Loading…
Loading…
Tender Value
₹2.5 Cr
EMD Value
₹5.0 L
Closing Date
15 Jun 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
WORKS
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway
Note for Technical Eligibility Criteria: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Definition of Single Similar Work: "Any signal interlocking works involving EI or RRI or PI or IBS or IBH or LC gate or yard modification or UFSBI or Track circuit (AFTC or DC TC) or Axle Counter (SSDAC or MSDAC or HA- SSDAC) or Automatic signalling." ( Sl No.14 of PCSTE/SR letter No./SG.191/Similar nature of work dated 25.02.2026).
27 conditions · 3 needing a document upload
All the tenderers/Contractors have to deposit full Bid Security and tender document cost as stipulated for the tender, through online modes as permitted in IREPS application through multiple banks net banking, debit and credit cards . All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded failing which offer will be summarily rejected.
Until a formal agreement is prepared and executed, acceptance of this tender shall constitute a binding contract between us subject to modifications, as may be mutually agreed to between us and indicated in the letter of acceptance of my/our offer for this work.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract for works 2022, with all correction slips up-to-date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions/Specifications, Schedule of Rates with all correction slips up to date for the present contract
I/We offer to do the work for DRM/S&T/TVC, at the rates quoted in the attached schedule and hereby bind myself/ourselves to complete the work in all respects within the period of completion stipulated in the tender document, from the date of issue of letter of acceptance of the tender. The amount as stipulated in the tender document is herewith forwarded as Bid Security. Full value of the bid security shall stand forfeited without prejudice to any other right or remedies in case my/our Tender is accepted and if : (a) I/We do not execute the contract documents as stipulated in performance guarantee clause of GCC for works 2022 as detailed in general instructions. (b) I/We do not commence the work within seven days after receipt of orders to that effect.
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
Manual submission of Bid Security and cost of tender form cannot be entertained/Considered and hence no need of uploading the scanned copy of financial instruments
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association Board resolution, failing which tender shall be summarily rejected. The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate.
INSTRUCTIONS TO TENDERERS
The tenderer shall thoroughly go through the entire tender documents and strictly adhere the instructions and directions given at different pages.
Tender Document Cost for this work is Nil.
Unreleased Bid Security, if any, held with the Railway Administration, shall not be adjusted towards the Bid security to be remitted.
If the Tenderer(s) deliberately give(s) wrong information/ incorrect documents in his/their tender or create circumstances for the acceptance of his/their tender, the Railway reserves the right to reject such tender at any stage. The entire Bid Security and any other dues available with Railway against that contract will be forfeited. Action will be taken to suspend the business with the tenderer for a period of two years. In addition, Administration reserves the right to prosecute under suitable law.
All terms and conditions in the tender documents are binding on the Tenderers.
Railways reserves the right to accept or reject any or all the tenders and to award the work in whole or in part without assigning the reason for any such action.
The Tenderers are advised to visit the site of work in their own interest and acquaint themselves with the site conditions and expected quantum of work and assess all the site specific difficulties to be experienced while executing the same and the rate shall be arrived duly considering all the facts above and quoted in the tender. Any representation at a later date specifying the site difficulties shall not be considered.
The bidder has to fill in his quoted rate against each item in the Bid rate / Unit rate column. If the bidding unit is Above/ Below/ Par, the bidder can select the %Above, %Below or %At Par option from the drop down list in the same column. If the bidding rate is Rs. or Rs./ unit, the bidder has to quote his rate for the item group or individual item accordingly
All the bidders/tenders should ensure that they are GST compliant and their quoted tax structure/rates are as per GST Law
In case of any wrong information submitted by tenderer, the contract shall be terminated, Bid security, Performance Guarantee(PG) and Security Deposit(SD) of contract forfeited and agency barred for doing business on entire Indian Railways for 2(Two) years
Provision of S&T arrangements in connection with provision of Track Machine Siding at KOLLAM & KAYANKULAM stations and proposed extension of shunting neck at THRISSUR stations of TVC division.
TVC-SNT-SIG-26-27-01
TVC-SNT-SIG-26-27-01
Open
Works - General
9 Months
Thiruvananthapuram, Kerala
₹0
₹5.0 L
15 Jun 2026
22 May 2026
1 Jun 2026
100 items across 1 schedule · ₹2,31,72,544.52 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | "Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As- made circuit diagrams also as mentioned above" | Sheet 160.00 | — | 382.12 | 61,139.2 |
| 2 | Supply of indicative type Surge Protection Device as per RDSO Spec. No. SPN/165/ 2023, Version 4.0 Amdt.1 or latest (Lightning and Transient surge protection for power line). The system shall have stage1 (class B) and stage 2 (class C) type against Lightning electromagnetic Impulse configuration. The protection of Type 1 and 2 against Lightning electromagnetic Impulse (LEMP) and other high surge, shall be provided at the incoming of the power line at the stations, LC gates before the power equipment's as per the instructions of Engineer in-charge at site. Supply of surge protection with Potential free contacts shall be of approved make like OBO, DEHN, PHOENIX, LPT or better make. All other miscellaneous materials required for the work shall be supplied by the contractor. (as per Technical Specification enclosed) | Numbers 3.00 | — | 22,756.39 | 68,269.17 |
| 3 | Supply and Provision of indicative type Class D Surge Protection Device for 24V DC/48V DC (spark gap type), with Potential Free contacts and installed as per the instructions of the Engineer i n charge a t s i t e ( OBO, DEHN, PHOENIX, L P I , Z O T U P , H A K E L or better m a k e ) . A l l o t h e r miscellaneous materials required for installation shall b e supplied by the contractor. | Numbers 5.00 | — | 6,328.8 | 31,644 |
| 4 | Supply and Provision of Earthing as per RDSO Specification RDSO/SPN/197/2008 or latest (as per Technical Specification enclosed) | Numbers 7.00 | — | 28,118.51 | 1,96,829.57 |
| 5 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 35.00 | — | 1,707.55 | 59,764.25 |
| 6 | "Installation of 230V Class B & Class C Surge P r o t e c t i o n D e v i c e . T h i s includes t r a n s p o r t a t i o n o f m a t e r i a l s t o site. Installation t o b e carried o u t a s p e r the direction o f R ailw a y Engineer. Necessary copper wire for Power Wiring and connecting t h e e a r t h t o b e supplied a s p a r t o f the schedule. All other miscellaneous materials required for installation shall b e supplied by the contractor." | Numbers 3.00 | — | 9,752.74 | 29,258.22 |
| 7 | Supply of DC-DC Converter of Capacity 110V DC/24-40V, 10A as per RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest | Numbers 6.00 | — | 21,381.6 | 1,28,289.6 |
| 8 | Supply o f L o w maintenance secondary cells o f t h e following capacities w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document.b)Supply o f Secondary cells - 2V- 80AH capacity | Numbers 35.00 | — | 3,379.2 | 1,18,272 |
| 9 | Supply of track feed battery charger IRS:S 89-2013 | Numbers 14.00 | — | 4,375.25 | 61,253.5 |
| 10 | Supply of 'B type choke IRS:S 65-83 | Numbers 17.00 | — | 2,855.6 | 48,545.2 |
| 11 | Installation of power equipments like battery c h a r g e r s , t r a n s f o r m e r s , transformer rectifiers, invertors, DC-DC convertors etc., in the apparatus cases and wiring the same u s i n g w i r e P V C 7 /1 .4 m m a n d 3/0.75mm copper a s per the approved wiring diagram and painting of particulars in the inside of the doors of the apparatus cases. The work also includes provision o f protective arrangements in bare terminals carrying high voltages. (Supply of power equipments is not included in this schedule).[Wire PVC 7/1.4mm and 3/0.75mm copper, protective arrangements, paint and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Numbers 6.00 | — | 1,708.01 | 10,248.06 |
| 12 | Supply of 24 Core x 1.5 Sq.mm PVC insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 | Metre 23500.00 | — | 388.15 | 91,21,525 |
| 13 | S u p p l y o f 1 2 Cx1 .5 S Q M M P V C insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 | Metre 8500.00 | — | 215.92 | 18,35,320 |
| 14 | " S u p p l y o f 2 x 2 5 s q m m P V C insulated Armoured, unscreened underground Railway Signalling Aluminium cable a s p e r I R S : S- 63/2014 REV.4" | Metre 9500.00 | — | 93.01 | 8,83,595 |
| 15 | " S u p p l y o f 2 x 2 . 5 s q . m m P V C insulated Armoured, unscreened, underground Railway S i g n a l l i n g C o p p e r c a b l e a s p e r spec IRS.S.63/2014(Rev.4.0) or latest" | Metre 2000.00 | — | 98.76 | 1,97,520 |
| 16 | Supply o f Underground jelly filled 6 QUAD, 0.9MM D i a a s p e r spe c IRS:TC 30-05 with amd 5 or latest | Metre 11500.00 | — | 301.05 | 34,62,075 |
| 17 | Supply o f 2 4 Fibre armoured O F C cable as p e r R D S O S p e c i fi c a t i o n RDSO/SPN/TC/ 110/2020 Rev. 0 or latest | Metre 2000.00 | — | 95.23 | 1,90,460 |
| 18 | S u p p l y o f Polythene Insulated Polythene Sheathed armoured J e l l y Fi l l e d Telephone Cable with Poly-AL Moisture Barrier, 10 Pairs, 0.63 MM Conductor Diameter as per RDSOSpecification N o . IRS:TC-41/97 with amendment 1 or latest | Metre 500.00 | — | 123.9 | 61,950 |
| 19 | Supply a n d provision o f normal joint using Thermo shrink jointing k i t (RDSO specs No TC/77/2012 ( Rev.3) with amendment No.1&2 o r latest.& jointing k i t t o be inspected by RDSO) for 4/6 quad cable normal joint. The work includes excavation of joint p i t o f size 1mX1.5mX1.5m and closing t h e same after completion o f cable joint a s p e r the instruction of Railway representative at site. | Numbers 28.00 | — | 4,628.91 | 1,29,609.48 |
| 20 | S u p p l y a n d provision o f derivation joint complete f o r 6 Q u a d c a b l e s using thermoshrink jointing kit for LC's/stations | Numbers 4.00 | — | 4,901.27 | 19,605.08 |
| 21 | S u p p l y a n d installation o f 2 4 Fi b r e Joint enclosure f o r armoured optical fi b r e cable c o n f o r m i n g t o RDSO spec.RDSO/SPN/TC/68/2014 rev2.0 or latest | Numbers 4.00 | — | 13,647.37 | 54,589.48 |
| 22 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. The lettering on the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions o f Railway representative at site.) as per drawing enclosed | Numbers 125.00 | — | 262.65 | 32,831.25 |
| 23 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying o f cables i s n o t included i n this schedule) | Metre 2600.00 | — | 64.1 | 1,66,660 |
| 24 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth o f 0 . 6 m t o accommodate t h e additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating i t a s p e r t h e instructions of Railway Representatives a t site. (Laying of cables is not included in this schedule). | Metre 510.00 | — | 314.41 | 1,60,349.1 |
| 25 | Excavation of trench along route of existing c a b l e d u c t , o p e n i n g t h e s l a b s to a c c o m m o d a t e a d d i t i o n a l c a b l e laying, REPOSITIONING the slabs removed after the cables are laid and PLASTERING with cement mortar, and refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives a t site. (Laying of c a b l e s i s n o t included i n t h i s schedule.) [Cement,M Sand and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Metre 500.00 | — | 161.92 | 80,960 |
| 26 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ramming a n d consolidating i t a s p e r the instructions of Railway representative at site a f t e r l a y i n g o f D W C / RC C p i p e s . During excavation o f trench, i t h a s t o b e ensured that the excavated soil does not mix with the ballast available. T h e depth o f 1 m trench shall be from the bottom of sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre 192.00 | — | 385.45 | 74,006.4 |
| 27 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench b y r a m m i n g a n d consolidating i t and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f D W C / R C C p i p e s with couplers/collars is not included in this schedule). | Metre 68.00 | — | 501.03 | 34,070.04 |
| 28 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre 140.00 | — | 208.54 | 29,195.6 |
| 29 | Provision o f G I p i p e s (50/100mm d i a ) for cable laying in hard rocky area with off sets a t b o t h e n d s d u l y supported b y concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, and all other miscellaneous materials required for t h e w o r k s h a l l be supplied by the Contractor]. | Metre 200.00 | — | 182.87 | 36,574 |
| 30 | L a y i n g o f signaling/power/ telecommunication cables a s per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables is not included in this schedule). | Metre 21500.00 | — | 18.18 | 3,90,870 |
| 31 | Placing of one row of country bricks of size approximately 220mm x 100mm x 60mm breadth wise horizontally above the cables in 0.3m width trench.[Country bricks of size 220mm x 100mm x60 mm (approximately) shall be supplied by the Contractor]. | Metre 2600.00 | — | 62.99 | 1,63,774 |
| 32 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cable s, a n d consolidating t h e t r e n c h by ramming and levelling." | Metre 2600.00 | — | 15.4 | 40,040 |
| 33 | "Digging of pit to a depth of 800mm of size 3 0 0 m m X 3 0 0 m m , c a s t i n g o f concrete foundation o f size 300mmX300mmX300mm and Placing of RCC cable markers on top of t h e foundation a n d refilling t h e p i t and consolidating i t b y ramming. T h e cable markers shall be provided at an interval of 20 M t r s . w i t h i n statio n l i m i t s a n d 5 0 Mtrs. outside station limits throughout t h e cable route, diversions and also at every track/road crossing." | Numbers 125.00 | — | 123.35 | 15,418.75 |
| 34 | Excavation o f c a b l e c o i l p i t t o a s i z e of 1.5mx1.5m a n d d e p t h a s instructed by Railway representative at site, for coiling the cables i n r e a r o f relay rooms/ A F TC huts, apparatus c a s e s e t c . T h e w o r k includes coiling t h e underground cables a n d placing closely o n e layer o f country bricks o f size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks o f size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum 10.00 | — | 949.05 | 9,490.5 |
| 35 | B l o w i n g / D r a w i n g o f O F C cable/Power cable/Signalling c a b l e i n s i d e permanently solid lubricated HDPE Pipe already laid. This work includes necessary duc t integrity test for solid lubricated HDPE pipe. ( This includes Transportation o f materials from nominated stores to site) | Metre 1000.00 | — | 23.43 | 23,430 |
| 36 | Supply o f subsidiary Signal Aspect - Shunt L E D a s p e r R D S O Specification S P E C I F I C AT I O N N O . RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers 26.00 | — | 5,740.7 | 1,49,258.2 |
| 37 | M a n u f a c t u r e a n d s u p p l y o f Enameled Number plates as per drawing No.TY/08/2008 with fixing arrangements and fixing them on the existing Signals as per the instructions of Railway representative at site.[Enameled number plates with fixing arrangements with b o l t s a n d n u t s s h a l l be supplied by the Contractor]. | Numbers 11.00 | — | 305.25 | 3,357.75 |
| 38 | Supply of Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall with necessary inspection as p e r s p e c i fi c a t i o n / drawing/ description enclosed in this document. a)Supply of colour l i g h t S i g n a l p o l e 4 . 6 m tall and 140 mm dia(Galvanised) | Numbers 2.00 | — | 5,841 | 11,682 |
| 39 | Supply of surface base to suit CLS Signal pole 140mm dia with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers 2.00 | — | 6,814.5 | 13,629 |
| 40 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary inspection a s p e r specification/ drawing/ description e n c l o s e d i n this document. a)Supply o f ladder with platform (4.6m) for CLS(Galvanised) | Numbers 2.00 | — | 5,698 | 11,396 |
| 41 | S u p p l y o f G r o u n d t y p e s h u n t s i g n a l - complete with surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers 2.00 | — | 7,463.5 | 14,927 |
| 42 | Supply of KLCR relays 24V, ACI (Supply of Key Lock Checking Relay (KLCR) with one number K-50 neutral Relay to work on 24V DC non AC immunized a s p e r specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt- 1 or latest (with one extra ward plate and with case) contact configuration-4F/4B and as per IRS:S-23, IRS:S@58"44@ IRS:46 or latest. | Numbers 22.00 | — | 10,722.72 | 2,35,899.84 |
| 43 | Supply of Relay, Non-AC Immune, plug-in type , Style 'QN1',DC neutral line, 50V, 8F.8B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34 & IRS:S 23 or latest. The interlocking code for this unit shall be ABDEF. | Numbers 54.00 | — | 4,484 | 2,42,136 |
| 44 | Supply of Relay, AC Immune, plug-in-type, Style 'QNA1', DC Neutral line, 24V, 8F.8B contacts, front and back contacts metal to carbon, with plug board, retaining clip and connectors confirming to BRS:931A, IRS:S 60, IRS:S 34 and IRS:S 23 or latest. The interlocking code for this unit shall be ABDGH. | Numbers 158.00 | — | 4,639.03 | 7,32,966.74 |
| 45 | Supply of lamp proving relays(QECX-61) for a)LED aspects with plug boards, connectors and retaining clips with necessary inspection as per specification/ | Numbers 40.00 | — | 5,901.5 | 2,36,060 |
| 46 | Supply of QBCA1 - heavy duty contact relays w i t h necessary inspection a s per specification/ | Numbers 11.00 | — | 6,613.75 | 72,751.25 |
| 47 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 1 6 / 0 . 2 m m c o p p e r , P h y n o l i c synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1 9 9 5 - Ty p e F 5 , f o r fi x i n g resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set 2.00 | — | 4,945.51 | 9,891.02 |
| 48 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 1 6 / 0 . 2 m m c o p p e r , P h y n o l i c synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1 9 9 5 - Ty p e F 5 , f o r fi x i n g resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. b)Wiring o f Signal/ Point/ L C control circuit (up to 8 relays/plug in type) | Set 5.00 | — | 8,786.26 | 43,931.3 |
| 49 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 1 6 / 0 . 2 m m c o p p e r , P h y n o l i c synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1 9 9 5 - Ty p e F 5 , f o r fi x i n g resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. c)Wiring o f Signal/ Point/ L C control circuit (up to 12 relays/plug in type) | Set 3.00 | — | 11,355.02 | 34,065.06 |
| 50 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 1 6 / 0 . 2 m m c o p p e r , P h y n o l i c synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1 9 9 5 - Ty p e F 5 , f o r fi x i n g resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. d)Wiring o f Signal/ Point/ L C control circuit (up to 20 relays/Plug in type) | Set 5.00 | — | 13,597.41 | 67,987.05 |
| 51 | Supply o f Q TA 2 - t r a c k r e l a y s w i t h plug boards, connectors a n d retaining clips with necessary inspection as per specification | Numbers 19.00 | — | 4,070 | 77,330 |
| 52 | S u p p l y o f Q S PA 1 t y p e r e l a y s w i t h plug boards, connectors a n d retaining clips with necessary inspection a s per specification/drawing/ | Numbers 19.00 | — | 7,139 | 1,35,641 |
| 53 | Supply of 'A' type foundation made of cast iron as per Drg No.CWM.00902, and as per drawing. | Numbers 12.00 | — | 8,978.88 | 1,07,746.56 |
| 54 | Fabrication and Supply of box suitable for 4 Nos of KLCRs | Numbers 7.00 | — | 15,009.6 | 1,05,067.2 |
| 55 | Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood c a b l e clamps a n d base planks, termination o f cables, provision of ND type f u s e s o f required capacities, provision of copper bus bar for supply terminals, wiring, provision o f termination particulars diagram board using plywood of thickness 1 2 m m - teakwood finish o f size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic s h e e t o f t h ic k n e s s 3mm wherever required. T h e termination and cable core particulars shall be painted on the PVC/ nylon sleeves. T h e work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 60mm centers and PBT Fuse blocks i s not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper b u s bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm f o r base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit 452.00 | — | 167.99 | 75,931.48 |
| 56 | Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood c a b l e clamps a n d base planks, termination o f cables, provision of ND type f u s e s o f required capacities, provision of copper bus bar for supply terminals, wiring, provision o f termination particulars diagram board using plywood of thickness 1 2 m m - teakwood finish o f size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic s h e e t o f t h ic k n e s s 3mm wherever required. T h e termination and cable core particulars shall be painted on the PVC/ nylon sleeves. T h e work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 60mm centers and PBT Fuse blocks i s not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper b u s bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm f o r base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. b)Termination u s i n g PBT fuse block in cable termination rack (Per Unit = Per Fuse Block) | Per Unit 50.00 | — | 201.27 | 10,063.5 |
| 57 | Fixing of plug boards, 50 way terminal blocks with 2BA terminals, a n d wiring of relays as per the approved circuit diagram using wire P V C 1 6 / 0 . 2 m m c o p p e r . Suitable wire supporting tray with cover made of PVC shall be provided horizontally and vertically in the relay racks.. While running the wires on the aluminium ladder proper care shall be taken t o provide s m o o t h materials like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes wiring o f contacts f o r data logger and terminating them in tag blocks, provision of relay index board.(Supply o f relays, plug boards, connectors and retaining clips i s not c o v e r e d i n this schedule). [Wire PVC 16/0.2mm copper, tag blocks, 2BA terminals, h a r d w o o d p l a n k o f size 600mmx 900mmx25mm w i t h decolum finish, MS a n g l e s o f size 25mmX25mmX6mm, relay fixing bolts and nuts, teakwood plank 25mm thick for fixing resistors a n d condensers, p h y n o l i c sheet 6mm t h i c k o f size 1200mmX1800mm with aluminium grooved channel frame for relay index board, paints, soldering materials, bunching thread, wire w o u n d resistance, condenser, wire supporting tra y w ith cover of suitable size made of PVC, paint, varnish and a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Per Relay 20.00 | — | 1,045.76 | 20,915.2 |
| 58 | Fixing o f additional p l u g boards, 5 0 ways terminal b l o c k s a n d w i r i n g o f additional relays a s p e r t h e approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC s h a l l b e p r o v i d e d w h e r e v e r required. Alterations t o Re l a y particulars s h a l l be incorporated in the relay Index board.(Supply o f r e l a y s , p l u g b o a r d s , connectors and retaining clips and 50 way terminal boards is n o t covere d i n t h i s schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 2 5 m m thick for fixing resistors and condensers, soldering materials, bunching thread, w i r e wound resistance, condenser, wire supporting tray with cover o f suitable size made of PVC, paint, varnish and all other miscellaneousmaterials required for the work shall be supplied by the Contractor ] | Per Relay 58.00 | — | 726.5 | 42,137 |
| 59 | Carrying out alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 1 6 / 0 . 2 m m c o p p e r . T h e w o r k includes p a i n t i n g a l t e r a t i o n s a n d r e l e a s i n g the unwanted wires carefully without disturbing the existing wiring.[Wire P V C 16/0.2mm c o p p e r , soldering materials, bunching t h r e a d s , condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Per Relay 133.00 | — | 695.67 | 92,524.11 |
| 60 | Supply of Handheld True RMS Multi Meter, as per Technical specification | Numbers 9.00 | — | 23,192.34 | 2,08,731.06 |
| 61 | Supply of Handheld True RMS clamp Meter, as per Technical specification | Numbers 11.00 | — | 33,510.29 | 3,68,613.19 |
| 62 | Supply o f Double walled corrugated pipe - 103.5mm i n n e r d i a & 1 2 0 m m o u t e r dia conforming to specification No. IS 14930(Part 2 ) : 2001 with o n e coupler for every 6 m of pipe as per Technical specification | Metre 522.00 | — | 365.19 | 1,90,629.18 |
| 63 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre 340.00 | — | 1,119.16 | 3,80,514.4 |
| 64 | Supply o f HDP E Pipe 4 0 m m (outer dia)/33 mm (inner dia) with couplers | Metre 1000.00 | — | 60.93 | 60,930 |
| 65 | Supply of Track Feed Resistance | Numbers 5.00 | — | 287.77 | 1,438.85 |
| 66 | Supply of PBT terminals 25mm/ 60mm centre a n d P B T F u s e b l o c k s w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers 4850.00 | — | 61.44 | 2,97,984 |
| 67 | Supply of PBT terminals 25mm/ 60mm centre a n d P B T F u s e b l o c k s w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers 720.00 | — | 93.02 | 66,974.4 |
| 68 | Supply of PBT terminals 25mm/ 60mm centre a n d P B T F u s e b l o c k s w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers 290.00 | — | 103.84 | 30,113.6 |
| 69 | Supply of E-Type Locks | Numbers 5.00 | — | 1,234.88 | 6,174.4 |
| 70 | Supply of ND Fuse of various capacities (Per unit=Per fuse) | Per Unit 50.00 | — | 37.74 | 1,887 |
| 71 | E x c a v a t i o n o f p i t , e r e c t i o n o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm d i a a n d 300mm long a t t h e bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe f o r cable entry a n d o n e G I pipe 150mm long 32mm dia for drawl of jumper w i r e s f o r P o i n t machines e t c . , fi x i n g of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside a n d outside w ith o n e coa t of red-oxide and two coats of aluminium paints. | Numbers 4.00 | — | 5,029.69 | 20,118.76 |
| 72 | Installation of combined type point machine- I R S t y p e a n d c o n n e c t i n g a l l ground connections including wiring and termination i n p o i n t m a c h i n e a n d interconnections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision o f insulation to stretcher bars, t h r o w b a r l u g a n d "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration.(Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat w i r e P V C 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 3.00 | — | 16,383.88 | 49,151.64 |
| 73 | Excavation of pit,casting concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection of colour light signals up to 4 aspects.[Foundation bolts, cement, M sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 1.00 | — | 9,213.28 | 9,213.28 |
| 74 | "Excavation o f p i t a n d c a s t i n g concrete foundation as per Drg, No.SG/CN/02/10 using metallic templates, f o r erection of ground type colour light shunt signal. [Foundation bolts and nuts, cement, M sand, stone jelly of size 20/25mm a n d a l l other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers 2.00 | — | 4,645.17 | 9,290.34 |
| 75 | " E r e c t io n o f G r o u n d t y p e s h u n t signal complete including surface base, signal pole, L E D aspects/ l e n s e s , b u l b s w i t h holders (whichever i s applicable), fi x i n g o f lens guards, number p l a t e , termination o f tail cables, wiring o f signal unit w ith P V C wire 3/0.75mm copper, provision o f E W S locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint.(Supply of Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered in this schedule).[Wire PVC 3/0.75mm copper, lens guards, E W S locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials s h a l l be supplied by the Contractor]." | Numbers 2.00 | — | 3,170.44 | 6,340.88 |
| 76 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). b)Provision of track circuit in RE/Non RE area (other than point zone) | Numbers 2.00 | — | 7,145.44 | 14,290.88 |
| 77 | Alteration to existing DC Track Circuits to suit R E / N o n R E s t a n d a r d a s p e r approved signaling plan. This work includes provision o f d o u b l e bonding a n d parallel jumpers, provision o f b o n d w i r e c l i p s , wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lea d connections wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration to existing track circuits at feed end | Numbers 4.00 | — | 4,234.65 | 16,938.6 |
| 78 | Alteration to existing DC Track Circuits to suit R E / N o n R E s t a n d a r d a s p e r approved signaling plan. This work includes provision o f d o u b l e bonding a n d parallel jumpers, provision o f b o n d w i r e c l i p s , wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lea d connections wherever necessary using 2c x 2.5 sq.mm cable b)Alteration to existing track circuits at relay end | Numbers 3.00 | — | 3,850.31 | 11,550.93 |
| 79 | E x c a v a t i o n o f p i t , c a s t i n g concrete foundation a n d erection o f apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, ' E ' type locks, cement, M sand, stone jelly o f size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts a n d all other miscellaneous materials required for thework shall be supplied by the Contractor.] | Numbers 10.00 | — | 11,333.1 | 1,13,331 |
| 80 | Fixing of E-Type Lock | Numbers 5.00 | — | 308.03 | 1,540.15 |
| 81 | " E x c a v a t i o n o f pit, casting concrete foundation a n d erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing o n e ' E ' t y p e l o c k f o r t h e f r o n t d o o r and latching arrangement for the back door, and fixing o f o n e hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]""" | Numbers 7.00 | — | 8,787.04 | 61,509.28 |
| 82 | E x c a v a t i o n o f p i t , e r e c t i o n o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm d i a a n d 300mm long a t t h e bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for e a c h p i p e f o r c a b l e throughing, fi x i n g of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside a n d outside w ith o n e coa t of red-oxide and two coats of aluminium paints. (Supply o f C T boxes i s n o t covered i n this schedule. Rails o f different length shall be supplied by Railways. The contractor shall cut lengthy rails wherever required.)[Cement, M sand, s t o n e j e l l y o f size 20/25mm, paint, varnish, GI Pipes 32mm dia with clamp nuts - 12mm thick - 2 Nos. for eac h pipe, fixing b o l t s a n d n u t s with washers, E W S locks, paints and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers 5.00 | — | 4,999.16 | 24,995.8 |
| 83 | Excavation of pit in and around the existing l o c a t i o n b o x e s v e r y c a r e f u l l y without damaging t h e working cables a n d shifting and turning the location boxes to clear of the infringement a s instructed b y t h e Railway representative a t s i t e . T h e w o r k includes ensuring the safety of the signaling system, releasing t h e cable coils t o give access for s h i f t i n g / t u r n i n g t h e l o c a t i o n boxes. Necessary masonry work and earth work in a n d a r o u n d t h e l o c a t i o n b o x e s t o the required level shall be done as instructed by t h e Railway representative a t s i t e . I f the existing earth connections t o t h e location boxes are disturbed, the earth wires shall be properly re-connected. a) Shifting of apparatus case (full) | Numbers 5.00 | — | 5,348.81 | 26,744.05 |
| 84 | Excavation of pit in and around the existing l o c a t i o n b o x e s v e r y c a r e f u l l y without damaging t h e working cables a n d shifting and turning the location boxes to clear of the infringement a s instructed b y t h e Railway representative a t s i t e . T h e w o r k includes ensuring the safety of the signaling system, releasing t h e cable coils t o give access for s h i f t i n g / t u r n i n g t h e l o c a t i o n boxes. Necessary masonry work and earth work in a n d a r o u n d t h e l o c a t i o n b o x e s t o the required level shall be done as instructed by t h e Railway representative a t s i t e . I f the existing earth connections t o t h e location boxes are disturbed, the earth wires shall be properly re-connected. b) Shifting of apparatus case (half) | Numbers 7.00 | — | 3,545.06 | 24,815.42 |
| 85 | Termination o f n e w main/tail cables o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r approved circuit diagram. T h e terminal particulars a r e to be r e p a i n t e d / c o r r e c t e d o n t h e d o o r s of a p p a r a t u s c a s e s / b a t t e r y b o x e s / cable termination boxes and FTOT index board as instructed by Railway representative at site. T h i s w o r k i n c l u d e s c l o s i n g t h e opening create d f o r e n t r y o f n e w c a b l e s i n the apparatus cases w i t h masonry b r i c k work a n d sealing t h e bottom o f t h e apparatus cases/ cable termination r a c k s w i t h cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials shall be supplied by the contractor].(Per Unit = Per Terminal block) | Per Unit 545.00 | — | 73.59 | 40,106.55 |
| 86 | Termination o f m a i n , t a i l , Signaling and power cables and internal wiring on terminal/ fuse blocks i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding c a b l e termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood b a s e p l a n k , fi x i n g o f P h y n o l i c synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit e a c h a p p a r a t u s c a s e , v a r n i s h i n g all teakwood items, fi x i n g o f terminals/ fuse b l o c k s o n t h e terminal b o a r d , drilling of n e c e s s a r y h o l e s , termination o f cables, w i r i n g , identifica tio n o f c a b l e s using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable p l a n , painting o f particulars o n sleeves andalso o n t h e inner s i d e o f t h e doors of apparatus cases. After terminations are "over, t h e side openings o f apparatus case foundation shall b e closed w ith brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e level a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n t h i s schedule)." a)Termination o n 25/60mm P B T terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit 1500.00 | — | 172.14 | 2,58,210 |
| 87 | Termination o f m a i n , t a i l , Signaling and power cables and internal wiring on terminal/ fuse blocks i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding c a b l e termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood b a s e p l a n k , fi x i n g o f P h y n o l i c synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit e a c h a p p a r a t u s c a s e , v a r n i s h i n g all teakwood items, fi x i n g o f terminals/ fuse b l o c k s o n t h e terminal b o a r d , drilling of n e c e s s a r y h o l e s , termination o f cables, w i r i n g , identifica tio n o f c a b l e s using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable p l a n , painting o f particulars o n sleeves andalso o n t h e inner s i d e o f t h e doors of apparatus cases. After terminations are "over, t h e side openings o f apparatus case foundation shall b e closed w ith brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e level a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n t h i s schedule)." b)Termination o n P B T f u s e b l o c k (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit 90.00 | — | 209.93 | 18,893.7 |
| 88 | Termination o f m a i n , t a i l , Signaling and power cables a n d internal wiring b y fixing additional terminals/ f u s e b l o c k s o n the existing terminal boards of apparatus cases, c a b l e termination b o x e s e t c . T h e work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse block s, o n t h e existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and a l s o o n t h e i n n e r s i d e o f t h e d o o r s of apparatus cases. After terminations are over, t h e s i d e o p e n i n g s o f a p p a r a t u s case foundation shall b e closed w ith brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e level a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound. a)Termination o f c a b l e s on 25/60mm PBT terminals (existing location) (Per Unit = Per Terminal block) | Per Unit 580.00 | — | 151.09 | 87,632.2 |
| 89 | Termination o f m a i n , t a i l , Signaling and power cables a n d internal wiring b y fixing additional terminals/ f u s e b l o c k s o n the existing terminal boards of apparatus cases, c a b l e termination b o x e s e t c . T h e work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse block s, o n t h e existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and a l s o o n t h e i n n e r s i d e o f t h e d o o r s of apparatus cases. After terminations are over, t h e s i d e o p e n i n g s o f a p p a r a t u s case foundation shall b e closed w ith brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e level a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound. b)Termination o f cables o n PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit 75.00 | — | 188.86 | 14,164.5 |
| 90 | Carrying out alterations to the existing SM's control panel. T h e w ork includes drilling of holes o n t h e To p plate wherever required, fixing and wiring of knobs, buttons, counters, LEDs with holder, closing of unwanted holes, carrying o u t painting alterations o n the panel, termination of additional cables and carrying out alteration to the existing wiring as per approved circuit diagram, releasing of unused wires, and painting of particulars as per the instructions of Railway representative at site.(Supply o f knobs, buttons and counters is not included in the scope of this schedule). [LED l a m p s with holder, p a i n t , soldering materials a n d all other miscellaneous materials required for t h e w o r k s h a l l be supplied by the Contractor]. | Lumpsum 2.00 | — | 15,967.35 | 31,934.7 |
| 91 | Excavation of pit, concreting 'A' type foundation and fixing ground lever frames single/double as per Drg.No.SG/CN/02/11 complete with ground connection. The work includes concreting of 'A' type foundations and fixing of HP lock and connecting the ground lever frame with the HP lock using MS rod as instructed by Railway representative at site. (Refer Chapter-20, 17.1)(Supply of ground lever frames, hand plunger locks and 'A' type foundations is not covered in this schedule).[Cement, M sand, stone jelly of size 20/25mm, fixing bolts and nuts with washers and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers 1.00 | — | 8,351.55 | 8,351.55 |
| 92 | Interlocking of level crossing gate with Lifting Barrier: This work consists cutting of notches on the drum of the winch, , fixing and leveling of trestles, rod roller assembly, leveling and concreting of 'A' type foundations, fixing of rod diversion cranks, vertical cranks, running of rods (app. 30mtrs.) and connecting them to lever tail at one end and boom locking arrangement at the other end, and painting as per standard practice. The work also includes fixing of wiring of one limit switch for each boom as per the instructions of Railway representative at site. (Supply of HP locks,rods, 'A' type foundations, trestles, segments, rod roller assembly complete and cranks is not covered in this schedule). [Cement, M sand, stone jelly of size 20/25mm dia, coal bengal, paints, all types of bolts & nuts and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers 1.00 | — | 22,772.95 | 22,772.95 |
| 93 | Provision of HDPE Pipe of dia 40/33 mm | Metre 1000.00 | — | 26.11 | 26,110 |
| 94 | "Breaking of concrete and releasing of STOP board/Warning board/ LEGEND boards along w i t h r a i l s , accounting a n d stacking them neatly a t a place a s instructed b y Railway representative at site. Also the resultant pits s h a l l b e re-surfaced a n d consolidating by ramming and levelling" | Numbers 1.00 | — | 1,580.36 | 1,580.36 |
| 95 | Releasing o f existing apparatus cases (Full/ H a l f / Quarter s i z e ) without d a m a g e after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f all t y p e s E K T s , S e c o n d a r y Cells, power equipments, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall b e accounted and stacked a t a place a s instructed by Railway representative at site. | Numbers 17.00 | — | 3,006.71 | 51,114.07 |
| 96 | Breaking o f concrete a n d releasing the e x i s t i n g c a b l e termination b o x e s , after releasing t h e b a s e plank, Terminal blocks, F u s e B l o c k s , Terminal B o a r d s , c u t rails, pipes, e t c . , closing t h e resultant p i t s and consolidating i t b y ramming a n d levelling. T h e released materials shall b e accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers 3.00 | — | 2,004.94 | 6,014.82 |
| 97 | Dismantling and releasing of ground lever frame along with all connected gadgets like lever locks, 'E' type locks, HP locks, etc., accounting and stacking them neatly at a place as instructed by Railway representative at site. The work also involves breaking and removal of concrete foundation and the resultant pit shall be filled and consolidated by ramming and levelling. | Set 1.00 | — | 5,550 | 5,550 |
| 98 | Releasing o f p o i n t r o d s w i t h r o d roller trestles, complete assembly. T h i s includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits a r e t o be covered with earth and consolidated b y ramming and levelling. c)Releasing of point roddings | Metre 12.00 | — | 14.71 | 176.52 |
| 99 | Releasing of existing TLD boxes with stumps a n d terminals after releasing a l l t h e bond w i r e s . T h e r e l e a s e d m a t e r ia ls s h a l l be accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers 20.00 | — | 159.29 | 3,185.8 |
| 100 | Transportation of Signalling materials by road a s p e r t h e i n s t r u c t i o n s o f Railway representative at site. The work also includes l o a d i n g a n d unloading o f the materials a)Transportation of Signalling materials upto 100kms | MT-Km 800.00 | — | 22.75 | 18,200 |
| Schedule total | ₹2,31,72,544.52 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC2022.pdf
ATTACHMENT
GCCcorrectionslipsupload.pdf
ATTACHMENT
SOR2022BOOKLET.pdf
ATTACHMENT
PV1.pdf
ATTACHMENT
CableCutpenaltyLetter.pdf
ATTACHMENT
ModelformofBankGuarantee.pdf Model form of Bank Guarantee
ATTACHMENT
ATCandscopeofwork.pdf
ATTACHMENT
ModelformofBankGuarantee.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .