| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC 708 PREM NAGAR KARNAL HARYANA 132001 | KARNAL | KARNAL | HARYANA | 132001 | L1 | Accepted-AOC LOA | |
| 2 | L2₹44.5 L+₹1.2 L (2.66%)Rejected-Finance AMAR NIWAS RA 288 GANDHI CHOWK SADAR BAZAR KARNAL | KARNAL | KARNAL | HARYANA | L2 | Rejected-Finance Highest | |
| 3 | L3₹45.8 L+₹2.4 L (5.53%)Rejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L3 | Rejected-Finance Highest | |
| 4 | L4₹48.0 L+₹4.6 L (10.7%)Rejected-Finance 00 LALPUR KICHHA ROAD RUDRAPUR KICHHA RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263148 | UDAM SINGH NAGAR | UTTARAKHAND | 263148 | L4 | Rejected-Finance Highest |
Tender Value
₹52.7 L
EMD Value
₹1.1 L
Closing Date
23 Jan 2024, 5:00 pmClosed
NAVEEN RATHEE
ED - Ambala
Establishment of Civil Enclave at Ambala for Commencement of Flight Operations Under Rcs Udan Scheme in Ambala District (Pdg. Sub Station and DG Set)
2024_HRY_343030_1
2024F531C8C3 95A1 49D6 BD19 34A54B0EBF30663BAR
Open Tender
Civil Works
Works
280 days
Ambala Cantt
Establishment of Civil Enclave at Ambala for Commencement of Flight Operations Under Rcs Udan Scheme in Ambala District (Pdg. Sub Station and DG Set)
2 documents required · 2 mandatory
₹5,000
₹1.1 L
Yes
14 Mar 2024
10 Jan 2024
24 Jan 2024
10 Jan 2024
23 Jan 2024
10 Jan 2024
Amount
[23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA
[23.22.1.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.4. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA
[23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA
[23.22.2.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.3. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB above 250 A and up to 630 A FP
[23.22.8.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.4. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 300 amp 415 volts
[23.24.1]MS STAND, BUS BAR CHAMBER AND PANELS 1. Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide.
[23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages.
[23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages.
[23.26.3]SAFETY ITEMS 3. Supply and erection of shock restoration chart in glass frame.
[23.26.4]SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia).
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.11]EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
[24.10.1]CIVIL ITEMS (USED COMMONLY IN ELECTRICAL WORKS) 1. Digging & refilling of trench 30 cm wide below ground level for erection of pipe/cable (up depth of 1 Metre. underground cable excluding the cost of cable/pipe complete in all respect.
[24.10.2]CIVIL ITEMS (USED COMMONLY IN ELECTRICAL WORKS) 2. Earth work in excavation in foundations, trenches etc. in all kind of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches, staking the excavated soil clear from the edge of excavation and subsequent filling around masonry, in 15cm layers with compaction, including disposal of all surplus soil, as directed with in a lead of 30 metres.
[24.10.4]CIVIL ITEMS (USED COMMONLY IN ELECTRICAL WORKS) 4. cement concrete 1:2:4 with stone aggregate 20 mm nominal size in Kerbs and the like items, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including from work, placing and fixing in position, complete at the ground level or in first storey
[24.2.10]LT CABLE 10. Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S. Rod welded/riveted at the top with 10 cm dia 3 mm thick MS plate inscribed with cable word on it, having a cross arm 30 cm long of the same dia welded at the bottom, in exiting trench 45 cm below ground level.
[24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core
[24.2.7.4]LT CABLE 7.4. Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core
[24.2.7.5]LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core
[24.2.7.6]LT CABLE 7.6. Supply and erection of suitable compression type brass cable glands for underground Cable :- 240 sqmm to Cable 3 to 32 Core
[24.2.8.10]LT CABLE 8.10. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 120 sqmm
[24.2.8.12]LT CABLE 8.12. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 185 sqmm
[24.2.8.9]LT CABLE 8.9. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 95 sqmm
[24.3.3.1]HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm
[24.3.4.1]HT CABLE 4.1. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia
[24.5.2.6]MISCELLANEOUS ITEMS 2.6. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 145/123 mm outer dia/ inner dia
Supply and Erection of 95 Sq. mm 3.5 Core Cable Armoured under ground cable ,loose in existing pipe or trenches, complete with necessary connections including all required material to complete the job in all respect up to the entire satisfaction of the Engineer in charge of the work. Make Havells/Polycab/RR.
Supply and Erection of 120 Sq. mm 3.5 Core Cable Armoured under ground cable ,loose in existing pipe or trenches, complete with necessary connections including all required material to complete the job in all respect up to the entire satisfaction of the Engineer in charge of the work. Make Havells/Polycab/RR.
Supply and erection of MS Channel 100x 50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. (As per UHBVNL make and specification).
Supply and erection of MS angle 50x 50 x 6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. (As per UHBVNL make and specification)
Supply and erection of MS flat 50 x 6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. (As per UHBVNL make and specification)
Providing. and fixing of Nut and Bolts of size as per ISI specifications of Engineer-in-charge. (As per UHBVNL make and specification)
Supply and Erection of 185 Sq. mm 3.5 Core Cable Armored under ground cable ,loose in existing pipe or trenches, complete with necessary connections including all required material to complete the job in all respect up to the entire satisfaction of the Engineer in charge of the work. Make Havells/Polycab/RR.
Supply and Erection of rubber mat of size 1M x 2 M X 6mm thick suitable for 11 KV ISI marked complete in all respect upto the entire satisfaction of the engineer In-charge of the work.
Pdg. and Fixing of wire mesh jali around the transfarmer of size 4` x 8` made out of 75 x 25 x 3.25 mm jali fixed with angel iron frame made out of M.S. Angel 50 x 50 x 6 mm complete in all respect upto entire satisfaction of engineer in charge of work.
Supply and erection of prestressed cement concrete pole as per IS : 1678-1960. 11 metres long 152 mm x 203 mm at top and 152 mm x 368 mm at bottom with working load of 360 Kg. burried 2.20 m in ground complete in all respect upto entire satisfaction of engineer in charge of work.
Supply and Erection of G.S.L wire 7/8 SWG conforming to ISS 280/1975/1963 with latest amendment complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work
Supply and erection of lighting arrestor model ALPRO / Alastem / LEMCO make suitable for 11KV 3 Phase 50 HZ ground neutral system comprising of spare gape type queen gap type in series with non linger resitar element house in Horizontally scale poreclam bushing with line and ground terminal along with mounting clamps conforming to ISS 3070 (Part-I) of 1985 with latest amendment with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works
Providing and Fixing of Stay Set complete in all respect upto the entire satisfaction of Engineer-in-Charge of work.
Providing and Fixing of stay wire complete in all respect upto the entire satisfaction of Engineer-in-Charge of work.
Supply and erection of 11KV pin insulator (Jayshree make) with pin with all labor and material required to the complete the job included the fixing the same on existing channels up to entire satisfaction of the Engineer-in-Charge of the work..
Supply and Erection of 11KV gang operated switch Jayshree make conforming to IS with latest amendment including suitable size of copper blade erection of same on the existing `H` pole with the help of 3 Nos. channels of size 75mm x 40mm x 6mm, 1.8M long fixed with suitable size of MS clamp, nuts and bolts including cost of 6 Nos. 11KV insulator with GI pin, RD fuses and painting with 2 coat of approved paint and one coat of red oxide material required to complete the job in all respect up to entire satisfaction of the Engineer-in-Charge of the work.
Supply and Erections of Three phase 4 wire LT CT operated (inbuilt CTs) Static Energy meters (40-200 Amps) of class 1.0 accuracy (DLMS complaint consumer meter) with GSM modem and conforming to Nigam specification and latest amendments thereof. complete in all respect upto entire satisfaction of engineer in charge of work.
Supply and erections of 11 KV protection CT and PT with latest amendments complete in all respect upto the entire satisfaction of Engineer-in charge of work.
Supply and Erection of fire buckets of 9 liter. capacity made out of 24guage G.l sheet and duly painted with one coat of red oxide and 2 coats of approved paint in red colour and written with the fire` as per fire protection necessar sand filling in the bucket hung the bucket on stand with all labour and material required to complete the job all respect up to entire \satisfaction of the Engineer m charge of the work.
Supply and erection of G.I pipe 65 mm dia surface, complete with necessary connections complete in all respect including all material required to complete the job in all respect and up to the Entire satisfaction of the Engineer in charge of the work.
Supply , Erection , testing and commissioning of 11 KV outdoor type HT Metering panel complete with CTs , PTs cubical and electronics Meter with accuracy class 0.5 as per requirement / approved by UHBVN. Panchkula Electrical Supply consisting of following : i)Cubical panel free standing floor mounting type made of sheet steel 14 G SWG CRCA sheet with channel iron base frame spray painted with strong synthetic grey channel paint as per size and design approved by UHBVN. complete in all respect including all material required to complete the job in all respect and up to the entire satisfaction of the Engineer in charge of the work .
Supply ,installation, Testing and Commissioning of wall / free standing floor mounting dust and vermin proof compartmentalized Cubical Panel made out of 2mm thick CRCA sheet steel required hardware 3mm thick Bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of zinc / red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3 mm thickness, separate detachable gland plate, MS base channel ,hinged door with interlocking arrangement for equipment /switchgear. Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar Bakelite sheet of 3mm thick for separating cable alley to BBC from switch chamber Extended solid copper bus bars upto cable alleys shall be provided for outgoing connections which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure .The panel will be complete with control wiring (copper) and fuse protection. (Only outer area on all sides shall be measured) complete in all respect upto entire satisfaction of engineer in charge of work.
Supplying and fixing of copper bus bar duly tinned by means of SMC /DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with color coding heat shrinkable PVC insulation complete in all respect.
250 KVA Tansfomer Shed size 20x20 fee, Pdg. And fixing M.S tubular frames for doors, windows, ventilators and cupboards with rectangualr/L-Type sections, made of 1.60 mmthick M.S Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hings and screws and applying a priming coat of approved steel primer, Fixing with 15x3 mm lugs 10cm long embedded in cement concrete block 15x10x10 cm of C.C 1:3:6 (1Cement:3 coarse sand:6 graded stone aggregate 20mm nominal size, fixing with carbon steel galvanised dash fastener of required dia ans size to be paid for separately, Pdg, and fixing poly carbonate sheet, 1:25mm thickness on gates and grills excluding the cost of MS framework but i/c the cost of nut bolts, welding rods complete, Reinforced cement concrete work in arches, arch ribs, domes, vaults, shells, folded plate and roofs having slope more than 15 upto floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1:5:3 (1 cement:15 coarse sand (zone-III):3 graded stone aggregate 20mm nominal size, Pdg. and fixing angle iron frames for doors, windows and mitred and welded by angle iron 35x35x5mm, joints mitred and welded by angle iron 35x35x5mm or 35x5 mm flat i/c fixin of neccessary butt hinges and screws and applying a priming coat of approved steel primerr, all complete, Pdg. and fixing hard drawn steel wire faric 75mmx25mm rectangular mesh with 3mm thick flat iron cover moulding of 12.5mm width fixed with machine screws welded complete, Painting steel work with deluxe multi surface, paint to give an even shade. two or more coat applied 0.90 litre/10sqm of approved brand and manufacture, complete in all respect upto entire satisfaction of engineer in charge of work.
SITC of 160KVA 3 Ph with Water Cooled Silent canopied Generator, Power 160 KVA, Control Panel-AMF/Manual, Controller-Dep Sea, DG Dimensions 3800x1400x2330mm (with silencer), Fuel tank Capacity-420 litres, Weight of DG 2388 Kg., Engine- Frequency-201HP, RPM-1500 RPM, No. of Cylinder/Cylinder arrangment- 6/Vertical Inline, Compression Ratio-17.5:01, Borex Stroke-100x120mm, Displacement-5.7 Litres, Cooling system-Liquid Cooled, Lube Oil system capacity-23.8 Litres, Governer Class/Type-A1/Electronic, Starting system-12V DC Electrical, Coolant Capacity-21.5 Litres, Alternator-Phase-3Phase, Voltage-415V Ac, Power Alternator type-Single Bearing, Three Phase, Insulation H,. Air filter choke, Under frequency, over frequency, overloading, complete in all respect including all material required to complete the job in all respect and up to the entire satisfaction of the Engineer in charge of the work. Make: TMTL Eicher/Crompton Greaves/Kirloskar.
Supply and Erection of 240 Sq. mm 3.5 Core Cable Armoured under ground cable ,loose in existing pipe or trenches, complete with necessary connections including all required material to complete the job in all respect up to the entire satisfaction of the Engineer in charge of the work. Make Havells/Polycab/RR.
Supply and Erection of 50 Sq. mm 3 Core HT XLPE Cable 6.6 kV (UE) 11 kV( E), loose in existing pipe or trenches, complete with necessary connections including all required material to complete the job in all respect up to the entire satisfaction of the Engineer in charge of the work. Make Havells/Polycab/ KEI.
SITC of Providing CO2 Gas portable fire extinguishers (CO2 4.5 KG Fire Extinguisher) conforming to IS: 15683-2006 consisting of seamless MS cylindrical body sqeeze lever discharge valve, internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle ISI marked including fixing with dash fasteners etc. complete. (For Floors, Fan rooms and Electric rooms) Make Safex/Newage/Minimax/ Ceasefire
SITC of Fire Extinguisher Abc 6 Kgs complete the job in all respect and up to the entire satisfaction of the Engineer in charge of the work. Make Safex/Newage/Minimax/ Ceasefire
SITC of 250 KVA, 11/0.433 KV 3 Phase, Oil Cooled Power type tranformer, high voltage-11 KV, Low voltage-0.433 KV, winding mateial- copper, connection (HV/LV)- Delta/Star, Vector Group- Dyn11, Frequency- 50 Hz, tapping on HV Winding for HV Variation- plus 5% to -10% in teps of 2.50% each, Type of Tamp Changer- OFF Circuit tap Changer, Steps/Positions of tap changer- 6 Steps/ 7 Positions, Temprature Rises (Above amnient 50 degree C) - 40 Degree C, Average winding- 45 degree C, Termination = a High Voltage side- Cable Box, b Low voltage side - Cable box, Orientation- 180 degree C, type of colling- ONAN, Duty/Location- Outdoor, Altitude above sea level- Up to 1000 M, Losses on 50% Load- 980 watt (Max), Losses on 100% Load- 2930 watt (Max), Impendance at 75 degree C- 4.50% (IS ToI), Insulation level a. HV-7528 KVp/KVrms, LV -/3 (KVp/Kvrms, 1 no. rating and digaram plate-anodized aluminium, 2 nos, earthing terminals, 4 nos, lifting lugs, 1 no oil level indicator with minimum level marking, 2 nos, thermometer pockets, 1 no. conservator (without air bag type) with oil filling hole with cap and drain plug, 1 no. air release plug, 2 nos, Silica Gel breather, 4 nos. Bi-Directional rollers, 4 nos. jacking pads, radiators with lifting lugs, first filling of oil, Epoxy paint with Shade631 if IS:5, explosion vent with Diaphragm, bottom drain cum filter valve, 2 nos. inspection cover, top filter valve, off load tap changer (OCTC), Buchholz relay with Alarm and trip, oil temperature indicator with Alarm and trip contact (2A), winding tempreture indicator with alarm and trip contact (2A), marshalling box, complete in all respect upto the entire satisfaction of the engineer In-charge of the work. Make Voltamps/ Kirloskar/Crompton/Alstom/ABB/Siemens/Schneider.
Som Nath Contractor
M/s JSB Enterprises
S R Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .