Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.3 LAccepted-AOC | L1 | Accepted-AOC After deduction of Sch of credit Rs. 2,31,039.50 | |
| 2 | L2₹73.8 L+₹13.2 L (21.7%)Rejected-Finance PITHORAGARH PIN 900 336 C O 56 APO | 900336 | L2 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | AJA BUILDERS L1 | Mahamaya Engineers Services L2 |
|---|---|---|---|---|---|
| 1.00 | Dismantling of Steel poles including demolition of coping and levelling of ground and making surface dressing as required or as per direction of Engr-in-Charge. | 3 | Each | 400 ₹1,200 Lowest | 1,000 ₹3,000 |
| 2.00 | Dismantling of cross arms/bracings of MS Sections channel or angle sections etc., complete all as specified and as per direction of Engr-in-Charge. | 1 | Per Qtl | 100 ₹100 Lowest | 200 ₹200 |
| 3.00 | Dismantling of insulators any type, any size as required and as per direction of Engr-in-Charge. | 18 | Each | 10 ₹180 Lowest | 10 ₹180 Lowest |
| 4.00 | Dismantling/Taking Down old U/S lightning arresters any size as required and as per direction of Engr-in-Charge. | 3 | Each | 100 ₹300 | 10 ₹30 Lowest |
| 5.00 | Dismantling/Taking Down old U/S GI wire 4 mm dia on HT electric lines including binding, jointing and for guarding cradle or distributor span as per direction of Engr-in-Charge. | 1.5 | Qtl | 100 ₹150 Lowest | 100 ₹150 Lowest |
| 6.00 | Supply, fixing, transporting, erecting and fixing steel tubular swaged pole type 410 SP- 31 (11 metres long) complete with cast iron base plate, finial taper plug MS bolts, and washers including two coats of aluminium paint over a coat of red oxide primer to external surfaces of steel tubular pole and two coats of anti-corrosive bituminous paint internally and externally up to planting depth of pole and providing 3 bands/ straps with paint red post office colour and 2 bands with black synthetic enamel paint 300mm from plinth block and marking pole No. with black synthetic enamel paint and feeder location of Pole including dismantling of existing damaged steel pole/struts etc complete all as specified and directed. | 3 | Each | 21,000 ₹63,000 Lowest | 25,000 ₹75,000 |
| 7.00 | M&L for mild steel work Fe-410-S grade in cross arms, bracing, support, clamps and back plate, fabricated from structural steel section including nuts bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including two coats of aluminium paint over a coat of red oxide primer including dismantling cross arms of mild steel channel or angle section etc complete all as specified and directed. | 1 | Per Qtl | 10,000 ₹10,000 Lowest | 13,000 ₹13,000 |
| 8.00 | Supply and fixing pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and directed by Engr-in-charge. | 6 | Each | 350 ₹2,100 | 250 ₹1,500 Lowest |
| 9.00 | Supply and fixing shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts in repair insulators suitable for working pressure in 11000 volts of height 150mm and max dia 150mm along with galvanised steel fittings section of straps in 38x5mm and dis of bolts 20mm complete all as specified and directed by Engr-in-charge. | 6 | Each | 450 ₹2,700 | 250 ₹1,500 Lowest |
| 10.00 | M&L in repair of disc type insulator porcelain vitreous 145mm high and 255mm dia ball and socket type white brown or green single disc assembly for tension with tension clamps for conductors working pressure 11000 volts complete all as specified and directed by Engr-in-Charge. | 6 | Each | 750 ₹4,500 | 500 ₹3,000 Lowest |
Tender Value
₹76.1 L
EMD Value
₹1.4 L
Closing Date
11 Oct 2025, 6:00 pmClosed
CWE (HILLS) PITHORAGARH
HQ CWE (HILLS) PITHORAGARH POST OFFICE - BHARKATIA DISTRICT - PITHORAGARH STATE - UTTARAKHAND PIN 262520
CA NO. CWE/HILLS/RKT/59 OF 2025-2026 REPAIR/REPLACEMENT OF STREET LIGHT FITTING, MCCB, LT OVER HEAD/ UNDER GROUND LINE INCL EXTERNAL WATER SUPPLY FITTING AND PIPE LINE AND REPAIR TO HT OVERHEAD VCB, ACB, GOD ETC. AT HALDWANI, RANIBAGH AND KATHGODAM A
2025_MES_729779_1
89248/25-26/E8
Open Tender
Civil Works
Item Rate
180 days
HALDWANI
Class - C
9 documents required · 9 mandatory
₹1,000
GE (MES) RANIKHET
₹1.4 L
Yes
3 Dec 2025
8 Sept 2025
18 Oct 2025
8 Sept 2025
11 Oct 2025
22 Sept 2025
Amount
Dismantling of Steel poles including demolition of coping and levelling of ground and making surface dressing as required or as per direction of Engr-in-Charge.
Dismantling of cross arms/bracings of MS Sections channel or angle sections etc., complete all as specified and as per direction of Engr-in-Charge.
Dismantling of insulators any type, any size as required and as per direction of Engr-in-Charge.
Dismantling/Taking Down old U/S lightning arresters any size as required and as per direction of Engr-in-Charge.
Dismantling/Taking Down old U/S GI wire 4 mm dia on HT electric lines including binding, jointing and for guarding cradle or distributor span as per direction of Engr-in-Charge.
Supply, fixing, transporting, erecting and fixing steel tubular swaged pole type 410 SP- 31 (11 metres long) complete with cast iron base plate, finial taper plug MS bolts, and washers including two coats of aluminium paint over a coat of red oxide primer to external surfaces of steel tubular pole and two coats of anti-corrosive bituminous paint internally and externally up to planting depth of pole and providing 3 bands/ straps with paint red post office colour and 2 bands with black synthetic enamel paint 300mm from plinth block and marking pole No. with black synthetic enamel paint and feeder location of Pole including dismantling of existing damaged steel pole/struts etc complete all as specified and directed.
M&L for mild steel work Fe-410-S grade in cross arms, bracing, support, clamps and back plate, fabricated from structural steel section including nuts bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including two coats of aluminium paint over a coat of red oxide primer including dismantling cross arms of mild steel channel or angle section etc complete all as specified and directed.
Supply and fixing pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and directed by Engr-in-charge.
Supply and fixing shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts in repair insulators suitable for working pressure in 11000 volts of height 150mm and max dia 150mm along with galvanised steel fittings section of straps in 38x5mm and dis of bolts 20mm complete all as specified and directed by Engr-in-charge.
M&L in repair of disc type insulator porcelain vitreous 145mm high and 255mm dia ball and socket type white brown or green single disc assembly for tension with tension clamps for conductors working pressure 11000 volts complete all as specified and directed by Engr-in-Charge.
M&L for stringing, drawing of GI wire 4 mm dia on HT electric lines including binding, jointing and for guarding cradle made to shape hexagonal/rectangular or any shape fabricated etc complete all as specified and directed.
M&L in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white with letter figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 25x20cm size etc complete all as specified and directed.
M&L for lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo amp, HT 11000 Volts grade complete all as specified and directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as specified and directed.
All as per item No. 14 here in before, but 120 sqmm to 185 sqmm.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as specified and directed.
All as per item No. 16 here in before, but 120 sqmm to 185 sqmm.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as specified and directed.
All as per item No. 18 here in before, but 120 sqmm to 185 sqmm.
Supply, laying, connecting, testing and commissioning of 120 Sqmm 3 core earthed system underground HT XLPE insulated screened, PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor 11000 Volts laid in trenches, fixed to walls/ drawn through pipe with suitable size glands, crimping type lugs and including the disturbed surface of road making good with using PCC etc all as specified including dismantling of old U/S cable. Note;-(Excavation, earthwork send cushioning and cable protection shall be measured and paid for separately.)
All as per item No. 20 here in before, but cable size 95 Sqmm, 3 core
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 KV for electrical purpose as per IS 15652-2006, (Superseding IS 5424) suitable for electrical shock safety of size 2m x 1 m complete all as specified and directed.
M&L for Earthing complete with copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as buried directly in ground (earth pit not less than 2. 25mtr deep below ground level) with top edge of plat not less than 1.5 mtr below normal ground level connected to copper earth strip 20×3mm as earthing lead by means of bolts, nuts , check nuts and washers of copper or Brass all as shown in electrical plate No 2 and including excavation and earth work, GI pipe light grade 40 mm bore for protection of copper earth strip from earth electrode to and including the earth test point of galvanized Iron/steel of size 75x75x 25mm, supplying and laying charcoal dust, common salt for Earthing, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia TMT bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh,40 mm dia GI pipe light grade for watering and connected to earth test point including brazing at all joints except at test point and testing complete all as specified and directed by Engr-in-Charge.
M&L for Earthing complete with galvanized sheet earth plate electrodes 60x60x6.3 mm thick buried directly in ground (earth pit not less than 2. 25mtr deep below ground level) with top edge of plat not less than 1.5 mtr below normal ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts , check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to and including the earth test point of galvanized Iron/steel of size 75x75x 25mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia TMT bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh,20 mm dia GI pipe light grade for watering and connected to earth test point including brazing at all joints except at test point and testing complete all as specified and directed by Engr-in-Charge.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide, depth exceeding 1.5 mtr and getting out in hard/dense soil complete all as specified and directed by Engineer-in-charge
Returning, filling including spreading, levelling, watering and well ramming in layers not exc. 25 cm in hard/dense soil all as specified and directed.
Removing excavated material (soil) not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for dry clean sand filling in trenches below and around underground cable cushioning complete all as specified and directed. Note: - Thickness of sand cushioning shall be measured after punning.
Supplying and laying un-reinforced precast concrete cable cover class HV type 1 flat size 300x180mmx40mm complete all as specified and directed.
M&L in repair to burnt transformer upto capacity 630 KVA indoor/outdoor type 11 KV / 440 volts removing HT & LT cable connection from transformer and taking into the workshop with the help of man power, crane, truck, TPT etc opening the top cover lifting the core removing sludge with oil pressure pump, repair of burnt/damage winding of suitable size including core limb, insulating material, applying two coats of insulation paper/varnish etc and put in the oven for 24 hrs and cleaning the tank sludge etc. After completion of the job, transformer tests to be carried out that is no load test short circuit test and oil colour test to be done at factory in the presence of Engineer -in- charge. Any damages of bushes and studs to be replaced. Shifting the transformer from workshop to substation etc all as specified and directed. Note: - (i) Spare parts measured and paid separately. (ii) Standby transformer suitable KVA should be provided by contractor at the site for uninterrupted supply and the cost/rent of standby deemed to be including in repairing cost and no extra payment shall be made on this account.
Supply and fixing in repair HT busing 11 KV upto capacity 630 KVA
Supply and fixing in repair LT busing 11 KV upto capacity 630 KVA
Supply and fixing in repair HT brass studs 11 KV capacity 315 KVA to 630 KVA
Supply and fixing in repair HT brass studs 11 KV upto capacity 250 KVA
Supply and fixing in repair LT brass studs 11 KV capacity 315 KVA to 630 KVA
Supply and fixing in repair LT brass studs 11 KV upto capacity 250 KVA
Supply and fixing new breathers upto capacity 630 KVA
Supply, fixing and commissioning of copper winding wire of transformer complete removing job/core inside of body and refixing same after rewinding of burn winding complete all as specified and directed.
Dehydration and filtration of transformer oil of distribution transformer any capacity indoor/outdoor type at various location to achieve di-electric strength not less than 60KV with dehydration machine including checking of electric strength of transformer oil before and after dehydration all as specified and as directed.
Supply and topping up of transformer oil with die-electric strength not less than 60 KV in to conservator tank / Body tank of the transformer etc. complete all as specified and directed. Make- Power oil or equivalent.
Preventive maintenance of transformer 63 to 630 KVA indoor/outdoor type 11 KV / 440 volts following repairs complete all as specified and as directed. [a] Draining out transformer in the suitable capacity of container / drums and keeping it in safe custody for reuse. [b] Lifting, transporting & handling the transformer to the work shop and opening top cover of the transformer by unscrewing nuts / bolts / washers etc. including disconnecting core assembly from HT / LT bushing and lifting the same gently with the help of crane and taking out from the shell [Container / Body] of the transformer. [c] Visual inspection of entire Core Assembly, Transformer Tank, Core Limbs, OLTC etc., locating the fault / damages. [d] Cleaning the transformer body from inside, removing deposited dirt / sludge / foreign particles etc. from the bottom / body of the transformer, cleaning with CTC and drying up the shell from inside before refilling with the Transformer Oil. [e] Cleaning and washing thoroughly core and serviceable windings of the transformer by hosing down with clean dry oil conforming to IS – 336, removing deposited dirt / sludge / foreign particles from the windings / core through inspection of windings, providing insulations to leads and terminals complete and re-assembling the core including newly winded coils etc. [f] Heating / drying / baking complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc all as per IS. [g] Lifting and refixing core assembly inside the transformer shell gently and carefully connecting Primary / Secondary / Neutral Terminal Connections to the bushings assembly, fixing of Tap changer including tightening of nuts, bolts, washers of the core to reduce humming noise. [h] Refilling the filtered transformer oil in the shell of transformer complete. [i] Refixing the top cover including replacement of Cork Sheet / Gasket 8 mm thick tightening of nuts / bolts / washers etc. and replacement of Breather with Silica Gel. [j] Lifting / Shifting to the place from where removed and re-installing the transformer including connecting Primary / Secondary / Neutral connections etc. [k] The inspection of transformer shall involve Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts, checking all brazing, joints, tap heads and connection joints, checking all jumpers, terminations / connections inside the transformer and Checking the Bucholtz Relay / Conservator MOG if any. Note: - Standby transformer suitable KVA should be provided by contractor at the site for uninterrupted supply
M&L for complete servicing / calibration of Vaccum Circuit Breaker of capacity 630 KVA for carrying out following Repairs, Overhauling, Servicing, Preventive Maintenance and refixing the same after Repair / Overhauling complete and calibration to VCB with required instrument for all function of VCBs like over current (OC), Under Voltage (UV), Earth Fault (EF), instant tripping mechanism operationon fault and testing all as specified and as directed: [a] Tripping off the breaker, lowering the breaker with raising / lowering handle and pulling out the breaker complete from the panel along with the trolley for servicing / inspection / overhauling. [b] Servicing / Inspecting / checking of Automatic Safety Shutter operation for serviceability and replacement of spares if required. [c] Servicing / Inspecting / checking of circuit spout and circuit spout connections for RYB Phases and replacement of spares if required. [d] Dismantling and checking of Crossbar Assembly, fixed contacts and current carrying parts of the breaker, trolley, insulated assembly and checking lamination with clamps, epoxy spout, isolator assembly etc. [e] Setting, reassembling, cleaning, adjustment of fixed contacts, main contact, arcing contacts and chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism. [f] Servicing / Inspecting / checking of Secondary Sockets / Busbar Earthing Plugs / Earthing Sockets and replacement of spares if required. [g] Checking, setting and adjustment of lowering and raising operation of the Breaker Trolley. [h] Decarbonising of Busbar and connected items [i] Lubrication and greasing of all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear, isolation resistance of trolley of with vacuum interrupter assembly. [j] The inspection of HT switch gear shall involve Inspection of Truck & Hoist Assembly, Tank Assembly & Barriers, Assembly & components of Solenoid Assembly, Assembly & components of Dependent Mechanism, Assembly & components of Spring Box Mechanism, Motor Mechanism Spring Charge Assembly and Assembly of Trip Unit & related components in full satisfaction of Engr-in-charge and inclusive of one primer coat with red oxide one under coat , one finishing coat with aluminium paint complete all as specified and directed. (k) Certificate to be provided by OEM after completion of VCB Servicing.
Note:- [a] The rate quoted shall be deemed to be include for necessary T & P, nuts, bolts, washers, gasket, insulation tape, compound, all as per existing etc. to put in to the VCBs and Panels in serviceable condition, testing and commissioning all as specified and as directed. [c] Major spares will be measured and paid separately under relevant items of this BoQ. However, the rate quoted shall be deemed to be include for any other minor spares requires replacement. [d] The servicing shall be carried out by Authorised Service Centre as approved by GE.
S&F in repair voltmeter 500 volts squire type 96 mm including connecting and testing complete all as specified and directed
S&F in repair LED type indicating lamps with holder as per existing at site complete all as specified and directed
Supply, Install, Testing and commissioning of REF 615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 64R, 67, 67N, 27, 59, 59N, 25, 81U, 81O, df/dt, 95, Measurement for 3I, I0, 3U, U0, Kw, KVA, PF, Hz, KWH, 12 DI + 10 DO, One front RJ45 Port, One Rear RS485 Port for Modbus Protocol, Draw out Type with CT Shorting feature, Small LCD Display feature including taking down old relay of any description complete all as specified and as directed by Engr-in-Charge
Supply and fixing in repair of CT's ratio 120/60/5A and any size/capacity as required on site, suitable for VCB under repair with number of poles including wiring upto indicator display board etc complete all as specified and directed
Supply and fixing in replacement of Voltage Transformer (PT) for indoor type VCB ration -11000/110 volt as per existing model and capacity complete and any size/capacity as required on site, suitable for VCB with number of poles including wiring upto indicator display board etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing Spring Chargin Motor with Gearbox Universal Motor with Gearbox 230AC/DC 110V AC/DC complete with all accessories as directed by Engr-in-Charge.
S & F in repairs Space Heater in HT VCB, 11KV Suitable for operation on 220 volts, AC Supply complete with necessary wiring and control cable with Toggle Switch complete all as specified and as directed.
M&L for scraping down the existing deteriorated old aluminium paint by iron brushing and painting of four pole structure with one coat of (metal primer) and two coat of aluminium paint over exposed portion including cross arms, angles, nuts bolts clamps & junction box of above PCC coping and painting to steel tubular HT poles with two coats of synthetic enamelled paint upto 1.5 m height above from ground level/plinth block (in yellow and black strips of 30 cm wide each) complete all as required on site and directed.
M&L for scraping down the existing deteriorated old aluminium paint by iron brushing and painting of two pole structure with one coat of (metal primer) and two coat of aluminium paint over exposed portion including cross arms, angles, nuts bolts clamps & junction box of above PCC coping and painting to steel tubular HT poles with two coats of synthetic enamelled paint upto 1.5 m height above from ground level/plinth block (in yellow and black strips of 30 cm wide each) complete all as required on site and directed.
Repair of Gang operated air break switch 11 KV , 400 Amps, each pole consisting of galvanised steel base HT insulator as per BSS/ ISS non- ferrous knife and spring loaded contacts, arching arms of adequate section to break magnetizing current " TILTING TYPE" complete with square shaft of GI, adequate length for phase separation , operating handle complete set conforming to IS : 1818 with suitable clamp , nuts, bolts complete for fixing on the existing channel, making all electric connections/ Jumpers with bottle lugs commissioning and testing complete all as directed.
M&L for old painted steel and iron surfaces and painting to steel tubular HT poles with two coats of synthetic enamelled paint upto 1.5 m height above from ground level/plinth block (in yellow and black strips of 30 cm wide each) and applying two coats of aluminium paint above 1.5 m height of poles including painting on cross arms, bracing, clamps etc and writing pole Nos with thick black synthetic enamel paint complete all as specified and directed.
M&L in repair for HT underground cable Fault locating instrument suitable to locate and pin point fault in HT cables upto 11 KV and make the cable in operation condition including provision of jointing material which is required on site except cable joint kit, excavation in trenches upto depth of cable, returning filling and removing the extra material on site after completion of work complete all as specified and directed by Engr-in-Charge.
Tightening/restringing existing loose/broken conductor ACSR/ copper any type of size and GI wire including strengthening of HT overhead lines including binding with suitable binding wire and jointing jumpers as required at site and all as specified and directed.
Supply and replacement of silica-gel (dehydrating agent) in position on transformers installed at various location at Haldwani all as specified and directed.
Trimming of trees all as along the HT/LT line in such a way that there is clear distance of 3.00 mtr between tree and electric line including stringing stretching and strengthening of overhead loose conductor (ACSR) on existing HT steel tubular pole or RS joist HT electric pole including binding and jointing the conductor with and including 14 SWG winding wire etc. The work will be executed to the entire satisfaction of Engineer-in-charge irrespective of the size of the tree branches etc complete all as specified and directed. Note: - (1) Tree branches will be left as it is the wood belong to cantt board/DO. They will be responsible for the wood. (2) Contractor will deploy sufficient labour to complete the full one job within 15 days. (3). Contractor will be responsible for any type of accident while trimming the trees. (4) Contractor supervisor will take proper sit down for MES installation before starting the work and clear it before resuming power supply, however full assistant will be provided by MES staff.
M&L in replacement of Epoxy insulators in VCB 630Amps complete all as specified and directed by Engr-in-Charge.
Supply, installation, commissioning and testing of switch Air break, Gang operated with 12 insulator switch triple pole mechanically operated, mounted on insulator and steel frame, with mechanism worked from ground level, for current rating 400 Amps operating voltage 11 KV out door type vertical mounted type complete with locking arrangement , assembly with fuse mount carrier and fuse element of required capacity and isolate suitable for 11 KV including necessary electric connection and 11 KV fuse (drop out type) of capacity 10 Amp complete with DO fuses assembly operating Rod of 25 mm dia bore grade GI Pipe of suitable length worked out from ground level and handle complete with lock and two nos keys including flat iron clamp 50 mm x 6 mm MS Channel of suitable size & length for fixing GOD including nut, bolt, washers including taking down existing set all as directed by Engr-in-Charge.
M & L for providing PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) in base of pole of size 1200mm X 600mm X 200mm complete all as specified and directed
M & L for providing PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) in foundation (1200mm x 600mm x 1800 mm (sub base as mass concrete) for concrete encasing the pole up to GL or struts, stay etc or other necessary form work all as directed and specified.
M & L for providing PCC 1:2:4, type B-1 for coping (using 20 mm graded stone aggregate) of Existing /New electric pole for plinth block/Collar above GL, 300 mm high and 450 mm x 450 mm square or as directed by Engr-in-Charge including Dismantling old coping in pole.
M&L in replacement of Tripping Coil (24V DC) in VCB 630Amps complete all as specified and directed by Engr-in-Charge.
M&L in replacement of Closing Coil (24V DC) in VCB 630Amps complete all as specified and directed by Engr-in-Charge.
M&L in replacement of Power pack 110-volt AC to 24-volt DC in VCB 630Amps complete all as specified and directed by Engr-in-Charge.
M&L for GI tubing light grade 80 mm bore for cable protection laid in trenches/fixed to wall, poles including MS flat iron, clamps, nuts, bolts, etc complete.
M&L for MCCB 4 pole 415V adjustable type 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge.
M&L for MCCB 4 pole 415V adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge.
M&L for MCCB 4 pole 415V adjustable type 250 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge.
M&L for MCCB 4 pole 415V adjustable type 400 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge.
M&L for MCCB 4 pole 415V adjustable type 630 Amps with breaking capacity 50 KA complete all as specified and directed by Engr-in-Charge.
Opening of DG set Air/water cooled and servicing of 7.5 KVA DG set, complete servicing checking of oil, coolant, v-belts, greasing and oiling of parts and cleaning the inner body, tank and radiator etc by removing sludge etc and reassembling the DG set after repair and replacement of unserviceable parts of DG set and testing complete including comprehensive maintenance of DG sets as per B check with providing qualified staff all respect all as specified including engine tuning and replacement of following spare parts (As applicable):-Make : Kirloskar (a) Oil Filter, (b) Fuel Filter, (c) Fuel pipe for high pressure pump,(d) V belt for cooling fan,(e) Coupling, (f) Air Filter, (g) By pass oil filter, (h) Oil Chamber packing set,(j) Flexible hose pipe for air filter, (l) Flexible hose pipe for oil filter, (m) Flexible hose pipe for Fuel filter, (n) fasteners ,clips washer all as required at site.
All as per item No. 74 here in before, but DG Set of 25/30 KVA Make: Kirloskar
All as per item No. 74 here in before, but for DG Set of 40 KVA Make: Kirloskar
All as per item No 74 here in before, but for DG Set of 160 KVA Make: Mahindra
All as per item No 74 here in befoe, but for DG Set of 250 KVA Make: CG
Supply only of following spare parts for item No-74 to 78 above: - Note: - (i) Fixing charges of these spare parts shall be deemed to be included in respective item of Sch A. (ii) The make of different parts under this item shall be of Kirloskar/CG/Mahindra OR as per OEM
Lub oil Engine Oil (20W 40) Make: Servo/ Castrol/Volvoline
Coolant additive Make: -Volvoline/Castrol/Servo
Lead Acid Battery for DG SET 75 Ah Make: - Exide/ Amaron/ Luminous
Lead Acid Battery for DG SET 130 Ah Make: - Exide /Amaron/ Luminous
Lead Acid Battery for DG SET 150 A h Make: -Exide/Amaron/ Luminous
Water Pump Assembly
Metallic Pad Foundation as per Existing
Chamber Packing Set complete
Rubber Hose for main air pipe as per existing sample including steel clips
Distilled water in one/two litre container
Banzo nut Size 19/21mm dia
Container (Bottle) for Coolant as per exiting materials, Shape & Size with fixing arrangement
Water elbow Suitable for 5 to 100 KVA DG Set
Water elbow Suitable for 125 to 250 KVA DG Set
Adjusting bearing as per sample or existing Make/OEM
Cap for Radiator of DG Set as per Sample
S & F in replacement of Battery lead (wire) of size 70 Sqmm copper conductor single core. (Make: Polycab/Finolex/Havells)
M & L for repair/ maintenance to self-starter 12 volts any make including rewinding to self-starter 12 volts by taking out old burnt-out copper winding wire and rewinding with super enamelled copper wire same gauge including replacement of u/s pinion, bush, solenoid coil, carbon brushes& tension spring complete all as specified and directed.
M & L for repair/ maintenance to self-starter 24 volts any make including rewinding to self-starter 24 volts by taking out old burnt-out copper winding wire and rewinding with supper enamelled copper wire same gauge including replacement of u/s pinion, bush, solenoid coil, carbon brushes& tension spring complete all as specified and directed.
M&L rewinding and replacement of cut out, Roller Set Bush Set suitable for dynamo 12 Volt complete in commissioning and testing all as specified and directed.
M&L rewinding and replacement of cut out, Roller Set Bush Set suitable for dynamo 24 Volt complete in commissioning and testing all as specified and directed.
M&L in replacement of push button for starter.
Supply and fix rubber matting of size 1m x 2.0 m, 12 mm thick.
M & L for replacement of Auto contactor 100/5 Amp, AC supply 415 Volt for 25/35/63 KVA capacity DG set in AMF Pannel Make: L&T /Legrand/ C&S
S & F Battery charger of 6/12/24 volt battery Make: L&T /Legrand/ C&S
M & L for primary fuel pump assembly suitable for DG set as per Sample & OEM recommended or as directed by Engr in Charge.
S&F in replacement Engine starting relay with sequence timer & master timer suitable for 12 Volts DC Supply. Make: PIC/L&T/Siemens/BCH
S&F in replacement electronic timer, suitable for 240/415 Volts 50 Hz AC supply for 0-60 seconds ON relay. (Make: PIC/L&T/Siemens/BCH/Haiser or company recommended)
M & L for replacement of water temperature gauge with wiring suitable for 62.5 KVA to 250 KVA as directed by Engr-in-Charge.
M & L for oil pressure gauge with wiring suitable for 62.5 KVA to 250 KVA as directed by Engr-in-Charge.
M & L for replacement of RPM meter with cable as Make: Yankey/Pricol, as directed by Engr-in-Charge.
M & L for replacement of push button switch for starting the DG Set upto 125 KVA Make: Lucas or equivalent as directed by the Engr-in-Charge.
M & L for replacement of ignition switch with key and wiring complete upto 125 KVA as directed by Engr-in-Charge.
M & L of asbestos rope of 10mm dia around the exhaust pipe of diesel engine any capacity completed all as specified and directed by EIC
M & L Volt meter of 4''/4" square dial of range (0.500 Volts) Make: - AE Havells/L&T/MECO.
M&L Amp meter of 4''/4'' Square dial of range (0.100) Amp Make: - AE/Havells/LT/MECO.
M&L indicator lamp with bulb thered & FD type Make: - L&T/Siemens/ Havells.
M&L Frequency meter of checking the output of alternator vibrating read type
Removing the existing 3 phase coil any make up to 40-75 Amps from panel board end re-fix after repair of terminal plate disc pin and set the meter after repair complete all as specified and directed.
M & L for replacement of AVR 30 KVA to 250KVA, Make: Kirloskar /Senelac /CG
M & L for replacement of Hour meter, digital type including cable assembly
Painting of DG Set with one coat of synthetic enamelled paint over a coat of primer including panel board of the colour as approved by Engr-in-Charge complete all as specified and directed by Engr-in-Charge for the following capacity :-
5 to 10 KVA
M & L for replacement of battery lead terminals made of brass and suitable for battery and terminal complete all as specified and directed by the Engr -in-Charge.
M & L for replacement of 12 Volt battery lead set of two suitable for 180 AH capacity, 1.5 Mtr long including GM terminal one end, copper lug other end Engr-in-Charge.
M & L for replacement unserviceable / wear & tear door locking handle of mild steel hinges, for silent type various capacity of DG Set and make good as per existing shape and model, fabricated from structural Galvanised steel sections of any size and shape including nut, bolts, washers, welding, bending, cold or hot drilling holes in bolts of any size all as specified and as directed at site.
Dismantling/Opening of radiator from DG set of capacity 250 KVA and transporting the same to authorised workshop from Site to work shop and back for cleaning and descaling of radiator tubes with suitable chemicals,leakage testing of radiator and repaired it if found leakage & filling coolent as required qty including fixing in position after repair all as directed by Engr-in-Charge. (Note :- Coolent will be measured under relevent items)
Taking down unserviceable having bore 25 mm dia Butter fly handle stop valves, cast copper alloy, screwed down, high pressure, ISI marked complete all as specified and directed.
All as per iter No - 111 here in before but 20 mm bore
All as per iter No - 111 here in before but 15 mm bore
Surface dressing n.exc 15 cm deep incl as in any type soil including taking out all sapling shrubs, brushwood, undergrowth, roots, and trees n. exc 30 cm girth all removing to a distance n.exc 100 m from starting point complete all as specified and directed by Engr-in-charge (The area is to be carried out in and around,structches viz transformes, HT and electric poles over head reservoirs, around power house and pump house and other E/M installation at Haldwani & Ranibagh.
Taking up or down steel tubing of any grade including all GI fitting laid in trenches or on open surface and connections for relaying or removal complete all as specified and directed for the following sizes :-
100 mm dia
80 mm dia
50 mm dia
40 mm dia
25 mm dia
20 mm dia
15 mm dia
Re-fixing of following bore old steel water tubing and connection in new or old position as in trenches including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. Note :- Serviceable GI tubing retreived from item 6 will be reused.
50 mm dia
40 mm dia
25 mm dia
20 mm dia
15 mm dia
Supply and laying in trenches GI tubing medium grade with all fittings (such as bend, elbow, tees, connectons, short pieces, bak nuts, union, valve, caps and plugs etc) for pipe complete all as specified and directed for the following sizes :-
100 mm dia
80 mm dia
50 mm dia
40 mm dia
25 mm dia
20 mm dia
15 mm dia
Taking out sluice valve suitable for 150 mm bore pipe from valve pit for re-facing & re-grinding and re-fixing, including all jointing material such as nut, bolts, washers, rubber gasket/packing 6 mm thick, including glan packing etc and as required at site complete all as specified and directed. Location : Pump House, Haldwani, Ranibagh & Kamola
All as per item No 118 herein before but of size 100 mm size sluice valve
All as per item No 118 herein before but of size 80 mm size sluice valve
Taking out old u/s sluice valve from valve pit or vertical line of O/H tank valve and supply, Install, commissioning and testing of 150 mm size sluice valve of cast iron body flanged & drilled conforming to IS-14846, PN-1.6with stainless steel spindle including all accessories such as nut-bolts, washers & fibre/rubber gasket as required at site complete all as specified and directed.
All as per item No. 121 herein before, but of size 100mm size sluice valve
All as per item No. 121 herein before, but of size 80mm size sluice valve
Taking out old u/s cast iron Non return valve of any type and size for replacement and supplying, fixing, testing and commencing non return valve suitable for 100 mm bore pipe (suction line) both ends flanged including nut bolts, gasket and washer from sump and pump house bldg complete all as specified and directed. Location : Pump House Haldwani, Ranibagh & Kamola
All as per item No. 124 herein before, but of size 80mm size sluice valve
All as per item No. 124 herein before, but of size 50mm size sluice valve
Taking out old u/s cast iron Butterfly valve of any type and size for replacement and supplying, fixing, testing and commencing non return valve suitable for 150 mm bore pipe (suction line) both ends flanged including nut bolts, gasket and washer from sump and pump house bldg complete all as specified and directed. Location : Pump House Haldwani, Ranibagh & Kamola
All as per item No. 127 herein before, but of size 100mm size sluice valve
M&L for de-watering of 100000 Glns capacity under ground water sump including removing fungus, scales slurry etc from the inside wall of the sump, taking out sludge, mud clay deposited at the bottom of the sump and removing the same to a distance not less than 50 mtr, washing the walls of the sump with water and chemical salt as bleaching powder etc and Applying two coat of lime washing on all the internal surfaces of the tank and two coat of cement base on external surfaces of approved make and shade snowcem on all the outside surfaces of the tank and one coat of synthetic enamel paint over the iron/steel surfaces. The entire job is to carried out all as specified and directed by Engr-in-chage. Loc : Haldwani Note :- (i) The contractor shall write the date on which the tank is cleaned with white synthetic enamel paint in bold letter and back ground shall be painted with black paint on wall of UG Tank. (ii) Rate quoted by the contractor shall deemed to be included the same and no extra payment shall be made on this account.
All as per item No 129 herein before but 50,000 Glns capacity. Location : Haldwani
M&L for cleaning of RCC overhead tank of capacity 10000 Glns on 15 Mtr staging from inside, extraction of dust/sand/mud/algae deposits, making it free from algae growth by scrapping and washing with water including or cleaning of the out side surfaces and area surrounding the tank including drains etc. Applying two coat of lime washing on all the internal surfaces of the tank and two coat of cement base on external surface including staging of approved make and one coat of synthetic enamel paint over the iron/steel surfaces. The entire job is to carried out all as specified and directed by Engr-in-chage. Loc : Ranibagh/Kamola Note :- (i) The contractor shall write the date on which the tank is cleaned with white synthetic enamel paint in bold letter and back ground shall be painted with black paint on wall of OH Tank. (ii) Rate quoted by the contractor shall deemed to be included the same and no extra payment shall be made on this account.
All as per item No 131 herein before but capacity 25000 Glns. Location : F/Qty, Haldwani
All as per item No 131 herein before but capacity 50000 Glns. Location : R&O Area, Haldwani
Material & Labour for repair and overhauling of elect motor 30 HP capacity installed with pump set at pump house, Haldwani comprising of the following works :- (a) Dismantling of 30 HP elect motor 3 phase, 440 volts from foundation and taking away local works shop and transporting back the same after repairs. (b) Opening of motor winding, cutting of burnt coils and cleaning of slots complete all as specified and directed. (c) Applying one coat of red oxide primer, fixing of packing with Pnumax paper and green sheet of glass cloth, rewinding with suitable gauge of super enamelled insulated wire (Appx qty- 25 Kg) (d) Making suitable Star/Delta connections for three phase wiring with 6 Sqmm x 6 run (Appx 24 RM) of FRLS wire incl PVC pipe and pin type lugs complete all as specified and directed. (e) Varnishing with doctor bake varnish, during backtrol and heating properly complete all as specified and directed (f) Replacement of u/s rubber star coupling and providing new pin bush coupling complete all as specified and directed. - 01 Nos (g) Repair of Main shaft of pump. (h) Replacement of Pump bearing suitable size and fillup greesh for lubrication complete all as specified and directed. - 02 Nos (j) Repalcement of imppellers suitable size. - 02 Nos (k) Replacement of pump bushes of suitable size. (l) Replacement in repair Gland packing, greasing to brgs. Notes :- Standby electric motor of 30 HP should be provided by contractor at the site without any extra cost.
All as per item No.134 hereinbefore but electric motor of capacity 20 HP installed at MES pump house Haldwani complete all as specified and directed.
All as per item No. 134 hereinbefore but electric motor of capacity 7.5 HP installed at Ranibag complete all as specified and directed.
M&L in repair for opening of CI sluice valve of 150 mm size any type for replacement of defective spindle with stem and providing new spindle with stem made of stainless steel duly machine threaded, heat treated and shaped including cast iron handwheel and making good the stuffing box with suitable size of gland packing and greasing at Haldwani & Ranibagh complete all as specified and directed.
All as per item No 137 herein before but of size 100 mm size sluice valve.
All as per item No 137 herein before but of size 80 mm size sluice valve.
Excavation in trenches by manually or mechanical method n.exc. 10 Sqm on plan, exc. 1.5 m deep but n.exc. 3.0m in deep for foundation etc. in any type of soil including taking out old filler material from the mild steel pipe joint including cleaning of joints and making the joints completely water tight and air tight by means of lead joint & filler material to the entire satisfaction of Engineer in charge including retuning/ filling, to be done after joints are sealed complete all as specified and directed. Note :- The rate quoted by the contractor shall deemed to included of all T & P and material , nothing extra shall be paid.
M & L for repair and replacement of contactor/relay with necessary connected partrs including wire in startor panel of 30 HP at pump house Haldwani
M & L for repair and replacement of contactor/relay with necessary connected partrs including wire in startor panel of 20 HP at pump house Haldwani
Supply and fix changeover switch AC side handle 4 pole , 415 Volt 63 Amp, on load side handle operated complete all as specifide and directed .
Supply and fix changeover switch AC side handle 4 pole , 415 Volt 100 Amp, on load side handle operated complete all as specifide and directed .
Supply and fix changeover switch AC side handle 4 pole , 415 Volt 200 Amp, on load side handle operated complete all as specifide and directed .
Supply, install and commissioning of Multi-Cavity Power-free automatic erosion feed enabled water sanitizer / conditioning treatment station with proportional dosing arrangement consisting of, Receptacle with following attachments: Water Inlet Regulator, Overflow Vent, Water Outlet Regulator with non-return valve (for standalone gravity flow), Water Outlet Regulator (for offline automated gravity flow), Drain valve, Fluid Level controller, Sludge Level Guage, Station Base Assembly with Station Base Buffer, Station Hood Assembly with multi-cavity arrangement (13), Station Holding Assembly, Material of construction: Non-metallic thermoplastic, Maximum Temperature: 45°C, 100 Ltr. Tank, In-built Level Switch & Processor, ½ inch Processor Outlet & Processor Inlet connections, Flexible Connecting Duct, Material of construction: Non-metallic, Cavities are compieted with Lids. Additional Fittings: 6 metre Suction Tubing, PVC Ball Valve, Plastic check valve, Hose nipple, Compatibility: Stequa 411 AE Refill with all assessary complete all as specified and directed. Model-STEQUA ADS PRO System.
Supply and fix Chlorine tablets contained in plastic cylindrical sealed disposable sanitiser refill for disinfection of drinking, water with arrangement for controlled release of disinfectant in water, suitable for operation through, recommended dosing system. Replacement indication: visual & weight variation, Water contact orifice design: Sealed when dry, exposed upon immersion, Operation type: Non contact, non inhalatory, Cylinder dia: 2.5 inches ± 0.5 inches, Cylinder height: Minimum 10.0 inches ± 0.5 inches complete all as specified and directed. Model- STEQUA 411 AE REFILL
M&L plain cement concrete 1:2:4, type B-2, using 40mm graded stone aggregate in foundation filling, mass concerete and sub base of ploes, struts, stay etc. including necessary form work complete all as directed by Engr -in-Charge and specified.
M & L for Welding/DI Joint of GI leakage pipe 50 mm to 150 mm size by electric resistance uniform thick welding by providing electric supply upto location using suitable size of electrode and other pipe lifting and safety equipments including necessary excavation and earth work in any type of soil as required etc (quoted rates shall be deemed included the cost of such provision) complete all as specified and directed.
M & L for Cleaning of valve pit chambers, removing algae, silt, sludge accumulated at bottom of valve pit chambers up to the entire satisfaction of Engineer in Charge complete all as specified and directed.
Taking down unserviceable gate valves of bore 50 mm for replacement including S & F Gun-metal, gate valves ISI Marked with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
All as per item No. 151 here in before but 40 mm bore
All as per item No. 151 here in before but 25 mm bore
All as per item No 151 here in before but 20 mm bore
All as per item No 151 here in before but 15 mm bore
S & F Water level sensor for overhead tank with An electronic, electrically operated water level indicator that displays 10 levels in an overhead tank (reservoir) uses sensors like float switches or ultrasonic sensors to determine water level. The system then sends electrical signals to a display panel that shows the water level in increments of 10% (or similar). These indicators can also include alarms to alert users when levels are too high or too low. The system to have alarm by pass and different indication in case of use of alarm by pass including provision of copper conductor twelve core Teflon coated copper conductor cable with multi strand as required for fixing one indicator set complete with control switch Gear Pannel with MCB DP-16Amp.
Supply and fixing or passing through pipe, stranded conductor 6 Sqmm, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers no more than 1 meter apart including 4 mm suspension wire, one twin core cable flat or circular etc all as specified and directed.
All as per item No. 157 here in before, but 10 Sqmm.
All as per item No. 157 here in before, but 16 Sqmm.
Supply and fixing LED Security/Street light fittings 60 watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant inclding thermal management in multiple optics complete with IP 65/66 Protection with GI Pipe light grade bracket 1.2 mtr long 40 mm dia fixed to wall with suitable size 2 Nos MS Clamps including nuts, bolts and washers and making connection with using 1.5 sqmm pvc insulated multi standard copper conductor three single core complete all as specified and diredted.
Supply and fixing LED Security/Street light fittings 35 watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant inclding thermal management in multiple optics complete with IP 65/66 Protection with GI Pipe light grade bracket 1.2 mtr long 40 mm dia fixed to wall with suitable size 2 Nos MS Clamps including nuts, bolts and washers and making connection with using 1.5 sqmm pvc insulated multi standard copper conductor three single core complete all as specified and diredted.
Supply and fixing post top lantern LED type 20Watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.
Supply and fixing post top lantern LED type 40 Watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.
Supply and fixing LED flood light 70 watt, 230 V AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and average life of flood light not less than 50000 hours, including clamps, nut, bolts, fixing in wall including 2 sqmm PVC twin core aluminium cable from conductor to street light not less 2.0 metre, testing to satisfaction of Engineer in charge complete all as specified and directed.
M&L for earthing complete with galvanized sheet earth plate electrodes 60x60 cmx6.3 mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of plat not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to and including the earth test point of galvanized Iron/ steel of size 75x75x25mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia TMT bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering and connected to earth test point including brazing at all joints except at test point and testing complete all as specified and directed.
M & L Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed by Engr-in-Charge.
M & L Test terminal block made of gun metal or phosphorus bronz size 75 x 75 x 25 mm drilled and screwed including 3 nos 8 mm dia 25mm long he. Head screw complete all as specified and directed by Engr-in-Charge.
Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engr-in-Charge.
Suppy, fixing, transporting, erecting and fixing steel tubular swaged pole type 410 SP- 31 (09 metres long) complete with cast iron base plate, finial taper plug MS bolts, and washers incuding two coats of aluminium paint over a coat of red oxide primer to external surfaces of steel tubular pole and two coats of anti corrosive bituminous paint internally and externally upto planting depth of pole and providing 3 bands/ straps with paint red post office colour and 2 bands with black synthetic enamel paint 300mm from plinth block and marking pole No. with black synthetic enamel paint and feeder location of Pole including earth work/excavation in any type of soil PCC 1:4:8 type D-2 in foundation below pole, PCC 1:3:6 type C-2 around pole and plinth block of pole, disposal of surplus soil to a distance n.exc 50m and depositing where directed including dismantling of existing damaged steel pole/struts etc complete all as specified and directed.
Supply and fixing pin type, porelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Engr-in-charge.
Supply and fixing shakle type, porelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts in repair insulators suitable for working pressure in 1100 volts of height 75 mm and max dia 90mm alongwith galvanised steel fittings section of straps in 31X3 mm and dis of bolts 12mm complete all as specified and directed by Engr-in-charge.
M&L for MCCB 4 pole 415V adjustable type 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge.
M&L for MCCB 4 pole 415V adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge.
M&L for MCCB 4 pole 415V adjustable type 250 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge.
M&L for MCCB 4 pole 415V adjustable type 400 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge.
M&L stay assembly complete comprising of 7/3.15 galvanised stranded stay wire of required length fixed to pole with and including FI clamp 50x6mm size, bolts, nuts washers, galvanized steel stay rod 16mm dia and 1800 mm long , stay bow 400 x 14 mm galvanised steel plate 230 x 230 x 6 mm two numbers , thimbles loop insulator size 90 x 140 mm clearance hole 16 mm including earth work/excavation in any type of soil, PCC 1:3:6 type C-2 in foundation of stay assembly, disposal of surplus soil to a distance of 50m including two coats of aluminium paint over a coat of red oxide primer on exposed mild steel work including dismantling existing stay assembly etc complete all as specified and shown in electric plate No 1 and directed.
M&L for stringing of over head aluminium conductor steel reinforce (ACSR) on existing LT steel tubular pole or RS joist LT electric pole including binding and jointing the conductor with and including 14 SWG winding wire etc complete all as specified and directed. Weasel (6/1x2.59 aluminium and 1x2.59 steel) Note:-Any breack or damage insulator has been change and the cost of insulator has beed deemed in item rate.
Trimming of trees all as along the LT/HT line in such away that there is clear distance of 3.00 mtr between tree and electric line. The work will be executed to the entire satisfaction of Engineer-in-charge irrespective of the size of the tree branches etc complete all as specified and directed. Note :- (1). Tree branches will be left as it is the wood belong to cantt board/DO. They will be responsible for the wood. (2) Contractor will be employ sufficient labour to complete the full one job with in above 15 days (3). Contractor will be responsible for any type of accident while trimming the trees. (4) Contractor superviser will take proper sit down for MES installation before starting the work and clear it before resuming power supply, however full assistant will be provided by MES staff.
Labour for stringing stretching and stengthening of over head conductor (ACSR) on existing LT steel tubular pole or RS joist LT electric pole including binding and jointing the conductor with and including 14 SWG winding wire etc all as specified and directed.Weasel (6/1x2.59 aluminium and 1x2.59 steel) Note ;- (i) Cutting/trimming of tree branches all around the LT over head conductor of any span upto 1.5m away including removing the same may included the rate quated. (ii) Any breack or damage insulator has been change and the cost of insulator has beed deemed in item rate.
Supply and fixing or passing through pipe, stranded conductor 6 Sqmm, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers no more than 1 meter apart including 4 mm suspension wire, one twin core cable flat or circular etc all as specified and directed.
All as per item No. 182 here in before, but 10 Sqmm.
All as per item No. 182 here in before, but 16 Sqmm.
Supplying, commissioning & testing of Time light distribution board/street light timer switch with anolog time switch with battery backup, 3P module, 24 hours program, programmabel 15 min, backup of 100 hrs, current capacity 16A, with 1 changeover (1 CO) 40 Amp 3 pole/230V Analog time switch with enclosure system in mounting arrangement and tripping mechanism alongwith suitable capacity of control MCBs as per INDOASIAN Cat Part No. TL040ABO or its equivalent approved make of L&T, C&S & Havells complete all as specified and directed. Note : Contractor shall submit 1 year warranty of distribution board from manufacturer alongwith purchase voucher.
S&F cable jointing kit for 1.1 KV grade cable for stairght through joint complete with jointing material (Epoxy based) and accessories suitable for 3.5 core XLPE armoured Al conductor cable of size 95 sqmm to 150 sqmm.
All as per item No. 186 here in before, but cable of size 35 sqmm to 70 sqmm.
S&F cable jointing kit for 1.1 KV grade cable for end joint complete with jointing material (Epoxy based), Aluminium Lugs/thimbles and accessories suitable for 3.5 core XLPE armoured Al conductor cable of size 95 sqmm to 150 sqmm.
All as per item No. 188 here in before, but cable of size 35 sqmm to 70 sqmm.
All as per item No. 188 here in before, but cable of size 16 sqmm to 25 sqmm.
M&L for old painted steel and iron surfaces and painting to steel tubular LT poles with two coats of synthetic enamelled paint upto 1.5 m height above from ground level/plinth block (in yellow, Red and black strips of 30 cm wide each) and applying two coats of aluminium paint above 1.5 m height of poles including painting on cross arms, bracing, clamps etc and writing pole Nos with thick black synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Supply and Fixing pole mounting box / junction box made out of 1.66mm thick MS CRCA sheet / fibar sheet of size 230 x170 x 105 mm complete suitable for three phase connection with clamps of flat iron/GI off size 25 x 4 mm including suitable size nut, bolts, washer etc to fix on pole and provide with hinged door and locking system all painted with two coats of synthetic enamel paints over one coated red oxide paint and comprising of the following :- (i) AI busbar 150mm long size 20 x 50 mm fixed on four Nos porcelain insulator each busbar provided with four Nos of Nuts, bolts, washer for incoming and out going cable. (ii) MCB SP 230V 5 to 32A, 10 KA – 1 Nos.
Supply , laying , connecting, testing and commissioning 95sqmm 3.5 core under ground LT cable XLPE insulated screened, PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts laid in trenches, fixed to walls/ drawn through pipe and including the disturbence surface of road making good with using PCC, fixing the cable with suitable size glands, crimping type lugs etc all as specified and directed. Note;-(Excavation, earthwork sand cushioning and cable protection shall be measured and paid for separately.)
All as per item No. 194 here in before, but 35 Sqmm 3.5 core
All as per item No. 194 here in before, but 10 Sqmm 2 core
M&L for brick sub class 'B' old size brick for protection of cable complete all as specified and directed.
M&L for GI tubing light grade 40 mm bore for cable protection laid in trenches/fixed to wall, poles including MS flat iron, clamps,nuts, bolts, etc complete.
M&L for GI tubing light grade 80 mm bore for cable protection laid in trenches/fixed to wall, poles including MS flat iron, clamps,nuts, bolts, etc complete.
Supply and Fixing A heat shrink sleeve for Low Tension (LT) cables is a heat-shrinkable plastic tube used to insulate and protect cable connections, joints, and terminations. , common solution for restoring cable insulation, providing environmental sealing, and offering mechanical protection, particularly in electrical wiring. The sleeve is typically made of polyolefin, a flexible and flame-retardant material, and shrinks when heated, creating a tight, insulating fit. size of LT cable XLPE LT cable 95 Sqmm to 120 sqmm 3.5 core
All as per item No. 200 here in befoe, but cable of size 35 sqmm to 70 sqmm.
All as per item No. 200 here in before, but cable of size 16 sqmm to 25 sqmm.
Mahamaya Engineers Services (BID ID -3444314)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .