| 3 | L3₹33.5 L+₹4.6 L (16.1%)Rejected-AOC OPP JASWANT PLAZA BAWA TRADING COMPANY CAMP ROAD TALAB TILLO JAMMU JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L3 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 4 | L4₹33.7 L+₹4.9 L (17.0%)Rejected-AOC | L4 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 5 | L5₹35.9 L+₹7.0 L (24.4%)Rejected-AOC | L5 | Rejected-AOC Other than lowest tendrer hence rejected |
Tender Value
Refer Docs
EMD Value
₹77,500
Closing Date
27 Oct 2020, 6:00 pmClosed
CWE MAMUN
HQ CWE MAMUN PATHANKOT 145001
SPECIAL REPAIR TO BLDG NO P-45 (BATHROOM ONLY) AT SHIVAJI LINE AND BLDG NO P-74 (OR MD ACCN) AT CHOPRA LINE UNDER GE SAMBA
2020_MES_372111_2
CWE/M-35/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE SAMBA
Class D Category a i
6 documents required · 6 mandatory
₹500
Yes
GE SAMBA
₹77,500
Yes
24 Dec 2020
5 Oct 2020
28 Oct 2020
5 Oct 2020
27 Oct 2020
15 Oct 2020
Amount
Taking down chowkhats or frames of any description not exc 1.50 Sqm each with shutters, (without taking off shutters from the frame) including builders hardware , complete all as specified and directed.
Taking down chowkhats or frames of any description exc. 1.50 Sqm and n.exc 4.00 Sqm each with shutters, (without taking off shutters from the frame) including builders hardware complete all as specified and directed.
Taking down Shutters of any description exc 1 sqm and n exc 2 sqm each including builders hardware complete all as specified and directed.
M&L for pressed steel frames 125mmx60mm for door, made out of 1.25 mm thick MS sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plate and back filling for chowkats in PCC (1:3:6) type C-0 (using 12.5mm graded crushed stone aggregate) tarring ends incl 02 coats of synthetic enamel paint over a coat of red oxide primer on exposed surface complete all as specified and directed.
M&L for pressed steel frames 105mmx60mm for door, made out of 1.25 mm thick MS sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plate and back filling for chowkats in PCC (1:3:6) type C-0 (using 12.5mm graded crushed stone aggregate) tarring ends incl 02 coats of synthetic enamel paint over a coat of red oxide primer on exposed surface complete all as specified and directed.
M&L for 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12mm veneered particle board with commercial veneering on both faceS ,The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated, fitted to chowkhats incl 02 coats of synthetic enamel paint over a coat of pink primer after preparation of surfaces complete all as specified and directed.
M&L for 35mm thick glazed and skeleton shutters (Factory made) of 2nd class hard wood and prepared to receive glass or gauge etc with rounded, chamfered or mitred sash bars edges of framing plain chamfered or rounded fitted with cut and mitred beads and fitted to chowkats for securing glass/gauge, size of stiles rails and other parts as per clause 8.24 (a) of SSR Part-I 2009 (Larger size to be provided) incl 02 coats of synthetic enamel paint over a coat of pink primer after preparation of surfaces complete all as specified and directed.
Taking down cement plaster on brick or stone walls,etc including racking out joints , hacjking for keys,scrubing down with water etc, and removal of rubbish out off the permises complete all as specified.
Demolition of plain cement concrete (unreinforced) as in ground floors & pavings not exceeding 15 cms thickness below or above grounds levels complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding complete, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Complete removal of existing roof treatment surface and Roughening surfaces and prepartion of old concrete surface by picking sweeping, clening & washing down with water remove dust of old concrete floor by picking, sweeping clean and washing down with water to remove dust complete all as specified and directed.
M&L for Box type Steel windows and ventilators comprised of tubular frame and shutters made out of 1.25mm thick M S sheet tube factory made with double side hung wire gauged shutter & glass/glazed shutter (wire cloth and glass panes only shall be measured and paid separately) with steel handle and steel peg stay dovetailed or welded incl 2 Nos. tower bolts 150mm long for each leaf and 10mm square bar grills at spacing as shown on drg, welded to F I frame work, including other fittings; hinges, handles, tarred hold fasts fixed in PCC blocks all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for Factory made solid PVC Moulded door shutter, 28 to 30 mm thick (style), with 2, 4, or 6 raised panel design with 5mm thick Moulded prelam PVC Sheet on the front face & 5mm prelam colour PVC sheet on back face, supplying & fixing at site as per specification & drawing complete all as specified and directed.
S&F Stainless steel wire (grade 304) cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks, orstainless steel wire staples complete all as specified and directed.
M&L for 4mm thick sheet glass ordinary quality and glazing with oil putty or fixed with beads/ glazing pins not .exc 0.5sqm in each pane complete all as specified and directed.
M&L for 4mm thick sheet glass ordinary quality and glazing with oil putty or fixed with beads/ glazing pins not .exc 0.5sqm in each pane as in repair complete all as specified and directed.
S&F Second class hard wood of frame size 100mmx75mm fixed with Aluminium Louvers including 4mm thick figured glass frame put together with glue, pinned at joints, supplied and fixed complete all as specified and directed.
M&L for stainless steel Butt hinges of size 100 mm fixed with steel screws of appropriate size complete all as specified and directed.
M&L for 250mm aluminium sliding door bolt with hasp & staple (bolt type) and fixing clip of sheets cast or extruded section and fixing sliding bolt of extruded section etc complete all as specified and directed.
M&L for aluminium anodized barrel tower bolts 200 mm of extruded section and fixed. complete all as specified and directed.
M&L for Aluminium anodised handle, extruded section of size 150mm etc complete all as specified and directed.
M&L for 150 mm MS helical door spring plate type including roller and roller plate complete all as specified and directed.
M&L for 150 mm long aluminium floor door stopper of aluminum aloy body and tongue anodized with hard drawn steel spring complete all as specified and directed.
S&F Hasp and staple aluminium anodized 100mm long including bolt to hinge plate and fixed with screws, complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-290(GdeE-165) complete all as specified and directed.
M&L as in repair for 18/19mm thick Block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work , with decorative face veneer on both faces, fixed as in kitchen cabinet, cupboard and pelmet box fixed with screws to PVC/timber frame work complete all as specified and directed.
M&L as in repair for 25mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides if both faces, complete all as specified and directed.
M&L for 18/19mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
S & F Continuous (piano) hinges, width of flats (when open) size 40mm thick mild steel, bright finish or electrogalvanised for complete all as specified and directed.
M&L for factory made PVC internal UPVC (rigid) door frame of the size 100mm x 45mm with a wall thickness of 5mm, made out of extruded 5mm thick, PVC sheet of density 600kgs/cubic metre manufactured by an ISO-9000 certified company, mitre cut at two corners and joined with 4 Nos of 150mm long brackets of 15mm x 15mm MS square tube of 19 guage through out the frame. The door frame shall be fixed to the wall using 65/100mm long MS screws through the frame by using anchor fasteners. A minimum of 4 Nos of screw to be provided for each vertical member & minimum 2 Nos for horizontal members etc. complete as per manufactures specification and directions of Engr-in-Charge.
S&F in repair for 20mm bore Mild steel powder coated, single curtain rod (wall thickness not less than 1mm) including fancy type PVC brackets of approved design/pattern, funnels etc suitable for single curtain rod complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc and removal of rubbish out off the premises complete all as specified and directed.
M&L for Brick work with Sub Class 'B' brick (Non-Modular) straight or curved on plan to any radius in half brick thick walls built in (1:4) etc complete all as specified and directed.
M&L for Brick work with Sub Class 'B' brick (Non-Modular) Class 7.5, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed.
M&L for preparation of new plastered surface of walls applying two coats of cement base paint over a coat of alkali resistent priming paint as per manufacturer instructions complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and apply three coats of white wash on plastered surfaces complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description in any position complete all as specified and directed.
S&F 15 mm bore Stop valves/Angle valve cast copper alloy, chromium plated (ISI marked) , screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed.
S&F in repair for single towel rail brass chromium plated 600mm long fixed with chromium plated screw and PVC cleat complete all as specified and directed. Make : Cat part No AQN-7711 of Jaquar or equivalent model in Hindware/Marc.
S&F in repair for looking mirror frame less, bevelled edge, fancy type area exc 0.5 Sqm but nexc 1.2 Sqm, 5mm thick complete all as specified and directed.
M&L for Vitreous china wash hand basin, white, oval type, size 635mmx430mmx190mm (Make : Jaquar Cat part No SRT-WHT-39601 or equivalent model in Hindware/Parryware/Somany) including 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated (Make : Jaquar Cat part No FLR-5011N or equivalent model in Hindware/Marc.) brackets, CP waste coupling, 32mm bore PVC waste pipe of min 600mm long & 15 mm bore PVC connections, including cutting for and pinning in end of brackets or erecting stand fixed in repairs complete all as specified and directed.
S&F in repair for 15mm bore bib taps fancy type with wall flange, chromium plated cast copper alloy long body with capstan heads, screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F in repair for 15mm bore pillar cock cast copper alloy, chromium plated (ISI marked) , screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed. Make : SSSCO Cat Part No. TQT 5104 or equivalent model in Jaguar/Marc/Jainco
Taking up or down 15mm bore pipe and connections including cleaning for refixing including all new fittings for 15mm bore complete all as specified & as directed.
Taking up or down 20mm bore pipe and connections including cleaning for refixing including all new fittings for 20mm bore complete all as specified & as directed.
M&L for GI water tubing surface/concealed, 15mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor, complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not exc 10 cm girth complete all as specified & directed.
M&L for GI water tubing surface/concealed, 20mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor, including taking down existing unserviceable GI tubing and connections complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
S&F 15 mm bore Stop valves cast copper alloy, screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed.
S&F 20 mm bore Stop valves cast copper alloy, (ISI marked) screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surface in CM (1:6) on wall surfaces finished even and smooth without using extra cement complete all as specified & directed.
M&L for rendering 10mm thick on brick work or concrete surface in CM (1:3) on ceiling/chhajja surfaces finished even and smooth without using extra cement complete all as specified & directed. [Note : WPC shall be measured and paid seperately under respective item.]
M&L for Rendering 15mm thick in two layers [base layer 10mm IN CM 1:6 & finishing layer 5mm thick in cement mortar (1:4)] using liquid water proofing compound in IInd layer only on brick work or concrete surfaces of wall, surfaces finished even and smooth using extra cement including taking down cement or cement lime plaster of any description and raking out joints, hacking for key, scrubbing down with water and removal of rubbish, out off the premises, etc complete all as specified & directed. (Note : WPC shall be measured and paid separately)
M&L for preparation of newly plastered surfaces of wall & applying two coats of distemper oil emulsion (OBD) over a coat of primer as per manufacturer instructions (from same manufacturer of OBD) over and including a layer of wall care putty 2mm thick complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall & applying one coats of distemper oil emulsion (OBD) complete all as specified and directed.
M&L two coats of white wash on surface of ceiling including preparation of old plastered surface by washing rubbing, stopping brooming down with steel wire brushing scrapping down smoke roots, moulds salts and trading oil and greasy spots complete all as specified and directed.
M&L for Chequered cement concrete tiles (PU coated) of size 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over and including 20mm thick screed bed in cement mortor 1:4 over and including 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) etc complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection laid in panels and joints filled with mix of bitumen 85/25 grade and sand (1:2) by weight, finished the surface even and smooth using extra cement etc complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in coping, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed finished the surface even and smooth without using extra cement etc complete all as specified and directed.
M&L for 25 mm thick floor in PCC 1:2:4 type B-0 (12.5mm graded crushed aggregate) as in sub base of floor, complete all as specified and directed.
M&L for Non-skid ceramic coloured rectified edges tiles (joint free) 8mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:6), including dismantling existing floor tiles of any type and pattern including cement mortar bedding and removing debris/tiles out off the premises, etc complete all as specified and directed.
M&L for Non-skid ceramic coloured rectified edges tiles (joint free) 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floors etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:6), including dismantling existing floor tiles of any type and pattern including cement mortar bedding and removing debris/tiles out off the premises, etc complete all as specified and directed.
M&L for Non-skid ceramic coloured rectified edges tiles (joint free) 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in skirting/dado/riser of steps etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 10mm thick screed bed or bedding layer of cement mortar (1:4), including dismantling existing floor tiles of any type and pattern including cement mortar bedding and removing debris/tiles out off the premises, etc complete all as specified and directed.
M&L for Glazed ceramic (coloured) tiles 7mm thick, of size 450mmx300mm on vertical surfaces such as dado etc, set and jointed in neat cement slurry and pointed in coloured epoxy grout to match tiles over and including 10mm thick backing coat in cement mortar (1:4), surface finished even and rough to receive tiles, including dismantling existing tiles of any type and pattern including cement mortar backing coat and removal of rubbish out off the premises complete all as specified and directed.
M&L for 16 to 18mm thick Marble work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rounding & chamfering to the edges of granite not exceeding thickness 20 mm thick , laid over and including 15mm thick screed bed in CM 1:4 including Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc & Brushing neat cement slurry with 3.0kg of cement per sq. metre including dismantling of existing tiles/stone etc complete all as specified and directed.
M&L for 18 to 20m thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rounding & chamfering to the edges of granite not exceeding thickness 20mm thick , laid over and including 15mm thick screed bed in CM 1:4 including Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc & Brushing neat cement slurry with 3.0kg of cement per sq. metre including dismantling of existing tiles/stone etc complete all as specified and directed.
M&L for 20mm thick Machine cut kota stone slab flooring over and including 20mm thick screed bed in CM 1:6 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and directed.
M&Lfor 20mm thick Machine cut kota stone slab as in steps, riser of staircase, skirting, dado and including 10mm thick screed bed in CM 1:3 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and directed.
S&F for Vitreous china White Squatting Orissa Pattern pan (Make : Somany Cat part No 121115 or equivalent model in Cera/Hindware/Parryware) of size 580x440mm, including cast iron ‘P’ or ‘S’ trap, front or back inlet and integral foot rests and making connection to trap and to flushing pipe, anti syphonic pipe,including provision of PCC 1:7:12 type F-2 (using 40mm graded crushed stone aggregate) bedding including demolition complete all as specified and directed. (Note : Demolition and refilling of concrete in sunken portion is included in the Contractor quoted rate.)
S&F in repair Brass Chromium Plated shower rose with arms fancy type with swivel joints 75 mm face dia of appoved make and cat part for 15mm bore iron pipes complete all as specified and directed. Make : Prayag Cat part No BS-73 or equivalent model in Hindware/Marc.
S&F in repair for PVC flushing cistern dual flush typevalve-less syphonic action type, low level, complete with inlet, ball valve, handle, including brackets/pins, PVC flush pipe 32mm bore complete all as specified and directed.
S&F in repair for PVC connection 15mm size with PTMT nuts of length 450mm long of appoved make complete all as specified and directed.
S&F in repair C.P Brass stop cock valve (fancy type) 15 mm bore, cast copper alloy screwed down, high pressure, screwed both ends for iron pipe or unions (concealed type) complete all as specified and directed.
S&F in repair for Rotational moulded polyethylene water storage tanks three layer of capacity 500 litre, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm float valve high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball and dismantling of existing PVC tank of any capacity, complete all as specified & directed.
S&F in repair for Stainless steel sink with draining board 1mm thick sheet for kitchen with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm, including 32mm bore PVC waste outlet pipe of minimum length 600mm complete all as specified and directed. Make : Blue star Cat part No. BSSBSD-52 or equivalent model in Nirali/Jyoti
S&F Stainless steel plate rack of approx size 750x900mm fixed with chromium plated screw and PVC cleat complete all as specified and directed. Make : Blue star Cat part No. KPR-312 or equivalent model in Nirali /Jyoti
S&F in repair for Vitreous china white wash down water closet pan (pedestal pattern) with normal closing seat cover S-trap/P-trap (Make : Jaquar Cat part No CNS-WHT-553SN or equivalent Cat Part/Model of CeraHindware/Parryware/ Somany) & hand shower (Health foucet) 1.5m long flex tube in chrome finish and wall hook with NRV (Back flow preventer) and connection to drain (or out going pipe) (Make : Jaquar Cat Part No ALD-563 or equivalent Cat Part/Model of Hindware/Parryware) and to flush pipe, antisyphonic pipe etc complete all as specified and directed
S&F in repair for Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe size (Minimum weight 60gms) etc complete all as specified and directed. Make : Jaquar or equivalent in model in Cera/ Hindware/Parryware)
S&F in repair for Vitreous china urinal partition white slabs of size 310mmx700 mm.terminating about 40cm above floor line of size complete all as specified and directed. Make : Jaquar or equivalent in model in Cera/ Hindware/Parryware)
Dismantling of PVC (SWR) DRAIN PIPES UPTO 110MM DIA drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
M&L for application of Perma hypercreate with cement on bath room floor slab and sunken portion, ratio (1:1) hypercreate and cement, surfaces finished smooth complete all as specified and directed. Make : Perma Guard/Dr Fixit/STP/Fosroc/Sika
M&L for application of 'Perma guard' with mash fibre jalli, two components water proofing coating material applied in two coats to a thickness of 1 mm, material (perma guard) used @4 sqft/kg, perma guard is two component chemical (8:2) 8 Kg powder and 2 litre liquid complete all as specified and directed Make : Perma Guard/Dr Fixit/STP/Fosroc/Sika
M&L for application of Second coat 'Perma guard' with mechanical mixing, ensured pinhole free coating, avoid mixing of ingradient of packing in part, consume the mixed material used within 30 minutes complete all as specified and directed. Make : Perma Guard/Dr Fixit/STP/Fosroc/Sika
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F PVC (SWR) pipes of size 110 mm dia bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipes of size 110 mm dia bore single socketed in any length with rubber ring joints fixed to walls using necessary clamps complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipes of size 75mm dia bore single socketed in any length with rubber ring joints fixed to walls using necessary clamps complete all as specified and directed.
PVC (SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F PVC (SWR) 110mm bore bends any radius complete all as specified and directed.
S&F PVC (SWR) 75mm bore bends any radius complete all as specified and directed.
S&F PVC (SWR) 110mm bore bends any radius with access door complete all as specified and directed.
S&F PVC (SWR) 75mm bore bends any radius with access door complete all as specified and directed.
M&L for preparation of new wooden surface of any description over 10cm width or girth and applaying two coats of synthetic enamel paint over a coat of pink primer after preparation of surfaces complete all as specified and directed.
M&L for preparation of old wooden surface of any description over 10cm width or girth and applaying one coats of synthetic enamel paint after preparation of surfaces complete all as specified and directed.
M&L for preparation of new steel or iron surface of any description over 10cm width or girth and applaying two coats of synthetic enamel paint over a coat of redoxide primer after preparation of surfaces complete all as specified and directed.
M&L for preparation of old steel or iron surface of any description over 10cm width or girth and applaying one coats of synthetic enamel paint after preparation of surfaces complete all as specified and directed.
M&L for preparation newly plastered surface of walls and applying two coats of weather proof paint on walls over and including a coat of 2mm thick wall care putty complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall & chajja and making the surface smooth with sand paper & applying one coat of cement base paint as per manufacturer instructions including curing complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 using (12.5 mm graded crushed stone aggregate) as leveling course/padding using water proofing compound laid over existing roof, surface finished rough to receive cement mortar including necessary formwork complete all as specified and directed. Note : (WPC shall measured and paid separately)
Supply only Polymer liquid water proofing compound of make Pidilite/Bauchemic/Fosrock, all as specified and directed.
M&L for APP modified roof treatment over existing non accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification complete all as directed :- (a) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufactured by the same agency as that of APP with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (b) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane, Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (c) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (d) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
M&L for demolition of cement concrete (reinforced) of any description in any position not otherwise specifically provided for cement concrete (reinforcement cut as required to faciliate demolition) complete all as specified and directed.
S&F in repairs tubular towel rai, chromium plated, 60cm long between flanges complete all as specified and directed.
M&L for Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for providing precast reinforced cement concrete (1:1.5:3) type A-1 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary form works complete all as specified & directed.
M&L for RCC 1:1½:3 Type A-1 using 20mm graded crushed stone aggregate as in chajjas, facias including necessary formwork complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately)
M&L for Plain cement concrete(1:3:6) Type C-2( using 40mm graded crushed stone aggregate ) as in drains including necessary formwork complete all as specified and directed.
Taking down carefully unserviciable/ damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc ) and removing material from site and making good to the disturbed surface to match with existing finish complete all as specified and directed.
M&L for Modular Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box and approved make sunken modular metal flush gang box and suitable support frame and cover plate (inner/outer) of required modules for mounting modular switches/ sockets etc, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point complete all as specified and directed. (Note : Modular switch/bell push/fan regulator etc shall be measured and paid separately under respective items.)
All as per Srl item No. 110 above but for one ceiling/exhaust fan point controlled by one switch, single pole, one way, 5 Amp, 240 volts etc complete all as specified and directed.
All as per Srl item No. 110 above but for one bell/buzzer point controlled by one bell push, single pole, 5 Amp, 240 volts etc complete all as specified and directed.
All as per Srl item No. 110 above but for one multipin socket (5 pin) controlled by one switch, single pole, 5 Amp, 240 volts on the same board etc complete all as specified and directed.
All as per Srl item No. 110 above but for one multipin socket (5 pin) controlled by one switch, single pole, 5 Amp, 240 volts on independent board etc complete all as specified and directed.
M&L for Modular point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable 2.5 sqmm including 2.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box and approved make sunken metal flush gang box and suitable support frame and cover plate (inner/outer) of required modules for mounting modular switches/ sockets etc, for one 6 pin socket outlet 15 amps, Modular multi purpose independent point controlled by 15 Amp switch Single pole , one way , 240 volts connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point complete all as specified and directed. (Note : Modular switch/bell push/fan regulator etc shall be measured and paid separately under respective items.)
M&L for Sub main wiring with FRLS PVC insulated unsheathed 2X4 sqmm multistranded copper conductor cable 1100 V with 1X4 sqmm FRLS PVC insulated green multistranded copper cable for continuous earth drawn through & including concealed PVC conduit of appropriate size not less than 20 mm dia & 1.8mm wall thickness with all accessories including cutting grooves and making good disturbed surface to match existing including taking down existing surface sub main wiring complete all as specified and directed. (Note: Two runs of FRLS PVC cable with one run of earth conductor and conduit shall be measured as one RM.)
S & F modular switch piano type flush button one way, single pole 5 Amp one module complete all as specified and directed. Make : Legrand Cat Part No 673000/Crabtree Cat Part No ACMSXXW101/Anchor Roma Cat Part No 66111.
S&F Modular switch Socket outlet, 5 pin, multi purpose 2 module 6 Amps, AC 230 volts, etc complete all as specified and directed. Make : Crabtree (Verona) Cat Part No : ACVKSWW065 or equivalent of Legrand/Siemens/Schenider/Anchor Roma.
S&F modular switch Socket outlet, 2 in 1, 6 pin, ,5/15 Amps, flush type (ISI Marked ) AC 230 volts, etc complete all as specified and directed. Make : Crabtree /Legrand / Schneider /Siemens/Anchor Roma
S&F modular Switch piono flush button single pole one way 15 Amp (ISI Marked ) AC 230 volts, etc complete all as specified and directed. Make : Crabtree /Legrand / Schneider /Siemens/Anchor Roma
S&F modular switch bell push flush 06 Amp (ISI marked) complete all as specified and directed. Make : Legrand / Anchor Roma / Schneider /Siemens/Crabtree
S&F door Bell Ding Dong AC 230 Volt, single Pole etc complete all as specified and directed. Make : Anchor Cat Part No 8024 or equivalent of Havells(Reo)/SSK (Topline)/GM (Vyoma)
S&F Ceiling rose polycarbonate isolated body surface Bakelite, not less than 65 x 50 mm, three terminals, AC 230 volts etc, complete all as specified and directed. Make : Havells Cat Part No Reo/Cona Cat Part No 9246/GM Cat Part No 8224
S & F Fan regulator modular step type suitable for 1200/1400mm sweep ceiling fan hum free, 120W- 2 module including necessary connections complete all as specified and directed. Make : Legrand Cat Part No 673028/Crabtree Cat Part No ACARFHW005/Anchor Roma Cat Part No 66502.
S&F Lamp holder insulated body with back plate suitable for batten fitting including 12W LED lamp of approved make and cat part and PVC Round/Square block etc complete all as specifeid and directed.
S &F in replacement the Bulk head light fitting LED type 10 watt complete with 10 watt LED and having IP-63 protection and fixing on wall/ceiling complete with all accessories and including connecting up with ceiling rose with & including PVC insulated and overall sheathed flexible copper conductor cable and including 3 core 0.50 Sqmm complete all as specified and directed.
S &F as in repair high efficiency LED linear tube 1x 18 watts , 6500K AC 230 volts, wall batten complete with all accesories internally prewired and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Notes for Srl Item Nos 125 to 127 :- 1. Driver shall be potted antivibration type. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be povided. 3. CRI (Colou Rendring Index) of fixture shall be > 70. 4. CCT (Colout Correlated Temprature of fixture shall be 5700K ± 300 K. 5. System Lumen Efficacy shall be > 100Lm/W 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years gurantee shall be provided by contractor suppoted by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the Contractor shall replace / repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair 11. CA No shall be written on each fitting before installation. 12. The name of manufacturer to be embossed on the fitting. 13. The fittings shall have arrangement so that maintaince required, if any can be carried out from Top cover.
S&F MCB single pole (SP) 240 volts, 6 to 32 Amps, 10KA (C-series) , complete all as specified and directed. Make : Legrand/Schneider/Hager
S&F MCB single pole neutral (SPN) 240 volts, 63 Amps, 10KA (C-series) complete all as specified and directed. Make : Legrand/Schneider/Hager
M &L for Double door MCB DB SPN, 415 Volts, 04 Way made out of CRCA powder coated sheets, IP43 protection with copper bus bar with including taking out old unserviciable MCB DB any size/type, complete all as specified and directed. Make: Legrand or equivalent IN PERFORMANCE IN model in L&T/Hager/SCHNEIDER
M &L for Double door MCB DB SPN, 415 Volts, 08 Way made out of CRCA powder coated sheets, IP43 protection with copper bus bar with including taking out old unserviciable MCB DB any size/type, complete all as specified and directed. Make: Legrand or equivalent IN PERFORMANCE IN model in L&T/Hager/SCHNEIDER
S&F MCB Triple pole neutral (TPN) 415 volts, 50 Hz 63 Amps, 10KA (C-series) complete all as specified and directed. Make : Legrand/Schneider/Hager
M&L for water heater storage type elctric capacity 25 litres , BEE 5 star rated with set of hot & cold flexible connection pipe and coneccting electrically complete all as specified & directed Make: Recold or equivalent IN PERFORMANCE IN model in /Havells/Bajaj
M&L for RCCB SPN 240Volts , 40 Amps and sensitivity 30 mA with breaking capacity of 10 KA complete all as specified & directed Make: Legrand or equivalent IN PERFORMANCE IN model in L&T/Hager/SCHNEIDER .
S&F Venti Air /Exhaust Fan single phase, 230/240 Volts of size 300mm sweep with loure of metalic body with nut bolts and making the suitable hole for 300mm sweep exhaust fan by breaking the exiting and making the plastring and matching with existing surface /specification , complete all as specified and directed. Make : Crompton Greaves Trains Air Exhaust/ Bajaj Bahar 300mm/Havells Ventilair DXW6
M&L for earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, HDPE pipe 15mm bore as protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels .
SIDDAHANT ENTERPRISES
M/S BAWA TRADING CO
THAKUR BUILDERS AND CO
M/S NAGAR BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .