Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.4 LAccepted-AOC 24 85 7 SANATH NAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L1 | Accepted-AOC Lowest Bid Accepted | |
| 2 | L2₹74.9 L+₹1.5 L (2.02%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹82.2 L+₹8.8 L (11.9%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | L4₹94.9 L+₹21.5 L (29.2%)Rejected-Finance DOOR NO 50 53 2 5 FLAT NO 504 SRI SAI VENKATESHWARA RESIDENCY NE LAYOUT SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L4 | Rejected-Finance Not Being Lowest Bidder | |
| 5 | Rejected-Technical DOOR NO 65 4 64 1A KOTHA NAKKAVANIPALEM MALKAPURAM POST VISAKHAPATNAM 530011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | - | Rejected-Technical Rejected due to non-submission of EMD |
Tender Value
₹87 L
EMD Value
₹1.6 L
Closing Date
20 Mar 2023, 6:00 pmClosed
Shri KK Srivastava, Col, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
PROVISION OF GAS GODOWN AT WASTE MANAGEMENT CENTRE AND AS and AS TO GI PIPE LINES, REPAIRS TO SUNKEN FLOORS OF CERTAIN BUILDINGS AT NAUSHAKTI VIHAR UNDER GE ND, VISAKHAPATNAM
2023_MES_579997_1
82310
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Class C
Category a i
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Depot
₹1.6 L
Yes
1 May 2023
9 Feb 2023
22 Mar 2023
9 Feb 2023
20 Mar 2023
2 Mar 2023
9 Feb 2023 - 16 Feb 2023
Amount
Excavation over areas not exceeding 1.50 m in depth and getting out in Soft / loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and getting out in Soft / Loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and getting out in hard/ dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and depth exceeding 1.5m but not exceeding 3.0m and getting out in Soft / Loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
Removal of excavated material [Soil] to a distance exceeding 250m and not exceeding 500 m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
M & L for Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rolled with power road roller of 8 to 12 ton capacity and consolidated to required gradient and camber complete all as specified.
M & L for PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
M & L for RCC M–30 Design Mix, using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc. complete all as specified.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts etc. complete all as specified.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels etc. complete all as specified.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in bands, coping and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M & L for providing RCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in Precast Landings, Cover Slabs [for manholes etc], Chullah Hoods, Chajjas, Water Troughs, Mangers, Shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and as directed.
M & L for PCC 1:2:4, Type B-1 [using 20 mm graded granite stone aggregate] in surface channels and drains including forming fair finished drain or channel of any inner girth using extra cement including forms, moulds, mitred / stooped ends complete all as specified and as directed.
M & L for PCC 1:3:6, Type C-1, using 20 mm graded stone aggregate as in Coping and the like including weathering, slightly rounded or chamfered angles and throating including formwork [straight or curved] complete all as specified and directed.
M & L for Providing Precast Cement Concrete Solid Block Masonry of 1:3:6, Type C1 using 20mm graded stone aggregate exceeding 100mm width with plain or interlocking joints set in cement mortar 1:6 complete all as specified and as directed.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
M & L for Broken Glass Coping on top of wall in Cement Mortar 1: 3 complete all as specified and directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits [if any] of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces complete all as specified and as directed. sides of concrete
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions of any shape / cross section for fair finished surfaces of concrete complete all as specified and as directed.
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc, splays between floors and beams and similar works for fair finished surfaces of concrete complete all as specified and as directed.
Use and removal of steel formwork to Edges of Concrete Flats, Treads, Breaks in Floors, Window Cills, Concrete Railings, openings in Concrete Walls, Floor and Roofs, sides of RCC / PCC Bands in Walls, horizontal or sloping and similar work not exceeding 5cm wide for fair finished surface of concrete complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Roof Trusses [framed], trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing [Beam, tee, angle, channel or flat sections] including distance pieces, cleats etc complete all as specified and as directed.
S & F pre-painted Galvalume steel sheets of Trapezoidal profile having pitch 190mm, depth 29mm or Tiled Profile and thickness 0.50mm [Galvalume base-PPGL trapezoidal profile sheets], having tensile strength of 550 Mpa, fixed with aluminium self tapping screws, neoprene and EPDM washers of suitable size in roof covering complete all as specified and as directed. Note: Overlap shall be provided as specified by the manufacturer.
S & F pre-painted Galvalume steel Plain Sheets and thickness 0.50mm [Galvalume base-PPGL Sheets], having tensile strength of 550 Mpa, in ridges, hips, valley gutters, drip and straight flashing cut to length & bent to shape, girth sheets fixed with aluminium self tapping screws and neoprene and EPDM washers of suitable size in roof covering / cladding / eves trim / rake trim and closure trim / valley rain water gutter/ down spouts and top rafters etc. complete all as specified.
S & F Plain Aluminium Sheeting, 0.56 mm thick, Alloy 31000 H4, as in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) including necessary fixtures complete all as specified and as directed.
M&L for Asbestos cement building board cover strips, 50mm x 5mm, with bevelled edges over joints including all mitres, etc., and fixed with screws all as specified and as directed.
M&l for two coats of latex power SBR based multi purpose polymer for water proofing and repair in composition of one part of latex SBR, four parts of water and eight parts of cement on walls and base slab of the RCC water tanks, RCC roof , etc. including necessary preparation of surfaces as per the manufacturer's instructions complete all as specified and as directed. Note: The water proofing treatment works shall be carried out by the contractor through authorised applicators of the manufacturers only.
Removing plants/ herbs grown on duct / wall portion & SWR pipes joint area for multistoried building at any storeyed cleaning with steel wire brush and rubbish and down all dirt , mud and shabby material from the SWR pipe joints , duct and wall portion complete and applied neat cement slurry / cement mortar on the leakages of SWR pipe joints / vertical stacks and applying two coats of weather proof paint with necessary safety measures i.e scaffoldings / hanging platform up to 09 (nine) floors complete all as specified and as directed.
M & L for water proofing treatment with one coat of Brush Bond RFX of M/s FOSROC of equivalent approved manufacturer on concrete / plastered surfaces including necessary preparation of surfaces complete all as specified and as directed and as per manufacturer's instructions.
M & L for PCC 1:5:10, Type E-2, using 40mm graded stone aggregate as in Sunken Floors etc complete all as specified and as directed.
M & L for 25 mm thick PCC 1:2:4, Type B-1 using 10 mm graded aggregate as in sub base/ levelling course for flooring, surface finished fair and even complete all as specified and as directed.
M & L for 100 mm thick, PCC 1:2:4, Type B-2, using 40mm graded stone aggregate as in Floors/ Hard standing etc, surface finished even and smooth with out using extra cement and spike rolling to surfaces or making impressions of expanded metal, while the concrete is green and providing 10mm thick joints duly filled with mastic filling comprising of 01 Part of heated bitumen blown grade any penetration and 3 parts of sand [all by weight] complete all as specified and as directed.
M & L for Inter Locking Paving Blocks of 80mm thick, made with M-40 Grade cement concrete using 20 mm graded stone aggregate, Hydraulically pressed of approved colour and pattern conforming to IS - 15658 set in floors complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M & L for 20-25mm thick water proof, anti-skid, shock absorbing bitumen mastic flooring, Grade-III, conforming to IS 1195-2002 and as per Petroleum and Explosives Safety Organisation (PESO) Standards, laid on top of concrete floor all as specified and as directed.
M & L for Non Skid Ceramic Tiles, Coloured, of size exceeding 0.06 Sq.m and not exceeding 0.11Sq.m, 7 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 8 mm thick [Square or Rectangular] as in vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat of 10mm thick in cement mortar 1:3 complete all as specified and as directed.
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 300 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE.
M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Floors, Treads of Steps, Window Cills, Cooking Platform etc., and the like with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabs including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: Single stone slab shall be used for entire Width and Length of Steps, Window Cills, Cooking Platform etc. and joints shall match with the flooring. The edges of treads shall be bull nosed / half rounded. The edges of the treads and landings shall also be provided with three Nos of grooves.
M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, and finishing the top surface even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:4, and finishing the top surface even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Supply only integral water proofing compound [ISI marked] of approved make.
M & L for preparing newly plastered ceiling surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for preparing newly plastered surfaces of wall, Pillasters etc. and applying three coats of white washing complete all as specified and as directed.
M & L for preparation of old decorated surfaces of walls, pillasters, etc. including brooming down or steel wire brushing and applying one coat of white wash on ceilings complete all as specified and as directed.
M & L for preparation of old decorated ceiling surfaces including brooming down or steel wire brushing and applying one coat of white wash complete all as specified and as directed.
M & L for preparing newly plastered Wall surfaces by using vaccume based sanding machine and applying two coats of Acrylic washable Distemper by using auto roller/airless sprayer, over a coat of alkali resistant primer over two or more coats of Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface complete all as specified and as directed. Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.
M & L for Complete removal of existing treatment of any description on wall surfaces by using vaccume based sanding machine, removal of nails and applying two or more coats of Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one of alkali resistant primer on wall surfaces complete all as specified and as directed. Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.
M & L for washing, rubbing down and stopping of distempered and painted surfaces of walls and applying one coat of Acrylic Washable Distemper on wall surfaces by using auto roller/ airless sprayer complete all as specified and as directed. Note:- The contractor shall carryout Distempering works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.
M & L for Two coats of Cement Based paint over a coat of Alkali Resistant Primer by using auto roller/ airless sprayer on newly plastered Walls/ ceilings, pillasters, bands, borders, soffits of chajjas and projections including necessary preparation of surfaces by using vaccume based sanding machine complete all as specified and as directed. Note:- The contractor shall carryout Cement Babsed Painting under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Cement Based Painting through their authorised applicators before commencement of the work to GE for approval.
M & L for One coat of Cement Based paint by using auto roller/ airless sprayer on old painted Walls/ ceilings, pillasters, bands, borders, soffits of chajjas and projections including necessary preparation of surfaces by using vaccume based sanding machine complete all as specified and as directed. Note:- The contractor shall carryout Cement Babsed Painting under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Cement Based Painting through their authorised applicators before commencement of the work to GE for approval.
M & L for Complete removal of existing treatment of any description on walls surfaces by using vaccume based sanding machine, removal of nails including rubbing with sand paper to obtain a smooth surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on walls complete all as specified and as directed. Note:- The contractor shall carryout Weather proof Exterior Emulsion Painting under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Weather proof Exterior Emulsion Painting through their authorised applicators before commencement of the work to GE for approval.
M & L for preparation of old painted concrete surfaces including and applying one coat of synthetic enamel paint complete all as specified and as directed.
M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
S & F CPVC Pipes 15 mm outer diameter & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, including taking down of existing unserviceable GI pipes complete all as specified and as directed.
S & F CPVC Pipes 20 mm outer diameter & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, including taking down of existing unserviceable GI pipes complete all as specified and as directed.
S & F CPVC Pipes 25 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing including taking down of existing unserviceable GI pipes complete all as specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 20 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Ball Valves 20 mm dia high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight-210gms) complete all as specified and as directed.
S & F in repairs 75mm dia outlet PVC [SWR] Floor Trap with grating including jointing with solvent cement complete all as specified and as directed. Note: The rate quoted shall be inclusive of provision of PCC 1:2:4 type B-0 to a size of 300mm x 300mm and to the required depth below the floor trap including making good the disturbed portion to match with the existing adjoining surfaces.
S & F in repairs PTMT Grating Doom, 100 mm dia [Minimum weight 25 Grams] without waste hole or with waste hole to insert waste pipe complete all as specified and directed.
S & F in repairs PTMT Grating Doom, 125 mm dia [Minimum weight 40 Grams] without waste hole or with waste hole to insert waste pipe complete all as specified and directed.
S& F in repairs brass spindles suitable for 15mm bore pillar taps of any description and type all as specified and as directed.
S& F in repairs brass spindles suitable for 15mm bore bib taps of any description and type all as specified and as directed.
S& F in repairs brass spindles suitable for 15mm bore stop valves of any description and type all as specified and as directed.
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with solvent cement/ rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with solvent cement/ rubber ring joints, fixed to walls with necessary brackets, clamps complete all as specified and as directed.
S & F 75mm bore PVC [SWR] pipes single socketed, in any length with solvent cement/ rubber ring joints, fixed to walls with necessary brackets, clamps complete all as specified and as directed.
S & F 50mm bore PVC [SWR] pipes single socketed, in any length with solvent cement/ rubber ring joints, fixed to walls with necessary brackets, clamps complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius with Access Door including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Bends of any radius with Access Door including jointing with solvent cement complete all as specified and as directed.
S & F 50 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed.
Demolition of Reinforced Cement Concrete [reinforcement cut as required to facilitate demolition] of any description and in any position not otherwise specifically provided for and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance exceeding 1.5 KM but not exceeding 5.0 KM complete all as specified and as directed.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance exceeding 1.5 km but not exceeding 5 KM complete all as specified and as directed.
Demolition of Stone Slab laid, bedded and pointed in Cement Mortar of thickness not exceeding 25 mm and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for Point Wiring for Flame Proof Fixtures / Fittings complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including ERW Steel Conduit 20 mm dia, Medium Grade, ISI Marked including all accessories on Walls / Roofs / Floors / Ceiling etc. including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / 3 Pin Socket controlled by One Flame Proof Rotary Type Switch complete all as specified.
S & F Switch Flame Proof rotary type with Termination Box in LM6, upto 16A, Single Pole, 240 Volts complete all as specified and as directed.
S & F Flame proof LED Tube Light Fitting 2 x 20 Watts, not less than 2000 Lumens output, 5700 K, with Pressure Die Cast Aluminium Housing, IP65 Protection, CMRI certified (recommended for gas/ vapour group IIA & IIIB, Zone 1 & 2), Heat resistant Toughened Glass Cover, electronic driver, all accessories internally prewired and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Flame proof LED High Bay Light fitting, 1 x 80 Watts, not less than 8000 Lumens output, 5700 K, with Pressure Die Cast Aluminium Housing, IP65 Protection, CMRI certified (recommended for gas/ vapour group IIA & IIIB, Zone 1 & 2), Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 2.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F MCCB, FP, 63 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F MCB DB, TPN, 4 Way, 415 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall including making good disturbed surfaces complete all as specified and as directed.
S & F Flame Proof MCB DB, SPN, 6 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall including making good disturbed surfaces complete all as specified and as directed.
S & F RCCB, Two Pole, 30mA, 40 Amps for Earth Leakage, Overload & Short- Circuit Protection 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, TPN, 63 Amps, 10 KA, 'C' Curve, AC, 415 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SP, 6 - 32 Amps, 10 KA, 'C' Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F Flame proof Exhaust Fan, 380 mm sweep or nearest size, 1440 RPM, Single Phase, 240 Volts, 50 Hz, Heavy Duty, Metal Body including louver shutter and all necessary fixtures complete all as specified and directed. Make: SUDHIR/ SHYAM/ BALIGA
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 6 Sq.mm PVC insulated coper conductor cable & one run of 20 mm dia PVC Conduit will be measured as one unit
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 16 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed.
M & L for Dry River Sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.
Supplying and laying un–reinforced Precast Concrete Cable Cover, Class LV, Type 1, Flat, of size 250mm x 150mm x 40mm complete all as specified and as directed.
Supplying and laying GI pipe, 40mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
M & L for Cutting Bituminous Road / Hardstanding etc. as required for Jointing / Laying Cables and Pipeline of width not exceeding 300mm and depth not exceeding 600mm and refilling after laying and making good with PCC 1:2:4, Type B1 using 20mm graded stone aggregate, 100mm thick complete all as specified and as directed.
Taking down existing LT UG cables of any description and size after disconnecting the existing connections carefully and relaying in alternate route as directed by the Engineer-in-charge including connecting up and testing complete all as specified and as directed. Note: Excavation, earthwork, sand cushioning, cable cover, etc. as required shall be measured and paid separately under relevant items of this BoQ.
Note for BoQ: Certain Addn/ Altn works catered in this BoQ such as replacement of GI pipe lines with CPVC pipes/ PVC SWR pipe lines, external Plastering, external finishes such as cement based painting/ weather proof extrior emulsion painting, water proofing treatment to existing structures, etc. shall be required to be carried out up to G+9 Storey height and the bidders are deemed to be visited the sites and get acquainted themslves the site conditions and the rates quoted for the relevant items are deemed to be including providing double scaffolding and safety measures as required and removal of the same on completion all as specified and as directed. Nothing extra shall be paid to the contractor on this account.
M/s Sai Venkata Durga Constructions
P SRINIVASA RAO
Mahamaruti Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .