Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹16.8 L Quoted ₹17.5 L | L1 | Accepted-AOC Lowest bid |
| 2 | L2₹18.0 L+₹51,012.50 (2.91%)Rejected-Finance PMC 24 528 GROUND FLOOR NEAR PAYYANUR SERVICE CO OP BANK KOTTY BRANCH PAYANNUR KANNUR KERALA 670307 | PAYYANUR | KANNUR | KERALA | 670307 | ₹18.0 L+₹51,012.50 (2.91%) | L2 | Rejected-Finance Higher bid value |
| 3 | L3₹21.0 L+₹3.5 L (20.3%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | ₹21.0 L+₹3.5 L (20.3%) | L3 | Rejected-Finance Higher bid value |
| 4 | L4₹21.3 L+₹3.8 L (21.8%)Rejected-Finance THEKKEKOTTARAM RAMANTHALI PO KANNUR DIST KERALA 670 308 | RAMANTHALI | KANNUR | KERALA | 670308 | ₹21.3 L+₹3.8 L (21.8%) | L4 | Rejected-Finance Higher bid value |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
3 Dec 2019, 6:00 pmClosed
GE MAINT EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA
AUGMENTATN/IMPENT TO KITCHEN CABINETS IN OFFRS ACCN, DEMOLITION OF OLD VINTAGE BLDG NO. V-127, PROVN OF POWER SOCKETS AT KATARI CDTS MESS AND PROVN OF EARTHING IN ECE LABS IN P-153/C-6 ETC UNDER AGE B/R I (MAINT) AND AGE E/M (MAINT) AT INA EZHIMALA
2019_MES_296380_1
GE MAINT EZHIMALA 8271 E8
Open Tender
Civil Works
Item Rate
270 days
EZHIMALA
As per NIT
7 documents required · 7 mandatory
₹500
GE MAINT EZHIMALA
₹36,000
Yes
3 Jan 2020
9 Nov 2019
5 Dec 2019
9 Nov 2019
3 Dec 2019
25 Nov 2019
11 Nov 2019 - 23 Nov 2019
Amount
Dismantling boarding, any description, fixed with screws complete as specified and as directed.
S&F Aluminium Composite Panel 4mm thick of approved colour and shade of Alu Bond or equivalent fixed with self tapping screws on aluminium powder coated frame work weight not less than 0.55 Kg/Rm in any shape and size complete as specified and directed by Engineer-in-Charge.
S&F Anodised powder coated aluminium frame for Kitchen cupboard with one or more rebates including joining cleat for fixing etc. complete as specified and directed.
M&L for 1st class hard wood Plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or brads. exc 3 & n exc 6 sq.cm complete as specified and directed.
M&L for 19 mm thick Block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work as in kitchen cabinet including fixed on wall by drilling and bolting etc complete as specified and directed.
M&L for 1.5 mm thick Decorative laminates type I, or surface finish, colour and pattern as approved complete as specified and directed.
M& L for Two coats French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works complete as specified and directed.
M&L preparation of new painted surfaces exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of primer on wooden surfaces complete as specified and directed.
M&L for Extra over rates of block board or veneered particle board for external teak wood lipping, 6mm thick fixed with nails complete as specified and directed.
S&F Nickel plated Auto closing concealed Hydraullic Hinges with two holes for cabinet doors complete as specified and directed.
S&F 75mm stainless steel handles, cast type, polished for cupboard shutters, etc. complete as specified and directed.
S&F 50mm stainless steel butt Hinges, cast type, polished for cupboard shutters, etc. complete as specified and directed.
S&F 50mm stainless steel tower bolt , cast type, polished for cupboard shutters, etc. complete as specified and directed.
M& L 19 mm thick Block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work as in drawers complete as specified and directed.
S& F Mild steel drawer slides complete all as per manufacturer instructions and as specified.
Extra over rate for Forming groove of uniform size 10mm wide and 10mm deep in wooden batten for cupboard shutters complete as specified and directed.
Taking down Chowkhats with shutters (without taking off the shutters from the frames) of area not Exc. 1.5 Sqm each complete as specified and directed.
Taking down Chowkhats with shutters (without taking off the shutters from the frames) of area exc. 1.5 Sqm and not Exc. 4 Sqm each complete as specified and directed.
Dismantling single layer of Mangalore pattern tiles in roofing complete as specified and directed.
Demolition of stone masonry built in cement mortar including all quoins, arches etc complete as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above GL) including ceramic tiles complete as specified and directed
Dismantling timber scantlings 40 Sqcm and over in section, in any position, unframed work complete as specified and directed.
Dismantling timber scantlings 40 Sqcm and over in section, in any position, framed work complete as specified and directed.
Dismantling timber as in fillets, rails, rafter, purlins etc under 40 Sqcm in section unframed work complete as specified and directed.
Removing demolished materials to a distance of exc 1.50 km but not Exc. 5 km and deposited where as directed including loading, unloading and stacking at the destination.
Material and labour for colour code point wiring FR PVC insulated and unsheathed cable with 2.5 Sqmm copper conductor single core multistrand 1100 Volt grade confirming to IS 694 drawn through PVC cassing and capping of size 20/25mm , Junction boxes, suitable size PVC box for 3 pin socket outlet 6/16 A independent board including 2.5 Sqmm earth wire copper insulated wire connected to common earth dolly complete as specified and directed.
S&F Modular switch one way 16A ,1 module complete as specified and directed
S&F modular white cover plate with frame 3 module complete as specified and directed.
S&F modular socket 16Amps 2/3 pin2 module complete as specified and directed
M&L for submain wiring complete with 2 x 4 Sqmm + 1 x 4 Sqmm earth wire PVC insulated and unsheathed cable with multistranded copper conductor in PVC Casing caping complete as specified and directed. Note : 3 Runs of PVC copper cable of size 4sqmm and 1 Run of PVC casing caping will be measured as one runninng mtr.
M&L for submain wiring along with earth wire of FR PVC insulated copper conductor cable single core of 4 run 4 sqmm and 1x4sqmm earth wire in casing caping of suitable size complete as specified and directed. Note : 5 Runs of PVC copper cable of size 4sqmm and 1 Run of PVC casing caping will be measured as one runninng mtr.
S&F MCCB DB TPN 415V double door type4way with 125 A MCCBbusbar of appropriate current carrying capacity,neutral link and din rail complete as specified and directed.
Supply and fix MCB DB TPN 415 double door type4way with busbar of appropriate current carrying capacity,neutral link and din rail complete as specified and directed.
Supply and fix MCB TPN 63 A complete as specified and directed.
Supply and fix MCB TP 63 A complete as specified and directed.
Supply and fix MCB TP 32A complete as specified and directed.
Supply and fix MCB TPN 32A complete as specified and directed.
Supply and Fix MCB SP 32A complete as specified and directed.
Supply and fix MCB SP 20A complete as specified and directed.
Supply and fix Sheet metal enclosure 32A with five pin plug and socket complete with and including one four pole 32Amp MCB complete as specified and directed.
Supply and fix Sheet metal enclosure 32A with three pin plug and socket complete with and including one double pole 32Amp MCB complete as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600mm x6mm thick buried directly in ground verticaly to a depth not less than 2.25m deep below the normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised earth wire of size 4mm dia by means of galvanised bolts , nuts, check nuts and washers of galvanised iron steel all as shown in electrical plate no.5 and connected to earth test point as specified and directed including testing on completion complete as specified and directed.
Supply and lay cable fixing to walls with proper saddles XLPE insulated heavy duty galvanised steel strip armoured LT 1100 volt grade with aluminium conductors multistranded of size 50 Sqmm 4 core confirming toIS laid in trenches/pipes/walls including removing of unserviceable cable complete as specified and directed.
All as per item No.43 above but 4 core 16sqmm complete all as specified and directed by Engr-in-charge.
All as per item No.43 above but 4 core 25sqmm complete as specified and directed by Engr-in-charge.
M&L for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground, earth pit not less than 2.25 meter deep below ground level, connected to 20x3 mm size copper strip as earthing strip by means of bolts, nuts, check nuts, and washers of copper or steel all as shown in electric plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including provn of necessary excavation and earthwork in any type of soil, PCC pit, RCC cover and 20 mm bore medium grade watering pipe, water funnel with GI wire mesh, 40 mm bore medium grade protection pipe, common salt, charcoal dust, returning filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion all as specified
M&L for Earth continuity conductor or main earthing lead fixed to wall on epoxy /OMC insulators or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3mm copper strip complete as specified and directed by Engr-in-charge.
M&L for 1 run of PVC FRLS copper conductor cable of size 4 sqmm through pvc conduit for earth connection from LT panel to existing Distribution board by means of Lugs /nut bolts complete as specified and directed by Engr-in-charge.
M&L for 1 run of PVC FRLS copper conductor cable of size 6 sqmm through pvc conduit for earth connection from LT panel to existing Distribution board by means of Lugs /nut bolts complete as specified and directed by Engr-in-charge.
M&L sub main wiring using 2 runs of 2.5 sq mm FR PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC casing and caping along with 1 run of 2.5 sq mm PVC insulated copper conductor FR cable as earth lead connected to common earth dolly complete all as specified and directed by Engr-in-charge. Note :- One run of PVC casing and caping, 3 runs of 2.5 sqmm PVC insulated copper conductor cable will be measured as one unit.
M&L sub main wiring using 4 runs of 6 Sq mm FR PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through suitable size of PVC conduit along with 2 runs of 6 Sq mm PVC insulated copper conductor FR cable as earth lead connected to common earth dolly complete all as specified including taking down the unserviceable wiring complete as specified and as directed. Note : One run of PVC conduit and 6 runs of 6 sqmm PVC insulated copper conductor cable will be measured as one unit..
S&F Modular switch one way 6A ,1 module complete as specified and as directed. Make : Legrand/ Crabtree or Equivalent as approved by GE.
S&F Modular socket 6 A,2/3 pin combined 2 module complete as specified and as directed. Make : Legrand/ Crabtree or Equivalent as approved by GE.
S&F Modular white cover plate with frame 6 module complete as specified and directed. Make : Legrand/ Crabtree or Equivalent as approved by GE.
S&F Modular white cover plate with frame 12 module complete as specified and directed. Make : Legrand/ Crabtree or Equivalent as approved by GE.
S&F Modular metal flush box 3 Module complete as specified and directed
S&F Modular metal flush box 6 Module complete as specified and as directed.
S&F Modular metal flush box 12 Module complete as specified and as directed.
S&F in repair MCB DB TPN double door for 6 way with 200 Amps rated bus bar 415 Volts complete as specified and as directed. Make: Legrand/Indo Asian/ Havells/Standard.
S&F in repair MCB TPN 415 Volts 63 Amps complete as specified and as directed. Make: Legrand/Indo Asian/ Havells/Standard.
S&F in repair MCB single pole 5 to 32 Amps capacity 230 Volts complete as specified and directed.
S&F Single Pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete as specified and directed.
Demolition of stone slab and tiles of any description or thickness in floors, aprons etc. laid bedded and ponted in any mortar complete as specified and directed.
M&L machine cut granite stone slab 20mm thick of approved colour and shade as in floors laid over 20mm thick screed bed in CM (1:6) and jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the slab including grinding and polishing complete as specifed and directed.
M&L machine cut kota stone slab flooring with 20-25mm thick over and including 20mm thick screed bed in CM (1:4) and jointed with grey cement slurry and pointed with white cement mixed with pigment to match the shade of the slab including rubbing polishing complete as specified and directed.
Gates Infra Construction Co
Sreekrupa Enterprises
Palace constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .