Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
₹1.2 L
EMD Value
₹3,092
Closing Date
7 Jan 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer
O/O AEE Edappilly Block Panchayath
Electrification
2025_LSGD_815853_2
1(14)/ AE/EBP/2025-26
Open Tender
Electrical Works
Percentage
180 days
Kakkanad
Please refer Tender documents.
3 documents required · 3 mandatory
₹555
Yes
₹3,092
Yes
4 Mar 2026
30 Dec 2025
12 Jan 2026
30 Dec 2025
7 Jan 2026
30 Dec 2025
ESTIMATE
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
OD328169/2025-2026:Shifting, wiring, installation and commissioning of existing single control light point with out ceiling rose to an approx. distance to 2 meters from the existing postion for shifting recessed type ceiling lights fitted on existing ceiling.
OD316870/2025-2026:Supply, installation, making connections and commissioning of following size recessed LED panel light (Back lit Down light) fitting at ceiling surface, with physical dimension approx. 595mm x 595mm or 595mm dia, in the existing down light mounting frame work at hole cutout on the ceiling material. Back lit Down light, Make/Model: Philips-Full Flow G6/Osram/Wipro/Crompton or equivalent reputed make and model. Recessed LED panel Backlit down light 35-40W, Lumens /Watt - 120-100, 230V single Phase AC Supply.
OD328290/2025-2026:Supply, Installation and commissioning of fitting bracket for recessed led light at existing ceaing cutout with approx. dia 600mmx600m
OD328294/2025-2026:Supply, Installation and commissioning of fitting bracket for recessed led light at existing ceaing cutout with approx. dia 300mmx300m
OD316957/2025-2026:Making/cutting suitable sixe hole cutout in square/round shape for following size recessed LED panel light (Back lit Down light) fitting at ceiling surface, with physical dimension approx. 300mm x 300mm x 35m or 300mm dia, on the ceiling material, with aesthetic look and manner.
OD318113/2025-2026:Making/cutting suitable sixe hole cutout in square/round shape for following size recessed LED panel light (Back lit Down light) fitting at ceiling surface, with physical dimension approx. 600mm x 600mm x 35m or 600mm dia, on the ceiling material, with aesthetic look and manner.
OD316958/2025-2026:Dismantling from the existing location, transportation & handling, refitting the same at new location, making connections and commissioning at the best, of following size recessed LED panel light (Back lit Down light) fitting at ceiling surface, with physical dimension approx. 300mm x 300mm x 35m or 300mm dia, in the existing down light mounting frame work at hole cutout on the ceiling material. Refitment of Recessed LED panel Backlit down light 18W, Lumens /Watt - 120-100, 230V single Phase AC Supply.
OD316975/2025-2026:Supply, installation and commossioning of LED Strip Lights at existing provisions/slots/cealing surface with suitable fixing accessories, Equivalent to Luker make LSI 2835 or any other reputed equivalent make - 12V
OD316976/2025-2026:LED Strip Driver Unit- 12V 5W, Equivalent to Luker make model LSD03 or equivalent reputed make., suitaable to drive 12V LED strip.
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
OD328302/2025-2026:Supply, conveyance, installation, testing and commissioning of the following type high wall mounted Split type Air conditioner unit, super quiet and capable to operate on continuous mode to make proper air flow, cooling and de-humidification of the area, Refrigerant type used R-22/R-32/R-410, non CFC refrigerant, with copper condensing and evaporating unit capable for cooling, provided with cordless remote control, 22 SWG soft drawn copper refrigerant pipe with rubber seal and foam sleeve, 25mm PVC drain pipe etc. up to 3 meter, including warrantee service up to 3 year, Make - Daikin / Carrier / Mitsubishi or equivalent reputed make. High wall split type Air conditioner Unit – Inverter type –1TR, 3 Star rating.
OD328303/2025-2026:Supply, conveyance, installation, testing and commissioning of the following high wall mounted Voltage Stabiliser for Air conditioner operation, with input voltage range 170V-270V and output voltage range 210V-230V, with overload protection cut off, time delay, indicator and chord wire etc. as required. Wall mounted Voltage Stabiliser for 1.0 / 1.5/2.0Ton AC unit, 3.0kVA, 230VAC
OD328304/2025-2026:Supply and installation of wall bracket / frame for outdoor unit of High wall split type air conditioner units for 1/1.5/2 TR units.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1382530.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
viewnit.pdf
Tender Documents • 0.03 MB
viewsbd.pdf
Tender Documents • 2.96 MB
BOQ_1382530.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .