Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 CrAccepted-AOC | ₹3.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.9 Cr+₹17.5 L (4.76%)Rejected-Finance 8 34A FATHIMAPURAM TAMILNADU | TAMILNADU | ₹3.9 Cr+₹17.5 L (4.76%) | L2 | Rejected-Finance L2 |
| 3 | L3₹5.2 Cr+₹1.6 Cr (42.5%)Rejected-Finance 61 3134 1ST FLOOR MATHA ARCADE KSN MENON ROAD VRM ROAD JN RAVIPURAM KOCHI 682016 | KOCHI | ERNAKULAM | KERALA | 682016 | ₹5.2 Cr+₹1.6 Cr (42.5%) | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical 37 1634 IMPERIAL HOUSE KALOOR KATHRIKADAVU KATHRIKADAVU ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | - | - | Rejected-Technical Technically Disqualified |
| 5 | Rejected-Technical | - | - | Rejected-Technical Technically Disqualified |
Tender Value
Refer Docs
EMD Value
₹3.8 L
Closing Date
29 Oct 2020, 6:00 pmClosed
CGM RS and E
Kochi Metro Rail Ltd, 4th Floor, JLN Stadium Metro Station, Kaloor
Electrical Utility Shifting and UG cable conversion as part of construction of road widening of seaport-Airport road From Kakkanad Signal Junction To Infopark expressway entrance
2020_KMRL_389870_1
KMRL/SYS/AM(EM)/2019/198/339
Open Tender
Electrical Works
Item Wise
365 days
Kochi
Please refer Tender documents.
21 documents required · 21 mandatory
₹23,600
Yes
online
₹3.8 L
Yes
Kochi Metro Rail Ltd, 4th Floor, JLN Stadium Metro
2 Jan 2021
6 Oct 2020
2 Nov 2020
6 Oct 2020
29 Oct 2020
19 Oct 2020
6 Oct 2020 - 17 Oct 2020
14 Oct 2020
Electrical Items
Supply of HDPE pipe confirming to PN4 as specified the size given below, laying of HDPE pipe properly and continuously joined and laying as per specification . 110 mm
Supply at the site of work of HT, XLPE insulated armoured, Aluminium conductor cable as per IS7098/part-II/1985 with latest amendment & specification of the sizes given below, laying of cables in HDPE pipes in all areas, all type of soil, ootpath, road, tec.. by excavation with laying arrangement in sand cushion and brick/Tile protection at required depth and refilling, tarring after laying of cables through pipe as required/approved by utility owning agency, Testing and commissioning of cable as required as per standards and directions of officers. 11kV XLPE 3x300sqmm
Supply at the site of work of HT, XLPE insulated, armoured, Aluminium conductor cable as per IS 7098/part-ll /1985 with latest amendment & specified in the specification of the sizes given below, laying of cables in cable duct or cable trench including conveying cable from Sub Regional Store/stacking place to work site and laying it carefully using cable rollers, taking through stoneware/G.I. pipes at road crossing/culverts/bridges etc.. after laying of cables through cable duct as required/approved by utility owning agency , Testing and commissioning of cable et complete as required as per standards and directions of officers. 11Kv XLPE 3x300sqmm
Supply at the site of work of HT, XLPE insulated, armoured, Aluminium conductor cable as per IS 7098/part-ll /1985 with latest amendment & specified in the specification of the sizes given below, laying of cables in all type of soil ,footpath,road ,etc(open trench) by excavation with laying arrangement in sand cushionn and brick/Tile protection at required depth and refilling after laying of cables and testing & commissioning of cable etc complete as required as per standards and directions of officers. 11Kv XLPE 3x300sqmm
Supply at the site of work of LT, XLPE insulated, armoured, Aluminium conductor cable as per IS 7098/part-l /1988 with latest amendment & specified in the specification of the sizes given below, laying of cable in HDPE pipe in all areas, all type of soil ,footpath,road ,etc by excavation with laying arrangement in sand cushionn and brick/Tile protection at required depth and refilling after laying of cables through pipe as required/approved by utility, including supply & doing HS type end termination, testing & commissioning of cable etc complete as required as per standards and directions of officers. 1.1Kv 3.5x185sqmm
Supply at the site of work of LT, XLPE insulated, armoured, Aluminium conductor cable as per IS 7098/part-Il /1985 with latest amendment & specified in the specification of the sizes given below, laying of cables in cable duct or cable trench including conveying cable from Sub Regional Store/stacking place to work site and laying it carefully using cable rollers, taking through stoneware/G.I. pipes at road crossing/culverts/bridges etc. after laying of cables through cable duct as required/approved by utility owing aegncy, testing & commissioning of cable etc complete as required as per standards and directions of officers. 1.1Kv 3.5x185sqmm
Supply at the site of work of LT, XLPE insulated, armoured, Aluminium conductor cable as per IS 7098/part-l /1988 with up to date amendment & specified in the specification of the sizes given below, laying of cables in all type of soil ,Open cable trench,footpath, road ,etc by excavation with laying arrangement in sand cushionn and brick/Tile protection at required depth and refilling after laying of cables as required/approved by utility owning agency, including supply &doing HS type end termination,and testing & commissioning of cable etc complete as per standards and directions of officers. 1.1Kv XLPE 3.5x185sqmm
Supply ,Drawing of 11kv Aerial bunch cable of size 3x150 + 1x120(Insulated messenger)with suitable Anchor clamp/dead clamp,suspension clamp,surge arrestor,TEE/straight through joint,termination joint,cable ties,spiral earthing set,earth connector,fitting cross arms,stainless steel strap and buckle etc suitable for 11kv Aerial bunch cable of size 3x150 + 1x120(Insulated messenger) including cutting and removing tree branches wherever necessary and conveyance of all materials from stacking place.at the site of work and testing & commissioning of Aerial bunch cable etc complete as required as per standards & specified in the specification of the below size 11 kV Ariel bunched cable XLPE insulated of size 3 x 150+ 1 x 120 sqmm with bare/insulated Messenger
Supply ,laying of 1.1kv Aerial bunch cable of size 3x95 + 1x70(Insulated messenger) with suitable Anchor clamp/dead clamp,suspension clamp,surge arrestor,TEE/straight through joint,termination joint,cable ties,spiral earthing set,earth connector,fitting cross arms,stainless steel strap and buckle etc suitable for 1.1kv Aerial bunch cable of size 3x95 + 1x70(Insulated messenger) including cutting and removing tree branches wherever necessary and conveyance of all materials from stacking place.at the site of work of 1.1Kv Aeriel Bunched cable as per IS & specified in the specification of the below size. 1.1 kV Ariel bunched cable XLPE insulated of size 3 x 95(For Phase) + 1 x 70(insulated messenger neutral) + 1x16(street light) sqmm
Supply, Making testing & commissioning of complete Heat shrinkable type indoor/ outdoor type and end termination as specified in the specification including provision of laying,dressing, Tagging,Glanding with Lugs/ferrules for termination of 11kv HT XLPE insulated cable including making holes in the switch board, clamping supporting complete as required by utility owning agency following sizes and as per standards and directions of officers. Additional loop of cable should be made before end termination on the structure/Ground as per direction of officer 11kv H.S type 3x300sqmm
Supply, Making testing & commissioning of complete Heat shrinkable outdoor type and straight through Joint as specified in the specification including provision of Lugs/ferrules for joining the HT/LT, XLPE/PILCA/PVC Insulated cables, excavation of pits and cushioning protective covering refilling of jointing pit etc as required by utility owing agency of following sizes and as per standards and directions of officer. 11kv H.S type 3x300 sqmm
Supply and erection testing and commissioning of DA compactible outdoor Extensible type ring main unit, CCT type with AFLR protection for replacing tapping DP structure of 11kv HT circuits and on RCC 1:2:4 foundations using foundation bolts and including cost of 11KV HT cable end termination etc complete including cost of all materials and labor, as per standards and directions of officers.(Annexure II is enclosed)
Supply and erection testing and commissioning of DA compactible outdoor Extensible type ring main unit, CCC type with AFLR protection for replacing tapping DP structure of 11kv HT circuits and on RCC 1:2:4 foundations using foundation bolts and including cost of 11KV HT cable end termination etc complete including cost of all materials and labor, as per standards and directions of officers.(Annexure-III is enclosed)
Supply and erection testing and commissioning of DA compactible outdoor Extensible type ring main unit, CCCT type with AFLR protection for replacing tapping DP structure of 11kv HT circuits and on RCC 1:2:4 foundations using foundation bolts and including cost of 11KV HT cable end termination etc complete including cost of all materials and labor, as per standards and directions of officers.(Annexure-II is enclosed)
Supply and erection testing and commissioning of DA compactible outdoor Extensible type ring main unit, CCCC type with AFLR protection for replacing tapping DP structure of 11kv HT circuits and on RCC 1:2:4 foundations using foundation bolts and including cost of 11KV HT cable end termination etc complete including cost of all materials and labor, as per standards and directions of officers.(Annexure-III is enclosed)
Supply and erection testing and commissioning of DA compactible outdoor Extensible type ring main unit, CCCTT type with AFLR protection for replacing tapping DP structure of 11kv HT circuits and on RCC 1:2:4 foundations using foundation bolts and including cost of 11KV HT cable end termination etc complete including cost of all materials and labor, as per standards and directions of officers.(Annexure-II is enclosed)
Supply and erection testing and commissioning of DA compactible outdoor Extensible type ring main unit, ADD ON Module RMU - Type - +C+ consists of 1nos Load Break switches with complete coupling accessories for replacing tapping DP structure of 11kv HT circuits and on RCC 1:2:4 foundations using foundation bolts and including cost of 11KV HT cable end termination, Earthing, coupling with existing RMU etc complete including cost of all materials and labor, as per standards and directions of officers.
Supply and erection testing and commissioning of DA compactible outdoor Extensible type ring main unit, ADD ON Module RMU - Type - +V+ consists of 1nos Vaccum circuit breaker with complete coupling accessories for replacing tapping DP structure of 11kv HT circuits and on RCC 1:2:4 foundations using foundation bolts and including cost of 11KV HT cable end termination, Earthing, coupling with existing RMU etc complete including cost of all materials and labor, as per standards and directions of officers.
Fitting including supply of material one Fuse unit (one no.) and giving connection from Transformer to fuse units and fuse units to LT OH line
Dismantling (taking out from ground) if necessary all sizes of XLPE cable/Pilca/ Pvc cables, without damaging the cable. By excavation in all types of area (all type of soil) with refilling excavated Trenches as per standards and directions of officers. This also includes handling over of dismantled cable (if not relayed) to concerned utility agency.(including Transportation)
Dismantling (taking out from tarred road and concrete surface) if necessary all sizes of XLPE cable/Pilca/ Pvc cables, without damaging the cable. By excavation in all types of area with refilling excavated Trenches as per standards and directions of officers. This also includes handling over of dismantled cable (if not relayed) to concerned utility agency.(including Transportation)
Dismantling (without damage) LT 3phase 4/5 wire OH line including existing stucture ,stay, strut,cross arms,insulators.. etc...and transportation and stacking of all materials at suitable locations as per instructions including digging out loading and unloading on to lorries without damaging the materials. This also includes handling over of materials to concerned utility agency.(including transportation)
Dismantling (without damage) HT lines(3 conductor) including existing stucture ,stay,strut,cross arms,insulators, etc...and transportation and stacking of all materials at suitable locations as per instructions including digging out loading and unloading on to lorries without damaging the materials.This also includes handling over of materials to concerned utility agency.(including transportation)
Dismantling and shifting of RMU at various locations and re- erecting, including foundation works ,Providing end termination ,looping of cable etc and earthing complete as required as per standards and directions of officers.
Dismantling existing Transformer,transformer Structure posts, etc of Transformer installation and transportation and stacking of all materials at suitable laocation as per instruction of officer including digging out loading and unloading on to lorries, etc of poles Transformers, and materials without damaging the same.Erecting the transformer on the new constructed plinth/DP structure and giving connections,fittings etc complete as per standards and directions of officers excluding cost of plinth.
Dismantling existing DP Structuress using A-pole /PSC pole as per instruction including digging out of poles , and materials without damaging the same including digging out,loading and unloadind and staking in suitable locationThis also includes handling over of materials to concerned utility agency.(including transportation).
Dismantling existing DP Structuress using A-pole /PSC pole as per instruction including digging out of poles , and materials without damage and rererecting the DP structure with the same materials at near by location as instructed by the officer .
Dismantling one LT PSC/RCC/RS Joists/TW pole,fittins,service connections etc including digging and back filling pit .This also includes handling over of materials (if not relayed) to concerned utility agency.(including Transportation)
Dismantling one 11 kv A- pole/HT PSC/RCC/TW including accessories,fittings etc and This also includes handling over of dismantled cable (if not relayed) to concerned utility agency.(including Transportation)
Supply and erection at site LT/RSJ/PSC/RCC poles at site of required height including foundation(concrete muffing as per IS 5613(Part1/sec2)) digging and back filling with fittings including x-Arms and clamps / insulator,stay and including all materials cable loop In-loop-out as per standard and direction of officers
Supply and erection at site HT/RSJ/PSC/RCC poles at site of required height including foundation (concrete muffing as per IS 5613(Part1/sec2)) digging and back filling with fittings including x-Arms and clamps / insulator,stay and including all materials cable loop In-loop-out as per standard and direction of officers.(Annexure-IV is enclosed)
Supply and erection one A-pole (painted MS) at site of required Height including foundation and concrete muffing as per standard and fittings , crossarms ,insulator,cable looping ,diggingand back filling pit,stay,earth leads including all materials as per standards and direction of officers.(Annexure-V is enclosed)
Supply and erection one DP/Transformer structure using A-pole (painted MS) at site of required Height including foundation and AB switch,lightning arrestor, fittings , crossarms ,insulator,cable looping ,digging and back filling pit,earth leads and earthing including all materials as per standards and direction of officers.
Providing Strut using LT pole including digging and back filling pit(Taken from dismantled items)
Providing earthing for poles and support, pillar boxes panels, structures, Transformers,RMU's etc including supply of materials, Excavation, giving connection, laying lead wire, etc complete using 40mm Gi pipes 3mt long and Gi wires of size up to No.6 SWG.
Constructing Transformer plinth foundation(Cement concrete column)inclusive of cost of all materials as per standard and direction of officers.(Annexure-I is enclosed)
Dismantling and reconnecting Single phase service connection required from the OH line incl..lower down the WP portion
Dismantling and reconnecting 3 phase service connection required from the OH line incl..lower down the WP portion
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .