Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹35.8 LAccepted-AOC 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹37.3 L+₹1.4 L (3.94%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹37.5 L+₹1.6 L (4.55%)Rejected-Finance | L-3 | Rejected-Finance L-3 |
Tender Value
₹37 L
EMD Value
₹37,000
Closing Date
24 Apr 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE
400KV S/S Sarnath Varanasi
Adding additional 1No. 132/33KV 40MVA T/F and its bay along with extension of 132KV Main Bus Bar at 132KV S/S Saidpur Under ETD-Ghazipur
2023_UPTCL_771828_3
E-Tender No. 20 ETC-II(VNS)/2022-23
Open Tender
Supply, Erection and Commissioning
Piece-work
120 days
Ghazipur
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,366
EE ETD Ghazipur
₹37,000
19 Jun 2023
17 Apr 2023
24 Apr 2023
17 Apr 2023
24 Apr 2023
17 Apr 2023
Amount
Part- A, Supply
Single tention fitting suitable for ACSR Moose
Single tention fitting suitable for ACSR Panther
Single Suspension fitting suitable for ACSR Panther
Single Suspension fitting suitable for ACSR Moose
PG Clamp Suitable for Panther to Panther
PG Clamp Suitable for Moose to Moose
PG Clamp Suitable for Moose to Panther
Bus post clamp Suitable for Twin Panther
Bus post clamp Suitable for Moose
70 KN antifog disc insulator
33 KV HT Power cable (XLPE type ) along with all accessories and termination joint
Portable AFF mechanical foam type fire Extinguisher complete with initial charge hose pipe and all other accessories and fitting as per IS 1024 trolley /Wheel mounted 45/50 liter capacity
Fire extinguisher carbon dioxide as per IS specn No 2878/1986 and as per technical specification
40 mm MS Rod for main earthmat
Part -B, Work (Erection of 40 MVA T/F)
Shifting upto 20 M of main tank of 40 MVA ,132/33 KV transformer from unloading place to plinth including turning of tank, if required. All T&P and all other associated works fo completion of job satisfactory.
Additinal shifting of 5 meter a part ther of 110 meter of 40 MVA 132/33 KV Transfomeer @5 meter per job.
Complete erection of 40 MVA, 132/33 KV Transformer by erection of radiators, conservator tank, all bushing, their turrets connecting all pipe lines, cooling fans, motor drive mechanism of tap charger, RTCC panels, oil pumps and associated oil pipe lines etc to complete the job satisfactorily including first filling of oil and topping up of T/F oil (Not circulation) in tank radiators, oil pipe lines, conservator tank etc, and attending the oil leakage, if any and all other associated works for satisfactory completion of job. Crane and T&P shall be provided by the contractor
Centrifusing of fresh transformer oil and filling of balance oil into the transformer with machine ,operator and to provide final BDV & PPM testing results. Machine and operator will be provided by the contractor.
Laying of following size control cable in the cable trench from control relay/ RTCC panel to Transformer marshalling/ Drive Mechanism as per cable schedule, its Saddling as every 75 mm distance with MS saddles of size of size 25x3mm , including carriage of cable drums from store to laying site and all other associated work to complete the job satisfactory.
2C x 2.5 sq.mm
4C x 2.5 sq.mm
6C x 2.5 sq.mm
10C x 2.5 sq.mm
Termination of different size (10x2.5mm², 06x2.5 mm², 4x2.5mm² and 2x2.5mm²) of above lead control cable.
2C x 2.5 sq.mm
4C x 2.5 sq.mm
6C x 2.5 sq.mm
10C x 2.5 sq.mm
Construction of Delta earthing by piercing 3 meter long electrodes in earth and then connecting them with each other by 75x10 mm M.S flat and connecting to neutal bushing ,the same with main earthmate at 2 places as required, excluding the cost of M.S. Bar and M.S. flat to be provided by the department free of cost. and all other associated work to completion the job satisfactory.
Earthing of 40 MVA, 132/33 KV Transformer including MB, OLTC, RTCC etc with M.S. flat to be provided by the Contractor with 50x6 mm and 75x10 mm M.S. flat and connecting the same with main earthmat at two places as required including painting of M.S. strip of one coat red oxide primer and two coat green enamel colour above ground surface. and all other associated work to completion the job satisfactory.
Part -C, Work (Erection of 40 MVA T/F Bay)
Collection , loading and carriage of subsation structure (15MT) from EFU NAINI Pryagraj to 132 KV S/S Saidpur and after carriage unloading it at 132 KV S/S Saidpur.
Loding of S/S Structure (15 MT) at EFU Naini .
Carriage of S/S Structure(15 MT ) from EFU Naini to 132 KV S/SSaidpur (Approx distance 200 KM) .
Unloading of S/S Structure (15 MT) at 132KV S/S Saidpur.
Erection of Main and auxiliary structure by shifting of structure from store to work site as per relevant drawing and practices using Nut - Bolt and spring washers .The material shall be supplied by department free of cost but the contractor has to manage T & P and all other associated work to complete the job satisfactory.
Stringing of 33 KV Main Bus Bar (R.Y& B Phase) with ACSR single Moose conductor including cutting, bending and clamping fitting of tension clamp with all associated accessories. Hoisting of insulator string after shifting of material from store to switchyard at site and all other associated work to complete the work satisfactory. The Bus will be of 36 Mtr. and section will be connected with clamp and jumper. The work also include the connection of this bnus with existing 33 KV Bus.
Stringing of 132 KV Jack Bus bar ( R, Y & B phase ) with ACSR single Panther conductor including cutting, bending and clamping fitting of tension clamp with all associated accessories, hoisting of insulator string after shifting of material from store to work site and all other associated work to complete the work satisfactory.
Stringing of 132 KV Main Bus bar of all three phases ( R, Y & B phase ) with ACSR single Moose conductor including cutting, bending and clamping fitting of tension clamp with all associated accessories, hoisting of insulator string after shifting of material from store to work site and all other associated work to complete the work satisfactory.
Erection of following equipments as per instruction manual of various equipments and technical specification including shifting of material from store to work site includig all other associated work to complete the job Satisfactory.
145 KV BSI
145 KV SF6 ,CB
Junction box for 145 KV CT
Junction box for 145 KV LSI & BSI
Junction box for 36 KV CT
36 KV VCB
36 KV BSI
Junction box for 36 KV BSI
Rely&control panel for 40 MVA Power Tranformer.
Erection of ABT Energy Metering panel with main and check rack complete in all respect.
Jumpering of transformer and associated equipments using single/double panther/zebra/moose conductor from bus bar to isolators,CB,CT,LA, etc on both sides required.
Laying of follwing size control cables from control & relay panels to various equipment junction boxes etc in switchyard as per cable schedule, its binding at every 1.5 mtr. distance with M.S. saddle including carriage of cable from store to work site and shiftingback to store and all associated works to complete the job satisfactorily .
2C x 2.5 sq. mm
4C x 2.5 sq. mm
6C x 2.5 sq. mm
10C x 2.5 sq. mm
Termination of above cable as per cable schedule including making necessary holes in gland plates of boxes where ever required including Supply and fixing of cable glands of approxinmate size and to provide ferrules and nos. for each core of cable and its termination with all the other associated works to complete the Job.
2C x 2.5 sq. mm
4C x 2.5 sq. mm
6C x 2.5 sq. mm
10C x 2.5 sq. mm
Delta earthing of 120 KV LA consisting of 03 Nos 3 meter long electodes its placing inside the ground and connecting all three electrodes with 75x10 mm MS flat and connecting the same with LA at two place required including cost of M.S strip excluding cost of M.S round bar.
Earthing of Main & Auxiliary structure and various type equipments (CT, PT, CB, LA, LSI, BSI etc ) by M.S strips by cutting to proper size, digging of earth from ground level to earthmat then proper welding as per drawing and leveling earth. Painting of M.S Strips of one coat red oxide primer and two coat with green colour and all associated work to complete the job satisfactory . M.S Flat will be provided by the contractor.
Laying of 40 mm dia. Round bar 700 mm below ground level includind cutting tightening welding painting excavation of trench by back filling and all other associeted work to complete the work satisfactory as per technical specification excluding cost of 40 mm dia. round bar.
Laying of 33KV, 3X300 sqmm HT Power XLPLE cable & jointing of outdoor cable by jointing kit at both sides (08 No). The work also includes make proper look at both sides by digging of earth and filled with sand and other associated work complete the job satisfactory .
Fabrication of 3 meter long electrode with 40 mm MS round bar having 150 mm conical shape and then its piercing vertically inside the ground with top 700 mm below ground level and its welding exluding cost of 40 mm dia. Round bar
M/s S.S. Refregeration
Meena Elect & Engg. Works
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .