Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC | L1 | Accepted-AOC Award of Contract | |
| 2 | L2₹2.4 L+₹4,426 (1.86%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹2.5 L+₹11,883 (4.99%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹2.7 L+₹29,488 (12.4%)Rejected-Finance 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹3.5 L+₹1.1 L (46.6%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
26 Jul 2023, 6:00 pmClosed
AGE(I) Dharamshala
AGE(I) Dharamshala PIN-176216
Repair/replacement of geysers, ceiling fans, exhaust fans, summer appliances and other connected works at Charri Camp at Mil Stn Dharamshala
2023_MES_606593_1
AGE(I)/DSL-27/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE(I) Dharamshala
As per NIT
7 documents required · 7 mandatory
₹500
AGE(I) Dharamshala
₹10,000
Yes
12 Sept 2023
28 Jun 2023
2 Aug 2023
28 Jun 2023
26 Jul 2023
12 Jul 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed by Engr-in-Charge.
M&L for point wiring with 1.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheating FRLS electric cable 1100 volts cable in and including PVC casing and caping of suitable size (as per conductor run) with all fittings such as bend/corners/ accessories and including PVC insulated electric cable 1100 volts 1.5 Sqmm (multi-stranded) copper conductor single core (Green colour) cable as continuous earth wire connected to common earth dolly in existing CI/wooden box covered with 3 mm thick plastic laminated sheet for one light point/ fan/exhaust fan point/ bell point etc controlled by one, one way switch, complete all as specified and as directed by the Engr-in-Charge. Note : i) New Sunken boxes wherever required shall be measured paid separately. ii) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost.
All as per serial item No 2 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly, complete all as specified and as directed by the Engr-in-Charge.
M&L for switch socket combination 2 in 1, 5 Amp and 15 Amp flush type, complete all as specified and as directed by the Engr-in-Charge.
M&L for switch piano flush type single pole one way 5/6 Amp, complete all as specified and as directed by the Engr-in-Charge.
M&L for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block, complete all as specified and as directed by the Engr-in-Charge.
Taking down exhaust fans 250/ 300/ 380/ 450 mm sweep, and then properly cleaning and greasing of bearings after opening of the fan including replacement of unserviceable parts, reassembling and reconnecting of exhaust, complete all as specified and as directed by the Engr-in-Charge. Note: Spare parts shall be measured and paid separately at 'supply only rates'.
Supply only ball bearing of exhaust fans of any size and type all as per site requirement including greasing, complete all as specified and directed by Engr-in-Charge. Make: SKF/NBC/ABC
M&L for rewinding of exhaust fan of 225 to 300 mm sweep complete with super enameled insulated copper wire of appropriate size, including all winding, insulating material and impregnation of insulating varnish of any make, type, model including transportation from AGE E/M store yard to site after rewinding, complete all as specified and directed by Engr-in-Charge.
All as per item No. 9 above but exhaust fan of 450 mm sweep, complete all as specified and directed by Engr-in-Charge.
Painting of exhaust fans after due preparation of surface 225/300/380/ 450 mm sweep complete at site with super enamel synthetic paint of colour as per old one by spray gun including filling cavities with filler, two coats after cleaning all dust, grease, smoke spots etc, complete all as specified and directed by Engr-in-Charge.
Supply only copper alloy bush of exhaust fan any make and size all as per site requirement, complete all as specified and directed by Engr-in-Charge.
Supply only deshaped blade from exhaust fan of any size, complete all as specified and directed by Engr-in-Charge.
Taking down ceiling fans 1200/1400mm sweep, and then properly cleaning and greasing of bearings after opening of the fan including replacement of unserviceable parts, reassembling and reconnecting of and also writing MES No. existing with black paint, complete all as specified and directed by Engr-in-Charge. Note: Spare parts will be measured and paid separately at 'supply only rates.
Strip opening of unserviceable ceiling fan 230 volts 1200/1400 mm sweep any make for undertaking repairs/greasing /oiling, reassembling and testing after repairs/greasing etc, complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of ceiling fan motor 1200 mm sweep any make with super enameled copper winding wire of gauge as per existing including cutting and getting out old US winding, sleeve work, varnishing with E class insulation varnish , threading ,connections with twin core copper flexible wire of size 0.0076mm of length not more than one mtr with each fan, complete all as specified and directed by Engr-in-Charge. Note: (i) Fixing of repaired fan in any location of cantt area shall be contractors responsibility at his own arrangement of transport and T&P. (ii) Old burnt wire shall be contractors property and necessary credit shall be recovered as per sch of credit attached .
Supply only ball bearing of ceiling fans of any size and type all as per site requirement including greasing, complete all as specified and directed by Engr-in-Charge. Make: SKF/NBC/ABC
Supply only gun metal copper alloy bush for ceiling fan any type and size as per existing one, complete all as specified and directed by Engr-in-Charge.
Supply only capacitor of size 2.5 MFD for ceiling fan, complete all as specified and directed by Engr-in-Charge.
supply only canopy of ceiling fan of size and make as per existing one as required at site, complete all as specified and directed by Engr-in-Charge.
Supply only down rod of ceiling fan with heavy grade of 15mm size pipe complete with drilling holes,cutting and making threads as per site requirement up to 0.75mtr ,painting with two coats of white paint, complete all as specified and directed by Engr-in-Charge.
Supply only bolts,nuts and washers,rubber reel, split pin of appropriate size as required at site for ceiling fan of any size, complete all as specified and directed by Engr-in-Charge.
Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc, complete all as specified and directed by Engr-in-Charge.
Supply only of ceiling fan blade suitable for 1200mm/1400 mm sweep, complete all as specified and directed by Engr-in-Charge. Make: Bajaj/USHA/CG
Taking down carefully from wall after unscrewing nut/bolts geyser 50/35/25 Ltr capacity and opening the same for taking out internal tank, syphon assembley etc and reassembling and refixing after repair, complete all as specified and directed by Engr-in-Charge. Note: Spares shall me measured and paid sepratley under respective items of Sch.
Supply only heating unit (element) ISI marked of 1500 watts triangular shape rating as required at site including rubber washers, complete all as specified and directed by Engr-in-Charge. (As per sample) Make: Umpire/Wondercool/Ditz/ Toshiba
All as per Serial item No 26 above but circular shape, complete all as specified and directed by Engr-in-Charge. Make: Umpire/Wondercool/Ditz/ Toshiba
Supply and replacement internal steel tank of geyser 25 ltr capacity complete with syphon assembly, 1.5 kw element , rubber gasket , thermostat switch. The tank shall be tested at site and shall be able to with stand the requisite pressure. Necessary testing equipment shall be arranged by the contractor, complete all as specified and directed by Engr-in-Charge.
Supply and replacement internal steel tank of geyser 50 ltr capacity complete with syphon assembly, 1.5 kw element , rubber gasket , thermostat switch. The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of syphon assembly made out of brass of 50 ltr capacity including necessary studs screws and rubber gasket/washers, complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 30 above but 25 ltr capacity, complete all as specified and directed by Engr-in-Charge.
Supply and replace glass wool of 25 ltrs capacity geyser, complete all as specified and directed by Engr-in-Charge.
All as per sl item 32 here in before but 50 ltrs capacity geyser, complete all as specified and directed by Engr-in-Charge.
De-scaling of geyser of capacity 25/50 ltr after taking down the geyser from wall, strip opening the assembly, de-scaling the syphon assembly and refixing the assembly and re-installation of geyser, complete all as specified and directed by Engr-in-Charge.
Supply and replace PVC connection 15mm dia complete with brass flair nuts at both ends, complete all as specified and directed by Engr-in-Charge. Make: ISI marked and suitable for hot water supply upto 100 degree celcius.
Supply and replace brass pressure relief valve chromium plated suitable for geyser 25/50 ltr capacity, complete all as specified and directed by Engr-in-Charge.
Supply and fixing anchor bolt 12mmX100mm long, complete all as specified and directed by Engr-in-Charge. Note: Anchor bolt shall be grouted with hammer drill only.
Supply and replacement of defective mild steel base plate cup any type with screws of suitable size as per requirement, complete all as specified and directed by Engr-in-Charge.
Supply only ISI marked thermostat range 0°-75°C for the geysers of 25 to 50 Liters capacities, complete all as specified and directed by Engr-in-Charge.
Supply for 15mm stop valve CP fancy type,cast copper alloy,screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe unions and suitable, complete all as specified and directed by Engr-in-Charge.
Supply only non return valve 15mm dia cast copper alloy ISI mark, complete all as specified and as directed by Engn-in-charge.
Supply only Indicator lamp rectangular/round type, complete all as specified and directed by Engr-in-Charge.
Supply and replace CP connection brass with flair nuts, complete all as specified and directed by Engr-in-Charge.
Supply only GI union 15mm dia complete for fixing non return valve, complete all as specified and directed by Engr-in-Charge.
Cleaning/scrapping of old paint/dust and painting of geysers of 25/35/50 litres capacity at site/ stores with two coat of super enameled painting by spray, complete all as specified and directed by Engr-in-Charge.
Supply and fixing mild steel galvanised iron water tubing 15mm bore with screwed & socket joints, medium grade, in short lenghts, with and including all fittings such as sockets,bends,elbow,unions,tees diminishing pieces etc fixed to wall or ceiling or in floor, complete all as specified and directed by Engr-in-Charge.
Supply and fixing sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar, including taking down the existing and making good distrubed surface, complete all as specified and directed by Engr-in-Charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of current carrying capacity SP 5 to 32 Amp MCB complete all as specified and directed by Engr-in-Charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of current carrying capacity SPN 32 Amp MCB complete all as specified and directed by Engr-in-Charge.
Supply and fixing plug top 15 Amp three pin for geysers, complete all as specified and directed by Engr-in-Charge.
Supply and fixing metal clad socket three pin for geysers, complete all as specified and directed by Engr-in-Charge.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 10sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apartincluding 4mm suspension wire, one twin core cable flat or circular, complete all as specified and directed by Engr-in-Charge.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of existing UNSV sealed unit for Refrigerator of any capacity including Gas charging, complete all as specified and directed by Engr-in-Charge.
M&L for charging oil and R-134A gas for refrigerator in various sizes and capacities after rectifying leakage and testing, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of cooling coil for refrigerator of various capacities and makes, complete all as specified and directed by Engr-in-Charge.
Supply and fix magnetic door gasket for refrigerator of various makes and capacities, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of OLP suitable for refrigerator of various capacities, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of Starting relay for refrigerator of capacity 165 to 310 ltrs capacity of various makes, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of biometal timer for frostfree refrigerator, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of fan motor for frostfree refrigerators, complete all as specified and directed by Engr-in-Charge.
Removing of water cooler of various sizes from the room, servicing with HCL acid and water solution and refixing the same on its original position with insulating complete all as specified and directed by Engr-in-Charge.
S&F in replacement of existing UNSV cooling Thermostat switch No 10180 for Refrigerator of any type, complete all as specified and directed by Engr-in-Charge.
Supply and install voltage stablizer of capacity 0.5 KVA, complete all as specified and directed by Engr-in-Charge. Make-:V-Guard/Kelvinator/Godrej
Supply and fixing LED bldg security light 15 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed by Engr-in-Charge.
M/S SAROOP ELECTRICAL & MECHANICAL WORKS
M/S MALHI CONSTRUCTIONS
VIRAT CONSTRUCTIONS
Mahashakti Enterprises
Eshaan Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .