Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹36.5 L+₹17,790 (0.49%)Rejected-AOC | L2 | Rejected-AOC OK | |
| 3 | L3₹39.3 L+₹3.1 L (8.43%)Rejected-AOC 110B CIVIL LINES BAREILLY 243001 UP | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-AOC OK | |
| 4 | L4₹40.6 L+₹4.4 L (12.0%)Rejected-AOC 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L4 | Rejected-AOC OK | |
| 5 | L5₹44.6 L+₹8.3 L (23.0%)Rejected-AOC | L5 | Rejected-AOC OK |
Tender Value
Refer Docs
EMD Value
₹97,800
Closing Date
11 Feb 2021, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR MAINT OF APFC PANEL AND ALLIED WORKS UNDER GE WEST BAREILLY
2021_MES_415308_1
8894/C/E8
Open Tender
Civil Works
Item Rate
330 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORYSCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRM
SCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹97,800
Yes
18 Mar 2021
22 Jan 2021
16 Feb 2021
22 Jan 2021
11 Feb 2021
4 Feb 2021
22 Jan 2021 - 3 Feb 2021
Amount
Repair, maintenance and testing of APFC panel of capacity 450 KVAR including replacment of all unserviceble parts such as contactor, relay, indicator, power capacitor, Electronic Relay(For operating of capacitor), MCCBs and CTs etc, for improving the power factor value. All as specified and directed. Note:- 1-Material such as wire, lugs and ferrule are included in quotated rates. 2- All the material(except wire,lug and ferrule) of APFC panel will be measured paid seperatley under relevant items of schedule 'A' 3- Contactor have to maintain the power factor 0.99 after maintanance of capacitor pannel till the period of defect liability.
(a) Supply only capacitor MPP (H DUTY) type of 50 KVAR 3 phase power capacitor.
(b) Supply only capacitor MPP(H DUTY) type of 40 KVAR 3 phase power capacitor.
(c) Supply only capacitor MPP(H DUTY) type of 25 KVAR 3 phase power capacitor.
(d) Supply only capacitor MPP(H DUTY) type of 10 KVAR 3 phase power capacitor.
(e) Microprocessor based 3 phase current transformer sencing relay 12 stage ( for operating of capacitor bank)
(f) Supply only contactor suitable for MPPH type 50 KVAR 3 phase power capacitor.
(g) Supply only contactor suitable for MPPH type 40 KVAR 3 phase power capacitor.
(h) Supply only contactor suitable for MPPH type 25 KVAR 3 phase power capacitor.
(i) Supply only contactor suitable for MPPH type 10 KVAR 3 phase power capacitor.
(j) Supply only MCCBs 100 Amp, 16 KA, TP for MPPH type 50 KVAR 3 phase power capacitor.
(k) Supply only MCBs 63 Amp, 10 KA, TP for MPPH type 40 KVAR 3 phase power capacitor.
(l) Supply only MCBs 40 Amp, 10 KA, TP for MPPH type 25 KVAR 3 phase power capacitor.
(m) Supply only MCBs 16 Amp, 10 KA, TP for MPPH type 10 KVAR 3 phase power capacitor.
(n) Integrated LED pilot lamp suitable for operating at 220V (AC) Red colour
(o) Integrated LED pilot lamp suitable for operating at 220V (AC) yellow colour
(p) Integrated LED pilot lamp suitable for operating at 220V (AC) Blue colour
(q) Integrated LED pilot lamp suitable for operating at 220V (AC) Green colour
(r) Auto/Manually switch of capacitor bank
(s) Current Transformer suitable for 450 KVAR 415 Volt APFC pannel.
M&L Repairs & overhauling to LT ACBs of any capacity (400 A to 2000 A) of any make by removing out the breaker from the respective panels after taking proper electric shut down & disconnecting the breaker, checking it thoroughly for the defects & tripping system of the ACB and replacing defective spares & rectifing them, lubrication of moving contacts, overhauling of the ACB, replacement of wornout minor spares like springs, washers, levers, nuts & bolts etc reassembling , re-installation ,testing & commissioning of ACB complete all as directed by Engineer-in- charge
Note :(i) Cost of lubricants, cleaning agents, testing tools and minor spares shall be deemed to be including in quoted rates (ii) Cost of spares will be measured & paid seperately under relevant items of schedule 'A'
(a) Supply and fixing of Moving Arcing contacts and adjust the contact pressure of LT ACB of any make any capacity
(b) Supply and fixing of fixed Arcing contact and adjust the contact pressure of LT ACB of any make any capacity
(c) M&L for replacement of main shaft assembly with crank & cam spacer of (400 to 2000 Amps) 3 pole LT ACB of existing make & model and testing for proper operation complete all as directed by Engineer-in-charge
(d) M&L for replacement of Trip coil of LT ACB of any make any capacity all as specified and directed by Engr-in-charge
Repair, maintenance and testing of APFC panel of capacity (50 to 200) KVAR including replacment of all unserviceble parts such as contactor, relay, indicator, power capacitor, Electronic Relay(For operating of capacitor), MCCBs and CTs etc, for improving the power factor value. All as specified and directed. Note:- 1- Material such as wire, lugs and ferrule are included in quotated rates. 2- All the material(except wire,lug and ferrule) of APFC panel will be measured paid seperatley under relevant items of schedule 'A' 3- Contactor have to maintain the power factor 0.99 after maintanance of capacitor pannel till the period of defect Liability.
(a) Supply only capacitor MPP(H DUTY) type of 2 KVAR 3 phase power capacitor.
(b) Supply only capacitor MPP(H DUTY) type of 5 KVAR 3 phase power capacitor.
(c) Supply only capacitor MPP(H DUTY) type of 7.5 KVAR 3 phase power capacitor.
(d) Supply only capacitor MPP(H DUTY) type of 10 KVAR 3 phase power capacitor.
(e) Supply only capacitor MPP(H DUTY) type of 20 KVAR 3 phase power capacitor.
(f) Supply only capacitor MPP(H DUTY) type of 25 KVAR 3 phase power capacitor.
(g) Supply only capacitor MPP(H DUTY) type of 30 KVAR 3 phase power capacitor.
(h) Supply only capacitor MPP(H DUTY) type of 40 KVAR 3 phase power capacitor.
(i) Supply only capacitor MPP(H DUTY) type of 50 KVAR 3 phase power capacitor.
(j) Microprocessor based 3 phase current transformer sencing relay 8 stage ( for operating of capacitor bank)
(k) Supply only contactor suitable for MPPH type 2 KVAR 3 phase power capacitor.
(l) Supply only contactor suitable for MPPH type 5 KVAR 3 phase power capacitor.
(m) Supply only contactor suitable for MPPH type 7.5 KVAR 3 phase power capacitor.
(n) Supply only contactor suitable for MPPH type 10 KVAR 3 phase power capacitor.
(o) Supply only contactor suitable for MPPH type 20 KVAR 3 phase power capacitor.
(p) Supply only contactor suitable for MPPH type 25 KVAR 3 phase power capacitor.
(q) Supply only contactor suitable for MPPH type 30 KVAR 3 phase power capacitor.
(r) Supply only contactor suitable for MPPH type 40 KVAR 3 phase power capacitor.
(s) Supply only contactor suitable for MPPH type 50 KVAR 3 phase power capacitor.
(t) Supply only MCBs 6 Amp TP for MPPH type 2 KVAR 3 phase power capacitor.
(u) Supply only MCBs 10 Amp, 10 KA, TP for MPPH type 5 KVAR 3 phase power capacitor.
(v) Supply only MCBs 16 Amp, 10 KA, TP for MPPH type 7.5 KVAR 3 phase power capacitor.
(w) Supply only MCBs 16 Amp, 10 KA, TP for MPPH type 10 KVAR 3 phase power capacitor.
(x) Supply only MCBs 32 Amp, 10 KA, TP for MPPH type 20 KVAR 3 phase power capacitor.
(y) Supply only MCBs 40 Amp, 10 KA, TP for MPPH type 25 KVAR 3 phase power capacitor.
(z) Supply only MCBs 63 Amp, 10 KA, TP for MPPH type 30 KVAR 3 phase power capacitor.
(i) Supply only MCBs 63 Amp, 10 KA, TP for MPPH type 40 KVAR 3 phase power capacitor.
(ii) Supply only MCCBs 100 Amp, 16 KA, TP for MPPH type 50 KVAR 3 phase power capacitor.
(iii) Integrated LED pilot lamp suitable for operating at 220V (AC) Red colour
(iv) Integrated LED pilot lamp suitable for operating at 220V (AC) yellow colour
(v) Integrated LED pilot lamp suitable for operating at 220V (AC) Blue colour
(vi) Integrated LED pilot lamp suitable for operating at 220V (AC) Green colour
(vii) Auto/Manually switch of capacitor bank
(viii) Current Transformer suitable for 50 to 200 KVAR 415 Volt APFC pannel.
(j) Microprocessor based 3 phase current transformer sencing relay 12 stage ( for operating of capacitor bank)
(j) Microprocessor based 3 phase current transformer sencing relay 16 stage ( for operating of capacitor bank)
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6.0 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32X6 mm GI earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead incased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg) complete all specified and directed.
Supply, installation, commissioning and testing in replacement of APFC panel of capacity 120 KVAR ( 25 KVAR X 2, 20 KVAR X 2, 10 KVAR X 2, 5KVAR X 2,)( FAFA) powder coated factory made outdoor type of suitable size made of CRCA sheet made from min 3.15 mm thick sheet CPRI manufactures with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay complete panel prewired with suitable size of copper cable not less than 2.5 sqmm and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate.Panel comprising with following:-
(a) Incoming MCCB 4 pole 250 Amp 35 KA alongwith Spreader terminals with adjustable thermal setting – 01 Nos
b) Multifunctional 4 in 1 meter like Amp,Voltage, frequency, powerfactor as per capacity of panel = 01 No.
(c) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three
(d) Capacitor MPPH type with suitable size 3 phase power contactors and with individual 3 pole 415 volt MCBs of suitable capacity including indication lamp of each capacitor.
(e) Microprocessor based 3 phase current transformer sencing relay 8 stage = 01 No( for operating of capacitor bank)
(f) Auto/Manually switch of capacitor bank
(g) PCC 1:2:4 for installation of panel
Make of MCCB’s/Relay MCB/power contactor : Legrand / L&T / Schneider /Havells
Make of Capacitor : Shreem / L&T / Schneider/Havells
Supply, installation, commissioning and testing in replacement of APFC panel of capacity 150 KVAR( 25 KVAR X 2, 20 KVAR X 3, 10 KVAR X 3, 5 KVAR X 2,) ( JAT HOUSE) powder coated factory made outdoor type of suitable size made of CRCA sheet made from min 3.15 mm thick sheet CPRI manufactures with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay complete panel prewired with suitable size of copper cable not less than 2.5 sqmm and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate.Panel comprising with following:-
(a) Incoming MCCB 4 pole 350 Amp 35 KA alongwith Spreader terminals with adjustable thermal setting – 01 Nos
b) Multifunctional 4 in 1 meter like Amp,Voltage, frequency, powerfactor as per capacity of panel = 01 No.
(c) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three
(d) Capacitor MPPH type with suitable size 3 phase power contactors and with individual 3 pole 415 volt MCBs of suitable capacity including indication lamp of each capacitor.
(e) Microprocessor based 3 phase current transformer sencing relay 8 stage = 01 No( for operating of capacitor bank)
(f) Auto/Manually switch of capacitor bank
(g) PCC 1:2:4 for installation of panel
Make of MCCB’s/Relay MCB/power contactor : Legrand / L&T / Schneider /Havells
Make of Capacitor : L&T / Schneider/Havells
Supply and laying of XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 120 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per set item No. 9 here-in-before but 150 Sqmm 3½ core.
All as per set item No. 9 here-in-before but 185 Sqmm 3½ core.
All as per set item No. 9 here-in-before but 240 Sqmm 3½ core.
Taking out unserviceable batteries from DC battery bank and S&F with 12 Volts 75 AH batteries complete all as specified and directed.
Supply, installation, commissioning and testing in replacement of APFC panel of capacity 30 KVAR (10 KVAR X 2,5 KVAR X 2) powder coated factory made outdoor type of suitable size made of CRCA sheet made from min 3.15 mm thick sheet CPRI manufactures with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay complete panel prewired with suitable size of copper cable not less than 2.5 sqmm and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate.Panel comprising with following:-
(a) Incoming MCCB 4 pole 100 Amp 16 KA alongwith Spreader terminals with adjustable thermal setting – 01 Nos
b) Multifunctional 4 in 1 meter like Amp,Voltage, frequency, powerfactor as per capacity of panel = 01 No.
(c) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three
(d) Capacitor MPPH type with suitable size 3 phase power contactors and with individual 3 pole 415 volt MCBs of suitable capacity including indication lamp of each capacitor.
(e) Microprocessor based 3 phase current transformer sencing relay 4 stage = 01 No( for operating of capacitor bank)
(f) Auto/Manually switch of capacitor bank
(g) PCC 1:2:4 for installation of panel
Make of MCCB’s/Relay MCB/power contactor : Legrand / L&T / Schneider /Havells
Make of Capacitor : L&T /Schneider/Havells
Supply, installation, commissioning and testing in replacement of APFC panel of capacity 40 KVAR (20 KVAR X1,10 KVAR X 1,5 KVAR X 2) powder coated factory made outdoor type of suitable size made of CRCA sheet made from min 3.15 mm thick sheet CPRI manufactures with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay complete panel prewired with suitable size of copper cable not less than 2.5 sqmm and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate.Panel comprising with following:-
(a) Incoming MCCB 4 pole 100 Amp 16 KA alongwith Spreader terminals with adjustable thermal setting – 01 Nos
b) Multifunctional 4 in 1 meter like Amp,Voltage, frequency, powerfactor as per capacity of panel = 01 No.
(c) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three
(d) Capacitor MPPH type with suitable size 3 phase power contactors and with individual 3 pole 415 volt MCBs of suitable capacity including indication lamp of each capacitor.
(e) Microprocessor based 3 phase current transformer sencing relay 4 stage = 01 No( for operating of capacitor bank)
(f) Auto/Manually switch of capacitor bank
(g) PCC 1:2:4 for installation of panel
Make of MCCB’s/Relay MCB/power contactor : Legrand / L&T / Schneider /Havells
Make of Capacitor : L&T / Schneider/Havells
Supply and fixing of Aluminuim busbar.
Make of Capacitor : L&T / Schneider/Havells
RAZA ENTERPRISES
M/S Rajeev Sharma and Co.
AUTOMATION AND SWITCHGEAR PANELS
Ishtiaq and Sons
Aziz Traders
Mohit Enterprises
M/S Gupta Builders
M/S Gupta and Company
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .