EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Renovation /Repair of Town Hall at MC Kunzer B.W.O Electric work
2025_PWDJK_292982_1
NIT No.158/2025-26 Dt/23/10/2025
Open Tender
Electrical Works
Percentage
KUNZAR
Please refer Tender documents.
4 documents required · 4 mandatory
₹600
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹16,687
23 Oct 2025
23 Oct 2025
4 Nov 2025
23 Oct 2025
3 Nov 2025
23 Oct 2025
Part-A (Internal Electrification)
Wiring for Light point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells/Polycab/RR-Kabel/Anchor Make) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 25mm) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells/ Legrand/Panasonic/Anchor/Schneider/ eq. Make & shall be approved by EIC before execution of work.
Wiring for Ceiling fan point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable in surface/recessed Conduits (Including Cost of Conduit 25mm) (Havells/Polycab/RR-Kabel/Anchor Make)with 01 No. of 6 Amp Modular Switch,, Modular Plate,Cover in front and suitable GI box etc ISO/IEC Certified Havells/ Legrand/ Panasonic/ Anchor/ Schneider/ eq. Make & shall be approved by EIC before execution of work.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Havells/ Legrand/Panasonic/Anchor/Schneider / eq. Make & shall be approved by EIC before execution of work.
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/RR-Kabel/Anchor / eq. Make & shall be approved by EIC before execution of work.)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor/Schneider/ eq. Make & shall be approved by EIC before execution of work.(Loop for 2 Points)
Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/RR-Kabel/Anchor / eq. Make & shall be approved by EIC before execution of work.) Loop for 2 points
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor/Schneider/ eq. Make & shall be approved by EIC before execution of work.
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/RR-Kabel/Anchor/ eq. Make & shall be approved by EIC before execution of work.
2x10 sq.mm+ 1x10 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards.
2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/AC Sub main in One run from Main Panel to Distribution Boards.
2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Inverter Circuit in One run from switch boards to Distribution Boards.
Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schinder / eq. Make & shall be approved by EIC before execution of work.)
Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/ABB /Schinder / eq. Make & shall be approved by EIC before execution of work.)
Supplying and Fixing of MCB 8-Way (4+24) horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider / eq. Make & shall be approved by EIC before execution of work.)
Supplying and Fixing of MCB 8-Way horizontal typed , sheet steel, Double Door Distribution Board, SPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider / eq. Make & shall be approved by EIC before execution of work.)
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.
Supply/Installation/Testing and Commissioning of 18W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of HG/Wipro/Baja/Jaquar / eq. Make & shall be approved by EIC before execution of work..
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote with cells or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection,Ceiling Rose,Silken wire also with round plates Etc complete. etc USHA/Polycab/LUKER USA/Anchor / eq. Make & shall be approved by EIC before execution of work.
Supply/Installation/Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified.
Supply/Installation/Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G,acetylene and electrical fires.
Supply/Fixing/Testing and Commissioning of 400 mm 3 Blades Wall Fan with Remote Control.) Havells/Orient USHA / eq. Make & shall be approved by EIC before execution of work.
Supply/Laying of 25/32/38mm Dia PVC Conduit of Anchor/Ravinder/Polypack/Finolex Make with other accessories like bends,etc complete to be laid in wall for downs and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Tile/Wooden Penelling with same Colour/Paint etc.
Providing and fixing of bakelite hylam sheets of required size including cutting, filing with S/F screws etc.
Supply/Installation/Testing and Commissioning of 3-Phase, Four Pole 100 Amp,415V Ac,50Hz Bypass Switch with ROH in enclosure Havells/L &T/ABB Make including S/F/Crimping of Suitable Size of thimbles for connections as per site requirement for bypassing Existing AVR. as approved.
Supply/Laying/Connecting and Commissioning of 70 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/KEI/RR-Kabel Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench.
Supply/Installation/Testing/Commissioning of SOLARVERTER PCU 03.5-4.5 KVA/48 V Pure Sinewave Solar Inverter With ISOT Technology, Intelligent Load Sharing & BIS Certified (with 2-Year Warranty), 04 No. of 200Ah,12V Tubular battery (with 60 Months Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc Havells/Luminious/EXIDE /AMRON / eq. Make & shall be approved by EIC before execution of work.. for Hall
Dismentling of existing wires in scraps ,switches ,sockets ,fixtures etc and handing over the same to conerned authorities.
Part-B (Air Conditioner)
Supply and Fixing of Modular 32Amp industrial Socket outlet having fitted with 32 Amps DP MCB and Top with Modular Plate,Cover in front & suitable GI box etc for AC Points Havells/Legrand/Schinder / eq. Make & shall be approved by EIC before execution of work.
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/RR-Kabel/Anchor / eq. Make & shall be approved by EIC before execution of work..2x6 sq.mm+ 1x6 sq.mm (P+N+E) for LAC Sub main in One run from Main Panel
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.07 MB
BOQ_946014.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .