Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L3₹66,198+₹6,868 (11.6%)Qualified Make: BPE
Model: BPE 1KVA OFFLINE UPS 19 103 NEW MALHAR SAHARA STATES JANKIPURAM LUCKNOW UTTAR PRADESH 226021 | LUCKNOW | UTTAR PRADESH | 226021 | Make: BPE
Model: BPE 1KVA OFFLINE UPS | L3 | Qualified | |
| 2 | L4₹66,300+₹6,970 (11.7%)Qualified Make: KEPTRON
Model: KEPTRON-KE LI 01-216 H PARK LUCKNOW UTTAR PRADESH 226006 INDIA | LUCKNOW | UTTAR PRADESH | 226006 | Make: KEPTRON
Model: KEPTRON-KE LI 01-216 | L4 | Qualified | |
| 3 | Qualified Make: NPS
Model: COMPANION-1000-216 GROUND FLOOR C 10 VIGYANPURI MAHANAGAR EXTENSION LUCKNOW UTTAR PRADESH 226006 UDYAM UP 50 0008785 09AADCN3125F1ZQ B R M B MII STATUS AS VERIFIED | LUCKNOW | UTTAR PRADESH | 226006 | Make: NPS
Model: COMPANION-1000-216 | - | Qualified | |
| 4 | Qualified Make: VSM
Model: VENUS 1000-216 1ST FLOOR XVI 435 445 AND 482 486 PLOT NO 37 BD BLOCK NEAR GALI NO 14 FAIZ ROAD KAROL BAGH CENTRAL DELHI DELHI 110005 | CENTRAL DELHI | DELHI | 110005 | Make: VSM
Model: VENUS 1000-216 | - | Qualified | |
| 5 | L1₹59,330Disqualified Make: PARADYNE
Model: pdfn3-1000 CENTRAL DELHI DELHI 110005 | CENTRAL DELHI | DELHI | 110005 | Make: PARADYNE
Model: pdfn3-1000 | L1 | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
18 May 2018, 3:00 pmClosed
Line Intractive UPS with AVR Experience with Gov. Required 5 Year (s) Line Intractive UPS With AVR ( 17 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/216 1.0216 Technology MOSFET-PWM MOSFET-PWM
IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single Phase Quasi-Sin- wave 230 V AC
50 Hz Single phase sinewave 230v AC
50Hz
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP-21 IP-21
IP 20 Inverter Efficiency (%) >/= 70% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year
2 Years
5 Years Installation and commissioning instructions Yes - CONSTRUCTIONAL Type of enclosure Mild steel - 1/4 AC out put for printer (not through inverter) No Yes
No Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - 2/4 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date NTH(SR)/EL(C)/2014/24 9C dtd 14.08.2014 - Name Of Lab NTH - Address of Lab Taramani
Chennai - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sunil Dagar 342001
603 (I) Aviation Brigade
Jodhpur (Rajasthan) 17 15 EMD Required No ePBG Required No
68279
GEM/2018/B/9738
Line Intractive UPS with AVR
15 days
Rajasthan; Jodhpur
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Experience with Gov. Required 5 Year (s) Line Intractive UPS With AVR ( 17 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/216 1.0216 Technology MOSFET-PWM MOSFET-PWM | - | - | - |
| IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single Phase Quasi-Sin- wave 230 V AC | - | - | - |
| 50 Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP-21 IP-21 | - | - | - |
| IP 20 Inverter Efficiency (%) >/= 70% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years Installation and commissioning instructions Yes - CONSTRUCTIONAL Type of enclosure Mild steel - 1/4 AC out put for printer (not through inverter) No Yes | - | - | - |
| No Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - 2/4 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date NTH(SR)/EL(C)/2014/24 9C dtd 14.08.2014 - Name Of Lab NTH - Address of Lab Taramani | - | - | - |
| Chennai - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sunil Dagar 342001 | - | - | - |
| 603 (I) Aviation Brigade | - | - | - |
| Jodhpur (Rajasthan) 17 15 EMD Required No ePBG Required No | - | - | - |
Exempted
18 May 2018
8 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_68279.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .