Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance CB 4190 SREE CHITHRA NAGAR PANGODE THIRUMALA P O THIRUVANANTHAPURAM 695 006 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695006 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹1.8 L
EMD Value
₹4,600
Closing Date
24 Feb 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Executive Engineer II
Office of the Assistant Executive Engineer, Engineering Unit, Subdivision II, Kariavattom
item rate
2025_KU_738730_1
AEE II/DBII/(e-GP)/E15(2)/2024-25
Open Tender
Electrical Works
Item Rate
45 days
kariavattom
Please refer Tender documents.
6 documents required · 6 mandatory
₹525
₹4,600
28 Feb 2025
15 Feb 2025
28 Feb 2025
15 Feb 2025
24 Feb 2025
15 Feb 2025
15 Feb 2025 - 24 Feb 2025
Amount
lights
od102407/2024_2025 : Supply, conveyance and erection of the lamp post made from 75/80 mm dia 'B' class GI pipe with 250x250x6mm MS anchor plate at the bottom on concrete base (excluding charges for concrete base and excavation) , drilling necessary holes for drawing wires,painting with 2 coats of best quality synthetic enamel paint over a coat of zinc chromate primer etc. as required.(The layout shall be obtained from the section office prior to the Fabrication Process)
od111470/2024_2025 : Suppy of following Flood light output > 105lumen/W 4000-6000 K with IP 66 protection with power factor >0.9 at full load, internal surge protection up to 8 KV, and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD <10%, power factor >0.9, RoHS compliant, duly wired up for use on 230 V AC supply as required. 20 W LED Flood light
od111471/2024_2025 : Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (Make Havells JETAIRISFLS100WLED757SYMLTG /Wipro/Crompton/Philips)
od207508/2024_2025 : Supply Conveyance, installation, testing and commissioning of 60W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance.(Make: Havells Jeta Quanto Plus/Crompton/Wipro/Philips)
od111561/2024_2025 : Supply and fixing the following sizes of Pole mounted junction box /cut-out box /fuse box of Sintex/Fibre reinforced plastic box of IP66 for road/street lighting with DIN rail for fixing MCB,Provision for fixing Neutral link for termination of cables,Fixing the same on lamp post using suitable size painted flat iron clamps with bolts and nut with washers etc..as required<br>300x200x105 MM
od111715/2024_2025 : Supply and providing sintex box with side hinged door of size 200x150x105mm with DIN rail for fixing MCB, provision for and including fixing neutral link for termination of cables, fixing the same on lamp post or nearby structure/ ground using suitable clamps bolts, nut washers etc including all accessories as required for complete installation
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
90.6.5.9 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sqmm.
90.12.5.38 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 4 sq mm
90.12.39.5 : Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 4 sq mm
1.14.9 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
od207498/2024_2025 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1Kv grade as required.&<br>4C x 4Sq. mm- <br>
90.12.5.41 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm.
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
90.16.1.9 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.64 mm GI conductor (12 SWG)
90.16.2.2 : Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class)
90.14.1.1 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00 mm CRCA sheet, powder coated (excluding base frame)
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
90.14.3.2 : Supply and providing heavy duty 'A' section neoprene gasket in the panel board U section rubber beeding suitable for 1.60/2.00 mm sheet.
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.12.10.2 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 50/38 mm or nearest size.
od111656/2024_2025 : Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing<br>masonry enclosure with cover plate having locking arrangement and watering pipe etc. with<br>charcoal/ coke and salt as required
14.1 : Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7 : Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.12 : Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
R.Radhakrishnan Nair (BID ID -2117908)
Bidder Name
R.Radhakrishnan Nair
ASOK ELECTRICALS
stage.html
html • 0.02 MB
finance_1186116.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .