Loading…
Loading…
Tender Value
₹15 L
EMD Value
₹5,000
Closing Date
21 Apr 2026, 6:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
Chief Officer
Construction & Repairing Work of All Old and New Civil Work Maintenance With All Material and Labour For KHEDA Nagarpalika
294492
202-27 KNP/TDR/7
Open
Civil Works
Kheda
3 documents required · 3 mandatory
₹1,000
Chief Officer Kheda Nagarpalika
₹5,000
6 Apr 2026
6 Apr 2026
6 Apr 2026
21 Apr 2026
6 Apr 2026
Name of work: Construction & Repairing Work of All Old and New Civil Work
Maintenance with All Material and Labour For Mahemdabad
SCHEME : Self Fund
MAHEMDAVAD NAGARPALIKA
Name of work: Annual Rate for Construction & Repairing Work (Year 2024-25) at Bareja
SCHEME : Government Grant/ Self Fund
No. Item Description Unit Rate
Excavation for foundation up to 1.5 m depth including sorting
1 out and stacking of useful materials and disposing off the cu.m 115.92
excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Excavation for foundation up to 1.5 m depth including sorting
2 out and stacking of useful materials and disposing off the cu.m 148.19
excavated stuff up to 50 Meter lead.(B) Dense or Hard soil
Excavation for foundation for depth from 1.5 m to 3.0 m
including sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(A)
Loose or soft soil
Excavation for foundation for depth from 1.5 m to 3.0 m
including sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(B)
Dense or Hard soil
Excavation for foundation for depth from 3.0 m to 5.0 m including
sorting out and stacking of useful materials and disposing
off the excavated stuff upto 50 Meter lead.(A) Loose or soft
Excavation for foundation for depth from 3.0 m to 5.0 m
including sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(B)
Dense or Hard soil
Filling available excavated earth (excluding rock) in trenches.
plinth, sides of foundations etc. in layers not exceeding 20 cm.
in depth consolidating each disposited layer by ramming and
Filling in plinth with sand under floors including watering
ramming, consolidating and dressing complete
Filling in foundation and plinth with murrum or selected soil in
9 layers of 20cm. thickness including watering, ramming and cu.m 279.23
consolidating etc. complete.
Filling in foundation and plinth with brick Bats Chhara in layers of
20cm. thickness including watering, remming and consolidating etc.
10 complete. cu.m 594.61
Excavation for foundation upto 1.5 m depth including sorting
out and stacking of useful materials and disposing off the
excavated stuff upto 50 Meter lead.(A)
Loose or soft soil ( EXECUTED WITH MANUAL LABOUR)
Excavation for foundation upto 1.5 m depth including sorting
out and stacking of useful materials and disposing off the
excavated stuff upto 50 Meter lead.(B)
Dense or Hard soil ( EXECUTED WITH MANUAL LABOUR)
Excavation for foundation for depth from 1.5 m to 3.0 m
including sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(A)
Loose or soft soil( EXECUTED WITH MANUAL LABOUR)
Excavation for foundation for depth from 1.5 m to 3.0 m
including sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(B)
Dense or Hard soil( EXECUTED WITH MANUAL LABOUR)
Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse
sand : 6- hand broken stone aggregates 40 mmnominal size) and
curing complete excluding cost of formwork in (A) Foundation and
Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse
sand : 8- hand broken stone aggregates 40 mm nominal size) and
curing complete excluding cost of formwork in (A) Foundation and
Providing and laying cement concrete 1:3:6 (1- Cement : 3- Coarse
sand : 6- crushed stone aggregates 20 mm nominal size) and
17 curing complete including cost of formwork in (A) Wall Caps / cu.m
Providing TMT Bar FE 500D reinforcement for R.C.C. work
18 including bending, binding and placing in position complete upto kg 66.59
floor two level
Extra for additional lift of concrete for all R.C.C. work above floor
two level excluding cost of reinforcment
Extra for additional lift of reinforcing steel for all R.C.C. work
above floor two level.
Providing upto floor two level precast cement concrete jali or grill
1:2:4 mix (1- Cement : 2- coarse sand : 4- graded stone
aggregate 6mm nominal size) reinforced with 1.6 mm dia.
Mild steel wire including roughening,cleaning, fixing and
finishing in cement mortar 1:3 and curing complete. (B) 40mm
Providing upto floor two level precast cement concrete jali or grill
1:2:4 mix (1- Cement : 2- coarse sand : 4- graded stone
aggregate 6mm nominal size) reinforced with 1.6 mm dia.
Mild steel wire including roughening,cleaning, fixing and
finishing in cement mortar 1:3 and curing complete. (C) 25mm
Providing and laying damp proof course 25mm thick cement
23 concrete 1:2:4 (1-Cement : 2 coarse sand : 4 stone aggregate Sqm 302.34
10 mm nominal size) and curing complete
Providing and laying controlled cement concrete M.150 for curing
complete excluding cost of formwork and reinforcement for
reinforced concrete work in (A) Foundations, footings, Base of
columns and Mass concrete.
Providing and laying controlled cement concrete M.150 for curing
complete excluding cost of formwork and reinforcement for
reinforced concrete work in (B) Walls, from top of foundation level
upto floor two level
Providing and laying controlled cement concrete M.150 for curing
complete excluding cost of formwork and reinforcement for
26 reinforced concrete work in (C) Slabs, landing, shelves, Balconies, cu.m
Lintels, Beams, Girders and Cantilever upto floor two level
Providing and laying controlled cement concrete M.150 for curing
complete excluding cost of formwork and reinforcement for
reinforced concrete work in (D) Columns, Pillars posts and struts
upto floor two level.
Providing and laying controlled cement concrete M.150 for curing
complete excluding cost of formwork and reinforcement for
reinforced concrete work in (E) Staircases excluding landing upto
floor two level
Providing and laying controlled cement concrete M.150 for curing
complete excluding cost of formwork and reinforcement for
reinforced concrete work in (K) Vertical and Horizontial its upto
floor two level.
Providing and laying controlled cement concrete M.200 and curing
complete excluding the cost of formwork and reinforcement for
reinforced concrete work in (A) Foundations, footings, Base of
columns and Mass concrete
Providing and laying controlled cement concrete M.200 and curing
complete excluding the cost of formwork and reinforcement for
reinforced concrete work in (B) Walls, from top of foundation level
upto floor two level
Providing and laying controlled cement concrete M.200 and curing
complete excluding the cost of formwork and reinforcement for
reinforced concrete work in (C) Slabs,landing,shelves,Balconies
Lintels, Beams, Girders and Cantilever upto floor two level.
Providing and laying controlled cement concrete M.200 and curing
complete excluding the cost of formwork and reinforcement for
reinforced concrete work in (D) Columns, Pillars posts and struts
upto floor two level.
Providing and laying controlled cement concrete M.200 and curing
complete excluding the cost of formwork and reinforcement for
34 reinforced concrete work in (E) Staircases excluding landing upto cu.m
floor two level
Providing and laying controlled cement concrete M.200 and curing
complete excluding the cost of formwork and reinforcement for
reinforced concrete work in (K) Vertical and Horizontial its upto
floor two level.
Providing and laying controlled cement concrete M.250 and curing
complete excluding the cost of formwork and reinforcement for
36 reinforced concrete work in (A) Foundations, footings, Base of cu.m
columns and Mass
Providing and laying controlled cement concrete M.250 and curing
complete excluding the cost of formwork and reinforcement for
reinforced concrete work in (B) Walls, from top of foundation level
upto floor two level
Providing and laying controlled cement concrete M.250 and curing
complete excluding the cost of formwork and reinforcement for
reinforced concrete work in (C) Slabs,landing,shelves,Balconies,
Lintels, Beams, Girders and Cantilever upto floor two level.
Providing and laying controlled cement concrete M.250 and curing
complete excluding the cost of formwork and reinforcement for
reinforced concrete work in (D) Columns, Pillars posts and struts,
upto floor two level.
Providing and applying anticarrasive treatment with polymer
base materials to the steel rainfarcement including descaling
the dust and applying the preventive coating of approved make (for
the R.C.C. structures near coastal area only) etc complete.
Providing and laying in position Ready Mixed M-200 grade
concrete for reinforced cement conctere work , using cement
content as per approved Design Mix manufactured in fully
automatic batching plant and transported to site of work in transit
mixer for a lead up to 10 kms having continuous agitated
mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of R.M.C.
from transit mixer to site of laying, excluding the cost of centering
shuttering finishing and reinforcement including cost of
admixtures in recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete, improve workability
without impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash (Min cement level as per
latest IS 456 shall be maintained)
Providing and laying in position Ready Mixed M-250 grade
concrete for reinforced cement conctere work , using cement
content as per approved Design Mix manufactured in fully
automatic batching plant and transported to site of work in transit
mixer for a lead up to 10 kms having continuous agitated
mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of R.M.C.
from transit mixer to site of laying, excluding the cost of centering
shuttering finishing and reinforcement including cost of
admixtures in recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete, improve workability
without impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash (Min cement level as per
latest IS 456 shall be maintained) (Cement level 450 kg )
Brick work using common burnt clay building bricks having
crushing strength not less than 35 kg./Sq.Cm. in foundation and
plinth in Cement Mortar 1:6 (1- Cement
: 6 -fine sand)(B) Conventional
Brick work using common burnt clay building bricks having
44 crushing strength not less than 35 kg./Sq.Cm. in foundation and cu.m
plinth in Cement Mortar 1:6 (1- Cement
: 6 -fine sand)(C) Fly Ash Bricks
Extra for brick work in superstructure above plinth level upto floor
two level (B) Conventional
Extra for brick work in superstructure above plinth level upto floor
46 two level(C) Fly Ash Bricks cu.m 265.65
(ii) Half brick masonry in common brunt clay building bricks
having crushing strength not less than 35 Kg/Sq.Cm. in
Cement mortar 1:5 (1- Cement : 5 -coarse sand ) in foundation and
plinth (B) Conventional
(ii) Half brick masonry in common brunt clay building bricks
having crushing strength not less than 35 Kg/Sq.Cm. in
Cement mortar 1:5 (1- Cement : 5 -coarse sand ) in foundation and
plinth (C)Fly Ash Bricks
Extra for brick work in superstructure above floor two level Item
No. 5 (B) Coventional
Half brick masonry in common brunt clay building bricks having
crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar
50 1:3 ( 1-Cement : 3-coarse sand ) with 2 Nos of 6mm Mild steel Sqm 656.64
round bars after every three course embedded in Cement Mortar
in foundation and plinth (B) Conventional
Half brick masonry in common brunt clay building bricks having
crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar
51 1:3 ( 1-Cement : 3-coarse sand ) with 2 Nos of 6mm Mild steel Sqm 735.90
round bars after every three course embedded in Cement Mortar
in foundation and plinth (C)Fly Ash Bricks
Providing formwork of ordinary timber planking so as to give a
rough finish including centering shuttering strutting and
propping etc. Height of propping and centering below
supporting floor to ceiling not exceeding 4 M. and removal
of the same for in situ reinforced concrete and plain concrete
work in. (A) Foundations Footings Bases of Columns etc. and
Providing formwork of ordinary timber planking so as to give a
rough finish including centering shuttering strutting and
propping etc. Height of propping and centering below
supporting floor to ceiling not exceeding 4 M. and removal
of the same for in situ reinforced concrete and plain concrete
work in. (B) Flat surfaces such as soffits of supspened floors
slabs Landings and the like. (1) Floors etc. upto 200 mm in
Providing formwork of ordinary timber planking so as to give a
rough finish including centering shuttering strutting and
propping etc. Height of propping and centering below
supporting floor to ceiling not exceeding 4 M. and removal
of the same for in situ reinforced concrete and plain concrete
work in. (B) Flat surfaces such as soffits of suspended floor roof
slabs Landings and the like. (2) Floors etc. above 200mm in
Providing formwork of ordinary timber planking so as to give a
rough finish including centering shuttering strutting and
55 propping etc. height of propping and centering below Sqm 229.95
supporting floor to ceiling not exceeding 4 M. and removal
of the same for in situ reinforced concrete and plain concrete
work in. (C) Vertical surface such as walls (any thickness)
partitions and the like including attached buttresses & string
course & the like.
Providing formwork of ordinary timber planking so as to give a
rough finish including centering shuttering strutting and
propping etc. height of propping and centering below
supporting floor to ceiling not exceeding 4 M. and removal
of the same for in situ reinforced concrete and plain concrete
work in. (G) Columns PillarsPosts and struts. (1) Square
Polygonal in plan.
Providing formwork of ordinary timber planking so as to give a
rough finish including centering shuttering strutting and
propping etc. height of propping and centering below
supporting floor to ceiling not exceeding 4 M. and removal
of the same for in situ reinforced concrete and plain concrete
work in. (G) Columns PillarsPosts and struts. (2)Circular or curved
Providing formwork of ordinary timber planking so as to give a
rough finish including centering shuttering strutting and
propping etc. height of propping and centering below
supporting floor to ceiling not exceeding 4 M. and removal
of the same for in situ reinforced concrete and plain concrete
work in. (H) (1) Sides and soffits of Beams Beam Haunchings
cantilevers Girders Bressumers and Lintels not exceeding 1 M. in
Providing formwork of ordinary timber planking so as to give a
rough finish including centering shuttering strutting and
propping etc. height of propping and centering below
supporting floor to ceiling not exceeding 4 M. and removal
of the same for in situ reinforced concrete and plain concrete
work in. (H) (2) Sides and soffits of Beams Beam Haunchings
canti- levers Girders Bressumers and Lintels exceeding 1M.in
Providing formwork of ordinary timber planking so as to give a
rough finish including centering shuttering strutting and
propping etc. height of propping and centering below
supporting floor to ceiling not exceeding 4 M. and removal
of the same for in situ reinforced concrete and plain concrete work
in. (I) Edges of slabs and Breaks in floors and walls.
Providing formwork of ordinary timber planking so as to give a
rough finish including centering shuttering strutting and
propping etc. height of propping and centering below
supporting floor to ceiling not exceeding 4 M. and removal
of the same for in situ reinforced concrete and plain concrete
work in. (K) Small surfaceassuch as cantiever brackets and ends
of steps caps and basses to pilasters and Columns and the
Providing formwork of ordinary timber planking so as to give a
rough finish including centering shuttering strutting and
propping etc. height of propping and centering below
supporting floor to ceiling not exceeding 4 M. and removal
of the same for in situ reinforced concrete and plain concrete
work in. (L) Chullah Hoods, weather shades Chhajjas Corbels
including edges.
Providing formwork of ordinary timber planking so as to give a
rough finish including centering shuttering strutting and
propping etc. height of propping and centering below
63 supporting floor to ceiling not exceeding 4 M. and removal Sqm 242.55
of the same for in situ reinforced concrete and plain concrete
work in. (M) Staircase with sloping or stepped soffits including
risers and stringers excluding landing.
Providing formwork of ordinary timber planking so as to give a
rough finish including centering shuttering strutting and
propping etc. height of propping and centering below
supporting floor to ceiling not exceeding 4 M. and removal
of the same for in situ reinforced concrete and plain concrete
work in. (Q) Vertical fins and vertical sun breakers.
Providing wood work in frames of Doors, windows cleare story
65 windows and othersimilar works wrought, framede and fixed in 602.04
position. (A) Indian Teak Wood
Providing wood work in Trusses, Purling, Rafter, Post,Post
66 Plates, wall plates and the like wrought framed, hoisted and Cu.Dm.
fixed in position
Providing wood work in frames of false- ceiling, partitions etc
sawn and put up in position. (A) Indian Teak Wood
Providing and fixing 35 mm thick shutters for Doors, windows
68 and clear story windows including anodised alluminium butt hinges Cu.Dm.
with necessary screws.(A) Indian Teak Wood (1) Fully Panelled
Providing and fixing 35 mm thick shutters for Doors, windows
69 and clear story windows including anodised alluminium butt hinges Sqm
with necessary screws. (A) Indian Teak Wood (ii) Fully Glazed.
Providing and fixing 35 mm thick shutters for Doors, windows
and clear story windows including anodised alluminium butt hinges
with necessary screws. (A) Indian Teak Wood(iii) Partly panelled and
Providing and fixing 35 mm thick shutters for Doors, windows
and clearstory windows including blackenamelled M.S. butt
hinges with necessary screws. (A) Indian teak wood. (i) Fully
Providing and fixing 35 mm thick shutters for Doors, windows
72 and clearstory windows including blackenamelled M.S. butt Sqm
hinges with necessary screws. (A) Indian teak wood. (ii) Fully Glazed.
Providing and fixing 35 mm thick shutters for Doors, windows
and clearstory windows including blackenamelled M.S. butt
hinges with necessary screws. (A) Indian teak wood. (iii) Partly
panelled and partly glazed.
Providing and fixing 25 mm thick shutters for cupboards etc.
74 including anodised alluminium butt hinges with necessary Sqm
screws. (A) Indian teak wood. (i) Fully Panelled.
Providing and fixing 25 mm thick shutters for cupboards etc.
75 including anodised alluminium butt hinges with necessary Sqm
screws. (A) Indian teak wood. (ii) Fully Glazed.
Providing and fixing 25 mm thick shutters for cupboards etc.
including anodised alluminium butt hinges with necessary
screws. (A) Indian teak wood. (iii) Partly panelled and partly
Providing and fixing 25 mm thick shutters for cupboards etc.
including black enamelled M.S. butt hinges with necessary
screws. (A) Indian teak wood. (i) Fully
Providing and fixing 25 mm thick shutters for cupboards etc.
78 including black enamelled M.S. butt hinges with necessary screws. Sqm
(A) Indian teak wood. (ii) Fully Glazed.
Providing and fixing 25 mm thick shutters for cupboards etc.
including black enamelled M.S. butt hinges with necessary
screws. (A) Indian teak wood. (iii) Partly panelled and partly
Provoding and fixing flush door shutters, solid core
construction with frame of first class hardwood with cross board
and face veneer or plywood face panels, including anodised
alluminium butt hinges with necessary screws. (B) Non-
decorative type and block board core anodised alluminium butt
hinges in flush door shutters (2) 35 mm thick.
Providing and fixing M.S. grills of required pattern to wooden
frames of windows etc. with M.S. flats at required spacings
and frame alround, square or round bars with round headed bolts
and nuts or by screws (A) Plain Grill.
Providing and fixing M.S. grills of required pattern to wooden
frames of windows etc. with M.S. flats at required spacings
and frame alround, square or round bars with round headed bolts
and nuts or by screws. (B) ORNAMENTAL GRILL
Providing and fixing 35 mm thick shutters for Doors, windows
and clerestory windows including Indian teak wood frames
83 cm x 7 cm. size including anodized alluminium fixtures and Sqm
fastenings including primer coat of approved quality and two coats
of oil painting etc, complete. (i) Fully Glazed.
Providing and fixing 35 mm thick shutters for Doors, windows
and clerestory windows including Indian teak wood frames
84 cm x 7 cm. size including anodized alluminium fixtures and Sqm
fastenings including primer coat of approved quality and two coats
of oil painting etc, complete. (ii) Fully Panelled.
Steel work, riveted in built up sections framed work including
cutting, hoisting, fixing in position and applying a priming coat of red
lead paint. (A) In beams and joists, channels angles Tees, flats, with
connecting plates or angle cleats as in main and cross beams.
Hip and jack rafters, purlins conneted to common rafters and the
Steel work, riveted in built up sections framed work including
cutting, hoisting, fixing in position and applying a priming coat of
red lead paint. (D) In trussses and trussed purlins, upto 25 M. span
and 15 M ovarall height.
Providing and fixing rolling shutters of approved make made of
80 mm wide M.S. laths inter-locked together through their entire
length and jointed together at the ends by end locks mounted
87 on specially designed pipe shaft with bracket plates, guide Sqm
channels and arrangements for inside and outside locking with
push- pull operation complete but excluding the cost of hood cover
and spring. (A) Shutters having width below 3.5.M.
Providing and fixing M.S. Fan clamps type 1 to 16mm dia M.S. bar
bent to shape with hooked ends to R.C.C. slabs curing, laying
including painting the exposed portion of loops, all as per standard
design complete.
Providing and fixing window having extruded aluminum Colour
anodized section frame main outer size 95mm x 24mm x 1.17mm @
wt.of 0.738 Kg/mt , horizontal Three track member size 92mm x
31.75mm x 1.30mm,@ Wt.1.07 Kg/mt , vertical member of
size 92mm x 31.75mm x 1.50mm @ Wt. 1.06 Kg/mt with
89 sliding shutters of horizontal member size 40 mmx18mm Sqm
x1.29mm @ wt.of 0.456 Kg/mt, vertical member of size 40mm x
18mm x 1.29 mm @ wt.of 0.456Kg/mt/ with 5 mm thick transparent
bronze colour tinted float glass with powder coated aluminum
fittings and fixtures and transparent silicon sealant glass fixing to
frame as per details etc
Providing and fixing window having extruded aluminum Colour
anodized section frame main outer size 63.50 x 38.10 x
mm,@ Wt 1.094 Kg / Rmt, horizontal two track member size
61.85 mm x 31.75 mm x 1.20mm @ wt.of 0.695 Kg/mt, vertical
member of size 61.85 mm x 31.75mm x 1.30 mm @ wt.of
Kg/mt with sliding shutters of horizontal member size 40mm x
18mm x 1.29mm @ wt.of 0.456Kg/mt, vertical member of size
Kg/mt with 5 mm thick transparent bronze colour tinted float glass
with powder coated aluminum fittings and fixtures and transparent
silicon sealant glass fixing to frame as per details etc complete for
Providing and fixing standared extruded of alluminium section of
size 63.50 x 38.10 x 1.95 mm @ Wt 1.094Kg / Rmt with colour
anodized alluminium frame with 5 mm thick transparent bronze
colour tinted float glass with colour anodized alluminium frame for
ventilation with 5 mm thick frosted glass as details etc
complete for.window
Providing and fixing standared extruded of alluminium section of
size 63mm x 38.10mm x 1.2mm @ Wt. 0.643 Kg/mt with colour
anodized alluminium frame for ventilation with 5 mm thick
frosted glass as details etc complete for Ventilation
Providing and laying precast terrazo tiles 20mm thick with
marble chips of sizes. upto 6mm in skirting and risers of steps not
exceedings 30 cms. in height on 10mm thick cement plaster 1:3 (1-
cement : 3-coarse sand ) jointed with neat cement slurry
including rubbing and polishing complete with tiles of. (A) Light
shades using white cement
Providing laying precast terrazo tiles 20mm thick with marble
chips of sizes. upto 6mm in skirting and risers of steps not
exceedings 30 cms. in hieght on 10mm thick cement plaster 1:3
(1-cement : 3-coarse sand ) jointed with neat cement slurry
including rubbing and polishing complete with tiles of. (B) Medium
Shades using approx. 50% white Cement and 50% ordinary cement
Providing and laying white glazed tiles 6mm thick in flooring
treads of steps and landing laid on a bed of 12mm thick cement
mortar 1:3 (1-cement : 3-coarse sand ) finishing with flush pointing
in white cement.
Providing and laying Ceramic tiles 6mm thick in flooring treads of
steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-
cement : 3-coarse sand ) finishing with flush pointing in white
Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24''
97 in flooring treads of steps and landing laid on a bed of 12mm thick Sqm
cement mortar 1:3 (1-cement : 3- coarse sand ) finishing with
flush pointing in white cement.
Providing and laying Vitrified tiles 8 to 10 mm thick , 36'' x 36'' in
flooring treads of steps and landing laid on a bed of 12mm thick
cement mortar 1:3 (1-cement : 3- coarse sand ) finishing with
flush pointing in white cement.
Providing and layingCeramic tiles 6mm thick in skrting risers of
99 steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3- Sqm 971.78
coarse sand) and jointed with white cement slurry
Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24'' in
100 skrting risers of steps and dedo on 10mm thick cement plaster 1:3 Sqm
(1-cement : 3-coarse sand) and jointed with white cement slurry
Providing and laying polished Kota stone slab flooring over 20mm
(Average) thick base of cement mortar 1:6 (1 cement : 6-coarse sand)
101 or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed Sqm 544.03
with grey cement slurry mixed with pigment to match the shade
of slab including rubbing and polishing etc. complete. (A) 25mm thick
Providing and laying polished Kota stone slab flooring over 20mm
(Average) thick base of cement mortar 1:6 (1 cement : 6-coarse
sand) or L.M. 1.1.5 laid over and jointed with grey cement slurry
including rubbing and polishing etc. complete. (B) 30 mm thick
Providing and laying polished kota stone slab 25mm thick in
risers of steps,skirting Dedo and pillars laid on 10mm thick
103 cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with Sqm
gray cement slury mixed with pigment to match the shade of
slab including rubbing and polishing etc. complete.
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average)
base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface
or fixing on existing flooring by adhesive material including
dismentaling of existing flooring and jointed with color cement
slurry including finised with flush pointing & cleaning the surface
etc. complete for DARK shade
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average)
base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface
or fixing on existing flooring by adhesive material including
dismentaling of existing flooring and jointed with color cement
slurry including finised with flush pointing & cleaning the surface
etc. complete for antiskit
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average)
base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface
or fixing on existing flooring by adhesive material including
dismentaling of existing flooring and jointed with color cement
slurry including finised with flush pointing & cleaning the surface
etc. complete for light shade
Providing and fixing pre-cast concrete kerb stone of gray cement
based concrete block 30cm length,30cm height and 15cm thick of
107 M200 grade concret as per approved design and including excavation Rmt 381.15
for fixing in proper line and level,filling the joint with C:M 1:3
(1cement:3fine sand) etc complete.
Providing and fixing pre-cast Rubber Dye / steel Dye inter locking
concrete block 60mm thick with grade of concrete M300
pnumatic compressed / vibrated mechanically and as per
approved design Confirming to IS 15658 : 2006 including 35 mm Sand
layer for levelling and filling the joint with sand in proper line and
level as per guidlines of IRC : SP 63-2018 etc. Complete.
Providing and laying broken chine mosaic flooring for
terrace using 12 mm to 20 mm broken pieces of glazed tiles to
be laid over cement mortar 1:3 to plain or slope and to be
109 tempered to bring mortar creme out upto surface using Sqm 739.89
white cement including rounding off junctions and extending
them upto 15 cm along the wall,clearing with water and oxalic acid
etc. as directed.
Providing corrugated G.I. sheet of class-3 roofing fixed with
glavanished iron J or L Hooks, Bolts and nuts 8mm diameter with
bitumen and G.I. limpet washer or G.I. limpet washer. filled with
white lead complete excluding the cost of purlins, Rafters and
Trusses.(1) 0.80 mm thick
Providing ridges or hips 600 mm overall in plain G.I. sheet class-3
fixed with G.I.J. or L Hooks and nuts 8mm dia G.I. Limpet and
bitumen washer complete. (1)
mm thick sheet.
Providing valleys 900mm overall in plain 1.6mm thick
G.I. sheet fixed with G.I. J or L Hooks, Bolts and nuts glavanised
iron J or L Hooks Bolts and nuts 8mm dia G.I. Limpet and bitumen
washers complete.
Providing and fixing 150mm wide 450mm over all semicircular
plain G.I.sheet class-3 gutter with Iron brackets 40mm x 3mm
size Bolts, Nuts, washers etc. including making necessary
connection with rain water pipes. (i) 0.80 mm thick Sheet.
Providing and fixing on wall face C.I. Rain water pipe including
filling the joints with spun yarn soaked in neat cement slurry and
cement mortar 1:2 (1- Cement : 2-fine
sand) (A) 75 mm dia.
Providing and fixing eco-friendly light weight calcium silicate false
ceiling tiles having Tegular edge & 15 mm Thick Densified edges
on the Tile Periphery for Extra Strength The Light weight calcium
silicate ceiling tiles shall have , light reflection 85% non-combustible
B.S. 476 part IV, 100% humidity resistance and also having
thermal conductivity0.043° w/m KC.for the best thermal Insulation
. The Light weight calcium Silicate tile shall be of approved
texture Fine fissured/ Spintone/Cosmos having NRC value of
0.5 & Globe having NRC value of 0.75 NRC or equivalent of size
X 595 mm to be laid on true horizontal level suspended inter
locking metal grid of hot dipped galvanized steel sections
(galvanizing @120 grams per sqm including both side)
consisting of main ‘T’ runner suitably spaced at joints to get
required length and size of 24X38mm made from 0.30 mm thick
(minimum) sheet, 1200mm centre to centre, and cross ‘T’ of size
24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm
along spaced between main ‘T’ at 600mm centre to centre to form
agrid of 1200X600mm and secondary cross ’T’ of length 600mm
and size 24x28mm made of 0.30 mm thick (Minimum) sheet to be
interlocked at middle of the 1200X600mm panel to form grid of
size 600X600mm resting on periphery walls/partitions on a
perimeter wall angle pre-coated steel of size (24X24X3000mm made
of 0.40mm thick (minimum) sheet with the help of rawl etc.
Pro. And fixing single layer water proof gypsum board 12.5 mm
thick sections using water proof board of size 1220 mm x
mm x 8.0 mm suspended by GI suspender channel of size
25 mm x 3 mm with intermediate channel og size 18 mm x
mm x 0.8 mm at 1220 mm center to center ceiling section of size
116 40 mm x 35 mm x 0.55 mm at 457 mm c/c and perimeter channel A Sqm 600.94
of size 20 mm x 27 mm x 30 mm x 0.5 mm at edges & drops
incl.paper tap sand sofit cleat, anchor fastener, scoch bolt
connecting cleat,joining compound top coat on ceiling incl.making
necy.opening for light fitting,diffuser etc. comp. as per detail
drawing as directed
Providing 15mm thick cement plaster in single coat on Rough
(Similar)side of single or half brick walls for interior plastering
upto floor two level and finished even and smooth in (iii) Cement
mortar 1:3 (1-cement:3-sand)
Providing 20mm thick cement plaster in single coat on single or
half brick walls for interior plastering upto floor two level and
finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-
20mm thick sand faced cement plaster on walls upto height
metres above ground level consisting of 12mm thick backing
119 coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of Sqm 332.33
C.M. 1:1 (1-cement : 1-
sand) etc. complete.
Pointing on brickwork with cement mortar 1:3 (1- cement : 3-
coarse sand) (A) Flush pointing
Pointing on coursed stone masonry with cement mortar 1:3 (1-
cement : 3-coarse sand) (A) Flush pointing
Pointing on Uncoursed stone masonry with cement mortar 1:3
(1-cement : 3-coarse sand) (A) Flush pointing
Providing 20 mm thick double coat mala cement plaster on interior
brick / concrete work for plastering comprising of base coat
of 12 mm thick cement plaster in cement mortar (1 Cement :
coarse sand) in rough finishing and 8 mm thick top coat of cement
mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel including
scaffolding curing etc. complete.
White washing with lime on wall surface (two coats) to give an
124 even shade including thoroughly booming the surface to remove Sqm 11.97
all dirt, dust; mortar drops and other foreign matter.
Colour washing with lime on wall surface (two coats ) over and
including a primary coat of white washing to give an even shade
after through brooming the surface to remove all dirt, dust, mortar
drops and other foreigh matter.
Distempering with dry distemper of approved brand and manufacture
(two coats) and of required shade on wall surfaces of given an
126 even shade, over and including a priming coat of whiting after Sqm 46.94
thoroughly brooming the surface free from mortar dropping and
other foreign matter.
Distempering with dry distemper of approved brand and manufacture
(One coats) and of required shade on wall surfaces of given an
127 even shade, after thoroughly brushing the surface clean of all Sqm 14.81
grease, dirt, loose pieces of scales including preparing the surface
even and sand papered smooth.
Distempeing (Two coats) with oil bound distemper of approved
brand and manufacture and of required shade on wall surfaces to
give an even shade, over and including a priming coat with
128 distemper primer of approved brand and manufacture after Sqm 71.19
thoroughly brushing the surface free from mortar dropping and
other foreign matter and also including preparing the surface
even and sand papered smooth.
Distempeing (One coats) with oil bound washable distemper of
approved brand and of required shade on wall surfaces to give an
even shade, after thorouhly brushing the surface clean of all grease
dirt, loose pieces of scales and also including distempering with oil
bound washable distemper of preparing the surface even and
Finishing wall with water proofing cement paint of on wall
surfaces (Two coats) to give an approved brand and manufacture
and of required shape even shade after thoroughly brushing the
surface to remove all dirt and remains of loose powered materials.
Wall painting (two coats) with plastic emulsion paint of approved
brand and manufacture on undecorated wall surface to give an
131 even shade including throughly brushing the surface free from Sqm 78.12
mortar droppings and other foreign matter and sand papered
Applying priming coat over new steel and other metel surface
after and including preparing the surface by throughly cleaning,
oil,grease, dirt and other foreign matter and scoured with
brushes fine steel wood, scrapers and sand paper with ready
mixed priming paint
brushing red lead.
Painting two coats (excluding priming coat) on new steel and other
metal surface with enamel paint, brushing, interior to give an
133 even shade including cleaning the surface an even shade Sqm 68.94
including cleanicn the surface of all dirt, dust and other foreign
Painting one coats (excluding priming coat) on previously painted
steel and other metal surface with enamel paint, brushing to give an
even shade including cleaning the surface of all dirt, dust and other
foreign matter.
Painting two coats (excluding priming coat) on new steel and other
metal surface with synthetic enamel paint, brushing to give an
even shade including cleaning the surface of all dirt, dust and other
foreign matter.
Painting one coats (excluding priming coat) on previously printed
steel and other metal surface with synthetic enamel paint,
brushing to give an even shade including cleaning the surface of
all dirt, dust and other foreign matter.
Painting two coats (excluding priming coat) on new wood
and wood based surface with enamel paint, interior to give an
even shade including cleaning the surface of all dirt, dust and
other foreign matter sand papering and stopping.
Painting one coats (excluding priming coat) on previously painted
wood and wood based surface with enamel paint, to give an
even shade including cleaning the of all dirt, dust and other foreign
Polishing with french polish on new wood and wood based
139 surface to give an even surface including cleaning, the surface of all Sqm 131.84
dirt, dust and sand papering smooth and including a coat of wood
Polishing with french polish on previously polished wood and wood
based surface to give an even surface including cleaning, the
surface of all dirt, dust and sand papered smooth and including a
coat of wood filler.
Painting lines, deashes, arrows, letters etc on roads, Air fields and
like in two coats with road marking paint, brushing including
cleaning the surface of all dirt, dust and other foreign matter. (i)
Over 10cm in width
Finishing wall with weather proof exterior emulsion paint on
wall surface (two coats) to give an required shape even shade
after thoroughly brushing the surface to remove all dirt, and
remains of loose powdered materials.etc complete
Applying two coats of putty & two coats of primer of approved
brand and manufacture on new wall surface to give an even shade
including thoroughly brushing the surface free from mortar
dropping and other foreign matter and sand papered smooth.
Demolition and disposal of unserviceable materials with all lead and
lift.(i) Lime concrete.
Demolition including stacking of serviceable materilas and disposal
of unserviceable materials with all lead and lift. (i) R.C.C. work
Demolition of Brick work and stone masonry including stacking
146 of serviceable materilas and disposal of unserviceable cu.m 352.80
materials with all lead and lift.(ii) In Cement Mortar.
Demolition of terrace including stacking of serviceable materilas
147 and disposal of unserviceable materials with all lead and lift.(i) Brick Sqm 61.59
Dismentaling tiled of stone floors laid in mortar including
148 stacking of serviceable materilas and disposal of unserviceable Sqm 46.31
materials with all lead and lift.
Dismentaling of wooden floors including stacking of
149 serviceable materilas and disposal of unserviceable materials Sqm 69.30
with all lead and lift.
Dismentaling of sheet roofing including ridges, Hips, Valleys,
150 Gutters etc. stacking of serviceable materilas and disposal of Sqm 46.31
unserviceable materials with all lead and lift.(i) G.I.sheet roofing.
Dismentaling of sheet roofing including ridges, Hips, Valleys,
151 Gutters etc. stacking of serviceable materilas and disposal of Sqm 51.51
unserviceable materials with all lead and lift.(ii) A.C. sheet roofing.
Dismentling wood work, wrought framed and fixed in frames
trusses including stacking the materials with all lead and lift.
Dismentling expanded metal or I.R.C Fabric with necessary
153 battens and beadings including frame work, and stacking the Sqm 53.87
serviceable materials with all lead and lift.
Dismentling steel work including distempering and stacking the
materials with all lead and lift.
Dismentling doors, windows, ventilators etc. (wood or steel)
shutters including chowkhats architraves, holdfasts and
other attachment etc. complete and stacking them within all lead
and lift.(i) Not exceeding 3 Sq.M. in area.
Dismentling doors, windows, ventilators etc. (wood or steel)
shutters including chowkhats architraves, holdfasts and
other attachment etc. complete and stacking them within all
lead and lift.(ii) Exceeding 3 Sq.M. in area.
Dismentling barbed wire in fencing including making rolls and also
including dismentling fencing posts including all earth work
concrete in base and making good the disturbed ground
stacking useful materials as directed and disposing as directed
and disposing of the unserviceable materials with all lead and
Dismentling C.I. pipes G.S.W.pipes abd A.C. rain water pipes with
158 fittings and clamps including stacking the materials with all lead Rmt 72.30
and lift ( for any dia, of pipe)
Dismantling santtary fittings like wash basin . W.C. pan Indian
159 and European type, flushing tank etc. including stacking the Each 390.60
materials with all lead and lift.
Scraping oil paint from steel and other metal surface and making the
surface even (with Hand Scraping.)
Removing and scraping of old deteriorated plaster of any thickness
fromm wall / R.C.C member including stacking of serviceable
material and disposal of unserviceable from site of work with all
Providing and fixing PUF Insulated continueous sandwich panels for
roofs of total thickness not less than 30 mm made out from
continue line method.Panel shall have 0.5 mm thick pre coated
GI sheet on both side of Polyurethane foam with external face
being corrugated in shape for GI and PU foam both material.The
crest height of the panel shall be of 35mm minimum wiht
250mm c/c pitch. The Precoated sheet shall be of minimum
240 mpa steel grade confirming to IS 14246:1995 and
shall have zinc coating of 120 gsm as per IS:277 , 5-7 microns
162 epoxy primer on both side of the sheet and polyester top coat 15- Sqm
18 micron.The PPGI Sheet shall have protective guard film of
minimum 25 microns to avoid scratches wihile trasportation.The
roof panels are laid over a frame work of trusses, columns and
purlins fixed using 90mm self drilling bolt with rubber washer
including all types of flashings. PU Foam must be self-extinguishing,
fire retardant type having minimum density of 40 Kg/Cu.mt.( +, -
2 Kgs) including 0.25mm craft paper edging,self tapping screws
of required length and nos.etc complete as per structural design
and direction of Engineer-in-charge.
Providing and fixing PUF Insulated continueous sandwich panels for
walls of total thickness not less than 50 mm and width 1.0 m made
out from continue line method on automatic plant.Panel shall
have 0.5 mm thick pre coated GI sheet on both side of
Polyurethane Foam confirming to IS 12436:1988.The Precoated
sheet shall be of minimum 240 mpa steel grade confirming to IS
14246:1995 and shall have zinc coating of minimum 120 gsm as per
IS:277:1992 , 5-7 microns epoxy primer on both side of the
sheet and polyester top coat 15-18 micron.The PPGI Sheet shall
have plastic protective guard film of minimum 25 microns to
avoid scratches during trasportation.The panels shall be vertically
joined together by tongue and groove joints. The PU Foam shall be
self-extinguishing, fire retardant type having minimum
density of 40 Kg/Cu.mt.( +, - 2 Kgs) including 0.25 mm thick
craft paper edging on both edges. The panels shall be fixed to
the steel frame structure with minimum 5mm thick self tapping
GI screws of required length and nos. with minimum spacing of
Providing and fixing PUF Insulated continueous sandwich panels for
walls of total thickness not less than 40 mm and width 1.0 m made
out from continue line method on automatic plant.Panel shall
have 0.5 mm thick pre coated GI sheet on both side of
Polyurethane Foam confirming to IS 12436:1988.The Precoated
sheet shall be of minimum 240 mpa steel grade confirming to IS
14246:1995 and shall have zinc coating of minimum 120 gsm as per
IS:277:1992 , 5-7 microns epoxy primer on both side of the
sheet and polyester top coat 15-18 micron.The PPGI Sheet shall
have plastic protective guard film of minimum 25 microns to
avoid scratches during trasportation.The panels shall be vertically
joined together by tongue and groove joints. The PU Foam shall be
self-extinguishing, fire retardant type having minimum
density of 40 Kg/Cu.mt.( +, - 2 Kgs) including 0.25 mm thick
craft paper edging on both edges. The panels shall be fixed to
the steel frame structure with minimum 5mm thick self tapping
GI screws of required length and nos. with minimum spacing of
Structural steel work ( Confirming to IS 4923-1997) riveted,
bolted or welded in builtup for all type sections, in framed work,
including cutting, hoisting, fixing in position and applying a
priming coat of approved steel primer all complete as per the
structural designs and directions of Engineer in charge.Column (
Providing and fixing of Bottom and top U track for closing of
end joints for cut PUF panels of size of 52mm x 30mm with 5mm
lipping on Both edges. The U track shall be made out of 0.5 mm
thick pre coated GI sheet.The Precoated sheet shall be of
minimum 240 mpa steel grade confirming to IS 14246:1995 and
shall have zinc coating of minimum 120 gsm as per IS:277:1992
166 5-7 microns epoxy primer on both side of the sheet and Rmt 577.18
polyester top coat 15-18 micron. The PPGI Sheet shall have
plastic protective guard film of minimum 25 microns to avoid
scratches during transportation. The U track shall be fixed with
suitable POP rivet with wall roof panels and plinth with
Expandable fastners with minimum spacing of 450 mm c/c. The
Utrack shall be fixed
Providing and fixing M.S. fan clamps of shape and size as specified in
167 existing R.C.C. slab including cutting chase Each 173.25
and making good.
Cutting out cracks of roof terrace to V- section , cleaning out, wetting
, grouting with cement and sand slurry 1:3 (1-cement 3-sand )
Cutting out cracks roof terrace to V-Section cleaning out and filling
169 solidly with a hot mixture of bitumen and clean dry sand (1:1 by Rmt 74.34
Providing and fixing 1.20 Metre high fencing with 2.0 Metre long
M.S. Angle posts 40mm x 40 mm x6 mm and oil painting 3 coats
fixed at 2.5 Mt,C/c. with five Horizontan lines and two
170 diagonals of galvanised steel barbed wire weighting 9.38 Kg. per 100 Rmt 385.40
Metre, strained and fixed to posts with G.I,staples including fixing
the postsin ground with 0.5 M x 0.5.M x 0.5 M. block in
C.C1:5:10 etc complete.
Constructing a sink (chowkedi) with C.C. 1:2:4, 12cm. thick over
B.B. masonry in C.M,(1:6) in front and dwarf wall 1.0 Mt.high and
23 cm.thick cement plaster to masonry / in C.M.1:3) and cement
concrete flooring in 1:2:4: mi x 5 cm. dia. drain pipe etc.complete.
Constructing a cooking platform 60 cm. width and 70 cm high resting
on B.B.Masonry walls 23 cm.thick in C.M.(1:6) with (i) Fixing
172 or precast R.C.C.1:2:4) 8 cm. thick slab with marble chips set in Rmt
C.M. (1:6) (6mm thick terrazo) with plastering on exposed faces
walls in C.M. (1:4) etc complete.
Applying general insecticide pest control treatment to floors,
cupboards etc including labour materials etc. complete. Using
Imidacloprid 30.5 SCas Per IS 6313 part - II( (0.075% concentration
by mass) is recommended 10.5ml chemical diluted with 5 liters of
water application 0.5 litre chemical /Sqm of surface is
recommended as per I.S.
Carring out plinth treatment to post construction / existing
structure by spraying chemical solution for termite control
treatment including labour and material consistment with I.S.I
specification. Using Chlordene and Chiorpurfiles 20 EC. As Per
6131_paret-II Consentration Weight one percent is recommended i.e
one litre 20 EC chemical emulsion with 19 liter give 1 %
concrentration inclusive of one litre chemical emulsion appication at
the rate of 5 Litre chemical / Sqm of surface is
recommended as per I.S
Providing and laying, Spreading and compacting graded stone
aggregate to wet mix macadam specification including premixing the
material with water at OMC in mechanical mix plant carriage of mixed
material by tipper to site,laying in uniform layers with motor grader in
sub-base/base course on well prepared surface and compacting with
vibratory roller to achieve the desired density.
Supply & fixing factory finished cold formed Light guage steel frame
sections confirming to SP:6 (5) 1980 at site or work including
riveted, bolted or welded in builtup for all type of sections ,in
framed work, cutting, hoisting, fixing in position and applying
primer coat of approved steel primer etc. complete as per
structural designs & directions of Engineer-in-charge.
Providing and fixing to wall ceiling and floor 6.0 Kg. F/Cm2
working pressure poluthene pipes of the following outside
177 Dia. Low densidy, complete with special falnge compression Rmt 64.89
type fittings, wall clipsetc. including making good the wall
ceiling and floor.(A)20mm
Providing and fixing to wall ceiling and floor 6.0 Kg. F/Cm2
working pressure poluthene pipes of the following outside
178 Dia. Low densidy, complete with special falnge compression Rmt 80.64
type fittings, wall clipsetc. including making good the wall
ceiling and floor.(B)25mm
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2
working pressure poluthene pipes of the following outside
179 Dia. Low densidy, complete with special falnge compression Rmt 96.56
type fittings, wall clipsetc. including making good the wall
ceiling and floor.(C) 32mm
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2
working pressure poluthene pipes of the following outside
180 Dia. Low densidy, complete with special falnge compression Rmt 124.43
type fittings, wall clipsetc. including making good the wall
ceiling and floor.(D) 40mm
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2
181 working pressure poluthene pipes of the following outside Rmt 163.80
Dia. Low densidy, complete with special falnge compression
type fittings, wall clipsetc. including making good the wall
ceiling and floor.(E) 50mm
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2
working pressure polythene pipes of the following outside
182 Dia. Low densidy, complete with special falnge compression Rmt 274.68
type fittings, wall clipsetc. including making good the wall
ceiling and floor.(F) 75mm
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2
working pressure poluthene pipes of the following outside
183 Dia. Low densidy, complete with special falnge compression Rmt
type fittings, wall clipsetc. including making good the wall ceiling
and floor.(G) 110mm
Providing and fixing cast iron spigot and socket soil, waste and
ventilating pipes of the following nominal size.(B) 75mm dia.
Providing and fixing cast iron spigot and socket soil, waste and
ventilating pipes of the following nominal size.(C) 100mm dia.
186 Providing and fixing in position cowel went to pipes.(B) 75mm dia. Each 732.09
Providing and fixing in position cowel went to pipes.(C) 100mm
Providing and fixing cast iron (Spun) Nahni trap of the following
nominal diameter of self cleaning design with C.I. screaed down
or higned grating including cost of cutting and making good the
walls and floor 100mm inlet and 50mm outlet.(C) 100mm dia.
Providing and fixing water closet squatting Pan (Indian type W.C.
Pan) size 580mm (Earthwork, bed concrete, foot reste and trap
to be measured and paid for separately) (A) Vitreous China.(I)
Long pattern = White colour
Providing and fixing wsh down water closet (European type,
W.C. Pan) with integral P or S trap including jointing the trap
190 with soil pipe in Cement Mortar 1:1 (1- Cement : 1-fine sand) (Seal Each
and cover to be measured and paid for separately)(A) vitreous
China Pattern :(i) in white colour
Providing and fixing in Cement Mortar 1:3 (1-Cement : 3 coarse
191 sand)a, pair of white vitreous China 250mm x 130mm x 30mm Each 113.54
footrest to long pattern squatting pan water closet.
Providing and fixing 12.5 Litres high level C..I. flushing cistern
with A pair of C.I. or Mild steel brackets, womplete with
fittings such as syplionic arrangement, 15mm nominal size brass
ball valve with polythene float, lever G.I. China (60 cm. ) and pull
union and couplings for connections with inlet, outlet and
overflow pipes etc. including cutting holes in walls and making
good the same (overflow pipe to be measured and paid fo
Providing and fixing in position with clamps etc. 32mm nominal
internal diameter galvanised steel tube flush pipe for high level
flushing cistern including connecting the flush pipe with cistern
and closet and making good the walls and floors.
Providing and fixing G.I. inlet connection for flush pipe with W.C.
Providing and fixing plastic seat and cover for wash down water
195 closer with C.P. brass hinges and rubber buffers. (B) Black plastic Each 288.45
seal and cover.
Providing and fixing washbasin with single hole for pillar tap with C.I.
196 or M.S. brackets painted white including sutting holes and Each
making good the same but excluding fittings.(A) Vitreous
China:(ii) Flat Back washbasin 550 mm x v 400mm size. (i) In white
Providing and fixing Kitchen sink with C.I. or M.S. brackets,
painted white including cutting holes in walls and making good
the same but excluding fittings. (C) Vitreous China Sink.(i) 600mm x
450mm x 150mm size
Providing and fixing C.P. brass waste for washbasin or sink. (A)
Providing and fixing C.P. brass waste for washbasin or sink. (B)
Providing and fixing M.I. fisher union for washbasin or sink. (A)
Providing and fixing M.I. fisher union for washbasin or sink. (B)
Providing and fixing 100mm sand cast iron grating for gully, floor
Providing and fixing C.P. brass shower rose with 15mm or 20mm
inlet.(A) 100mm dia. Each
Providing and fixing 600mm x 450mm bevelled edge mirrror of
204 superior glass mounted on 6mm thick A.C. sheet or plywood sheet Each 825.48
and fixing to wooden pluge with C.P. brass screws and washers.
Providing and fixing C.P. brass towel rail comlete with C.P. brass
205 brackets fixed to wooden plugs with C.P. brass scews.(B) 600mm x Each 597.22
Providing and fixing 600mm x 120mm glass shelf with C.P. brass
206 bracket and guard rail complete mixed to wooden plug with C.P. Each 510.30
207 Providing and fixing toilet paper holder.(A) C.P. Brass Each 414.53
Providing and fixing screw down bib taps of following size.(A)
Brass screw down bib tap polished bright. (i) 15mm dia.
Providing and fixing screw down bib taps of following size.(A)
Brass screw down bib tap polished bright. (ii) 20mm dia.
Providing and fixing screw down bib taps of following size.(B)
Brass chromium plated screws down Bib Tap. (i) 15mm dia.
Providing and fixing screw down bib taps of following size.(B)
Brass chromium plated screws down Bib Tap. (ii) 20mm dia.
Providing and fixing screw down bib taps of following size.(C)
Gun metal screw down bib tap. (i) 15mm dia.
Providing and fixing screw down bib taps of following size.(C)
Gun metal screw down bib tap. (ii) 20mm dia.
Providing and fixing pillar tap, capstan head, screw down
high pressure with screws, shanks and back nuts. (i) 15mm dia.
Providing and fixing pillar tap, capstan head, screw down
high pressure with screws, shanks and back nuts. (ii) 20mm dia.
216 Providing and fixing brass screw down stop tap.(A) 15mm dia. Each 203.79
217 Providing and fixing brass screw down stop tap.(B) 20mm dia. Each 221.59
218 Providing and fixing brass screw down stop tap.(C) 25mm dia. Each 218.63
Providing and fixing Gun metal check or non-return fullway
wheel valve.(A) 15mm dia.
Providing and fixing Gun metal check or non-return fullway
wheel valve.(B) 20mm dia.
Providing and fixing Gun metal check or non-return fullway
wheel valve.(C) 25mm dia.
222 Providing and fixing Gun metal check or non-return fullway Each 311.61
wheel valve.(D) 32mm dia.
Providing and fixing Gun metal check or non-return fullway
wheel valve.(E) 40mm dia.
Providing and fixing chromium plated brass half trun flush cock of
224 approved quality including fixing in pipe line etc. complete.(i) 20mm Each 252.26
Providing and fixing chromium plated brass half trun flush cock of
225 approved quality including fixing in pipe line etc. complete.(ii) 25mm Each 261.16
Providing and fixing chromium plated brass half trun flush cock of
226 approved quality including fixing in pipe line etc. complete.(iii) 32mm Each 273.03
Providing and fixing Urinal or approved quality including conecting
the Urinal with waste pipe , tap etc. complete.(A) White
earthenware flat back or corner type size 430mm x 260mm x
Providing and fixing Urinal of approved quality including connection
with trap and with integral longitudinal flush pipe.(A) Squating plate
pattern white earthenware
229 Providing and fixing Rubber plug for sink or wash basin. Each 16.98
Providing and fixing chromium plated, bottle trap with necessary
couplings of approved quality for wash basin.
Providing and fixing ball cock of approved. quality as directed.(A)
Copper Metal (i) 25mm dia.
Providing and fixing ball cock of approved. quality as directed.(A)
Copper Metal (ii) 50mm dia.
Providing and fixing ball cock of approved. quality as directed.(B)
Abonite (i) 25mm dia.
Providing and fixing ball cock of approved. quality as directed.(B)
Abonite (ii) 50mm dia.
Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. size having
weight not less than 35Kg.
Providing and fixing G.I. Rain water spout of 50mm dia. and 30cm.
Providing and fixing concealed center point to wall ceiling &
floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation
237 (NSF) seal for potable water of following dia. nominal bore tube Rmt 165.21
fittings and clamps including making good the wall, ceiling and
floor etc. complete.[A] 15 mm.
Providing and fixing concealed center point to wall ceiling &
floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation
238 (NSF) seal for potable water of following dia. nominal bore tube Rmt 202.97
fittings and clamps including making good the wall, ceiling and
floor etc. complete. [B] 20 mm.
Providing and fixing concealed center point to wall ceiling &
floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation
239 (NSF) seal for potable water of following dia. nominal bore tube Rmt 247.25
fittings and clamps including making good the wall, ceiling and
floor etc. complete. [C] 25 mm.
Providing and fixing concealed center point to wall ceiling &
floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation
240 (NSF) seal for potable water of following dia. nominal bore tube Rmt 330.36
fittings and clamps including making good the wall, ceiling and
floor etc. complete. [D] 32mm.
Providing and fixing concealed center point to wall ceiling &
floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation
241 (NSF) seal for potable water of following dia. nominal bore tube Rmt 437.66
fittings and clamps including making good the wall, ceiling and
floor etc. complete. [E] 40mm.
Providing and fixing concealed center point to wall ceiling &
floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation
242 (NSF) seal for potable water of following dia. nominal bore tube Rmt 647.30
fittings and clamps including making good the wall, ceiling and
floor etc. complete. [F] 50mm.
Providing laying and jointing in true line and level 15mm dia. U.P.V.C.
Pipe ( SCH- 40) for cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the wall with the help of
243 clamp at every two metre C/C or shall be concealed as directed Rmt 71.93
including necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost of all
Providing laying and jointing in true line and level 25mm dia. U.P.V.C.
Pipe ( SCH- 40) for cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the wall with the help of
244 clamp at every two metre C/C or shall be concealed as directed Rmt 90.93
including necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost of all
Providing laying and jointing in true line and level 32mm dia. U.P.V.C.
Pipe ( SCH- 40) for cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the wall with the help of
245 clamp at every two metre C/C or shall be concealed as directed Rmt 117.97
including necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost of all
Providing laying and jointing in true line and level 40mm dia. U.P.V.C.
Pipe ( SCH- 40) for cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the wall with the help of
246 clamp at every two metre C/C or shall be concealed as directed Rmt 146.65
including necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost of all
Providing laying and jointing in true line and level 50mm dia. U.P.V.C.
Pipe ( SCH- 40) for cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the wall with the help of
247 clamp at every two metre C/C or shall be concealed as directed Rmt 193.73
including necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost of all
Providing, laying and jointing in true line and level 160 diametre
U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and
other end socketed with rubber ring, & fittings conforming to
ISI 14735-1999 of approved make for drainage system pipe line,
pipe shall be jointed with each other with rubber lubricant, pipe
248 shall be fixed on wall using of PVC clamp of the size 160 mm diametre Rmt 822.99
x 210 mm length x 196 mm heigh at every 2000 mm center to center
or shall be concealed in walls as directed including necessary
fittings such as bends, shoes etc. including testing of pipes
and joints and jointed with adhesive solvent cement including
cost of all materials.
Providing, laying and jointing in true line and level 110 diametre
U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and
other end socketed with rubber ring, & fittings conforming to
ISI 14735-1999 of approved make for drainage system pipe line,
pipe shall be jointed with each other with rubber lubricant, pipe
249 shall be fixed on wall using of PVC clamp of the size 110 mm diametre Rmt 826.88
x 149 mm length x 145 mm heigh at every 2000 mm center to center
or shall be concealed in walls as directed including necessary
fittings such as bends, shoes etc. including testing of pipes
and joints and jointed with adhesive solvent cement including
cost of all materials.
Providing and fixing PVC SWR Nahni trap IS 14735 for drain -
100 mm diameter with jali of the following nominal diameter of
self cleansing design with C.I scread down or hinged grating including
the cost of cutting and making good the walls.
Providing and fixing PVC SWR Nahni trap IS 14735 for drain -
75 mm diameter with jali of the following nominal diameter
of self cleansing design with C.I scread down or hinged grating
including the cost of cutting and making good the walls.
Providing and laying (to level or slopes) and jointing with stiff mixture
252 of Cement Mortar in proportion 1:1 Salt glazed stoneware pipes Rmt 241.22
including testing of pipes and joints complete.(A) 100mm dia.
Providing and laying (to level or slopes) and jointing with stiff mixture
253 of Cement Mortar in proportion 1:1 Salt glazed stoneware pipes Rmt 302.11
including testing of pipes and joints complete.(B) 150mm dia.
Providing and fixing S.W. gully trap with C.I. grating brick masonry
chamber and water tight C.I. cover with frame of 300mm x 300mm
size (inside) with standard weight.(i) Square mouth traps. (A)
100mm x 100mm size P type.
Providing and fixing S.W. gully trap with C.I. grating brick masonry
chamber and water tight C.I. cover with frame of 300mm x 300mm
size (inside) with standard weight.(i) Square mouth traps.(B) 150mm
x 100mm size P or R type
Providing laying (to level or slopes) and jointing reinforced
concrete Light duty non-pressure pipes I.S. class NP2 of the
following internal diameter with collars and butt ends prepared for
collar joints including testing of joints complete.(B) 150mm
Providing laying (to level or slopes) and jointing reinforced
concrete Light duty non-pressure pipes I.S. class NP2 of the
following internal diameter with collars and butt ends prepared for
collar joints including testing of joints complete.(C) 250mm
Providing laying (to level or slopes) and jointing reinforced
concrete Light duty non-pressure pipes I.S. class NP2 of the
following internal diameter with collars and butt ends prepared for
collar joints including testing of joints complete.(D) 300mm
Providing laying (to level or slopes) and jointing reinforced
concrete Light duty non-pressure pipes I.S. class NP2 of the
following internal diameter with collars and butt ends prepared for
collar joints including testing of joints complete.(E) 450mm
Providing laying (to level or slopes) and jointing reinforced
concrete Light duty non-pressure pipes I.S. class NP2 of the
following internal diameter with collars and butt ends prepared for
collar joints including testing of joints complete.(F) 500mm
Providing laying (to level or slopes) and jointing reinforced
261 concrete Light duty non-pressure pipes I.S. class NP2 of the Rmt
following internal diameter with collars and butt ends prepared for
collar joints including testing of joints complete.(G) 600mm
Providing laying (to level or slopes) and jointing reinforced
concrete Light duty non-pressure pipes I.S. class NP2 of the
following internal diameter with collars and butt ends prepared for
collar joints including testing of joints complete.(H) 900mm
Providing laying (to level or slopes) and jointing reinforced
concrete Light duty non-pressure pipes I.S. class NP2 of the
following internal diameter with collars and butt ends prepared for
collar joints including testing of joints complete.(K) 1000mm
Providing laying (to level or slopes) and jointing reinforced
concrete Light duty non-pressure pipes I.S. class NP2 of the
following internal diameter with collars and butt ends prepared for
collar joints including testing of joints complete.(M) 1200mm
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1 cement :2-
coarse sand : 4-graded stone aggregate 20mm nominal size)
foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick
bats 40 + 50mm size) inside plastering 15mm thick with
Cement Mortar 1:3 (1- Cement : 3-coarse sand) finished with a
floating coat of neat cement and making channels in cement
concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate
265 20mm nominal size) finished smooth complete including curing and Each 76
festing (i) Inside size 900mm x 1200mm and 1.5M. deep including
C.I. cover with frame size 560mm diameter total weight of cover
and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of
frame 64 Kg.)(A) With 230mm thick walls of brick msonry using
brick having crushing strength not less than 35Kg. / Sq.cm.
in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (1) A type
depth 0.90 Metre for 150mm diameter sewer.
(A) With 230mm thick walls of brick msonry using brick having
crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar
1:5 (1- Cement: 5-Coarse sand) (4) D type depth 3.15 Metre for
150mm diameter sewer.
(I) Extra rate for constructing B.B. masonry for every additional
267 depth of 0.1M. or Part thereof over item No.265 (I) for depth Each 517.78
from 0.9M to 1.5M.
(II) Extra rate for constructing B.B. masonry for every additional
268 depth of 0.1M. GR Part thereof over item No.265 (I) for depth Each 393.26
from 1.50M. to 2.25M.
Providing and fixing cast iron steps of size 500mm x 150mm x
269 22.5mm and painting with two coats of Anti- corrosive paint etc. Each 201.74
Supplying and fixing C.I. cover 300mm x 300mm without frame for
270 Gulley trap (Standard pattern) te weight of cover to be not less Each 491.80
Constructing brick masonry chamber for underground C.I.
Inspection chamber and bends with bricks having crushing
strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with frame
(Light duty) 455mm x 610mm intenal dimensions total weight of
cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.)
271 and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix Each
(1-cement :2- coarse sand :4-graded stone aggregate 20mm
size) foundation concrete 1:5:10 inside plaster 15mm thick with
cement mortar 1:3 finished smooth with a floating coat of neat
cement on walls and bed concrete etc. complete.(i) Inside
dimensions 455mmx 610mm and 450mm deep for single pipe line.
Constructing brick masonry chamber for underground C.I.
Inspection chamber and bends with bricks having crushing
strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with frame
(Light duty) 455mm x 610mm intenal dimensions total weight of
cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.)
and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-
cement :2- coarse sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick with
cement mortar 1:3 finished smooth with a floating coat of neat
cement on walls and bed concrete etc. complete.(ii) Inside
dimensions 500mm x 700 mm and 450mm deep for pipe line
with one or two inlets.
Constructing brick masonry chamber for underground C.I.
Inspection chamber and bends with bricks having crushing
strength not less than 35Kg/ Cm2 in C.M. 1:5 C.I. cover with
frame (Light duty) 455mm x 610mm intenal dimensions total
weight of cover with frame to be not less than 38Kg. (Wt. of cover
23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix
(1-cement: 2- coarse sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick with
cement mortar 1:3 finished smooth with a floating coat of neat
cement on walls and bed concrete etc. complete.(iii) Inside
dimensions 600mm x 850 mm and 450mm deep for pipe lines with
three or more inlets.
Extra over items 271 for every additional depth of 0.1M. of part
274 thereof beyond 450mm depth for Brick masonry chamber.(i) for Each 239.99
455mm x 610mm size.
Extra over items 272 for every additional depth of 0.1M. of part
275 thereof beyond 450mm depth for Brick masonry chamber.(ii) for Each 262.24
500mm x 700mm size.
Extra over items 273 for every additional depth of 0.1M. of part
276 thereof beyond 450mm depth for Brick masonry chamber.(iii) for Each 322.37
600mm x 850mm size.
(A) Providing sock pit of 2.00 Cu.M. Volume including excavating
and filling brickbats with dry masonry work at top for 45cm.
height including covering the top with stone including providing vatas
in C.M. 1:3 with finishing curing etc. complete as directed.
(B) Providing sock pit of 5.00 Cu.M. Volume including excavating
and filling brickbats with dry masonry work at top for 45cm. 3327..4
height including covering the top with stone including providing vatas
in C.M. 1:3 with finishing curing etc. complete as directed.
Earthwork for embankment including breaking clods, dressing
279 with all lead and lift (excluding watering and consolidation)(A) Each 103.17
From Borrow pits within land width
Earthwork for embankment including breaking clods, dressing
280 with all lead and lift (excluding watering and consolidation)(B) cu.m 146.04
From Borrow area within 0.5 Km.lead
Earthwork for embankment including breaking clods, dressing
281 with all lead and lift (excluding watering and consolidation)(C) cu.m 148.90
From Borrow area within 1.0 Km.lead
Earthwork for embankment including breaking clods, dressing
282 with all lead and lift (excluding watering and consolidation)(D) cu.m 154.35
From Borrow area within 2.0 Km. lead
Earthwork for embankment including breaking clods, dressing
283 with all lead and lift (excluding watering and consolidation)(E) cu.m 159.62
From Borrow area within 3.0 Km. lead
Rolling of earthwork in layers with power roller including filling in
depressions which occur during the process.
285 Watering of earth work as directed. cu.m 8.99
Earthwork for embankment including breaking clods, dressing
with all lead and lift and including watering rolling and
286 consolidation of subgrade in layers at O.M.C. to required dry density cu.m 151.00
including filling the depression which occur during the process using
power roller 8T to 10T.(A) From Borrow pits within land width
Earthwork for embankment including breaking clods, dressing
with all lead and lift and including watering rolling and
287 consolidation of subgrade in layers at O.M.C. to required dry density cu.m 154.18
including filling the depression which occur during the process using
power roller 8T to 10T.(B) From Borrow area within 0.5KM. lead
Earthwork for embankment including breaking clods, dressing
with all lead and lift and including watering rolling and
288 consolidation of subgrade in layers at O.M.C. to required dry density cu.m 157.04
including filling the depression which occur during the process using
power roller 8T to 10T.(C) From Borrow area within 1.0KM. lead
Earthwork for embankment including breaking clods, dressing
with all lead and lift and including watering rolling and
289 consolidation of subgrade in layers at O.M.C. to required dry density cu.m 162.48
including filling the depression which occur during the process using
power roller 8T to 10T.(D) From Borrow area within 2.0KM. lead
Earthwork for embankment including breaking clods, dressing
with all lead and lift and including watering rolling and
290 consolidation of subgrade in layers at O.M.C. to required dry density cu.m 167.76
including filling the depression which occur during the process using
power roller 8T to 10T.(E) From Borrow area within 3.0KM. lead
Earthwork in cuting in all sorts of soil and soft murrum including
conveying and spreading the stuff, embankment as and
where directed within 200meters from the end of the cutting
with all required lead and lift.
Earthwork in cuting in all sorts of soil and soft murrum including
conveying and spreading the stuff, embankment as and
292 where directed within 200meters from the end of the cutting cu.m 35.60
with all required lead and lift.(A) Above 200 Meters upto
Earthwork in cuting in all sorts of soil and soft murrum including
conveying and spreading the stuff, embankment as and
293 where directed within 200meters from the end of the cutting cu.m 52.77
with all required lead and lift.(B) Above 300 Meters upto
Earthwork in cuting in all sorts of soil and soft murrum including
conveying and spreading the stuff, embankment as and
294 where directed within 200meters from the end of the cutting cu.m 88.52
with all required lead and lift.(C) Above 400 Meters upto
Earthwork in cutting in all sorts of soil and soft murrum including
conveying and putting the stuff in spoil bank maintaining
minimum distance of five meter between top edge and cutting and
toe of spoil bank.
Box cutting the road surface to proper slope and camber for making a
base for road work including removing the excavated stuff and
depositing on the road side slope as
directed upto 50Mt.lead.
Earthwork in cutting including preparing the slope and camber
andstacking or utilising the cutting stuff in bank as directed upto
200 Meters from the end of cutting with all lead and lift.(i) Hard
Earthwork in cutting including preparing the slope and camber
andstacking or utilising the cutting stuff in bank as directed upto
200 Meters from the end of cutting with all lead and lift.(ii) Soft
rock not requiring blasting.
Earthwork in cutting including preparing the slope and camber
andstacking or utilising the cutting stuff in bank as directed upto
200 Meters from the end of cutting
with all lead and lift.(iii) Hard rock.
Suppliying of graded stone aggregate of following sizes (for
300 W.B.M. Road)(1) Hand broken stone aggregate25mm to 90mm cu.m 246.53
Suppliying of graded stone aggregate of following sizes (for
301 W.B.M. Road)(2) Hand broken stone aggregate 40 mm to 63 mm cu.m 289.28
Suppliying of graded stone aggregate of following sizes(for
302 W.B.M. Road)(3) Crushed stone aggregate for Hard Quality up to cu.m 417.53
Supplying of crushed stone aggregates, chippings etc. of hard stone
of following nominal size free of disintegrated pieces
deletarious and oraganic mater (for Bitumen surface dressing etc.)
and grading as per I.R.C. Code.(ii) 40mm
Supplying of crushed stone aggregates, chippings etc. of hard stone
of following nominal size free of disintegrated pieces
deletarious and oraganic mater (for Bitumen surface dressing etc.)
and grading as per I.R.C. Code.(iv) 20mm
Supplying of crushed stone aggregates, chippings etc. of hard stone
of following nominal size free of disintegrated pieces
deletarious and oraganic mater (for Bitumen surface dressing etc.)
and grading as per I.R.C.Code.(vii) 6mm
306 Supplying of brick aggregate 40mm nominal size. cu.m 200.00
Supplying of screened cleaned pea (rounded) gravel of following
sizes)(i) 10mm nominal size.
Supplying of screened cleaned pea (rounded) gravel of following
sizes)(ii) 12mm nominal size.
Supplying of screened cleaned pea (rounded) gravel of following
sizes)(B) Supplying of unscrened gravel
310 Supplying promoulded bituminous joint filler.(i) 12mm thick cu.m 548.31
Spreading the stone aggregate for rolling and W.B.M. including
311 filling the interstices to required camber and gradient (excluding cu.m 247.28
spreading of Blindage)(ii) 40mm to 63mm size aggreagates (H.B.)
Spreading the stone aggregate for rolling and W.B.M. including
312 filling the interstices to required camber and gradient (excluding cu.m 247.28
spreading of Blindage)(iii) 25mm to 50mm size crushed stone
Spreading the stone aggregate for rolling and W.B.M. including
filling the interstices to required camber and gradient (excluding
spreading of Blindage)(iv) Chipping varying from 6mm to 25mm
Spreading blindage or road crust filling the gaps in metal and leveling
to camber and gradient as directed.(i) Murrum
Spreading blindage or road crust filling the gaps in metal and leveling
to camber and gradient as directed.(ii) Sand
Rolling and consolidation of soling including filling in depression
316 which occur during the process, with power roler 8 tonne to 12 cu.m 22.14
Rolling and consolidating water bound macadam (except laterite and
Kankar) including watering not exceeding 150mm thickness (Main
317 layer including binding materials ) including filling in depressions Sqm 20.79
which occur during the process.(A) With power roller exceeding
tonne and not exceeding 12 tonne.
Preparing surface by Brushing with wire brushes for removing
caked mud etc. sweeping with brooms and finally fanning the
cleaned surface with gunney bags to remove all loose dirt etc.(i)
Water bound macadam surface (New)
Preparing surface by Brushing with wire brushes for removing
caked mud etc. sweeping with brooms and finally fanning the
cleaned surface with gunney bags to remove all loose dirt etc.(ii)
Black top surface.
Providing and supplying evenly priming / tack coat with bitumen @
320 rate of 10 Kg/ Sq.M. (including heating the bitumen but excluding Sqm 6.62
the cost of bitumen)
Add/Deduct for any item of bituminious work for extra/less
use of bitumen (including heating)
Surface dressing one coat with paving bitumen using 18kg.
bitumen per 10.0 Sq.M. with 0.15 cu.m. of stone chipping 12mm
322 nominal size per 10.0 Sq.M. of road surface excluding roling Sqm 19.70
and consolidation (stone chipping and bitumen shall be paid
Surface dressing two coat with bitumen using 18kg. bitumen per
10.0 Sq.M. with 0.15 cu.m. of stone chipping 12mm nominal
size per 10.0 Sq.M. for first coat and 11 Kg. of bitumen with
323 cu.m. of stone chippings 10mm nominal size per 10 Sq.M. of road Kg 20.96
surface for second coat excluding consolidation for second
coat excluding consolidation bitumen shall be paid
Surface dressing enewal coat with paving bitumen or tar using 11kg.
of bitumen of 12Kg. of cut-back or road tar per ten 10.0 Sq.M. with
324 0.10 cu.m. of stone chipping 10mm nominal size per 10.0 Sqm 14.03
Sq.M. of road surface excluding roling and consolidation (Chips
and bitumen shall be paid seperately)
Add to or deduct from any item of bituminious work for variation in
quantity of stone chippings (Labour only)
2cm. thick open - graded pre-mix carpet surfacing with
cu.m. stone chippings (12mm size 0.18cu.m. and 10mm size
cu.m.) mixed with 14.4 kgs. of bitumen per 10 Sq.M. of road
surface excluding rolling and consolidetion etc. complete.
(Stone chippings and Bitumen shall be paid separately)(i)
With tack coat at rate of 5.0 Kg. /10 Sq.M.
2.5cm. thick Consolidated singlecourse pre-mixed carpet
surfacingwith 0.36 cu.m. of stone chippings(20mm size 0.15cu.m.
10mm size0.12 cu.m. and 0.6 mm size of 0.09 cu.m. ) mixed with
327 kgs. ofbitumen per 10 Sq.M. of road surface excluding cu.m
consolidetion etc. complete.(Stone chippings and Bitumen
shall bepaid separately)(i) With tack coat at rate of 5.0 Kg.
Liquid seal coat (IRC type -A) with 0.09 cu.m. of stone chippings
328 6mm size and 6.8Kg. of bitumen per 10.0 Sq.M. of road cu.m
surface excluding rolling and consolidation. (Chipping and
bitument shall be paid seperately)
Pre-mixed seal coat (I.R.C. type-B) with 0.06 cu.m. of fine aggregate
and 6.8 Kg. of bitumen per 10 Sq.M. of road surface excluding
rolling and consolidetion. (Chipping and bitument shall be paid
Pre-mixed seal coat with 0.12 cu.m. of stone chippings 10mm
size and 7.68 Kg. of bitumen per 10 Sq.M. of road surface excluding
rolling and consolidetion. (Stone chipping and bitument shall be
paid separately)
Laying built-up spray grout base course intwo layers with bitumen at
rate of 15 kg./per 10 Sq.M. with 0.50 cu.m. stone aggregate for first
layer and 15kg. of bitumen and
331 0.50 cu.m. of stone aggregate per 10 Sq.M. of roadsurface cu.m 24.74
for second layer and using 0.13cu.m. of Key aggregate per
Sq.M. excluding rolling and consolidation complete. (stone
aggregate and bitumen shall be paid separately)
Labour charges for laying premixed bituminious macadam /
concrete / carpet etc. by hot mix laid process including heating the
asphalt and aggregates by continuous hot mix,transporting the
mix and spreading the same by paverfinisher and
332 consilidation with powerroller including providing and Sqm 489.54
layinguniformaly tack coat includingproviding and laying
uniformaly tackcoat including necessary fire wood oillubricants,
labour charges and hirecharges of the required plant
andmachineries etc. complete.
Consolidation of surface dressing in one coat with power roller
including cost of fuel hire charges of roller etc. complete.
Consolidation of surface dressing in two coats with power
roller including cost of fuel hire charges of roller etc. complete.
Consolidation of 2cm. thick open graded premixed asphalt
335 carpet with power roller including cost of fuel hire charges of Sqm 10.25
roller etc. complete.
Consolidation of 2.5cm. thick premixed asphalt carpet with
336 power roller including cost of fuel hire charges of roller etc. Sqm 10.25
Consolidation of liquid / premixed seal coat with power roller
including cost of fuel hire charges of roller etc. complete.
Consolidation of Built up spray grout in required layers with
338 power roller including cost of fuel hire charges of roller etc. Sqm 11.82
Consolidation of bituminous macadam / concrete etc. with
339 power roller including cost of fuel hire charges of roller etc. Sqm 15.12
Supplying and fixing road sign board of M.S. plates and angle
iron including painting, lettering etc. complete including fixing in
C.C. 1:4:8 with necessary excavation etc. complete as per I.R.C.
type design.(i) Non - Reflective type
Supplying and fixing road sign board of M.S. plates and angle
iron including painting, lettering etc. complete including fixing in
C.C. 1:4:8 with necessary excavation etc. complete as per I.R.C. type
design.(ii) Reflective type
Providing and fixing Junction board of precast R.C.C. as per
342 standard I.R.C. design including fixing in C.C. with 1:4:8 necessary Each
excavation painting figuring and lettering on board etc. complete.
Providing and fixing Junction board of M.S. plates and angles as
per standard I.R.C. design including fixing in C.C. 1:4:8 with
necessary excavation painting figuring and lettering on board etc.
Labour charges for dry stone pitching 15 cm. Thick including
preparing the surface.
Labour charges for dry stone pitching of 22.5 cm. thick including
preparing the surface etc complete.
Labour charges for dry stone pitching of 20.0 cm. thick including
preparing the surface etc complete.
Providing panel wall for dry stone pitching in uncourased rubble
347 masonary with had stone of approved quality in cement. mortar 1.5 Sqm
including curing etc, complete.
Scarifying gravelled macadam or bitumen macadam surface
348 cm to 10 cm.depth including stacking useful materials on road side cu.m 39.23
and disposing off remaining stuff.
Labour charges for filling measure boxes of crushed metal or
349 gravel of size 20 mm to 63 mm including all tools and as Sqm 101.91
Labour charges for filling measure boxes of Kapachi of 12 m.size Grit,
sand, murrum etc. including all tools and as directed.
Labour charges for breaking boulders and Big.size rubble in to
oversize metal for soling.
Labour charges for breaking boulders and Big.size rubble in to
standard size. (40mm to 63 mm) metal for soling.
Supplying of wooden pegs 4 cm. in Diameter and 25 cm. to 30 cm.
long including taper at one end etc. complete.
Demarkation of road alingment including marking out road line
by providing and fixing wooden pegs or steel rod of required
354 size at every 25 M to 50 M. including excavating trenches ion Each
both sodes of 0.30 m. x 0.30M. including supplying of labours and all
materials for every work etc. complete.
Filling around the pipes with murrum including dressing, tampering
Providing and fixing 20cm. x 15cm x 2.5 cm. thick year plate of
356 marble stone set in C.M. 1:4 including finishing and engraving letters cu.m 276.92
Numbering the C.D. work with approved paint including all materials
for painting etc. complete.
Providing and fixing Number plate of Marble plate stone of required
358 size set in C.M. 1:4 including finishing and engeaving letters etc. Each 303.11
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
in C.M. 1:2 watering and laying (to level or slope) of I.S. class NP2
of following internal diameters.(i) 300mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
in C.M. 1:2 watering and laying (to level or slope) of I.S. class NP2
of following internal diameters.(ii) 450mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
in C.M. 1:2 watering and laying (to level or slope) of I.S. class NP2
of following internal diameters.(iii) 600mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
in C.M. 1:2 watering and laying (to level or slope) of I.S. class NP2
of following internal diameters.(iv) 800mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
in C.M. 1:2 watering and laying (to level or slope) of I.S. class NP2
of following internal diameters.(v) 900mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
in C.M. 1:2 watering and laying (to level or slope) of I.S. class NP2
of following internal diameters.(vi)1100mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
in C.M. 1:2 watering and laying (to level or slope) of I.S. class NP2
of following internal diameters.(vii) 1200mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts carrying heavy traffic as per IS 458-
366 1991 specifications including setting the pipes in C.M. 1:2 watering Rmt 643.49
and laying (to level or slopes) of class NP3 of following internal
daimeters.(i) 300mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts carrying heavy traffic as per IS 458-
367 1991 specifications including setting the pipes in C.M. 1:2 watering Rmt
and laying (to level or slopes) of class NP3 of following internal
daimeters.(ii) 450mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts carrying heavy traffic as per IS 458-
368 1991 specifications including setting the pipes in C.M. 1:2 watering Rmt
and laying (to level or slopes) of class NP3 of following internal
daimeters.(iii) 600mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts carrying heavy traffic as per IS 458-
369 1991 specifications including setting the pipes in C.M. 1:2 watering Rmt
and laying (to level or slopes) of class NP3 of following internal
daimeters.(iv) 750mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts carrying heavy traffic as per IS 458-
370 1991 specifications including setting the pipes in C.M. 1:2 watering Rmt
and laying (to level or slopes) of class NP3 of following internal
daimeters.(v) 900mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts carrying heavy traffic as per IS 458-
371 1991 specifications including setting the pipes in C.M. 1:2 watering Rmt
and laying (to level or slopes) of class NP3 of
following internal daimeters.(vi)1050mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts carrying heavy traffic as per IS 458-
372 1991 specifications including setting the pipes in C.M. 1:2 watering Rmt
and laying (to level or slopes) of class NP3 of following internal
daimeters.(vii) 1200mm dia.
Cautionary Warning Sign :-Providing and fixing sign boards
made out of 2mm aluminium sheet / 4mm ACP (Aluminum
composite Panel); size 90 x 90 x 90 cms. equilateral triangle as
per design of IRC-67-2012. Pre treated with phospheting process &
acid etching; coated with one coat of epoxy primer and two coats
of best quality epoxy paint ;reflectorised with Micro Prismatic
Grade retro refiectivesheeting of Type-11 as per ASTM D 4956 and
latest M.O.S.T.Specifications; 3.6mtr long stand post of 75 x 75 x
6mm / 65NB Circular MS Pipe as required and frame fabricated
373 from suitable size iron angle of 35 x 35 x 3mm; painted with Rmt
bestquality epoxy coatings in black and white bends. The details of
symbol foreach board shall be as per theinstruction of engineer in
charge. The fixing at site shall be in 1:2:4 CC blockof size 45 x 45 x
60 Cms. for each leg.including excavation, curing etc.complete under
the supervision of engineer in charge. A warranty for 10 years for the
Retro reflective sheeting from original manufacturer & a certified
copy of 3 year outdoor exposure test report from third party test lab
for the product offered shall be submitted by contractor. (A)
Class-C Type-11 Retro Reflective sheeting
Facility Informatory Sign :-Providing and fixing sign boards
made out of 2mm aluminium sheet / 4mm ACP (Aluminum
composite Panel); size 80 x 60 cms rectangular as per
design of IRC-67-2012. Pre treated with phospheting process &
acid etching; coated with one coat of epoxy primer and two coats of
best quality epoxy paint ;reflectorised with Micro Prismatic Grade
retro refiectivesheeting of Type-11 as per ASTM D-4956 and latest
M.O.S.T.Specifications; 3.6mtr long stand post of 75 x 75 x 6mm /
65NB Circular MS Pipe as required and frame fabricated from
suitable size iron angle of 35 x 35 x 3mm; painted with bestquality
epoxy coatings in black and white bends. The details of symbol
foreach board shall be as per theinstruction of engineer in
charge. The fixing at site shall be in 1:2:4 CC blockof size
45 x 45 x 60 Cms. for each leg.including excavation, curing
etc.complete under the supervision of engineer in charge. A warranty
for 10 years for the Retro reflective sheeting from original
manufacturer & a certified copy of 3 year outdoor exposure test
report from third party test lab for the product offered shall be
submitted by contractor. (A) Class-C Type-11 Retro Reflective
Regulatory / Mandatory Sign :-Providing and fixing sign boards
made out of 2mm aluminium sheet / 4mm ACP (Aluminum
composite Panel); size 60 cms Dia Circle as per design of IRC-67-
2012. Pre treated with phospheting process & acid etching; coated
with one coat of epoxy primer and two coats of best quality
epoxy paint ;reflectorised with Micro Prismatic Grade
retro refiectivesheeting of Type-11 as per ASTM D-4956 and latest
M.O.S.T.Specifications; 3.6mtr long stand post of 75 x 75 x 6mm /
375 65NB Circular MS Pipe as required and frame fabricated from suitable Each
size iron angle of 35 x 35 x 3mm; painted with bestquality epoxy
coatings in black and white bends. The details of symbol foreach
board shall be as per theinstruction of engineer in charge. The fixing
at site shall be in 1:2:4 CC blockof size 45 x 45 x 60 Cms. for each
leg.including excavation, curing etc.complete under the
supervision of engineer in charge. A warranty for 10 years for the
Retro reflective sheeting from original manufacturer & a certified
copy of 3 year outdoor exposure test report from third party test lab
for the product offered shall be submitted by contractor. (A)
Class-C Type-11 Retro Reflective sheeting
STOP Sign :-Providing and fixing sign boards made out of 2mm
aluminium sheet / 4mm ACP (Aluminum composite Panel); size
cms Octagone as per design of IRC-67- 2012. Pre treated with
phospheting process & acid etching; coated with one coat of
epoxy primer and two coats of best quality epoxy paint
;reflectorised with Micro Prismatic Grade retro refiectivesheeting
11 as per ASTM D-4956 and latest
M.O.S.T.Specifications; 3.6mtr long stand post of 75 x 75 x 6mm /
65NB Circular MS Pipe as required and frame fabricated from
376 suitable size iron angle of 35 x 35 x 3mm; painted with Each
bestquality epoxy coatings in black and white bends. The details
of symbol foreach board shall be as per theinstruction of engineer
in charge. The fixing at site shall be in 1:2:4 CC blockof size 45 x 45 x
60 Cms. for each leg.including excavation, curing
etc.complete under the supervision of engineer in charge. A
warranty for 10 years for the Retro reflective sheeting from original
manufacturer & a certified copy of 3 year outdoor exposure test
report from third party test lab for the product offered shall be
submitted by contractor. (A) Class-C Type-11 Retro Reflective
Parking Sign :-Providing and fixing sign boards made out of 2mm
aluminium sheet / 4mm ACP (Aluminum composite Panel); size
size 60 x 60cms. square plus 60 x 20cms rectangular additional plate
as as per the design of IRC-67-2012. Pre treated with phospheting
process & acid etching; coated with one coat of epoxy primer and two
coats of best quality epoxy paint ;reflectorised with Micro Prismatic
Grade retro refiectivesheeting of Type- 11 as per ASTM
D-4956 and latest M.O.S.T.Specifications; 3.6mtr long stand
post of 75 x 75 x 6mm / 65NB Circular MS Pipe as required and
frame fabricated from suitable size iron angle of 35 x 35 x 3mm;
painted with bestquality epoxy coatings in black and white
bends. The details of symbol foreach board shall be as per
theinstruction of engineer in charge. The fixing at site shall be in 1:2:4
CC blockof size 45 x 45 x 60 Cms. for each leg.including
excavation, curing etc.complete under the supervision of
engineer in charge. A warranty for 10 years for the Retro reflective
sheeting from original manufacturer & a certified copy of 3 year
outdoor exposure test report from third party test lab for the
product offered shall be submitted by contractor. (A) Class-C
Type-11 Retro Reflective sheeting
Distance Informatory / Destination Sign :-Providing and fixing sign
boards made out of 2mm aluminium sheet / 4mm ACP
(Aluminum composite Panel); size 180x120 cms. rectangular as
per design of IRC-67-2012. Pre treated with phospheting process
& acid etching; coated with one coat of epoxy primer and two
coats of best quality epoxy paint ;reflectorised with Micro
Prismatic Grade retro refiectivesheeting of Type-11 as per ASTM D
4956 and latest M.O.S.T.Specifications; 4.0mtr long (2 Nos.) stand
post of 75 x 75 x 6mm / 65NB Circular MS Pipe as required and
frame fabricated from suitable size iron angle of 50 x 50 x 5mm;
painted with bestquality epoxy coatings in black and white bends.
The details of symbol foreach board shall be as per theinstruction
of engineer in charge. The fixing at site shall be in 1:2:4 CC blockof
size 45 x 45 x 60 Cms. for each leg.including excavation, curing
etc.complete under the supervision of engineer in charge. A warranty
for 10 years for the Retro reflective sheeting from original
manufacturer & a certified copy of 3 year outdoor exposure
test report from third party test lab for the product offered shall be
submitted by contractor. (A) Class-C Type-11 Retro Reflective
Village Name Sign :-Providing and fixing sign boards made out
of 2mm aluminium sheet / 4mm ACP (Aluminum composite
Panel); size 90x60 cms. rectangular as per design of IRC-67-
2012. Pre treated with phospheting process & acid etching;
coated with one coat of epoxy primer and two coats of best quality
epoxy paint ;reflectorised with Micro Prismatic Grade retro
refiectivesheeting of Type-11 as per ASTM D-4956 and latest
M.O.S.T.Specifications; 3.3mtr long stand post of 75 x 75 x 6mm /
65NB Circular MS Pipe as required and frame fabricated from
suitable size iron angle of 35 x 35 x 3mm; painted with bestquality
epoxy coatings in black and white bends. The details of
symbol or inscription/letters / numerals for each board shall be as
per the instruction of engineer in charge. The fixing at site shall
be in 1:2:4 CC blockof size 45 x 45 x 60 Cms. for each leg.including
excavation, curing etc.complete under the supervision of engineer in
charge. A warranty for 10 years for the Retro reflective sheeting
from original manufacturer & a certified copy of 3 year
outdoor exposure test report from third party test lab for the
product offered shall be submitted by contractor. (A) Class-C
Type-11 Retro Reflective sheeting
Sign board per Squate Meter :-Providing and fixing sign boards
made out of 2mm aluminium sheet / 4mm ACP (Aluminum
composite Panel); size 1meter x1 meter as per design of IRC-67-
2012. Pre treated with phospheting process & acid etching; coated
with one coat of epoxy primer and two coats of best quality
epoxy paint ;reflectorised with Micro Prismatic Grade
retro refiectivesheeting of Type-11 as per ASTM D-4956 and latest
M.O.S.T.Specifications; 4 mtr long stand post (2 Nos.) of 75 x 75
x 6mm / 65NB Circular MS Pipe as required and frame
fabricated from suitable size iron angle of 50 x 50 x 5mm; painted
with bestquality epoxy coatings in black and white bends. the details
of symbol or inscription / numerals for each board shall be as per the
instruction of engineer in charge.The fixing at site shall be in
1:2:4 CC blockof size 45 x 45 x 60 Cms. for each leg.including
excavation, curing etc.complete under the supervision of engineer in
charge. A warranty for 10 years for the Retro reflective sheeting
from original manufacturer & a certified copy of 3 year
outdoor exposure test report from third party test lab for the
product offered shall be submitted by contractor. (A) Class-C
Type-11 Retro Reflective sheeting
Men at work (2' x 2') sign :-Providing and fixing sign boards
made out of 2.0 mm aluminium sheet / 4 mm ACP(Aluminum
composite Panel); size 60cm x 60cm square as per design of
IRC-67-2012. Pre treated with phospheting process & acid
etching; coated with one coat of epoxy primer and two coats of best
quality epoxy paint ;reflectorised with Micro Prismatic Grade retro
refiectivesheeting of Type-11 as per ASTM D-4956 and latest
M.O.S.T.Specifications; 3.3 mtr long stand post of 75 x 75 x 6mm /
65NB Circular MS Pipe as required and frame fabricated from suitable
size iron angle of 50 x 50 x 5mm; painted with bestquality epoxy
coatings in black and white bends. the details of symbol or
inscription / numerals for each board shall be as per the instruction
of engineer in charge.The fixing at site shall be in 1:2:4 CC blockof
size 45 x 45 x 60 Cms. for each leg.including excavation, curing
etc.complete under the supervision of engineer in charge. A warranty
for 10 years for the Retro reflective sheeting from original
manufacturer & a certified copy of 3 year outdoor exposure
test report from third party test lab for the product offered shall be
submitted by contractor. (A) Class-C Type-11 Retro Reflective
Tree Guard sign :-Providing & fixing sign board made out of 2mm
aluminium sheet / 3mm ACP (Aluminum composite Panel)
size 30cms diameter circle, pretreated with phospheting
process and acid etching, painted with one coat of epoxy primer
and two coats of best quality epoxy paint reflectorised with
382 retro reflective sheeting as per latest M.O.S.T. specifications. A Each 526.00
warranty for 10 years for the Retro reflective sheeting from
original manufacturer & a certified copy of 3 year outdoor
exposure test report from third party test lab for the product
offered shall be submitted by contractor.
(A) Class-C Type-11 Retro Reflective sheeting
Diversion sing board :-Providing & Fixing sign boards made out
of 2mm aluminium sheet, size 180 x 60 cms. rectangle as per the
attached drawing pre treated with phospheting process & acid
etching. coated with one coat of epoxy priemr and two coats of best
quality epoxy paint reflectorised with retro reflective sheeting as
per latest M.O.S.T. Specifications; Letters and numerals should
be as per IRC-30-1968,3.1m long (2nos) stand post and frame
fabricated from iron angle of 35x35x3mm, 50x50x5mm
painted with best quality epoxy coatings in blak and white bends.
The fixing at site shall be in 1:2:4 CC block of size 45 x 45x 60cms for
each leg, including excavation curing etc. complete under the
supervision of engineer in charge.(A) Engineer Grade(VR)...
Clearing and grubbing road land including uprooting rank vegetation
grass bushes,shrubs,sapling and trees girth up to 300 mm removal Hectar
of stumps of trees cut earlier and disposal of unserviceable e
materials(A) By manual means in area of light jungle
Clearing and grubbing road land including uprooting rank vegetation
grass bushes,shrubs,sapling and trees girth up to 300 mm removal Hectar
of stumps of trees cut earlier and disposal of unserviceable e .93
materials (C) By mechanical means in area of light jungle
Rolling and consolidation using vibratory road roller 8 - 10 tonne
386 capacity (incl. watering)(A) Earth work (layer not exceeding cu.m 32.76
200mm thickness)
Rolling and consolidation using vibratory road roller 8-10 tonne
387 capacity (B) Granular sub base(Layer not exceeding 150mm cu.m 31.20
Rolling and consolidation using vibratory road roller 8 - 10 tonne
388 capacity (C) Water bound Macadam (Layer not exceeding 100mm cu.m 58.50
Rolling and consolidation using vibratory road roller 8 - 10 tonne
389 capacity (D) Bituminous Macadam (Layer not exceeding 50mm cu.m 20.30
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971
Class NP3 of following internal diameter. 1400 mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971
Class NP3 of following internal diameter. 1600 mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971
Class NP3 of following internal diameter. 1800 mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
393 in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971 Rmt
Class NP3 casted by vertically vibrated technology of following
internal diameter. (i) 300 mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
394 in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971 Rmt
Class NP3 casted by vertically vibrated technology of following
internal diameter. (ii) 450 mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
395 in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971 Rmt
Class NP3 casted by vertically vibrated technology of following
internal diameter. (iii) 500 mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
396 in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971 Rmt
Class NP3 casted by vertically vibrated technology of following
internal diameter. (iv) 600 mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
397 in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971 Rmt
Class NP3 casted by vertically vibrated technology of following
internal diameter. (v) 900 mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
398 pipes with collars for culverts including setting and joining the pipes Rmt
in C.M. 1:2 watering and laying (To level of slops of I.S. 458 /
Class NP3 casted by vertically vibrated technology of following
internal diameter. (vi) 1000 mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
399 in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971 Rmt
Class NP3 casted by vertically vibrated technology of following
internal diameter. (vii) 1200 mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
400 in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971 Rmt
Class NP3 casted by vertically vibrated technology of following
internal diameter. (viii) 1400 mm dia.
Supplying and fixing reinforced concrete heavy duty non- pressure
pipes with collars for culverts including setting and joining the pipes
401 in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971 Rmt
Class NP4 casted by vertically vibrated technology of following
internal diameter. 300mm dia.
Refitting of Existing Rough nimbhada paving work on Excavated
Pipeline, Gas line, Water Supply Line, Telephone Line, Drainage Line
Etc. Including of Lifting the the exsting stone paving work & make a
402 proper slope and camber for base supplying and stacking local sand Sqm 256.37
for bedding of 35 mm thick and filling the joint with cement pointing
in C.M. 1:4. all meterials (. Note : Rough Kota stone supplied by Nagar
Refitting of Existing Paver Block paving work on Excavated Pipeline,
Gas line, Water Supply Line, Telephone Line, Drainage Line Etc.
Including of Lifting the theexsting stone paving work & make a proper
slope and camber for base supplying and stacking local sand for
bedding of 35 mm thick and filling the joint with cement pointing in
C.M. 1:4. all meterials ( Note : Paver Block supplied by Nagar Palika )
Carting of rough nimbhada stone including loading and unloading as
per directed incharge engineer with all lead and lift
Providing and laying Precast Regular concrete solid core wall of
approved make & size of 40 mm thick, 600 mm wide and 1800 mm in
legth with 150 mm X 150 mm X 2400 mm post both side made from
405 of controlled cement concrete M35 having cube compressive Sqm
strength not less than 35 MPa jointing with high strength & tensile
adhesion non-shrink cementitious joint compound / P.U. Foam.
(Plaster not required)
Providing & Spreding floor hardner chemical of standard company on
the road surface as per directed engineers in charge. (market rate)
Compaction and finishing of cement concrete road by trimix process
providing extra labor charges for the trimix vacuum dewatering
407 service process on cement concrete road surface by using vacuum Sqm
dewatering pump floater surface vibrator including making groves
and rough finish to surface as per in including levelling the complete.
Raising Brick Masnoary chamber (In side dimension 600 mm x
mm) as per requirment including removal and re fitting of chamber 4200.0
frame & cover at proposed road level including all material and
labour charges as per instruction given by in charge enginneer.
Providing erecting and fixing double coated ISI water tank of
409 required capacity each with all necessary fittings and connection etc. litre
complete on terrace
Supplying and fixing cat eye (Stimsonite) made out from Acrilo
beautile sterine injuction high compressed molding with reflector
410 made of MMC (prismatic type of size 12cm x 6cm x 2.5cm) provided no
with bituminous adhesive 100g. with each unit for fixing. (High
Intensity grade)
Road marking with hot applied thermoplastic paints with
reflectorising glass beads on bitumin surface providing and laying a
hot applied thermoplastic compound 2.5 mm thick including
reflectorising glass beads @ 250gms per sqm area, thickness of
2.5mm is excluding of surface applied glass beds as per IRC:35-2015.
The finished surface to be level, uniform and free from streaks and
holes. zebra patta /bump patta lane/center line/ edge line/cut patta.
The white color marking should provide liminance coefficinet on
cemend road shalll be min 130 mcd/m2/lux and Asphalt road shall be
min 100 mcd/m2/lux during the service life during the day time. The
marking should meet the performance criteria for night time
reflectivity, wet reflectivity and skid resistance as mentioned in the
section-15 of IRC 35- 2015. Warranty for the Retro reflectivity should
Providing and fixing plastic , rubber heavy duty speed breaker
mm length, 400 mm width & 75 mm height , 40/50 ton 2750.0
bearing capacity & of standard make including cost of transportation.
All kind of lift & fixing etc. completed as directeed incharge engineer.
I/We am/ are willing to carry out to work @ _____________ % Above /Below ____________
Percentage (Should be written in Figures and Words) of the Estimated rates mentioned above
amount of my/ our Tender work out as under.
Estimated Amount Estimated Amount
Put On Tender Rs. 955448.00.00 Put On Tender Rs. 955448.00.00
Add % Rs Deduct % Rs.
Total Rs. Total Rs.
(In Words (In Words
Stamp With Signature of Mahemdabad Nagar
Mahemdabad Nagar Palika
Contractor Palika
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender Doc.pdf
SBD.pdf
01. ROAD WORKS BOOKLET Volume -.pdf
02. Building Specification Vollume-2.pdf
03. Pipeline Specification Volume-3.pdf
04. Electrical Specifications Volume- 4.pdf
Schedule-B.pdf
Download all tender documents and submit your bid