Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.4 LAccepted-AOC 315 KUMARAN NAGAR MAIN ROAD NATHAM KUNRATHUR KANCHIPURAM TAMIL NADU 600069 | KANCHIPURAM | TAMIL NADU | 600069 | 1 | Accepted-AOC Accepted | |
| 2 | 2₹9.6 L+₹1.2 L (14.5%)Rejected-AOC 111 2 SENTHIL NAGAR 100 FEET ROAD ARUMBAKKAM CHENNAI TAMIL NADU 600106 | CHENNAI | TAMIL NADU | 600106 | 2 | Rejected-AOC Accepted |
Tender Value
₹9.8 L
EMD Value
₹19,670
Closing Date
23 May 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Head, ESD
CSIR - NIIST, Trivandrum
Setting up Semi-Clean Room cum Dark Room Facility in Room No 320 (Main Building-First Floor) for MSTD in NIIST Campus, Trivandrum
2022_CSIR_115054_1
NIIST/ESD-C/WKS/65/1-4/2022-23
Open Tender
Civil Works
Item Rate
60 days
CSIR-NIIST, Trivandrum
As per NIT
13 documents required · 13 mandatory
₹590
The Director, CSIR - NIIST
₹19,670
15 Jun 2022
13 May 2022
24 May 2022
13 May 2022
23 May 2022
13 May 2022
90 days
Amount
WALL / CEILING PANELS
Supplying and Fixing Prefabricated Double Skin Panel 80mm thick made of 0.6mm thick PPGI sheets on both sides with EPS (Thermocole – TF-Fire retardant grade) core, all joints duly sealed, with conduits as provision for wiring and complete with accessories such as floor track, fasteners, supports, scratch guardfilm, silicone sealant, cutouts for electrical sockets, View Panel etc. (Colour shall be decided by the Engineer-in-charge)
Supplying and Fixing Prefabricated Double Skin Panel 50mm thick made of 0.6mm thick PPGI sheets on both sides with EPS (Thermocole – TF-Fire retardant grade) core, all joints duly sealed, with conduits as provision for wiring and complete with accessories such as necessary accessories like tuen buckles,theared rods ,nut and bolts,t- grid, fasteners, supports, scratch guardfilm, silicone sealant, cutouts for electrical sockets, View Panel etc. (Colour shall be decided by the Engineer-in-charge)
Coving: Aluminium powder coated section (2” radius) to round off 90º joints between wall-wall, wall-floor, wall-ceiling in the same colour as the Panels, backed with aluminium clip-on angle & finished with Silicone sealant.
3D Corners - Supplying and fixing of 3D corners on all exposed corners with suitable material and matching with the wall / ceiling panel colour, backed with clip on angle & finished with silicone sealent.
C-Cap - Supply and Installation of C-Cap for covering cutouts of lighs, module, doors etc as per the manufacturer specification.
Clean Room Hinged Doors : Metallic scientific doors with double glazed view panel of size 450 X 750 mm with 5mm thick glass; door closer, SS handle etc.Size:1.0m X 2.1m
Clean Room Hinged Doors : Metallic scientific doors with double glazed view panel of size 450 X 750 mm with 5mm thick glass; door closer, SS handle etc.Size:Maintenance Door Double Door for Equipment Service Size:1.8m X 2.1m
FLOORING
Epoxy flooring: Self leveling , seamless floor using 2-component system with suitable surface preparation 2mm total thickness
AIR SHOWERS
Supply & Installation of Air Shower shall be a high velocity, low pressure type system in accordance with Federal Standard 209E and Air Force Tech Order 00-25-203.The Air Shower design will provide normal entrance to and exit from a contamination controlled area. The Air Shower shall be a completely self contained unit, equipped with air filtration systems, blowers, motors, controls, solid-state programmable microprocessor, interlocking doors with view panels, lighting, and pre-wired electrical panel All exterior and interior Air Shower surfaces shall be completely sealed with materials compatible with Class ISO 5 Adjustable air nozzles shall be white SS construction sized and spaced to provide average 5,000 fpm air flow at the face of the nozzle. Return air registers suckes from bottom with return air grilles, built into the Air Shower system's walls. Interior ceilings shall include an appropriate number of air nozzles and a fluorescent light, or HEPA filters and lighting above a protective grille (on models with laminar flow ceilings). HEPA filters capable of emoving 99.99% of dust particles to 0.3 microns in size shall be used. Filter access is from above unit, or as specified. . Replaceable pre-filters of 30% efficiency shall be used to maximize life of the absolute filters and shall be accessible from Air Shower interior, within return air grille(s) - Size of working area shall be 1200x1000x2000mm
Clean Air Systems
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .