valve chamber of size 900 x 900 x 900 mm internal size suitable for valves with PCC 1:4:8 type D2 for foundation and brick wall in cement mortar 1:4 PCC 1:2:4 type B1 for coping rendering in CM (1:4) 15mm thick including provn of mild steel sheet cover 3.15mm thick on 40x40x6mm angle iron frame work with two coats of synthetic enamel black paint over a coat of red oxide primer and locking arrangement including necessary excavation earth work all as specified and directed.
Taking off existing covers of septic tank , soakage well, soak pit, sewage pump or manholes of any size and depth and cleaning the same by dewatering the water and taking out complete sludge and other foreign material in liquid, semi liquid, mud, silt or in solid state by manually or mechanically after emptying the water by mechanical pumping after plugging the inlets if required, and removing the sludge to a distance not exceeding 1500 m outside of the defence area and burying the same in newly excavated pits of suitable sizes and covering the same with excavated earth and placing back in position the removed covers and set in CM 1:4 complete all as specified and directed. Note :- The excavation and earth work of pit in any type of soil is deemed to be included in the unit rate of this item. No extra payment shall be made for de-watering which shall deemed to be included in unit rate of this item. Net quantity of sludge (Solid content) as removed shall be measured and paid.
M&L for septic tank of capacity 25 users including excavation in ordinary soil, foundation using PCC 1:2:4 type B-1 (Using 20 mm graded stone aggregate), brick work in CM 1:4, internal plaster 15 mm thick in CM 1:4 with WPC, RCC slab incl precast RCC manhole cover having 6 mm plate embedded all around with angle iron vent shaft and sludge chambers etc complete all as specified and shown on TD drgs .
M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M-25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 3.0 M effective depth complete all as specified and directed as per TD-576 Sheet 01/02 and 02/02 of CE Lucknow zone complete all as specified and directed.
M & L Boring holes under road, pavement, hard standing by trenchless technology by using ultra sounding technic and necessary machine complete all as specified and directed.
Supply and laying galvanised iron pipe of size 150 mm dia, medium grade, ISI marked for laying in trenches , under road and Hard standing complete all as specified and directed.
Supply and laying HDPE pipe of size 150 mm dia suitable for 0.4 Mpa working pressure for laying in trenches , under road and Hard standing complete all as specified and directed.
Design, supply, erection, testing and commissioning of indoor type LT Panel Board of overall size not less than 1800 mm width x 1500mm Height (Without Base Channel) x 800mm Depth, M.S. Channel (75MC) Base Frame mounted (to be mounted on the brick. pedestal of height 300mm above floor level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 1000 amps, Provision of Spreader link to both incoming & Outgoing MCCBs for termination of cables . The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication House who posseses type test certificate from CPRI for similar type of Panel Board and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Panel Board shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-52 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front & rear opening facility with locking facility .
The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :- Location : Proposed Sub-Stn Bldg ( LT Panel No-1) INCOMING :- (i) S&F Air Circuit Breaker (ACB) 4 pole, suitable for 3 phase 4 wire system having double break main contacts and of rating 630 Amps with breaking capacity 50 KA, Electrical Draw Out Type,Breaking time not more than 30 mili seconds with adjusted overload short circuit trip setting complete with all standard accessories and as described in P.S. - 01 No OUTGOINGS :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having fixed type thermal and magnetic setting Ics = 100% Icu and of ratings :-500 Amps - 01 No (250 KVA AMF Panel) (ii) 4 pole MCCB ( with panel mounted rotary handle ) having fixed type thermal and magnetic setting Ics = 100% Icu and of ratings :-125 Amps - 02 Nos ( 63 KVA AMF Panel + Spare)
Note : All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. (2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. (3) All the inner / outer doors should have locking facility through castle locks (4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. (5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. (6)The thickness of MS Sheet for outer shell and canopy shall be of 2.0mm and inner doors and partitions shall be of 2.0 mm (7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. (8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
Design, supply, erection, testing and commissioning of indoor type LT Panel Board of overall size not less than 2100 mm width x 1500mm Height (Without Base Channel) x 450mm Depth, M.S. Channel (75MC) Base Frame mounted (to be mounted on the brick. pedestal of height 300 mm above floor level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 800 amps, Provision of Spreader link to both incoming & Outgoing MCCBs for termination of cables . The Panel Board shall be duly fabricated in a approved / certified factory / fabrication House who posseses type test certificate from CPRI for similar type of Panel Board and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Panel Board shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-52 and general construction conforming to IS : 13947. The Panel Board shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front & rear opening facility with locking facility . The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation.
The feeder pillar shall be comprising of the followings :- Location : Proposed Sub-Stn Bldg (Main LT Panel No-2) INCOMING :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having adjustable magnetic and adjustable thermal setting from 80% to 100% and of rating 500 Amps-01 No. - 01 No OUTGOINGS :- a) 4 pole MCCB ( with panel mounted rotary handle ) having fixed type thermal and magnetic setting Ics = 100% Icu and of ratings :-125 Amps - 02 Nos (To ATS of Change Over Panel + To Manual Change over switch of Change Over Panel for Main Lighting Panel) b) 4 pole MCCB ( with panel mounted rotary handle ) having fixed type thermal and magnetic setting Ics = 100% Icu and of ratings :-100 Amps - 02 Nos (Power / AC Panel + Spare) c) 4 pole MCCB ( with panel mounted rotary handle ) having fixed type thermal and magnetic setting Ics = 100% Icuand of ratings :-32 Amps - 02 Nos (Patient Lift & Goods Lift) d) 4 pole MCCB ( with panel mounted rotary handle ) having fixed type thermal and magnetic setting Ics = 100% Icu and of ratings :-40 Amps - 01 No (Spare) e) TPN MCB of rating 16 Amps 10 KA - 01 Nos ( For Area Lighting) f) 3 Pole Power Contactor 16 Amps - 01 No ( For Area Lighting) g) Analog Time Switch 16 Amps - 01 No ( For Area Lighting) h) DOL Starter - 3.0 H.P. - 01 No. (For Fountain Pumpl)
Note : All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. (2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. (3) All the inner / outer doors should have locking facility through castle locks (4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. (5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. (6)The thickness of MS Sheet for outer shell and canopy shall be of 2.0mm and inner doors and partitions shall be of 2.0 mm (7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. (8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
Design, supply, erection, testing and commissioning of indoor type LT Panel Board of overall size not less than 1500 mm width x 1000mm Height (Without Base Channel) x 450mm Depth, M.S. Channel (75 MC) Base Frame mounted (to be mounted on the brick. pedestal of height 800 mm above floor level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 200 amps. The Panel Board shall be duly fabricated in a approved / certified factory / fabrication House who posseses type test certificate from CPRI for similar type of Panel Board and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Panel Board shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-52 and general construction conforming to IS : 13947. The Panel Board shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front & rear opening facility with locking facility . The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :- Location : Proposed Sub-Stn Bldg (Change Over Panel))
a) Open execution type on Load Change Over Switch, 125 Amps,4 Pole, Front Operated, Panel Mounting Type,suitable for 3 Phase, 415 Volts, 50 Hz Supply complete including Panel mounted operating handle with door interlock kit, Phase Barrier and necessary connection from Bus Bar by Aluminium strip of suitable size to carry 1.5 times rated current of the change over switch. - 01 No. Make : Havells (Euroload) / L&T / HPL (Socomec) b) Open execution type Automatic Transfer Switch with electronic controller, 125 Amps,4 Pole, Front Operated, Panel Mounting Type, suitable for automatic / manual operation in 3 Phase, 415 Volts, 50 Hz Supply complete including side mounted operating handle with door interlock kit, Phase Barrier and necessary connection from Bus Bar by Aluminium strip of suitable size to carry 1.5 times rated current of the change over switch. - 01 No. (Source-I - 63 KVA AMF Panel & Source-II - 250 KVA AMF Panel) Make : Havells / L&T / Standard INSTRUMENTATION SYSTEM :- a) LED Phase Indicating light, shrouded type, 22mm, with cluster LED suitable for 230 Volts AC - 02 set (Set of 3 lamps RED,YELLOW & BLUE) For source -1 & Source - 2 b) Control MCB 3 Amps SP, 240 Volts AC, 10KA - 06 Nos.
Note : All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. (2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. (3) All the inner / outer doors should have locking facility through castle locks (4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. (5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. (6)The thickness of MS Sheet for outer shell and canopy shall be of 2.0mm and inner doors and partitions shall be of 2.0 mm (7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. (8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
Design, supply, erection, testing and commissioning of wall mounted type indoor type LT Panel Board of overall size not less than 1100 mm width x 1400mm Height x 300mm Depth, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 150 amps, Provision of Spreader link to both incoming & Outgoing MCCBs for termination of cables . The Panel Board shall be duly fabricated in a approved / certified factory / fabrication House who posseses type test certificate from CPRI for similar type of Panel Board and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Panel Board shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-52 and general construction conforming to IS : 13947. The Panel Board shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front & rear opening facility with locking facility . The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :- Location : Proposed SMC Bldg (Power / AC Panel)
INCOMING :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA, Fixed magnetic and having fixed type thermal and magnetic setting Ics = 100% Icu and of rating 100 Amps-01 No. OUTGOINGS :- a) 4 pole MCB ( with panel mounted rotary handle ) having thermal setting from 80% to 100% and of ratings :-40 Amps - 3 Nos ( Power / AC DBs of Gr Floor & First Floor) b) SPN MCB of rating 40 Amps 10 KA - 06 Nos ( Power / AC DBs of Gr Floor & First Floor) INSTRUMENTATION SYSTEM :- a) LED Phase Indicating light, shrouded type, 22mm, with cluster LED suitable for 230 Volts AC - 01 set of 3 lamps (RED,YELLOW & BLUE) b) Control MCB 3 Amps SP, 240 Volts AC, 10KA - 03 Nos.
Note : (1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. (2) All the cable entry / exit will be through bottom / top as per site condition. Necessary gland plate to be provided accordingly in the cable alley. The cables shall be terminated duly glanded with single compression type brass cable gland and bi-metallic cable lugs of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. (3) All the inner / outer doors should have locking facility through castle locks (4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. (5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. (6)The thickness of MS Sheet for outer shell and canopy shall be of 3.15mm and inner doors and partitions shall be of 2.0 mm (7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. (8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
Design , supply ,erection , testing and commissioning of Wall mounting type indoor type LT panel board of overall size not less than 1600mm width x1600 mm height (without base channel)x 400 mm depth , M S channel bas frame mounted (to be mounted on the brick padestal of height 725 mm above floor level),suitable for 3 phase and 4 wire , 415 volt AC supply and having 4 nos aluminium busbar of rating 200 amps , provision of spreader link to both incoming and outgoing MCCBs for termination of cables . The panel board shall be duly fabricated in an approved /certified factory /fabrication house who posesses type test certificate from CPRI for similar type of panel baord and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing , rinsing, de-rusting, rinsing, phosphating , rinsing and passivation followed by powder coated painting (thickness not less than 80 micron ) with approved shade of RAL 7032 (Siemens Gray). The panel baord shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-52 and general construction conforming to IS :13947. The panel board shall be made out of 2.00 mm thick CRCA mild steel sheet and 2.00 mm thick gland plate having compartmentalized construction of individual switchgear and bus bars and having front and rear opening facility and locking facility . The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation . The feeder pillar shall be comprising of the followings :- Location : Proposed SMC bldg (Main lighting panel)
Incoming :- (i) 4 pole MCCB (with panel mounted rotary handle ) having breaking capacity 16 KA , fixed magnetic and adjustable thermal setting from 80% to 100 % and of rating 125 Amps -01 nos Outgoing:- (i) TPN MCB of rating 40 Amps - 12 nos ( lighting BDs of GF and FF) Instrumentation System :- (a) LED phase indicating light , shrouded type , 22mm , with cluster LED suitable for 230 volts AC -01 set of 3 lamps (Red , Yellow and Blue) (b) Control MCB 3 Amps SP, 240 volts AC , 10KA -03 nos (c) Danger notice plate duly written in signal red colour on aluminium plate in english and hindi language and of size not less than 150mmmx100mm -02 nos
Note :- (1) All incoming and outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar . (2) All the cable entry and exit will be through bottom/top as per site condition . Necessary gland plate to be provided accordingly in the cable alley. The cables shall be terminated duly glanded with single compression type brass cable gland and bi-metallic cable lugs of suitable size . Cost of end termination of cable shall be deemed to be included in the cost of feeder pillar. (3)All the inner /outer doors should have locking facility through castle locks. (4) Cost of all civil work for brick padestal , duly plastered shall deemed to be included in the unit rate quoted , no seperate payment shall be allowed for this . (5) The dimention of panel board as mentioned above is tentative . If it is required to be enhanced to accomodate the switchgear and maintaining the gaps as per IE rules , it should be enhanced as per requirement without any extra cost to the department. (6) The thickness of MS sheet for outer shell and canopy shall be 3.15 mm and inner door and partitions shall be of 2.00 mm . (7) The panel board should be designed in such a way that adequate workable space is made available inside every compartment. (8)The drawing of the panel board shall have to be got approved by garrison engineer before starting of fabrication process.
S&F Galvanized steel octagonal pole 7.0 mtr long made of 3.0mm thick hot dip galvanized (thickness 65-70 microns) steel sheet (conforming to grade S355JO) of bottom dia 130/135mm & top dia 70mm and galvanized steel base plate (Fe 410 conforming to IS 226 / IS 2062) of size 200mmx200mmx12mm complete with flush mounted lockable hinged door 500mm long and positioned at 500mm above the base plate & mounting plate for fixing of connector, MCB etc. for connection of loop in / loop out cables. The pole shall be duly fixed on R.C.C. foundation (500mm x 500mm x 1550mm duly reinforced with 4 Nos 12mm dia steel round bar of grade Fe-415 and 8 Nos M.S. Sterrup made of 8mm M.S. round bar and including provision of necessary shuttering etc.) by using 4 Nos 'J' type foundation bolts 0f dia 20mm x 600mm long (EN-8 Grade) complete including 2 Nos 1.5 mtr long 63mm dia PVC flexible pipe, duly embaded in concrete foundation, for cable entry / exit and hot dip galvanized steel street light bracket having 300mm long poletop cover of suitable dia made of 3mm thick hot dip galvanized steel sheet and hot dip galvanized arm (1000mm long) made of 32mm dia light grade M.S. pipe duly welded with the pole cap with stiffner plate and provision of 1 No 30 Amps 4 way bolted type FRP / DMC cable connector and 1 No. SP MCB 3 Amps duly mounted on the mounting plate / DIN channel complete all as specified and as shown in drawing as provided by the OEM.
S&F three core 1100 Volt grade PVC insulated sheathed flexible round cable with 1.5 sqmm multi stranded copper conductor complete and making connection from pole box to street light all as specified and directed.
M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron strip of size 32mm x 6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 40 mm GI tubing medium grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally upto 150mm below ground level , GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results on a 3.0mm thick painted M.S. earth pit marking Plate (200mm x 100mm) duly welded with a 450mm long 10mm dia round M.S. rod, fixed with the earth pit chamber by grouting complete all as specified an directed.
M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron Wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 15 mm GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both ways with MS handle 10mm dia, plastering 15mm thick CM (1:6) internally & externally upto 150mm below ground level , GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing complete all as specified an directed.
M&L for WMM ( Wet Mix macadam) 150 mm thick laid in two layers not exceeding 75 mm thick,each layer (compacted thickness) with mechanical paver as per MORTH specification,spread,rolled and consolidated to gradient and camber as required including necessary lateral support and form work,if required using crused stone aggregate of maximum size 40mm of grading as specified type sedimentary rock such as limestone/sandstone/quartzite etc as base course for paved shoulder etc complete all as specified and directed.
M&L for preparing of new black top surface of road and applying one coat of reflective thermoplastic road marking paint (white or yellow) 2 mm thick for longer durability and paint material shall be conforming to MORTH (Min of surface transport) specification complete all as specified and directed .
Supply and fix Wall mounted Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and having digital display of input and output voltage, time delay relay(3 Min ± 20 Sec), over load protection, Low & High Voltage cutout, and of capacity 2.0 KVA
Supply and fix Wall mounted Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and having digital display of input and output voltage, time delay relay(3 Min ± 20 Sec), over load protection, Low & High Voltage cutout, and of capacity 5.0 KVA
Supply, fix installation ,testing and comissioning of Fully Automatic Reverse Osmosis Plant including all necessary piping and of having following features :- 1) Purification Capacity : 25 Ltrs / Hr 2) Brand : Commercial 3) Operating Voltage : 160V AC -300V AC, 50 Hz (Suitably stepped down to required DC Voltage through adaptor) 4) Provision of Purification : RO + UV + TDS Controller 5) Type of Mounting : Wall mount cum counter-top water purifier 6) Water to be used : From any source like underground / River water / Lake etc. 7)Nos of RO membrane : 2 units (min) 8) Maximum Duty Cycle : 250 Ltrs / day 9) Type of Filter Cartidge : Activated Carbon 10) Stages of purification : 6 (Min) (Pre-filter, activated carbon, RO membrane, Post Carbon,TDS membrane & UV) 11) Minimum inlet Water Pressure : 0.3 Kg / Cm² 12) Total Hardness of inlet water : 500 ppm (max) 13) Total desolved solid (TDS) of inlet water : Upto 2000 ppm 14) Inlet water temparature range : 5°C - 50°C
Supply, install, testing & commissioning traction Hospital goods elevator machine in exiting machine room located directly above lift well, Electrically operated with microprocessor based full simpelx colletive control with/without attendant 1088 Kgs lift suitable to serve G+1 upper floors with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex automatic and manual dual Closed loop controlled operation with/without attendant, telescopic opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set & human interface device(HID). all as specified below :- Note: (i) Contractor to submit detailed construction drawings of lifts being provided with complete technical specifications as per IS: 14665 (including all ammendments up to date) before dispatch of material from OEM for approval of GE. (ii) The lift shall be installed in existing lift well therefore contactor is adivised to visit site for the size of car, door, floor travling hight and left hand/right hand side wall space, existing head room height and pit size before quoting/ordering the fabrication/disigne of lift. (iii) The scope of work also covered the civil work comprising cutting of holes and making good. car and counter weight guide rails and bracket, terminal buffers supports and sill angle, plates and any other items required for successfull completion of lift with respect to safety required by the OEM, will be carried out by contactor without any extra cost.
(iv) The contractor shall be responsible for 02 years DLP from certified date of completion of GE. During the said DLP period the lift,shall be kept functional/serviceable all the time & all consumable items shall be provided by contractor for operation & maintenance of lift. All periodical maintenance regular check up/inspection shall be carried out by OEM during 02 years DLP. In addition to regular checkups and periodical services special visit/inspection will also be carried out to rectify defects by representative of OEM if any emergency / trouble developed.An agreement of will be made between contractor & OEM and this shall be submitted to GE atleast 06 months prior to the isssue of completion for phase-I and II for the comprenssive maintenance of lift. The cost of above shall be deemed to be included in the quoted rates. (v) The provision of suitable steel structure/ palteform for installation of lift equipment is part of lift item and nothing extra shall be paid. (vi) If any clearance required from state goverment i.e. lift inspector/ electrical safety department/ fire safety departments is the contactor's responsibility & any expenditure on this account shall deemed to be included in the quoted rates.
BASIC DATA / TECHNICAL SPECIFICATION (a) Type of Lifts : Goods lift (b) Load & capacity : 1088 Kgs (c) Speed : 1.00 mtr/sec (d) Power Supply : 415 volts, 3 phase AC, 50 Hz (e) Stpos and openings : 2 Stops and 2 openings, Single entrance Car. (f) Travel hight : 2 Floor of hospitall building. (g) Grouping / Operetion : Simplex, Full collective. (h) MAP Floor position : Top most floor. (j) Car size : As per IS and suitable to install in existing lift well of size 2360mm x 2600mm. (k) Door size : 1200 mm wide x 2000 mm height or as per IS and manufacturer specification. (l) Door type : Double entry door (two side opening), Two panel centre opening , telescopic stainless steel with Air vent, automatic operated door. (m) Indicators : Car position indicator car & landing direction and position, indicator with stainless steel fixtures at all floor with dot red led scrolling display. (n) Traction media : Round stranded steel wire rope confirming to IS-14665-2000 or as per manufecturer specification with gaurds. (o) Call register type micro push button for opening and closing of doors.
FINISHES (a) Car design : Stainless steel hair line finish / mirror polished (b) Car panel finish : Mirror polished stst. (c) Hand rail : Round bend hand rail stainless steel at rear wall. (d) Ceiling and lighting : Metallic stain less steel with led light fixtures. (e) Flooring : 20 mm Reecess and granite stone. (f) Car door finish : Stainless steel hairline finish with fire raitng 60 min. (g) Landing door mark : Floor Number - G to 1, Floor mark G,1 Landing door material- Stainless steel hairline finish with fire rating 1 hrs. (h) Car opening panel : Brushed StSt, Tempered glass segmented LED display round flush mounted. (j) Landing signalization : TG, Tempered glass segmented dot red LED scrolling display display flush mounted TG, tempered glass round flush mounted.
STANDARD SAFETY FEATURES/DEVICES (a) Car emergency light, Fireman drive, Curtain of light, Accurate relevelling, Automatic closed door. (b) Emergency rescue device with audio announcer, nudging attendent service, ring lighting LED. (c) Digital direction and position indicator in car and at all landings. (d) Emergency alarm at the main landing with alarm bell button in car. (e) 2 Phase/2 way fire man drive, fire man switch at the main landing.( In case fire man drive is activated the lift will come to the main landing and open the door) (f) Advanced door operation ( To ensure smooth opening and closing of the doors at adjustable door speed) (g) Additional pressure sensing device. (h) Load weighing device ( Audio visual over load indicator in the car for better safety) (j) Full height infra-red curtain ( Highly sensitive safty device for safe entrance and exit of the passangers in to the car). (k) Pit ladder ( To ensure safety of the maintenance personnel). (l) Emergency light, Intercom and alarm with maintenance free rechargable battery operation ( To ensure passenger comfort and safety in case of emergency)
(m) Over speed governor ( Electro mechenical device that prevents free fall in case the elevator is travelling at speed more than 10 % of the rated speed in down ward direction)(n) Automatic rescue device ( To rescue the passengers in case of emergency, the device will bring the car to the nearest floor automatically and will open the doors). (o) Special car door lock, Automatic daily brake testing, Latest technology motor-PMS, Touch panel with LED display. (p) Mechanical rescue device with no dependence with battery. (q) Cross flow fan, 2 way built in communication system, anti nuisance car call protection. (r) Door time protection with extra door time for lobby and parking, auto fan cut off. (s) Mirror on rear side wall and voice synthesizer. (t) Controller shall be include protection against over current,over voltage, single phasing, phase reversal, earth leakage and interlocking with door opening, closing and moment of lift and any other operation required for the safety of passenger as per fire safety regulation pertainging to lift. (u) Emergancy stop button with alarm. (v) Two position key operated switch with attended and without attended switch mode. (w) Any other accessories / safety device required as per IS for safety of passengers.
Material and Labour for annual maintenance of G+1, 1088 Kg goods lift installed under item no. 15.39 to 15.44 Above by performing all fortnightly, monthly, bi-monthly, half yearly and yearly checks and tests, including repair and replacement of unserviceable spare parts (Labour only) for making serviceable after the completion of defects liability period (DLP) through OEM all as specified and directed. Note :- (a) The Contractor shall enter into a MOU with the OEMs for the provision of the lift and further maintenance . The MOU for post warranty /post defect liability period between the contractor and OEM shall be submitted. (b) The rate quoted is inclusive of all consumable and minor parts but excluding of spare parts . If there is any requirement of major spare parts , the same will be procured by the contractor and paid by the deptt under PC sum .
For First year after DLP
For Second year after DLP
For Third year after DLP
Supply, install, testing & commissioning traction Hospital Streacher elevator machine in exiting machine room located directly above lift well, Electrically operated with microprocessor based full simpelx colletive control with/without attendant 15 Passangers/1020 Kgs lift suitable to serve G+1 upper floors with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex automatic and manual dual Closed loop controlled operation with/without attendant, telescopic opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set & human interface device(HID). all as specified below :- Note: (i) Contractor to submit detailed construction drawings of lifts being provided with complete technical specifications as per IS: 14665 (including all ammendments up to date) before dispatch of material from OEM for approval of GE. (ii) The lift shall be installed in existing lift well therefore contactor is adivised to visit site for the size of car, door, floor travling hight and left hand/right hand side wall space, existing head room height and pit size before quoting/ordering the fabrication/disigne of lift.
(iii) The scope of work also covered the civil work comprising cutting of holes and making good. car and counter weight guide rails and bracket, terminal buffers supports and sill angle, plates and any other items required for successfull completion of lift with respect to safety required by the OEM, will be carried out by contactor without any extra cost. (iv) The contractor shall be responsible for 02 years DLP from certified date of completion of GE. During the said DLP period the lift,shall be kept functional/serviceable all the time & all consumable items shall be provided by contractor for operation & maintenance of lift. All periodical maintenance regular check up/inspection shall be carried out by OEM during 02 years DLP period .In addition to regular checkups and periodical services special visit/inspection will also be carried out to rectify defects by representative of OEM if any emergency / trouble developed.An agreement will be made between contractor & OEM and this shall be submitted to GE atleast 06 months prior to the issue of completion for Phase-I and II for the comprenssive maintenance of lift. The cost of above shall be deemed to be included in the quoted rates. (v) The provision of suitable steel structure/ palteform for installation of lift equipment is part of lift item and nothing extra shall be paid. (vi) If any clearance required from state goverment i.e. lift inspector/ electrical safety department/ fire safety departments is the contactor's responsibility & any expenditure on this account shall deemed to be included in the quoted rates.
BASIC DATA / TECHNICAL SPECIFICATION (a) Type of Lifts : Hospital Streacher machine (b) Load & capacity : 1020 Kgs (c) Speed : 0.5 mtr/sec (d) Power Supply : 415 volts, 3 phase AC, 50 Hz (e) Stpos and openings : 2 Stops and 2 openings, Single entrance Car. (f) Travel hight : 2 Floor of hospitall building. (g) Grouping / Operetion : Simplex, Full collective. (h) MAP Floor position : Top most floor. (j) Car size : As per IS and suitable to install in existing lift well of size 3095mm x 1800mm. (k) Door size : As per IS and manufacturer specification. (l) Door type : Two- panel Centre opening , telescopic stainless steel with Air vent, automatic operated door. (m) Indicators : Car position indicator car & landing direction and position, indicator with stainless steel fixtures at all floor with dot red led scrolling display. (n) Traction media : Round stranded steel wire rope confirming to IS-14665-2000 or as per manufecturer specification with gaurds. (o) Call register type micro push button for opening and closing of doors.
STANDARD SAFETY FEATURES/DEVICES (a) Car emergency light, Fireman drive, Curtain of light, Accurate relevelling, Automatic closed door. (b) Emergency rescue device with audio announcer, nudging attendent service, ring lighting LED. (c) Digital direction and position indicator in car and at all landings. (d) Emergency alarm at the main landing with alarm bell button in car. (e) 2 Phase/2 way fire man drive, fire man switch at the main landing.( In case fire man drive is activated the lift will come to the main landing and open the door) (f) Advanced door operation ( To ensure smooth opening and closing of the doors at adjustable door speed) (g) Additional pressure sensing device. (h) Load weighing device ( Audio visual over load indicator in the car for better safety) (j) Full height infra-red curtain ( Highly sensitive safty device for safe entrance and exit of the passangers in to the car). (k) Pit ladder ( To ensure safety of the maintenance personnel). (l) Emergency light, Intercom and alarm with maintenance free rechargable battery operation ( To ensure passenger comfort and safety in case of emergency)
(m) Over speed governor ( Electro mechenical device that prevents free fall in case the elevator is travelling at speed more than 10 % of the rated speed in down ward direction) (n) Automatic rescue device ( To rescue the passengers in case of emergency, the device will bring the car to the nearest floor automatically and will open the doors). (o) Special car door lock, Automatic daily brake testing, Latest technology motor-PMS, Touch panel with LED display. (p) Mechanical rescue device with no dependence with battery. (q) Cross flow fan, 2 way built in communication system, anti nuisance car call protection. (r) Door time protection with extra door time for lobby and parking, auto fan cut off. (s) Mirror on rear side wall and voice synthesizer. (t) Controller shall be include protection against over current,over voltage, single phasing, phase reversal, earth leakage and interlocking with door opening, closing and moment of lift and any other operation required for the safety of passenger as per fire safety regulation pertainging to lift. (u) Emergancy stop button with alarm. (v) Two position key operated switch with attended and without attended switch mode. (w) Any other accessories / safety device required as per IS for safety of passengers.
Material and Labour for annual maintenance of G+1, 15 passengers (1020 Kg) passengers lift installed under item no. 15.49 to 15.53 Above by performing all fortnightly, monthly, bi-monthly, half yearly and yearly checks and tests, including repair and replacement of unserviceable spare parts (Labour only) for making serviceable after the completion of defects liability period (DLP) through OEM all as specified and directed. Note :- (a) The Contractor shall enter into a MOU with the OEMs for the provision of the lift and further maintenance . The MOU for post warranty /post defect liability period between the contractor and OEM shall be submitted. (b) The rate quoted is inclusive of all consumable and minor parts but excluding of spare parts . If there is any requirement of major spare parts , the same will be procured by the contractor and paid by the deptt under PC sum .
For First year after DLP
For Second year after DLP
For Third year after DLP
Supply, installation, commissioning and testing complete Silent Diesel Engine driven Generating Set microprocessor based controller 1500 RPM of capacity 250 KVA (200KW) (or nearest higher rating) AC volts. 50 C/s. 3 phase. 4 wire. 415 volt. 0.8 PF complete with standard control panel and AMF Panel as per OEM's recommendations including integrated power coated acoustic elclosure as per CPCB norms circulated in the year 2020 and duly certified by agencies / lab designed by CPCB for noise level upto 75 dbA at one' meter distance etc floor mounted including PCC foundation as per manufacturer's specification complete all as specified and directed and comprising of the following :- (A) DIESEL ENGINE : Turbo charged Diesel Engine suitable for capable to deliver adequete power to r drive the alternator to produce necessary power at rated power factor. The engine shall be multi cylinder, vertical type. 4 stroke. water cooled. electric battery start confirming to IS 10001/10002/BS - 5514 for continious runningfor 12 Hours and capable of taking 10% overload for one hour in 12 hours testing period complete and comprising the following (i) Radiator cooling including coolant (ii) Radiator fan with guard (iii) Fly wheel with starting relay. (iv) Air cleaner oil bath type. (v) vaccum indicator . (vi) Electronic governer class 1A.
(vii) Exhaust silencer with retrofit pollution control device to control the emission level as per the latest specified limit by CPCB (NOx+HC ≤4.0 g/kw-hr , CO ≤3.5 g/kw-hr, PM ≤ 0.2 g/kw-hr & Smoke limit (light absorption coefficient ≤ 0.7 m-1)) (viii) Fuel filter and fuel hoses. (ix) Fuel injector pump. (x) Fan and water pump assy. (xi) Lub oil filter and pump (xii) Oil filter (xiii) Turbo charger . (xiv) Lub oil cooler. (xv) Engine maintenance mannual with spare parts list . (xvi) Suitable design acoustic enclosure stop switch. (xvii) Engine Energy stop switch (xviii) Engine safety shut down system against low lub oil pressure and high water pressure (xix) Electric battery starting system with barttery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 12 volts and suitable Ah as recommendation by the OEM including interconnecting cables/leads with terminals complete - 01 set. Note Any other component which are left out in the above list, but esentially required as per OEM's design , shall be provided without any extra cost.
(B) ENGINE INSTRUMENT PANEL : It shall be consisting of the following :- (i) Starting switch ON / OFF (ii) Water temperature guage. (iii) Hours Run meter (iv) RPM indicator (v) Lub oil pressure guage. (vi) Frequency meter. (vii) Battery charging meter. (viii) Safety alarm against high water temp and low / high lub oil pressure. (C) ALTERNATOR:- It shall be Self exciting, self regulated, drip proof, brush less alternator rated for 250 KVA continuous operated at the speed of 1500 RPM at 415 volt, 50 Hz, three phase, four wire system with automatic voltage regulator to ensure high voltage accuracy within +1% with class 'H' insulation and SPDP enclosure directly coupled with engine though flexible coupling and comforming to IS : 13364. complete 01 No (D) BASE FRAME : A common base frame, fabricated with structural steel for eingine and alternature including adequate number of suitable dunlop metallastik anti-vibration pads all as per recommendation by the manufacturer.
(E) FUEL TANK : Fuel tank shall be fabricated out of 2mm thick MS Sheet of capacity to store fuel for one day reserve and shall be mounted inside the canopy. Capacity of the tank shall not be less than 8 hrs continious operation. It should have contain fuel lavel gauage, drain plug, locking arrangement etc with and including pipe connections duly laid as per engineering practice complete. (F) DOCUMENTS : Operation and maintenance mannual book, spare parts list, Warranty card of Battery, Test Report of Engine & Alternator etc. shall have to be supplied by the contractor alongwith the DG Set. (G) AMF Panel : Supply installation, commissioning & testing for microprocessor based AMF control panel indoor type suitable for 250 KVA DG set, with and including internal wiring , floor mounted type, totally enclosed made out of MS CRCA sheet, 2.0 mm thick and applying two coat of powder coated epoxy paint (RAL-7032) of approved shade after necessary surface treatment complete all as specified and directed. The panel shall be of suitable shape / size & design as approved by Engr- in charge with following accessories:- (i) MCCB, 04 pole current rating of 400 amps and ultimate breaking capacity ICU 36 for 415 volts, 03 phase AC. supply. 02 Nos (Mains & DG Supply) (ii) Three pole power contactor with standard coil voltage of 415 volts 50 Hz and auxiliary contact of 02 Nos having AC three phase rating of 400 amps - 02 Nos.
Note for AMF Panel :- Any other component which are left out in the above list, but essentialiy required as per OEM's design, shall be provided without any extra cost. General Note :- (a) Cost of suitable size PCC foundation is deemed to be included in the unit rate quoted by the contractor. (b) Cost of fuel (for 12 hrs testing on various loads as specified in PS) and hire charges of artificial load alongwith other testing materials are deemed to be include in the unit rate quoted. No extra charges shall be paid for this. (c) If it is required to extended the exhaust pipe outside the room, it shall be done with additional pipe having same specification of existing exhaust pipe including all jointing materials. Cost of the additional pipe is deemed to be included in the quoted rate. No extra payment shall be allowed for the same.
(vi) SMPS battery charger with auto/trickle/boost/off comprising of transformer, rectifier, auto voltage card complete. (vii) Audio/Video annunciation for high water temerature, low lubricating oil lubricating oil pressure, engine over speed, Engine fails to start, full load/maximum load warning etc. (viii) PVC Insulated copper conductor multicore control cable of adequate size from AMF panel to diesel engine and elsewhere. (ix) Energy stop switch. (x) Mico processer control self operated over current and earth fault relay with instantanteneous setting including CTs of class 5P10 of suitable capacity for protection and metering complete all as specified. Note :- Any other component which are left out in the above list, but essentialiy required as per OEM's design, shall be provided without any extra cost.
Dismantaling of Existing serviciable DG Set of capacity 63 KVA including Disconnectiong electric connection / earthings from Alternator and shifting safely at a distance not excceding 100 Mtr (Appx) at new loction and making electric connection and PCC foundation Suitable for the DG set complete all as specified and directed.
Drawing out old submain copper/aluminium cable off various sizes from existing conduit/ batten complete all as specified and directed.
Taking down old MCB DB all type including MCB complete all as specifie and as directed.
Taking down carefully existing ceiling fan, wall fan and exhaust fan of any size complete without damaging and transporting to MES store for safe custody complete all as specified and as directed.
Taking down carefully existing geyser of any capacity without damaging and transporting to MES store for safe custody complete all as specified and as directed.
Taking down carefully existing air conditioner of any capacity without damaging and transporting to MES store for safe custody complete all as specified and as directed.
Sch A Part XVI (SCHEDULE OF CREDIT) Schedule of Credit B/F from Serial Page No. 63(R) will be automatically deducted to arrive at tendered sum. [Note : Details of items for schedule of credit is given on Srl Page No.63(R).
Sch A Part XVII (PRIME COST SUM)
Lump sum price worked out by the contractor for Prime Cost sum as listed in Sch ‘A’ Part XVII. Note :- The amount to be quoted by the tenderer in BoQ inserted by the department shall be restricted to MAXIMUM 15 % over and above the prime cost sum .Accordingly, the tenderer shall quote the amount.
Pooja Singla Builders And Engineers Pvt Ltd
Global Enterprises
City Promoter and Buildwell Pvt. Ltd.
Sudhir Sharma Associates
J.D.Builders
SAWHNEY BUILDWELL LLP
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .