Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.6 LAccepted-Finance 13TH FLOOR DN18 SALTEE TECH PARK SECTOR V SALT LAKE BIDHAN NAGAR KOLKATA 700091 | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L1 | Accepted-Finance Complying tender criteria | |
| 2 | L2₹65.0 L+₹43,184 (0.67%)Accepted-Finance 101 BLOCK QP MAURYA ENCLAVE PITAM PURA NORTH WEST DELHI DELHI 110088 | NORTH DELHI | DELHI | 110088 | L2 | Accepted-Finance Complying tender criteria | |
| 3 | L3₹67.0 L+₹2.4 L (3.77%)Accepted-Finance B 4 KALKA GARHI HANS PLAZA AMBEDKAR ROAD VILLAGE TOWN GHAZIABAD CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201001 INDIA | GHAZIABAD | UTTAR PRADESH | 201001 | L3 | Accepted-Finance Complying tender criteria | |
| 4 | L4₹72.9 L+₹8.3 L (12.9%)Accepted-Finance | L4 | Accepted-Finance Complying tender criteria | |
| 5 | L5₹79.4 L+₹14.8 L (23.0%)Accepted-Finance III 246 MANIYATTU BUILDING KURUPPAMPADY P O RAYAMANGALAM ERNAKULAM KERALA 683545 INDIA | ERNAKULAM | KERALA | 683545 | L5 | Accepted-Finance Complying tender criteria |
| Sl No | Description | Qty | Unit | R Pandurangam and Sons L8 | LIGHTING TECHNOLOGIES INDIA PVT. LTD. L10 | HARITA INDUSTRIES L9 | Bajaj Electricals Ltd L1 | CANDELA ENGINEERING CORPORATION L5 | C R ELECTRICALS L7 | VISHAL TECHNOPOWER PVT. LTD. L3 | A GOVERDHAN L6 | SYNERGY LIGHTING SOLUTIONS L2 | ARITRON SERVICES PRIVATE LIMITED L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing & commissioning (SITC) of 1000W SMD LED Floodlight fixture with minimum System efficacy of 130 lm/W (130000 lumens). Luminaire shall be made up of LM6/ADC12 Alloy, non-corrosive, pure polyester power coated die cast Aluminium housing with PC lens. Luminaire should be of dimension 744mm x 368mm x 120mm height ± 10mm height and the approximate weight should be within the 28.0Kg ± 0.5Kg. Luminaire should be with 15°, 30° and 60° beam angle option. Luminaire should be made of four individual modules of maximum 250W each. All external hardware must be of SS304 grade. LM 80-08 compliant LEDs of EMC/ceramic package of wattage of 1W-3W from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul/GE should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Maximum LENS dome top temperature shall be less than 95°C at 45°C ambient temperature. Luminaire shall be with IP66 and IK08 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K, CRI of Minimum 70 and SDCM < 5. MCPCB with Aluminium core and copper thickness of 35 micron to be used for LED mounting. LED Driver shall be silicone potted, Integrated type, Isolated, Constant Current with range 140-280V AC. Driver Efficiency > 85% & 5 KV internal surge protection with additional 10KV SPD, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. LED Driver must have short circuit, open circuit, Auto cut-off protection for low and high input voltage. Individual drivers should be provided with individual modules along with ventilated enclosure to hide the wirings. Driver must be with Aluminium casing. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. Lights should be of 5 Years warranty.
Installation on 20 meter high mast of fixed height pole & head frame, with required elevated safe working platform of desired height with complete terminations and all required accessories.
Similar to Make: Wipro, Model: Olympus Pro Floodlight, LF46-123-015-57-FF | 60 | Each | 63,000 ₹37,80,000 | 67,024 ₹40,21,440 | 69,000 ₹41,40,000 | 44,529 ₹26,71,740 | 58,500 ₹35,10,000 | 56,600 ₹33,96,000 | 44,934.4 ₹26,96,064 | 70,000 ₹42,00,000 | 44,000 ₹26,40,000 Lowest | 45,430 ₹27,25,800 |
| 2.00 | Supply, Installation, Testing & commissioning (SITC) of 1000W SMD LED Floodlight fixture with minimum System efficacy of 130 lm/W (130000 lumens). Luminaire shall be made up of LM6/ADC12 Alloy, non-corrosive, pure polyester power coated die cast Aluminium housing with PC lens. Luminaire should be of dimension 744mm x 368mm x 120mm height ± 10mm height and the approximate weight should be within the 28.0Kg ± 0.5Kg. Luminaire should be with 15°, 30° and 60° beam angle option. Luminaire should be made of four individual modules of maximum 250W each. All external hardware must be of SS304 grade. LM 80-08 compliant LEDs of EMC/ceramic package of wattage of 1W-3W from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul/GE should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Maximum LENS dome top temperature shall be less than 95°C at 45°C ambient temperature. Luminaire shall be with IP66 and IK08 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K, CRI of Minimum 70 and SDCM < 5. MCPCB with Aluminium core and copper thickness of 35 micron to be used for LED mounting. LED Driver shall be silicone potted, Integrated type, Isolated, Constant Current with range 140-280V AC. Driver Efficiency > 85% & 5 KV internal surge protection with additional 10KV SPD, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. LED Driver must have short circuit, open circuit, Auto cut-off protection for low and high input voltage. Individual drivers should be provided with individual modules along with ventilated enclosure to hide the wirings. Driver must be with Aluminium casing. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. Lights should be of 5 Years warranty.
Installation on 20 meter high mast of fixed height pole & head frame, with required elevated safe working platform of desired height with complete terminations and all required accessories.
Similar to Make: Wipro, Model: Olympus Pro Floodlight, LF46-123-030-57-FF | 4 | Each | 69,500 ₹2,78,000 | 67,024.01 ₹2,68,096.04 | 69,000 ₹2,76,000 | 44,529 ₹1,78,116 | 58,500 ₹2,34,000 | 56,600 ₹2,26,400 | 44,934.4 ₹1,79,737.6 | 70,000 ₹2,80,000 | 44,000 ₹1,76,000 Lowest | 45,430 ₹1,81,720 |
| 3.00 | Supply, Installation, Testing and Commisioning (SITC) of 20 M (17M + HF 3M) LIGHTING STADIUM MAST FABRICATED PART AS PER DIMENSION :TOP DIAMETER -200 mm, BOTTOM DIAMETER 610 mm, SECTION - 3(SECTION LENGTH - 8900 mm /8900 mm/3000 mm) PLATE THICKNESS - 4,4,5 mm.BASE PLATE - 840 mm x 30 mm,PCD - 740 mm, With Double dome aviation lamp, Lighntning Arrestor and also Includes the follwing material and works with all required accessories as per the directiond of Engineer-In-Charge.
a) Supply of Foundation BOLT M30 x 850 mm x 16 Nos with Template and Anchor Plate
b) Supply, handling and Installation of HEAD FRAME with Maintenance cage and Light Fixtures Mounting Platform, incuding all required accessories.
c) SUPPLY OF ACCESSORIES SET
d) Supply and Installation of Man Riding Unit with all required accessories.
e) The scope of work Includes SITC of the 20M height Lighting Stadium Mast including transportation to site, handling at site and loading shifting to the location, installation in all respectes with required Crane/Hydra.
f) Inspection of the safe installation with authorised body or licensed agency and submission of safety certification included in the work.
g) Laying of wire from flood lights at top of the mast till feeder pillar box at bottom, excluding the wire.
h) SITC of Oudoor Feeder Pillar Unit IP 55 rated, power supply to the Stadium Lighting Mast of not less than rated 40KW. I/P 63A 4P MCB, 4 Way Terminal for input and 16 output terminal connections with 6-10A SP MCB for each output with 3 phase uniform loading, Digital Timer, Toggle switch of 6A for Auto Manual Selection, Single Pole MCBs, Overload Relay of 2.5A - 4A, Contactor of Motor Control, 4/3way terminal for motor, Push Switch for Motor operation, Rotary Switch for FWD/REV selection, Pendent Box for Motor Operation. | 4 | Each | 6,75,000 ₹27,00,000 | 7,65,584 ₹30,62,336 | 7,21,000 ₹28,84,000 | 4,34,216 ₹17,36,864 Lowest | 7,67,000 ₹30,68,000 | 7,60,000 ₹30,40,000 | 5,76,164.5 ₹23,04,658 | 5,97,500 ₹23,90,000 | 6,20,000 ₹24,80,000 | 6,85,610.09 ₹27,42,440.36 |
| 4.00 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | 8 | Set | 10,000 ₹80,000 | 14,750 ₹1,18,000 | 9,600 ₹76,800 | 13,890 ₹1,11,120 | 12,000 ₹96,000 | 15,000 ₹1,20,000 | 17,700 ₹1,41,600 | 17,750 ₹1,42,000 | 3,000 ₹24,000 Lowest | 11,682 ₹93,456 |
| 5.00 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. | 192 | Metre | 100 ₹19,200 | 59 ₹11,328 | 55 ₹10,560 | 28 ₹5,376 | 25 ₹4,800 Lowest | 35 ₹6,720 | 56.46 ₹10,840.32 | 50 ₹9,600 | 30 ₹5,760 | 305.03 ₹58,565.76 |
| 6.00 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) | 80 | Metre | 225 ₹18,000 | 159.3 ₹12,744 | 150 ₹12,000 Lowest | 201 ₹16,080 | 150 ₹12,000 Lowest | 200 ₹16,000 | 213.12 ₹17,049.6 | 150 ₹12,000 Lowest | 150 ₹12,000 Lowest | 240.13 ₹19,210.4 |
| 7.00Supply, loading, transportation, unloading at site, storage st site, shifting from storage place to site of following size of stranded Copper conductor, XLPE Insulated, PVC tape/PVC Extruded Innersheathed for Multicore Cables, Unarmoured, extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988 with upto date Amendments and as per specifications. | |||||||||||||
| 7.10 | 3C x 1.5 sqmm | 1,800 | Metre | 130 ₹2,34,000 | 106.2 ₹1,91,160 | 135 ₹2,43,000 | 122 ₹2,19,600 | 80 ₹1,44,000 Lowest | 110 ₹1,98,000 | 92.37 ₹1,66,266 | 125 ₹2,25,000 | 125 ₹2,25,000 | 96.05 ₹1,72,890 |
| 8.00Supply, loading, transportation, unloading at site, storage st site, shifting from storage place to site of following size of XLPE Insulated PVC Sheathed Stranded Aluminium Conductor armoured power cable of 1.1 KV grade conforming to IS 7098 (Part 1) 1988 with upto date Amendments and as per specifications. | |||||||||||||
| 8.10 | 4C x 35 sqmm | 550 | Metre | 370 ₹2,03,500 | 312.7 ₹1,71,985 | 575 ₹3,16,250 | 404 ₹2,22,200 | 350 ₹1,92,500 | 312 ₹1,71,600 | 312.15 ₹1,71,682.5 | 350 ₹1,92,500 | 450 ₹2,47,500 | 266.09 ₹1,46,349.5 Lowest |
Tender Value
₹1.0 Cr
EMD Value
₹2.0 L
Closing Date
7 Aug 2025, 3:00 pmClosed
Executive Engineer-Electrical
CMD Office, IIT Hyderabad campus, Kandi-502284, Sangareddy, Telangana
Supply, Installation, Testing and Commissioning (SITC) for Sports Lighting for New Hockey Ground and associated electrical enabling works at IIT Hyderabad, Kandi
2025_IITH_869272_1
IITH/CMD/ELE/NIT/2025-26/01
Open Tender
Electrical Works
Item Rate
90 days
IIT Hyderabad campus, Kandi
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹2.0 L
11 Sept 2025
17 Jul 2025
8 Aug 2025
17 Jul 2025
7 Aug 2025
17 Jul 2025
Amount
Supply, Installation, Testing & commissioning (SITC) of 1000W SMD LED Floodlight fixture with minimum System efficacy of 130 lm/W (130000 lumens). Luminaire shall be made up of LM6/ADC12 Alloy, non-corrosive, pure polyester power coated die cast Aluminium housing with PC lens. Luminaire should be of dimension 744mm x 368mm x 120mm height ± 10mm height and the approximate weight should be within the 28.0Kg ± 0.5Kg. Luminaire should be with 15°, 30° and 60° beam angle option. Luminaire should be made of four individual modules of maximum 250W each. All external hardware must be of SS304 grade. LM 80-08 compliant LEDs of EMC/ceramic package of wattage of 1W-3W from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul/GE should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Maximum LENS dome top temperature shall be less than 95°C at 45°C ambient temperature. Luminaire shall be with IP66 and IK08 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K, CRI of Minimum 70 and SDCM < 5. MCPCB with Aluminium core and copper thickness of 35 micron to be used for LED mounting. LED Driver shall be silicone potted, Integrated type, Isolated, Constant Current with range 140-280V AC. Driver Efficiency > 85% & 5 KV internal surge protection with additional 10KV SPD, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. LED Driver must have short circuit, open circuit, Auto cut-off protection for low and high input voltage. Individual drivers should be provided with individual modules along with ventilated enclosure to hide the wirings. Driver must be with Aluminium casing. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. Lights should be of 5 Years warranty. Installation on 20 meter high mast of fixed height pole & head frame, with required elevated safe working platform of desired height with complete terminations and all required accessories. Similar to Make: Wipro, Model: Olympus Pro Floodlight, LF46-123-015-57-FF
Supply, Installation, Testing & commissioning (SITC) of 1000W SMD LED Floodlight fixture with minimum System efficacy of 130 lm/W (130000 lumens). Luminaire shall be made up of LM6/ADC12 Alloy, non-corrosive, pure polyester power coated die cast Aluminium housing with PC lens. Luminaire should be of dimension 744mm x 368mm x 120mm height ± 10mm height and the approximate weight should be within the 28.0Kg ± 0.5Kg. Luminaire should be with 15°, 30° and 60° beam angle option. Luminaire should be made of four individual modules of maximum 250W each. All external hardware must be of SS304 grade. LM 80-08 compliant LEDs of EMC/ceramic package of wattage of 1W-3W from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul/GE should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Maximum LENS dome top temperature shall be less than 95°C at 45°C ambient temperature. Luminaire shall be with IP66 and IK08 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K, CRI of Minimum 70 and SDCM < 5. MCPCB with Aluminium core and copper thickness of 35 micron to be used for LED mounting. LED Driver shall be silicone potted, Integrated type, Isolated, Constant Current with range 140-280V AC. Driver Efficiency > 85% & 5 KV internal surge protection with additional 10KV SPD, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. LED Driver must have short circuit, open circuit, Auto cut-off protection for low and high input voltage. Individual drivers should be provided with individual modules along with ventilated enclosure to hide the wirings. Driver must be with Aluminium casing. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. Lights should be of 5 Years warranty. Installation on 20 meter high mast of fixed height pole & head frame, with required elevated safe working platform of desired height with complete terminations and all required accessories. Similar to Make: Wipro, Model: Olympus Pro Floodlight, LF46-123-030-57-FF
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supply, loading, transportation, unloading at site, storage st site, shifting from storage place to site of following size of stranded Copper conductor, XLPE Insulated, PVC tape/PVC Extruded Innersheathed for Multicore Cables, Unarmoured, extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988 with upto date Amendments and as per specifications.
3C x 1.5 sqmm
Supply, loading, transportation, unloading at site, storage st site, shifting from storage place to site of following size of XLPE Insulated PVC Sheathed Stranded Aluminium Conductor armoured power cable of 1.1 KV grade conforming to IS 7098 (Part 1) 1988 with upto date Amendments and as per specifications.
4C x 35 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 35 sq. mm (32mm)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
150 mm dia
CIVIL WORK: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Columns, piers, abutments, pillars, posts and struts
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stoneaggregate 40 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
All works upto plinth level
6 mm cement plaster of mix :
1:3 (1 cement : 3 fine sand)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and atering, lead up to 50 and for all lift.
Total Excavated area
SYNERGY LIGHTING SOLUTIONS (BID ID -3262356)
VISHAL TECHNOPOWER PVT. LTD. (BID ID -3262245)
ARITRON SERVICES PRIVATE LIMITED (BID ID -3259301)
CANDELA ENGINEERING CORPORATION (BID ID -3262442)
A GOVERDHAN (BID ID -3261223)
C R ELECTRICALS (BID ID -3262421)
R Pandurangam and Sons (BID ID -3251421)
HARITA INDUSTRIES (BID ID -3258227)
LIGHTING TECHNOLOGIES INDIA PVT. LTD. (BID ID -3252134)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .