Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance COURT ROAD ANAND HOME C 302 KASHIPUR US NAGAR UTTARAKHAND | UDAM SINGH NAGAR | UTTARAKHAND | 244712 | Admitted-Finance |
| 2 | Admitted-Finance CC 1 BOOTH NO 8 JANTA BHAWAN ROAD SIRSA SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | Admitted-Finance |
| 3 | Admitted-Finance WARD NO 3 OLD BANGALI COLONY KICHHA U S NAGAR | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
23 Jun 2023, 2:00 pmClosed
Executive Engineer
Electricity Distribution Division-2 Rudrapur
REPLALCLEMENT OF CONDUCTOR FROM ACSR WEASEL TO ACSR DOG IN 11KV.FEEDER KASHIPUR FEEDER UNDER 33/11KV SUB STATION DANPUR UNDER THE HEAD SI( U.S. NAGAR )
2023_UPCL3_59523_1
EDD-2(R) (USN) 14/2023-24
Open Tender
Repair and Maintenance Works
Item Rate
365 days
Electricity Distribution Division-2 Rudrapur
Please Refer Tender Document
3 documents required · 3 mandatory
₹1,180
EEEDD
₹45,000
Yes
6 Oct 2023
9 Jun 2023
24 Jun 2023
9 Jun 2023
23 Jun 2023
9 Jun 2023
Amount
Annexure -A ( Works )
Cartage of the ST Pole SP-33/55,( Bottom Portion ot dip Galvanized ) by private truck from Store Centre Rudrapur to work site dump store, including loading and unloading.
Cartage of the Other small materail by private truck from Store Centre Rudrapur to work site dump store, including loading and unloading.
Cartage of 11KV. VCB feeder 350/500 MVA, 400/200/5A, 110 VA by private truck from Store Centre Rudrapur to work site dump store, including loading and unloading.
Errection of Single Pole Structure of ST Pole SP-33 /55 support after digging of pit size 0.60x0.6x1/6 length of support on 300x300x75mm. Stone pad including fixing of 11KV. Pin insulator & Grouting of pole in CC Ratio 1:4:8 in size ( Height 0.45& 0.45 round ) Above ground level including fixing of all accessories as per direction of Engineer In Charge.
Errection of Double Pole Structure of ST Pole SP-33/55support after digging of pit size 0.60x0.6x1/6 length of support on 300x300x75mm. Stoune pad including fixing of 11KV. Pin insulator & Grouting of pole in CC Ratio 1:4:8 in size ( Height 0.45& 0.45 round ) Above ground level including fixing of all accessories as per direction of Engineer In Charge.
Dismantling of Old ACSR Weasel conductor from existing 11KV. Line is section wise including Re-Rolling of conductor shifting of material at one collection for cass cartage including unloading & maeking and back cartage scrap. From site work to JE Store.
Laying and stringing of 11KV. Line 11.250Km. On ACSR Dog conductor and including fixing lf all accessories and providing proper straightning, sagging and binding on insulator & jumpering etgc complete work as per direction of Engineer- In-Charge.
Febrication of M.S. Channel/Angle.
Fixing of M.S. Earth Rod 20x2500mm. For Earthing of support as per RESPO drawing No. RES-12 including earth rod 2.5mm. Deep below ground level connected to support with Earth wire fixing of bolts and nuts.
Fixing of Stay Set complete as per RESPO drawing No. RES-16 with stay rod 16x1600mm. Stay wire 7/8SWG stay set, wire clamps, Nut & bolts abnd fixing of stay clamps of suitable including excavation of earth and grouting of stay in pit with CC 1:4:8 in bottom of pit size 0.60x0.60x0.60 Mtr. including cost of cement, sand stone ballast etc andback filling complete inall respect with all other item T&P etc. as per direction of Engineer In Charge.
Restreightening of tilted pole as per direction of Engineer -In-Charge.
Lopping and Chopping of Tree Branches near by line.
Fixing and fixing of Termination Kit 3x185sq.mm. ( O/D) as per direction of Engineer -In-Charge.
Digging of Mix Soil for Trench Laying of Cable in trance. as per direction of Engineer -In-Charge.
Laying of XLPE cable 3x185sq.mm. as per direction of Engineer -In-Charge.
Laying of Control Cable 6x2.5 sq.mm. as per direction of Engineer -In-Charge.
Earthing work of 11KV. VCB, and Bus coupler & indiir equipment in control room inlcluding providing of required material like G.I. Strip complete work in all respect. as per direction of Engineer -In-Charge.
Replacement of damage 11KV. X-arm.
Annexure - B ( Supply )
Supply of M.S. Stay clamp for ST Pole,SP-33& P.C.C. Pole made of M.S. Flat for size 50x6sq,mm. duly red oxide painted with suitable size with fitted Nuts and bolts and washer as per specification of UPCL.
Supply of M.S. X-arm holding clamp for ST Pole,SP-33 & P.C.C. Pole made of M.S. Flat for size 50x6sq,mm. duly red oxide painted with suitable size with fitted Nuts and bolts and washer as per specification of UPCL.
Supply of M.S. L.T. clamp for ST Pole,SP-33 & P.C.C. Pole made of M.S. Flat for size 50x6sq,mm. duly red oxide painted with suitable size with fitted Nuts and bolts and washer as per specification of UPCL. For 11KV. Top wire.
Supply of M.S. Earth clamp for ST Pole,SP-33 /45/55 & P.C.C. Pole made of M.S. Flat for size 50x6sq,mm. duly red oxide painted with suitable size with fitted Nuts and bolts and washer as per specification of UPCL.
Supply of M.S bracket clamps for ST Pole,SP-55 & P.C.C. Pole made of M.S. Flat for size 50x6sq,mm. duly red oxide painted with suitable size with fitted Nuts and bolts and washer as per specification of UPCL.
Supply of M.S. bracing clamps for ST Pole,SP-33 made of M.S. Flat for size 50x6sq,mm. duly red oxide painted with suitable size with fitted Nuts and bolts and washer as per specification of UPCL.
Supply of P.G.Clamps Dog to Dog conductor per UPCL specifciation New Double Pole 10x12PG=120+Extra 300PG.
Supply of G.I. Electrode 80mm. 3 Mtr. long with backfill compound 50 Kg.
ASHISH ENGINEERING
NUTECH POWER CONTROL
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .