| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹44.0 L+₹4.2 L (10.5%)Rejected-AOC 36A 60 CIVIL LINE TELIYAR GANJ ALLAHABAD UTTAR PRADESH 211004 | PRAYAGRAJ | UTTAR PRADESH | 211004 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹44.9 L+₹5.1 L (12.7%)Rejected-AOC H NO 3927 SHAH COLONY SECTOR 8 NEAR NHPC COLONY SAILI ROAD TEHSIL DISTT PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹45.1 L+₹5.3 L (13.2%)Rejected-AOC 0 0 NAGLA MALOO MOHAMMDABAD FARRUKHABAD FARRUKHABAD FARRUKHABAD UTTAR PRADESH 209625 | FARRUKHABAD | UTTAR PRADESH | 209625 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹46.4 L+₹6.5 L (16.4%)Rejected-AOC 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | Ansh Enterprises L1 | V r traders L5 | M/s Pradeep Kumar L3 | Mahamaya Engineers Services L6 | V S ENTERPRISES L4 | Pragati Enterprises L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for broken stone or boulders hardcore of gauge nexc. 63 mm, deposited, spread and levelled in layers nexc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. | 20 | Cubic metre | 1,780 ₹35,600 | 1,899 ₹37,980 | 1,100 ₹22,000 Lowest | 1,600 ₹32,000 | 1,200 ₹24,000 | 1,600 ₹32,000 |
| 2.00 | Material and labour for hardcore of gauge exc 63 mm but n.exc 100 mm deposited, spread and leveled in layers n.exc 15 cm thick, watered and rolled/rammed to a true surfaces in broken stone or boulder complete all as specified and as directed. | 1.8 | Cubic metre | 2,125 ₹3,825 | 1,899 ₹3,418.2 | 2,100 ₹3,780 | 2,200 ₹3,960 | 1,200 ₹2,160 Lowest | 1,600 ₹2,880 |
| 3.00 | Material and labour for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone agg as in sub base complete all as specified and directed. | 212 | Square metre | 412 ₹87,344 | 299 ₹63,388 | 240 ₹50,880 Lowest | 280 ₹59,360 | 300 ₹63,600 | 300 ₹63,600 |
| 4.00 | Material and labour for 25 mm thick PCC (1:2:4) type B-1 using 20 mm graded stone agg as in base or floors complete all as specified and directed. | 212 | Square metre | 190 ₹40,280 | 169 ₹35,828 | 120 ₹25,440 | 100 ₹21,200 Lowest | 150 ₹31,800 | 220 ₹46,640 |
| 5.00 | Material and labour for 20 to 25 mm thick Machine cut kota stone slab flooring over 15 mm thick screed base laid in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed. | 150 | Square metre | 980 ₹1,47,000 | 1,299 ₹1,94,850 | 960 ₹1,44,000 | 900 ₹1,35,000 Lowest | 1,000 ₹1,50,000 | 1,100 ₹1,65,000 |
| 6.00 | Material and labour for excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removing surplus soil to a distance n exc 50m and making good surface in any type of soil complete all as specified and directed. | 6 | Each | 165 ₹990 | 149 ₹894 Lowest | 250 ₹1,500 | 400 ₹2,400 | 300 ₹1,800 | 250 ₹1,500 |
| 7.00 | Material and labour for cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed. | 0.75 | Cubic metre | 5,250 ₹3,937.5 | 3,999 ₹2,999.25 | 4,800 ₹3,600 | 4,000 ₹3,000 | 3,500 ₹2,625 Lowest | 4,800 ₹3,600 |
| 8.00 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and as directed. | 20 | Square metre | 58 ₹1,160 | 39 ₹780 | 60 ₹1,200 | 30 ₹600 Lowest | 30 ₹600 Lowest | 50 ₹1,000 |
| 9.00 | Material and labour PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) for foundation/ mass concrete complete all as specified and as directed. | 8.07 | Cubic metre | 5,250 ₹42,367.5 | 3,999 ₹32,271.93 | 4,000 ₹32,280 | 4,500 ₹36,315 | 3,200 ₹25,824 Lowest | 4,000 ₹32,280 |
| 10.00 | Material and labour cement concrete 1:2:4 type B0 40mm thick in Damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed. | 12 | Square metre | 180 ₹2,160 Lowest | 259 ₹3,108 | 300 ₹3,600 | 300 ₹3,600 | 200 ₹2,400 | 300 ₹3,600 |
Tender Value
₹49.6 L
EMD Value
₹99,200
Closing Date
31 May 2025, 6:00 pmClosed
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Spl repair of external electrification including LT panels, LT cables street light at 501 FSEG, at 109 Rajpur Road, certain minor works and revenue works under GE Dehradun.
2025_MES_706650_1
8937/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE Dehradun
Class D cat a (i) and b (i)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹99,200
Yes
1 Sept 2025
3 May 2025
2 Jun 2025
3 May 2025
31 May 2025
17 May 2025
Amount
Material and labour for broken stone or boulders hardcore of gauge nexc. 63 mm, deposited, spread and levelled in layers nexc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Material and labour for hardcore of gauge exc 63 mm but n.exc 100 mm deposited, spread and leveled in layers n.exc 15 cm thick, watered and rolled/rammed to a true surfaces in broken stone or boulder complete all as specified and as directed.
Material and labour for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone agg as in sub base complete all as specified and directed.
Material and labour for 25 mm thick PCC (1:2:4) type B-1 using 20 mm graded stone agg as in base or floors complete all as specified and directed.
Material and labour for 20 to 25 mm thick Machine cut kota stone slab flooring over 15 mm thick screed base laid in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
Material and labour for excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removing surplus soil to a distance n exc 50m and making good surface in any type of soil complete all as specified and directed.
Material and labour for cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and as directed.
Material and labour PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) for foundation/ mass concrete complete all as specified and as directed.
Material and labour cement concrete 1:2:4 type B0 40mm thick in Damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.
Material and labour RCC 1:2:4 nominal mix type B1 using 20 mm graded stone aggregate as in column footing including raft footings, foundation, plinth beam, bases of columns etc. complete all as specified and as directed.
Material and labour for Providing precast cement concrete 1:2:4 nominal mix type B1 (using 20 mm graded aggregate) set in cement mortar 1:4 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed.
Material and labour TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Description all as ser no 13 above but 8mm dia as in stirrups, spacers and binders complete all as specified and as directed.
Material and labour TMT bars 06 to 08 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Material and labour for formwork to sides of concrete foundation, footing, bases of columns, plinth beam, side and soffits of plinth beam and similar works in vertical or to batter of fair finished surfaces complete all as specified and as directed.
Material and labour Formwork flat rough finished to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening complete all as specified and directed.
Material and labour for preparing new plastered surfaces and applying 3 coats of white wash on walls complete all as specified and as directed.
Material and labour for moorum / red bajari filling in floors or pavings, laid in layers n exc 15 cm thick, spread, levelled and rammed including watering and duly consolidating complete all as specified and directed.
Material and labour for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement complete all as specified and directed. Note:- The plinth protection shall be laid in panels and lenth of each panel shall not be more than 3.00 m and at every turning and 10mm joints filled with 85/25 grade bituman and sand mixture in the ratio (1:3) shall be provided
Supply and fix factory made steel window with side hung shutters including projecting/box/pin type hinges with steel handle, steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
Supply and fix factory made steel window with side hung shutters including projecting/box/pin type hinges with steel handle, steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
Supply and fix PVC solid factory made door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
Supply and fix Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
Material and labour for 150 mm Salt-glazed stoneware drain pipes laid in trenches and jointed complete all as specified and directed.
Material and labour for concrete bed in 1:3:6 type C2 to 150 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Supply and fix for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed.
Supply and fix for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410-W(Gde E-250) quality-A complete all as specified and directed.
Supply and fix for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Material and labour for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description over 10 cm width or girth & complete all as specified and directed.
Material and labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortor 1:6 complete all as specified and as directed.
Material and labour Brickwork with subclass ‘B’ bricks in cement mortar 1:4, straight or curved on plan to any radius in half brick thick walls built in cement mortar complete all as specified and directed.
Material and labour for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:6, surface finished even and smooth (without using extra cement) complete all as specified and directed.
Material and labour for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4, surface finished even and fair complete all as specified and directed.
Material and labour for preparation of newly plastered surface of walls including corners and applying two coats of distemper oil emulsion over applying of 1-2 mm thick wall care putty finish wall surface even & smooth complete all as specified and directed.
Material and labour for preparation of newly plastered surface of walls including corners and applying two coats of cement based paint over a coat of cement primer complete all as specified and directed.
Supply and fix of hollow profile PVC Wall Lining consisting of 5mm thick of wood grains PVC sheet inclusive of solvent cement and fixing to walls on PVC frame as per specifications and drawing incl cover & support fillets complete all as specified and directed.
Material and labour for coloured joint free non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors, skirting etc. set and jointed in neat cement slurry @ 3.00 Kg/Sqm and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 etc complete all as specified and directed.
Material and labour for coloured Glazed ceramic tiles in vertical surfaces of size 350mm x 250mm x 7mm/ 450x 350 x 7mm thick over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry @ 3.00 Kg/Sqm and pointed in white or coloured cement to match complete all as specified and directed.
Supply and fix 150 mm long aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and directed.
Supply and fix 150 mm long Aluminium anodised handles of fabricated type complete all as specified and directed.
Supply and fix 4 mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sq. m in each pane complete all as specified and directed.
Supply and fix for mild steel framed work such as door frames, grills, gratings, etc, with ends of bars shouldered and / or riveted or forged into spikes; framed guard bars; frame work of water tanks and similar work confirming to Fe-290 Gde-E-165 including necessary welding, drilling hole complete all as specified and directed.
Supplying, fixing, jointing and testing galvanised steel water tubing 15 mm dia bore medium grade with all fittings such as bends, tees, nipples, elbows, socket reducers, etc, fixed to walls and ceilings or laid in floors complete all as specified and directed.
Supplying, fixing, jointing and testing galvanised steel water tubing 20 mm dia bore medium grade with all fittings such as bends, tees, nipples, elbows, socket reducers, etc, fixed to walls and ceilings or laid in floors complete all as specified and directed.
Material and labour cutting chases for concealed water tubing or concealed conduit wiring, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges, etc., cutting not exc 10 cm width or girth complete all as specified & directed.
Supply and fix Vitreous China Urinals, half stall type white (back or corner wall type), complete including providing and fixing plugs, bedding urinals against wall in CM 1:2, securing urinals to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, CP waste coupling, waste pipe, automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed.
Supply and fix vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) water closet, including connection to trap and to flushing pipe, anti syphonage pipe etc, and making good to floor complete all as specified and directed.
Supply and fix 10 litres capacity PVC low level valve less symphonic action type flushing cistern white with inlet, float valve, float and handle including brackets with 32 mm dia PVC pipe 600 mm long complete all as specified and directed.
Supply only PVC connection 15 mm dia 450 to 600 mm long with brass fly nut at both ends complete all as specified and directed.
Supply and fix 1000 ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, including supply & fix 20 mm dia GI light grade wash out pipe 450 mm long with plug and 20 mm dia GI light grade over flow pipe 600 mm long with fitting complete all as specified and directed.
Supply & fixing ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 25 mm bore size complete all as specified and directed.
Supply and fix 20 mm bore Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix Vitreous China wash hand basin, white, flat back type of size 550mm x 400 mm fixed on and including cast iron cantilever bracket, 32 mm dia brass waste coupling and 32 mm dia PVC waste pipe, grating dome, etc including fixing of tap, waste fitting etc complete all as specified and directed.Note: Pillar tap shall be measured as supply only under respective item.
Supply and fix 15mm dia swan neck pillar tap (for oval type WHB) brass chromium plated with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, and fixed complete all as specified and directed.
Supply and fix brass chromium plated angle cock 15 mm dia screwed for iron pipe or brass ferrule complete all as specified and directed.
Supply and fix 15 mm bore bib taps, chromium plated cast copper alloy long body, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
Supply and fix Chromium Plated brass soap dish fixed to wall with chromium plated brass screwed and cup washer complete all as specified and directed.
Supply and fix brass chromium plated towel rail, 20 mm dia 'D' type 60 cm long between flanges complete all as specified and directed.
Material and labour PVC (SWR) floor trap plain with grating including jointing with solvent cement 75 mm bore outlet complete all as specified and directed.
Supply and fix PVC (SWR) soil waste & vent pipe in any length without ears laid in floors, trenches or fixed to wall complete for 75 mm dia bore of pipe complete all as specified and directed.
Supply and fix PVC (SWR) soil waste & vent pipe in any length without ears laid in floors, trenches or fixed to wall complete for 110 mm dia bore of pipe complete all as specified and directed.
Supply and fix PVC (SWR) bends, T, reducer any radius with rubber ring joints, fixed to wall / floor / in trenches for 75 mm dia pipe complete all as specified and directed.
Supply and fix PVC (SWR) bends, T, reducer any radius with rubber ring joints, fixed to wall / floor / in trenches for 110 mm dia pipe complete all as specified and directed.
Supply and fix 110 mm dia PVC (SWR) vent cowl complete all as specified and directed.
Material and labour for pre-polished pavement coloured chequred tiles glossy finish of size not less than 300 x 300 x 20-22mm thick with anti skid properties laid over 20 mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed.
Material and labour for 65 mm thick reinforced precast cement concrete 1:1:2 type B-1 (using 20mm graded stone aggregate) as in man cover bromatic slabs finish fair even and smooth without using extra cement ( Top surface will be chequred finish) including necessary form work including 2mm thick CR sheet with 2 coastly of bitumen paint and two nos PVC counter sunk handle 12mm dia to surface, complete all as specified and directed.
Material and labour Septic tank,exc, in ordinary soil, foundation in PCC 1:2:4 , brick work in CM 1:4 , RCC Slab covers including RCC precast manhole cover having 6 mm plate embedded all around/fibre reinforced cover with angle iron frame Vent and sludge chambers etc., complete for 25 users complete all as specified and directed.
Material and labour soakage wells exc, in ordinary soil, foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 concrete, including intercepting chamber, screen chamber brick work in CM, RCC cover slab in M-25/RR masonry/Filling with brick bats, complete of size 1.2 M dia X 3.0 M deep complete all as specified and directed.
Supply and fix powder coated aluminium ventilator fixed type half glazed and half gauged with and including hardware fittings, glazing, wire gauge, rubber packing, aluminium beading etc. as specified below including taking down old window/ventilator and making good of wall surface to match with existing surface complete all as specified and directed : - Frame : 44.5 x 44.5 mm x 1.80 mm thick Middle rail : 44.5 x 44.5 mm x 1.80 mm thick Glazing: 5 mm thick frosted glass fixed with rubber gasket and aluminium beading. Wire gauge: stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm fixed with aluminium beading.
Material and labour for providing & fixing false ceiling of Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grams, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and cross 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable wire of 4mm dia with galvanised butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width complete all as specified and directed.
Supply and fix for hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete/brickwork and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Supply and fix for Expanded metal weight nexc 4 kg/Sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and directed.
Material and labour for glazed ceramic colour tiles size 300 mm x 450 mm/ 300 mm x 600mm x 6-7 mm thick on vertical surfaces such as dado, skirting etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 complete all as directed and specified.
Supply and Laying XLPE insulated galvanised steel strip or wire armoured elctric power cable with stranded aluminium conductor 1100 V grade of size 120 sqmm 3.5 core after cutting to required length with necessary glands, nuts, bolts, and lugs including taking out existing unserviceable cable etc complete all as specified and directed
Description all as per item No 77 above but XLPE cable of size 10 Sqmm 4 Core complete all as specified and directed.
Supply and Laying XLPE insulated galvanised steel strip or wire armoured elctric power cable with stranded aluminium conductor 1100 V grade of size 95 sqmm 3.5 core after cutting to required length with necessary glands, nuts, bolts, and lugs including taking out existing unserviceable cable etc complete all as specified and directed
Supply and Laying XLPE insulated galvanised steel strip or wire armoured elctric power cable with stranded aluminium conductor 1100 V grade of size 50 sqmm 3.5 core after cutting to required length with necessary glands, nuts, bolts, and lugs including taking out existing unserviceable cable etc complete all as specified and directed
Supply, laying, jointing and testing of underground XLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 2 Core laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs of cable size complete all as specified and directed.
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unseviceable LT Cable for laying of cable and getting out complete all as specified and directed.
Material and labour for Sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for brick well burnt Class ‘B’ as cover to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches complete all as specified and directed.
Material and labour for GI tubing medium grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed of size 40mm dia complete all as specified and directed.
Material and labour for GI tubing medium grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed of size 60mm dia complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-1 (using 20 mm crushed stone aggregate) as in coping of poles etc including form work complete all as specified and directed.
Material and labour for cutting existing road/hardstand of any type by using crow bar chisel uprto a depthof 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Supplying, transporting, erecting and fixing steel tubular swaged poles type 410 SP-31, 9.00 meter long, complete with cast iron base plate, heat resistance finial taper plug, bolts, nuts and screws as specified including painting with two coats of epoxy aluminum paint over one coat of red oxide primer and 06 Nos bands/straps with white and black colour (30 cm wide each) epoxy heat resistant paint at a distance 30 cm from plinth block and numbering of poles with black synthetic enamel paint in 2.5 cm height including tarring/Bituminous paint one coat on steel surface embedded in concrete foundation complete all as specified and shown on drawings and directed including taking down and dismantling old unserviceable steel tubular pole etc complete all as specified and directed. Note- Earthwork, PCC shall be measured and paid separately
Supply and fixing in repair flood light ,120 W,Outdoor type with high power LED's as light sources . Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing with dedicated heat sink and toughened glass with inbuilt control grar woth IP66,CCT :5700K,Efficacy : 100 Im/W,Impact resitace of IK07 and integrated driver with 5 KV inbuilt surge protection fixed on pole duly fixed on angle iron bracket complete including taking down existing unserviceable light fittings etc complete all as specified and directed.
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including three core copper wire and PVC conduit to connection light to Junction box and thermal management in multiple optics complete with IP 65/66 protection complete including taking down existing unserviceable light fittings etc complete all as specified and directed.
Supply and fix air ventilation fan matalic body 300mm, 900 RPM, single phase, 230V AC including necessary, Material and labour for making hole fixing arrangement on wall with frame holdfastner, bolt, washer etc including connection with twisted white three core flexible copper multistranded conductor cabl from ceiling rose to connector complete all as specified and directed.
Supply and Fixing Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 45 watt with efficiency 100 lumen/watt at system level, complete all as specified and directed, including street light GI pipe bracket & connection up to ceiling rose complete all as specified and directed.
Supply and fix LED Post Top Lantern 15 Watt with IP 65 protection, complete with necessary pcc foundation including taking down existing old pattern unserviceable light fitting complete all as specified and directed.
Supply and fix LED bollard type fitting 10 Watt cpacity 650 mm height, LED bollard AFlare fitted with low glare diffuser with IP 65 protection, complete with necessary pcc foundation including taking down existing old pattern unserviceable light fitting complete all as specified and directed.
Supply and fix junction box made of glass fibre reinforced and transparent poly carbonate of size 126x228x111, KV PC 8104 with IP 65 protection including MCB SP, 6 Amps 1 No and suitable size clamps fixing for pole/in pcc foundation etc,including taking down the old one, complete all as specified and directed. Make: Hensel
Supply, install, testing & Commissioning of Timer switch Timelite-65A 3Pole/230V-Digital Time Switch assembly, complete all as specified and directed.
Supply, installation, testing and commissioning of L.T Panel Supply, installation, testing & commissioning LT panel board, out-door type, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3 mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated , The cubicle shall have frame work, bottom & 40 CM long four legs of size 50 x 50 x 6 mm Angle iron, including suitable rating of aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and Control wiring with PVC insulated 1.5 Sqmm multi strand copper cable, complete comprising the following accessories (Note: The Panel shall be mounted on floor with PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above the ground level including dismantling existing unserviceable panel etc complete all as specified and directed. The cost of the PCC foundation shall be deemed to be included in the unit rate quoted for the item) (Note:- (i) LT Panel should be made/make of the manufacturer OEM of switch gear only (i) LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011,Test certificates for Shot Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 56KA. ( The contractor should submit all Certificates before executing the job.) Outdoor Floor mounting Incoming:-400 Amps 4P, On load change overswitch -01 Nos 400 Amps 4P,50KA MCCB -01 Nos - Multifunction Meter-01 Nos. - RYB Indication Lamp -01 Nos. - Copper bus bar of 500/515 rating Outgoing- - 160 Amp FP,25 KA MCCB - 02 Nos. - 125 Amp FP,25 KA MCCB- 02 Nos. - 100 Amp FP,16 KA MCCB- 01 Nos. - KWH Meter 3 Phase with CT measured up to the load 400 Amp- 01 Nos
Description all as per Ser item No 100 above but with following switch gears Outdoor Floor mounting Incomming - On Load Change over switch 320 Amps 4P - 01 Nos. - 320 Amps 4P, 36 KA MCCB- 01 Nos. - Multifunction Meter-01 Nos. - RYB Indication Lamp -01 Nos. - Copper bus bar of 500 rating Outgoing- - 125 Amp FP,25 KA MCCB - 02 Nos. - 100 Amp FP,25 KA MCCB- 02 Nos. - 63 Amp FP,16 KA MCCB- 01 Nos. - In built timer panel 63 Amp 3 Phase - KWH Meter 3 Phase with CT measured up to the load 320 Amp- 01 Nos
Description all as per item No 100 above but with following switch gears Incomming - 160 Amps 4P, 25 KA MCCB- 01 Nos. - Multifunction Meter-01 Nos. - RYB Indication Lamp -01 Nos. - Copper bus bar of 200 rating Outgoing- - 63 Amp FP,16 KA MCCB- 04 Nos. - 5/15 Amp Socket Out let- 02 Nos.
Material and labour for earthing complete for machinery equipment installed at power house/sub station with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to GI strip 32mm X 6mm main earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron and protected with 40mm dia medium grade GI pipe all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) 50mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 40mm dia GI medium grade earth lead protection pipe etc including taking down old/unserviceable earthing etc complete all as specified and directed. NOTE: (i) Earth strip and its protection pipe upto and including 7.5 mtr from the top of earth electrode are included under this item . (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. (iii) If the desired earth resistance is not found within permissible limit shall be re done by contractor at no extra cost.,.
Taking down carefully copper /aluminium point wiring (light, fan , socket or power ) any type including unscrewing from board,fitting and fixture such as switches, ceiling roses, holders, regulators sockets ,light fittings etc removing materials from site and making good disturbed with the existing surfaces complete all as specified and directed.
Material and labour for Point wiring with1100 Volts, grade 1.5 Sqmm. (nominal area) ,PVC insulated but unsheathed multistranded copper conductor single core FRLS cable drawn through and including non metallic medium duty rigid PVC concealed conduit (medium duty) 20mm dia or higher size complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including pressed iron/steel suction box of thickness1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly including cutting chases for conduits and sinking's for boxes and making good to walls,floors etc complete all as specified and directed of following
Description all as per item 105 above but with One bell point controlled by one-one way switch.
Description all as per item 105 above but with One fan point/light point controlled by one-one way switch through Regulator.
Description all as per item 105 above but with One three pin 5 Amp socket on same board with other switches.
Description all as per item 105 above but with One three pin 5 Amp socket on independent board.
Description all as per item 105 above but with 4 Sq.mm. (nominal area) cable for one 3 Pin 15 amp socket on independent board complete all as specified and directed.
Description all as per item 105 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 2.5 Sqmm complete all as specified and directed.
Description all as per item 105 above but up to Sheet matel enclosure MCB DB with plug socket independent, with cable 4 Sq mm size, with earth continuity coductor of size 4 Sq mm complete all as specified and directed.
Supply and fix Bell Push, button type 5 Amp SP 250V AC complete all as specified and directed.
Supply and fix switch piano flush, button type 5/6 Amp SP 250V AC complete all as specified and directed.
Supply and fix switch piano flush button type 15/16 Amps SP 250V AC complete all as specified and directed.
Supply and fix socket outlet 2-in-1, 5 Pin 5/6 Amps 250V AC complete all as specified and directed.
Supply and fix socket outlet 2-in1,3 pin 5 and 15/16 Amp flush type 250V AC complete all as specified and directed.
Supply and fix ceiling rose surface bakelite 3 terminals of size 65x25mm. complete all as specified and directed.
Supply and fix modular switch 1 way 6A,1 module,230 volts complete all as specified and directed.
Supply and fix modular socket 6A-2/3 pin, 2 module, 230 volts complete all as specified and directed.
Supply and fix modular socket combination 6/16 A,6 pin,2 module ,230 volts complete all as specified and directed.
Supply and fix modular Fan step regulator, 120W,2 module ,230 volts complete all as specified and directed.
Supply and fix Modular Bell push 6A 1 module complete all as specified and directed.
Supply and fix Bell Multi Music type single phase 230 Volt complete all as specified and directed.
Supply and fix modular white cover plate with frame,1 module ,230 volts complete all as specified and directed.
Supply and fix modular white cover plate with frame,3 module ,230 volts complete all as specified and directed.
Supply and fix modular white cover plate with frame,4 module ,230 volts complete all as specified and directed.
Supply and fix modular white cover plate with frame,6 module ,230 volts complete all as specified and directed.
Supply and fix modular white cover plate with frame, 8 module ,230 volts complete all as specified and directed.
Material and labour sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, conduit heavy duty accessories and fittings. Insulated unsheathed FRLS cable copper conductor multistranded of size 10 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified and directed. Note:-3 runs of 10 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
Supply and fix wall mounted LED tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed.
Supply and fix LED luminaries 600X600mm 35/36 watt ,220 volts AC Recessed type with high efficiency pmma diffuse soft glare free light complete with driver ,holder & LED lamp suitable for roof ceiling including connection , complete all as specified and directed.
Supply and fix LED light fitting decorative wall mounting SS brush finish fixture with 1x12 watt mini glass lamp with and including one no 12 watt LED lamp. complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix Sheet metal enclosure SPN with a two pin and earth plug and socket complete with one 240 Volts 20 amp single pole MCB complete all as specified and directed.
Supply and fix LED tube light along with fixture,16/18 W including taking down existing light fittings etc complete all as specified and directed.
Supply & fix LED bulk head 10 W including taking down existing light fittings etc complete all as specified and directed.
Supply and fix LED Tube light small 2 feet (Mirror light) fitting tube light alluminium extruded body with intergrated electronic driver along with fixture, 10 W including taking down existing light fittings etc complete all as specified and directed.
Supply and fix in repair calling bell single phase 230 Volt Ding Dong complete all as specified and directed.
Supply and fixing LED Solar street light fitting 12 Watt including hot dip galvanized octagonal pole 6m height with foundation bolt in built, lithium ion battery, solar panel, charge controller with dusk down sensor including taking down existing light fittings etc complete all as specified and directed. (Note:-Excavation & earth work shall be measured separately)
Supply and fix BLDC Ceiling Fan complete with electronic type regulator 230 V,1200 mm sweep. BEE 5 star rated PVC AC single Phase 230 V / 240V 50 Hz of , complete connecting up ceiling rose to connector block of fan including fabricating and fixing of Fan hooks from ceiling truss/angle iron, required length of down rods (Aas per site requirement) and necessary nuts and bolts etc including taking down existing fan and depositing to MES E/M-II store yard complete all as specified and directed.
Supply and fix Exhaust fan 150 mm PVC body made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block etc including taking down existing fan and depositing to MES E/M-II store yard complete all as specified and directed
Supply and fix Water heater storage type, electric, capacity 25 litres AC single phase 230/ 240 V o and connecting up including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block etc including taking down existing geyser and depositing to MES E/M-II store yard complete all as specified and directed.
Supply and fix Sheet metal enclosure SPN with a three pin and earth plug and socket complete with one 240 Volts 20 amp single pole MCB complete all as specified and directed.
Supply and fix VTPN DB 4 way 415 Volts, 50 Hz indoor type double door Sheet metal enclosure IP-43 DB's flush mounted with 250 Amp Copper busbar for each phase with two neutral bar & two earthbar and cable ties for cable managenment including mounting arrangement for DPX3 MCCB 160 Amps four pole 415 volts as incomer including connection terminal strip complete pre wired with suitable size copper conductor. The DB's should hold type test certificate (CPRI) as per IEC 61439-3 and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed
Supply and fix sheet metal enclosures TPN 415 Volt 4 way with suitable rated bus bar for Single door IP-43DB's and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed
Supply and fix sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed
Supply, installation, testing of SPN distibution board 4 way,double door , IP 43, as per IS 8623 including 100 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed.
Supply and fix MCB TPN 415 Volt 10 KA 63 Amp conforming to IS cincluding connection with suitable size copper lugs complete all as specified and directed.
Supply and fix MCB SPN 240 Volt 10 KA 40 Amp conforming to IS including connection with suitable size copper lugs complete all as specified and directed.
Supply and fix MCB SP(single pole) 240 volt 10 KA 6 to 40 Amp, conforming to relevant IS including connection with suitable size copper lugs complete all as specified and directed.
Material and labour for submain wiring with 3 runs(1 run for Phase+1 run for Neutral &1 run for Earth) of 4 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 volts grade drawn through and including concealed wiring with PVC conduit pipe of medium duty not less than 20 mm dia including necessary steel conduit specials and connecting with suitable size thimble, and making good surface of disturbed wall/ceiling/floor as match with existing including taking down existing sumain wiring etc complete all as specified and directed. Note:-3 runs of 4 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
Description all as per item No 151 above, but 3 run (2 run for Phase and one run for Earth) of 6 Sqmm copper comnductor as earth wire. Note:-3 runs of 6 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length complete all as specified and directed.
Description all as per item No 151 above but submain wiring with 6 runs (3run for Phase, 1 run for neutral & 2 run for earth with approved colour) of 10 Sqmm single core, drawn through and including concealed/Surface PVC conduit pipe of medium duty not less than 32 mm dia including necessary PVC conduit specials and connecting with suitable size thimble complete all as specified and directed. Note:-6 runs of 10 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with a 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00mm dia by means of bolts, nuts, Check nuts and washers of galvanised iron and thimbles and other end of the earth wire all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board and protected by galvanized iron pipe medium 15 mm bore, and water pipe 20 mm bore GI light grade with funnel and wire mesh, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) 50mm thick cover, reinforced with 8mm dia deformed or TMT bars 100mm C/C both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. NOTE: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. (iii) If the desired earth resistance is not found within permissible limit shall be re done by contractor at no extra cost.
Supply, install, test and commisssioning reversible type (Hot and cool) split air conditioning unit 1.5 Ton, 3 star, eco friendly refrigerant complete with drive motor, air cooled copper condenser with all accessories varied speed and dual rotary compressor, including fixing the out door units with mounting bracket , made Up of heavy duty GI steel, wall mounted type, Powder coated incl nuts & bolt etc as per manufacture recomendation and fixing of room unit on wall , providing and making interconnection , including refregerent piping with nitryle rubber insulation and control cable from indoor to out door , first charging of refrigerent gas including cordless remote and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90V to 300V with output voltage stailized at 230V with accuracy of + 2.5% and of capacity 03KVA.
Supply, fixing & connecting wall mounted fan oscillating type 400mm sweep single phase 230 Volt complete all as specified and directed.
Supply and fix Geyser vertical mount type 25 Ltrs capacity five star rated , shockproof and rust proof metal body compact size including two nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified & directed .
Supply only integral waterproofing compound complete all as specified and directed.
Note :- Amount of credit of Rs. 61863.00 for retrieved materials is mentioned in Schedule of Credit Page No 36 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Pragati Enterprises (BID ID -3309558)
M/s Pradeep Kumar (BID ID -3309818)
V S ENTERPRISES (BID ID -3307813)
V r traders (BID ID -3307923)
Mahamaya Engineers Services (BID ID -3310059)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .