Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.2 L+₹1.1 L (3.64%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹30.4 L+₹1.2 L (4.28%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹34.0 L+₹4.9 L (16.8%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹40.5 L
EMD Value
₹81,000
Closing Date
8 Feb 2020, 6:00 pmClosed
CWE KOTA
HQ CWE Kota Military Engineer Services Dadwara Military Station Kota Rajasthan PIN 324002
CWE KOTA/PLN-69OF 2019-20 SPECIAL REPAIR TO BLDG NO P-69 UNDER AGE I PILANI
2020_MES_315515_1
81551/PLN/E8
Open Tender
Civil Works
Item Rate
180 days
PILANI
For Enlisted Contractors Class D Category a i and for unenlisted contractors meeting enlistment criteria for required Class and Category
7 documents required · 7 mandatory
₹500
AGE (I) PILANI
₹81,000
Yes
6 Mar 2020
16 Jan 2020
10 Feb 2020
16 Jan 2020
8 Feb 2020
3 Feb 2020
16 Jan 2020 - 25 Jan 2020
Amount
B/R PORTION. Taking down cement plaster any description, on brick, PCC block or stone walls, etc. including raking out joints, hacking for key & scrubbing down with water, etc. & removing rubbish off the premises, complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material complete all as specified directed.
Demolition of cement concrete in any description and position not otherwise specifically provided for complete all as specified and directed.
Taking down chowkhats or frames not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as specified and directed.
Taking down shutter of any description n exc. 1 sqm each and removing from site complete all as specified and directed.
Taking down shutter of any description exc. 1 sqm but n.exc 2 sqm each and removing from site complete all as specified and directed. .
Dismantling of plain or corrugated steel sheeting of any guage thickness including Nainital or similar pattern roof coverings, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
Dismantling old unserviceable existing PVC water tank of capacity exceeding 2000 Ltrs but not exceeding 3000 Ltrs and removing from site complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal complete all as specified and directed :-
15mm bore.
20mm bore.
25mm bore.
Dismantling of cement concrete tiles in floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition and breaking up drain pipe of 100mm dia (salt glazed stone ware, AC or reinforced concrete) set in cement mortar including PCC bedding and haunching etc complete all as specified and directed.
Supply only liquid integral water proofing compound complete all as specified and directed. Make :- URP Pidiproof of Dr. Fixit or equivalent.
S & F 30mm thick factory made glazed and skeleton door shutters open rebated of second class hard wood rail and styles(Hollock), prepared to receive glass/gauge etc without sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed. Note :- S & F Glass/gauge shall be measured and paid for separately.
S&F 32mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides etc complete all as specified and directed.
S & F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as applicable to item 08095 given in SSR Part - II (2010) complete all as specified and directed.
S & F Factory made solid PVC moulded door shutter, 28 to 30 mm thick (style), with 2, 4 or 6 raised panel design with 2mm thick moulded prelaminated PVC sheet on the front face & 2mm thick plain colour PVC sheet on back face, supplying and fixing in frame at site as all as per specifications and drawings as applicable to item 08101 & 08102 given in SSR Part – II, complete all as specified and directed.
M & L for preparation of old surfaces or unplastered decoarated surfaces of ceiling and applying one coat of distemper oil emulsion of any tint complete all as specified and directed.
M & L for praration of old surfaces of walls and applying one coat of distemper oil emulsion of any tint complete all as specified and directed.
Blank
M&L for preparation of newly plastered surfaces on wall and applying two coats of Oil Bound Distemper over a one coat of 1mm thick wall care putty on new wall surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces on wall and applying two coats of Apex paint over a one coat of primer on new wall surfaces complete all as specified and directed.
M&L for complete removal of existing treatment on surfaces of walls, including cleaning of any mortar drops, fungus efflorescent salts etc and applying two coats of Exterior emulsion paint complete all as specified and directed.
M&L preparation of old painted wooden surfaces of any description and applying one coat of synthetic enamel complete all as specified and directed.
M&L preparation of newly wooden surfaces of any description and applying two coats of synthetic enamel paint over one coat of pink primer including preparation of surfaces complete all as specified and directed.
M & L for preparation old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint of any tint complete all as specified and directed.
M & L for PCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in coving in sunken portion of slab and like including necessary form work complete all as specified and directed.
M&L PCC 1:5:10 type E-2 using 40mm graded stone aggregate in foundation, filling and mass concrete in sunken portion of slab etc complete all as specified and directed.
M&L rendering 10mm thick on brick surfaces or concrete surfaces cement mortar 1:6 mixed WPC finished even and smooth complete all as specified and directed. (Note :- Supply only WPC shall be measured and paid separately)
M&L rendering 15mm thick on brick surfaces or concrete surfaces cement mortar 1:4 mixed WPC finished even and smooth complete all as specified and directed. (Note :- Supply only WPC shall be measured and paid separately)
S&F GI tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed for following sizes:-
15mm bore.
20mm bore.
25mm bore.
S & F in repair Cast iron soil, waste and vent pipes (spun pipes), 100mm bore of pipe, in any length with or without ears, with cement joints, laid in trenches or in floors but fixed to wall and tested complete all as specified and directed.
S & F in repair Cast iron soil, waste and vent pipes (spun pipes), 75mm bore of pipe, in any length with or without ears, with cement joints, laid in trenches or in floors but fixed to wall and tested complete all as specified and directed.
S & F in repair 19/20 mm thick prelaminated particle board both sides with decorative choice laminations fixed with screws to timber frame/aluminium frame as in partitions, shelves, cup board or similar items open edge of board fixed with screws etc complete all as specified and directed.
S & F Cast iron floor trap 100mm dia outlet plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 complete all as specified and directed.
S & F 100mm bore bends cast iron of any radius with dimenshing pieces or taper (larger bore measured), complete all as specified and directed.
S&F 100mm bore cast iron branch pieces, single, (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branch complete all as specified and directed.
M&L for one coat of cold bituminous primer @ 0.40 litres/Sqm on plastered surfaces including side wall and a layer APP based polyster non woven fabric(weighing not less than 150gm/Sqm) wieghing 3 Kg/Sqm minimum and 3 mm minimum thickness shall be alid on primed surfaces by torch application, complete all as specified and directed.
S & F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed complete all as specified and directed.
S & F in repairs Brass Hat and coat hooks, solid body of size 175mm to 250mm complete all as specified and directed.
S & F in repairs aluminium Hasp and staples 100mm plate type, complete all as specified and directed.
S&F continuous (Piano) hinges width of flaps (when open) 40mm, MS, bright finish or electro galvanised complete all as specified and directed.
S & F mild steel flate iron as in hold fast, bands straps, support or stays of eves board etc. complete all as specified and directed.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F in repair Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S & F 4mm thick plain sheet glass, ordinary quality and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
S & F 4mm thick plain sheet glass, ordinary quality and glazing with oil putty in squares exc 0.5 sq. m in each pane complete all as specified and directed.
S & F 4mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sqm in each pane complete all as specified and directed.
S&F 100mm long MS butt hinges medium weight cold rolled mild steel complete all as specified and directed.
S&F 75mm long MS butt hinges medium weight cold rolled mild steel complete all as specified and directed.
S & F 200mm long aluminium anodised barrel tower bolts of extruded section and fixed, complete all as specified and directed.
S & F 100mm long aluminium anodised barrel tower bolt of extruded section and fixed, complete all as specified and directed.
S & F in repair 200mm long aluminium anodised barrel tower bolt of extruded section and fixed, complete all as specified and directed.
S & F 300mm long aluminium anodised barrel tower bolt of extruded section ISI marked complete all as specified and directed.
S & F in repair 300mm long aluminium anodised barrel tower bolt of extruded section and fixed, complete all as specified and directed.
S & F 150mm size extruded aluminium alloy handles fabricated type anodized ISI marked complete all as specified and directed.
S & F in repair 150mm size extruded aluminium alloy handles fabricated type anodized ISI marked complete all as specified and directed.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F in repairs 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F in repairs 90 mm long alluminium alloy, anodised, floor door stopper consisiting of rubber bush at bottom, foloding type, fixed on door shutter with using screws, complete all as specified and directed.
M & L for non skid jointless ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38mm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed.
M & L for non skid jointless ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38mm as in skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed.
M & L for non skid jointless ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile 300mmx300mm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed.
M&L 450x300x7 mm thick glazed ceramic coloured tiles as in vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as specified and directed.
M&L 20-22mm thick machine cut Kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing for laying floor finishes complete all as specified and directed.
M&L 20-25mm thick machine cut Kota stone slab in riser of steps, skirting, dado, shelves and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
S & F for aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
S & F powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinges type B-21 100mm long (2 No.) suitable hhandle (1 no.) complete all as specified and directed.
S & F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handles & steel pag stay complete with glazing bars, dovetailed or welded including fixing of lugs in PCC 1:2:4, type B-1, using 20mm graded stone aggregate & making good walls & cills to match the existing complete all as specified and directed.
M & L for screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6, for laying floor finishes complete all as specified and directed.
M & L for screed bed, 10 mm thick, in cement mortar 1:4, forfixing wall tiles finishes complete all as specified and directed.
"S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick (wider vallley type) of any colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self tapping screws complete all as specified and directed. (Make :- DURASHINE/ TATA BLUE SCOPE/CRIL)"
S&F mild steel work in tubular trusses, purlins including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 including notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts including rivets or nuts and bolts, providing and fixing cleats, fish plates, gusset plates etc and also for wedging, plumbing, turning up & fixing complete all as specified and directed.
M & L Granite (of any type) tiles 15 to18mm thick machine cut in skirting /dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
S & F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed.
M&L 15 to 18mm thick granite (any type) machine cut, bedded screed bed and jointed with grey cement slurry and pointed with white cement with admixure of pgment to match the shade of granite stone including cutting and polishing in any shape complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4), complete, all as specified & directed.
S & F in repair wash hand basin oval under counter type of size 500x450 coloured fixed in 18mm thick polished black granite slab including making oval shaped opening in granite slab, nosing on edges, brackets etc. complete all as specified and directed. Make:- CNS-WHT 705 of Jaguar or Equivalent). Note : Granite Slab shall be measured and paid seperately under relevent item in schedule.
S&F in repair 15mm bore brass chromium plated fancy type long body bib cock with flange complete all as specified and directed. Make:- JAQUAR Code. CON-107KN or equivalent
S&F in repairs chromium plated towel rail chromium plated screws complete all as specified and directed. Make:- JAQUAR Code. AEC-1111 or equivalent
S&F 15mm bore stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
S&F 20mm bore stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
S & F in repairs CP central basin mixer with U shaped round casted spout with 450mm long baried houses complete all as specified and directed. Make : JAQUAR Code CON-169KNB or equivalent.
S&F 25mm bore stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
S & F in repairs brass chromium plated, fancy type shower rose 80mm dia with swivel joint including fixing to steel pipe or union complete all as specified and directed. Make : JAQUAR Code ALE-536A or equivalent.
S & F grating doom 125mm dia PTMT (Minimuim weigth 25 Gms), Complete all as specified and directed.
S&F 15mm bore concealed stop cock with with long shank chromium plated wall flange cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed. Make:- DLX 514E of Jaguar or Equivalent as specified in Appendix 'D'.
S&F15mm bore angle valves chromium plated fancy type, complete all as specified and directed. Make: JAQUAR, Code DLX 526 or Equivalent as specified in Appendix 'D'.
S & F PVC connection 15mm dia 450mm long with chromium plated check nut and washer etc complete all as specified and directed.
S&F in repairs, PVC low level cistern 10 litres capacity, valve less, symphonic action type with float, handle including 32mm dia PVC flush pipe of polyethylene of low or high density & bracket etc complete all as specified and directed.
S&F hand shower (health facut) 8mm dia, 1.50 mtr long flexible tube with wall hook complete all as specified and directed.
S&F in repair vitreous China squatting pan, Orissa pattern, size 580mm x 440mm white with integral foot rests (excluding flushing cistern and flush pipe etc) including making good to floor complete all as specified and directed.
S & F vitreous China urinals of size 305x305x440mm, Half stall type, white providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flushing cistern with brackets, flush pipe grating and union for dishcharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia complete all as specified and directed.
M & L cast iron floor trap, with dia of outlet 75 mm with grating and including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S & F in repairs white Vitreous china wash down water closet pan & trap (pedestal pattern) including plastic water closet seat, white/black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device including flush pipe to pedastal pan including all joints incl connections to drain pipe and flush pipe etc complete all as specified and directed.
S & F 3000 litres, rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top), hoisted and fixed in position and including PTMT 20mm float wall with high density plastic ball complete all as specified and directed. Note : PVC tanks shall be ISI marked and having two layers.
Cleaning and removing all scale and dirt, etc, from tanks 2000 litres, and from mouths of circulating pipes, etc and reconnecting and re-fixing in position complete all as specified and directed.
S & F in repair ball valve high pressure of PTMT suitable for 20mm bore pipe (minimum weight -210Gm) with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Reparing / re-plastering to air washer duct by removing plastering, thermocol and ckicken mesh etc repair/re-shape by using necessary machinary and plastering the same by using 40 mm thick thermocol sheet al-around securing the same by suitable binding material and re-plastering by using chicken mesh and 10 mm thick cement plaster 1:3 all as specified & directed.
E/M PORTION Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including teak wood battens or from existing conduits with all fittings, such as switches, ceiling rose, pendants, sockets, lamp holder, fan regulators, sketch/brackets light fittings etc but excluding ceiling fan and removal of old material from site and making good disturbed surfaces of walls, floors ceiling etc to match with existing surfaces, complete all as specified and directed.
M & L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn through and including PVC rigid non metallic conduit and conduit accessories concealed in walls/ceiling/floors with sunk type pressed steel terminal box and 3 mm thick plastic laminated sheet top covers at every turning point all as per IS including 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable (green colour) as earth continuity conductor to common earth & connecting to earth dolly for the following :- Notes : (i) The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces. (ii) Flush boxes, cover plate with frame, ceiling rose, light fittings, switches, sockets, regulators, bell push etc shall be measured and paid separately under respective items of BOQ.
One light point controlled by one, one way switch.
One ceiling fan/ exhaust fan point controlled by one, one way switch.
One 5 Amp socket outlet/switch socket outlet on same board.
One 5 Amp socket outlet/switch socket outlet on independent board.
M & L for point wiring complete for 15 Amps socket outlet on independent board with 4.0 Sqmm single core multistranded copper conductor of 1100 volts gradePVC insulated and unsheathed FRLS cable through and including PVC rigid non metallic conduit and conduit accessories concealed in walls/ceiling/floors with sunk type pressed steel terminal box and 3 mm thick plastic laminated sheet top covers at every turning point all as per IS including 4.0 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable (green colour) as earth continuity conductor to common earth & connecting to earth dolly Notes : (i) The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces. (ii) Flush boxes, cover plate with frame, switches, sockets etc.shall be measured and paid separately under respective items of BOQ.
S & F, modular socket outlet multipurpose for three and five pin combined, 10 Amp, 240 Volts, 2 Module type complete all as specified & directed. Make :- Havells/Anchor (Roma)/Cona
S & F, modular socket outlet multipurpose for three pin combined, 16 Amp, 240 Volts, 2 Module type complete all as specified & directed. Make :- Havells/Anchor (Roma)/Cona
S & F modular switch, 1 way 10 Amp 240 Volts, 1 module ISI marked complete all as specified and directed. Make :- Havells/Anchor (Roma)/Cona
S & F modular switch, 1 way 20 Amp 240 Volts, 1 module ISI marked complete all as specified and directed. Make :- Havells/Anchor (Roma)/Cona
S & F white cover plate with frame 2 Module complete all as specified and directed.
S & F white cover plate with frame 3 Module complete all as specified and directed.
S & F white cover plate with frame 6 Module complete all as specified and directed.
S & F white cover plate with frame 8 Module complete all as specified and directed.
S & F concealed GI sheet metal box 16 guage with earth terminal 2 Module complete all as specified and directed.
S & F concealed GI sheet metal box 16 guage with earth terminal 3 Module complete all as specified and directed.
S & F PVC concealed GI sheet metal box 16 guage with earth terminal 6 Module complete all as specified and directed.
S & F concealed GI sheet metal box 16 guage with earth terminal 8 Module complete all as specified and directed.
S & F angular lamp holder, PVC / polycarbonate insulated body type with back plate suitable for batten fittings complete all as specified and directed.
Supply and fix in repair LED tube light fitting 1x20 Watt 230 Volt 4 feet T-5 LED batten ingrated type aluminium extruded etc complete with all accessories internally pre-wired and including fixing the fitting on wall / ceiling with suitable PVC round block -02 Nos, internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and all as directed. Make - C &S Cat Part No : LTTB4F20WLED/W or equivalent as specified in appendix ' D'
Supply and fix in repair LED tube light fitting 1x10 Watt 230 Volt 2 feet T-5 LED batten ingrated type aluminium extruded etc complete with all accessories internally pre-wired and including fixing the fitting on wall / ceiling with suitable PVC round block -02 Nos, internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and all as directed by Engineer-in-Charge. Make - C &S Cat Part No : LTTB4F10WLED/W equivalent as specified in appendix ' D'
S & F in repair fancy type LED decorative wall light fitting single arm with B-22 holder including 12 watt LED lamp complete all as specified and directed.
S & F modular fan regulator electronic step type, 100W, 2 module and making all necessary connections, complete all as specified and directed. Make : Anchor (Roma)/Havells/Cona.
S & F in replacement of TV outlet complete all as specified and directed.
S & F in replacement modular telephone socket RJ11 socket jack , 1 module complete all as specified and directed.
S & F ceiling rose, three terminal, PVC / polycarbonate insulated body, 240 volt, ISI marked complete all as specified and directed.
S & F in repair sheet metal enclosure with a two pin earth plug and socket complete concealed/surface with plug top alongwith MCB Single Pole of capacity 6-32 Amps rating including fixing accessories complete all as specified and directed.
S & F in repair distribution board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyster or with epoxy powder coating and IP-43 protection concealed mounting SPN 4 way, 240 volts with bus barr rating 200 Amps, dust and vermic proof sutiable for incorporation of MCB's and isolators etc. making good disturbed surfaces to match with existing shade complete all as specified and directed. .
S & F in repair distribution board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyster or with epoxy powder coating and IP-43 protection concealed mounting SPN 2 way, 240 volts dust and vermic proof sutiable for incorporation of MCB's and isolators etc. making good disturbed surfaces to match with existing shade complete all as specified and directed.
S & F in repair distribution board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyster or with epoxy powder coating and IP-43 protection concealed mounting TPN 12 way, 415 volts with bus barr rating 200 Amps, dust and vermic proof sutiable for incorporation of MCB's and isolators etc. making good disturbed surfaces to match with existing shade complete all as specified and directed.
S & F MCB TPN 100 Amps, 240 volts, AC supply with over load and short circuit protection and rupturing capacity not less than 10KA including making connection complete, all as specified & directed.
S & F MCB TPN 63 Amps, 240 volts, AC supply with over load and short circuit protectionand rupturing capacity not less than 10KA including making connection complete, all as specified & directed.
S & F MCB TPN 40 Amps, 240 volts, AC supply with over load and short circuit protection and rupturing capacity not less than 10KA including making connection complete, all as specified & directed.
S & F MCB SPN 40 to 63 Amps, 240 volts, AC supply with over load and short circuit protection and rupturing capacity not less than 10KA including making connection complete, all as specified & directed.
S & F MCB 6-32 Amps, 240 volts, AC supply with over load and short circuit protection and rupturing capacity not less than 10KA including making connection complete, all as specified & directed.
S & F in repair MCCB four pole 100 Amps, 35KA, ICS=100% ICU, 415 volts with fixed thermal-magnetic setting including spreader terminal /thimble of suitable size including making connection complete, all as specified & directed.
S & F in repair MCCB sheet metal enclosure suitable for holding MCCB 100-200 Amps, four pole type including fixing accessries etc complete, all as specified & directed.
S & F for submain wiring with 2 single core PVC insulated & PVC unsheathed FRLS cable 1100 Volt grade with 2.50 Sqmm copper multistranded conductor drawn through and including PVC conduit fixed on concealed in wall/ceiling/truss etc. including one run of 2.50 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth and connecting to earth dolly and including taking down old u/s sub main wiring complete all as specified and directed. Note: - Two runs of main cable, one run of earth continuity conductor and one run of conduit will be measured and paid as one length only.
S & F for submain wiring with 2 single core PVC insulated & PVC unsheathed FRLS cable 1100 Volt grade with 4.00 Sqmm copper multistranded conductor drawn through and including PVC conduit fixed on concealed in wall/ceiling/truss etc. also including one run of 4.00 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth and connecting to earth dolly and including taking down old u/s sub main wiring complete all as specified and directed. Note: - Two runs of main cable, one run of earth continuity conductor and one run of conduit will be measured and paid as one length only.
S & F for submain wiring with 2 single core PVC insulated & PVC unsheathed FRLS cable 1100 Volt grade with 6.00 Sqmm copper multistranded conductor drawn through and including PVC conduit fixed on concealed in wall/ceiling/truss etc. also including one run of 6.00 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth and connecting to earth dolly and including taking down old u/s sub main wiring complete all as specified and directed. Note: - Two runs of main cable, one run of earth continuity conductor and one run of conduit will be measured and paid as one length only.
S & F for submain wiring with 2 single core PVC insulated & PVC unsheathed FRLS cable 1100 Volt grade with 10.00 Sqmm copper multistranded conductor drawn through and including PVC conduit fixed on concealed in wall/ceiling/truss etc. also including one run of 10.00 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth and connecting to earth dolly and including taking down old u/s sub main wiring complete all as specified and directed. Note: - Two runs of main cable, one run of earth continuity conductor and one run of conduit will be measured and paid as one length only.
S & F ceiling fan 1200mm sweep , 5 star including connecting up with 3 core flexible cord of size 23/0.0076mm from ceiling rose to fan complete all as specified & directed. Make:- Havells/CG/Bajaj/Khaitan.
Taking down existing Ceiling fan of any sweep, dismentling blade, cleaning properly and painting with one coat of synthetic enamelled paint by means of spray painting, minor repair like changing of capacitor, bearing etc and refixing the same after testing of fan complete all as specified and directed.
Taking down existing Exhaust fan of any sweep, dismentling blade, cleaning properly and painting with one coat of synthetic enamelled paint by means of spray painting, minor repair like changing of capacitor, bearing etc and refixing the same after testing of fan complete all as specified and directed.
Taking down existing Ceiling/Exhaust fan of any sweep, dismentling blades and deposit in store complete all as specified and directed.
S&F Exhaust fans AC single Phase 230/240 V of size 300mm sweep, 1400 RPM, metal body (Heavy duty) with louvers including necessary fittings and making of holes for fixing the same and connecting up with 3 core cord flexible from ceiling rose to exhaust fan etc complete all as specified and directed. Make : Havells/CG/Bajaj/Khaitan.
S & F Exhaust fans AC single Phase 230/240 V of size 450mm sweep, 1400 RPM , metal body (Heavy duty) with louvers including necessary fittings and making of holes for fixing the same and connecting up with 3 core cord flexible from ceiling rose to exhaust fan etc complete all as specified and directed. Make : Havells/CG/Bajaj.
Supply and fix building security light new generation energy saving and environmental friendly long life versatile powder coated pressure die cast aluminium compact IP-66 roadway luminaire with high power LED as light with heat resistant toughened glass with lens source and exclusively designed polly corbonated cover alongwith electronic driver of cap 30W with all accessories including provisions of GI bracket, clamps, Nut, bolt etc complete all as specified and directed. Make : C&S Cat Part No LTEFI30WHPLED equivalent as specified in appendix ' D'
Supply and fix in repairs LED flood lights 50W, LED flood light luminaire with high pressure die cast aluminium housing and IP 66 protection complete with all accessories complete all as specified and directed. Model/Make : Cat Part No LHEFI50WHPLED of C&S or equivalent as specified in appendix ' D'
Supply, installation & testing electric Geyser (water storage type) of capacity 25 litre, vertical mounting type, stainless steel inner tank, rust proof outer body, 2 KW heating element anti corrosive magnesium anode rod, suitable for 230V Single Phase 50 Hz AC supply, 5 Star rating, energy efficient, 8 Kg/sqcm pressure withstanding capacity, Class I, ISI marked, with & including Thermostat with Thermal Cutout, heating indicator, Multi functional valve (acts as pressure release valve, non-return valve, expansion valve and vacuum release valve), steel flexible 2 feet long 2 Nos fixed all as per manufacturer’s instructions, fixed with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of 10mm dia 150mm long with nuts & washers) into the wall grouted properly to hold the geyser and making good the disturbed surface as original, complete, all as specified & directed. Make:- Crompton Greaves/Racold/ V Guard/ Jaquar & Company Pvt Ltd.
Taking down carefully storage water heater (Getsers) of capacity 25/50 ltrs any type and Make Bajaj/Racold after remocal of inlet/ outlet connections, transportation to the workshop, opening up geysers for descaling of inner tank including bracing/ gas welding etc. to make it full functional, insulation material scrapping, cleaning, filling, re-assembling the same after repair/ replacement and fixed to its original position, testing and commissioning complete all as specified and directed. Note:- All the spares for replacement shall be measured and paid separately under respective item of BOQ as "Supply only".
Supply only heating element of capacity 2.0 KW for any type/ Make capacity of Geyser, ISI marked, complete all as specified and directed. Make:- Bajaj/Racold.
Supply only Thermostat ISI marked sutiable for geyser of any type/ Make and capacity including making necessary electricity connection and testing the geyser, complete all as specified and directed. Make:- Bajaj/Racold.
Supply only pressure release safety valve with vent ISI marked sutiable for geysers of any type/ Make and capacity including match with existing, complete all as specified and directed.
Supply only storage water heater (Geysers) steel inner tank of capacity 25 ltrs any type and Make - Bajaj/Racold including PUF/Fible glass wool and match with existing with nuts, bolts etc. complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized strip 25 x 4mm earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of strip and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 3 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing complete all as specified and directed. Notes :- (i) Outer edge of earth pit shall be 1 metre away from the outer edge of PCC chamber. (ii) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (iii) The cost of excavation, earth work is included in the quoted rate.
Earth continuity conductor or main earthing strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc as required GI strip 25x4mm by means bolt and nuts, check nuts and washers all as spepcified and directed.
M/S Sulakh Brothers
S.R.Enterprises
MAHI PALL CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .