Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC 1 VILLAGE JYOTISAR DISTT KURUKSHETRA | KURUKSHETRA | HARYANA | 136030 | ₹2.2 Cr | L1 | Accepted-AOC Award |
| 2 | L2₹2.3 Cr+₹6.5 L (2.96%)Rejected-AOC 443 V P O LIWAN 132001 | KARNAL | HARYANA | 132001 | ₹2.3 Cr+₹6.5 L (2.96%) | L2 | Rejected-AOC Reject |
| 3 | L3₹2.3 Cr+₹14.8 L (6.77%)Rejected-AOC NA | ₹2.3 Cr+₹14.8 L (6.77%) | L3 | Rejected-AOC Reject |
| 4 | L4₹2.4 Cr+₹17.2 L (7.89%)Rejected-AOC SCT 3 H NO 2030 ROHTAK SCT 3 H NO 2030 ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹2.4 Cr+₹17.2 L (7.89%) | L4 | Rejected-AOC Reject |
| 5 | L5₹2.5 Cr+₹26.7 L (12.2%)Rejected-AOC FLAT NO 2450 KRISHNA COLONY JIND 126102 | JIND | HARYANA | 126102 | ₹2.5 Cr+₹26.7 L (12.2%) | L5 | Rejected-AOC Reject |
Tender Value
₹2.5 Cr
EMD Value
₹5.0 L
Closing Date
24 Aug 2020, 10:00 amClosed
Executive Engineer, PHED No. 1 Gohana
Executive Engineer, PHED No. 1 Gohana Near MC Park Jind Road Gohana
Special repair for Ist Old WW structures in Gohana Town -Repair of SS tank, Rapid sand filtration plant, repair and raising of Bwall, repair of IC, const. of pucca path and interlocking tiles, repair of Bstn, white washing of whole WW, PM at Old WW.
2020_HRY_139109_1
EIC Memo No. 66880-81-PHED/Urban dt. 04-08-2020
Open Tender
Civil Works
Works
245 days
Gohana Town
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
Executive Engineer, PHED No. 1 Gohana
₹5.0 L
Yes
4 Sept 2020
11 Aug 2020
24 Aug 2020
11 Aug 2020
24 Aug 2020
11 Aug 2020
Amount
Supply & Erection of Horizontal spindle split casing type pumping sets of minimum (4) star rating duties directly coupled to AC squirrel cage induction type motor with accessories complete in all respect with 1440 RPM, 3 phase 50 Hz and accessories complete in all respect with priming arrangement with complete base frame Raw motor 800 LPM 12 Mtr. Head (10.00 HP)
Supply & Erection of Horizontal spindle split casing type pumping sets of minimum (4) star rating duties directly coupled to AC squirrel cage induction type motor with accessories complete in all respect with 1440 RPM, 3 phase 50 Hz and accessories complete in all respect with priming arrangement with complete base frame Clear Water motor 1450 LPM 45 Mtr. Head (30.00 HP)
Supply & Erection of Horizontal spindle split casing type pumping sets of minimum (4) star rating duties directly coupled to AC squirrel cage induction type motor with accessories complete in all respect with 1440 RPM, 3 phase 50 Hz and accessories complete in all respect with priming arrangement with complete base frame Clear Water motor 125.00BHP (At Boosting Station Civil Hospital Gohana)
Supply , erection, testing and commissioning of electric panel board , fabricated from 16 SWG CRCA sheet duly slouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm having following items A) For clear water pump sets for 75 BHP to 125 BHP a) Main switch 125 Amp 2 Nos.(L&T,Siemens,ABB) b)Volt Mtr. 100x100mm range 0 to 500 volt 1 No. (AE/KAPPA?L&T) c)Amp.mtr. 100x100mm range 0 to 100 Amp. 2 Nos. (AE/KAPPA/L&T) d)CT 100/5 2 No. (AE/KAPPA/L&T) e)VSS & ASS 2 No. of approved make f)SPP 2 Nos. approved make (control MCBSP 6am PSP) g)Motor starter , star delta 2 Nos. for75 HP to 125 HP (L&T, Siemens, ABB) h)Capacity of suitable capacity = 2 Nos. i)Indicating Lamp- One Set j)Change over switch125 Amp. = 1 No. k) Moter protection relay- MBR 2.5-5A and all related compoonets as per suitable capacity & as per site requirement (At B/S Civil Hospital Gohana ) for 75 BHP to 125 BHP
Repair of pump set horizontal 75.00 BHP (At ITI Boosting Station Gohana)
Repair of pump set horizontal 125.00 BHP (At Drain No. 8 Boosting Station Gohana)
Supply , erection, testing and commissioning of electric panel board , fabricated from 16 SWG CRCA sheet duly slouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm having following items A) For clear water pump sets for 125 BHP a) Main switch 125 Amp 2 Nos.(L&T,Siemens,ABB) b)Volt Mtr. 100x100mm range 0 to 500 volt 1 No. (AE/KAPPA?L&T) c)Amp.mtr. 100x100mm range 0 to 100 Amp. 2 Nos. (AE/KAPPA/L&T) d)CT 100/5 2 No. (AE/KAPPA/L&T) e)VSS & ASS 2 No. of approved make f)SPP 2 Nos. approved make (control MCBSP 6am PSP) g)Motor starter , star delta 2 Nos. for 125 HP (L&T, Siemens, ABB) h)Capacity of suitable capacity = 2 Nos. i)Indicating Lamp- One Set j)Change over switch125 Amp. = 1 No. k) Moter protection relay- MBR 2.5-5A and all related compoonets as per suitable capacity & as per site requirement (At Drain No. 8 Boosting Station)
Repair of pump set horizontal 75.00 BHP (At Office Campus Boosting Station Gohana)
Repair of pump set horizontal 60.00 BHP (At Office Campus Boosting Station Gohana)
Supply , erection, testing and commissioning of electric panel board , fabricated from 16 SWG CRCA sheet duly slouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm having following items A) For clear water pump sets for 60 BHP to 75 BHP a) Main switch 125 Amp 2 Nos.(L&T,Siemens,ABB) b)Volt Mtr. 100x100mm range 0 to 500 volt 1 No. (AE/KAPPA?L&T) c)Amp.mtr. 100x100mm range 0 to 100 Amp. 2 Nos. (AE/KAPPA/L&T) d)CT 100/5 2 No. (AE/KAPPA/L&T) e)VSS & ASS 2 No. of approved make f)SPP 2 Nos. approved make (control MCBSP 6am PSP) g)Motor starter , star delta 2 Nos. for 60BHP to 75 BHP (L&T, Siemens, ABB) h)Capacity of suitable capacity = 2 Nos. i)Indicating Lamp- One Set j)Change over switch125 Amp. = 1 No. k) Moter protection relay- MBR 2.5-5A and all related compoonets as per suitable capacity & as per site requirement 60 BHP to 75 BHP (at Office Campus Boosting Station)
Prov & fixing concertina wire 1.5 ft. dia mtr including 3 layer straight with MS Angle for support complete in all respect(At Water Works)
Dismentalling of door window which is un repairable / badly rested including loading, unloading, carriage from the site to reserve store
Complete repair of pannel board for clear water and raw water including replacement of all damage / non repairable contractors, relay, timer, volt meter, amp, Meter, wire, MCCB etc with complete wiring i.e. Lighting, motor wiring etc in main pump chamber at 1st water works 2 Nos 100 HP clear water and 3 No. 25 HP Raw water Pump set pannel board.
Providing and fixing approved cholrination system with 3 nos cyclinder, sufficent for 900 Kg gas with all accessories complete in all respect
Prov. & fixing flocculator with motor, gear box, rod etc. with all accessories complete in all respect.
Prov. & fixing blower for back wash in WTP complete in all respect (Approved make)
Design, Supply & Erection of 1 Nos. DG Set of 250 KVA or sutiable capacity on higher side capcity each with chage over switch & synchronizing panel complete in all respect (Approved make)
Supply erection, testing of light fittings including wire in the Pump chamber with material upto 10 points including switch, button, plug, PVC conduct pipe & copper wire etc. as per approved specifications complete in all respect.
Prov. & fixing LED flood light 100 watt including wire, switch board with Switch and socket etc. complete in all respect (Approved makes)
Prov. & fixing MS Sign board and writing with paint complete in all respect (Size 5'x3' with stand)
Painting & writing on walls with paint at all structures complete in all respect
Prov. & Fixing Exhaust fan 12" including wire & complete fitting complete in all respect (Approved make)
Plantation of trees i.e. bottle palm with 6 ft. height = 20 nos, ficu= 40 nos. and fruit tree = 40 nos. & other trees = 20 nos. i.e neem etc including maintaining of trees i.e watering , plugging, cleaning, cutting etc. for 3 months complete in all respect.
Providing and fixing Solar Light system complete with eletric pole complete in all respect (For 2 Nos. W/W, 7 Nos. B/S ) Approved make)
Construction of General Toilet block of size 8'x8' for Operators and variousstaff including provision of 1 no. EWC, 1 No. Urrinal, Washbasin wih all saintary fitting and 1 no. PVC tank 500 ltr. Capacity at 1st Water works complete in all respect.
Providing and fixing of Flow meter in Filter Unit at WTP as per site requirement Ultrasonic / electromagnitc
Providing and fixing of Head loss meter in Filter Unit at WTP
Proviidng and fixing Electrical fitting in Filter house complete in all respect
Providing and fixing of stainless steel railing of SS 304 grade 16 gauge in filter house complete in all respect.
Prov. & fixing Floating Arm of size 12" complete in all respect.
Bidder Name
Amount
Surinder Singh Hooda
Rajesh Kumar
Sh. Ashok Kumar Sindhu
suresh kumar
Krishan Kumar
M/S AAR PEE CONSTRUCTION COMPANY JIND
Krishan Kumar
Surinder Singh Hooda
Sh. Ashok Kumar Sindhu
M/S AAR PEE CONSTRUCTION COMPANY JIND
suresh kumar
suresh kumar
M/S AAR PEE CONSTRUCTION COMPANY JIND
Sh. Ashok Kumar Sindhu
Krishan Kumar
Surinder Singh Hooda
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .