Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹30.7 L+₹3.7 L (13.7%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹58,000
Closing Date
14 Dec 2021, 6:00 pmClosed
GE (AF) CHILODA
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
COMPREHENSIVE DAY TO DAY REPAIR AND MAINT OF INTERNAL ELECTRIFICATION SERVICES AND REPAIR AND MAINT OF ELECTRIC SUPPLY, WATER SUPPLY INSTALLATIONS AND ALLIED WORKS
2021_MES_489023_1
8974/21-22/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Gandhinagar
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹58,000
Yes
28 Jan 2022
18 Nov 2021
16 Dec 2021
18 Nov 2021
14 Dec 2021
2 Dec 2021
Amount
Taking down carefully copper/ aluminum point wiring of any size and description (Light, fan, socket, power and bell) including fixture and fittings such as switches, sockets, ceiling roses, lamp, holder, regulators, sockets light fittings etc, removing material for taking credit and making good disturbed surface of walls, floors, etc. complete all as specified and as directed.
M&L for point wiring for one light point or one fan point or one bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated and unsheathed cable, 1100 Volts grade drawn through existing concealed PVC conduit and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly with incl 3mm thick laminated hylam sheet and factory made GI sheet sunken box complete all as specified and as directed.
All as per Serial Item No. 2 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 Amps on same board.
All as per Serial Item No. 2 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on independent board.
All as per Serial Item No. 2 here-in-before but point wiring for one 6 pin switch socket outlet combination, 5/ 15 Amps (independent) with using 2.5 Sqmm (nominal area) copper PVC insulated unsheathed stranded copper conductor as continuous earth wire on independent board for one socket outlet 3 pin 15 Amps.
S&F switch piano flush type, 5 Amps, single pole, one way, 230 Volts AC complete all as specified and as directed.
S&F for socket outlet, 5 pin, 5 Amps, flush type, 230 Volts AC complete all as specified and as directed.
S&F for switch socket outlet combination, 5 pin, 5 Amps, flush type, 230 Volts, AC complete all as specified and as directed.
S&F for switch socket outlet combination, multipurpose, 3 pin, 15 Amps and 3 pin 5 Amps controlled by one switch, flush type, 230 Volts, AC complete all as specified and as directed.
S&F for ceiling rose surface bakelite, three terminals complete all as specified and as directed.
S&F fan regulator step type suitable for ceiling fans, prewired 230 Volts, AC, 50 Hz supply 60/ 100 Watt complete all as specified and as directed.
S&F in repair modular bell push 6 A, 1 module complete all as specified and as directed.
S&F in repair modular switch 1 way, 6 A, 1 module complete all as specified and as directed.
S&F in repair modular socket, 6 A - 2/3 pin combined, 2 module complete all as specified and as directed.
S&F in repair socket 6A/ 16A - 2/3 pin, combined, 2 module complete all as specified and as directed.
S&F in repair fan step regulator, 120 W - 2 module complete all as specified and as directed.
S&F in repair bell multi music type complete all as specified and as directed.
S&F in repair white cover plate with frame, 2 module complete all as specified and as directed.
S&F in repair white cover plate with frame, 3 module complete all as specified and as directed.
S&F in repair white cover plate with frame, 4 module complete all as specified and as directed.
S&F in repair white cover plate with frame, 6 module complete all as specified and as directed.
S&F in repair white cover plate with frame, 8 module complete all as specified and as directed.
M&L for point wiring for one light or one fan or one bell point controlled by one switch with using 1.5 Sqmm single core FRLS PVC insulated unsheathed multi stranded copper conductor cable 1100 V grade drawn through with incl PVC casing in capping/ conduit (size of as required at site but not less than 20mm) with accessories like bends tees, junction boxes and terminal boxes for mounting fittings etc. fixed on recessed in wall or ceiling etc including 1.5 Sqmm single core FRLS PVC insulated but unsheathed multistrandard copper conductor cable 1100 V grade as earth continuity wire connected to common earth dolly with incl PVC board size as required at site complete all as specified and as directed.
All as per Serial Item No. 23 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 Amps on same board complete all as specified and as directed.
All as per Serial Item No. 23 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on independent board complete all as specified and as directed.
All as per Serial Item No. 23 here-in-before but point wiring for one 6 pin switch socket outlet combination, 5/ 15 Amps (independent) with using 2.5 Sqmm (nominal area) copper PVC insulated unsheathed stranded copper conductor as continuous earth wire on independent board for one socket outlet 3 pin 15 Amps complete all as specified and as directed.
S&F in repair bell push flush type, 5 Amps, Single pole, 230 Volts, AC complete all as specified and as directed.
S&F in repair call bell AC, 230 Volts, single pole complete all as specified and as directed.
S&F in repair regulator step type suitable for ceiling fans, prewired 230 Volts, AC, 50 Hz supply 60/ 100 Watt complete all as specified and as directed.
S&F in repair switch piano type, 230 Volts, 5 Amps, single pole complete all as specified and as directed.
S&F in repair switch piano type, 230 Volts, 15 Amps, single pole complete all as specified and as directed.
S&F in repair socket outlet 2 in 1, 3 pin, 5 Amps flush type, 230 Volts complete all as specified and as directed.
S&F in repair socket outlet 2 in 1, 3 pin, 6 and 16 Amp, flush type complete all as specified and as directed.
M&L for in replacement of sub main wiring using two single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 4.0 Sqmm of 1100 Volts Voltage rating drawn through and including PVC casing caping of size not less than 25mm with standard accessories, alongwith one run of FRLS PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm as earth continuity conductor complete all as specified and as directed. Note:- Two run of single core FRLS PVC cable with one run of earth conductor and conduit shall be measured as one unit.
All as per Serial Item No. 34 here-in-before but sub main wiring with using two single core 6.0 Sqmm FRLS PVC insulated stranded copper conductor cable.
S&F in repairs PVC insulated aluminium stranded conductor of size 10.0 Sqmm twin core flat or circular cable 1100 Volts grade, heavy duty cable, served with inner sheathed cable complete all as specified and as directed.
S&F in repairs sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links (without MCB's) 4 ways, VTPN complete all as specified and as directed.
Supply, fixing, connecting and testing in repairs sheet metal enclosures double door type for using MCBs suitable for single pole and neutral, 12 way with having copper bus bars suitable for 200 Amps rating complete all as specified and as directed.
All as per Serial Item No. 38 above but 8 way.
All as per Serial Item No. 38 above but 4 way.
All as per Serial Item No. 38 above but 16 way.
Supply, fixing, connecting and testing in repairs sheet metal enclosures double door type for using MCBs suitable for single pole and neutral, 4 way, TPN with having copper bus bars suitable for 200 Amps rating complete all as specified and as directed.
S&F in repair/ replacement MCB triple pole and neutral (TPN), 40 to 100 Amps, 240 Volts, 10 KA, ‘C’ series, with proper size lugs and connections complete all as specified and as directed.
S&F in repair/ replacement MCB Triple pole 32 to 63 Amps, 240 Volts, 10 KA, ‘C’ series, with proper size lugs and connections complete all as specified and as directed.
S&F in repair/ replacement MCB single pole and neutral (SPN), 20 to 40 Amps, 240 Volts, 10 KA, ‘C’ series, with proper size lugs and connections complete all as specified and as directed.
S&F in repair/ replacement MCB single pole (SP) 6 to 32 Amps, 240 Volts, 10 KA, ‘B’ series, with proper size lugs and connections complete all as specified and as directed.
S&F in repair/ replacement industrial type sheet metal enclosures with a two pin and earth plug and socket, 250 Volts with including 20 Amp SP MCB complete all as specified and as directed.
S&F in replacement surface and wall mounted 1x20 Watt LED batten, aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver complete with all accessories internally pre wired and including connection up with twin core flexible copper conductior cable complete all as specified and as directed.
S&F in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10/11 watt 220 V, AC decorative type with driver holder and LED lamp including connecting up with twin core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in replacement round or square shape 15 Watt 220 Volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in replacement LED luminaire 600mm x 600mm, 35/ 36 Watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
S&F in replacement LED light fitting 1x9 W/ 1x10 W bulkhead luminaires including LED light holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in replacement for LED street light fitting 30 Watt, 230 V, AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S&F in replacement for LED street light fitting 90 Watt, 230 V, AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S&F in replacement for decorative, wall mounting, brushed nickel finish fixture with dual Opal Glass diffuser suitable for LED lamp B22 Base complete all as specified and as directed.
S&F in replacement intrigal decorative LED bollard with opal acrylic 9 Watt LED 3000K with IP 65 protection as per existing sample complete all as specified and as directed.
S&F in repair decorative spike focus light luminaries 30 Watt, 5000K COB LED fittings pre-wired as per existing sample complete all as specified and as directed.
S&F in replacement recessed mounting PDC AL body swivel type round COB 15 Watt LED downlight including LED driver as per existing sample complete all as specified and as directed.
S&F in replacement for high light intensity empowered color changing and monochromatic LED under water fountain light with polarized light design and intelligent logarithmic control technology as per existing sample complete all as specified and as directed.
S&F in replacement water proof led power supply controler (SMPS) of capacity 500 Watt, input 230 Volt and out voltage DC 12 V, +- 5%, suitable for control fountain LED lights as per existing sample complete all as specified and as directed.
S&F in repair ultra bright LED polycarbonate tubelight rod 18 Watt with very high efficacy complete all as specified and as directed.
S&F in replacement decorative coloured flood light, suitable for focasing of tree/ buildings of capacity 100 Watt, 240 Volt, 50 Hz complete all as specified and as directed by Engr-in-Charge.
S&F in replacement LED strip suitable for decorative 50 meter LED rope light, water proof, RGB colour with adaptor suitable for 180 Volt to 280 Volt and as directed by Engr-in-Charge.
S&F in replacement LED bulb retrofit type 9 Watt, efficacy 100 Lm/W suitable for 180 Volt to 280 Volt. E22 & E27 type complete all as specified and as directed.
S&F in replacement LED bulb retrofit type12 Watt, efficacy 100 Lm/W suitable for 180 Volt to 280 Volt complete all as specified and as directed.
S&F in replacement LED bulb retrofit type15 Watt, efficacy 100 Lm/W suitable for 180 Volt to 280 Volt complete all as specified and as directed.
S&F in replacement LED bulb retrofit type 5 Watt, Red/ Green colour suitable for 180 Volt to 280 Volt complete all as specified and as directed.
S&F in replacement 36/ 42 Watt LED driver suitable for 180 to 275 Volt LED light fitting complete all as specified and as directed.
S&F in replacement 15/ 18 Watt LED driver suitable for 180 to 275 Volt LED light fitting complete all as specified and as directed.
S&F in replacement 80 Watt LED driver suitable for 180 to 275 Volt LED light fitting complete all as specified and as directed.
S&F in repair electronic ballast suitable for 1x36/ 40 Watts complete all as specified and as directed.
S&F in replacement of decorative post top lantern doom made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base as per existing sample complete all as specified and as directed.
S&F in repair light fitting 1x30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as per shown in electrical plate No. 5 of MES Schedule Part-I with connected to earth test point main switch board with including necessary earth work and Pre- cast RCC earth pit with cover and including dismantling/ taking out of old unserviceable earthing of any position complete all as specified and as directed.
All as per Serial Item No. 74 here-in-before but using galvanised iron strip 32×6mm as earthing lead.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. of 4.0mm dia galvanised iron or steel wire complete all as specified and as directed.
All as per Serial item No. 76 here-in-before but using 20x3mm copper strip.
S&F in replacement of GI pipe 40mm dia light grade for earth strip protection complete all as specified and as directed.
M&L for replacement of test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed.
M&L for colour coding of earthing pit cover with the following colour Red for Chemical earthing and yellow for conventional earth pit complete all as specified and as directed.
M&L for recharging of chemical earth pit by using liquid chemical earthing solution (not less than 10 Kg) and mixing with water and filling into the chemical earth pit to achieve result earth value less than 1 Ohm, complete all as specified and as directed.
M&L for recharging of conventional earth pit by using salt (not less than 20 Kg) and mixing with water and filling into the earth pit to achieve result earth value less than 5 Ohm, complete all as specified and as directed.
S&F precast RCC earth pit with cover incl watering funel and wire mesh as per sample and including dismantling/taking out of old unserviceable of any position complete all as specified and as directed.
Comprehensive maintenance/ servicing of RO plant 50 Ltr/ 60 ltr capacity including washing, cleaning of sedimentation filter, disinfection process, servicing of pressure pumping set, and if any other required minor spare parts i.e. RO connection pipe with accessories, RO plug charger, wire, screw, nut, bolts etc at site for smooth functioning of RO plant shall be provided by contractor without any cost. Seting the PH, TDS of water at permissible level including testing of water after repair of RO plant complete the satisfaction of Engr-in-Charge. Note:- (a) Defective major components/spares if required to be replaced shall be measured and paid as 'supply only' under respective items 91 to 104 here-in-after and labour element included in this item for replacement. (b) The rate quoted by the tenderer includes cost of maint/ servicing of above said each plant ones in a quaterly visits and emergency callout as when required till the date of completion of work. (c) Servicing should be done by OEM/ authorized agency and not by any local mechanic.
Supply only sediment filter as per exiting sample for 60 Ltr RO plants.
Supply only sediment filter as per exiting sample for 50 ltr RO plants.
Supply only RO membrane as per exiting sample for 50 Ltrs RO plant.
Supply only RO membrane as per exiting sample for 60 Ltrs RO plant.
Supply only RO membrane housing as per exiting sample for 50/ 60 lts RO plant.
Supply only carbon filter as per exiting sample for 50/ 60 ltrs RO plant.
Supply only low pressure/ High pressure DC switch for 60/ 50 RO plant.
Supply only stainer as per exiting sample for 50/ 60 Ltrs RO plant.
Supply only SMPS as per exiting sample for 50/ 60 Ltrs RO plant.
Supply only antiscalant chemical for 50/ 60 ltrs RO Plant.
Supply only solenoid valve as per exiting sample for 60/ 50 ltr RO plant.
Supply only TDS adjuster as per exiting sample for 50/ 60 Ltrs RO plant.
Supply only booster pump 24/ 48V DC as per exiting sample for 50/60 Ltrs RO plant.
Supply only controler as per exiting sample for 50/ 60 ltr RO plant.
Disconnecting electrically, taking down and removing carefully the existing ceiling fans, exhaust fans, wall bracket fans, etc. of any description, and any position for repairs/ servicing/ overhauling/ painting/ numbering, etc. including dismantling and opening of the fans, checking serviceable parts, overhauling by necessary cleaning, oiling, greasing, etc. and fixing the serviceable parts in position, removing and replacement of defective/ unserviceable parts if any with new parts, re-assembling the fans, making necessary adjustment and proper alignment of blades, hanging/ fixing the repaired fans in position including provision of suitable three core flexible copper wire upto 1.0m length and providing new safety pins and lock nuts at the same position and testing at site to the entire satisfaction of Engineer-in-Charge complete all as directed.
Note:- (a) Rewinding, replacement of unserviceable parts such as bearing, GM bush, capacitor shall be measured and paid separately under respective items. (b) Contractor’s quoted rates is deemed to include for inspection/ checking the serviceability of the fans in position or by taking down as per site requirement, removing the damaged unserviceable/ broken parts, fixing the new parts as required, fixing the fans in same position or the other, connecting the fan with electric source and testing complete.
M&L for rewinding of ceiling fan motor with appropriate size super enameled copper wire including insulating material such as illuminous paper, letherized paper, cotton tape, glass sleeving, insulating varnish, etc. connecting to electric source and testing on full load to the entire satisfaction of Engineer-in-Charge. Note:- Taking down & refixing of ceiling fan after winding, painting and replacement of bearing, bush, capacitor etc. will be measured & paid separately.
All as per Serial Item No. 100 here-in-before but for exhaust fan motor of 300/ 450mm sweep any type.
All as per Serial Item No. 100 here-in-before but for wall fan motor of 400mm sweep any type.
All as per Serial Item No. 100 here-in-before but for pedestal or air circulator fan motor of any sweep.
S&F in replacement ceiling fan capacitor of 2.5 MFD capacity complete all as specified and as directed.
S&F in replacement exaust fan capacitor 3.25/ 4.0 MFD capacity complete all as specified and as directed.
S&F in replacement of ball bearing suitable size to the existing ceiling fan, exaust fan, wall fan of any type complete all as specified and as directed.
S&F in replacement of hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable to ceiling fans down rods complete all as specified and as directed.
M&L for painting of old ceiling fans/ exhaust fan of any size complete, in situ with synthetic enamel paint by praying including filling cavities with filler, one coat after cleaning all dust etc. writing the fan numbers/ MES numbers etc with black paints complete all as specified and as directed.
S&F in replacement wall/ exhaust fan blade any sweep as per existing sample complete all as specified and as directed.
S&F in replacement ceiling fan blade any sweep as per existing sample complete all as specified and as directed.
S&F in replacement ventilation fan PVC 200/ 300 mm sweep complete all as specified and directed.
S&F in replacement MS 300mm long ceiling fan down rod 20mm dia as per sample complete all as specified and directed.
S&F in replacement thermostat for water heater (Geyser) 25/ 50 Ltrs capacity as per sample complete all as specified and directed.
S&F in replacement heating element for water heater (Geyser) 25/ 50 Ltrs capacity as per sample complete all as specified and directed.
S&F new multi stranded copper conductor cable of size 1.0 Sqmm, 3 Core including taking down of existing unserviceable one complete all as specified and directed.
S&F in replacement geysers PVC pipe connection hot/ cold type, 15mm bore, 600mm long having brass nuts and washers on both ends complete all as specified and directed.
Testing of bore well water/ RO water to analysis the following parameter as per IS 10500 : 2000 through Govt. approved agency:- (a) Physicochemical parameters of water/ eflluent sample (b) Bactoriological test of water sample. (c) Metals (Expect Hg, As & Se). (d) Pesticides.
Servicing and non comprehencive annual maintenance of RO plant of 5000 ltr/ hr capacity (Make-ion exchange) with authorised service centre of ion exchange. Note:- 1. This include visit of the technician of ion excahnge every month in any working days and look the performance, back wash the filter at regular intervals, check the anti scalant and add the chemical as required,cleaning of sediementation filter, cleaning of cartridge and membrane, check of control panel and system pressure and RO element for proper operation of the system, seting the PH, TDS of water at permissible level including testing of water after repair of RO plant complete the satisfaction of Engr-in-Charge.
(a) Defective major components/ spares if required to be replaced shall be measured and paid as supply only under respective Item Nos. 125 to 137 here-in-after and labour element included in this item for replacement. (b) The rate quoted by the tenderer includes cost of maint/ servicing of above said each plant ones in a month visits and emergency callout as when required till the date of completion of work. (c) Servicing should be done by OEM/ authorized agency and not by any local mechanic.
Supply only Jumbo filter 20" for 5000 Ltr RO plant complete all as specified and as directed.
Supply only anti-scalanent chemical 8211 for 5000 Ltr RO plant complete all as specified and as directed.
Supply only membrane hydra 8040 for 5000 Ltr RO plant complete all as specified and as directed.
Supply only UV lamp for 5000 Ltr RO plant complete all as specified and as directed.
Supply only UV system for 5000 ltr RO plant complete all as specified and as directed.
Supply only multi port valve suitable for existing 5000 Ltr plant complete all as specified and as directed.
Supply only low/ high pressure switch suitable for 5000 ltrs RO plant complete all as specified and as directed.
Supply only carbon filter suitable for 5000 ltrs RO plant complete all as specified and as directed.
Supply only solenoid valve for 5000 Ltr RO plant complete all as specified and as directed.
Supply only multi filter housing suitable for existing 5000 ltr RO plant complete all as specified and as directed.
Supply only dosing pump suitable for existing 5000 ltr RO plant complete all as specified and as directed.
Supply only control panel suitable for existing 5000 ltr RO plant complete all as specified and as directed.
Supply only vessel 1354 of existing make suitable for 5000 ltrs RO plant complete all as specified and as directed.
S&F in replacement of old unserviceable 15mm bore "medium grade" galvanised iron pipes with all fittings complete to walls and ceilings or laid in floors/ trenches complete all as specified and as directed. Note:- Excavation/ earth work will be measured and paid separately under respective items.
All as per Item No. 132 here-in-before but for 20mm bore GI pipes.
All as per Item No. 132 here-in-before but for 25mm bore GI pipes.
All as per Item No. 132 here-in-before but for 50mm bore GI pipes.
All as per Item No. 132 here-in-before but for 80mm bore GI pipes.
S&F in replacement of old unserviceable 20mm dia CPVC pipes SDR 11 with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and as directed. Note:- Excavation/ earth work will be measured and paid separately under respective items.
All as per Item No. 137 here-in-before but 25mm bore CPVC pipes SDR 11 with fittings.
S&F in repairs gun metal foot valve 100mm size complete all as specified and as directed.
Taking out the broken, rusted, valve pit cover of any size and M&L for fixing valve pit cover of suitable size to existing made of 3mm thick MS sheet/ plate including provision of hinges, handle and locking arrangement including 40mm x 40mm x 4mm iron frame fixed or top of valve pit, including two coat of anti-corrosive paint over a coat of red oxide primer complete all as specified and as directed.
M&L for preparation of pipe line of DI or GI surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete with showing arrow in water flowing direction in white colour complete all as specified and as directed.
Repair to submersible pumping set capacity 25 HP, 440 V, 3 Phase discharged 510 LPM at 123 Metre head consisting of following:- Opening of submersible motor and cutting to burnt winding and cleaning to slots by cleaning and repairs to damage starter etc, rewinding to submersible motor with suitable size of superior quality copper winding wire insulating materials all as directed by Engineer-in-Charge. (a) Replacement of thrust bearing – 01 No. (b) Replacement of bush . (c) Re-assembling and transporting to Pump House, lowering pump and testing complete. Dismantling of submersible pump set all as directed and replacement of the following items:- (i) Replacement of neck ring – 05 Nos. (ii) Replacement of brass bushes – 8 Nos. (iii) Replacement of shaft bush - 02 Nos. (iv) Replacement of impeller - 05 Nos.
M&L for disconnecting electrical/ mechanical connection and taking out submersible pump set from existing bore well approx depth varying from 110 m to 130 m with all accessories and transporting to authorized workshop for rewinding and overhauling of sumbermersible pump and after overhauling/ rewinding, re-lowering the pump set in bore well with all accessories, including making connection with existing starter and testing to ensure efficient and smooth functioning to obtain required discharge, etc complete all as specified and as directed.
S&F in replacement 100mm bore heavy grade MS/ GI column pipe in 3 metre length with both side flange ends complete all as specified and as directed.
Comprehensive maintenance and servicing of chlorine dosing equipment self priming, having discharge capacity up to 5 Ltrs/ Hour of any make and carry out repair/ replacement of defective minor spares parts i.e. spring, oil seal, pan head screw, circlip, stroke knob and nut, bolt and washer etc. including cleaning, washing/ reassembling the plants and testing after repair complete all as specified and as directed by Engr-in-Charge. Note:- (i) Defective major components/ spares if required to be replaced shall be measured and paid as supply only under respective items here-in-after and labour element included in this item for replacement. (ii) All items being spare parts as under will be replaced as required as per cat part or as per existing sample to shoot the equipment for smooth functioning. (iii) The rate quoted by the tenderer includes cost of maint/ servicing of above said each plant ones in a quarterly visits and emergency call out as when required till the date of completion of work.
Supply only PVC diaphragm with 'O' ring head for chlorine dosing.
Supply only suction valve up to 5 Ltrs/ Hr for chlorine dosing pump.
Supply only discharge valve upto 5 Ltrs/ Hr for chlorine dosing pump.
Supply only non return valve suitable for dosing pump.
S&F in repairs gun-metal, globe or gate valves of size 15mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed
S&F in repairs gun-metal, globe or gate valves of size 20mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed
S&F in repairs gun-metal, globe or gate valves of size 25mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed
S&F in repairs gun-metal, globe or gate valve of size 50mm dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed
S&F in repairs sluice valve of size 100mm dia and class PN 1.6, with iron wheel head, screwed both ends GI pipe and fixed complete all as specified and as directed
S&F in repairs sluice valve of size 150mm dia and class PN 1.6, with iron wheel head, screwed both ends DI pipe and fixed complete all as specified and as directed
M&L for repairs to joint leakage of DI pipe line of 100mm to 150mm dia, by cocking and inserting extra lead/ gasket/ rubber sheet clamp, nut bolts etc. and any other material required at site for making good/ leakless the existing joint, including necessary excavation and earth work, returning filling after testing the joint complete all as specified and as directed.
M&L for repairs in leakage/ blocked GI water tubing of size 15mm to 40mm by using pipe nipple, union, coupling etc. and any other material required at site for making good/ leakless the existing joint, including necessary excavation and earth work, returning filling after testing the joint complete all as specified and as directed.
M&L for repairs in leakage/ blocked GI water tubing of size 50mm to 80mm by using pipe nipple, union, coupling, etc. and any other material required at site for making good/ leakless the existing joint, including necessary excavation and earth work, returning filling after testing the joint complete all as specified and as directed.
M&L in replacement for 150mm dia CI/ DI pipe with DI pipe (spun) 150mm dia class K7 in any length with special fitting laid in trenches/surface complete all as specified and as directed. Note:- Earth work will be measured and paid separately under relevant item of sch.
M&L for making serviceable old unserviceable motor starter of any type carrying out repair and with replacement of defective spare parts such as timer, relay, connector, burn contol copper cable, insulator, terminal block, copper thimbles, etc or if any other required minor spare parts at site for including testing to ensure efficient and smooth functioning of starter complete all as specified and as directed.
Cleaning of fire water static water tank of capacity 15000 litre at Sector-27 area, by draining out storage water completely with mud pump or throwing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with depositing distance not exceeding 50 metre complete all as specified and as directed.
Cleaning of clear water semi underground sump of capacity 25000 Gallon at Sector-27 pumphouse, by draining out storage water completely with mud pump or throwing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of potassium permaganate including writing date of cleaning with white synthetic enamel paint and removing sludge scale mud etc to a distance not exceeding 50 metre and deposting complete all as specified and as directed.
Cleaning of RCC overhead reservoir of capacity 50000 Gallons at 20 metre staging, by draining out storage water completely with mud pump or throwing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc. with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of potassium permaganate including writing date of cleaning with white synthetic enamel paint and removing sludge scale mud etc to a distance not exceeding 50 metre and depositing complete all as specified and as directed.
M&L for disconnecting and taking up/ down 7.5/ 10 HP capacity centrifugal/ mono-block pump set of any type from foundation and transporting to authorized workshop carry out repairs such as replacement of pump bearing and overhauling including replacement of minor unserviceable components/ spares like 'O' rings, Oil seal, Mechanical seal, pump gland, casing ring, gasket packing and greasing, welding, metaling, turning, polishing, lathe work etc. along with removing existing burnt/ short circuited winding wire complete, cleaning of core grooves and surfaces, rewinding the motor with superior quality enameled copper winding wire of suitable gauge, numbers of turns and coils including insulating material such as sleeves, lathorised fibe glass, cotton/ PVC tape varnishing etc, reassembling, refixing and testing the motor at site on full load complete all as specified and as directed by Engr-in-Charge.
S&F in repairs 3 layer borosilicate glass tube (58 mm OD,1800mm length) suitable for tube type solar water heaters complete all as specified and as directed.
S&F in repairs heat reistance silicon ring (58 mm OD) suitable for tube type solar water heaters complete all as specified and as directed.
S&F in repairs of 3 KW electric back up heater with thermostat (ISI approved) with pressure release valve 31.75mm dia complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/ loose soil for taking up/ laying cable/ pipe etc completed all as specified and as directed.
Returning, filling including spreding, leveling watering and well ramming in laying not exc. 25cm for soft/ loose soil complete all as specified and as directed.
Removal of excavated material at a distance not exc. 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point for soft/ loose soil complete all as specified and as directed.
M&L for dry sand cushioning to underground cable with screened, washed river sand, including punning gently complete all as specified and as directed. Note:- Thickness after punning will be measured for payment.
Supply and lay burnt brick sub class `B' old size in trenches abouting each other width equal to length of brick etc. complete all as specified and as directed.
Laying only burnt bricks (old size) retrieved from respective items, laid in trenches as cable protection complete all as specified and as directed.
Supply and laying in trenches in road cross/ floors tube galvanished iron light grade 40mm bore with all fittings for protection of cable complete all as specified and as directed.
Labour only for boring under road/ drain by manual method for inserting the light grade pipe GI tubing up to 50mm dia cable protection complete all as specified and as directed by Engineer-in-Charge.
Disconnecting, taking out and removing old existing unserviceable underground, LT/ HT cable of any description and in any position complete including taking down unserviceable protection pipe etc. for LT aluminium conductor cable of size 10 to 35 Sqmm of any core complete all as specified and directed by the Engineer-in-Charge
All as per Item No. 176 above but LT aluminium conductor cable of size 50 to 95 Sqmm, 3.5 Core.
All as per Item No. 176 above but HT aluminium conductor cable of size 95 Sqmm, 3.0 Core.
Laying only serviceable XLPE/ PVC insulated, armoured, heavy duty, aluminum conductor cable of 1100/ 11000 Volts grade of any description and any make laid in trenches/ ducts, floors, on pole, walls etc. for LT U/G cable of 10 Sqmm to 35 Sqmm any core complete all as specified and as directed by the Engineer-in-Charge. Note:- (i) Old retrieved cables received in serviceable condition from taking down shall be used in the work. (ii) Additional quantity of cable, if any required, for replacing the defective portion of cable retrieved from dismantling/ taking out, shall be measured and paid separately under respective items.
All as per Item No. 179 above but LT U/G cable of 50 Sqmm to 95 Sqmm, 3½ Core.
All as per Item No. 179 above but HT U/G cable of 95 Sqmm, 3 Core.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 Volts, earthed grade cross sectional area 95 Sqmm complete all as specified and as directed.
Supply, laying and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 95 Sqmm. 3.5 Core complete all as specified and as directed. Note:- Excavation, earthwork, will be measured and paid separately under respective items of this schedule.
All as per Item No. 183 above but cable of size 50 Sqmm, 3.5 Core.
All as per Item No. 183 above but cable of size 25 Sqmm, 3.5 Core.
All as per Item No. 183 above but cable of size 16 Sqmm, 4 Core.
All as per Item No. 183 above but cable of size 10 Sqmm, 4 Core.
M&L for searching fault by mannualy/ machine of 50 Sqmm to 185 Sqmm unservieable LT underground cable 1100 Volt grade by excavating of soil and taking out old bricks, after tracing out defect i.e. cutting and jointing cable with suitable size straight through joint and after testing with megger etc. complete all as specified and as directed. Note:- (a) If extra suitable size cable required for straight through jointing (the extra cable required length upto 3 RM) rate shall be deemed into this item rate. (b) Earth work more than two running meter shall be measured and paid separately. (c) Straight through joints will be measured and paid separately.
M&L for searching fault by mannualy/ machine of 95 Sqmm unservieable HT underground cable 11000 volt grade by excavating of soil and taking out old bricks, after tracing out defect i.e. cutting and jointing cable with suitable size straight through joint and after testing with megger etc. complete all as specified and as directed. Note:- (a) If extra suitable size cable required for straight through jointing (the extra cable required length upto 3 RM) rate shall be deemed into this item rate. (b) Earth work more than two running meter shall be measured and paid separately. (c) Straight through joints will be measured and paid separately.
S&F epoxy jointing kit for straight through joints of LT armoured aluminium conductor cable size 95/ 120 Sqmm, 3.5 Core, 1100 Volts grade cable with epoxy jointing materials complete all as specified and as directed.
All as per Item No. 190 above but for LT armoured aluminium conductor cable size 50/ 70 Sqmm, 3.5 Core, 1100 Volts grade cable.
All as per Item No. 190 above but for LT armoured aluminium conductor cable size 25/ 35 Sqmm, 3.5 Core, 1100 Volts grade cable.
All as per Item No. 190 above but for LT armoured aluminium conductor cable size 10/ 16 Sqmm, 4 Core, 1100 Volts grade cable.
S&F cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 Core, XLPE armoured aluminium conductor cable of size 95 Sqmm to 120 Sqmm complete all as specified and as directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 Core, XLPE armoured aluminium conductor cable of size 95 Sqmm to 120 Sqmm complete all as specified and as directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3 Core, XLPE armoured aluminium conductor cable of size 95 Sqmm to 120 Sqmm complete all as specified and as directed.
M&L for preparation of old painted surface of steel tubular pole (upto 9 meter long above coping) with MS clamp and applying two coat of aluminium paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400mm height with one synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted surface of LT RCC pole (up to 6.10 metre height above coping), applying two coat snowchem cement base paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400mm height with one synthetic enamel paint, rewriting pole No by painter with enamel paint, and painting the existing MS clamp with one coat aluminum paint complete all as specified and as directed.
Supply and paste fluorescent type reflective tape of superior quality width 450mm (three strips, each 150mm wide and 600mm long of colour white, sky blue, white), paste on steel tubular pole on outer circumferences including removing old tape complete all as specified and as directed.
M&L for writting of Pole Nos. on existing pole with stencil out with white colour in sky blue colour background of 80 mm hight around the radius of pole and complete all as specified and as directed by Engr-in-Charge.
S&F in repairs timer switch Digital type 24 hours with 15 min and 30 min, 30/ 100 Amp contact rating 230 Volts, AC, 50 Hzs suitable to existing sample for street lights and all as specified and as directed by Engr-in-Charge.
S&F in repairs 3 pole power contactor AC 3 rating 20/ 32 Amps with Aux Contactors 2NO+2NC complete all as per existing sample.
S&F in repairs 3 pole power contactor AC 3 rating 40/ 50 Amps with Aux Contactors 2NO+2NC complete all as per existing sample.
S&F in repairs MCB single pole with neutral, 6 to 32 Amps, 250 Volts with ‘C’ curve, fixed in existing PVC box including connecting complete all as specified and as directed.
S&F in repairs MCB TPN, 32 to 63 Amps, 250 Volts with ‘C’ curve, fixed in existing PVC box including connecting complete all as specified and as directed.
Disconnecting the existing unserviceable PVC box and S&F PVC box of outside size 350mm x 250mm x 150mm including 4 Nos. of bus bar strip of aluminium of size 25x4 mm suitable for 440 Volts of suitable amps rating including 1 No. MCB SPN, 6 to 32 Amps, 250 Volts with 'C' curve, to be fixed on pole with clamp complete all as specified and as directed.
Dismantling and taking down defective/ unserviceable LED street lights fitting and flood lights of any type from electric pole and repairing/replacing the unserviceable parts i.e. light fitting, drivers and wire etc. refitting the same after testing and fixing the serviceable light fitting on pole complete all as specified and as directed.
S&F in repairs 200 Watt LED flood light with pressure die-cast aluminium housing, complete with all accessories, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP : 65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purposelighting Turo Floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 Protection fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and as directed.
S&F in repairs LED street light fitting 80/ 90 Watt sealed optic luminaire with housing made of die-cast aluminium with smooth finish powder coated for better environmental protection complete all as specified below:- (i) The fixture shall be designed so as to ave lumen maintenance of at least 70% at the end of 70000 hours. (ii) The luminaire should be operable with auto adjustable 120-240 Volt supply using the same driver. Ambient temperature at LED should not be more that 70 degree centigrade. (iii) Power factor of the electronic driver should be at least 0.90 abd efficiency of the luminaire to be more than 85%.
(iv) The fixture should be dark sky complaint. The fixture should use aluminium, MCPCB printed circuit boards for better thermal management. (v) The luminaire should throw the perfect amount of uniform lught with exactly the desired intensity, and best pole spacing, along with better light control. (vi) The luminaire shall employ individual optical lens for the each of the LED's to ensure better uniformity of light distribution. (vii) The fixute should be vibration resistance, if the fixture is also to be used in vibration prone areas like flyovers/ bridges. (viii) Heat dissipation should be managed through a built in external heat sink.
S&F in replacement of 90 Watt street light drivers and testing after fixing driver complete all as specified and as directed.
S&F in replacement of 200 Watt street light drivers and testing after fixing driver complete all as specified and as directed.
S&F in repairs FRLS PVC insulated standed copper conductor wire of 1.5 Sqmm, 2 Core from existing junction box to light fitting complete all as specified and as directed.
S&F in repairs PVC non rigid conduit 20mm dia with fixing accessories from existing junction box to light fitting complete all as specified and as directed.
S&F in replacement MCCB of 315-400 Amps, 4 pole, 25 KA with Adjustable thermal setting suitable for 415 Volt, 50 Hz, in existing panel with suitable size lugs, nuts, bolts and washer etc. complete all as specified and as directed.
S&F in replacement MCCB of 200-250 Amps, 4 pole, 25 KA with Adjuestable thermal setting suitable for 415 Volt, 50 Hz, in existing panel with suitable size lugs, nuts, bolts and washer etc. complete all as specified and as directed.
S&F in replacement MCCB of 120-160 Amps, 3 pole, 25 KA with Adjustable thermal setting suitable for 415 Volt, 50 Hz, in existing panel with suitable size lugs, nuts, bolts and washer etc. complete all as specified and as directed.
Disconnecting existing over heated or burnt cable terminal at existing panel/ junction box and cutting out over heated/ burnt portion of cable, stretching/ opening cable to suitable required length from available rings and reconnecting cable in position properly with providing new lugs, tapes etc. for cable size upto 95 Sqmm complete all as specified and as directed.
M&L for preparation of old painted surface of electrical panel inner and outer surface complete of size length (0.5 to 1 m), Height (1 m to 2 m) and Breadth (upto 0.5 m) by scrubbing with iron brush and applying two coats of synthetic enamal paint with spray machine complete all as specified and as directed.
M&L for preparation of old painted surface of electrical panel inner and outer surface complete of size length (1 m to 2 m), Height (1 m to 2 m) and Breadth (upto 0.5 m) by scrubbing with iron brush and applying two coats of synthetic enamal paint with spray machine complete all as specified and as directed.
Replacement of existing unserviceable/ damaged part/ portion of the existing feeder pillar box/ panel boards with supplying and fixing new part or portion fabricated out of 3mm thick MS sheet in position including making necessary adjustments and alignments to make the existing feeder pillar box/ panel board body to required shape(s) and size(s) all as directed by Engineer-in-Charge. Note:- (i) The panel board repaired shall be made totally enclosed, weather proof for MCCB and cable etc. (ii) The rates quoted by the contractor are deemed to be with and including necessary cutting, welding, grinding and jointing etc. as directed to match and accommodate with the existing feeder pillar box/ panel board. (iii) The replaced portion shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer.
S&F in replacement of old u/s LT panel sliding door lock chromium plated or as per existing sample complete all as specified and as directed.
Comprehensive maintenance/ servicing of existing RMU's SF 6, 3 phase, 11 KV, 630/ 400 Amps by authorised dealer only. The scope of work includes:- (a) Calibration of metering system, checking, setting, adjustment of over current relay, earth fault and tripping relay complete all as specified and directed by Engr-in-Charge. The contractor should immediately approach mechanic of authorised dealer as soon as fault occurs/ resetting required. (b) Checking of all incoming and outgoing HT Terminals for any looseness and ensuring the proper tightness for all terminals. (c) Checking the nominsl operating gas presssure as per manufactures standard of RMU and testing for any leakage of insulation gas and rectify the same if found. (d) Operating gas pressure should be suitable to satisfy the rated dielectric strength. (e) Testing for CT's, PT's, relays, breakers and cable glands. (f) Anti oxide greasing should be done at all connections of cable and bus bars.
Note:- (i) The contractor should ensure the proper functioning of RMU's and should approach with authorised dealer for carrying of servicing of breaker periodically and when fault/ breakdown occurs. (ii) Contractor shall produce all purchase voucher and test certificate before submitting the RAR. (iii) The contractor will be responsible for serviceability of RMU's for the entire contract period (iv) Unserviceable Spare Part will be paid and measured separately under respective items of schedule.
Servicing of transformer upto 500 KVA/ 250 KVA at carrying out insulation resistant test (HT-LT,HT-E & LT-E), BDV of Oil (top & bottom sample), filtration & topping up of oil, test, quaterly resistance check of earth pits, arresting of leakage by proper tightening of terminals and joints, replacement of loose or burnt out gasket and proper sealing of valves etc as directed by Engineer-in-Charge. Notes:- (i)The cost involved for oil filtration and topping with new mineral oil will be measured and paid separately. (ii) The contractor should produce all testing certificates immediately after testing. Moreover testing should be carried out by authorized OEM only. (iii) The contracted labour manning the substation should immediately inform any oil leakage, change in colour of silica gel, level down of oil in conservator etc.
Dehydration/ filtration of transformer oil of transformers, of various capacities installed in different locations under GE (AF) Chiloda, by recirculation existing transformer oil with trolley mounted filtration plant till dielectric strength is up to 40 KV to 50 KV. Note:- Quoted rates shall be deem to include for following:- (i) Contractor shall be submite the recorded test results before and after filtration of oil. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete. (iii) The contractor solely responsible for any damage to the transformer during filtration operations. He is responsible for making good any damage to the transformer at his own cost without any extra cost to the department. (iv) The contractor shall ensure that the conservator tanks are full to its level before starting the dehydration.
Supply, filling and topping up the transformer/ voltage stabilizer with dielectric strength 50 KV new transformer oil duly filtered with filtration plant complete all as specified and as directed. Note:- (a) The transformer oil shall be type EHV confirming to IS : 3357 of 1983.
Replacement of old u/s rubber mat with the new rubber mat suitable for LT panel of size 2mx1mx15mm thick, ISI marked complete all as specified and directed by Engr-in-Charge.
S&F in replacement worn out HT terminal with bush of existing size for transfomers upto 500 KVA capacity to arrest leakage by opening top cover and refixing the same with replacement of worn out gasket complete all as specified and as directed.
S&F in replacement worn out LT terminal with bush of existing size for transfomers upto 500 KVA capacity to arrest leackage by opening top cover and refixing the same with replacement of worn out gasket complete all as specified and as directed.
S&F in replacement transformer breather silca jel complete all as specified and as directed.
M&L for isolating the HT supply of transformer, disconnecting HT and LT connecting of transformer and isolating the cables from transformer indoor/outdoor of 250 KVA to 500 KVA capacities checking of transformer diaphragm oil condition and carrying out necessary tests for finding fault such as megger test, ratio test, magnetic balance test. short circuit test including opening the lid after draining out oil as required to check the lead connection from winding to bus rods including necessary soldering/ jointing etc and after repair charging of transformer and testing complete all as specified and as directed.
M&L for preparation of old painted surfaces of floor mounted transformer of 250 to 500 KVA capacity by cleaning/ rubbing with course cloth wire brushes to remove dust deposits oil grease and painting with two coats of synthetic enamel paint complete including writing the SM No./ MES No. on transformers with white paint in the existing style/ pattern complete all as specified and as directed.
Comprehensive maintenance and servicing of DG sets of capacity 75/ 200 KVA of any make with general maintenance work such as adjustment of fan belt, valve clearance, hose pipe, battery terminal etc. replacement of defective/ worn out parts by new spares such as filters, engine oil, coolent, etc. including cleaning, greassing and testing after repair complete all as specified and as directed. Note:- (i) Defective major components/ spares if required shall be measured as Supply only under respective items here-in-after and labour element included in this item for replacement. (ii) All the repair carried out at the concern installation or if required in worksshop and spare parts as under will be replaced as required as per cat part or as per existing sample to shoot the equipment for smooth functioning.
All as per Item No. 232 above but for DG set of 10 to 20 KVA capacity.
Supply only fuel filter (Primary and baby) element with O rings for 75/ 200 KVA capacity DG set complete all as specified and as directed.
Supply only fuel filter element with O rings for 10/ 20 KVA capacity DG set complete all as specified and as directed.
Supply only engine oil filter with O rings for 75/ 200 KVA capacity DG set complete all as specified and as directed.
Supply only engine oil filter with O rings for 10/ 20 KVA capacity DG set complete all as specified and as directed.
Supply only air filter element for 75/ 200 KVA capacity DG set complete all as specified and as directed.
Supply and filling in sump/ toping up multi grade engine oil complete all as specified and as directed.
Supply and filling coolent in DG set radiator complete all as specified and as directed.
Supply and filling electrolite of specific gravity in lead acid batteries of DG set complete all as specified and as directed.
Supply and replacement of old u/s door lock for canopy type DG set complete all as specified and as directed.
Supply and replacement of old u/s fan belt suitable for 75 to 200 KVA capacity DG set (as per existing sample) complete all as specified and as directed.
Supply and replacement of old u/s radiator ruber hose pipe with clamp suitable for 75 to 250 KVA capacity DG set (as per existing sample) complete all as specified and as directed.
Supply and replacement old unsv battery brass terminal (as per existing sample) complete all as specified and as directed.
Supply and replacement old unsv DG set battery lead PVC insulated multi stranded copper conductor (as per existing sample) complete all as specified and as directed.
M&L for disconnecting of radiator from 75 to 200 KVA DG set and transporting to authorized workshop to carry out repair i.e. cleaning descaling with restore plus solution, removal of leakage, welding brazing and re-fixing it at site and testing after repair complete all as specified and as directed.
M&L for repairing and overhauling of 12/ 24 Volts self starter including replacement of fly wheel ring carbon bushes,bearing bushes, re-winding of armature and filled and warnishing complete all as specified and as directed.
Supply and replacement old unsv AMF panel battery charger of DG set as per existing sample complete all as specified and as directed.
M&L for disconnecting unserviceable fuel injection pump of any type from DG set with disconecting of fuel injector pipe and transporting to authorised work shop for necessary repairing and after repair calibration the fuel injection pump till the required results and fixing the same after repair complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of battery 12 Volt, 180 AH, 2 year warranty complete all as specified and as directed.
M&L for servicing of servo controlled voltage stabilizer 200 KVA, 415 Volt including setting of Input and output voltage complete all as specified and as directed. Note:- Spare required for replacement if any will be measured and paid separately.
Supply and replacement old u/s shunt trip coil of any size as per sample.
Supply and replacement old u/s control PCB as per sample.
Repairs/ maintenance of APFC panel of capacity 50 KVAR to 250 KVAR including replacement of burned cable with lugs, insulator, MCB etc. calibration of relay, digital meter including testing complete all as specified and as directed. Note:- Unserviceable spare part will be paid and measured separately under respective items.
S&F in repairs 25 KVAR capacitor duty contactor, 240 Volts, AC coil complete all as specified and as directed by Engr-in-Charge.
S&F in repairs 25 KVAR cylindrical capacitor, 440 Volts, 3 phase, 50 Hz complete all as specified and as directed by Engr-in-Charge.
S&F in replacement digital volt meter 0 to 500 Amp, 3 phase as per existing sample complete all as specified and as directed.
S&F in replacement digital 3 phase Ammeter as per existing sample complete all as specified and as directed.
M&L for replacement of old u/s indication lamps with LED type indication lamps with showing red, yellow and green colours suitable for 240 Volts AC supply as per existing size including connection complete all as specified and as directed.
S&F in replacement LT CT as per existing sample rating complete all as specified and as directed.
S&F in replacement of RMU HT CT 30/ 60 ratio as per existing sample complete all as specified and as directed.
ALBA AC AND REF SERVICES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .