Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC A S NIVAS CHANKURTHY ADAIKKAKUZHI P O KANYAKUMARI DISTRICT TAMIL NADU 629153 | KANYAKUMARI | KANYAKUMARI | TAMIL NADU | 629153 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.0 L+₹60,528 (3.70%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹19.7 L+₹3.3 L (20.4%)Rejected-Finance JOY VILA MRA 230 MOOLAVILKOM JUNCTION VANCHIYOOR TRIVANDRUM 695 035 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695035 | L3 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | SUJAN L1 | SUPER COOL L2 | S L ELECTRICAL WORKS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials from site after accounting in credit schedule and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. | 443 | Per Point | 25 ₹11,075 | 10 ₹4,430 Lowest | 25 ₹11,075 |
| 2.00 | M&L for point wiring complete for one light point controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multistranded, copper conductor through PVC casing and capping 20/ 25 mm size with accessories with sunk iron pressed steel terminal box for fitting mounting switches, sockets, fan regulators etc, with laminated sheet 3mm thick cover including provision of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, unsheathed, 1100 volt grade, multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as specified and directed. | 263 | Per Point | 660 ₹1,73,580 | 450 ₹1,18,350 Lowest | 750 ₹1,97,250 |
| 3.00 | All as per SI item No. 2.00 here-in-before, but for one fan point controlled by one way switch complete all as specified and directed. | 40 | Per Point | 650 ₹26,000 | 480 ₹19,200 Lowest | 800 ₹32,000 |
| 4.00 | All as per SI item No. 2.00 here-in-before, but for one exhaust fan point controlled by one way switch complete all as specified and directed. | 20 | Per Point | 550 ₹11,000 | 480 ₹9,600 Lowest | 830 ₹16,600 |
| 5.00 | All as per SI item No. 2.00 here-in-before, but for one 3 pin socket outlet, 5 Amps, single pole on the same board with other switches including continuous 1.5 Sqmm PVC insulated copper conductor earth wire to common wire earth and connecting to earth dolly all as specified and directed. | 60 | Per Point | 300 ₹18,000 Lowest | 350 ₹21,000 | 300 ₹18,000 Lowest |
| 6.00 | All as per SI item No. 2.00 here-in-before, but for one 3 pin socket outlet, 15 Amps, independent, with cables 4.00 sq. mm size sheathed stranded 1100 Volt grade complete with 4.00 Sqmm PVC insulated earth wire and connecting to earth dolly all as specified and directed. | 20 | Per Point | 850 ₹17,000 Lowest | 900 ₹18,000 | 850 ₹17,000 Lowest |
| 7.00 | All as per SI item No. 2.00 here-in-before, but for one 5 Amp, 3 pin socket outlet on independent board all as specified and directed. | 30 | Per Point | 850 ₹25,500 | 900 ₹27,000 | 750 ₹22,500 Lowest |
| 8.00 | All as per SI item No. 2.00 here-in-before, but for One bell/ buzzer point controlled by one 5 Amps bell push button complete all as specified and directed. | 10 | Per Point | 850 ₹8,500 | 350 ₹3,500 Lowest | 750 ₹7,500 |
| 9.00 | S&F switch piano, flush type single pole, one way 6 Amp complete all as specified and directed. | 323 | Each | 35 ₹11,305 | 20 ₹6,460 Lowest | 45 ₹14,535 |
| 10.00 | S&F switch socket combination multi purpose 5 pin 5/6 Amp flush type complete all as specified and directed. | 90 | Each | 50 ₹4,500 Lowest | 98 ₹8,820 | 60 ₹5,400 |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
26 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum- 695006
REPAIR/MAINT OF INTERNAL WIRING IN OR ACCN AND REPAIR/MAINT OF COOLING APPLIANCES AT PANGODE MIL STN UNDER GE (ARMY) TRIVANDRUM
2025_MES_724071_1
8293/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Trivandrum
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Army Trivandrum
₹46,000
Yes
15 Oct 2025
1 Aug 2025
30 Aug 2025
1 Aug 2025
26 Aug 2025
14 Aug 2025
1 Aug 2025 - 7 Aug 2025
Amount
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials from site after accounting in credit schedule and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for point wiring complete for one light point controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multistranded, copper conductor through PVC casing and capping 20/ 25 mm size with accessories with sunk iron pressed steel terminal box for fitting mounting switches, sockets, fan regulators etc, with laminated sheet 3mm thick cover including provision of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, unsheathed, 1100 volt grade, multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as specified and directed.
All as per SI item No. 2.00 here-in-before, but for one fan point controlled by one way switch complete all as specified and directed.
All as per SI item No. 2.00 here-in-before, but for one exhaust fan point controlled by one way switch complete all as specified and directed.
All as per SI item No. 2.00 here-in-before, but for one 3 pin socket outlet, 5 Amps, single pole on the same board with other switches including continuous 1.5 Sqmm PVC insulated copper conductor earth wire to common wire earth and connecting to earth dolly all as specified and directed.
All as per SI item No. 2.00 here-in-before, but for one 3 pin socket outlet, 15 Amps, independent, with cables 4.00 sq. mm size sheathed stranded 1100 Volt grade complete with 4.00 Sqmm PVC insulated earth wire and connecting to earth dolly all as specified and directed.
All as per SI item No. 2.00 here-in-before, but for one 5 Amp, 3 pin socket outlet on independent board all as specified and directed.
All as per SI item No. 2.00 here-in-before, but for One bell/ buzzer point controlled by one 5 Amps bell push button complete all as specified and directed.
S&F switch piano, flush type single pole, one way 6 Amp complete all as specified and directed.
S&F switch socket combination multi purpose 5 pin 5/6 Amp flush type complete all as specified and directed.
S&F Switch socket combination 2 in 1, 3 pin 6 Amp and 3 pin 16 Amp flush type universal complete all as specified and directed.
S&F Bell push, flush type, 5 Amp, 240 Volt, one way complete all as specified and directed.
S&F in repairs switch piano, flush type single pole, one way 5/6 Amp, 240 Volt complete all as specified and directed.
S&F in repairs Modular switch, one way 6 Amp, 240 Volt 1 module complete all as specified and directed.
S&F in repairs Modular switch, one way 16 Amp, 240 Volt 1 module complete all as specified and directed.
S&F in repairs bell push, flush type, single pole, one way 5 Amp, 240 Volt complete all as specified and directed.
S&F in repairs Modular bell push, one way 6 Amp, 240 Volt 1 module complete all as specified and directed.
S&F in repairs switch socket combination, 5 pin 5/6 Amp flush type complete all as specified and directed.
S&F in repairs socket outlet multipurpose 5 pin, 6 Amp, modular type, 2 module complete all as specified and directed.
S&F in repairs modular white cover plate with frame 1 Module complete all as specified and directed.
S&F in repairs modular white cover plate with frame 2 Module complete all as specified and directed.
S&F in repairs modular white cover plate with frame 3 Module complete all as specified and directed.
S&F in repairs modular white cover plate with frame 4 Module complete all as specified and directed.
S&F in repairs modular white cover plate with frame 6 Module complete all as specified and directed.
S&F in repairs Modular metal flush box 1/2 Module complete all as specified and directed. Note : The contractor will ensure to remove old metal box and fix new, after fixing clear the surface of wall/ceiling with putty and paint to match the existing.
S&F Modular metal flush box 3 Module complete all as specified and directed.
S&F Modular metal flush box 4/5 Module complete all as specified and directed.
S&F Modular metal flush box 6 Module complete all as specified and directed.
S&F in repairs Switch socket combination 2 in 1, 3 pin 6 Amp and 3 pin 16 Amp flush type multipurpose complete all as specified and directed.
S&F in repairs socket outlet multipurpose, 2 module, 2/3 pin combined, 6/16 Amp, modular type, 2 module complete all as specified and directed.
S&F ceiling fan regulator rotary type 120 Watts complete all as specified and directed.
S&F in repairs ceiling fan regulator rotary type 120 Watts complete all as specified and directed.
S&F in repairs ceiling fan regulator modular type 120 Watts complete all as specified and directed.
M&L Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
S&F calling bell, AC, 230 volts, single pole complete all as specified and directed.
S&F distribution board made out of sheet metal enclosure (CRCA sheet powder coated), dust and vermin proof, double door, for enclosing/ fixing MCCB, TPN 4 way, 415 volts grade with 125 Amps vertical type insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urethane (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing complete all as specified and directed.
S&F in replacement MCCB, four pole, 100 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and directed.
S&F in replacement MCCB, four pole, 63 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and directed.
S&F distribution board made out of sheet metal enclosure (CRCA sheet powder coated) dust and vermin proof, double door, for fixing enclosing/ fixing MCB, SPN 8 way, 415 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urethane (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing complete all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB), SP, 5 to 32 Amps current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB), SPN, 32 Amps current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB), SPN, 40 to 63 Amps current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed.
S&F sub-main wiring with 2 runs of 6 sqmm single core PVC insulated, FRLS, unsheathed cable with stranded copper conductor, 1100 Volts grade drawn through and including PVC conduit with all fitting such as Tees, Bends, Elbows, etc., fixed surface on wall/ceiling including 6 Sqmm multistranded PVC insulated, FRLS, copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. NOTE: Two runs of 6.0 sqmm copper cables and one run of 6.0 sq mm copper cable along with white colour PVC conduit/ conduit accessories will be measured as one unit length.
Supply and fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed
S&F in repairs exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.
S&F light frosted glass with chrome finish wall lamp 1 x 4 Watts, warm white, body dark grey colour, aluminium die-cast with IP-65 protection including LED bulb complete all as including taking down existing unserviceable one and removing from site complete all as specified and directed. Make: Jaguar cat No. JNL-CHR-MB160275211A (E27 LED 4W) or equivalent make of Philips/Bajaj/Wipro/Osram/GE/Havells/Goldmedal
S&F smart extruded aluminium LED batten (4ft) with higher efficacy 1x 20W, 220V, AC decorative box type with driver, warm/cool white (as directed by Engr-in-Charge), double sided connection, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, including taking down existing unserviceable one and removing from site complete all as specified and directed. Make: Bajaj Cat No. BCLAB 20W LED P or equivalent make of Philips/Bajaj/Wipro/Goldmedal
S&F in repairs smart LED light in fittings 1 x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in repairs LED light fitting mirror type with high output diffuser 2 feet, 10 watts, 220 V, AC decorative type with warm/cool white (as directed by Engr-in-Charge), driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to galvanised earth lead wire of size 4mm dia by means of GI Bolts, Nuts, check nuts and washers of the earth and thimbles and other end of the earth GI wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia from earth plate to Panel/DBs and water pipe 20mm dia GI medium grade raised up to a level of 50cm above ground level with plug at top, earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 type B-1) cover slab of 50 mm thick using 8.00mm dia CTD bars reinforcement both ways at 140 mm centre to centre with handle, 20 mm dia GI pipe medium grade for watering pipe, wire mesh, funnel and providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/ loose soil, returning, refilling and removing of surplus soil to a distance not exceeding 50 mtr testing complete all as shown in electrical plate No-3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed, including taking down existing unserviceable earthing complete all as specified and directed.
M&L for 4mm dia galvanised iron or steel wire earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed.
S&F in repairs sheet steel metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket complete including one single pole MCB SP 20 Amp, 240 volts complete all as specified and directed.
S&F in repairs LED tube rod (double side connection) ultra bright glass LED tube of Capacity 18W, 230V with high efficiency for installation in existing fittings complete all as specified and directed
S&F in repairs electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc complete all as specified and directed
Taking down unserviceable Refrigerator of any capacity of any make from its location by disconnecting and sealing all electrical connections, transporting the same to Unit Locations for annual maintenance/servicing, dismantling the same for repair/replacement of unserviceable parts and re-assembling after repairs, transporting and refixing the same in its original location, making all electrical connections and testing for effective cooling complete all as specified and directed. NOTE No. 1 The rate quoted shall be deemed to be included the labour charge for replacement of defective major spare parts, but cost of new spare parts will be measured and paid separately under ser item No. 56 to 64 here-in-after "as supply only", NOTE No. 2. The rate quoted shall be deemed to be included cost for replacement of any minor parts which are not catered/ included in Schedule A and required for smooth functioning of refrigerator.
Supply only hermitically sealed compressor for refrigerator of capacity upto 340 ltrs, operating voltage 200V to 240V, 50Hz, with duly filled compressor oil and refrigerant gas R-134A/R-22 in adequate quantity
Supply only starting relay, single phase, 50Hz with connecting leads for refrigerator of any capacity .
Supply only thermostat suitable for refrigerator of any capacity.
Supply only OLP, ISI marked suitable for refrigerator of any capacity
Supply only condensing unit for refrigerator of any capacity.
Supply only evaporator unit suitable for refrigerator of any capacity
Supply only circuit wiring board/PCB suitable for refrigerator of any capacity.
Supply only bi-metal timer, ISI marked suitable for refrigerator of any capacity.
Supply only frost free fan motor suitable for refrigerator of any capacity.
Taking down unserviceable water cooler of any capacity of any make from its location by disconnecting and sealing all electrical connections, transporting the same to Unit Locations for annual maintenance/servicing, dismantling the same for repair/replacement of unserviceable parts and re-assembling after repairs, transporting and refixing the same in its original location, making all electrical connections and testing for effective cooling complete all as specified and directed. NOTE No. 1 The rate quoted shall be deemed to be included the labour charge for replacement of defective major spare parts but cost of new spare parts will be measured and paid separately under ser item No. 66 to 73 here-in-after "as supply only", NOTE No. 2. The rate quoted shall be deemed to be included cost for replacement of any minor parts which are not catered/ included in Schedule A and required for smooth functioning of water cooler.
Supply only hermitically sealed compressor for water cooler, operating voltage 200V to 240V, 50Hz, with duly filled compressor oil and refrigerant gas R-134A/R-22 in adequate quantity
Supply only blower motor 1/32 HP with blower blade assembly for water cooler of any size.
Supply only OLP, ISI marked suitable for water cooler of any capacity.
Supply only starting relay suitable for water cooler of any capacity.
Supply only thermostat suitable for water cooler of any capacity.
Supply only steel tap suitable for water cooler of any capacity.
Supply only PVC connection pipe 450mm long 16mm outer dia with brass nuts, bolts & washers on both side suitable for water cooler of any capacity
Supply only float valve 15mm dia with brass rod, spindle and PVC ball suitable for water cooler of any capacity.
Taking down unserviceable Window type AC of any capacity of any make from its location by disconnecting and sealing all electrical connections, transporting the same to Unit Locations for annual maintenance/servicing, dismantling the same for repair/replacement of unserviceable parts and re-assembling after repairs, transporting and refixing the same in its original location, making all electrical connections and testing for effective cooling complete all as specified and directed. NOTE No. 1 The rate quoted shall be deemed to be included the labour charge for replacement of defective major spare parts, but cost of new spare parts will be measured and paid separately under ser item No. 75 to 84 here-in-after "as supply only", NOTE No. 2. The rate quoted shall be deemed to be included cost for replacement of any minor parts which are not catered/ included in Schedule A and required for smooth functioning of Window type AC.
Supply only starting capacitor of suitable size for operating voltage 240V, 50Hz.
Supply only running capacitor of suitable size for operating voltage 240V, 50HZ.
Supply only blower motor capacitor of suitable size for operating voltage 240 V, 50 HZ
Supply only air filter element for 1.5/2 Ton window type AC of any make.
Supply only thermostat suitable for window type AC of any capacity.
Supply only blower motor 1/6 to 1/8 HP with blower blade assembly for window AC of any size.
Supply only circuit wiring board/PCB suitable for window type AC.
Supply only starting relay with connecting leads for Window type AC of capacity 1.5 Ton.
Supply only condenser unit suitable for window type AC any capacity.
Supply only gun metal bush for blower motor of window type AC.
Taking down unserviceable Split type AC (indoor unit and out door unit)of any capacity of any make from its location by disconnecting and sealing all electrical connections, transporting the same to Unit Locations for annual maintenance/servicing, dismantling the same for repair/replacement of unserviceable parts and re-assembling after repairs, transporting and refixing the same in its original location, making all electrical connections and testing for effective cooling complete all as specified and directed. NOTE No. 1 The rate quoted shall be deemed to be included the labour charge for replacement of defective major spare parts, but cost of new spare parts will be measured and paid separately under ser item No. 86 to 94 here-in-after "as supply only", NOTE No. 2. The rate quoted shall be deemed to be included cost for replacement of any minor parts which are not catered/ included in Schedule A and required for smooth functioning of Split type AC.
Supply only hermitically sealed compressor for Split AC of any capacity, operating voltage 200V to 240V, 50Hz, with duly filled compressor oil and refrigerant gas R-134A/R-22 in adequate quantity
Supply only thermostat suitable for split type AC of any capacity.
Supply only starting relay with connecting leads for split type AC of any capacity.
Supply only starting capacitor of suitable size for split AC of operating voltage 240V, 50Hz.
Supply only running capacitor for suitable size for split AC of operating voltage 240V, 50HZ.
Supply only air filter element for split type AC of any size.
Supply only circuit wiring board/PCB suitable for split type AC.
Supply only blower motor 1/6 to 1/8 HP with blower blade assembly for split AC any size & make.
Supply only condenser unit suitable for split type AC of any size.
Taking out burnt windings from blower fan motor of Window type/Split type AC, cleaning of slots, providing new insulation within slots and winding with new super enamelled copper wire of suitable gauge not less than 300gm/unit including heat varnishing, backing and testing complete all as specified and directed.
Taking down unserviceable window type/split type AC of any capacity of any make from its location by disconnecting and sealing electrical connections, flushing out the compressor oil and refrigerant gas system with CTC and rectifying leakage/block in refrigerant line by cutting, welding/bracing and re-filled with compressor oil and refrigerant gas R-134A/R-22 in adequate quantity, reassembling and refixing the same in its original location and testing for effective cooling complete all as specified and directed.
Taking down unserviceable refrigerator/ water cooler of any capacity of any make from its location by disconnecting and sealing electrical connections, flushing out the compressor oil and refrigerant gas system with CTC and rectifying leakage/block in refrigerant line by cutting, welding/bracing and re-filled with compressor oil and refrigerant gas R-134A/R-22 in adequate quantity, reassembling and refixing the same in its original location and testing for effective cooling complete all as specified and directed.
S&F in repair indoor unit of split type AC 1.5 Ton TR capacity of 3/5 star rating including all suitable necessary fittings complete all as specified and directed by Engineer-in-Charge
S&F in repair indoor unit of split type AC 2.0 Ton TR capacity of 3/5 star rating including all suitable necessary fittings complete all as specified and directed by Engineer-in-Charge
S&F in repair outdoor unit of split type AC 1.5 Ton TR capacity of 3/5 star rating including all suitable necessary fittings complete all as specified and directed by Engineer-in-Charge
S&F in repair outdoor unit of split type AC 2.0 Ton TR capacity of 3/5 star rating including all suitable necessary fittings complete all as specified and directed by Engineer-in-Charge
Taking down unserviceable deep freezer of any capacity of any make from its location by disconnecting and sealing all electrical connections, transporting the same to Unit Locations for annual maintenance/servicing, dismantling the same for repair/replacement of unserviceable parts and re-assembling after repairs, transporting and refixing the same in its original location, making all electrical connections and testing for effective cooling complete all as specified and directed. NOTE No. 1 The rate quoted shall be deemed to be included the labour charge for replacement of defective major spare parts, but cost of new spare parts will be measured and paid separately under ser item No. 103 to 107 here-in-after "as supply only", NOTE No. 2. The rate quoted shall be deemed to be included cost for replacement of any minor parts which are not catered/ included in Schedule A and required for smooth functioning of Deep freezer.
Supply only hermitically sealed compressor for deep freezer of capacity 500 Ltrs, operating voltage 200V to 240V, 50Hz, with duly filled compressor oil and refrigerant gas R-134A/R-22 in adequate quantity
Supply only starting relay with connecting leads for deep freezer of any capacity.
Supply only thermostat suitable for deep freezer of any capacity.
Supply only OLP, ISI marked suitable for deep freezer of any capacity
Supply only condenser unit suitable for deep freezer of any size.
S&F in repair refrigerator of capacity 340Ltrs double door complete all as specified and directed
S&F in repair window type AC 1.5 Ton with five star rating complete all as specified and directed
SUPER COOL (BID ID -3398979)
S L ELECTRICAL WORKS (BID ID -3398836)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .