Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance SANAT NAGAR SRINAGAR PIN 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | Rejected-Technical Annexure E not filled |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
9 Sept 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE EINGINEER MECHANICAL DIVISION KARGIL
Office of Executive Engineer Mech Div Kargil
Supply installation testing and commissioning of HSD fired Hot-water generator based Central Heating System at DFO office Baroo
2023_PWD_10922_1
MDK/e-NIT/09 of 2023-24
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
60 days
DFO office Baroo
Please refer Tender documents.
12 documents required · 12 mandatory
₹1,000
EXECUTIVE ENGINEER MECHANICAL DIVISION KARGIL
₹60,000
25 Sept 2023
4 Sept 2023
11 Sept 2023
4 Sept 2023
9 Sept 2023
4 Sept 2023
Amount
Design, Supply, Installation, testing and Commissioning of all necessary and integral component / equipments (or deemed necessary) as described here after. The scope of work includes the supply of DSITC of HWGs, radiator panels, Circulation pumps/ pipes, insulations, specialized valves, including construction of cement concrete foundation blocks of all equipments to provide fully automatic system capable of producing and maintaining high precision indoor conditions inside District Forest Officer Office Baroo, Kargil Taking into account of duration factors for atmospheric condition of Kargil @Alt: 2676m
HSD Fired, Horizontal Fire Tube type , Hot Water Generator fitted with combustion equipments, all boiler mountings- control panel, control valves, accessories including primary circulation pumps of suitable capacity and mono block pump set, including chimney of recommended dia, externally mounted at 8mtr above ground level. or as recommended by OEM. Complete in all respect. Job includes 01 No. spare burner assembly. Capacity of boiler= 1 lacKcal/ Hr
Hot water Circulation Pumps
Hot Water Circulation Mono-block Pump complete with electric motor of Single-Phase along-with common base frame duly grouted in cement concrete foundation. Discharge: 8 LPS at 25 m Head Rating= 3HP (aprox)
Oil Transfer Pumps
Gear Oil Transfer Pump with electric motor single phase rating along-with common base frame duly grouted in cement concrete foundation Capacity 2 LPS(min) @ 12 mtr Head
Soft water / Glycol Pumps
Soft Water Pump complete with electric motor of 1-ɸ, 230 V, 50 Hz, 1 HP rating along with common base frame duly grouted in cement concrete foundation. Capacity 2 LPS (min) at 12 m Head
Bulk Oil tank
Bulk oil tank of 6/8 mm MS plate with require red stiffener, manhole dully covered along-with unit to be laid underground with allied Civil Works, as per IOC specifications, Complete with required piping connections and valves. Capacity = 5 Kl x1No.
Day Oil Tank
Day oil tank of 4 MM M.S plate complete with 6 KW heating unit, manhole dully covered, Gauge Glass and structural support for mounting oil tank and ladder made out of tubular MS Section complete including standing structures. Capacity 500 litres,
Expansion Tank
Hot Water Expansion Tank of 4 mm M.S complete with manhole dully covered, necessary connections covered with 50 MM thick, 750 GSM Mikron insulation and finished with 24 Gauge Aluminum cladding and structural support for mounting of Expansion tank. Capacity 500 litres,
Soft Water Tank/ Glycol Water Tank
Soft water tank of HDPE (tripple layer) with necessary connections Capacity 500 litres
Hot Water Radiators Steel panel heating radiators conforming to EN442 with working pressure ranging from 10-13 bar having working temperature at 110°C ,complete with Top grilles and side covers as standard alongwith inlet valve, outlet valve, air purge valve and threaded plug as per OEM. Inlet Water Temp: 75oC Outlet Water Temp: 65oC Room Temp: 22oC
2000 Kcal/Hr (Double Panel Double Convector)
3000 Kcal/Hr (Double Panel Double Convector)
2000/3000 Kcal/Hr(Column type)
MS ERW pipe Mild steel ERW hot water piping of class ‘C’ (above/underground) complete with fittings like elbow, Tee, bends, flanges etc along-with structural supports as per norms and two coats of red oxide primer followed by two or more coats of bituminous paint complete in all respects. Insulation of hot water piping should be done with Elastomeric insulation of following thickness/ density. The above ground pipes running through the rooms, wards/ corridors boiler house etc shall be wrapped with two layers of polyethylene and chicken mess and covered with Aluminium cladding of 26 SWG. The underground pipes shall be shall be insulated with Elastometric insulation along wth Chicken mesh and tar felt.
80 mm DIA (50mm insulation)
50 mm DIA (50mm insulation)
40 mm DIA (50mm insulation)
32 mm DIA (50mm insulation)
20 mm DIA (50mm insulation)
Control Valve
Butterfly valve 80mm = 04 Nos. 50mm= 02 Nos. 32mm= 8 Nos. 20 mm = 04 Nos. Pressure Gauges Glycerine filled as per specifications (100 mm Dial) = 04 Nos. Thermometer as per specifications (100 mm Dial) = 04 Nos. Air release valves with isolation ball valves (25mm) = 04 Nos.
Control Panel Main Control Panel having separate cubicals for each equipment viz. isolation for Hot Water Generator 2No's , DOL Starter for Hot Water Circulation Pumps 2No's , Soft Water Pumps 2 No's (1 hp each), DOL starter Softener pump 1 No and for HSD Transfer Pump 2 No's, and On-Load Change Over Switch, MCCB The control panel shall be provided with the copper bus bars dully insulated of required ratings and 3 in 1 digital Voltmeter / Ammeter / Frequency meter, indicators etc. including multi-core armored copper conductor cables of required current rating from main panel board to various equipments to be laid over cable trays with appropriate clamps and fixing arrangements as per site conditions Including electric service cable of size = 70 sq.mm Al, Core-1=200 rm The current rating/sizes of electrical components of panel shall be in accordance with respective electrical loads of boilers/pumps etc.
Servo Voltage Stabilizer 3-phase, Oil cooled Servo Stabilizer micro processor controlled with high and low voltage cut off, single phase preventer, short circuit and over load protection having digital display.220 – 460 volts Phase to phase with panel as per specifications duly filled with recommended transformer oil upto full capacity
Capacity: 40 k-VA with input of 220-460 Volts Phase to phase and output of 415 volts ±1% phase to phase
Silent Diesel Generator Set, kVA
Silent Diesel Generator Set Output Rating: 25 KVA No. of Phase: 3 phase Type of Governor: Electronic / Mechanical Control Panel: AMF Additional Features: Fitted with cold starting kit
Earthing
Earthing for various equipments inside boiler house using copper plate electrode of size 500 x 500x 3 mm placed in 1000 x 1000x 1800 mm pit filled with charcoal & salt by copper strip of size 20 x 3 mm alongwith perforated G.I pipe.
Coolant
Providing and filling Coolant IOCL Servocool Plus Note: The quantity of anti-freeze is purely tentative.
Construction of Boiler house : construction of a Boiler House having 5-feet RCC foundation (3 feet below and 2 feet above ground), concrete brick masonry wall construction within an RCC column and beam framework, laying of a concrete floor with oil drainage provisions, installation of corrugated sheet roofing supported by a steel truss, electrification for lighting, quality interior paint application, and strict compliance with industry standards and local regulations. the scope includes the dismantling and disposal of an existing storeroom to create the requisite space for the Boiler House. Job is inclusive labors and materials, shuttering, tool tackles. Floor Size = 12’x15’x11’(height) with roller shutter door and suitable windows as per instruction of site engineer.
BHAT ENGINEERING WORKS
M/S MOHD MOHMAD KHAN
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .