Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹11.6 L+₹72,910 (6.71%)Rejected-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹11.6 L+₹76,171 (7.01%)Rejected-AOC | L3 | Rejected-AOC Not lowest | |
| 4 | Rejected-Technical 0 BEECHPARA DANGAURA MAHENDRAGARH MANENDRAGARH CHIRMIRI BHARATPUR CHHATTISGARH 497442 | KOREA | CHHATTISGARH | 497442 | - | Rejected-Technical Valid cost of tender not uploaded as per Note 6 of NIT |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
27 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jodhpur
GE (AF) Jodhpur
REPAIR REPLACEMENT AND SERVICING OF SPLIT WINDOW TYPE AC AND ALLIED WORKS AT AF STN JODHPUR
2021_MES_485828_1
8491/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE (AF) Jodhpur
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹24,000
Yes
29 Dec 2021
2 Nov 2021
29 Nov 2021
2 Nov 2021
27 Nov 2021
15 Nov 2021
60 days
Amount
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit (Reciprocating compressor) 1.5 Tonne capacity, single phase, 230 volt of including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage, rectification , and Supply & Fixing of new compressor of same capacity and make including gas charging R-22/R-407C and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit (Rotary compressor) 1.5 Tonne capacity, single phase, 230 volt of including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage, rectification , and Supply & Fixing of new compressor of same capacity and make including gas charging R-22/R-407C and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit (Reciprocating compressor) 2 Tonne capacity, single phase, 230 volt of including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage, rectification , and Supply & Fixing of new compressor of same capacity and make including gas charging R-22/R-407C and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit (Rotary compressor) 2 Tonne capacity, single phase, 230 volt of including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage, rectification , and Supply & Fixing of new compressor of same capacity and make including gas charging R-22/R-407C and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for Water Jet servicing of Split type AC of 1.5/2.0 Tonne capacity (complete indoor and outdoor unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor top cover outdoor top cover from existing location, cleaning of cooling coil , condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstall at the same location complete all as specified & directed by the Engineer-in-Charge.
Material & labour for Water Jet servicing of WINDOW TYPE AC's of 1.5/2.0 Tonne capacity (complete unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor & outdoor cover from existing location, cleaning of cooling coil , condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstall at the same location complete all as specified & directed by the Engineer-in-Charge.
Material & labour for Water Jet servicing of CASSET TYPE AC's/DUCTABLE AC's of 2.5/4/5.5 Tonne capacity (complete indoor and outdoor unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor top cover outdoor top cover from existing location, cleaning of cooling coil , condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstall at the same location complete all as specified & directed by the Engineer-in-Charge. Note for Srl Item No.5 to 7 above :- The contractor shall at his own cost arrange water for servicing purpose and also clean the wall & Floor surfaces after servicing and make it neat and tidy to the entire satisfaction of Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 2.5 MFD, 230 volts, 50 HZ suitable for indoor unit complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 4 MFD, 230 volts, 50 Hz.suitable for indoor unit complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 6 MFD, 230 volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 45 MFD, 230 volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 50 MFD 230 volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Starting capacitor of capacity 80-100 MFD, 230 volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
Takigng down existing condensing fan motor from the unit and Material & labour for rewinding of condensing fan motor of capacity 1.5/2.0 Tonne (split type/window type) of any make with super enameled copper winding wire of existing gauge including replacement of the motor bushes and shaft and testing on load for the entire satisfaction of Engineer-in-Charge.
Takigng down existing fan blower motor of cooling unit and Material & labour for rewinding of fan blower motor of cooling unit of capacity1.5/2.0 ton(split type/window type) unit with supper enameled copper winding wire of existing gauge including replacement of the shaft and bushes and testing on load for the entire satisfaction of Engineer-in-Charge.
Supply & fixing in repairs condensing fan motor of capacity 1.5/2.0 Tonne for split type AC single phase, AC 230 volts, 50 Hz of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs condensing fan motor for 1.5 /2.0 Tonne capacity WINDOW type AC single phase, AC 230 volts, 50 Hz of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs condensing fan DC motor for 1.5/2.0 Tonne capacity split type AC (For outdoor unit) of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & Fixing in replacement Blower suitable (for indoor unit) of split type AC of capacity 1.5/2.0 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs fan blades (ISI Marked) of suitable size for outdoor unit of 1.5/2.0 Tonne Split type AC complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs fan blade/blower (ISI Marked) of suitable size for capacity 1.5/2.0 ton of Window type AC complete all as specified & directed by the Engineer-in-Charge.
Material & labour for Repairing of PCB control card suitable for 1.5/2.0 Tonne capacity split /window type AC, single phase and make the PCB control card functional complete to the entire satisfaction of Engineer-in-Charge.
Material & labour for Reparing of PCB control card suitable for 1.5/2.0 Tonne capacity Invertor type split/ window AC, single phase and make the PCB control card functional complete to the entire satisfaction of Engineer-in-Charge.
Supply only in replacement of Remote suitable for 1.5/2.0 Tonne capacity split AC of original make as per existing at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs capillary copper tube (ISI Marked) of split /window type AC capacity 1.5/2.0 Tonne complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs condenser coil for window type AC 1.5/2.0 Tonne capacity of any make including charging of gas R-22/R407C complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs water tray (ISI Marked) for Indoor unit of split AC of any capacity and make AC as approved by Engineer-in-Charge.
Supply & fixing in repairs of relay of split type AC of any make and any capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs thermostat suitable for any make of window type AC 1.5 Tonne capacity complete all as specified & directed by the Engineer-in-Charge. .
Supply & fixing in repairs single pole contactor suitable for split type AC capacity 1.5/2.0 Tonne complete all as specified & directed by the Engineer-in-Charge.
Material & labour for finding out the leakage with the pressure test of the condenser or cooling coil of window type AC's/split type AC's of 1.5/2.0 Tonne and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering with and including charging the gas R-22 and testing the AC to the entire satisfaction of Engineer-in-Charge.
Material & labour for finding out the leakage with the pressure test of the condenser or cooling coil of window type AC's/split type AC's of 1.5/2.0 Tonne and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering with and including charging the gas R-410a/R-407c and testing the AC to the entire satisfaction of Engineer-in-Charge.
Supply, laying and commissioning of cable in replacement PVC sheathed cable with multistranded copper conductor of size 2.5 sqmm 3 core complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs copper tube (ISI Marked) of size ⅝” dia for any capacity of split type AC complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs copper tube (ISI Marked) of size ¼” dia for any capacity of split type AC complete all as specified & directed by the Engineer-in-Charge.
Material & labour in repairs fire resistance, elastomeric Nitrile rubber tubing (NBR) for Pipe insulation thickness 10mm of size ⅝" dia of split type AC's any capacity complete all as specified & directed by the Engineer-in-Charge.
Material & labour in repairs fire resistance, elastomeric Nitrile rubber tubing (NBR) for Pipe insulation thickness 10mm of size¼" dia of split type AC's any capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs flexible drain pipe ( PVC BRAIDED hose pipe) of size 15 mm dia, for split type AC any capacity and any make complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs air filter element suitable for split type AC 1.5/2.0 Ton capacity any make complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs wall mounting bracket stand suitable for 1.5/2.0 tonne capacity outdoor unit of split AC complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs floor mounted bracket AC stand certified special coated super 50cm x 8 cm shelf bracket suitable for 1.5/2.0 ton outdoor unit capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement Voltage Stabilizer of capacity 05 KVA, for automatic operation, single phase naturally air cooled, indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5 % complete all as specified & directed by the Engineer-in-Charge.
Material & labour for sub main wiring with two runs of PVC insulated unsheathed multi stranded copper conductor FRLS cable 4 Sqmm 1100 volt grade and one run of 2.5 Sqmm single core as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm,concealed in wall (including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc.) including 2.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth wire including taking out / down the existing unserviceable sub main wiring with conduit complete all as specified and directed by the Engineer in Charge. Note :- Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Material & labour for sub main wiring with two runs of PVC insulated unsheathed multi stranded copper conductor FRLS cable 2.5 Sqmm 1100 volt grade and one run of 1.5 Sqmm single core as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm,concealed in wall (including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc.) including 1.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth wire including taking out / down the existing unserviceable sub main wiring with conduit complete all as specified and directed by the Engineer in Charge. Note :- Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Supply & fixing in repairs sheet metal enclosure SPN with two pin and earth plug socket with & including 20Amps MCB 'C' curve single pole 240 Volt AC complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs MCB SP 25 Amp, ‘C’ curve type, 10 KA complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repair MCB SPN 25 Amp ‘C’ curve type, 230 volts, 10 KA complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs MCB SP 20 Amp ‘C’ curve type, 230 volts, 10 KA complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement 3 pin plug top cap 15 Amp AC 240 Volts 50 Hz complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement 3 pin socket 20 Amp AC 240 Volts 50 Hz for AC metal clad box complete all as specified & directed by the Engineer-in-Charge.
Dismantling of split AC/window AC any capacity with proper pumpdown from the site and diposit to MES work shop for major repair works complete all as specified & directed by the Engineer-in-Charge.
Fixing & commisioning only of split/window type AC capacity 1.5/2.0 Tonne (AC dismantled from item no.49 above shall be reused) including testing after installation complete all as specified & directed by the Engineer-in-Charge. Note :- Copper tubing if required shall be measured & paid seprately.
Supply & fixing in replacement Display card of Indoor unit of Split AC capacity 1.5 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement Display card of Indoor unit of Split AC capacity 2.0 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement Complete Indoor unit with remote of Split AC capacity 1.5 Tonne any make complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement Complete Indoor unit with remote of Split AC capacity 2 Tonne any make complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs L & key valve (ISI Marked) of size 5/8" for condenser unit split type AC 1.5/2.0 Tonne , proper leak test check shall be carried after replacement of valve complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs L & key valve (ISI Marked) of size 1/4" for condenser unit split type AC 1.5/2.0 Ton , proper leak test check shall be carried after replacement of valve complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs of flair nut size 5/8" and 1/2"dia for split type AC of any capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs of flair nut size 3/8" and 1/4" dia for split type AC of any capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs of dead nut size 1/4 '' dia for any capacity of split type AC complete all as specified & directed by the Engineer-in-Charge.
Material & labour for filling of Refrigerant R-22 complete all as specified & directed by the Engineer-in-Charge.
Material & labour for filling of Refrigerant R-410/407 complete all as specified & directed by the Engineer-in-Charge.
Material & labour for MCB DB SPN 8 way IP-54 double door concealed in wall IP 54 protection with MCB SPN ‘C’ Curve type 40 amps - 01 No and MCB SP ‘C’ Curve type 6 to 32 amps - 06 Nos including necessary connection lugging with copper lugs pin/Ring type including dismantling & taking down the old unservicable DB with accessories and also making good disturbed surfaces of walls to match with existing specificationsof walls complete all as specified & directed by the Engineer-in-Charge.
Material & labour for MCB DB SPN 4 way IP-54 double door concealed in wall IP 54 protection with MCB SPN ‘C’ Curve type 40 amps - 01 No and MCB SP ‘C’ Curve type 6 to 32 amps - 02 Nos including necessary connection lugging with copper lugs pin/Ring type including dismantling & taking down the old unservicable DB with accessories and also making good disturbed surfaces of walls to match with existing specificationsof walls complete all as specified & directed by the Engineer-in-Charge.
Supply & Fixing in repairs AC motor suitable for Indoor unit blower of split type AC 1.5/2.0 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & Fixing in repairs DC motor suitable for Indoor unit blower of split type AC 1.5/2.0 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Material and labour for writing SM number on split/window AC on both indoor and outdoor units with red synthetic enamel paint in appropriate manner as directed complete all as specified & directed by the Engineer-in-Charge.
Supply & Fixing in repairs room temperature sensor of split/window AC complete all as specified & directed by the Engineer-in-Charge.
Material & labour for sealing the bore holes of walls with expandable polyurethane foam complete all as specified & directed by the Engineer-in-Charge. Note :- Only existing Holes in walls to be sealed.
Shri Electrical Enterprises
J AND T Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .