Loading…
Loading…
Tender ID
Tender Value
₹1.6 L
EMD Value
₹3,891
Closing Date
11 Feb 2026, 11:00 amClosed
AssistantEngineer
LID EW VAZHOOR SUB DIVISION
Annual Plan-Vazhoor BP Project No-S0103/26-Provision of Drinking Water facility for the ADA office-General Electrical Work
2026_LSGD_833075_1
AE/LSGD/TDR/06-2025-26
Open Tender
Electrical Works
Item Rate
180 days
Chamampathal
Please refer Tender documents.
7 documents required · 7 mandatory
₹296
₹3,891
3 Feb 2026
3 Feb 2026
12 Feb 2026
3 Feb 2026
11 Feb 2026
3 Feb 2026
Provision of Drinking water facility for the ADA office ( List of materials used for the work approved by the DLTCE under LSGD Kottayam is attached as separate document)
OD168570/2025-2026:Supply, conveyance, installation, testing and commissioning of DECCAN Make, Model:-20D8/8,2HP 8 Stage Three phase Openwell Submersible Pump, Head Range: 25/64(Mtrs), Discharge Range: 120/40LPM Delivery Size: of 40mm, etc.or Equivalent make.
OD168589/2025-2026:Supply and providing L&T make 2 HP MU-G6S SMART CONTROLLER DOL (CS91206CSDO) with complete operation (Remote ON/OFF, parameter setting, monitoring and troubleshooting through SMS or SMART COMM App or IVRS)with digital control panel and protection against overload, auto on or auto off timer, dry run, high and low voltage, single phasing, unbalance.
OD168573/2025-2026:Supply and fitting 32mm KARTAR Sluice valve with flanges.
OD168571/2025-2026:Supply and fitting 32 mm Non Return valve using required bolt and nut and flange etc
OD168577/2025-2026:Supply and fixing 32mm hook type SS hose holder
OD168579/2025-2026:Supply and providing 32mm Socket
OD168580/2025-2026:Nut& Bolt with washesr 2x5/8
OD168576/2025-2026:Supply and fitting 32 mm GI Bend on pumping main
OD168581/2025-2026:Supply and providing 40mm PVC Coupling.
OD168575/2025-2026:Supply and Providing 40mm PVC pipe Cutting , joining etc with accessories etc
OD168569/2025-2026: Supply and provide NYLON ROPE MAXIMA LG 14MM for hanging Pump set
OD168574/2025-2026:Supply and provide 32mm (H) Clamp set for hanging pumpset
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
OD168572/2025-2026:Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
OD168588/2025-2026:Supply and providing 12x3mm brass bolt and nut with washers on the existing MS box/earth bus etc.as required including drilling necessary holes as required.
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD168583/2025-2026:Supply and Installation of Thermo Circuit Breaker Box Glass Door Enclosure 8 way IP65 HENSEL make for surge protection device
OD168584/2025-2026:Supply and installation of Type 1+2,Surge Protection Device having Configuration 3P+N,4module,Maximum Discharge Current-Imax upto 100KA,,in the existing enclosure and giving connections as required (L&T Make AUSP123PN100 or equivalent)
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
90.14.24.16:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.1 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors.
OD168587/2025-2026:Supply and Installation of 25x6 cu. strip Earth bench used for connecting copper conductor
OD168585/2025-2026:Supply and Installation of dust and Vermin proof, wall mounting,Sintex meter box of size 650*350*210mm suitable to fix single phase energy meter and to fix in the box one set of 63A,415V HRC Bakelite fuse fitting with HRC fuse link,63A 2 way neutral link etc.GSMB6535
OD168582/2025-2026:Supply and providing anchor bolt hook type on wall/parapet for binding KSEB Service connection capable as required
OD168586/2025-2026:Charges for preparing drawing of the complete Electrical Installation after completion of the present work and preparing completion report with KSEB service connection application form and submitting to the consumer for availing 3 phase service connection/Load regularaization
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.17 MB
BOQ_1400749.xls
BOQ • 0.32 MB
sbdadaele.pdf
Tender Documents • 1.63 MB
ADANIT.pdf
Tender Documents • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .