Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC | L1 | Accepted-AOC CA No. GE (AF)/ TVM/ 42 OF 2020 - 2021 | |
| 2 | L2₹26.8 L+₹6.0 L (28.9%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted |
Tender Value
Refer Docs
EMD Value
₹37,800
Closing Date
14 Jan 2021, 6:00 pmClosed
GE AF Trivandrum
Office of Garrison Engineer AF, Pulayanarkotta, Thuruvikkal Post, Trivandrum-11
ADDITION ALTERATION TO POSITION OF BLDG NO P 34 SPECIAL REPAIR REPLACEMENT OF BER CEILING FANS AND BATTERIES OF 30 KVA UPS AND E M MINOR WORKS AT 17 FBSU HQ SAC 257 SU UNDER GE AF TVPM
2020_MES_403401_1
GE AF TVM/ 8283
Open Tender
Civil Works
Item Rate
180 days
Trivandrum
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TRIVANDRUM
₹37,800
Yes
5 Feb 2021
14 Dec 2020
16 Jan 2021
14 Dec 2020
14 Jan 2021
28 Dec 2020
Amount
SCHEDULE 'A'
Demolition of cement Concrete (unreinforced) in ground floors and pavings n exc. 15 cm thickness (below or above ground level) completed all as specified and as directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed
Dismantling Prelaminated particle, board, exterior grade, prelaminated one side with decorative choice laminations & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed
Taking out old serviceable glass of any description, from old wooden or metal frames, or stone, concrete or brick surrounds, any thickness or size; hacking out old putty or removing beads etc. including making good breakages in taking out and handing removing to store or stacking for reuse complete all as specified and directed .
M & L Dismanling wrought iron or mild steel work of any description not otherwise provided for . Rate inclusive of scaffoldings for working platform at any height above GL complete all as specified and directed .
Dismantling Old Aluminium partition with door etc complete all as specified and directed
M&L 25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in sub floor under tiles, all as specified and directed.
M & L for 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
M/L 10 mm thick plastering in cement mortar 1:4 as backing coat for receiving finishes as skirting /dado.complete all as specified and directed
S & F coloured Non skid ceramic tiles 7 to 8mm thick (square /Rectangular ) area of each tile exc 0.18 sqm and n.exc 0.38 sqm ,in floors etc set and jointed in neat cement slurry and pointed with coloured cement to match with the shade of the tiles all as specified and as directed by Engineer-in-Charge.
All as per above item No.12 but skirting complete all as specified and directed by Engineer in charge.
Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified and directed
Forming jambs, etc., to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete in CM 1:4 complete all as specified and directed by Engineer in charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for flat rough finished surfaces of concrete complete all as specified and directed by Engineer in charge.
M & L for reinforced cement Concrete Type B1 (1:2:4) using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by EIC.
M&L for TMT bars 10 mm dia and over cut to length or bent to shape required cranking, bending spirally for hooping for columns, hooking ends and binding with and incluidng mild steel wire (anealed) not less than 0.9 mm dia or securing with clips quality confirming complete all as specified and directed by Engineer in charge.
All as per above item No.18 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by Engineer in charge.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar 1:4 on fair face of brick work or concrete surfaces finished even and smooth complete all as specified and directed.
M & L designed rendering 20 mm thick on fair faces of brick work or concrete surfaces in CM (1:4) complete all as specified and directed by Engineer in charge.
M&L for preparation of new plastered wall surface and applying two coats of plastic emulsion paint over a coat of priming paint complete all as specified and directed.
M&L for preparation of new plastered ceiling surface and applying two coats of plastic emulsion paint over a coat of priming paint complete all as specified and directed.
M&L for preparationn of old ceiling surface and applying two coats of plastic emulsion paint over a coat of priming paint complete all as specified and directed.
M&L for preparationn of old wall surface and applying two coats of plastic emulsion paint over a coat of priming paint complete all as specified and directed.
S&F Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer-in-Charge.
S & F powder coated aluminium door shutters, aluminium sections weghing 0.55 Kg/m including necessary joining cleats glazing clips, rubber neoprene packing, handles 2 Nos each door, hinges anodised aluminium snapbeading screws etc. in two panels with locking system, with one or more rebates including joining cleats for fixing etc complete all as specified and as directed by Engineer-in-Charge.
S&F 5.5 mm thick sheet glass ordinary quality in square or rectangular of any description and fixed to aluminium framed work complete all as specified and directed.
M & L 12 mm thick prelaminatd particle board, interior grade, prelaminated both sides with decorative choice laminations, fixed to aluminium frame work complete all as specified and directed.
S & F brass 4 lever mortice lock, vertical type 100 mm size complete all as specified and directed.
S & F of door closer, aluminium body, hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
S&F 12mm thick tempered toughened glass as in shelf fixed to wall/ceiling/floor including clips or fixing with adhesive complete all as specified and directed.
M&L for 10mm thick wall cladding tiles of any size, design, shape as approved by Engr-in-Charge, set and jointed in neat cement slurry and pointed in white or coloured cement including two coats of silicone based water repellent paint complete all as specified and directed.
M & L for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate channel at 457mm centre to centre complete all as specified and directed.
S & F of Gypsum Board 12mm thick in ceiling fixed with screw as per manufactures instructions including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape. complete all as specified and directed
M&L for 3mm thick wall care putty on ceiling complete all as specified and directed.
M&L for 3mm thick wall care putty on wall complete all as specified and directed.
S&F second class hardwood plain fillets, square or rectangular in section, clean sawn, secured with nails area exc. 13 sq cm and not exc. 25 Sqcm complete all as specified and directed by Engg-in- Charge
M&L for french polishing on new surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats complete all as specified and directed.
M&L for 18/19 mm thick Prelaminated LMDF particle board, exterior grade decorative choice boards for both sides fixed with screws and painting to lipping protion to match with lamination as cupboards, drawers, cupboard shutter etc. complete all as specified and directed by Engg-in- Charge.
Complete removal of existing treatment on walls/ceiling surface complete all as specified and directed by Engineer in charge.
M & L for preparation of old surfaces and applying two coats of texture painting of any pattern as approved by GE over a coat of priming paint complete all as specified and directed.
Supply and fix new energy efficient down light with efficiancy of 100 lm/W designed to replace CFL luminaire solutions of capacity 12 watt and driver complete all as specified and directed . Make : Havells Cat No Endura HO Cat Part No ENDURAHODLR12WLED840MOD + DRIVER CAT PART NO LEDDRIVER12/15WENDURAHOCE or equivalent in Philips/Wipro
M&L for point surface/concealed wiring complete with 1.5 Sqmm 1100 volts grade single core FRLSH PVC insulated sheathed cable with multi strandard copper conductor drawn through by PVC conduit medium grade of suitable size on walls/ ceiling etc and including provn of 1.5 sqmm PVC insulated copper cable as earth continuity conductor fabricated branded Modular suitable plate with cover for housing switches socket outlets fan regulators etc and as directed for the following :- Note : Rate for cutting of chases for fixing of PVC conduits and its accessories including making good the disturbed surfaces of walls/floors etc with the existing deemed to be included in the item rate
S&F Modular switch 1 way 6 A, 1 module complete all as specified and directed
M&L for sub main wiring surface/ concealed type including cutting chases and making good in CM 1:3 complete with (2 runs of 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth continuity) 1100 Volts grade PVC insulated unsheathed single core multistranded cable FRLSH grade with copper conductor drawn in conduit including provision of 25 mm dia PVC rigid conduit (medium grade) with conduit accessories such as bends, elbows, saddles complete all as specified and directed
S & F SPN 8 way of double door with suitable busbar including disconnecting from mains and making good the disturbed surfaces complete all as specified and directed .
Supply and fix MCB SP 6A - 32A complete all as specified and directed
Supply and fix MCB SPN 6A -32A complete all as specified and directed
M & L for removing split type AC of 1.5 ton capacity from existing location after pumping down gas and refixing at new location including charging of gas and servicing complete all as specified and directed.
Supply and fix of new copper pipes of additional length, and fixing complete all as specified and directed.
Supply and fix metal plug and socket, single pole, two pin and earth plug with one single pole MCB 20 Amps capacity and steel enclosure complete all as specified and directed.
S & F in MS bracket for fixing outer unit of Air conditioners of 1.5 ton capacity complete all as specified and directed.
Taking down unserviceable Batteries of 30 KVA UPS after disconnnecting all the connections from UPS complete all as specified and directed.
S & F of sealed lead Acid Battery 12 V / 65 AH with initial charging and making necessary inerconnection and connected to Existing UPS 30 KVA complete including testing and commissioning all as directed by engineer-in-charge.
Supply, installing, testing and commissioning outdoor type LT panel board cubical type, platform mounted, factory made, totally enclosed, dust & vermin proof, made of 3.15 mm CRCA sheet, MS flat & angle supports/ frames, duly fabricated and fitted on PCC platform having proper locking arrangement in front with powder coated paint both internally and externally suitable for 415 volts, 50 Hz, 3 phase, 4 wire system and comprising of the followings features and independent compartment in front door position for MCCBs/ MCBs and accessories / components, including connecting existing LT cable to new LT Panel with required length of cable, lugs and Glands complete all as specified.
Taking out old unserviceable UG cables of any size from ground/floor/wall complete all as specified.
Supply laying testing of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 V grade with stranded aluminium conductor including necessary glands, lugs etc of size 16 Sqmm 4 core fixed on wall/ through pipe / Trenches all as directed
Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out complete all as specified.
Returning and refilling of excavated soil up to a depth of 30 cm after riddling the excavated soil for Cushing of cable and refilling of trench with normal excavated soil all as specified and directed
Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point.
M&L for cutting bituminous road/PCC had standing for laying of UG cable ,not exceeding 30 cm in width and 45 cm in depth and making good the disturbed surfaces as per the existing complete all as specified and directed
M&L for GI pipe 40 mm dia light grade laid in trenches at road crossing/foot paths complete all as specified and directed
Supply and install testing , commissioning of Split AC with inverter type comprising of indoor/outdoor with copper coil single phase 230 v 50 Hz complete with cordless remote control unit including necessary fixing arrangement complete unit shall be placed at suitable position and height inside the room and outdoor unit at suitable place outside the room on plinth height/ on wall or roof as suitable and including metallic bracket with fixing bolts for outdoor unit, insulated copper piping at required lenghth at site, Refrigerent R 32 of capacity 2.0 TR ( copper type) 5 star rated complete all as specified and directed. Make: Voltas / Bluestar /Hitachi
Supply & Fix metal plug and socket single phase two pin and earth plug with MCB, SP 25 Amps and steel enclosure all as directed.
M&L for sub main wiring surface type including with (2 runs of 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth continuity) 1100 Volts grade PVC insulated unsheathed single core multistranded cable FRLSH grade with copper conductor confirming to IS 694 drawn in conduit including provision of suitable dia of PVC rigid conduit (medium grade) with conduit accessories such as bends, elbows, saddles all as specified and as directed.
Supply and fix voltage stabilzer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 270V with output voltage stabilised at 230 V with accuracy of ± 12 % and of capacity 5 KVA with time delay and under voltage/over voltage cutoff all as specified and directed.
Supply, installation, testing and commissioning of maintenance free grounding solution set comprising of High tensile low carbon steel rod of 3 mtr lengith and 17.2 mm dia with 250 micron (average) molecularly bounded copper on the outer surface to confirm with requirements of UL 467 including suitable copper earth termination clamp alongwith back fill compound of 44.6 Kgs strictly be a carbon based conductive concrete type which has a fixed carbon content of more than 99 % and resistivity of less than 0.12 Ohm Mtr as per clause 14.5 D of IEEE, 80 standard back fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction, size of bore 80 mm dia, complete all as specified and directed. Make : JEF Eco safe earthing or equivalent, including earth pit cover made of heavy duty polyplastic and earth inspection cover made of high grade polypropylene of size top dia not less than 250mm, bottom dia not less than 330mm dia and height not less than 260mm having load bearing capacity not less than 8 tonnes for each electrode etc, complete all as directed.
Supply and fixing copper strip 25 x 3mm thick as earthing lead fixed to wall/roofs etc all as directed.
Taking down old unserviceable ceiling fan complete all as directed.
Taking down old unserviceable exhaust fan complete all as directed
Supply & fix ceiling fan BEE 5 star rated complete with all accessories 230 V, 50 Hz 1200 mm sweep complete all as specified and directed by Engineer-in- Charge. .
S & F Exhaust Fan 380 mm Sweep 1400 RPM Heavy Duty 230 V 50 Hz AC complete with all accessories complete all as specified and directed. Make Turboforce SP of Havells or equivalant make in bajaj/ Crompton
Supply and install testing, commissioning of split ACs with inverter type comprising of indoor/outdoor with copper coil single phase 230V, 50Hz complete with cordless remote control unit of high EER rated BLDC compresor, including necessary fixing arrangement complete unit shall be placed at suitable position and height inside the room and outdoor unit at suitable place outside the room on plinth height / on wall or roof as suitable and including metallic bracket with fixing bolts for outdoor unit, insulated copper piping at required length at site, , Refrigerant R 32 of cpapcity 1.5TR (copper type) 5 star rated complete all as specified and directed. Make : VOLTAS Model No 185 V SZS(R 32) , Blue Star Model No IC 518 DATU, Hitachi Model No Kashikoi 5300 X ( RSOG518ICEA)
Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.00 KVA complete all as specified and directed. Make V-Guard VWI 400.//Microtek/Aplab
Supply & Fix metal plug and socket single phase two pin and earth plug with MCB, SP 20 Amps and steel enclosure all as directed. Make - Anchor/Havells/Legrand
M&L for submain wiring with PVC insulated unsheathed 1100 volts graded multi stranded copper conductor FRLSH cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit with all accessories fixed to wall/roof/ceiling/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100volt grade for earth continuity conductor and connected to common earth. Note :- 2 runs of 4 Sqmm cable alongwith one run of 4 sqmm cable for earth conductor and PVC conduit shall be measured as one length.
M&L for point wiring with 1.5 Sqmm single core PVC insulated FRLSH cable 1100 volts grade with multistranded copper conductor drawn in and including PVC conduit and all conduit accessories (concealed) and including provision of 1.5 Sq mm PVC insulated copper cable FRLSH ISI marked as earth continuity conductor fabricated branded Modular metal flush box concealed in walls with Modular suitable plate with cover with suitable screws for housing switches socket outlets fan regulators etc all as specified and directed.
S&F switch flame proof rotary type with termination box in LM6, 16A, single pole 250 V all as specified and directed.
Supply and fix flame proof weather proof tube light 1 x 20 W flame proof type FLP-WP made of aluminium alloy LM6 complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with metal flexible hose of suitable size all as specified and directed Make :Sudhir or equivalent
Sub Total of Schedule 'A'
SCHEDULE OF CREDIT
Schedule of Credit (Minus) Rs. 22,950.00 B/F from Ser page No.118(R). NOTE: Bidder shall insert credit amount as rate Rs. 22,950.00 in Green field under Col-5.
Sub Total of Schedule of Credit
AKASH CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .