GE (Army) Central Jodhpur
GE (Army) Central Multan Line Army Area Jodhpur
REPAIR AND MAINT OF ACS REFRIGERATION AND DEEP FREEZE AND REPAIR AND MAINT OF WINDOW SPLIT AND DUCTABLE TYPE ACS OF GE ARMY CENTRAL JODHPUR (9080/E8)
2022_MES_506234_2
GE/J/A- OF 2021-22 (9080/E8)
Open Tender
Civil Works
Item Rate
180 days
GE (Army) Central Multan Line Army Area Jodhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (Army) Central Jodhpur
₹63,000
23 Mar 2022
22 Feb 2022
14 Mar 2022
22 Feb 2022
12 Mar 2022
28 Feb 2022
Amount
Note:- All items in BOQ are for "Materials and labour / Supply and fix" and to be executed in "Repairs unless otherwise specifically mentioned as "Supply only" or Fixing only" in BOQ Bidders are required to quote their rates accordingly
Repair to Air Conditioner : M&L for checking of window type air conditioner of any make/capacity (1.5/2 TR ) in location and position at any site in Army Area Jodhpur including necessary servicing .ie. electrical connection/wiring, cleaning condenser, blower fan motor servicing including replacement of both end bushes of approved quality cleaning cooling coil, replacement of micro filter of approved quality, testing for proper functioning of window type air conditioner in situ, complete all as specified and as directed by Engr-in-Charge. (The rates quoted are deemed to be included for maintaining complete and proper record of machine ie Make with cap and location , date of servicing, user signature after servicing, concerned JEs signature duly verified by the Engr-in-Charge) Note : (a) Cleaning and descaling of condensing unit and cooling coil with caustic soda mixed water and air blower and sludge etc. all as directed by Engr-in-Charge. (b) Greasing/oiling of blower fan motor.including charging of gas if reqd and cost of gas will be paid seperately under respective item of BOQ.
M&L checking of split type air conditioner indoor unit of any make and capacity (1.5/2 TR ) in location and position at any site in Army Area unit Jodhpur including necessary servicing .ie. electrical connection/wiring, cleaning condenser, blower fan motor servicing including replacement of both end bushes of approved quality cleaning cooling coil, replacement of micro filter of approved quality and testing for proper functioning of split type air conditioner, complete all as specified and as directed by Engr-in-Charge. (The rates quoted are deemed to be included for maintaining complete and proper record of machine ie: make with cap and location , date of servicing , user signature after servicing , concerned JEs signature duly verified by the Engr- in-Charge. Note : (a) Greasing /oiling of blower fan mator including charging gas if reqd and cost of gas will be paid seperately under respective item of BOQ.
M&L for disconnecting, existing u/s sealed unit and replacement with new rotary type sealed reciprocating conventional compressure cap 1.5 ton ( for Window type ACs), including pressuring system checking for leakage in system and flush out the system etc., complete all as specified and as directed Make : Kirloskar/ Tecomusha Note: Gas charging etc shall be measured and paid separately under relevant item of schedule 'A'.
M& L for disconnecting, existing U/S sealed unit and replacement with new rotery type sealed reciprocating conventional compressure cap 2.0 ton AC including pressuring system ,for checking of leakage in system and flush out the system etc., complete all as specified and as directed Make : Kirloskar/ Tecomusha Note: Gas charging etc shall be measured and paid separately under relevant item of schedule 'A'.
M&L for rewinding of blower motor (speed 900 RPM) of window/Split Air conditioner of cap. 1/5 HP any make with super enamelled copper conductor winding wire including replacement of worn out bushes, shaft and capacitor etc., and testing, complete all as specified and as directed. Make : Atlas/ Chetak/ Devidayal
Supply and replacement of running capacitor clip type of cap. 50 MFD, 240 volts 50 cycles for window type air conditioner 1.5 Ton Cap, complete all as specified and as directed. Make : EPCOS/ KELTRON/ SIEMENS/ SHARDA.
Supply and replacement of starting capacitor clip type of cap. 80-100 MFD, 440 volts 50 Hz for window type Air conditioner, complete all as specified and as directed. Make : EPCOS/ KELTRON/ SIEMENS/ SHARDA
All as per item No 8 above but of cap 100/120 MFD for 2 TR Split/window type AC, complete all as specified and as directed. Make : EPCOS/ KELTRON/ SIEMENS/ SHARDA
S&F over load protection with relay No 1622/2085 for 1.5 Ton cap. For split/ window type AC, complete all as specified and as directed. Make : Shri Ram/Renutrol/Annapurna
S&F over load protection with relay No 1062 for split/window type AC, for 2.00 Ton Cap, complete all as specified and as directed. Make : Shri Ram/ Annapurna/ Indofoss No 2059/ Ranutrol
M&L for replacement of cooling coil for window type AC Cap. 1.5/2.0 TR as per existing, complete all as specified and as directed.
M&L for taking out and refixing split type ACs any cap/Make from one location to another location including pressurising the system ,testing and leakage rectification in system , making good disturbed surfaces and testing, complete all as specified and as directed by Engr-in-Charge. Note :- (i) Rates are deemed to included for making holes for suction , discharge pipe and condensed water pipe (ii ) extra lenth of copper pipe duly insulated and gas if required shall be paid seperately .
M&L for replacement of sub main wiring two run of PVC insulated,1100 volts grade ,FRLS, single core4 sq mm (Nominal area) multistranded copper conductor cable including one 4 Sq mm solid copper conductor PVC insulated cable in and including 20 mm dia rigid PVC conduit (ISI Marked) complete including accessories , junction boxes with sheet top cover and other accessories, complete all as specified and as directed by Engr-in-Charge. NOTE : Two run of 4 Sq mm and one run of4 Sq mm as earth wire and pipe shall be measured as one length. (Make : Polycab/ Finolex/ Havells
M&L for replacement of cord less remote with control panel suitable for split type AC Cap 1.5/2.0 Ton, complete all as specified and as directed. Note : Make of remote shall be all as per existing.
M&L for replacement of Swing motor of split type AC cap 1.5/2.0 Ton with flapper, complete all as specified and as directed by Engr-in-Charge. Make Bluestar/Toshiba/LG/Voltas
M&L for replacement of PVC condensed water drain pipe 15 mm dia for split type AC complete including providing saddle with clamping arrangement, complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of copper discharge tube of size 3/8" duly nylon insulated, complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of copper suction tube of size 5/8" duly nylon insulated all as specified by Engr-in-Charge.
S&F blower motor of indoor unit for 1.5 TON cap split type AC (as per sample) as in replacement, complete all as specified and as directed. Make Blue star/Voltas/Toshiba
S&F blower motor of indoor unit for 2 TON cap split type AC (as per sample) as in replacement, complete all as specified and as directed. (Make Blue star/Voltas/Toshiba
Supply and fixing of indoor unit for 1.5 TON cap split type AC (as per sample) as in replacement, complete all as specified and as directed. (Make Blue star/Voltas/Toshiba
Supply and replacing auxillary supply PCB for indoor unit of split type ACs 1.5 TON capacity of any make and model (as per sample), complete all as specified and as directed.(Make Blue star/Voltas/Toshiba
Supply and replacing secondary PCB for indoor unit of split type ACs 2 Ton of any make and model (as per sample), complete all as specified and as directed.(Make Blue star/Voltas/Toshiba
M&L checking of split type three phase air conditioner of any make / capacity 7.5/5.5/3.0 in location and position at any site in AA Jodhpur including necessary servicing ie: electrical connection /wiring, cleaning condenser, blower fan motor servicing including replacement of both end bushes of approved quality cleaning cooling coil ,replacement of micro filter of approved quality and testing for proper functioning of split type air conditioner, complete all as specified and as directed by Engr-in-Charge. (The rates quoted are deemed to be included for maintaining complete and proper record of machine ie: make with Cap and Location., date of servicing , user signature after servicing , concerned JEs signature all as directed by engineer incharge ) Note : The work is to be carried out in war centre existing location and position
M&L for ,pressurising complete system of split type three phase air conditioner, checking leakage and flushing out system, rectification of leakages if any and including gas charging using refrigerant M- 404/444/R-22 oil charging complete in compressor /Split type AC cap.7.5/5.5/3 Ton, complete all as specified and as directed & with entire satisfaction of Engr-in-Charge Note : (i) The work is to be carried out in war centre existing location and position. (ii) Cost of Gas will be paid under separately under BOQ.
M&L for disconnecting, existing U/S sealed unit and replacement with new three phase hermatic sealed rotary compressure cap -3.5/3.76 ton (for split type ACs) , Make : HITACHI Note : Gas charging etc shall be measured and paid separately under relevant item of schedule 'A'.
Supply only refrigerant gas M- 404/444/R22, complete all as specified and as directed. Make : Maffron/ Floron Note : (i) The gas is to be supplied in cylinder duly sealed by manufacturer/ factory sealed with proper PVs and other documents .
Supply and replacing blower motor of indoor unit for 7.5 TON cap split type AC (as per sample) as in replacement, complete all as specified and as directed. Make : Blue star/ Voltas/ HITACHI
Supply and replacing blower motor of indoor unit for 5.00/3.5 TON cap split type AC (as per sample) as in replacement, complete all as specified and as directed. Make Blue star/Voltas/HITACHI
Supply and replace PCB for indoor unit of three phase split type ACs any capacity, complete all as specified and as directed. Make : HITACHI
Supply and replace PCB for Out door unit of three phase split type ACs any capacity, complete all as specified and as directed. Make : HITACHI
Supply and replacing contactor for outdoor unit of Three phase split type Acs any capacity (Make as per existing /sample), complete all as specified and as directed.
Supply and replacing fan motor of outdoor unit for 4/5 Ton cap Three phase split type AC ( as per sample) as in replacement, complete all as specified and as directed. Make : Blue star/ Voltas/ HITACHI
Supply and replacing fan motor/Blower motor for out door/indoor for 3/3.5 TON cap three phase split type AC (as per sample) as in replacement, complete all as specified and as directed. Make : Blue star/ Voltas/ HITACHI
M&L for carefully dismentlling of automatic electronic voltage stablizer of cap 4KVA/5 KVA of any make and replacement of PCB and transformer complete unit reassembling and testing, complete all as specified and as directed.
M&L for replacement of thermostatic switch for window type AC cap. 1.5/2.00 Ton Capacity, complete all as specified and as directed. Make : Anupurna/ Indofost No 2059/ Ranutrol
Supply and replacing single pole and neutral enclosure with 2 pin earth plug ad socket complete with one MCB SP 25 Amps as in replacement, complete all as specified and as directed. Make : Legrand/ Havells
M&L for replacement of PVC/Fibre sheet 3m thick of superior quality of canopy of out door unit, complete all as specified and as directed by Engineer-in-Charge.
M&L for permanent type stiker of size 150x300 mm having following details in letters not exceeding 25 mm, complete all as specified and as directed. (i) Machine Srl No. ______________ (ii) MES No ______________ (iii) Date set to work ______________ (iv) PRB Page No _______________ (v) location _______________
Repair to Refrigerators/ Deep freezer : M&L,checking of Refrigerators/Deepfreezer of any make / capacity in location and position at any site in Army Area Jodhpur including necessary servicing ie: electrical connection /wiring, cleaning , door gasket cleaning evaporator cleaning and testing for proper functioning of refrigerators/ deep freezer, complete all as specified and as directed by Engr-in-Charge. (The rates are deemed to be included for maintaining complete and proper record of machine ie: make with srl no ,SM no. capacity, date of servicing, user signature after servicing , concerned JEs signature all as directed by Engineer-in-Charge)
M&L for replacement of unserviceable hermetically sealed compressor of Deep freezer 405 Ltr Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete all as specified and as directed. NOTE : (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturer company. (ii) The new unit will be purchased from authorised dealer only as per existing make and model.
M&L for replacement of unserviceable hermetically sealed compressor of Refrigerator / deep freezer 310/280 Ltr Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete all as specified and as directed. NOTE : (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturer company. (ii) The new unit will be purchased from authorised dealer only as per existing make and model.
All as per item No 43 above but for 165/170/180 /220 Ltr capacity refrigerator, complete all as specified and as directed. Make : Tecansha/ LG
M&L for replacement of relay suitable for 286/310/320 Litres cap. Refrigerator, complete all as specified and as directed. Make : Renutrol/ Shriram/ Annapurna/ KLIXON
All as per item No. 45 but cap 165/220 Ltrs Refrigerator, complete all as specified and as directed.
M&L of replacement of thermostat automatic defrost with knob suitable for 165 to 310 liters cap refrigerator, complete all as specified and as directed. Make : Annapurana/ Indofos
M&L for replacement of door gasket of best quality complete suitable for 286/310 litres cap. Refrigerator as per manufacturer's instruction, complete all as specified and as directed by Engr-in-Charge.
All as per item No. 48 above but for 165/220 Ltrs Cap, complete all as specified and as directed.
M&L bulb for pin/screw type, 230 Volts suitable up to310 Ltrs Cap. Refrigerator as in replacement
M&L for replacement of freezer door incl. necessary door springs, screws etc for 286/310 Ltrs Cap. Refrigerator, complete all as specified and as directed by Engr-in-Charge.
All as per item No. 51 above but for 165/220 Ltrs cap. Refrigerator, complete all as specified and as directed.
M&L for replacement of door lock with keys-2 nos. for any capacity of refrigerator (as per sample) approved by Engr-in-Charge.
M&L for replacement of PVC chiller tray and suitable for 286/310 Ltrs Cap. Refrigeraator complete of matching size, complete all as specified and as directed.
M&L for replacement of PVC chiller tray suitable for 165/170/180 ltrs capacity refrigerator complete of matching colour, complete all as specified and as directed.
M&L for patch work (in the outer body of water cooler/refrigerator/Deep freezer with 20 gauge PGI sheet upto required length/width &hight incl necessary welding/brazing etc., complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of refrigerator door handle of 165 to 320 Ltrs Cap. Of any make and model, complete all as specified and as directed.
M&L for repairing to bottom/ foundation of refrigerator any cap. With 20 gauge PGI sheet, angle iron frame made out of 25 X 25 X3 mm angle and incl necessary welding work, complete all as specified and as directed by Engr-in-Charge
M&L for replacement of evaporator ( Freezer ) assy with door and fixing brackets complete with screw, jointing of tubes etc and testing of cap220 to 320 Ltrs refrigerator (any make), complete all as specified and as directed.
All as per item No 59 above but of capacity 165/180 Ltr refrigerator, complete all as specified and as directed.
M&L for replacement of condenser unit of refrigerator cap.280/ 286/310/320 Ltrs of any make incl jointing of tubes and testing etc., complete all as specified and as directed. (gas charging will be measure and paid under relevant item separately).
All as per item No 61 above but for 165/180/220 ltrs capacity refrigerator, complete all as specified and as directed.
M&L for leakage detection including flushing out system,pressurising,including gas charging(as per existing) suitable for 286/310 ltrs, complete all as specified and as directed.
M&L for leakage detection including flushing out system,pressurising,including gas charging (as per existing ) suitable upto 220 ltrs, complete all as specified and as directed.
M&L for sub main /Circuit wiring with 1.5 sq mm copper conductor cable 1100 volts grade conforming to relevant IS and ISI Marke including same size of earth wire and taking out old unserviceable sub main wiring including Making good to distrubed surface, complete all as specified and as directed.
Supply and replacement of condensor fan motor complete for deep freezer cap. 310 to 405 Ltrs. In existing location and position (as per sample), complete all as specified and as directed.
M&L for replacement of timer frost free refrigerator (as per sample), complete all as specified and as directed.
M&L for replacement of fan motor double door frost free refrigerator (as per sample), complete all as specified and as directed.
Supply and replacement of PCB as per existing suitable for 220 to 320 Ltrs refrigerator/Deep Freezer, complete all as specified and as directed.
M&L for carefully dismentling of automatic voltage stablilzer electronic type of cap up to 3 KVA of any make including replacement of PCB and transformer complete kit reassembling and testing etc., complete all as specified and as directed.
Supply and replacement of 3 Pin Plug Top 16 Amps (ISI Marked) 230 Volts, complete all as specified and as directed. Make : ANCHOR/ PLAZA/ Legrand
Supply and replacement of 3 Pin Plug Top 06Amps (ISI Marked) 230 Volts, complete all as specified and as directed. Make : ANCHOR/ PLAZA/ Legrand
M&L for replacement of PVC Connection pipe (ISI Marked) 300m long heavy duty, complete all as specified and as directed.
M&L for replacement of PVC stop cock (ISI Marked) heavy duty, complete all as specified and as directed.
Repair to Desert cooler M&L for (in existing location and position) taking out and refixing after repairs, including rewinding of Desert Cooler fan motor of any make, 3 speed,1400 RPM of capacity 1/5 HP with super enameled copper winding wire of appropriate size (as per existing), complete all as specified and as directed. Make : DEVIDAYAL / CHETAK
Supply and replacement of bush for cooler fan motor as per existing sample, complete all as specified and as directed.
Supply and replacement of shaft for cooler fan motor as per existing sample, complete all as specified and as directed.
Supply and replacement of oil filled capacitor 4.00 MFD for desert cooler fan motor , complete all as specified and as directed.
M&L for replacement of bottom tank and top (in existing location and position) of approx size - 750 X 750 X 200 mm (as per existing) for Desert Cooler made out of 18 gauge PGI sheet with and including two coats of synthetic enamel painting over one coat of red oxide primer on the new surfaces to match with existing surface outside and inside surface with approved quality paint including leakage testing, complete all as specified and as directed by Engineer-in-charge.
M&L for (in existing location and position) replacement of front grill (as per existing)( horizontal and vertical members moveable) of the Desert Cooler made out of 20 gauge PGI sheet with Name plate complete all as approved by Engineer-in-charge.
M&L for replacement of side supporting columns to be fabricated out of 20 gauge PGI sheet of size 80x80x800 mm with and including necessary nut, bolts etc., complete all as specified and as directed by Engineer-in-charge.
M&L for replacement of side/rear panel made out of 22 gauge PGI Sheet with suitable handles with and including two coats of synthetic enamel paint over one coat of red oxide primer to match with the existing desert cooler, complete all as specified and as directed by Engineer-in-charge.
M&L for painting to old steel surfaces of Desert cooler capacity up to 5000 Cft with one coat of synthetic enamel spray paint hammer tone paint of approved colour over one coat of red oxide primer on external surface and one coat of anti corrosive black paint inside the Body tank and side grills over a coat of red oxide primer complete including scraping/rubbing with wire brush on old surface of Desert cooler and writing of MES No etc complete at site or at E/M store yard, complete all as specified and as directed. by Engr-in-Charge .
M&L for replacement of Desert Cooler fan motor capacity 0.5 HP three speed, 1400 RPM single phase with aluminium fan blade, bracket supporting stand, complete all as specified and as directed by Engr-in-Charge . Make : Crompton/ GEC/ COOL HOME.
M&L for replacement of submersible pump of discharge head 2.5 Mtr 220-240 Volts AC Supply single phase 40 watt, complete all as specified and as directed by Engr-in-Charge Make : RADO KR-1900/ Khaitan/ Coolhome/Symphony
M&L for replacement of Wood wool pad for Desert Cooler of size 500 x 550 x30 mm (set of three pads) superior quality including binding properly with GI wire of 16 SWG with gril, complete all as specified and as directed by Engr-in-Charge .
M&L for replacement of MS weld wire mesh having apparture size 25 mm and fitted in side grills/rear, complete all as specified and as directed by Engr-in-Charge.
Material and labour for replacement of Wood wool pad Heavy duty for Desert Cooler of suitable size (set of three pads) superior quality including binding properly with GI wire of 16 SWG with grill, complete all as specified and as directed by Engr-in-Charge .
M&L for replacement of PVC insulated and PVC sheathed cable copper conductor 3 core 1.0 Sqmm cross sectional area superior quality, complete all as specified and as directed by Engr-in-Charge. Make: Plaza/ Finolex
M&L for replacement of PVC water distribution cup of one inlet and 3 outlets fixed with MS nuts and bolts complete (as per sample), complete all as specified and as directed Engr-in-Charge .
M&L for replacement of PVC elbow suitable for desert cooler (as per sample), complete all as specified and as directed by Engr-in-Charge .
M&L for replacement of PVC pipe 15 mm dia heavy duty for Desert Cooler Pump, complete all as specified and as directed by Engr-in-Charge .
M&L for painting to desert cooler stand with two coats of synthetic enameled paint of approved colour over a coat of red oxide primer including preparation of old surfaces, complete all as specified and as directed by Engineer-in Charge.
M&L for replacement of motor fixing ring (not less than 25 mm width ) for desert cooler eight screw / clip type(asper sample), complete all as specified and as directed by Engr-in-Charge .
Supply and replacement of 4mm thick ply ISI marked duly making hole for fixing single cooler in window of approximate size 1.5X1.2 mtrs for cooler grill approximate 24"X24" to be replaced in existing location and position in army area, complete all as specified and as directed by Engr-in-Charge .
M&L for taking down desert cooler installed at ground floor safely , including cleaning inside , outside , motor oilng sevicing and pump servicing including putting up in same location and position, complete all as specified and as directed. NOTE : Any replacement of spare shall be measured and paid separately under respective item of BOQ
M&L for taking down desert cooler installed at first floor safely , including cleaning inside , outside , motor oilng sevicing and pump servicing including putting up in same location and position, complete all as specified and as directed. NOTE : Any replacement of spare shall be measured and paid separately under respective item of BOQ.
M&L for taking down desert cooler installed at second floor safely , including cleaning inside, outside , motor oilng sevicing and pump servicing including putting up in same location and position, complete all as specified and as directed. NOTE : Any replacement of spare shall be measured and paid separately under respective item of BOQ.
M&L for stand flush to wall for desert cooler fabricated out of MS angle iron 40 x 40 x 6 mm , 1.2 meter long bend to shape as top size 600 x 600 mm duly welded with two members to tie vertical support , including painting two coats of synthetic enamelled paint over a coat of red oxide primer including M&L for steel rack bolt / fastner 100 mm long 12 mm dia - 4 Nos for fixing stand, complete all as specified and as directed by Engr-in-Charge .
S&F in existing location and position PTMT stop cock 15 mm dia high pressure screwed for iron pipe, complete all as specified and as directed. Make : PRAYAG /POLYTUFF
S&F in existing location and position PTMT Ball valves 15 mm dia high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe, complete all as specified and as directed. Make: PRAYAG/POLYTUFF
Supply and replace PVC moulded box of switch socket combination of cap - 15 Amp, complete all as specified and as directed. Make : ANCHOR/ LEGRAND
Repair to Water Cooler M&L for disconnecting, loading, unloading and transportation of Water coolers from existing location and position in A/A site for repairing of Water coolers of any make/capacity including reinstallation and testing at site after repairs, complete all as specified and as directed by Engr-in-Charge NOTE : (i) Material required for defective / U/S parts shall be paid separately under relevent items.
M&L for checking of Water cooler of any make / capacity in location and position at any site in Army Area Jodhpur including necessary servicing i.e. making good electrical including copper terminal, cleaning , drain water system including replacement of hose clamp etc . complete , cleaning condensor , condenser fan motor , door gasket , cleaning storage water tank cleaning and testing for proper functioning ofwater cooler, complete all as specified and as directed by Engr-in-Charge.(The rates are deemed to be included for maintaining complete and proper record of machine ie: make with srl no ,SM no. capacity, date of servicing , user signature after servicing , all as directed by Engineer in-charge )
M&L for replacement of unserviceable hermetically sealed compressor of water cooler 150 Ltr storage having cooling capacity 100 Ltrs / hour Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete all as specified and as directed. Makes : Tecumsha/ Kirloskar copeland NOTE : (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturing company (ii) The new unit will be purchased from authorised dealer only as per existing make and model.
All as per item No. 106 above but for 60/120 Ltr storage capacity with cooling capacity 60 Ltrs / hour water cooler, complete all as specified and as directed. Make : TECUMSHA/ KIROSKAR COPELAND.
All as per ser item No 3 above but for 40/80 Ltr storage capacity with cooling capacity 40 Ltrs / hour water cooler, complete all as specified and as directed. Make : TECUMSHA/ KIROSKAR COPELAND.
M&L for replacement of copper filter and capillary tube of water cooler cooling capacity 40 Ltr/hrs, complete all as specified and as directed.
M&L for replacement of of cooper filter and capillary tube of water cooler cooling capacity 60 Ltrs per hour, complete all as specified and as directed.
M&L for replacement of cooper filter and capillary tube of water cooler cooling capacity 100 Ltr per hour, complete all as specified and as directed.
M&L for replacement of relay with over load protection for 40/80 Ltr/hrs cooling capacity suitable as per site requirement, complete all as specified and as directed. Make : Ranutrol/ Rockwell/ Annapurna
M&L for replacement of relay with over load protection for 60Ltr/hrs cooling capacity suitable as per site reuqirement, complete all as specified and as directed. Make : Ranutrol/ Rockwell/ Annapurna
M&L for replacement of relay with over load protections for 100 Ltr/hrs cooling capacity suitable as per site requirement, complete all as specified and as directed. Make : Ranutrol/ Rockwell/ Annapurna
M&L for replacement of condensor fan motor HP-1/32, RPM-1300 suitable for water cooler having cooling cap 40 Ltr/hr with clips and motor fixing stand with fan blade (ISI marked), complete all as specified and as directed. Make : AUE or Equivalent
M&L for replacement of condensor fan motor HP-1/16, RPM-1300 suitable for water cooler having cooling cap 60 to100 Ltr/hr with clips and motor fixing stand with fan blade (ISI marked) Make : AUE or Equivalent
M&L for Repalcement of thermostat switch with knob for water cooler, having cooling capacity 40/60/150 Ltrs/hr, complete all as specified and as directed. Make : Rasnutrol no 1051 or Indfoss No 2064/Annapurna
M&L for patch repair work of worn out MS body of water cooler any capacity made out of 22 gauge mild steel sheet including welding and making good with paint to match with existing, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of drain PVC pipe, 25 mm bore for cooling cap 40 Ltr /Hrs 90 cms in length with two Nos mild steel clamps and necessary brass screws etc., complete all as specified and as directed. Make : RAJDOOT/ KOHINOOR
All as per item No. 119 above but size 32 mm bore suitable for cooling Cap 60 to 100 Ltrs/Hrs water cooler and not more than 1.00 meter, complete all as specified and as directed.
M&L for replacement of SS drain water tray made out of 24 gauge stainless Steel sheet of size of 30x12x5 cm deep with necessary GI screws and PVC drain water connection arrangement of size not less than 25 mm dia (as per sample), complete all as specified and as directed.
M&L for replacement of water storage tank top lid complete made out of 22 gauge mild steel sheet of existing shape and size for water cooler storage cap 120 to 150 Ltrs , of appropriate thickness on one side with door gaskit including , aluminium hinges 50 mm long 2/3 nos. and making good and painting with approved colour to match the existing colour, complete all as specified and as directed.
M&L for replacement of water storage tank top lid complete made out of 22 gauge mild steel sheet of existing shape and size for water cooler cap 80Ltrs., platic sheet of appropriate thickness on one side with door gaskit including , aluminium hinges 50 mm long 2/3 nos. and making good and painting with approved colour to match the existing colour, complete all as specified and as directed.
M&L for replacement of rubber magnet gasket fixed with top cover of water cooler of 80/120 litres storage capacity, complete all as specified and as directed.
M&L for replacement of rubber magnet gasket fixed with top cover of water cooler of 150 litres storage capacity, complete all as specified and as directed.
M&L for replacement of worn out bottom base of water cooler foundation frame made out of 1.6mm thick MS sheet for water cooler, & frame work made out of angle iron25x25x3 mm, including cutting welding brazing soldering , making holes for sealed unit , condenser with condensor fan motor , including painting black colour ( two coats ) synthetic enamelled paint over a coat of red oxide primer etc., and finishing, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of water cooler body back sheet with 22 gauge mild steel sheet including suitable size( as per existing) and necessary painting, screws etc. all as specified and directed by Engineer-in-Chage
M&L for replacement of water cooler front pannel with 20 gauge mild steel sheet including suitable size( as per existing) and necessary screws/nuts/bolts/washers etc. for 40 ltrs/hour capacity, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of condensor fan motor mounting stand made out of mild steel sheet 3 mm thick size 400x150 mm and refixing on the existing base, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of foundation stand of water cooler fabricated out of angle iron 25x25x3 mm 1600 mm in length incl. Welding and necessary fitting with patch work to bottom portion of 20 gauge MS sheet size 40x15 cm, complete all as specified and as directed.
S&F CP lift cock, 15mm bore made of brass self closing vertical type made of brass nickle chromium plated with CP adaptor and nipple, complete all as specified and as directed. Make : Mayor/ C-Sons/ G-Sons
S&FCP push cock, 15mm bore made of brass self closing horizontal type made of brass nickle chromium plated with CP adaptor and nipple, complete all as specified and as directed. Make : Mayor/ C-Sons/ G-Sons
M&L for painting to water cooler of storage cap. 150/120/80 Ltrs spray painting with two coats of synthetic enamelled paint (first quality) including preparation of surface, complete all as specified and as directed. Make : ASIAN/ BERGER/ NEROLAC .
M&L for repair to storage water tank of cooler of cooling cap 40 Ltr/hour by soldering / brazing to prevent leakage spots incl. cleaning of water tank and testing complete (NOTE : work is to be carried out in existing position as and where machine in army area)
M&L for repair to water tank cooler of cooling cap 60 Ltr/hour cap. by soldering, brazing to prevent leakage spots incl. cleaning of water tank and testing, complete all as specified and as directed. NOTE : work is to be carried out in existing positio as and where machine lyes in army area
M&L for repair to water tank of water cooler of cap. 150 ltrs/hrs, by soldering / brazing to prervent leakage spots incl. cleaning of water tank and testing, complete all as specified and as directed. NOTE : Repairing to be done by the contractor at various location of units
M&L for replacement of starting capacitor 40-60 Mfd oil filled 240 volt AC Supply, complete all as specified and as directed. Make : Asian/ Atlas/ Epcos/ SPAN/ Sharda Texla
M&L for replacement of starting capacitor 60-80 Mfd oil filled 240 volt AC Supply, complete all as specified and as directed. Make : Asian/ Atlas/ Epcos/ SPAN/ Sharda Texla
M&L for replacement of running capacitor of 15 Mfd oil filled, complete all as specified and as directed. Make : Asian/ Atlas/ Epcos/ SPAN/ Sharda
M&L for replacement of running capacitor of 10 Mfd oil filled, complete all as specified and as directed. Make : Asian/ Atlas/ Epcos/ SPAN/ Sharda
M&L for replacement of running capacitor of 2.5 Mfd oil filled, complete all as specified and as directed. Make : Asian/ Atlas/ Epcos/ SPAN
M&L for PVC float valve 15 mm bore with PVC float, ball (ISI Marked) complete with check nut/socket/GI nipple, complete all as specified and as directed by Engineer-in-Charge Make: PRAYAG/ POLYTUFF
M&L for replacement of water cooler side panel with 20 gauge MS sheet as per sample incl. necessary screws/nuts/bolts/washers etc for 40/60/150 Ltrs/hour cap, complete all as specified and as directed by Engineer-in-Charge
M&L for pressurising of system & detecting of leakages in system , flushing , replacement of copper filter and gas (using maffron M- 134 gas ), oil complete incl testing and commissioning of water cooler having cooling Capacity 40 Ltrs per hour of any make, complete all as specified and as directed.
M&L for pressurising of system & detecting of leakages in system , flushing , replacement of copper filter and Gas (using maffron gas - M-134 ) charging , oil complete incl testing and commissioning of water cooler having cooling Capacity 60 Ltrs per hour of any make, complete all as specified and as directed.
M&L for pressurising of system & detecting of leakages in system , flushing , replacement of copper filter and gas charging of Gas (using maffron gas M-134 ), oil complete incl testing and commissioning of water cooler having cooling Capacity 100 Ltrs per hour of any make, complete all as specified and as directed.
M&L for replacement of aluminium fan blade for condenser fan motor (as per sample) suitable for water cooler having cooling capacity 40 Ltr/hr water cooler, complete all as specified and as directed.
M&L for replacement of aluminium fan blade for condenser fan motor (as per sample) suitable for water cooler having cooling capacity 60/150 Ltr/hrs water cooler, complete all as specified and as directed.
M&L for replacement of condenser unit complete suitable for 40 Ltr/hrs cap. Water cooler including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed, complete all as specified and as per direction of Engineer-in-Charge
M&L for replacement of condenser unit complete suitable for 60 to 100 Ltr/hrs cap. Water cooler including gas chargin flushing out the system brazing, welding and jointing the suction reed and discharge reed, complete all as specified and as per direction of Engineer-in-Charge
M&L for replacement of condenser unit complete suitable for 150 Ltr/hrs cap. Water cooler including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed, complete all as specified and as per direction of Engineer-in-Charge
M&L for replacement of PVC insulated and PVC sheathed flexible cable , multistranded copper conductor 3 core 48/0.20 cross sectional area superior quality, complete all as specified and as directed. Make : Plaza/ Finolex/ Polycab
Note:- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
Surendra Singh
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .