| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹88.7 LAccepted-AOC C O NEPAL DEBNATH SANTINAGAR W NO 3 P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | ₹88.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹88.7 L+₹280 (<0.01%)Rejected-Finance | ₹88.7 L+₹280 (<0.01%) | L2 | Rejected-Finance QUOTED HIGH |
| 3 | L3₹88.7 L+₹1,565.90 (0.02%)Rejected-Finance WARD NO 5 TENGAPARA P O P S DIST KOKRAJHAR PIN 783370 | KOKRAJHAR | ASSAM | 783370 | ₹88.7 L+₹1,565.90 (0.02%) | L3 | Rejected-Finance QUOTED HIGHEST |
Tender Value
₹88.7 L
EMD Value
₹1.8 L
Closing Date
14 Feb 2020, 3:00 pmClosed
SE PWD(R and B) Circle, Kokrajhar
O/o the SE PWD(R and B) Circle, Kokrajhar
Construction and Installation of 10 passenger lift machine 2 Nos. to Bineswar Brahma Engineering College, Kokrajhar, Assam (Construction of RCC wall and machine room) under SOPD-G during the year 2019-20.
2020_BoTC_16133_1
TN 148 of 2019-20 148/2
Open Tender
Civil Works
Works
365 days
Kokrajhar
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,700
Principal Secretary, BTC
₹1.8 L
Yes
2 May 2021
29 Jan 2020
14 Feb 2020
29 Jan 2020
14 Feb 2020
29 Jan 2020
29 Jan 2020 - 14 Feb 2020
Amount
(A) Construction of RCC Wall and Machine Room 2 Nos.: Earth work in excavation in foundation trenches of wall, footing and column, steps and septic tank etc. including refiling the quantity as necessary............as spedified. (A) Up to depth of 2.0 m Ground Level (b) In Ordinary Soil.
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Plain cement concrete work with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified...........complete. (c) In prop 1:3:6
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land........................as may be necessary. (C) With river sand or silt.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per............... etc. complete. (ii) Super Ductile (SD) bar
Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from....................and paid separately. (i) Using Mixer Machine. (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam...................... plinth level. b) M-20 or Prop. 1:2:4
Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from....................and paid separately. (i) Using Mixer Machine. (b) In Super-Structure from plinth level up to 1st floor level. (ii) Column, pillar post................................of noising. (N) With out admixture, Plasticiser. b) M-20 or Prop. 1:1.5:3
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in Sub-Structure upto plinth level. (i) In slab structure. (c) In prop 1:5
1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level. (A) In cement mortar 1:4
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting..........concrete work in. 3.2.1.1 Column, pillar, post & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc. having plan vertical face.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting..........concrete work in. 3.2.1.2. Side and soffts of beam haunchings, cantilever girder, bressumers, lintel & horizontal ties. (a) For depth not exceeding 1.0M
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting..........concrete work in. 3.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas,balconies and the like. (a) Floors etc. upto 200mm in thickness.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting..........concrete work in. 3.2.1.6. Vertical surface such as walls (any thickness) parapet walls, partitions and the like including attached pilasters, brtresses, plinth and string course and the like.
Plain cement concrete floors base in prop 1:3:6 laid in alternate bays as specified with coarse agg.of size 13mm to 32mm including dewatering if necessary, and curing etc complete (b) 50mm
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 corse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick.
Providing Antiskid Tiles of approved quality size shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile..............directed. 5.11.2 VITRIFIED i) Executivel range
15mm thick cement plaster in single coat on rough side of single half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A. On fair side b. In cement 1:4
Structural steel work in single sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint (up to 4.6m height) from plinth level including drilling holes, supplying fitting and fixing with bolts and nuts or welding if necessary as directed.
(a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surfaces free from mortar droppings and other..........smooth.
(b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface to give an even shade after thoughly brooming the surfaces to remove all dirt and remains of loose powered materials.
Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of shade after cleaning the surface etc.including scaffolding complete as directed at all levels (two coats)
Providing galvd iron ridging of TATA SHAKTEE SAL including supplying and fixing necessary galvd crews/washers etc. complete as directed. (a) Cement concrete 1:2:4
Extra over item Nos. 2.2.1 (I) (B) above for each subsequent floor or part thereof above the 1st floor level. For 1st floor
Extra over item Nos. 2.2.1 (I) (B) above for each subsequent floor or part thereof above the 1st floor level. For 2nd floor
Extra for each subsequent floor or post.......... For 1st floor
Extra for each subsequent floor or post.......... For 2nd floor
Extra for brick walling for each sbsequent floor or part thereof above the 1st floor level (a) 112mm wall. (a) For 2nd floor
Extra for plastering..............directed. (a) On single plaster. For 1st floor
Extra for plastering..............directed. (a) On single plaster. For 2nd floor
Extra over item 18.1.1 (a,b,c) for 1539.00 each............level For 1st floor.
Extra over item 18.1.1 (a,b,c) for 1539.00 each............level For 2nd floor.
(B) Electrification work: Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/ Presto /Polycab/ make as approved by the Deptt.) in surface system including 6 Amp flush type switch/ bell push (Anchor /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose push (Anchor /Gold medal /Kolor kany.Kom/Havells or equivalent as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.1 Short point up to 3.00 metre. length.
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/ Presto /Polycab/ make as approved by the Deptt.) in surface system including 6 Amp flush type switch/ bell push (Anchor /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose push (Anchor /Gold medal /Kolor kany.Kom/Havells or equivalent as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.2 Medium point up to 6.00 metre. length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ make as approved by the Deptt.) system including earth continuity. 1.8.1 With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in flat 19 mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ make as approved by the Deptt.) system including earth continuity. 1.8.2 With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. in flat 19 mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR Conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Make as approved by the Deptt.) in surface flat ISI market casing n' capping (AKG/Precision/ Presto/Polycab/make as approved by the Deptt.) system including earth continuity. 1.10.4 With 4 x 10 sq. mm + earth continuity with 2 x 6 sq. mm in flat 32 mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR Conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Make as approved by the Deptt.) in surface flat ISI market casing n' capping (AKG/Precision/ Presto/Polycab/make as approved by the Deptt.) system including earth continuity. 1.9.5 With 3 x 116 sq. mm + earth continuity with 2 x 10 sq. mm in flat 19 mm ISI marked casing 'n' capping system.
Wiring to 5 pin 6 Amps plug point with 1.5 sq.mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR Conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to annealed electronic coper conductor for voltage grade upto 1100V (Finolex/RR cable or Equivalent Make as approved by the Deptt.) including providing & fixing 5 pin 6 AMP socket outlet (Anchor /penta/Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) and 6 AMP flush type switch (Anchor/penta/Gold Medel/Kolor/Kany/Havells or equivalent make as approved by the deptt.) earthing the 3rd pin of the socket as required on the switch board in flat ISI marked casing 'n' capping when fitted on same board of light and fan.
Supplying and fixing of polished Brass Bracket of 18.S.W.G 25cm, long cast back plate and brass lamp holder complete including connection as approved by the deptt. As required (without lamp)
Moster PL-C 18 W/840/4R/29
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust vermin proof double door (Id-43) surface mounting SPN MCB DB incorporated with bas-bar Netural link, Earth bar and din railt etc fitted on wall with grounting nuts & bolts as req. complete with making necessary connection as approved and specified and directed by the deptt. 15.4.1 (Schneider neo break, C & S, Havells, Standard, or equivalent as approved by the deptt.) 15.4.1.1 4 way SPN double door.
Supplying with fitting and fixing sheet steel phosphatised powder painted single door-surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth wire able etc. fitted on wall with grounting nuts & bolts as reqd. complete with making necesssary connecting as approved the deptt. 15.7.1 ABB Schneider MG, Legrand, Xpro, Standerd or equivalent as approved by the deptt. 15.7.1.1 4 way TPN (4+12) single door
Supplying with fitting and fixing 4P 10 KA 415V 50Hz MCB of the following capacity complete with making necessary connection as approved by the deptt. B-Series (ABB, Scheider MG, Legrand, Hanger, Crabtree Xpro make) 16.6.1.3 63A
Supply installation & testing of G.I earth station with perforated 40 mm dia and 4.50 mtr long heavy duty G.I pipe with necessary 40 mm dia. G.I. Fitting such as Socket, tee, elbow, nipple and 50mm x 40mm G.I. reducing socket for funnel including locking arrangement 300mm x 300mm x 6mm hinged cover C.I earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner of outer surface of wall as specified and directed by the deptt.
Extra for using salt 5 K and Charcoal 64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 8 SWG Copper. Earth from Earth Electrode (below G.L) to electrical switch gears or electrical machineries including making necessary connection as approved specified and directed by the deptt.
LHOT 01/28632x1x28WT5FTL Havells or equivalent as approved.
Supplying including fitting fixing of following A.C. exhaust fan in the existing hole on the wall following sweeps with making necessary connection as approved by the deptt. as required complete and as directed by the Department. 27.2.1 Domestic 27.2.1.2. Power flux 225mm sweep (Orinet make)
Other Features-Battery Operated Emergency Alam & light OSG electronic Switch, Call registration LEDS 2 station Intercom system infra red light curtain door safety resque Divice lift Announcement.
SRI BISWAJIT LODH ROY
GAUTAM BRAHMA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .