Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | LI₹9.8 LAccepted-AOC | LI | Accepted-AOC L1 | |
| 2 | L2₹10.0 LRejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹12 L
EMD Value
₹30,000
Closing Date
21 Nov 2019, 5:00 pmClosed
AE,LSGD SECTION,VENGOLA
ASSISTANT ENGINEER ,LSGD SECTION VENGOLA
CULVERT CONSTUCTION
2019_LSGD_317254_1
10/ET1/AE/VGLA/19-20
Open Tender
Civil Works - Roads
Item Wise
150 days
WARD-21
PLEASE REFFER TENDER DOCUMENTS
5 documents required · 5 mandatory
₹2,500
EXCUTIVE ENGINEER LSGD SECTION ERNAKULAM
₹30,000
3 Jan 2020
4 Nov 2019
25 Nov 2019
4 Nov 2019
21 Nov 2019
4 Nov 2019
4 Nov 2019 - 21 Nov 2019
Amount
culvert
2.5.2.B : Dismantling of Structures<br> Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.<br> (II) By Mechanical Means <br>(B) Reinforced Cement Concrete
2.7.B : Dismantling Stone Masonry as per Technical Specification Clause 202.Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.(B)Rubble Stone Masonry in Cement Mortar
11.1.1.1 : Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I.Ordinary soil(i)Upto 3 m depth
11.1.1.2 : Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I. Ordinary soil (ii)3 m to 6 m depth
11.4.1.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203I.P.C.C grade M 10(i)Nominal mix 1:3:6
12.5.1.1 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 mI.P.C.C grade M 15(i)Nominal mix (1:2.5:5)
12.7 : Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
12.5.3 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 m III.R.C.C grade M 20
13.3 : Supplying, fitting and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002,1010 and 1202
13.1.2 : Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5R.C.C M 25
3.4 : Construction of Embankment with Material Obtained from Borrow Pits <br> Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
od208664/2019_2020 : Granular sub base using Gravel mixture/Quarry waste
od208657/2019_2020 : Providing concrete for plain/ reinforced concrete,using 40 mm graded brocken stone (Form work excluded, cement content changed to 170 kg/m3)1.P.C.C grade M10(i) Nominal mix 1:3:6
od159430/2019_2020 : DRY RUBBLE MASONRY with departmental stone_ Dry rubble without concrete levelling course using departmental rubble including packing to compactness to lines and levels, labour charges etc.
3.2 : Preparation of Foundation for EmbankmentScarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical MeansScarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
od159444/2019_2020 : Providing and laying 80mm thick factory made cement concrete interlocking paver block of M30 grade made by block making machine with strong vibratory compaction, of approved size design & shape, laid in required color and pattern over and including 50 mm thick compacted bed of 6 mm metal all complete as per the direction of Engineer - in- charge
od209985/2019_2020 : Providing Concrete for plain/ reinforced concrete using 20 mm graded brocken stones (Form work excluded' cement content changed to 320 kg /m3, 40 mm aggregate excluded,20 mm-.54 m3 and 10 mm .36m3) P:C:C grade M20 (i) nominal mix (1:2:4)
SUNIL.K.M.
Bidder Name
SUNIL.K.M.
Abeesh Mon P.A
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_437432.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .