Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | ₹20.4 L Quoted ₹22.0 L | L1 | Accepted-AOC lowest |
| 2 | L2₹24.7 L+₹2.7 L (12.2%)Rejected-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹24.7 L+₹2.7 L (12.2%) | L2 | Rejected-Finance other than lowest |
| Sl No | Description | Qty | Unit | SUN MANN ENGINEERS L2 | CHOUDHARY ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00Sch 'A' | |||||
| 1.01 | Excavation in trenches in soft/loose of soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for taking out of unserviceable under ground cable complete all as specified and directed. | 310.5 | Cum | 65 ₹20,182.5 Lowest | 160 ₹49,680 |
| 2.00 | Returning, filling in, any type of soil and spreading in layers not exceeding 25 cm thick complete all as specified and directed. | 195.6 | Cum | 20 ₹3,912 Lowest | 44 ₹8,606.4 |
| 3.00 | Removal of surplus soil (any type of soil obtained from excavation) to a distance not exceeding 50 metre and depositing where directed complete all as specified and directed. | 114.9 | Cum | 20 ₹2,298 Lowest | 188 ₹21,601.2 |
| 4.00 | Supplying and laying bricks common brunt clay building bricks sub class 'B' including removing of old bricks complete all as specified and directed. | 6.9 | Nos/ 1000 | 4,000 ₹27,600 | 3,800 ₹26,220 Lowest |
| 5.00 | Material and labour for sand cushioing with a layer of fine sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. Notes-:(i) Excavation and earth work to be measured and paid for separately.(ii)Thickness of 18cms after punning shall be considered for payment. | 93.15 | Cum | 280 ₹26,082 Lowest | 600 ₹55,890 |
| 6.00 | M&L in replacement for cross arms, bracings, supports clamps and back plate fabricated from steel structural including nuts,bolts washers welding,bending cold or hot,drilling holes and inclusive of one primer coat, one under coat and one finishing coat of paint including dismantling of existing unserviceable cross arms of any description and in any position complete all as specified and directed. | 0.3 | Qtl | 7,500 ₹2,250 Lowest | 12,000 ₹3,600 |
| 7.00 | M&L for loop type insulator, porcelain vitreous white or brown, with overall dimensions of 65mm x 90mm, clearance of hole 16mm including dismantling of existing unserviceable Insulators of any description and in any position including dismantling of existing unserviceable Insulators of same type complete all as specified and directed. | 4 | Each | 50 ₹200 Lowest | 170 ₹680 |
| 8.00 | M& L for pin type porcelain vitreous, white, brown or green insulators including one galvanized mild steel spindle two galvanized iron washers and one galvanised iron nuts and 65 mm dia , 100mm height for 1100 volt grade including dismantling of existing unserviceable Insulators of same type complete all as specified and directed. | 4 | Each | 50 ₹200 Lowest | 200 ₹800 |
| 9.00 | M&L shackle type, porcelain, vitreous, white, brown or green insulator incl galvanised mild steel straps, washers, insulators bolts, washers and nuts complete 100 mm height and 115 mm dia for 1100 volts including dismantling of existing unserviceable Insulators of same type complete all as specified and directed. | 4 | Each | 50 ₹200 Lowest | 210 ₹840 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
23 Oct 2025, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana-141001 (Punjab)
Repair/Comprehensive maint to LT electric supply, Panels, capacitor bank and allied E/M works at Baddowal and Moga under GE Ludhiana
2025_MES_731529_1
GE/LDH-48/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Baddowal and Moga
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹50,000
Yes
13 Dec 2025
18 Sept 2025
25 Oct 2025
18 Sept 2025
23 Oct 2025
10 Oct 2025
18 Sept 2025 - 9 Oct 2025
Amount
Excavation in trenches in soft/loose of soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for taking out of unserviceable under ground cable complete all as specified and directed.
Returning, filling in, any type of soil and spreading in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of surplus soil (any type of soil obtained from excavation) to a distance not exceeding 50 metre and depositing where directed complete all as specified and directed.
Supplying and laying bricks common brunt clay building bricks sub class 'B' including removing of old bricks complete all as specified and directed.
Material and labour for sand cushioing with a layer of fine sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. Notes-:(i) Excavation and earth work to be measured and paid for separately.(ii)Thickness of 18cms after punning shall be considered for payment.
M&L in replacement for cross arms, bracings, supports clamps and back plate fabricated from steel structural including nuts,bolts washers welding,bending cold or hot,drilling holes and inclusive of one primer coat, one under coat and one finishing coat of paint including dismantling of existing unserviceable cross arms of any description and in any position complete all as specified and directed.
M&L for loop type insulator, porcelain vitreous white or brown, with overall dimensions of 65mm x 90mm, clearance of hole 16mm including dismantling of existing unserviceable Insulators of any description and in any position including dismantling of existing unserviceable Insulators of same type complete all as specified and directed.
M& L for pin type porcelain vitreous, white, brown or green insulators including one galvanized mild steel spindle two galvanized iron washers and one galvanised iron nuts and 65 mm dia , 100mm height for 1100 volt grade including dismantling of existing unserviceable Insulators of same type complete all as specified and directed.
M&L shackle type, porcelain, vitreous, white, brown or green insulator incl galvanised mild steel straps, washers, insulators bolts, washers and nuts complete 100 mm height and 115 mm dia for 1100 volts including dismantling of existing unserviceable Insulators of same type complete all as specified and directed.
S&F in replacement ACSR conductor steel, reinforced on over head lines fixed on insulators, binding with and including binding wire 14 swg including dismantling & taking down of existing worn out/unserviceable aluminium conductor, steel reinforced (ACSR) of any description /size & in any position from existing LT pole/ Lines complete all as specified and directed. ( Note : For payment purposes, the weight of binding wire shall not be consider.)
Supplying and drawing and fixing in replacement of continous GI earth wire/guard cradles 4 mm dia including GI binding wire 1.63mm on LT poles including dismantling & taking down of existing worn out / unserviceable GI wire of any description /size & in any position from existing LT Lines including cradle guard/ earth continuty wires complete all as specified and directed.
M&L in replacement stay assembly comprising of GI stay bow 14 mm dia, 40 cm long (over all) galvanised stay rod 16 mm dia 215 cm long with threaded ends GI nuts, bolts, washers, stay plate 30 cm x 30 cm x 6 mm thick 2 Nos of thimbles, MS clamps made out of 50 mm x 6 mm flat iron complete including stay wire 7/8 SWG complete all assprcified and directed including necessary excavation and earth work and PCC 1:3:6 all as shown in electrical plate No.1 of SSR-1991 Part-I (PCC and earth work, loop type insulator, stay clamps shall be measured and paid for separately under the respective item of schedule) including taking down existing old unsv stay assembly dismantling of existing unserviceable stay assembly of any size and in any position complete all as specified and directed.
M & L for danger notice plates made out of 1.6mm thick mild steel sheet, vitreous enamelled white letters, figures, and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size including taking down existing old unsv danger notice plate complete all as specified and directed.
Supply, laying, jointing, testing and commissioning in replacement of cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, fixed by means of MS saddles on or fixed on poles including connection with proper lugs for the following size including taking out old one complete all as specified and directed.
95 Sqmm 3.5 Core
120 Sqmm 3.5 Core
185 Sqmm 3.5 Core
400 Sqmm 3.5 Core
Supply and fix of Aluminium Lugs suitable for 16 to 35 Sqmm 1100 Volts including taking down old unserviceable lugs complete all as specified and directed.
Supply and fix of aluminium Lugs suitable for 70 to 120 Sqmm 1100 Volts including taking down old unserviceable lugs complete all as specified and directed.
Supply and fix of Aluminium Lugs suitable for 185 to 400 Sqmm 1100 Volts including taking down old unserviceable lugs complete all as specified and directed.
Supply and fixing in replacment GI pipe light grade 40 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah including taking up old GI pipe complete all as specified and directed.
All as per Ser item No 18 here-in-before but size 50 mm dia complete all as specified and directed.
All as per Ser item No 18 here-in-before but size 80 mm dia complete all as specified and directed.
Supply and fixing in replacement of MCCB of current rating 400 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity (Ics=100% Icu) with adjustable thermal and adjustable magnetic type release including taking down old unserviceable MCCBs complete all as specified and directed.
Supply and fixing in replacement of MCCB of current rating 250 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity(Ics=100% Icu) with adjustable thermal and adjustable magnetic type release including taking down old unserviceable MCCBs complete all as specified and directed.
Supply and fixing in replacement of MCCB of current rating 125 Amps, 4 pole, 415 volts AC, 16 KA rupturing capacity (Ics=100% Icu) with adjustable thermal and adjustable magnetic type release including taking down old unserviceable MCCBs complete all as specified and directed.
Supply and fixing in replacement of MCCB of current rating 100 Amps, 4 pole, 415 volts AC, 16 KA rupturing capacity (Ics=100% Icu) with adjustable thermal and adjustable magnetic type release including taking down old unserviceable MCCBs complete all as specified and directed.
Supply and fixing in replacement of PVC two wire separator for LT lines including taking out old unserviceable seperator complete all as specified and directed.
Supply and fixing in replacement of PVC four wire separator for LT lines including taking out old unserviceable seperator complete all as specified and directed.
Supply and fixing in replacement digital voltmeter (0-500 Volts) 96x96mm square type including taking out old unserviceable voltmeter complete all as specified and directed.
Supply and fixing in replacement digital Amps meter (0-600 Amp) 96x96mm square type including taking out old unserviceable seperator complete all as specified and directed.
Material and labour for replacement of indicator lamp in red, yellow and blue colour with lamp holder multi LED type complete including wiring with copper conductor cable of suitable size complete all as specified and directed.
M&L for painting of panel board of inner & outer complete with synthetic enamel paint colours siemens grey by spraying including filling cavaties with filler one coat after cleaning all dust/rust including writing the Distribution/Panel Number and panel details complete all as specified and directed. Note: The Quoted rates are inclusive of white wash to fountation of Panel Board/ Painting to Angle Frames complete .
S&F for jointing and testing LT straight through (heat shrinkable) joint suitable for LT cable 1100 volts grade 25 Sqmm to 35 Sqmm complete all as specified and directed.
S&F for jointing and testing LT straight through (heat shrinkable) joint suitable for LT cable 1100 volts grade 70 Sqmm complete all as specified and directed.
S&F for jointing and testing LT straight through (heat shrinkable) joint suitable for LT cable 1100 volts grade 95 Sqmm complete all as specified and directed.
S&F for jointing and testing LT straight through (heat shrinkable) joint suitable for LT cable 1100 volts grade 120 Sqmm to 150 Sqmm complete all as specified and directed.
S&F for jointing and testing LT straight through (heat shrinkable) joint suitable for LT cable 1100 volts grade 185 Sqmm complete all as specified and directed.
S&F for jointing and testing LT straight through (heat shrinkable) joint suitable for LT cable 1100 volts grade 240 Sqmm complete all as specified and directed.
S&F for jointing and testing LT straight through (heat shrinkable) joint suitable for LT cable 1100 volts grade 400 Sqmm complete all as specified and directed.
Supply & fixing in replacement power factor controller relay latest micro controller based tech with true RMS sensing alarm avilable , delay adjustment , LCD display range 08 steps , 7 segment LED display size 144 X 144mm Auxillary supply 90-550 VAC, NTC tempature sensor , power factor measurement range 0.8 lag to 0.8 le suitable for APFC Panel complete all as specified and directed.
Supply & fixing in replacement power factor controller relay latest micro controller based tech with true RMS sensing alarm avilable , delay adjustment , LCD display range 12 steps , 7 segment LED display size 144 X 144mm Auxillary supply 90-550 VAC, NTC tempature sensor , power factor measurement range 0.8 lag to 0.8 le suitable for APFC Panel complete all as specified and directed.
Supply & fixing in replacement heavy duty cylindrical capacitor 5 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel including taking down old capacitor same capacity complete all as specified and directed.
Supply & fixing in replacement heavy duty cylindrical capacitor 10 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel including taking down old capacitor same capacity complete all as specified and directed.
Supply & fixing in replacement heavy duty cylindrical capacitor 15 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel including taking down old capacitor same capacity complete all as specified and directed.
Supply & fixing heavy duty cylindrical capacitor 20 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel including taking down old capacitor same capacity complete all as specified and directed.
Supply & fixing heavy duty cylindrical capacitor 25 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel including taking down old capacitor same capacity complete all as specified and directed.
Supply & fixing in replacement current transformer CT 400/5A CL 1 5VA Spare suitable for APFC Panel including taking down current transformers CT same capacity complete all as specified and directed.
Supply & fixing in replacement current transformer CT 160/5A CL 1 5VA Spare suitable for APFC Panel including taking down current transformers CT same capacity complete all as specified and directed.
Supply & fixing in replacement current transformer CT 100/5A CL 1 5VA Spare suitable for APFC Panel including taking down current transformers CT same capacity complete all as specified and directed.
Tree pruning near overhead LT lines (tools and allied items required for tree pruning will be provided by the contractor) complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technique and necessary T&P for passing of LT/HT cables complete all as specified and directed.
Taking out existing LT cable and relaying the same after removal of cable fault including jointing,testing and commissioning complete all as specified and directed. NOTES : (i) Excavation & earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be measured and paid separately.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
S&F in replacement of heat shrinkable sleeves of different colours complete all as specified and directed.
Supply installng, testing and commissioning floor mounted LT panel indoor type (CPRI approved) of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3 mm thick and angle iron frame of 50x50x6mm and 04 Nos legs on angle iron 50x50x6mm each 600mm long panel duly powder coated having insulated bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles,with cable gland and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate Powder Coated Spray painted from outside and inside with approved stove enameled siemens grey paint two coats over one coat of red oxide primer including taking out oldunserviceable panel complete as under :- A.Incomer Feeder - (i) ACB 630 Amps 4 pole 50 KA Microprocessor release MDO - 01 Nos. (ii) Shunt Release - 01 Nos. (iii) UV Shunt - 01 Nos. (iv) Digital Volt Meter 3 Phase - 01 Nos. (v) Digital Amp Meter 3 Phase - 01 Nos. (vi) Indicator Red,Yellow - 02 Nos. (vii) Indicator Blue - 01 Nos. (viii) CT Coil 630/5 Amp - 03 Nos. (ix) On Load Change over 200 Amp 4 Pole - 01 Nos. (x) Control MCB SP 6 Amp 10 KA - 03 Nos. B.Outgoing Feeder - (i) MCCB 315 Amps 4 pole 36 KA adjustable thermal and adjustable magnetic - 03 Nos.(ii) Spreader link 315 Amp 4 pole - 03 Nos. (iii) MCCB 200 Amp 4 Pole 25 KA fixed thermal and fixed magnetic - 01 Nos. (iv) Spreader link 200 Amp 4 pole - 01 Nos. (v) MCB TPN 63 Amp 10 KA - 01 Nos. (vi) MCB SPN 40 Amp 10 KA - 02 Nos. C.Main Bus Bar - Aluminium busbar 630 Amp TPN - 04 Nos.
Supply installng, testing and commissioning floor mounted LT panel indoor type (CPRI approved) of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3 mm thick and angle iron frame of 40x40x6mm and 04 Nos legs on angle iron 50x50x6mm each 600mm long panel duly powder cocted having insulated bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles,with cable gland and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate Powder Coated Spray painted from outside and inside with approved stove enameled siemens grey paint two coats over one coat of red oxide primer including taking out oldunserviceable panel complete as under :- A.Incomer Feeder - (i) ACB 630 Amp 4 pole 50 KA Microprocessor release MDO - 01 Nos. (ii) Shunt Release - 01 Nos. (iii) UV Shunt - 01 Nos. (iv) Digital Volt Meter 3 Phase - 01 Nos. (v) Digital Amp Meter 3 Phase - 01 Nos. (vi) Indicator Red,Yellow - 02 Nos. (vii) Indicator Blue - 01 Nos. (viii) CT Coil 630/5 Amp - 03 Nos. (ix) Control MCB SP 6 Amp 10 KA - 03 Nos. B.Outgoing Feeder - (i) MCCB 315 Amps 4 pole 36 KA adjustable thermal and adjustable magnetic - 03 Nos.(ii) Spreader link 315 Amp 4 pole - 03 Nos. (iii) MCCB 100 Amp 4 Pole 25 KA fixed thermal and fixed magnetic - 01 Nos. (iv) Spreader link 100 Amp 4 pole - 01 Nos. (v) MCB TPN 63 Amp 10 KA - 01 Nos. (vi) MCB SPN 40 Amp 10 KA - 02 Nos. C.Main Bus Bar - Aluminium busbar 630 Amp TPN - 04 Nos.
Supply installng, testing and commissioning floor mounted LT panel indoor type (CPRI approved) of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3 mm thick and angle iron frame of 40x40x6mm and 04 Nos legs on angle iron 50x50x6mm each 600mm long panel duly powder coacted heaving insulated bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles,with cable gland and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate Powder Coated Spray painted from outside and inside with approved stove enameled siemens grey paint two coats over one coat of red oxide primer including taking out oldunserviceable panel complete as under :- A.Incomer Feeder - (i) MCCB 400 Amp 4 pole 36 KA fixed thermal and fixed magnetic - 01 Nos. (ii) Spreader link 400 Amp 4 pole - 01 Nos. (iii) Digital Volt Meter 3 Phase - 01 Nos. (iv) Digital Amp Meter 3 Phase - 01 Nos. (v) Indicator Red,Yellow - 02 Nos. (vi) Indicator Blue - 01 Nos. (vii) CT Coil 630/5 Amp - 03 Nos. (viii) Control MCB SP 6 Amp 10 KA - 03 Nos. B.Outgoing Feeder - (i) MCCB 250 Amp 4 pole 36 KA adjustable thermal and adjustable magnetic - 01 Nos.(ii) Spreader link 250 Amp 4 pole - 01 Nos. (iii) MCCB 200 Amp 4 Pole 25 KA fixed thermal and fixed magnetic - 01 Nos. (iv) Spreader link 200 Amp 4 pole - 01 Nos. (v) MCCB 100 Amp 4 Pole 25 KA fixed thermal and fixed magnetic - 01 Nos. (vi) Spreader link 100 Amp 4 pole - 01 Nos. (vii) MCB TPN 63 Amp 10 KA - 01 Nos. (viii) MCB SPN 40 Amp 10 KA - 02 Nos. C.Main Bus Bar - Aluminium busbar 400 Amp TPN - 04 Nos.
Supply installng, testing and commissioning floor mounted LT panel indoor type (CPRI approved) of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3 mm thick and angle iron frame of 40x40x6mm and 04 Nos legs on angle iron 50x50x6mm each 600mm long panel duly powder coacted heaving insulated bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles,with cable gland and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate Powder Coated Spray painted from outside and inside with approved stove enameled siemens grey paint two coats over one coat of red oxide primer including taking out oldunserviceable panel complete as under :- A.Incomer Feeder - (i) ACB 630 Amp 4 pole 50 KA Microprocessor release MDO - 01 Nos. (ii) Shunt Release - 01 Nos. (iii) UV Shunt - 01 Nos. (iv) Digital Volt Meter 3 Phase - 01 Nos. (v) Digital Amp Meter 3 Phase - 01 Nos. (vi) Indicator Red,Yellow - 02 Nos. (vii) Indicator Blue - 01 Nos. (viii) CT Coil 630/5 Amp - 03 Nos. (ix) Control MCB SP 6 Amp 10 KA - 03 Nos. B.Outgoing Feeder - (i) MCCB 400 Amp 4 pole 36 KA adjustable thermal and adjustable magnetic - 01 Nos.(ii) Spreader link 400 Amp 4 pole - 01 Nos. (iii) MCCB 250 Amp 4 Pole 25 KA fixed thermal and fixed magnetic - 03 Nos. (iv) Spreader link 250 Amp 4 pole - 03 Nos. (v) MCCB 100 Amp 4 Pole 25 KA fixed thermal and fixed magnetic - 01 Nos. (vi) Spreader link 100 Amp 4 pole - 01 Nos. (vii) MCB TPN 63 Amp 10 KA - 01 Nos. (viii) MCB SPN 40 Amp 10 KA - 02 Nos. C.Main Bus Bar - Aluminium busbar 630 Amp TPN - 04 Nos.
SUN MANN ENGINEERS (BID ID -3457424)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Tende48202526.pdf
Tender Documents • 0.68 MB
BOQ_819003.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .