Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 LAccepted-AOC V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.0 L+₹4.3 L (19.7%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L2 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | L3₹27.9 L+₹6.1 L (28.2%)Rejected-Finance | L3 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
24 Jan 2022, 6:00 pmClosed
GE (AF) CHILODA
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
REPAIR AND MAINT OF ELECTRIC SUPPLY, STREET LIGHT, SECURITY LIGHT, DOME LIGHT AND ALLIED WORKS AT SEC-09 GANDHINAGAR AND COMN FLT AHMEDABAD UNDER GE (AF) CHILODA
2021_MES_498158_1
8988/21-22/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Gandhinagar
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹64,000
Yes
21 Mar 2022
29 Dec 2021
26 Jan 2022
29 Dec 2021
24 Jan 2022
12 Jan 2022
Amount
Repair and maintenance of transformer of different capacity as under:- Transformer 500/ 160 KVA carrying out insulation resistant test (HT-LT,HT-E & LT-E), BDV of Oil (top & bottom sample), filtration test, quaterly resistance check of earth pits, arresting of leakage by proper tightening of terminals & joints, replacement of loose or burnt out gasket & proper sealing of valves etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting and removing outdoor transformer after disconnecting HT/ LT cable terminals connections and lowering down from plinth/ platform structure of capacity 160 KVA - 500 KVA and refitting after servicing complete all as specified and as directed by Engineer-in-Charge.
M&L for transportation of transformer to nearest workshop for repair/ replacement of transformer winding and return back for installation in its original position/ location after repairing from workshop upto 500 KVA capacity (Rate is inclusive serviceable transformer rent, only transportation, T&P and manpower) complete all as specified and as directed by Engineer-in-Charge. Note:- Contractor will provide serviceable transformer in place of unserviceable transformer of same capacity till unserviceable transformer return form work shop.
M&L for cleaning bus bar with CRC solution - 2.26, 200ml spray bottle with the help of cotton waste etc complete all as specified and as directed by Engineer-in-Charge.
M&L for rewinding of HT /LT coils with super enameled copper wire/ strips DPC/ super enameled matching with existing gauge and insulating material of high class as per manufacture recommendation with packing/ insulation material in each layer of winding, baking the core assembly with the help of oven duly varnshing the coils to improve IR valve and to eliminate moisture and Inserting the core assembly after repair the core and making connection with HT/ LT bushing studs and closing the tank top cover by fixing nuts, bolts and washers (top cover gasket will be measured and paid for seperately) complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement silica gel breather assembly having iron cap at top & bottom and tighten with suitable size of nuts & bolts filled with silica gel for size of transformer 160 KVA to 500 KVA complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of defective tap changer with tapping arrangement 5% and 7.5% on normal tapping complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of old painted surface of steel surface by brushing/ cleaning strain grease/ oily spots with thinner and two coats of spray painting with spray machine to transformer indoor/ outdoor fixed on pole or in Sub STN at different location capacity upto 500 KVA including writing SM No, MES No and capacity of transformer complete all as specified and as directed by Engineer-in-Charge.
Supply & filling transformer oil low viscosity type conforming to IS-335 (Latest revision) for topping up of transformer (having dielectric strength 60 KV with 2.5mm gap) complete all as specified and as directed by Engineer-in-Charge.
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil extra exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 Sqmm, 3 Core. The fault located equipment will be brought at site within 02 hours of Instruction received, failing of instruction panalty per hour of Rs 2000 will be charged complete all as specified and as directed by Engineer-in-Charge.
M&L for defect rectification in LT cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil extra exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 185 Sqmm, 3.5 Core. The fault located equipment will be brought at site within 02 hours of Instruction received, failing of instruction panalty per hour of Rs 1500 will be charged complete all as specified and as directed by Engineer-in-Charge.
Dehydration/ filtration of transformer oil of transformers, of various capacities installed in Sector-09, Gandhinagar & Comn Flt Ahmedabad under GE (AF) chiloda, by recirculation existing transformer oil with trolley mounted filtration plant till dielectric strength is up to 40 KV to 50 KV complete all as specified and as directed by Engineer-in-Charge. Note:- Quoted rates shall be deem to include for following:- (i) Oil shall be tested after filtration and test result will be recorded before & after filtration of oil. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete.
S&F in replacement worn out HT terminal with bush of existing size for transfomers upto 500 KVA capacity to arrest leakage by opening top cover and refixing the same with replacement of worn out gasket complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement worn out LT terminal with bush of existing size for transfomers upto 500 KVA capacity to arrest leackage by opening top cover and refixing the same with replacement of worn out gasket complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Red/ Yellow/ Blue LED indicating lamp (Set of three lamp), 240 Volts, AC complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Red luminous push button with LED indicating lamp and 1 NC Element complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Green luminous push button with LED indicating lamp and 1 NC Element complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 50 KVAR capacitor duty contactor, 240 Volts, AC coil complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of 40 KVAR capacitor duty contactor, 240 Volts, AC coil complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 25 KVAR capacitor duty contactor, 240 Volts, AC coil complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 12.5 KVAR capacitor duty contactor, 240 Volts, AC coil complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 12.5 KVAR cylindrical capacitor, 440 Volts, 3 phase, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 25 KVAR cylindrical capacitor, 440 Volts, 3 phase, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement 12.5 KVAR splendid duty square capacitor, 440 Volts, 3 phase, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 25 KVAR splendid duty square capacitor, 440 Volts, 3 phase, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 50 KVAR splendid duty square capacitor, 440 Volts, 3 phase, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs digital voltmeter 0-500 Volts of size 96mm x 96mm complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs digital ampere meter 0-500 Amps of size 96mm x 96mm complete all as specified and as directed by Engineer-in-Charge.
Repairs/ servicing to 250 KVA DG set (Make- Kirloskar) including radiator servicing, intercooler servicing, general maintenance work such as belt, valve clearance, hose pipe set, bearing greasing connection of terminal, replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as per recommended grade & quality, and testing for smooth running at rated speed complete all as per manufacturer’s specification and as directed by Engineer-in-Charge. Note:- spares required shall be measured and paid separately under respective items as 'Supply only'.
Element fuel filter.
Element lube oil filter.
Corrossion inhibitor.
Fan belt.
Main supply fuel pipe.
Set of O-Ring.
All as per Item No. 29.00 above, but for 82.5 KVA DG Set (for Old HQ SWAC Make- Kirloskar) and replacement of following parts:-
Element fuel filter.
Element lube oil filter.
All as per Item No. 29.00 above, but 160 KVA DG Set (for Comn Flt Ahmedabad Make- Kirloskar Green) and replacement of following parts:-
Element fuel filter.
Element lube oil filter.
Air filter inner.
Air filter outer.
All as per Item No. 29.00 above, but 20 KVA DG Set (for Comn Flt Ahmedabad Make- Mahindra Power) and replacement of following parts:-
Element fuel filter.
Element lube oil filter.
Air filter inner.
Air filter outer.
All as per Item No. 29.00 above, but 10 KVA DG Set (for Sewage lifting pumps Make- Mahindra Power) and replacement of following parts:-
Element fuel filter.
Element lube oil filter.
Air filter inner.
Air filter outer.
Main supply fuel pipe of 10 KVA DG set.
Supply only coolant for cummins DG sets complete all as specified and as directed by Engineer-in-Charge.
Supply only engine Oil 15W40 Valvoline for all DG Sets complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & commissioning in repairs exide battery 12 V, 130 AH, complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & commissioning in repairs exide battery 12 V, 150 AH/ 180 AH, complete all as specified and as directed by Engineer-in-Charge.
Disconnecting/ removing old unserviceable LED lights from sign boards and S&F LED lights of existing size and capacity including all electrical connection complete all as specified and as directed by Engineer-in-Charge.
Disconnecting/ removing old unserviceable Driver from sign boards and S&F new driver of existing size and capacity including all electrical connection complete all as specified and as directed by Engineer-in-Charge.
M&L for installation of sign boards and acrylic sheet background of size 120cm x 60cm including required supporting material i.e. MS clamps, strips nuts, bolts, washers alongwith lettering with sodium sheet material on acrylic sheet with supply & fixing LED T/L fitting of 25 watts - 02 Nos & wiring complete as required as per sample incl 2.50 mtr long GI pipe -02 Nos and taking down old sign board complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & commissioning in repairs controller- HMI211 including display, replacing contactors/ connectors and making all electrical connections good and renewed for DG set 250 KVA (Make-Kirloskar) complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & commissioning in repairs controller- GC 1202 Auto Mains failure control Module including display, replacing contactors/ connectors and making all electrical connections good and renewed for DG set 82.5 KVA (Make-Kirloskar) complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & commissioning in repairs controller - Procom DGC-6D Auto Mains failure control Module including Display, replacing contactors/Connectors and making all electrical connections good and renewed for DG set 160 KVA (Make-Kirloskar Green) complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & comissioning in repairs PLA relay 24 Volt DC for DG set including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & comissioning in repairs PLA relay 110-220 Volt AC for DG set including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying 3 Core flexible copper conductor cable of size 2.5 Sqmm complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & comissioning in repairs Battery charger 24 Volt, 10 Amp (Maxpower or equivelent) for DG set including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & comissioning in repairs SMPS Battery charger 12 Volt, 10 Amp (Maxpower or equivelent) for DG set including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & comissioning in repairs Automatic Voltage Regulator (AVR) for DG sets of capacity from 10 KVA upto 380 KVA of existing make including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 400 Amps, 35/ 36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 250 Amps, 35/ 36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 200 Amps, 35/ 36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 160 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 125 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 100 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 125 Amps, 25 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 100 Amps, 25 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 63 Amps, 25 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Comprehensive Maintenance/ Servicing of existing VCB, 3 phase, 11 KV, 630/ 400 Amps by authorised dealer. The scope of work includes : (a) Calibration of metering system, checking, setting, adjustment of over current relay, earth fault and tripping relay complete all as specified and directed by Engr in charge. The contractor should immediately approach mechanic of authorised dealer as soon as fault occurs/ resetting required. (b) Checking of heater mechanism, IR value, 14 KV hypotest at site, replacement of locking arrangement & testing for smooth functioning at rated voltage. (c) Making all indicator bulbs and push buttons functional at no additional cost. (d) Making all electrical connections to voltmeter and ameter good and ensure the proper functioning of ameters and voltmeters with proper caliberation/ adjustment of voltage and current of outgoing VCB,s with main Incomer VCB. Note:- (1) The contractor should ensure the proper functioning of VCB's and should approach with authorised dealer for carrying of servicing of breaker periodically & when fault/ breakdown occurs. (2) Contractor shall produce all purchase voucher and test certificate before submitting the RAR. (3) The contractor will be responsible for serviceability of VCB for the entire contract period. (4) Unserviceable spare part will be paid and measured separately under respective items of schedule as 'Supply only'.
Supply only 1 Amp PT fuze (set of three fuzes) complete all as specified and as directed by Engineer-in-Charge.
Supply only tripping coil and close coil for healthy functioning of HT VCB complete all as specified and as directed by Engineer-in-Charge.
M&L for opening the HT 11 KV, Bus bar chamber of HT panel/ VCB, cleaning the HT bus bar, inspect the nuts, bolts, bus bar insulator and tighting/ replace with new one if required and heating up for removal of moisture, record its IR value with the help of 5 KV megger and applying thick coating of Z931 strippex B and Z955 Strippex (SL) of stanvac product for preventing from flush over and fire hazard, including replacement of 3/2 mm thick gasket, closing of all holes and charging the same complete all as specified and as directed by Engineer-in-Charge.
M&L for over hauling and secondary injection of over current and earth fault relay of HT VCB 11 KV panel on each multiple setting, readjustment and calibration the same including testing on completion complete all as specified and as directed by Engineer-in-Charge.
M&L for testing of primary injection by artificial load through CTs on each multiple setting of over current and earth fault relay, testing CTs polarities, relay calibration and cordination complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches n.exc. 1.5 mtrs wide and n. exc. 1.5 mtr in depth for laying of electric cables for fixing of poles and stay or for laying pipes (where provided for protection of cables) and getting out trimming the sides forming bottom surface to required level in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm in soft/ loose soil complete all as specified and as directed.
Removal of surplus soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for dry sand cushioning to underground cable with screened, washed river sand, including punning gently complete all as specified and as directed by Engineer-in-Charge. Note:- Thickness after punning will be measured for payment.
Supply and lay burnt brick sub class `B' old size in trenches abouting each other width equal to length of brick etc. complete all as specified and as directed by Engineer-in-Charge.
Supply and laying in trenches in road cross/ floors tube galvanished iron light grade with all fittings for protection of cable of following dia/ bore of pipe:-
40mm bore.
50mm bore.
Supply and laying HT UG cable, XLPE insulated screened PVC badded (ISI Marked), galvanized steel strip or wire, electric power cable (heavy duty) 11000 Volt grade with stranded aluminium conductor of size 95 Sqmm, 3 Core complete all as specified and as directed by Engineer-in-Charge. Note:- Excavation/ earth work, sand cushioning/ brick protection shall be measured and paid separately under respective items of this Schedule.
All as per Item No. 71.00 above, but of size 120 Sqmm.
All as per Item No. 71.00 above, but of size 240 Sqmm.
Supply and laying of LT UG cable, XLPE insulated screened PVC badded (ISI Marked), galvanized steel strip or wire, electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 10 Sqmm, 2 Core. Note:- Excavation/ earth work, sand cushioning/ brick protection shall be measured and paid separately under respective items of this Schedule.
All as per Item No. 74 above, but of size 16 Sqmm, 4 Core.
All as per Item No. 74 above, but of size 25 Sqmm, 3.5 Core.
All as per Item No. 74 above, but of size 35 Sqmm, 3.5 Core.
All as per Item No. 74 above, but of size 50 Sqmm, 3.5 Core.
All as per Item No. 74 above, but of size 70 Sqmm, 3.5 Core.
All as per Item No. 74 above, but of size 95 Sqmm, 3.5 Core.
All as per Item No. 74 above, but of size 120 Sqmm, 3.5 Core.
All as per Item No. 74 above, but of size 185 Sqmm, 3.5 Core.
Taking down old unserviceable cable from trenches/ walls/ pipes/ poles etc. complete of size 10 Sqmm to 16 Sqmm including removing old connection of cable complete all as specified and as directed by Engineer-in-Charge.
All as per Item No. 83 above, but cable size from 25 to 50 Sqmm.
All as per Item No. 83 above, but cable size from 70 to 95 Sqmm.
All as per Item No. 83 above, but cable size from 120 Sqmm to 185 Sqmm.
All as per Item No. 83 above, but cable size 240 Sqmm. Note for item Nos 83 to 87 above:- Excavation/ earth work shall be measured and paid separately under respective items.
Relaying of serviceable cable retrieved from item Nos. 65, 66, 67 after cutting into pieces serviceable portion complete all as specified and as directed by Engineer-in-Charge.
Cable of size of 10 to 16 Sqmm.
Cable of size of 25 to 50 Sqmm.
Cable of size of 70 to 185 Sqmm.
Supply & install, testing & commissioning in repairs LT feeder panel box compartmental type, lockable fabrication with dimension 800mm (H) x 500mm (W) x 500mm (D) made by 3.15 mm thick sheet CRCA approved weather proof design framed on angle iron (40mm x 40mm x 6mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, cable entry with glands, foundation/ grouting on & including PCC as per site requirement including indicator lamps voltmeter and amperemeter with one set of Aluminium Bus bar 200 Amp Cap and fixing the existing changeover switches into that Panel box and making all incoming outgoing electrical cable connections good by fitting new lugs complete all as specified and as directed by Engineer-in-Charge.
M&L for servicing of sliding door motors of Cap - 3 HP operated on 240 V, 50 Hz with replacing of box set - 04 Nos, mechanical seal - 01 No, cut off switch 01 No, bearing 02 Nos, Air filling in tank complete as per site requirement or as directed by Engineer-in-Charge.
M&L for servicing of sliding door gear boxes by replacing of oil seal - 02 Nos, mechanical seal - 01 No, refilling of lubrication oil 15W40, bearing 02 Nos, complete as per site requirement or as directed by Engr-in-Charge.
S&F in repairs cable jointing kit for 11000 Volts grade cable for straight through joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm 3 Core complete as specified and as directed by Engr-in-Charge.
S&F in repairs cable jointing kit for 11000 Volts grade cable for straight through joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm 3 Core complete as specified and as directed by Engr-in-Charge.
S&F in replacement of cable jointing kit for 11000 Volts grade cable for indoor termination, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 Sqmm, 3 Core to 95 Sqmm 3 Core complete as specified and as directed by Engr-in-Charge.
S&F in replacement of cable jointing kit for 11000 Volts grade cable for indoor termination, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 Sqmm 3 Core to 185 Sqmm 3 Core complete as specified and as directed by Engr-in-Charge.
S&F in replacement of cable jointing kit for 11000 Volts grade cable for indoor termination, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 240 Sqmm 3 Core to 300 Sqmm 3 Core complete as specified and as directed by Engr-in-Charge.
S&F in replacement of cable jointing kit epoxy type for 1100 Volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 70 Sqmm 3.5 Core to 120 Sqmm 3.5 Core complete as specified and as directed by Engr-in-Charge.
S&F in repairs cable jointing kit epoxy type for 1100 Volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 25 Sqmm to 50 Sqmm 4 Core complete as specified and as directed by Engr-in-Charge.
S&F in repairs cable jointing kit epoxy type for 1100 Volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 16 Sqmm 4 Core complete as specified and as directed by Engr-in-Charge.
M&L for OCB testing charges of primary Inection testing and Hi-pot testing complete all as specified and as directed.
M&L in replacement of OCB incomer Bus connecting Epoxy bushing with shroud as existing capacity complete all as specified and as directed.
M&L in replacement of SITC OCB HT CT 40/ 5A as existing capacity including removing unserviceable CT complete all as specified and as directed.
M&L in replacement and serviding of OCB troly oil changing complete all as specified and as directed.
S&F in repair/ replacement of galvanized steel earth plate electrode of existing size buried directly in ground vertically to a depth not less than 2.25 mtr deep below Ground level with top edge of the plate not less than 1.5 mtr below normal GI earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt earth lead GI earth strips 32mm x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel and other end of the earth strip connected to test point and protected by GI steel pipe light grade 40mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh including all necessary excavation and earth work completed all as specified and as directed by Engineer-in-Charge.
M&L for construction of earthing chamber/ pit of internal size 600mm x 600mm in repair and making coping for funel with PCC (1:2:4) type B1 (using 20mm gradded stone aggregates) all with MS angle 40mm x 40mm x 4mm frame work duly painted with all corrosive bituminous paint and including RCC slab 50 mm thick in cement concret (1:2:4) type B1, reinforced with XMP (weight not less than 3 Kg per sqm) having lifting arrangement including dismantling old earthing pit complete all as specified and as directed.
M&L for danger notice plate of 1.6 mm thick mild steel sheet viterous enammeled white with letters figures and conventional skulls and bones in single red colour and fixed with MS clamps, bolts and nuts of approved size for LT 20 X 15 cm size complete all as specified and as directed.
M&L for danger notice plate of 1.6 mm thick mild steel sheet viterous enammeled white with letters figures and conventional skulls and bones in single red colour and fixed with MS clamps, bolts and nuts of approved size for HT 25 X 20 cm size complete all as specified and as directed.
M&L for removing the existing damaged test point terminal block and replacing the same with new test point terminal block made out of gun metal or phosphorus bronze of size 75mm x 75mm x 25mm drilled and screwed including 3 hole, 8mm dia, 25mm long hexagonel head with nut and washers etc. complete all as speciified and as directed.
M&L for fixing in position loose/ hanging copper/ aluminium earth strip of any size on wall/ building roof with porcline insulators/ supports of required size complete all as specified and as directed. Note:- Rate of porcline insulator deemed included in rate quoated.
S&F in replacement of copper ballast suitable for CFL 36/ 40 Watts, 4 pin fittings complete all as specified and as directed.
S&F in replacement of ballast SON/ HPSV/ MH copper 70 Watts complete all as specified and as directed.
S&F in replacement of ballast HPSV/ MH copper 150 Watts complete all as specified and as directed.
S&F in replacement of ballast SV/ MH/ MV copper 250 Watts complete all as specified and as directed.
S&F in replacement of ballast SV/ MH/ MV copper 400 Watts complete all as specified and as directed.
S&F in replacement of ballast HPMV copper 125 Watts complete all as specified and as directed.
S&F in replacement of ceramic metal halide lamp 70 watts single ended complete all as specified and as directed.
S&F in replacement of ceramic metal halide lamp 150 Watt single head complete all as specified and as directed.
S&F in replacement of metal halide lamp 250 Watts, single ended complete all as specified and as directed.
S&F in replacement of double headed metal halide lamp 150 Watts complete all as specified and as directed.
S&F in replacement of double headed metal halide lamp 70 Watts complete all as specified and as directed.
S&F in replacement of double headed metal halide lamp 250 Watts, double ended complete all as specified and as directed.
S&F in replacement of HPSV lamp 70 Watts complete all as specified and as directed.
S&F in replacement of HPSV lamp 150 Watts complete all as specified and as directed.
S&F in replacement of HPSV lamp 250 Watts complete all as specified and as directed.
S&F in replacement of HPSV lamp 400 Watts complete all as specified and as directed.
S&F in replacement of HPMV lamp 125 Watts complete all as specified and as directed.
S&F in replacement of ceramic metal halide lamp 400 Watt single head complete all as specified and as directed.
S&F in replacement of igniter electronic 70-400 Watts for SV/ MH lamp complete all as specified and as directed.
S&F in replacement of capacitor suitable for 70 to 400 watt, HPSV/ MH fitting complete all as specified and as directed.
S&F in replacement of porcelain holder for 150/ 250W SV/ MH 80/ 125 MV and 250/ 400 MH complete all as specified and as directed.
S&F in replacement of double end holder 70 To 150 W MH/ 500 W halogen complete all as specified and as directed.
S&F in replacement of double end holder 400 W to 500 W helogen complete all as specified and as directed.
S&F in replacement of drivers for LED street light suitable for 90 x 1.2W fitting complete all as specified and as directed.
S&F in replacement of aviation light including aviation yellow painted die cast aluminum alloy, red colored polycarbonate dome and accessories complete all as specified and as directed.
S&F in replacement of die cast aluminimum flood light with high power LEDs as light source of 30 Watt, LED fittings pre-wired complete all as specified and as directed.
S&F in replacement of die cast aluminimum flood light with high power LEDs as light source of 50 Watt, LED fittings pre-wired complete all as specified and as directed.
S&F in replacement of flood light luminaries, energy saving, long life, of capacity 100 Watt, 6000K pressure dia cast aluminium IP66 LED fitting pre-wired complete all as specified and as directed.
S&F in replacement of flood light luminaries, energy saving, long life of capacity 120 Watt, 6000 K die cast aluminium IP66, high power LED fittings pre-wired complete all as specified and as directed.
S&F in replacement new generation, energy saving, environmetal friendly, long life aesthetically designed aluminium landscape bollard luminaire for diffuser lighting with high power LED of capacity 10 Watts complete all as specified and as directed.
S&F in replacement LED bush and spike light luminaires of IP 65 of 9 Watt complete all as specified and as directed.
S&F in replacement LED post top made in cast aluminium spigot housing with decorative clear acrylic diffuser and IP65 protection of 40 Watt LED complete all as specified and as directed.
S&F in replacement decorative indirect post top light of 45 Watts LED type of IP 65 protection with diecast aluminium body with clear toughned glass diffuser complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of outdoor aesthetically designed LED Street Light of capacity 60 Watt, with pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP 66 protection and impact resistance of IK07 complete all as specified and as directed.
S&F in replacement of outdoor aesthetically designed LED Street Light of capacity 80 Watt, with pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection and impact resistance of IK07 complete all as specified and as directed.
M&L in replacement 30 Watt LED pressure die cast aluminium IP-65 protection road way luminaire with high power LED fix on existing bracket complete all as specified and as directed.
M&L in replacement 35 Watt LED pressure die cast aluminium IP-65 protection road way luminaire with high power LED fix on existing bracket complete all as specified and as directed.
S&F in replacement power contractor of capacity 400 Amps 4 pole suitable for taking proper balancing load and making sefty for any up down voltage complete all as specified and as directed.
All as per Item No. 147 above but 125 Amps.
S&F in repairs 4 pole MCB 32 Amps 415 Volts 10 KA complete all as specified and as directed.
M&L for replacement of looping box (enclosures) made of PVC of size 300mm x 200mm x 155mm comprising of 02 Nos aluminium bus bar 100 Amps rating fixed on porcelain insulators, earthing terminal and one MCB SP 6/ 16 Amp with enclosure complete all as specified and as directed.
M&L in replacement of PVC insulated copper wire with one run three core PVC insulated cable copper conductor 1.5 Sqmm drawn through and including 20mm dia PVC conduit from looping box to street light fitting terminal complete all as specified and as directed. Note:- Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one unit.
M&L for painting of steel tubular pole 9 mtr long complete and mild steel work such as cross arms, clamps, nuts, bolts, street light brackets etc with one coat of aluminum paint including preparation of surfaces complete all as specified and as directed.
All as per Item No. 152 above, but garden pole 2.5 meter long.
M&L for painting of PCC pole 9 mtr long complete and mild steel work such as cross arms, clamps, nuts, bolts, street light brackets etc with one coat of aluminum paint including preparation of surfaces complete all as specified and as directed.
M&L for writing letters or figures (Block, Roman, Italic or Indian) n. exc. 30 cm high writing pole no with black paint having existing letter size with the help of stencil cut for letters & figures complete all as specified and as directed.
M&L in replacement for mounting bracket forming 'L' shape having an interior angle of 120 degree made out of GI pipe light grade 25mm dia for fixing to street light fittings on the poles not less than 1.5 meter long duly painted with aluminium paint two coats complete all as specified and as directed.
ARTI CONSTRUCTION
Dighard Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .