Deputy Municipal Commissioner (D)
CONSTRUCTION OF READING ROOM & HEALTH CLUB AT MOJE: VALAK, NEW BLOCK/ R.S NO. 69 (OLD BLOCK NO.62) AMINITIES SPACE IN NEW EAST ZONE (SARTHANA), SURAT
268622
DMC/NEZ/26/2025-2026, Work No. 02
Open
Civil Works - Buildings
Surat
3 documents required · 3 mandatory
₹14,160
Commissioner, Surat Municipal Corporation
₹6.2 L
22 Jan 2026
22 Jan 2026
22 Jan 2026
16 Feb 2026
22 Jan 2026
Excavation for foundation including sorting out and stacking off
useful materials and disposing of the excavated stuff up to 50 mt.
lead and all lift, watering etc.comp. (A) loose or soft soil
Executed With Mechanised Efforts / Machinaries
(1) Up to 1.5 mt. Depth 1120.00 C.M. 117.26
SMC SOR-PAGE NO 1 IT NO
Boring holes 3.5 mt.deep in ordinary soil ( for cast in situ piles) &
2 disposal of the surplus excavated soil as directed within a lead of
50 M. For following diameter of piles.
250mm dia 50.00 Rmt 326.84
SMC SOR , ITEM NO. 94, PG. NO.
Providing & Filling Rubbles including hand packing & filling
interstics with Quarry Spalls complete for all leads and lifts.
SMC SOR , ITEM NO. 22, PG. NO. 3 114.00 C.M. 1064.80
Providing & laying C.C 1:3:6 (1cement : 3 coarse sand : 6 Crushed
4 stone agg 20m.m Nominal size) &curing comp. excl. cost of form
work in :(a) foundation & Plinth
(A) Foundation 70.00 C.M. 3005.76
(C) Grade Slab 6.00 C.M. 3005.76
SMC SOR, PAGE NO 1 IT NO
Providing & laying cement concrete 1:2:4 (1 cement : 2 sand :
graded stone agg. 20 mm nominal size) & curing comp. Includ. cost
5 of form work but exclu. Cost of reinforcement for reinforced
concrete work in : (A) Foundation, footing, Base of columns and
(C) Grade slab 59.00 C.M. 3637.34
(SOR SMC Pg No. 9 It No. 95)
Providing, mixing, placing, compacting by machine vibrator, curing,
testing M25 Design mix concrete as per IS 456:2000 (latest
revision) and as per tender specification in all items including cost
of form work and rendering but excluding cost of reinforcement
(A) foundation, footing, base of columns and mass concrete 162.00 C.M. 4180.62
(SOR SMC - MIX DESIGN PG. NO-14)
Providing, mixing, placing, compacting by machine vibrator, curing,
testing M25 Design mix concrete as per IS 456:2000 (latest
7 revision) and as per tender specification in all items including cost
of form work and rendering but excluding cost of reinforcement
(1) Having cross sectional area up to 0.085sq.mt. 0.00 C.M. 12587.74
(2) Having cross sectional area more than 0.085 sq. mt .up to
(3) Having cross sectional area more than 0.12 sq. mt. 22.00 C.M. 9190.79
(SOR SMC - MIX DESIGN PG. NO-14)
(1) Having cross sectional area upto 0.08 sq.mt. 0.00 C.M. 8994.86
(2) Having cros sectional area more than 0.08 sq. mt and upto
(3) Having cross sectional area more than 0.12 sq. mt . 46.00 C.M. 6999.09
(SOR SMC - MIX DESIGN PG. NO-14)
DESCRIPTION Qty. UNIT AMOUNT
(1) Slabs having more than 8 Cm & upto 10 Cm thickness. 0.00 C.M. 7887.74
(2) Slabs having more than 10 Cm & upto 13 Cm
(3) Slabs having more than 13 Cm thickness. 4.00 C.M. 6727.93
(SOR SMC - MIX DESIGN PG. NO-14)
(E) RCC Wall - 200 mm Thick 13.00 C.M. 7946.64
(SOR SMC - MIX DESIGN PG. NO-14)
Providing & fixing IS Mark TMT Bar FE 500d reinforcement for
8 R.C.C. work incl. bending, binding & placing in position etc.comp.---
Upto G.L./P.L. 31590.00 Kg. 76.21
(SOR SMC Pg No. 1 It No. 8)
Providing & construction brick work using Fly Ash bricks having
crushing strength not less than 35 Kg./sq.cm. in foundation &
plinth in C.M. 1:6 (1 cement:6 sand ) etc. comp. - Ground Floor
(SOR SMC Pg No. 1 It No. 9) 102.00 C.M. 4237.00
Filling available excavated earth (excluding rock) in trenches.
plinth, sides of foundations etc. in layers not exceeding 20 cm. in
depth consolidating each
disposited layer by ramming and watering.
(SOR SMC Pg No. 1 It No. 10) 1745.00 C.M. 130.39
Filling in foundation and plinth with murrum or selected soil in
11 layers of 20cm. thickness including watering, ramming and
consolidating etc. complete.
(SOR SMC Pg No. 1 It No. 11) 476.00 C.M. 289.06
Providing & Applying 15mm.th.cement plaster in single coat on
brick/ concrete walls similar surfaces for plastering & finished
12 even & smooth with a floating coat of cement slurry mixed with
admixture of lime or neeru in required proportion etc. comp. in C.M
1:3 (1 cement : 3sand)
(A) for wall and similar surfaces
Upto G.L./P.L. 70.00 S.M 237.51
(SOR SMC Pg No. 3 It No. 25)
Providing & Applying 10mm.th.cement plaster in single coat on
brick/ concrete walls similar surfaces for plastering & finished
13 even & smooth with a floating coat of cement slurry mixed with
admixture of lime or neeru in required proportion etc. comp. in
C.M 1:3 (1 cement : 3sand)
(B) for ceilings and soffits of stairs
Upto G.L./P.L. 23.00 S.M 214.60
(SOR SMC Pg No. 3 It No. 24)
NOTE :- (1) The whole work is to be executed through specialized
agency with a guarantee of 10 (Ten) years given on a prescribed
14 proforma duly stamped (2) The rate shall include for work at all 176.00 S.M
floors & conducting water proof test as directed. (M.R.)
Proiding & laying water proofing treatment to vertical and
horizontal surfaces like consisting of (a) I course of applying
cement slurry 4.4 kg per sq.mt. mixed with water proofing
compound confirming to IS:2645 in rcommended proportions. (b)
II corse of 20mm cement plaster 1:3 mixed with water proofing
compound in recommended proportion (c) III course of applying
blown or / resideal bitumen applied hot at 1.7 kg per sqm of area.
(d) IV course of 400mm micron th. PVC sheet. (Overlaps at joints of
PVC sheet should be 200mm wide and pasted to each other with
bitumen about 1.7 kg./ sqm.)
(SOR SMC Pg No. 6 It No. 63)
DESCRIPTION Qty. UNIT AMOUNT
carrying out plinth treatment to post construction/existing
structure by spraying chemical solution for termite control
treatment including labour and material consisting with ISI
specification using chlordene and chiorpurfiles 20 EC as per
15 6131_part II concentration weight one litter give 1% concentration 494.00 S.M.
inclusive of one litter chemicals emulsions application at the rate of
5 litter chemicals /sqmt of surface is recommended as per IS.
(SOR SMC Pg No. 12 It No. 127)
Providing 20 mm thick double coat mala cement plaster on
brick / concrete work for plastering comprising of base coat 12 mm
thick cement plaster in cement mortar (1 Cement : 4 coarse sand)
16 in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1
Cement : 2 Coarse sand) finished with trovel including scaffolding
curing etc. complete.
(SOR SMC Pg No. 3 It No. 27) 82.00 S.M 272.48
Providing & applying two coats of weather shield max paint (3
coats may be required in case of darker colours.)of ICI Dulux or
Apex Ultima of Asian Paint including applying exterior acrylic
primer coat as per manufacturers specification and directions in
shade and colour approved by architects, on exterior surfaces of
the building including scaffolding, preparing the surface, watering,
curing etc. complete and as directed by the architects and
Surface Preparation : surface is thoroughly clean, dry and free
from all loose dirt, chalk, grease, fungi,algae and flaking paint. This
can be achieved by brushing with a wire/ stiff coir brush, followed
17 by water jetting if required. Fill up all minor cracks and defects 82.00 S.M
with white cement and sand mixture in the ratio 1:3. For
application on previously painted wall, previous coatings of paint
must be thoroughly scraped off and Clean the surface thoroughly
using wire brushes.
Priming: Apply a liberal coat of exterior acrylic primer and allow it
to dry for 4-5 hours.Application of putty is not recommended.
Minimum 4-6 hours duration is required between each coat of
weather shield max paint
SMC SOR , COLOR WORK ITEM NO.- 17 Page No.
DESCRIPTION Qty. UNIT AMOUNT
WORK ABOVE PLINTH
Providing, mixing, placing, compacting by machine vibrator, curing,
18 testing M25 Design mix concrete as per IS 456:2000 (latest
revision) and as per tender specification in all items including cost
of form work and rendering but excluding cost of reinforcement
(1) Having cross sectional area up to 0.085sq.mt.
Ground Floor 0.00 C.M. 12587.74
First Floor 0.00 C.M. 12627.34
Second Floor 0.00 C.M. 12666.94
Terrace Floor 0.00 C.M. 12706.54
(2) Having cross sectional area more than 0.085 sq. mt .up to
Ground Floor 0.00 C.M. 11136.62
First Floor 0.00 C.M. 11176.22
Second Floor 0.00 C.M. 11215.82
Terrace Floor 0.00 C.M. 11255.42
(3) Having cross sectional area more than 0.12 sq.mt.
Ground Floor 21.00 C.M. 9190.79
First Floor 17.00 C.M. 9230.39
Second Floor 17.00 C.M. 9269.99
Terrace Floor 7.00 C.M. 9309.59
(SOR SMC - MIX DESIGN PG. NO-14)
(1) Having cross sectional area upto 0.08 sq.mt.
Ground Floor 0.00 C.M. 8994.86
First Floor 0.00 C.M. 9034.46
Second Floor 0.00 C.M. 9074.06
Terrace Floor 0.00 C.M. 9113.66
(2) Having cros sectional area more than 0.08 sq. mt and upto
Ground Floor 0.00 C.M. 8075.85
First Floor 0.00 C.M. 8115.45
Second Floor 0.00 C.M. 8155.05
Terrace Floor 0.00 C.M. 8194.65
(3) Having cross sectional area more than 0.12 sq.mt.
Ground Floor 44.00 C.M. 6999.09
First Floor 44.00 C.M. 7038.69
Second Floor 44.00 C.M. 7078.29
Terrace Floor 5.00 C.M. 7117.89
(SOR SMC - MIX DESIGN PG. NO-14)
(1) Slabs having more than 8 Cm & upto 10 Cm thickness.
Ground Floor 0.00 C.M. 7887.74
First Floor 0.00 C.M. 7927.34
Second Floor 0.00 C.M. 7966.94
Terrace Floor 0.00 C.M. 8006.54
(2) Slabs having more than 10 Cm & upto 13 Cm thickness.
Ground Floor 0.00 C.M. 7306.10
First Floor 0.00 C.M. 7345.70
Second Floor 0.00 C.M. 7385.30
Terrace Floor 0.00 C.M. 7424.90
(3) Having more than 13 cm. Thickness
Ground Floor 55.00 C.M. 6727.93
First Floor 55.00 C.M. 6767.53
Second Floor 58.00 C.M. 6807.13
Terrace Floor 14.00 C.M. 6846.73
(SOR SMC - MIX DESIGN PG. NO-14)
Ground Floor 3.00 C.M. 9419.25
First Floor 3.00 C.M. 9458.85
DESCRIPTION Qty. UNIT AMOUNT
Second Floor 2.30 C.M. 9498.45
Terrace Floor 0.30 C.M. 9538.05
(SOR SMC - MIX DESIGN PG. NO-14)
Ground Floor 9.00 C.M. 6913.25
First Floor 9.00 C.M. 6952.85
Second Floor 9.00 C.M. 6992.45
Terrace Floor 1.00 C.M. 7032.05
(SOR SMC - MIX DESIGN PG. NO-14)
Providing & laying C.C 1:3:6 (1cement :3 coarse sand :6 crushed
19 stone agg. 20 m.m Nominal size)& curing comp. incl. cost of from
work in: wall caps/ copings
(SOR SMC Pg No. 9 It No. 97) 17.40 C.M. 3982.62
Providing, mixing, placing, compacting by machine vibrator, curing,
20 testing M25 Design mix concrete as per IS 456:2000 (latest
revision) and as per tender specification in all items including cost
of form work and rendering but excluding cost of reinforcement
(A) Stair cases including landing etc.
Ground Floor 10.00 C.M. 7158.83
First Floor 10.00 C.M. 7198.43
(SOR SMC - MIX DESIGN PG. NO-14)
(B) Vertical and horizontal fins
Ground Floor 0.00 C.M. 9030.72
First Floor 0.00 C.M. 9070.32
Terrace Floor 0.00 C.M. 9109.92
(SOR SMC - MIX DESIGN PG. NO-14)
(C) RCC Wall - 200 mm thick
Ground Floor 5.00 C.M. 7946.64
First Floor 5.00 C.M. 7986.24
Terrace Floor 5.00 C.M. 8025.84
(SOR SMC - MIX DESIGN PG. NO-14)
21 Providing & fixing IS Mark TMT Bar FE 500d reinforcement for
R.C.C. work incl. bending, binding & placing in position etc.comp.---
Ground Floor 21114.00 Kg 76.21
First Floor 20739.00 Kg 77.21
Terrace Floor 20945.00 Kg 78.21
Stair Cabin Top 4490.00 Kg 79.21
(SOR SMC Pg No. 2 It No. 15)
DESCRIPTION Qty. UNIT AMOUNT
Designing, providing and executing Bonded/ Unbonded Post-
tensioning works for slabs/beams/drop panels, etc. Including
decoiling the strands, cutting to the required lengths, supplying and
laying of sheathing (GI corrugated ducts), jointing with couplers
and inserting the strands, profiling, fixing live anchorages suitable
for tendons, grout vents, making dead end anchorages including
lowering the strands, fixing tendon support bars, supervising the
fixing of anti-bursting reinforcement, stressing the cables, end
trimming, grouting the cables with cement and admixtures, with
required plants and machinery tools and tackles, consumables etc.
including co-ordinating with Architectural/Structural consultants
drawings and obtaining approval from client/consultant/Project
Manager for the work done as per the requirement of
Architect/Structural Consultant at site. Also include Area marking
for Post tensioned elements. Area for the same shall be measured
within peripheral RCC beams/walls (Walls/beams not included)
or boundary of the slab etc. including all requisite as per Structural
Engineer instructions.Including all PT memberes (slab & beam)
stagging, shuttering and reproping shall be carried out as per
structural engineer's instruction and suggestion.
(1) All Post Tensioned Beams Detail Shall Only Be Provided After
Finalization Of Pt Vender By Contractor. (2) Rates Of PT beams
Includes All Ancillary Work/Facility/Item To Be Carried Out By
Contractor For Successful Execution Of PT Work. (3) All Required
Reproping For Long Span Beams/Slabs Or Other Critical Elements
Shall Be Carried Out By Contractor Without Any Extra Charge. (4)
Contractor Has To Kept Props For Rcc Elements As Per The
Instruction And Detail From Structural Consultant In Addition To
Standard Norms As Per Is : 456:2006 Without Any Extra Cost. (5) 0.00 RMT
Contractor Has To Make All Required And Necessary Provision To
Support Cantilever Slab/Beams Projections And Elements Which
Required Stagging/Shuttering/Formwork Supporting Height More
Than Normal Height Like Additional; Brackets , Ms Beams Etc.
Without Extra Cost
Brick work using common burnt clay building bricks having
23 crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:6
(1- Cement : 6 -fine sand)(C) Fly Ash Bricks
Ground Floor 82.00 C.M. 4511.97
First Floor 84.00 C.M. 4786.95
Terrace Floor 84.00 C.M. 5061.92
Stair Cabin Top 44.00 C.M. 5379.24
(SOR SMC Pg No. 2 It No. 16)
Half brick masonry in common brunt clay building bricks having
crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4
(1- Cement : 4 - coarse sand ) in foundation and plinth (C)Fly Ash
Ground Floor 722.00 S.M. 678.86
First Floor 722.00 S.M. 685.11
Second Floor 722.00 S.M. 691.37
(SOR SMC Pg No. 2 It No. 17)
Providing & Applying 15mm.th.cement plaster in single coat on
brick/ concrete walls similar surfaces for plastering & finished
25 even & smooth with a floating coat of cement slurry mixed with
admixture of lime or neeru in required proportion etc. comp. in C.M
1:3 (1 cement : 3sand)
(A) for wall and similar surfaces
Ground Floor 1268.00 S.M 237.51
DESCRIPTION Qty. UNIT AMOUNT
First Floor 1271.00 S.M 265.65
Second Floor 1271.00 S.M 293.79
Terrace Floor 76.00 S.M 321.93
(SOR SMC Pg No. 3 It No. 25)
Providing & Applying 10mm.th.cement plaster in single coat on
brick/ concrete walls similar surfaces for plastering & finished
26 even & smooth with a floating coat of cement slurry mixed with
admixture of lime or neeru in required proportion etc. comp. in
C.M 1:3 (1 cement : 3sand)
(B) for ceilings and soffits of stairs
Ground Floor 594.00 S.M 214.60
First Floor 594.00 S.M 242.74
Second Floor 594.00 S.M 270.88
Terrace Floor 29.00 S.M 270.88
(SOR SMC Pg No. 3 It No. 24)
Providing and fixing 150 mm wide, approved quality chicken wire
mesh (FRP / PVC) at junction of brick work and RCC work or two
dissimilar surfaces, at all heights fixed by nails, rowal plugs or tag
by cement mortar 1:3 before applying the plaster, including curing,
scaffolding all complete as directed.
Ground floor 95.00 S.M. 102.00
First floor 97.00 S.M. 102.00
Second Floor 97.00 S.M. 102.00
Terrace Floor 9.00 S.M. 102.00
(SOR SMC Pg No. 11 It No. 124)
Providing 20 mm thick double coat mala cement plaster on
brick / concrete work for plastering comprising of base coat 12 mm
thick cement plaster in cement mortar (1 Cement : 4 coarse sand)
in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1
Cement : 2 Coarse sand) finished with trovel including scaffolding
curing etc. complete.
Ground Floor 439.00 S.M 272.78
First Floor 439.00 S.M 272.78
Terrace Floor 439.00 S.M 272.78
Above SC Floor 202.00 S.M 272.78
(SOR SMC Pg No. 3 It No. 27)
Providing & Applying 20mm. Th. Heavy Roller plaster on walls or
similar surfaces at all floor levels consisting of 12 mm av. Th.
Backing coat of C.M. 1:3 (1 cement:3 sand) & 8 mm. th. Finishing
29 coat of C.M. 1:1 (1cement: 1 sand) apply thick cement slurry and
apply roller horizontal as well as vertical ( two times ) up to good
quality and size of grain in elevation as per directed by engineer
Ground Floor 0.00 S.M 324.00
First Floor 0.00 S.M 324.00
Terrace Floor 0.00 S.M 324.00
LMR Floor 0.00 S.M 324.00
(SOR SMC Pg No. 3 It No. 28) MR
Providing throating or plaster drip and moulding it to R.C.C. chajja
30 etc.comp.. For all floor
Ground Floor 89.00 R.M 41.66
First Floor 89.00 R.M 41.66
(SOR SMC Pg No. 3 It No. 29)
Providing 20 mm deep finished groove in plaster in line and
level etc. Comp. For all Floor (M.R.)
Ground Floor 90.00 R.M 50.00
First Floor 90.00 R.M 50.00
(SOR SMC Pg No. 3 It No. 30) MR
DESCRIPTION Qty. UNIT AMOUNT
Providing and laying Vitrified tiles 8 to 10 mm thick, 24" x 24" in
flooring treads of steps and landing laid on a bed of 12mm thick
cement mortar 1:3 (1 cement : 3 coarse sand) finishing with flush
pointing in white cement.
Ground Floor 442.00 S.M 1040.35
First Floor 442.00 S.M 1040.35
(SOR SMC Pg No. 4 It No. 44)
Providing and laying Vitrified tiles 8 to 10 mm thick, 24" x 24" in
skrting risers of steps and dedo on 10mm thick cement plaster 1:3
(1 cement : 3 coarse sand) and jointed with white cement slurry.
Ground Floor 164.00 S.M 1081.71
First Floor 164.00 S.M 1081.71
(SOR SMC Pg No.4 It No. 45)
Providing & laying Vitrified tiles of 8mm thick of Orient,
Kajaria,Jhonson, Nitco, Somani, Bell, Asian or Euro make in
flooring,treads of steps & Landing laid on bed of 20 mm (Average)
base of cement mortar 1:6 (1 Cement : 6 Coarse sand) on new
34 surface or fixing on existing flooring by adhesive material including
dismentaling of existing flooring and jointed with colour cement
slurry including finished with flush pointing & cleaning the surface
etc. comp.Size 24" x 24" For Antiskid tiles
Ground Floor 21.00 S.M 1397.83
First Floor 21.00 S.M 1397.83
(SOR SMC Pg No.4 It No. 43)
Providing and laying polished Kota stone slab flooring over 20mm
(Average) thick base of cement mortar 1:6 (1-cement : 6-coarse
sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and
35 jointed with grey cement slurry mixed with pigment to match the
shade of slab including rubbing and polishing etc. complete. (A)
Ground Floor 45.00 S.M 989.45
First Floor 0.00 S.M 989.45
(SOR SMC Pg No.4 It No. 32)
Providing and laying polished Kota stone slab 25mm thick in risers
of steps,skirting Dedo and pillars laid on 10mm thick cement
mortar 1:3 (1-cement : 3-coarse sand) and jointed with gray
cement slury mixed with pigment to match the shade of slab
including rubbing and polishing etc. complete.
Ground Floor 0.00 S.M 1076.94
First Floor 0.00 S.M 1076.94
(SOR SMC Pg No.4 It No. 33)
Providing and constructing sandwitch type Granite stone platform
0.6 mt. wide & 0.75 mt. height, including one end side granite stone
(Double Polish) of 1.25 mt. height & front granite stone patti of
cm wide, vertical partitions of half B.M. wall in C.M. 1:4 and 10mm
th. plaster in 1:3 with finishing smooth with cement slurry as
required and Stainless Steel sink of 0.45 mt x 0.45 mt size of
approved quality and make with required all fitings & fixitures etc.
comp as per instruction given by site in charge at all floors. (Basic
rate of Granite Rs.1,200.00 / S.M.)
All Floor 11.00 R.M. 3128.00
(SOR SMC,Pg No.11, It No. 123) MR
Providing and filling in depressions of Bath and W.C. At all floor
levels, after completing plumbing work of pans, pipes,traps etc.with
38 cinder or fly ash as directed by Engineer in charge etc. comp.For all
All Floor 36.00 S.M 500.00
(SMC SOR,Pg No.6, It No. 61) MR
DESCRIPTION Qty. UNIT AMOUNT
Providing & fixing 35mm.th. Indian teak wood shutters for
doors, windows &clearstory windows incl. Indian teak wood
39 frames of finished size 12cm x7cm.incl. anodized aluminum
fixtures & fastenings incl. Primer coat of approved quality & two
coats of oil painting etc. For all Floor (A) Fully Panelled
All Floor 30.00 S.M 5533.68
(SOR SMC Pg No.5 It No. 53)
Providing and fixing FRP frame size 125x65 mm and 35 mm
thick FRP shutter with wood grain raised panneled design
finish shutter having extra reinforcement on sides & edges in Gel
coat finish. The core of the shutter & frame is to filed up with
injected polyurethane foam done in situ along with embedded
40 wooden pieces for stiffening & also taking hinges & fintures. The 23.00 S.M
whole FRP frame & shutter is to be water proof weather proof,
termite proof & resistance to mild acid/alkali. Rates are to be
inclusive of S.S. hinges with fastener sleeve & alluminium fixtures &
fasteningsFor all Floors.
(SMC SOR,Pg No.5, It No. 55)
Providing & fixing 35mm.th. Flush Door Solid Double Core type
Both Face water proof Ply Vennered & 1.5 mm th.laminate shall
be pasted on both side with adhesives as specified by the
manufacturers. The laminate shall be as per approved shade &
texture, of make incl. Sal wood frames of finished size 12cm x
7cm.incl. S.S. Hinges with nessary screws & Anodized aluminum
fixtures & fastenings For all Floor
(SOR SMC Pg No.5 It No. 51) MR
Same as Above But Without Frame
All Floor 28.00 S.M 2520.00
(SOR SMC Pg No.5 It No. 52) MR
Providing and fixing window having extruded aluminium colour
anodized section frame main outer size 63.50 x 38.10 x1.95 mm (of
Jindal section no.4605, @ Wt. 1.094Kg/mt) horizontal Two track
member size 61.85 mm x 31.75 mm x 1.20 mm (of jindal section
no:8687, @ Wt. 0.695 Kg/mt.) vertical member of size 61.85 mm x
31.75 mm x 130 mm (of jindal section no:8758 @ wt. of
kg/mt) with sliding shutters of horizontal member size 40 mm x18
mm x 1.29 mm ( of jindal section no:8949, @ Wt. of .456 Kg/mt)
vertical member of size 40 mm x 18 mm x 1.29 mm (of jindal
section no:8947, @ Wt. of 0.456 Kg/mt/section 8948, @ Wt. of
0.457 Kg/mt) with 5 mm thick tranparent bronze colour tineted
float glass with powder coated aluminium fittings and fixtures and
transparent silicon sealant glass fixing to frame as per details etc.
complete for window.For all Floors.
(A) Same as above but colour anodized 10.00 S.M 1705.67
SMC SOR Alluminium Work ITEM NO.3(A),Pg No.17
DESCRIPTION Qty. UNIT AMOUNT
Providing and fixing window having extruded aluminium
POWEDER COATED section frame main outer size 95 mm x 24 mm
x 1.17 mm (of jindal section no:2459 @ Wt. of 0.738 Kg/mt),
horizontal Three track member size 92 mm x 31.75 mm x 1.30 mm
(of jindal section no;8688, @ Wt. 1.07 Kg/mt), vertical member of
size 92 mm x 31.75 mm x 1.50 mm (of jindal section no:8933, @
Wt. 1.06 Kg/mt) with sliding shutters of horizontal member size
43 mm x 18 mm x 1.29 mm (of jindal section no:8947 @ wt. of 0.456 0.00 S.M
kg/mt), vertical member of size 40 mm x 18 mm x 1.29 mm (of
jindal section no:8949 @ wt. of 0.456 kg/mt) with 5 mm thick
transparent bronze colour tinted float glass with powder coated
aluminium fittings & fixtures and transparent silicon sealant glass
fixing to frame as per details etc.
(A) Same as above but colour anodized
All Floor 141.00 S.M 1591.87
SMC SOR Alluminium Work ITEM NO.2(A),Pg No.17
Providing and fixing standared extruded ofalluminium section of
size 63mm x 38.10mm x1.2mm , @ Wt. 0.643 Kg/mt with colour
44 Powder Coated alluminium frame for ventilation with 5 mm thick 0.00 S.M
frosted glass as details etc complete for Ventilation
A) Same as above but Colour anodized 6.00 S.M 2414.00
SMC SOR Alluminium Work ITEM NO.4A,Pg No.17 MR
Providing & laying granite slab 18 mm thick in Window-Door
seal,Frames Etc laid on 10 mm thick cement mortar 1:4 (1
Cement: 4 Coarse sand) with necessary adhesive material and
finished with flush pointing in white or colour cement, including
rubbing & polishing comp. (Basic Rate: Rs. 1000.00/S.M.).For all
For all Floors. 269.00 S.M 2026.00
SMC SOR , PAGE No.4 ITEM NO.41 MR
46 Labour Charges For Edge Finished For Granite for all floors
For all Floors. 3310.00 R.M 43.43
SMC SOR, PAGE No.4 ITEM NO.42
Providing & fixing M.S.Grills of required pattern to wooden frames
of windows etc. At all floor levels with M.S. flats at required spacing
& frame around square or round bars with round headed bolts &
round headed bolts and nuts or by screws incl. Priming coat of Red
lead paint etc. comp. (A) Plain grill For all Floors
(A) Plain grill
For all Floors. 3800.00 Kg. 104.20
SMC SOR, PAGE NO 5 IT NO
Painting two coat (excluding priming coat) on new steel and other
metal surface with synthetic enemal paint, burshing to give an even
48 shade including cleaning the surface of all dirt, dust and other
foreign matters. (A) For plain grill For all Floor
For all Floors 173.00 S.M 65.31
SMC SOR, colour works,item no.-8,Pg No.15
DESCRIPTION Qty. UNIT AMOUNT
Providing and fixing stainless steel ( Grade 304) railing made of
Hollow tubes, channels, plates etc., including welding, grinding,
buffing, polishing and making curvature (wherever required) and
fitting the same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary accessories &
stainless steel dash fasteners , stainless steel bolts etc., of required
size, on the top of the floor or the side of waist slab with suitable
arrangement as per approval of Engineer-incharge, (for payment
purpose only weight of stainless steel members shall be considered
excluding fixing accessories such as nuts, bolts, fasteners etc.)
SMC SOR, ITEM NO 120,Pg No.11, MR 675.00 Kg. 450.00
(1) The whole work is to be executed through specialized agency
50 with a guarantee of 10 (Ten) years given on a prescribed proforma
duly stamped (2) The rate shall include for work at all floors &
B) Providing and laying integral cement based water proofing
treatment including preparation of surface as required for
treatment of roofs, balconies, terraces etc. consisting of following
operations. (a) Applying and grouting a slurry coat of neat cement
using 2.75 kg/sqm of cement admixed with proprietary water
proofing compound comforming to IS:2645 over the R.C.C. slab
including cleaning the surface before tratment.(b) Laying cement
concrete using broken bricks/brick bats 25 mm to 100 mm size
with 50% of cement mortar 1:5 (1 Cement : 5 Coarse sand)
admixed with proprietary water proofing compound conforming to
IS:2645 ,brick bats is finally covered by jointless cement plaster
20mm th. in C.M. 1:4 added with special water proofing compound
confirming to IS:2645 & top smooth finished with trowel with false
chequered marking of 300 mm.size.The treatment is carried along
the vertical surface of the parapet & other adjoining wall up to
height of about 300 mm in a shape of quarter round vata Incl.
curing etc. Comp. With average thickness of 120 mm and minimum
thickness at khurra as 65 mm.
(c) The whole terrace so finished shall be flooded with water for a
minimum period of two weeks for curing and for final test. All
above operations to be down in order and as directed and specified
by the engineer-in-charge. With average thickness of 120 mm and
minimum thickness at khurra as 65 mm. (Cement consumption
0.511 Bags / S.M.)
Terrace and staircabin top 607.00 S.M 511.00
SMC SOR, PAGE NO 6 IT NO 62 B M.R.
(A) Providing and laying water proofing treatment to vertical and
horizontal surfaces of depressed portions of W.C.,kitchen and the
like consisting of :
(a) I course of applying cement slurry @ 4.4 kg/sqm mixed with
water proofing compound conforming to IS : 2645 in recommended
(b) II course of a layer of plaster in C.M. 1:3 with water proofing
compound confirming to IS:2645 about 25 mm. th' in the floor of
the depression & about 18mm th' On the side walls of the
depression up to the floor level, water proofing plaster about
mm. th' be continued on the walls above the floor level for a height
of 600 mm. with surface suitable to receive further treatment
(c) Finishing top with stone aggregate 10mm to 12mm nominal
size spreading @0.008 C.M./S.M., thoroughly embedad in plaster
layer. as per specifications & instructions of Engineer in charge
(Cement consumption 0.316 Bags / S.M.)
DESCRIPTION Qty. UNIT AMOUNT
For all Floors 87.00 S.M 296.00
SMC SOR, PAGE NO 6,IT NO 62 B M.R.
Providing and laying broken china mosaic flooring for terrace
using 12 mm to 20 mm broken pieces of glased tiles of to be laid
over cementr morter 1:3 to plain or slope and to be tempered to
51 bring morter crème out up to surface using white cement including
grounding off jnctions and extending them up to 15 cm along the
wall, clearing with water and oxalic acid etc as directed.
SMC SOR, PAGE NO 12 IT NO 131 607.00 S.M 747.29
Apply two coats of putty and two coats of primer of approved
brand and manufacture on new wall surface to give an even shade
52 including thoroughly brushing the surface free from mortar
dropping and other matter and sand papered smooth.
(A) for wall and similar surfaces
For all Floors 3890.00 S.M 40.59
(B) for ceilings and soffits
For all Floors 1838.00 S.M 40.59
SMC SOR ,coiour works,Pg No.15,item no.-4
Wall painting (two coats) with plastic emulsion paint of approved
brand and manufacture on undecorated wall surface to give an
53 even shade including throughly brushing the surface free from
mortar droppings and other foreign matter and sand papered
(A) for wall and similar surfaces
For all Floors 3890.00 S.M 79.39
(B) for ceilings and soffits
For all Floors 1838.00 S.M 79.39
SMC SOR , coiour works,Pg No.15,item no.-5
Providing & applying two coats of weather shield max paint (3
coats may be required in case of darker colours.)of ICI Dulux or
Apex Ultima of Asian Paint including applying exterior acrylic
primer coat as per manufacturers specification and directions in
shade and colour approved by architects, on exterior surfaces of
the building including scaffolding, preparing the surface, watering,
curing etc. complete and as directed by the architects and
Surface Preparation : surface is thoroughly clean, dry and free
from all loose dirt, chalk, grease, fungi, algae and flaking paint. This
can be achieved by brushing with a wire/ stiff coir brush, followed
54 by water jetting if required. Fill up all minor cracks and defects
with white cement and sand mixture in the ratio 1:3. For
application on previously painted wall, previous coatings of paint
must be thoroughly scraped off and Clean the surface thoroughly
using wire brushes. Priming: Apply a liberal coat of exterior acrylic
primer and allow it to dry for 4-5 hours. Application of putty is not
recommended. Minimum 4-6 hours duration is required between
each coat of weather shield max paint.For all Floors.
For all Floors 1519.00 S.M 82.00
SMC SOR, coiour works,Pg No.16,item no.-17
Providing and applying textured plaster as per design of ICI Dulux
or of Asian paint as per manufacturers specification and directions
in shade and colour approved by architects, on exterior surfaces of
the building including scaffolding, preparing the surface, watering,
curing etc. complete and as directed by the architects and
DESCRIPTION Qty. UNIT AMOUNT
Providing & laying granite slab 18mm thick in flooring, treads of
steps and landing laid on bed of 20mm thick cement mortar 1:6 (1
Cement : 6 coarse sand) or lime mortar 1:1.5 laid and finished with
56 flush pointing in white or colour cement including rubbing and
polishing complete. (Basic Rate:- Rs.1347.46/S.M.)
For all Floors. 108.00 S.M 2410.00
SMC SOR PAGE NO 4,IT NO 39 M.R.
Providing & laying granite slab 18mm thick in skirting, risers of
steps,dedo and pillars laid on 10mm thick cement mortar 1:4 (1
57 Cement : 4 Coarse sand) and finished with flush pointing in white
or colour cement including rubbing & polishing comp.. (Basic Rate:-
SMC SOR PAGE NO 4,IT NO 40 M.R. 29.00 S.M 2449.00
Providing and fixing M.S. Fan clamps type 1 to 16 mm dia M.S. bar
bent to shpe with hooked ends to RCC slabs curing, layig including
painting the exposed portion of loops, all as per standard design
For all Floors. 120.00 Nos 129.02
SMC SOR , PAGE NO 5, IT NO
Steel work welded in built up sections, framed work including
cutting, hoisting, fixing in position and applying a priming coat of
59 (A) in beams & joists channels angles, tees, flats with connection
plates or angle cleats as in main & cross beams,hip & trussed
purlins connected to common raffers & the like. For all Floor
For all Floors. 16.00 Qtl. 9047.86
SMC SOR ,Pg No.9,IT NO 98(A)
Providing & Fixing Polycarbonate sheet roofing with surface of
the sheet is coated with an anti-UV Co-extrusion layer having good
weather resistance, it can maintain its optical properties and
mechanical performance for a long time. Fasting is usually done by
screws. , The fastening screws should beinserted about 500 mm
apart and 300mm apart Along the supporting internal purlin and
60 edge pulin.All fixing holes with diameter at least 2 mm larger than
screw must be predrilled into each screw location. The screws
should be 6mm diameter with length according to sheet thickness
and corrosion resistant, with at least heavy duty hot dripped
galvanized or stainless steel. Excluding the cost of purlins rafter
(b) 2 mm thick Solid Sheet 9.00 S.M 1510.00
Extra for additional height of proping and centering where the
height of proping and centering exceed 4.0M between supprting
floor to ceilng including temporary brick or stone pillars for
suporting as required
1) height more than 4.0M and upto 5.0M 1721.00 S.M 390.34
2) height more than 5.0M and upto 6.0M 150.00 S.M 688.83
R&B SOR, Pg No.75 ,Item no.-09002AA/09002BA
Providing & fixing in position collapsible steel shutters with
vertical channels 20 x10 x 2 mm. Braced with flat iron diagonals
x5mm size with top & bottom rails of T-iron 40x40x6mm. with
38mm dia. steel pulleys comp. with bolts, locking arrangements,
stoppers, handles incl. applying a priming coat of Redlead paint
Ground Floor 52.00 S.M 5865.10
SMC SOR , PAGE NO 5, IT NO
DESCRIPTION Qty. UNIT AMOUNT
Masonary work using AAC Block Aerated light weight concrete
block having crushing strength not less than 35 kg/sqcm for super
63 structure above plinth level upto floor two level in cement
mortar 1:5 ( 1 cement : 5fine sand ) complete as per Technical
Ground Floor ( 1ST SLAB ) 0.00 C.M 4854.12
(LIBRARY & RECREATION CENTER AT P.T.P.S. NO.
(KATARGAM), F.P.NO 133, IT:31 SCDUAL B )
Providing & fixing at all floor levels,both face polished machine
cut edge Marble slab for Shelve joined with grey/White cement
slurry (1:1) incl. Rubbing & polishing etc. complete. (M.R.) (Basic
Cost Rs. 450/S.M.)
SMC SOR, PAGE NO.7,IT NO 66 (MR) 19.00 S.M 1050.00
Providing, fixing, fitting S.S. Latter of quality SS 304 or with
colour powder coating incliuding Necessary fixture & Fastaning
with scaffolding etc. complete. As per requirement & Direction of
Engineer in Charge.
RATE as Per EZ_B bord and S.S logo Samati for TPS NO.22 , F.P.
NO.76 (SARTHANA) incd GTS ITEM
Providing, Approving designing and supplying 6mm thick white
Acrylic computer Laser cutting Latter including necessary
scaffolding, pasting on ACP sheet or similar surfaces, etc. complete.
RATE as Per EZ_B bord and S.S logo Samati for TPS NO.22 , F.P.
NO.76 (SARTHANA) incd GTS ITEM
67 Wall Vinyl Sticker 44.00 SQ. FT. 28.00
SMC SOR, PAGE NO.13,IT NO 146 (MR)
Eco Solvent Vinyl Sticker (120 gsm) with Lamination (100 gsm)
SMC SOR, PAGE NO.13,IT NO 147 (MR)
69 Solvent Vinyl Sticker (120 gsm) with Lamination (100 gsm) 44.00 SQ. FT. 22.00
SMC SOR, PAGE NO.13,IT NO 148 (MR)
70 5mm PVC sheet Eco Vinyl (Any size) 44.00 SQ. FT. 55.46
SMC SOR, PAGE NO.13,IT NO 149 (MR)
Decorative theme base designing & painting with all waterproof
SMC SOR, PAGE NO.13,IT NO 150 (MR)
DESCRIPTION Qty. UNIT AMOUNT
WATER SUPPLY & SANITATION
Prov.& Fixing water closet squatting pan (Orissa type W.C.pan) at
all floor levels, size 500mm x 400 mm incl. 100 mm size "P'or "S"
72 trap for water closet squatting pan joining the trap with the pan &
soil pipe in C.M. 1:1 (1cement :1 fine sand) etc. Comp.(A) Vitreous
china long pattern
Make- Cera S3010109, Parry ware C0117CS/C0117* , Jaquar
For all Floors. 1.00 Nos. 3275.00
SMC sor- Sanitary Items, Page no22, It No.
Providing and fixing Wash Down Water closet European type W.C.
pan with integral P or S trap with normal closing seat cover L bend
73 ncluding jointing the trap with soil pipe in cement mortar 1:1 (1
cement : 1 find sand) (A) Viterous china pattern - I
Make- Cera CONVENTIONAL B1510121 , Parry ware C0297*/
C0278, HindWare sleek 20011, Jaquar- CNS-WHT-751P180SPPZ
For all Floors. 15.00 Nos 3282.00
SMC sor- Sanitary Items,Page no21,It No.
Prov.& Fixing Health Faucet ABS Body with wall Hook and 1 Meter
chrome plated PVC Hose Pipe
Make- Cera F8030106AB, Parry ware T9874A1, Jaquar ALD-587
,HindWare F160109
For all Floors. 15.00 Nos 971.00
SMC sor- Sanitary Items, Page no22, It No.
Providing Metropole Flush Valve Dual Flow 40mm
75 Size (Concealed Body)
Make- Cera F8010202 , Parry ware T3302A1 , Jaquar FLV-1089NSQ
,HindWare F860075
For all Floors.
SMC sor- Sanitary Items, Page no22, It No.
Providing & fixing Wash Hung basin with single hole for pillar tap
, Size- 550 x 400 mm at all floor levels, with C.I. or M.S. Brackets
painted white incl. cutting holes & making good the same etc.
complete. For all Floor
Make- Cera Cat. No. S2040121, Parry wareC0434* (CTH), Jaquar
SLS- WHT -6801 ,HindWare10004
For all Floors. 10.00 Nos 2656.00
SMC sor- Sanitary Items, Page no21, It No.7
Providing & fixing 600 mm.x 450 mm. mirror of superior glass
at all floor levels, mounted on 6 mm. th. A.C. sheet or plywood
sheet & fixed to wooden plugs with C.P.brass screws and washers
etc. For all Floor
All Floor 10.00 Nos 833.73
SMC sor Page no7 , It No.72
Providing & fixing C.P. brass pillar cock with copper connection,
C.P. brass screws complete
Make- Cera F2013101, Parry ware Cat. No.: G3102A1, HindWare
Cat. No.: F650003, Jaquar FLR-5011N
For all Floors. 10.00 Nos 1423.00
SMC sor Sanitary Items,Page no21, It No.
Providing & Fixing 15 mm Dia bib tap with wall Flange at all floor
levels, polished bright etc. comp
Make- Cera F2013151 BIB COCK, Parry wareG3104A1, HindWare
F280002 BIB COCK, Jaquar FLR-5047 N BIB COCK 30.00 NO
SMC sor Sanitary Items,Page no21, It No.
Providing & Fixing 15 mm Dia 2 way bib tap with wall Flange at all
floor levels, polished bright etc. comp
DESCRIPTION Qty. UNIT AMOUNT
Make- Cera F2013163, Parry ware G4834A1, HindWare Cat. No.:
F530004, Jaquar FLR-5041N
SMC sor Sanitary Items,Page no21, It No.
Providing flush cock consisting lever, cartridge sleeve & flange &
Make- Cera EXPOSED PART F2013751 &Concealed part F4060101
Parry ware T9824A1&T9823A1, Jaquar FLR 5083 KN , CONCEALED
BODY ALD-081,HindWare F280052 & CONCEALED STOP COCK
All floor 15.00 NO 2110.00
SMC sor Sanitary Items,Page no21, It No.
Providing & fixing 15mm C.P. brass angle valve (Stop Cock) with
C.P. copper connecting pipe 450 mm long and nuts, washer and
82 brass flange complete, including cutting and making good the wall
where required.
Make- Cera F1020362, Parry ware T0712A1, HindWare Cat. No.:
F440020 F850094, jaquar CON 053 KN
For all Floors. 10.00 Nos 1432.00
SMC sor- Sanitary Items,Page no21,It No.
Providing and fixing Towel Ring fabricated from seamless
stainless steel tube 2mm thick in bath room with polished wall
flange at end of bars with heavy duty anchor fasteners &
Make- Cera F5014115CH, Parry ware F5014115CH, Jaqua ACN
1121N ,HindWare F880007
For all Floors. 10.00 Nos 890.00
SMC sor Sanitary Items,Page no21,It No.
Providing & Fixing stainless steel recessed type Soap dish of
84 approved make. Including providing & fixing screws, washers,
cutting & making good the walls.
Make- Cera F5007106, Parry ware T6902A1, Jaquar ACN-
1131N,HindWare F880011
For all Floors. 10.00 Nos 793.00
SMC sor Sanitary Items,Page no21,It No.
Providing and fixing PVC SWR Nahni trap IS 14735 for drain -
mm diameter with jali of the following nominal diameter of self
85 cleaning design with C.I. scread down or hinged grating including
the cost of cutting and making good the walls.
All floor 30.00 No. 558.36
SMC sor.Page no 8,It No.
Providing & Fixing U-PVC pipe (SWR) confirming to IS no.
(Type"B") of Prince/ Supreme/ Jain/ Astral/ Tulsi/ Finolex make
86 for soil and waste discharge system at all floor levels incl. All
fixtures like bends, tees,shoe etc. jointed with resin of approved
brand & manufacture etc. comp.(M.R.)
SMC sor,Page no 8 It No. 84 M.R.
Providing & fixing U-PVC pipes Confirming to IS no. 13592 (Type
"A") of Prince/ Supreme/ Jain/ Astral/ Tulsi/ Finolex make for rain
87 water at all floor levels incl. fixtures like bends, tees, shoe etc
joined with resin of approved brand & manufacture etc. comp.
(M.R.) (A) 75 mm. Dia.
SMC sor ,Page no 8, It No. 85 M.R.
Providing and fixing in position P.V.C. cowl vent to pipes of prince,
suprime, jain Or Eqivalent make etc. comp (M.R).
DESCRIPTION Qty. UNIT AMOUNT
SMC sor- Page no.8, It No.
Providing & Fixing Kathi around the vertical PVC drainage pipes for
concealing with cement plaster 20 mm avg thickness(CM 1:3 [1
89 cement :3 coarse sand]) finishing as per instruction given by Eng.
75mm PVC pipe 151.00 R.M 173.00
SMC sor- Page no.8, It No. 93 MR
Providing, Laying and jointing on true line and level UPVC pipe
(SCH-40) line of prince/Supreme/Jain/Astral/ Tulsi/Finolex make
including fittings make or equivalent as approved by angineer-in-
charge. Pipe shall be fixed on the wall the help of clamp at every
two meter C/C or shall be concealed as directed including
necessary fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all materials.
SMC sor Page no 8 It No.
Providing & Fixing P.V.C. pipes (SCH-80) of Prince/ Supreme/
Jain/ Astral/ Tulsi/Finolex make for water supply line at all floor
levels incl. fixtures like bends, tees, shoe etc joined with resin of
approved brand & manufacture etc. comp. Pipe shall be fixed on the
91 wall the help of clamp at every two meter C/C or shall be concealed
as directed including necessary fittings etc. including testing of
pipe and joints and fixing the same with adhesive solvent, including
cost of all materials.
SMC sor Page no8 It No. 87 MR
Providing and fixing M.S. holder bat clamps at all floor level,of
92 approved design to C.I. or S.C.I pipes including cost of cutting holes
and making good the wall etc. comp. (M.R)
SMC sor- Page no8, It No. 90 MR
Providing and fixing G.I. holder "Z" clamps at all floor level,of
93 approved pipes including cost of cutting holes and making good the
wall etc. comp. (M.R)
(C) 150 mm to 200 mm dia 0.00 NO 98.00
SMC sor- Page no 11, It No. 121 M.R.
Providing and fixing gun metal check or non return full way wheel
valve at floor levels,etc. complete.
SMC sor Page no8,It No.
Providing and fixing abonite ball cock of approved quality as
directed etc. comp.
SMC sor- Page no 8,It No.
DESCRIPTION Qty. UNIT AMOUNT
Providing, Lowering and laying joining R.C.C. NP2 CLASS pipe in
cement mortar in proportion 1:1 of following nominal internal
diameters including testing of pipes and joints etc. complete.
SMC sor- Page no.7, It No.
SMC Storm drainage SOR 22-23, Page no1 It No.1
Providing and fixing s.w. Gully trap with C.I. gratting brick
masonary chamber and water tight Pre cast R.C.C.cover of 300mm
X 300mm size (inside) including plastering smooth inside and
outside 15 mm thick in C.M 1:3 etc. comp.i) square mouth traps
(A)300 MM X 300 MM Size - P type.For all Floors.
SMC sor,Page no 7, It No.
Prov. & Fix. 10 cm.x15 cm.(4" x 6") S.W. trap with Inside
dimension ,455 x 610 mm & 450 mm deep sewer trap chamber
with 23 cm th' B.B. masonary walls in C.M 1:5 with cement plaster
15 mm th' in C.M. 1:3 inside & outside to exposed faces, R.C.C. top
98 slab with 1:2:4 mix ( 1 cement: 2 Sand : 4 Grade stone aggregate 0.00 No.
20mm size) ,Foundation concrete 1:5:10 & fixing C.I. cover with
frame to be not less than 38 kg. On top etc. comp. for single
pipe.'.(A) Precast RCC heavy duty Cover instead of C.I. Cover
(A).Same as above but Precast RCC heavy duty Cover instead of C.I.
Extra for every additional depth of 0.1 mt.beyond 0.45 mt. 0.00 Each 222.71
SMC sor, Page no.7, It No.75
Providing & construction simple chamber of 23 cm. th' B.B.
Masonary in C.M 1:5 with cement plaster 15 mm th' in C.M. 1:3
inside & outside to exposed faces, R.C.C. top slab with 1:2:4 mix (
99 cement: 2 Sand : 4 Grade stone aggregate 20mm size), Foundation 0.00 No.
concrete 1: 5: 10 & fixing C.I. cover with frame to be not less than
38 kg. On top etc. comp. Inside dimension, 455 x 610 mm &450 mm
deep for single pipe
(A).Same as above but Precast RCC heavy duty Cover instead of C.I.
Extra for every additional depth of 0.1 mt.beyond 0.45 mt. 0.00 Each 242.39
SMC sor - Page no7,It No.76
Providing and fixing C.I. Machinehole cover 0.60 x 0.45 mt. Size
having weight not less than 35 Kg. etc. complete.
SMC sor- Page no.8, It No. 83 12.00 NO 958.17
Providing and fixing G.I, Rain water spout of 50 mm dia and 30 cm
SMC sor- Page no6 It No. 64 15.00 NO 101.91
Providing & fixing white vitreous china urinal of size 450 x325mm
as per IS-2556 (Part-2 ) with C.I. hangers and 15mm dia. C.P.
102 spreader,32mm dia CP bottle trap and pipe to wall with C.P. flange
complete including cutting and making good the walls and floors
wherever required.
Make- CeraCat. No. S4020103, Parry ware C0501*, Jaquar URS-
WHT 13261H ,HindWare BACK SMALL 60001
SMC sor- Sanitary Items,Page no.21, It No.8
Providing & fixing at all floor levels,both face polished machine cut
edge Marble slab for urinal partition joined with grey/White
cement slurry (1:1) incl. Rubbing & polishing etc. complete. (M.R.)(
Basic Cost Rs. 450/S.M.)
SMC sor- Page no7 It No. 66 MR 13.00 S.M 1050.00
DESCRIPTION Qty. UNIT AMOUNT
Providing & laying ordinary C.C.1:1.5:3 mix for R.C.C. work incl.
boxing, centering, vibrating, curing & mixed with approved water
proofing cement compound or "CEMWET"or"PIDICRETE
LW"integral water proofing admixture as water proofing agent to
be mixed with 50 kg. cement bag shall be as recommended by the
manufacture of the water proofing material, concrete work for top,
bottom slab & side pardi for Under ground Tank & Item incl.
Necessary excavation & refilling the available earth, 15 cm th' C.C
104 1:4:8 for bedding concrete, Half B.M. in C.M. 1:4 outside wall, inside
R.C.C. pardi as per design, 10mm.th. water proofing cement plaster
in C.M. 1:3 with smooth finishing,watering etc.Comp.to all inner
face & bottom of tank curing etc. comp. incl. Locking arrangement,
outlet, inlet, overflow & wash out pipe arrangement as necessary &
C.I. Cover 0.60 x .045 weight not less then 35kg. etc. com. as per
structural drawing excluding Steel & as directed by Engineer-in-
Under Ground water Tank 10000.00 Lit 5.46
SMC sor - Page no6. It No.
Providing & Laying white glazed tiles 6mm. th. of Orient, Kajaria,
Jhonson, Nitco, Somani, Bell make at all floor levels, in flooring,
105 treads of steps & landings laid on a bed of 12 mm. Av. Th.C.M.1:3
(1cement : 3 sand) finished with flush pointing in white cement
etc.com. For all floors
Under Ground water Tank 31.00 SM 857.42
SMC SOR, Page no4, It No.
Providing & Laying white glazed tiles 6mm. th. Of Orient, Kajaria,
Jhonson, Nitco, Somani, Bell make at all floor levels in skirting
risers of steps & dado on 10 mm. th. C.M.1:3 (1cement :3 sand)
including necessary cement paste for fixing and joined with white
cement slurry etc.complete. For all floors
Under Ground water Tank 86.00 SM 887.64
SMC SOR, Page no4, It No.
Providing & fixing IS Mark TMT FE 500D reinforcement for R.C.C.
107 work incl. bending, binding & placing in position etc. comp. Upto
Upto G.L./P.L. 1180.00 Kg. 76.21
SMC SOR- Page no1, It No.
Providing erecting and fixing double coated Sintex/Super/Reno
PVC (ISI) mark water tank of required capacity each with all
necessary fittings & connection etc. complete on terrace.
SMC SOR- Page no 8, It No.
WORK UP TO PLINTH LEVEL
Excavation for foundation including sorting out and stacking off
useful materials and disposing of the excavated stuff up to 50 mt.
lead and all lift, watering etc.comp. (A) loose or soft soil
Executed With Mechanised Efforts / Machinaries
(1) Up to 1.5 mt. Depth 879.00 C.M. 117.26
SMC SOR-PAGE NO 1 IT NO
Boring holes 3.5 mt.deep in ordinary soil ( for cast in situ piles) &
2 disposal of the surplus excavated soil as directed within a lead of
50 M. For following diameter of piles.
250mm dia 53.00 Rmt 326.84
SMC SOR , ITEM NO. 94, PG. NO.
Providing & Filling Rubbles including hand packing & filling
interstics with Quarry Spalls complete for all leads and lifts.
DESCRIPTION Qty. UNIT AMOUNT
SMC SOR , ITEM NO. 22, PG. NO. 3 82.00 C.M. 1064.80
Providing & laying C.C 1:3:6 (1cement : 3 coarse sand : 6 Crushed
4 stone agg 20m.m Nominal size) &curing comp. excl. cost of form
work in :(a) foundation & Plinth
(A) Foundation 50.00 C.M. 3005.76
(C) Grade Slab 6.00 C.M. 3005.76
SMC SOR, PAGE NO 1 IT NO
Providing & laying cement concrete 1:2:4 (1 cement : 2 sand :
graded stone agg. 20 mm nominal size) & curing comp. Includ. cost
5 of form work but exclu. Cost of reinforcement for reinforced
concrete work in : (A) Foundation, footing, Base of columns and
(C) Grade slab 67.00 C.M. 3637.34
(SOR SMC Pg No. 9 It No. 95)
Providing, mixing, placing, compacting by machine vibrator, curing,
testing M25 Design mix concrete as per IS 456:2000 (latest
revision) and as per tender specification in all items including cost
of form work and rendering but excluding cost of reinforcement
(A) foundation, footing, base of columns and mass concrete 98.00 C.M. 4180.62
(SOR SMC - MIX DESIGN PG. NO-14)
Providing, mixing, placing, compacting by machine vibrator, curing,
testing M25 Design mix concrete as per IS 456:2000 (latest
7 revision) and as per tender specification in all items including cost
of form work and rendering but excluding cost of reinforcement
(1) Having cross sectional area up to 0.085sq.mt. 0.00 C.M. 12587.74
(2) Having cross sectional area more than 0.085 sq. mt .up to
(3) Having cross sectional area more than 0.12 sq. mt. 22.00 C.M. 9190.79
(SOR SMC - MIX DESIGN PG. NO-14)
(1) Having cross sectional area upto 0.08 sq.mt. 13.00 C.M. 8994.86
(2) Having cros sectional area more than 0.08 sq. mt and upto
(3) Having cross sectional area more than 0.12 sq. mt . 36.00 C.M. 6999.09
(SOR SMC - MIX DESIGN PG. NO-14)
(1) Slabs having more than 8 Cm & upto 10 Cm thickness. 0.00 C.M. 7887.74
(2) Slabs having more than 10 Cm & upto 13 Cm
(3) Slabs having more than 13 Cm thickness. 4.00 C.M. 6727.93
(SOR SMC - MIX DESIGN PG. NO-14)
(E) RCC Wall - 200 mm Thick 13.00 C.M. 7946.64
(SOR SMC - MIX DESIGN PG. NO-14)
Providing & fixing IS Mark TMT Bar FE 500d reinforcement for
8 R.C.C. work incl. bending, binding & placing in position etc.comp.---
Upto G.L./P.L. 24070.00 Kg. 76.21
(SOR SMC Pg No. 1 It No. 8)
Providing & construction brick work using Fly Ash bricks having
crushing strength not less than 35 Kg./sq.cm. in foundation &
plinth in C.M. 1:6 (1 cement:6 sand ) etc. comp. - Ground Floor
(SOR SMC Pg No. 1 It No. 9) 118.00 C.M. 4237.00
Filling available excavated earth (excluding rock) in trenches.
plinth, sides of foundations etc. in layers not exceeding 20 cm. in
depth consolidating each
disposited layer by ramming and watering.
(SOR SMC Pg No. 1 It No. 10) 1372.00 C.M. 130.39
DESCRIPTION Qty. UNIT AMOUNT
Filling in foundation and plinth with murrum or selected soil in
11 layers of 20cm. thickness including watering, ramming and
consolidating etc. complete.
(SOR SMC Pg No. 1 It No. 11) 461.00 C.M. 289.06
Providing & Applying 15mm.th.cement plaster in single coat on
brick/ concrete walls similar surfaces for plastering & finished
12 even & smooth with a floating coat of cement slurry mixed with
admixture of lime or neeru in required proportion etc. comp. in C.M
1:3 (1 cement : 3sand)
(A) for wall and similar surfaces
Upto G.L./P.L. 56.00 S.M 237.51
(SOR SMC Pg No. 3 It No. 25)
Providing & Applying 10mm.th.cement plaster in single coat on
brick/ concrete walls similar surfaces for plastering & finished
13 even & smooth with a floating coat of cement slurry mixed with
admixture of lime or neeru in required proportion etc. comp. in
C.M 1:3 (1 cement : 3sand)
(B) for ceilings and soffits of stairs
Upto G.L./P.L. 23.00 S.M 214.60
(SOR SMC Pg No. 3 It No. 24)
NOTE :- (1) The whole work is to be executed through specialized
agency with a guarantee of 10 (Ten) years given on a prescribed
14 proforma duly stamped (2) The rate shall include for work at all 145.00 S.M
floors & conducting water proof test as directed. (M.R.)
Proiding & laying water proofing treatment to vertical and
horizontal surfaces like consisting of (a) I course of applying
cement slurry 4.4 kg per sq.mt. mixed with water proofing
compound confirming to IS:2645 in rcommended proportions. (b)
II corse of 20mm cement plaster 1:3 mixed with water proofing
compound in recommended proportion (c) III course of applying
blown or / resideal bitumen applied hot at 1.7 kg per sqm of area.
(d) IV course of 400mm micron th. PVC sheet. (Overlaps at joints of
PVC sheet should be 200mm wide and pasted to each other with
bitumen about 1.7 kg./ sqm.)
(SOR SMC Pg No. 6 It No. 63)
carrying out plinth treatment to post construction/existing
structure by spraying chemical solution for termite control
treatment including labour and material consisting with ISI
specification using chlordene and chiorpurfiles 20 EC as per
15 6131_part II concentration weight one litter give 1% concentration 530.00 S.M.
inclusive of one litter chemicals emulsions application at the rate of
5 litter chemicals /sqmt of surface is recommended as per IS.
(SOR SMC Pg No. 12 It No. 127)
Providing 20 mm thick double coat mala cement plaster on
brick / concrete work for plastering comprising of base coat 12 mm
thick cement plaster in cement mortar (1 Cement : 4 coarse sand)
16 in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1
Cement : 2 Coarse sand) finished with trovel including scaffolding
curing etc. complete.
(SOR SMC Pg No. 3 It No. 27) 318.00 S.M 272.48
DESCRIPTION Qty. UNIT AMOUNT
Providing & applying two coats of weather shield max paint (3
coats may be required in case of darker colours.)of ICI Dulux or
Apex Ultima of Asian Paint including applying exterior acrylic
primer coat as per manufacturers specification and directions in
shade and colour approved by architects, on exterior surfaces of
the building including scaffolding, preparing the surface, watering,
curing etc. complete and as directed by the architects and
Surface Preparation : surface is thoroughly clean, dry and free
from all loose dirt, chalk, grease, fungi,algae and flaking paint. This
can be achieved by brushing with a wire/ stiff coir brush, followed
17 by water jetting if required. Fill up all minor cracks and defects 318.00 S.M
with white cement and sand mixture in the ratio 1:3. For
application on previously painted wall, previous coatings of paint
must be thoroughly scraped off and Clean the surface thoroughly
using wire brushes.
Priming: Apply a liberal coat of exterior acrylic primer and allow it
to dry for 4-5 hours.Application of putty is not recommended.
Minimum 4-6 hours duration is required between each coat of
weather shield max paint
SMC SOR , COLOR WORK ITEM NO.- 17 Page No.
WORK ABOVE PLINTH
Providing, mixing, placing, compacting by machine vibrator, curing,
18 testing M25 Design mix concrete as per IS 456:2000 (latest
revision) and as per tender specification in all items including cost
of form work and rendering but excluding cost of reinforcement
(1) Having cross sectional area up to 0.085sq.mt.
Ground Floor 0.00 C.M. 12587.74
Terrace Floor 0.00 C.M. 12627.34
SC Floor 0.00 C.M. 12666.94
(2) Having cross sectional area more than 0.085 sq. mt .up to
Ground Floor 0.00 C.M. 11136.62
Terrace Floor 0.00 C.M. 11176.22
SC Floor 0.00 C.M. 11215.82
(3) Having cross sectional area more than 0.12 sq.mt.
Ground Floor 21.00 C.M. 9190.79
Terrace Floor 10.00 C.M. 9230.39
SC Floor 0.50 C.M. 9269.99
(SOR SMC - MIX DESIGN PG. NO-14)
(1) Having cross sectional area upto 0.08 sq.mt.
Ground Floor 13.00 C.M. 8994.86
Terrace Floor 0.00 C.M. 9034.46
SC Floor 0.00 C.M. 9074.06
(2) Having cros sectional area more than 0.08 sq. mt and upto
Ground Floor 0.00 C.M. 8075.85
Terrace Floor 0.00 C.M. 8115.45
SC Floor 0.00 C.M. 8155.05
Terrace Floor 0.00 C.M. 8194.65
(3) Having cross sectional area more than 0.12 sq.mt.
Ground Floor 35.00 C.M. 6999.09
Terrace Floor 6.00 C.M. 7038.69
SC Floor 0.00 C.M. 7078.29
(SOR SMC - MIX DESIGN PG. NO-14)
DESCRIPTION Qty. UNIT AMOUNT
(1) Slabs having more than 8 Cm & upto 10 Cm thickness.
Ground Floor 0.00 C.M. 7887.74
Terrace Floor 0.00 C.M. 7927.34
SC Floor 0.00 C.M. 7966.94
Terrace Floor 0.00 C.M. 8006.54
(2) Slabs having more than 10 Cm & upto 13 Cm thickness.
Ground Floor 0.00 C.M. 7306.10
Terrace Floor 0.00 C.M. 7345.70
SC Floor 0.00 C.M. 7385.30
(3) Having more than 13 cm. Thickness
Ground Floor 77.00 C.M. 6727.93
Terrace Floor 5.60 C.M. 6767.53
SC Floor 0.00 C.M. 6807.13
(SOR SMC - MIX DESIGN PG. NO-14)
Ground Floor 4.00 C.M. 9419.25
Terrace Floor 0.20 C.M. 9458.85
SC Floor 0.00 C.M. 9498.45
(SOR SMC - MIX DESIGN PG. NO-14)
Ground Floor 13.20 C.M. 6913.25
Terrace Floor 0.60 C.M. 6952.85
SC Floor 0.00 C.M. 6992.45
(SOR SMC - MIX DESIGN PG. NO-14)
Providing & laying C.C 1:3:6 (1cement :3 coarse sand :6 crushed
19 stone agg. 20 m.m Nominal size)& curing comp. incl. cost of from
work in: wall caps/ copings
(SOR SMC Pg No. 9 It No. 97) 3.70 C.M. 3982.62
Providing, mixing, placing, compacting by machine vibrator, curing,
20 testing M25 Design mix concrete as per IS 456:2000 (latest
revision) and as per tender specification in all items including cost
of form work and rendering but excluding cost of reinforcement
(A) Stair cases including landing etc.
Ground Floor 4.00 C.M. 7158.83
Terrace Floor 0.00 C.M. 7198.43
(SOR SMC - MIX DESIGN PG. NO-14)
(B) Vertical and horizontal fins
Ground Floor 0.00 C.M. 9030.72
Terrace Floor 0.00 C.M. 9070.32
(SOR SMC - MIX DESIGN PG. NO-14)
(C) RCC Wall - 200 mm thick
Ground Floor 0.00 C.M. 7946.64
Terrace Floor 0.00 C.M. 7986.24
(SOR SMC - MIX DESIGN PG. NO-14)
21 Providing & fixing IS Mark TMT Bar FE 500d reinforcement for
R.C.C. work incl. bending, binding & placing in position etc.comp.---
Ground Floor 20305.00 Kg 76.21
Terrace Floor 4979.00 Kg 77.21
SC Floor 150.00 Kg 78.21
(SOR SMC Pg No. 2 It No. 15)
DESCRIPTION Qty. UNIT AMOUNT
Designing, providing and executing Bonded/ Unbonded Post-
tensioning works for slabs/beams/drop panels, etc. Including
decoiling the strands, cutting to the required lengths, supplying and
laying of sheathing (GI corrugated ducts), jointing with couplers
and inserting the strands, profiling, fixing live anchorages suitable
for tendons, grout vents, making dead end anchorages including
lowering the strands, fixing tendon support bars, supervising the
fixing of anti-bursting reinforcement, stressing the cables, end
trimming, grouting the cables with cement and admixtures, with
required plants and machinery tools and tackles, consumables etc.
including co-ordinating with Architectural/Structural consultants
drawings and obtaining approval from client/consultant/Project
Manager for the work done as per the requirement of
Architect/Structural Consultant at site. Also include Area marking
for Post tensioned elements. Area for the same shall be measured
within peripheral RCC beams/walls (Walls/beams not included)
or boundary of the slab etc. including all requisite as per Structural
Engineer instructions.Including all PT memberes (slab & beam)
stagging, shuttering and reproping shall be carried out as per
structural engineer's instruction and suggestion.
(1) All Post Tensioned Beams Detail Shall Only Be Provided After
Finalization Of Pt Vender By Contractor. (2) Rates Of PT beams
Includes All Ancillary Work/Facility/Item To Be Carried Out By
Contractor For Successful Execution Of PT Work. (3) All Required
Reproping For Long Span Beams/Slabs Or Other Critical Elements
Shall Be Carried Out By Contractor Without Any Extra Charge. (4)
Contractor Has To Kept Props For Rcc Elements As Per The
Instruction And Detail From Structural Consultant In Addition To
Standard Norms As Per Is : 456:2006 Without Any Extra Cost. (5) 0.00 RMT
Contractor Has To Make All Required And Necessary Provision To
Support Cantilever Slab/Beams Projections And Elements Which
Required Stagging/Shuttering/Formwork Supporting Height More
Than Normal Height Like Additional; Brackets , Ms Beams Etc.
Without Extra Cost
Brick work using common burnt clay building bricks having
23 crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:6
(1- Cement : 6 -fine sand)(C) Fly Ash Bricks
Ground Floor 151.00 C.M. 4511.97
Terrace Floor 43.00 C.M. 4786.95
SC Floor 6.00 C.M. 5061.92
(SOR SMC Pg No. 2 It No. 16)
Half brick masonry in common brunt clay building bricks having
crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4
(1- Cement : 4 - coarse sand ) in foundation and plinth (C)Fly Ash
Ground Floor 317.00 S.M. 678.86
Terrace Floor 58.00 S.M. 685.11
SC Floor 0.00 S.M. 691.37
(SOR SMC Pg No. 2 It No. 17)
Providing & Applying 15mm.th.cement plaster in single coat on
brick/ concrete walls similar surfaces for plastering & finished
25 even & smooth with a floating coat of cement slurry mixed with
admixture of lime or neeru in required proportion etc. comp. in C.M
1:3 (1 cement : 3sand)
(A) for wall and similar surfaces
Ground Floor 1546.00 S.M 237.51
Terrace Floor 102.00 S.M 265.65
DESCRIPTION Qty. UNIT AMOUNT
SC Floor 0.00 S.M 293.79
(SOR SMC Pg No. 3 It No. 25)
Providing & Applying 10mm.th.cement plaster in single coat on
brick/ concrete walls similar surfaces for plastering & finished
26 even & smooth with a floating coat of cement slurry mixed with
admixture of lime or neeru in required proportion etc. comp. in
C.M 1:3 (1 cement : 3sand)
(B) for ceilings and soffits of stairs
Ground Floor 606.00 S.M 214.60
Terrace Floor 44.00 S.M 242.74
SC Floor 0.00 S.M 270.88
(SOR SMC Pg No. 3 It No. 24)
Providing and fixing 150 mm wide, approved quality chicken wire
mesh (FRP / PVC) at junction of brick work and RCC work or two
dissimilar surfaces, at all heights fixed by nails, rowal plugs or tag
by cement mortar 1:3 before applying the plaster, including curing,
scaffolding all complete as directed.
Ground Floor 108.00 S.M. 102.00
Terrace Floor 8.00 S.M. 102.00
SC Floor 0.00 S.M. 102.00
(SOR SMC Pg No. 11 It No. 124)
Providing 20 mm thick double coat mala cement plaster on
brick / concrete work for plastering comprising of base coat 12 mm
thick cement plaster in cement mortar (1 Cement : 4 coarse sand)
in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1
Cement : 2 Coarse sand) finished with trovel including scaffolding
curing etc. complete.
Ground Floor 550.00 S.M 272.78
Terrace Floor 396.00 S.M 272.78
SC Floor 13.00 S.M 272.78
(SOR SMC Pg No. 3 It No. 27)
Providing & Applying 20mm. Th. Heavy Roller plaster on walls or
similar surfaces at all floor levels consisting of 12 mm av. Th.
Backing coat of C.M. 1:3 (1 cement:3 sand) & 8 mm. th. Finishing
29 coat of C.M. 1:1 (1cement: 1 sand) apply thick cement slurry and
apply roller horizontal as well as vertical ( two times ) up to good
quality and size of grain in elevation as per directed by engineer
Ground Floor 0.00 S.M 324.00
Terrace Floor 0.00 S.M 324.00
SC Floor 0.00 S.M 324.00
(SOR SMC Pg No. 3 It No. 28) MR
Providing throating or plaster drip and moulding it to R.C.C. chajja
30 etc.comp.. For all floor
Ground Floor 109.00 R.M 41.66
Terrace Floor 4.40 R.M 41.66
(SOR SMC Pg No. 3 It No. 29)
Providing 20 mm deep finished groove in plaster in line and
level etc. Comp. For all Floor (M.R.)
Ground Floor 109.00 R.M 50.00
Terrace Floor 5.00 R.M 50.00
(SOR SMC Pg No. 3 It No. 30) MR
Providing and laying Vitrified tiles 8 to 10 mm thick, 24" x 24" in
flooring treads of steps and landing laid on a bed of 12mm thick
cement mortar 1:3 (1 cement : 3 coarse sand) finishing with flush
pointing in white cement.
Ground Floor 432.00 S.M 1040.35
Terrace Floor 20.00 S.M 1040.35
(SOR SMC Pg No. 4 It No. 44)
DESCRIPTION Qty. UNIT AMOUNT
Providing and laying Vitrified tiles 8 to 10 mm thick, 24" x 24" in
skrting risers of steps and dedo on 10mm thick cement plaster 1:3
(1 cement : 3 coarse sand) and jointed with white cement slurry.
Ground Floor 259.00 S.M 1081.71
First Floor 0.00 S.M 1081.71
(SOR SMC Pg No.4 It No. 45)
Providing & laying Vitrified tiles of 8mm thick of Orient,
Kajaria,Jhonson, Nitco, Somani, Bell, Asian or Euro make in
flooring,treads of steps & Landing laid on bed of 20 mm (Average)
base of cement mortar 1:6 (1 Cement : 6 Coarse sand) on new
34 surface or fixing on existing flooring by adhesive material including
dismentaling of existing flooring and jointed with colour cement
slurry including finished with flush pointing & cleaning the surface
etc. comp.Size 24" x 24" For Antiskid tiles
Ground Floor 38.00 S.M 1397.83
Terrace Floor 0.00 S.M 1397.83
(SOR SMC Pg No.4 It No. 43)
Providing and laying polished Kota stone slab flooring over 20mm
(Average) thick base of cement mortar 1:6 (1-cement : 6-coarse
sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and
35 jointed with grey cement slurry mixed with pigment to match the
shade of slab including rubbing and polishing etc. complete. (A)
Ground Floor 0.00 S.M 989.45
Terrace Floor 0.00 S.M 989.45
(SOR SMC Pg No.4 It No. 32)
Providing and laying polished Kota stone slab 25mm thick in risers
of steps,skirting Dedo and pillars laid on 10mm thick cement
mortar 1:3 (1-cement : 3-coarse sand) and jointed with gray
cement slury mixed with pigment to match the shade of slab
including rubbing and polishing etc. complete.
Ground Floor 0.00 S.M 1076.94
Terrace Floor 0.00 S.M 1076.94
(SOR SMC Pg No.4 It No. 33)
Supplying Fixing High Performance Sports Multipurpose Flooring
of thickness from 4 MM up to 10 MM having UV coating, durable
wear layer, Reinforced fibreglass layer, Closed cell foam backing.
Floor which Absorbs impacts from jumps and protects the joints
and muscles involved making more exercise a more comfortable
with enjoyment, having excellent power return enables patients to
increase their performance maintaining super vertical stability.
Low indentation properties you can put heavy things on it without
indentation, Environmental friendly, non-toxic, Recycled,
non-pollution, Moderate and adjusted hardness, Excellent
37 resilience, wear well, Soft, anti-slip, anti-fatigue, Convenient
installation and easy maintenance made of 85% black rubber
granules and 15% synthetic EPDM granules Density (kg/m3):
1000/1200, Hardness (Shore a):68,Stretch (MPA) :2.2, Abrasion
resistance: 0.0075g (ASTM - D4060 - 01), Rebound resistance:
55%,Friction coefficient: trends μs: 0.995, trends μk: 0.930, Shape
deformation: 42%
Ground Floor 169.00 S.M 1345.00
SMC APPROVED RATE (FIRE STATION FP-26, TP-91 SOUTH
DESCRIPTION Qty. UNIT AMOUNT
Providing and constructing sandwitch type Granite stone platform
0.6 mt. wide & 0.75 mt. height, including one end side granite stone
(Double Polish) of 1.25 mt. height & front granite stone patti of
cm wide, vertical partitions of half B.M. wall in C.M. 1:4 and 10mm
th. plaster in 1:3 with finishing smooth with cement slurry as
required and Stainless Steel sink of 0.45 mt x 0.45 mt size of
approved quality and make with required all fitings & fixitures etc.
comp as per instruction given by site in charge at all floors. (Basic
rate of Granite Rs.1,200.00 / S.M.)
All Floor 3.00 R.M. 3128.00
(SOR SMC,Pg No.11, It No. 123) MR
Providing and filling in depressions of Bath and W.C. At all floor
levels, after completing plumbing work of pans, pipes,traps etc.with
39 cinder or fly ash as directed by Engineer in charge etc. comp.For all
All Floor 43.00 S.M 500.00
(SMC SOR,Pg No.6, It No. 61) MR
Providing & fixing 35mm.th. Indian teak wood shutters for
doors, windows &clearstory windows incl. Indian teak wood
40 frames of finished size 12cm x7cm.incl. anodized aluminum
fixtures & fastenings incl. Primer coat of approved quality & two
coats of oil painting etc. For all Floor (A) Fully Panelled
All Floor 24.00 S.M 5533.68
(SOR SMC Pg No.5 It No. 53)
Providing and fixing FRP frame size 125x65 mm and 35 mm
thick FRP shutter with wood grain raised panneled design
finish shutter having extra reinforcement on sides & edges in Gel
coat finish. The core of the shutter & frame is to filed up with
injected polyurethane foam done in situ along with embedded
41 wooden pieces for stiffening & also taking hinges & fintures. The 21.00 S.M
whole FRP frame & shutter is to be water proof weather proof,
termite proof & resistance to mild acid/alkali. Rates are to be
inclusive of S.S. hinges with fastener sleeve & alluminium fixtures &
fasteningsFor all Floors.
(SMC SOR,Pg No.5, It No. 55)
Providing & fixing 35mm.th. Flush Door Solid Double Core type
Both Face water proof Ply Vennered & 1.5 mm th.laminate shall
be pasted on both side with adhesives as specified by the
manufacturers. The laminate shall be as per approved shade &
texture, of make incl. Sal wood frames of finished size 12cm x
7cm.incl. S.S. Hinges with nessary screws & Anodized aluminum
fixtures & fastenings For all Floor
(SOR SMC Pg No.5 It No. 51) MR
Same as Above But Without Frame
All Floor 17.00 S.M 2520.00
(SOR SMC Pg No.5 It No. 52) MR
DESCRIPTION Qty. UNIT AMOUNT
Providing and fixing window having extruded aluminium colour
anodized section frame main outer size 63.50 x 38.10 x1.95 mm (of
Jindal section no.4605, @ Wt. 1.094Kg/mt) horizontal Two track
member size 61.85 mm x 31.75 mm x 1.20 mm (of jindal section
no:8687, @ Wt. 0.695 Kg/mt.) vertical member of size 61.85 mm x
31.75 mm x 130 mm (of jindal section no:8758 @ wt. of
kg/mt) with sliding shutters of horizontal member size 40 mm x18
mm x 1.29 mm ( of jindal section no:8949, @ Wt. of .456 Kg/mt)
vertical member of size 40 mm x 18 mm x 1.29 mm (of jindal
section no:8947, @ Wt. of 0.456 Kg/mt/section 8948, @ Wt. of
0.457 Kg/mt) with 5 mm thick tranparent bronze colour tineted
float glass with powder coated aluminium fittings and fixtures and
transparent silicon sealant glass fixing to frame as per details etc.
complete for window.For all Floors.
(A) Same as above but colour anodized 6.00 S.M 1705.67
SMC SOR Alluminium Work ITEM NO.3(A),Pg No.17
Providing and fixing window having extruded aluminium
POWEDER COATED section frame main outer size 95 mm x 24 mm
x 1.17 mm (of jindal section no:2459 @ Wt. of 0.738 Kg/mt),
horizontal Three track member size 92 mm x 31.75 mm x 1.30 mm
(of jindal section no;8688, @ Wt. 1.07 Kg/mt), vertical member of
size 92 mm x 31.75 mm x 1.50 mm (of jindal section no:8933, @
Wt. 1.06 Kg/mt) with sliding shutters of horizontal member size
44 mm x 18 mm x 1.29 mm (of jindal section no:8947 @ wt. of 0.456 0.00 S.M
kg/mt), vertical member of size 40 mm x 18 mm x 1.29 mm (of
jindal section no:8949 @ wt. of 0.456 kg/mt) with 5 mm thick
transparent bronze colour tinted float glass with powder coated
aluminium fittings & fixtures and transparent silicon sealant glass
fixing to frame as per details etc.
(A) Same as above but colour anodized
All Floor 72.00 S.M 1591.87
SMC SOR Alluminium Work ITEM NO.2(A),Pg No.17
Providing and fixing standared extruded ofalluminium section of
size 63mm x 38.10mm x1.2mm , @ Wt. 0.643 Kg/mt with colour
45 Powder Coated alluminium frame for ventilation with 5 mm thick 0.00 S.M
frosted glass as details etc complete for Ventilation
A) Same as above but Colour anodized 3.00 S.M 2414.00
SMC SOR Alluminium Work ITEM NO.4A,Pg No.17 MR
Providing & laying granite slab 18 mm thick in Window-Door
seal,Frames Etc laid on 10 mm thick cement mortar 1:4 (1
Cement: 4 Coarse sand) with necessary adhesive material and
finished with flush pointing in white or colour cement, including
rubbing & polishing comp. (Basic Rate: Rs. 1000.00/S.M.).For all
For all Floors. 156.00 S.M 2026.00
SMC SOR , PAGE No.4 ITEM NO.41 MR
47 Labour Charges For Edge Finished For Granite for all floors
For all Floors. 2018.00 R.M 43.43
SMC SOR, PAGE No.4 ITEM NO.42
Providing & fixing M.S.Grills of required pattern to wooden frames
of windows etc. At all floor levels with M.S. flats at required spacing
& frame around square or round bars with round headed bolts &
round headed bolts and nuts or by screws incl. Priming coat of Red
lead paint etc. comp. (A) Plain grill For all Floors
(A) Plain grill
DESCRIPTION Qty. UNIT AMOUNT
For all Floors. 1998.00 Kg. 104.20
SMC SOR, PAGE NO 5 IT NO
Painting two coat (excluding priming coat) on new steel and other
metal surface with synthetic enemal paint, burshing to give an even
49 shade including cleaning the surface of all dirt, dust and other
foreign matters. (A) For plain grill For all Floor
For all Floors 97.00 S.M 65.31
SMC SOR, colour works,item no.-8,Pg No.15
Providing and fixing stainless steel ( Grade 304) railing made of
Hollow tubes, channels, plates etc., including welding, grinding,
buffing, polishing and making curvature (wherever required) and
fitting the same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary accessories &
stainless steel dash fasteners , stainless steel bolts etc., of required
size, on the top of the floor or the side of waist slab with suitable
arrangement as per approval of Engineer-incharge, (for payment
purpose only weight of stainless steel members shall be considered
excluding fixing accessories such as nuts, bolts, fasteners etc.)
SMC SOR, ITEM NO 120,Pg No.11, MR 208.00 Kg. 450.00
(1) The whole work is to be executed through specialized agency
51 with a guarantee of 10 (Ten) years given on a prescribed proforma
duly stamped (2) The rate shall include for work at all floors &
B) Providing and laying integral cement based water proofing
treatment including preparation of surface as required for
treatment of roofs, balconies, terraces etc. consisting of following
operations. (a) Applying and grouting a slurry coat of neat cement
using 2.75 kg/sqm of cement admixed with proprietary water
proofing compound comforming to IS:2645 over the R.C.C. slab
including cleaning the surface before tratment.(b) Laying cement
concrete using broken bricks/brick bats 25 mm to 100 mm size
with 50% of cement mortar 1:5 (1 Cement : 5 Coarse sand)
admixed with proprietary water proofing compound conforming to
IS:2645 ,brick bats is finally covered by jointless cement plaster
20mm th. in C.M. 1:4 added with special water proofing compound
confirming to IS:2645 & top smooth finished with trowel with false
chequered marking of 300 mm.size.The treatment is carried along
the vertical surface of the parapet & other adjoining wall up to
height of about 300 mm in a shape of quarter round vata Incl.
curing etc. Comp. With average thickness of 120 mm and minimum
thickness at khurra as 65 mm.
(c) The whole terrace so finished shall be flooded with water for a
minimum period of two weeks for curing and for final test. All
above operations to be down in order and as directed and specified
by the engineer-in-charge. With average thickness of 120 mm and
minimum thickness at khurra as 65 mm. (Cement consumption
0.511 Bags / S.M.)
Terrace and staircabin top 685.00 S.M 511.00
SMC SOR, PAGE NO 6 IT NO 62 B M.R.
DESCRIPTION Qty. UNIT AMOUNT
(A) Providing and laying water proofing treatment to vertical and
horizontal surfaces of depressed portions of W.C.,kitchen and the
like consisting of :
(a) I course of applying cement slurry @ 4.4 kg/sqm mixed with
water proofing compound conforming to IS : 2645 in recommended
(b) II course of a layer of plaster in C.M. 1:3 with water proofing
compound confirming to IS:2645 about 25 mm. th' in the floor of
the depression & about 18mm th' On the side walls of the
depression up to the floor level, water proofing plaster about
mm. th' be continued on the walls above the floor level for a height
of 600 mm. with surface suitable to receive further treatment
(c) Finishing top with stone aggregate 10mm to 12mm nominal
size spreading @0.008 C.M./S.M., thoroughly embedad in plaster
layer. as per specifications & instructions of Engineer in charge
(Cement consumption 0.316 Bags / S.M.)
For all Floors 0.00 S.M 296.00
SMC SOR, PAGE NO 6,IT NO 62 B M.R.
Providing and laying broken china mosaic flooring for terrace
using 12 mm to 20 mm broken pieces of glased tiles of to be laid
over cementr morter 1:3 to plain or slope and to be tempered to
52 bring morter crème out up to surface using white cement including
grounding off jnctions and extending them up to 15 cm along the
wall, clearing with water and oxalic acid etc as directed.
SMC SOR, PAGE NO 12 IT NO 131 685.00 S.M 747.29
Apply two coats of putty and two coats of primer of approved
brand and manufacture on new wall surface to give an even shade
53 including thoroughly brushing the surface free from mortar
dropping and other matter and sand papered smooth.
(A) for wall and similar surfaces
For all Floors 1648.00 S.M 40.59
(B) for ceilings and soffits
For all Floors 673.00 S.M 40.59
SMC SOR ,coiour works,Pg No.15,item no.-4
Wall painting (two coats) with plastic emulsion paint of approved
brand and manufacture on undecorated wall surface to give an
54 even shade including throughly brushing the surface free from
mortar droppings and other foreign matter and sand papered
(A) for wall and similar surfaces
For all Floors 1648.00 S.M 79.39
(B) for ceilings and soffits
For all Floors 673.00 S.M 79.39
SMC SOR , coiour works,Pg No.15,item no.-5
DESCRIPTION Qty. UNIT AMOUNT
Providing & applying two coats of weather shield max paint (3
coats may be required in case of darker colours.)of ICI Dulux or
Apex Ultima of Asian Paint including applying exterior acrylic
primer coat as per manufacturers specification and directions in
shade and colour approved by architects, on exterior surfaces of
the building including scaffolding, preparing the surface, watering,
curing etc. complete and as directed by the architects and
Surface Preparation : surface is thoroughly clean, dry and free
from all loose dirt, chalk, grease, fungi, algae and flaking paint. This
can be achieved by brushing with a wire/ stiff coir brush, followed
55 by water jetting if required. Fill up all minor cracks and defects
with white cement and sand mixture in the ratio 1:3. For
application on previously painted wall, previous coatings of paint
must be thoroughly scraped off and Clean the surface thoroughly
using wire brushes. Priming: Apply a liberal coat of exterior acrylic
primer and allow it to dry for 4-5 hours. Application of putty is not
recommended. Minimum 4-6 hours duration is required between
each coat of weather shield max paint.For all Floors.
For all Floors 959.00 S.M 82.00
SMC SOR, coiour works,Pg No.16,item no.-17
Providing and applying textured plaster as per design of ICI Dulux
or of Asian paint as per manufacturers specification and directions
in shade and colour approved by architects, on exterior surfaces of
the building including scaffolding, preparing the surface, watering,
curing etc. complete and as directed by the architects and
Providing & laying granite slab 18mm thick in flooring, treads of
steps and landing laid on bed of 20mm thick cement mortar 1:6 (1
Cement : 6 coarse sand) or lime mortar 1:1.5 laid and finished with
57 flush pointing in white or colour cement including rubbing and
polishing complete. (Basic Rate:- Rs.1347.46/S.M.)
For all Floors. 30.00 S.M 2410.00
SMC SOR PAGE NO 4,IT NO 39 M.R.
Providing & laying granite slab 18mm thick in skirting, risers of
steps,dedo and pillars laid on 10mm thick cement mortar 1:4 (1
58 Cement : 4 Coarse sand) and finished with flush pointing in white
or colour cement including rubbing & polishing comp.. (Basic Rate:-
SMC SOR PAGE NO 4,IT NO 40 M.R. 22.00 S.M 2449.00
Providing and fixing M.S. Fan clamps type 1 to 16 mm dia M.S. bar
bent to shpe with hooked ends to RCC slabs curing, layig including
painting the exposed portion of loops, all as per standard design
For all Floors. 15.00 Nos 129.02
SMC SOR , PAGE NO 5, IT NO
Steel work welded in built up sections, framed work including
cutting, hoisting, fixing in position and applying a priming coat of
60 (A) in beams & joists channels angles, tees, flats with connection
plates or angle cleats as in main & cross beams,hip & trussed
purlins connected to common raffers & the like. For all Floor
For all Floors. 36.63 Qtl. 9047.86
SMC SOR ,Pg No.9,IT NO 98(A)
DESCRIPTION Qty. UNIT AMOUNT
Providing & Fixing Polycarbonate sheet roofing with surface of
the sheet is coated with an anti-UV Co-extrusion layer having good
weather resistance, it can maintain its optical properties and
mechanical performance for a long time. Fasting is usually done by
screws. , The fastening screws should beinserted about 500 mm
apart and 300mm apart Along the supporting internal purlin and
61 edge pulin.All fixing holes with diameter at least 2 mm larger than
screw must be predrilled into each screw location. The screws
should be 6mm diameter with length according to sheet thickness
and corrosion resistant, with at least heavy duty hot dripped
galvanized or stainless steel. Excluding the cost of purlins rafter
(b) 2 mm thick Solid Sheet 99.00 S.M 1510.00
Extra for additional height of proping and centering where the
height of proping and centering exceed 4.0M between supprting
floor to ceilng including temporary brick or stone pillars for
suporting as required
1) height more than 4.0M and upto 5.0M 0.00 S.M 390.34
2) height more than 5.0M and upto 6.0M 0.00 S.M 688.83
R&B SOR, Pg No.75 ,Item no.-09002AA/09002BA
Providing & fixing in position collapsible steel shutters with
vertical channels 20 x10 x 2 mm. Braced with flat iron diagonals
x5mm size with top & bottom rails of T-iron 40x40x6mm. with
38mm dia. steel pulleys comp. with bolts, locking arrangements,
stoppers, handles incl. applying a priming coat of Redlead paint
Ground Floor 17.00 S.M 5865.10
SMC SOR , PAGE NO 5, IT NO
Masonary work using AAC Block Aerated light weight concrete
block having crushing strength not less than 35 kg/sqcm for super
64 structure above plinth level upto floor two level in cement
mortar 1:5 ( 1 cement : 5fine sand ) complete as per Technical
Ground Floor ( 1ST SLAB ) 0.00 C.M 4854.12
(LIBRARY & RECREATION CENTER AT P.T.P.S. NO.
(KATARGAM), F.P.NO 133, IT:31 SCDUAL B )
Providing & fixing at all floor levels,both face polished machine
cut edge Marble slab for Shelve joined with grey/White cement
slurry (1:1) incl. Rubbing & polishing etc. complete. (M.R.) (Basic
Cost Rs. 450/S.M.)
SMC SOR, PAGE NO.7,IT NO 66 (MR) 15.00 S.M 1050.00
Providing, fixing, fitting S.S. Latter of quality SS 304 or with
colour powder coating incliuding Necessary fixture & Fastaning
66 300.00 R.inch
with scaffolding etc. complete. As per requirement & Direction of
Engineer in Charge.
RATE as Per EZ_B bord and S.S logo Samati for TPS NO.22 , F.P.
NO.76 (SARTHANA) incd GTS ITEM
Providing, Approving designing and supplying 6mm thick white
Acrylic computer Laser cutting Latter including necessary
67 300.00 R.inch
scaffolding, pasting on ACP sheet or similar surfaces, etc. complete.
RATE as Per EZ_B bord and S.S logo Samati for TPS NO.22 , F.P.
NO.76 (SARTHANA) incd GTS ITEM
68 Wall Vinyl Sticker 44.00 SQ. FT. 28.00
SMC SOR, PAGE NO.13,IT NO 146 (MR)
Eco Solvent Vinyl Sticker (120 gsm) with Lamination (100 gsm)
SMC SOR, PAGE NO.13,IT NO 147 (MR)
70 Solvent Vinyl Sticker (120 gsm) with Lamination (100 gsm) 44.00 SQ. FT. 22.00
SMC SOR, PAGE NO.13,IT NO 148 (MR)
71 5mm PVC sheet Eco Vinyl (Any size) 44.00 SQ. FT. 55.46
SMC SOR, PAGE NO.13,IT NO 149 (MR)
DESCRIPTION Qty. UNIT AMOUNT
Decorative theme base designing & painting with all waterproof
SMC SOR, PAGE NO.13,IT NO 150 (MR)
WATER SUPPLY & SANITATION
Prov.& Fixing water closet squatting pan (Orissa type W.C.pan) at
all floor levels, size 500mm x 400 mm incl. 100 mm size "P'or "S"
73 trap for water closet squatting pan joining the trap with the pan &
soil pipe in C.M. 1:1 (1cement :1 fine sand) etc. Comp.(A) Vitreous
china long pattern
Make- Cera S3010109, Parry ware C0117CS/C0117* , Jaquar
For all Floors. 1.00 Nos. 3275.00
SMC sor- Sanitary Items, Page no22, It No.
Providing and fixing Wash Down Water closet European type W.C.
pan with integral P or S trap with normal closing seat cover L bend
74 ncluding jointing the trap with soil pipe in cement mortar 1:1 (1
cement : 1 find sand) (A) Viterous china pattern - I
Make- Cera CONVENTIONAL B1510121 , Parry ware C0297*/
C0278, HindWare sleek 20011, Jaquar- CNS-WHT-751P180SPPZ
For all Floors. 7.00 Nos 3282.00
SMC sor- Sanitary Items,Page no21,It No.
Prov.& Fixing Health Faucet ABS Body with wall Hook and 1 Meter
chrome plated PVC Hose Pipe
Make- Cera F8030106AB, Parry ware T9874A1, Jaquar ALD-587
,HindWare F160109
For all Floors. 7.00 Nos 971.00
SMC sor- Sanitary Items, Page no22, It No.
Providing Metropole Flush Valve Dual Flow 40mm
76 Size (Concealed Body)
Make- Cera F8010202 , Parry ware T3302A1 , Jaquar FLV-1089NSQ
,HindWare F860075
For all Floors.
SMC sor- Sanitary Items, Page no22, It No.
Providing & fixing Wash Hung basin with single hole for pillar tap
, Size- 550 x 400 mm at all floor levels, with C.I. or M.S. Brackets
painted white incl. cutting holes & making good the same etc.
complete. For all Floor
Make- Cera Cat. No. S2040121, Parry wareC0434* (CTH), Jaquar
SLS- WHT -6801 ,HindWare10004
For all Floors. 5.00 Nos 2656.00
SMC sor- Sanitary Items, Page no21, It No.7
Providing & fixing 600 mm.x 450 mm. mirror of superior glass
at all floor levels, mounted on 6 mm. th. A.C. sheet or plywood
sheet & fixed to wooden plugs with C.P.brass screws and washers
etc. For all Floor
All Floor 5.00 Nos 833.73
SMC sor Page no7 , It No.72
Providing & fixing C.P. brass pillar cock with copper connection,
C.P. brass screws complete
Make- Cera F2013101, Parry ware Cat. No.: G3102A1, HindWare
Cat. No.: F650003, Jaquar FLR-5011N
For all Floors. 5.00 Nos 1423.00
SMC sor Sanitary Items,Page no21, It No.
Providing & Fixing 15 mm Dia bib tap with wall Flange at all floor
levels, polished bright etc. comp
Make- Cera F2013151 BIB COCK, Parry wareG3104A1, HindWare
F280002 BIB COCK, Jaquar FLR-5047 N BIB COCK 24.00 NO
DESCRIPTION Qty. UNIT AMOUNT
SMC sor Sanitary Items,Page no21, It No.
Providing & Fixing 15 mm Dia 2 way bib tap with wall Flange at all
floor levels, polished bright etc. comp
Make- Cera F2013163, Parry ware G4834A1, HindWare Cat. No.:
F530004, Jaquar FLR-5041N
SMC sor Sanitary Items,Page no21, It No.
Providing flush cock consisting lever, cartridge sleeve & flange &
Make- Cera EXPOSED PART F2013751 &Concealed part F4060101
Parry ware T9824A1&T9823A1, Jaquar FLR 5083 KN , CONCEALED
BODY ALD-081,HindWare F280052 & CONCEALED STOP COCK
All floor 7.00 NO 2110.00
SMC sor Sanitary Items,Page no21, It No.
Providing & fixing 15mm C.P. brass angle valve (Stop Cock) with
C.P. copper connecting pipe 450 mm long and nuts, washer and
83 brass flange complete, including cutting and making good the wall
where required.
Make- Cera F1020362, Parry ware T0712A1, HindWare Cat. No.:
F440020 F850094, jaquar CON 053 KN
For all Floors. 5.00 Nos 1432.00
SMC sor- Sanitary Items,Page no21,It No.
Providing and fixing Towel Ring fabricated from seamless
stainless steel tube 2mm thick in bath room with polished wall
flange at end of bars with heavy duty anchor fasteners &
Make- Cera F5014115CH, Parry ware F5014115CH, Jaqua ACN
1121N ,HindWare F880007
For all Floors. 5.00 Nos 890.00
SMC sor Sanitary Items,Page no21,It No.
Providing & Fixing stainless steel recessed type Soap dish of
85 approved make. Including providing & fixing screws, washers,
cutting & making good the walls.
Make- Cera F5007106, Parry ware T6902A1, Jaquar ACN-
1131N,HindWare F880011
For all Floors. 5.00 Nos 793.00
SMC sor Sanitary Items,Page no21,It No.
Providing and fixing PVC SWR Nahni trap IS 14735 for drain -
mm diameter with jali of the following nominal diameter of self
86 cleaning design with C.I. scread down or hinged grating including
the cost of cutting and making good the walls.
All floor 15.00 No. 558.36
SMC sor.Page no 8,It No.
Providing & Fixing U-PVC pipe (SWR) confirming to IS no.
(Type"B") of Prince/ Supreme/ Jain/ Astral/ Tulsi/ Finolex make
87 for soil and waste discharge system at all floor levels incl. All
fixtures like bends, tees,shoe etc. jointed with resin of approved
brand & manufacture etc. comp.(M.R.)
SMC sor,Page no 8 It No. 84 M.R.
Providing & fixing U-PVC pipes Confirming to IS no. 13592 (Type
"A") of Prince/ Supreme/ Jain/ Astral/ Tulsi/ Finolex make for rain
88 water at all floor levels incl. fixtures like bends, tees, shoe etc
joined with resin of approved brand & manufacture etc. comp.
(M.R.) (A) 75 mm. Dia.
DESCRIPTION Qty. UNIT AMOUNT
SMC sor ,Page no 8, It No. 85 M.R.
Providing and fixing in position P.V.C. cowl vent to pipes of prince,
suprime, jain Or Eqivalent make etc. comp (M.R).
SMC sor- Page no.8, It No.
Providing & Fixing Kathi around the vertical PVC drainage pipes for
concealing with cement plaster 20 mm avg thickness(CM 1:3 [1
90 cement :3 coarse sand]) finishing as per instruction given by Eng.
75mm PVC pipe 60.00 R.M 173.00
SMC sor- Page no.8, It No. 93 MR
Providing, Laying and jointing on true line and level UPVC pipe
(SCH-40) line of prince/Supreme/Jain/Astral/ Tulsi/Finolex make
including fittings make or equivalent as approved by angineer-in-
charge. Pipe shall be fixed on the wall the help of clamp at every
two meter C/C or shall be concealed as directed including
necessary fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all materials.
SMC sor Page no 8 It No.
Providing & Fixing P.V.C. pipes (SCH-80) of Prince/ Supreme/
Jain/ Astral/ Tulsi/Finolex make for water supply line at all floor
levels incl. fixtures like bends, tees, shoe etc joined with resin of
approved brand & manufacture etc. comp. Pipe shall be fixed on the
92 wall the help of clamp at every two meter C/C or shall be concealed
as directed including necessary fittings etc. including testing of
pipe and joints and fixing the same with adhesive solvent, including
cost of all materials.
SMC sor Page no8 It No. 87 MR
Providing and fixing M.S. holder bat clamps at all floor level,of
93 approved design to C.I. or S.C.I pipes including cost of cutting holes
and making good the wall etc. comp. (M.R)
SMC sor- Page no8, It No. 90 MR
Providing and fixing G.I. holder "Z" clamps at all floor level,of
94 approved pipes including cost of cutting holes and making good the
wall etc. comp. (M.R)
(C) 150 mm to 200 mm dia 0.00 NO 98.00
SMC sor- Page no 11, It No. 121 M.R.
Providing and fixing gun metal check or non return full way wheel
valve at floor levels,etc. complete.
SMC sor Page no8,It No.
Providing and fixing abonite ball cock of approved quality as
directed etc. comp.
SMC sor- Page no 8,It No.
DESCRIPTION Qty. UNIT AMOUNT
Providing, Lowering and laying joining R.C.C. NP2 CLASS pipe in
cement mortar in proportion 1:1 of following nominal internal
diameters including testing of pipes and joints etc. complete.
SMC sor- Page no.7, It No.
SMC Storm drainage SOR 22-23, Page no1 It No.1
Providing and fixing s.w. Gully trap with C.I. gratting brick
masonary chamber and water tight Pre cast R.C.C.cover of 300mm
X 300mm size (inside) including plastering smooth inside and
outside 15 mm thick in C.M 1:3 etc. comp.i) square mouth traps
(A)300 MM X 300 MM Size - P type.For all Floors.
SMC sor,Page no 7, It No.
Prov. & Fix. 10 cm.x15 cm.(4" x 6") S.W. trap with Inside
dimension ,455 x 610 mm & 450 mm deep sewer trap chamber
with 23 cm th' B.B. masonary walls in C.M 1:5 with cement plaster
15 mm th' in C.M. 1:3 inside & outside to exposed faces, R.C.C. top
99 slab with 1:2:4 mix ( 1 cement: 2 Sand : 4 Grade stone aggregate 0.00 No.
20mm size) ,Foundation concrete 1:5:10 & fixing C.I. cover with
frame to be not less than 38 kg. On top etc. comp. for single
pipe.'.(A) Precast RCC heavy duty Cover instead of C.I. Cover
(A).Same as above but Precast RCC heavy duty Cover instead of C.I.
Extra for every additional depth of 0.1 mt.beyond 0.45 mt. 0.00 Each 222.71
SMC sor, Page no.7, It No.75
Providing & construction simple chamber of 23 cm. th' B.B.
Masonary in C.M 1:5 with cement plaster 15 mm th' in C.M. 1:3
inside & outside to exposed faces, R.C.C. top slab with 1:2:4 mix (
100 cement: 2 Sand : 4 Grade stone aggregate 20mm size), Foundation 0.00 No.
concrete 1: 5: 10 & fixing C.I. cover with frame to be not less than
38 kg. On top etc. comp. Inside dimension, 455 x 610 mm &450 mm
deep for single pipe
(A).Same as above but Precast RCC heavy duty Cover instead of C.I.
Extra for every additional depth of 0.1 mt.beyond 0.45 mt. 0.00 Each 242.39
SMC sor - Page no7,It No.76
Providing and fixing C.I. Machinehole cover 0.60 x 0.45 mt. Size
having weight not less than 35 Kg. etc. complete.
SMC sor- Page no.8, It No. 83 10.00 NO 958.17
Providing and fixing G.I, Rain water spout of 50 mm dia and 30 cm
SMC sor- Page no6 It No. 64 15.00 NO 101.91
Providing & fixing white vitreous china urinal of size 450 x325mm
as per IS-2556 (Part-2 ) with C.I. hangers and 15mm dia. C.P.
103 spreader,32mm dia CP bottle trap and pipe to wall with C.P. flange
complete including cutting and making good the walls and floors
wherever required.
Make- CeraCat. No. S4020103, Parry ware C0501*, Jaquar URS-
WHT 13261H ,HindWare BACK SMALL 60001
SMC sor- Sanitary Items,Page no.21, It No.8
Providing & fixing at all floor levels,both face polished machine cut
edge Marble slab for urinal partition joined with grey/White
cement slurry (1:1) incl. Rubbing & polishing etc. complete. (M.R.)(
Basic Cost Rs. 450/S.M.)
SMC sor- Page no7 It No. 66 MR 4.00 S.M 1050.00
DESCRIPTION Qty. UNIT AMOUNT
Providing & laying ordinary C.C.1:1.5:3 mix for R.C.C. work incl.
boxing, centering, vibrating, curing & mixed with approved water
proofing cement compound or "CEMWET"or"PIDICRETE
LW"integral water proofing admixture as water proofing agent to
be mixed with 50 kg. cement bag shall be as recommended by the
manufacture of the water proofing material, concrete work for top,
bottom slab & side pardi for Under ground Tank & Item incl.
Necessary excavation & refilling the available earth, 15 cm th' C.C
105 1:4:8 for bedding concrete, Half B.M. in C.M. 1:4 outside wall, inside
R.C.C. pardi as per design, 10mm.th. water proofing cement plaster
in C.M. 1:3 with smooth finishing,watering etc.Comp.to all inner
face & bottom of tank curing etc. comp. incl. Locking arrangement,
outlet, inlet, overflow & wash out pipe arrangement as necessary &
C.I. Cover 0.60 x .045 weight not less then 35kg. etc. com. as per
structural drawing excluding Steel & as directed by Engineer-in-
Under Ground water Tank 10000.00 Lit 5.46
SMC sor - Page no6. It No.
Providing & Laying white glazed tiles 6mm. th. of Orient, Kajaria,
Jhonson, Nitco, Somani, Bell make at all floor levels, in flooring,
106 treads of steps & landings laid on a bed of 12 mm. Av. Th.C.M.1:3
(1cement : 3 sand) finished with flush pointing in white cement
etc.com. For all floors
Under Ground water Tank 31.00 SM 857.42
SMC SOR, Page no4, It No.
Providing & Laying white glazed tiles 6mm. th. Of Orient, Kajaria,
Jhonson, Nitco, Somani, Bell make at all floor levels in skirting
risers of steps & dado on 10 mm. th. C.M.1:3 (1cement :3 sand)
including necessary cement paste for fixing and joined with white
cement slurry etc.complete. For all floors
Under Ground water Tank 86.00 SM 887.64
SMC SOR, Page no4, It No.
Providing & fixing IS Mark TMT FE 500D reinforcement for R.C.C.
108 work incl. bending, binding & placing in position etc. comp. Upto
Upto G.L./P.L. 1180.00 Kg. 76.21
SMC SOR- Page no1, It No.
Providing erecting and fixing double coated Sintex/Super/Reno
PVC (ISI) mark water tank of required capacity each with all
necessary fittings & connection etc. complete on terrace.
SMC SOR- Page no 8, It No.
(A) PAVER BLOCK & VDS ROAD
Box Cutting the road surface to proper slope and camber for
making base includinng removing the excavated stuff and
depositing on the road side slope as directed up to 50 mt. lead.
SMC SOR-PAGE NO 20 IT NO GD.1
Preparation of subgrade with compacting, Leveling and
consolidation of subgrade with miniroller/plate vibrator machine
including watering and filling in depression occur the process as
directed by engineer in charge.
SMC SOR-PAGE NO 20 IT NO GD.2
DESCRIPTION Qty. UNIT AMOUNT
Providing & laying Granular Sub Base(GSB) confirming to Grading
V of Table 400.0 of compacted th. Of 150 mm with specified graded
stone metal and sand mixed in place and laid with mechanical
means spreading with motor grader and compactiong with
vibratory roller having miimum 80-100 KN static weight to achieve
desired dencity of 98 % of MDD including all material, labour,
machinery with all leads and lifts etc. comp.
SMC SOR-PAGE NO 20 IT NO GD.9
Providing & laying C.C 1:3:6 (1cement : 3 coarse sand :
4 Crushed stone agg 20m.m Nominal size) &curing comp. excl. cost 119.00 C.M.
of form work in :(a) foundation & Plinth
SMC SOR-PAGE NO 1 IT NO
providing and laying 200 micron plastic sheet on prepared sub
5 base as per instruction of Engg. In charge etc. complete. 633.00 S.M.
SMC SOR-PAGE NO 20 IT NO GD.12 MR
Supplying & filling fine sand (pana) in 75 mm /100 mm /
150mm compacted thickness over the base including necessary
6 compaction, watering etc. compacted. Item includes levelling by 104.00 C.M.
using vibratory plates compacted machine and as directed by
engineer in charge.
SMC SOR-PAGE NO 20 IT NO GD.4
Providing 100mm th. Ready made C.C. kerb of strength M-20 (Size
300mm X 380mm) purchased from SMC's approved paverblock
manufacturer & setting in line level and in truly vertical postion,
including filling joints in C.M. 1:1 (1 part of cement : 1 part of stone
dust ) smooth pointing in C.M. 1:1 ( 1 part of cement : 1 part of
coarse sand) including watering etc. complete and as directed by
engineer in charge.
SMC SOR-PAGE NO 20 IT NO GD.6 MR
Providing interlocking type Rubber moulding cement concrete
Paver Block of approved shape, design & colour having 60 mm
thickness (M-35) Purchased from S.M.C's approved paverblock
manufactures only & fixing on fine sand bedding. Item includes
leveling by using vibratory plates compacted machine. Item also
includes all materials, labour, equipments, tools, plants, watering,
cleaning etc. Complete
With colour 380.00 S.M. 524.00
Without colour 380.00 S.M. 524.00
SMC SOR-PAGE NO 20 IT NO GD.7 MR
Providing & filling with Mix soil in layers of 20 cm. Th'. Incl.
watering, ramming & consolidation etc. complete.
SMC SOR-PAGE NO 20 IT NO GD.3
Providing & filling in plinth with murrum or selected soil in layers
10 of 20 cm. Th'. Incl. watering, ramming & consolidation etc. 2024.00 C.M.
SMC SOR-PAGE NO 1 IT NO
Providing & laying cement concrete Pavement using 1:1.5:3 (1
cement:1.5 sand:3 graded stone agg. 20 mm nominal size) &
Vaccuum Dewatering technique including floating surface with a
skim powder floater, curing etc. complete.
Internal road 79.00 C.M. 5981.00
SMC SOR-PAGE NO 20 IT NO GD.10
Cutting of Groove 5.00 to 7.00 mm th. In VDS for depth of 1/3 of
12 total thickness with filling of epoxy sealent as directed by engineer 350.00 R.MT
SMC SOR-PAGE NO 20 IT NO GD.13
Providing & fixing IS Mark TMT Bar FE 500D reinforcement for
13 R.C.C. work incl. bending, binding & placing in position etc. comp.
DESCRIPTION Qty. UNIT AMOUNT
Upto G.L./P.L. 3160.00 Kg. 76.21
SMC SOR-PAGE NO 1 IT NO
(B) COMPOUND WALL & MAIN GATE
Boring holes 3.5 mt.deep in ordinary soil ( for cast in situ piles) &
disposal of the surplus excavated soil as directed within a lead of
50 M. For following diameter of piles.
for 250 mm dia 282.00 R.M 326.84
for 300 mm dia 69.00 R.M 391.74
SMC SOR-PAGE NO 9 IT NO
Excavation for foundation includ.sorting out & stacking of useful
materials & disposing of the excavated stuff upto 50 mt. Lead & all
lift, watering etc. Comp. (A) Loose or Soft soil
Executed With Mechanised Efforts / Machinaries
( 1 ) up to 1.5 mt. Depth 42.00 C.M. 117.26
SMC SOR-PAGE NO 1 IT NO
Providing & laying cement concrete 1:4:8 (1 cement:4 coarse
3 sand:8 gradedstone agg. 40 mm nominal size) & curing comp.
excl.cost of form work in
(A) Foundation and plinth 9.00 C.M. 2680.21
SMC SOR-PAGE NO 1 IT NO
Providing & laying cement concrete 1:1.5:3 (1 cement:1.5 sand:3
graded stone agg. 20 mm nominal size)& curing comp. Includ.cost
of form work but exclu. Cost of reinforcement for reinforced
concrete work in
(A) foundation, footing, base of columns and mass concrete
SMC SOR-PAGE NO 1 IT NO
Providing & laying ordinary cement con.1:1.5:3 (1cement:1.5sand:
3 graded stone agg. 20 mm nominal size) finishing smooth curing
etc. comp. Incld. Cost of form work but excl. Cost of reinforcement
for R.C.C. Work in
( B ) Ground Beam:
(1)Having c/s area up to 0.08s.mt
upto G.L./P.L. 26.00 C.M. 9102.61
(2) Having cross sectional area 0.08 to 0.12 sq. mt .
upto G.L./P.L. 0.00 C.M. 8174.41
SMC SOR-PAGE NO 1 IT NO
Providing & laying ordinary cement con.1:1.5:3 (1cement:1.5sand:
3 graded stone agg. 20 mm nominal size) finishing smooth curing
etc. comp. Incld. Cost of form work but excl. Cost of reinforcement
for R.C.C. Work in
(1) Having c/s area up to 0.08 sq.mt. 0.00 C.M. 12632.60
SMC SOR-PAGE NO 1 IT NO
Providing & laying C.C. 1:3:6 (1 cement : 3 sand : 6 stone agg.
7 mm nominal size) & curing complete including cost of formwork in 11.00 C.M.
wall caps & copping.
SMC SOR-PAGE NO 9 IT NO
Filling available excavated earth (excluding rock) in trenches.
plinth, sides of foundations etc. in layers not exceeding 20 cm. in
8 depth consolidating each disposited layer by ramming and 43.00 C.M.
SMC SOR-PAGE NO 1 IT NO
Providing & fixing IS Mark TMT Bar FE 500D reinforcement for
R.C.C. workincl. bending, binding & placing in position etc. comp.
Upto G.L./P.L. 6630.00 Kg. 76.21
SMC SOR-PAGE NO 1 IT NO
DESCRIPTION Qty. UNIT AMOUNT
Providing & laying ordinary cement con.1:1.5:3 (1cement:1.5sand:
3 graded stone agg. 20 mm nominal size) finishing smooth curing
etc. comp. Incld. Cost of form work but excl. Cost of reinforcement
for R.C.C. Work in : Up to G.L./P.L.
(1)Having c/s area up to 0.08 s.mt 20.00 C.M 12632.60
(2) Having c/s area more than 0.08 sq. mt. & upto 0.12 sq.mt
(1)Having c/s area up to 0.08 s.mt 0.00 C.M 9102.61
(2) Having c/s area more than 0.08 sq. mt. & upto 0.12 sq.mt
SMC SOR-PAGE NO 1 IT NO
Providing & fixing IS Mark TMT Bar FE 500D reinforcement for
R.C.C. workincl. bending, binding & placing in position etc. comp.
Upto G.L./P.L. 4200.00 Kg. 76.21
SMC SOR-PAGE NO 1 IT NO
Brick work using common burnt clay building bricks having
crushing strengthnot less than 35 kg./Sq.Cm. in Cement Mortar 1:6
(1- Cement : 6 -fine sand)(C) Fly Ash Bricks
At ground floor 158.00 C.M. 4511.97
SMC SOR-PAGE NO 2 IT NO
Half brick masonry in common brunt clay building bricks having
crushingstrength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4
13 (1- Cement : 4 -coarse sand ) in foundation and plinth (C)Fly Ash
At ground floor 0.00 S.M. 625.53
SMC SOR-PAGE NO 2 IT NO
Providing & Applying 10mm.th.cement plaster in single coat on
brick/concrete walls similar surfaces for plastering & finished even
14 & smooth with afloating coat of cement slurry mixed with
admixture of lime or neeru inrequired proportion etc. comp. in C.M
1:3 (1 cement : 3sand)
(A) For wall and similar surfaces
At Ground Floor 0.00 S.M. 189.79
(B) For ceilings & soffits
At Ground Floor 0.00 S.M. 214.60
SMC SOR-PAGE NO 3 IT NO
20mm thick sand faced cement plaster on walls for height more
than 10 metres above ground level consisting of 12mm thick
15 backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick
finishing coat of C.M. 1:1 (1-cement : 1-
sand) etc. complete.
At Ground Floor 1462.00 S.M. 330.88
SMC SOR-PAGE NO 3 IT NO
Providing throating or plaster drip and moulding it to R.C.C.
chajja etc. comp.. For all floor
At Ground Floor 0.00 R.M. 41.66
SMC SOR-PAGE NO 3 IT NO
17 Pro. smooth plaster patta
At Ground Floor 1006.00 R.M. 27.27
Providing 20 mm deep finished groove in plaster in line and
level etc. Comp. For all Floor (M.R.)
At Ground Floor 465.00 R.M. 50.00
SMC SOR-PAGE NO 3 IT NO
DESCRIPTION Qty. UNIT AMOUNT
Providing & applying two coats of weather shield max paint (3
coats may be required in case of darker colours.)of ICI Dulux or
Apex Ultima of Asian Paint including applying exterior acrylic
primer coat as per manufacturers specification and directions in
shade and colour approved by architects, on exterior surfaces of
the building including scaffolding, preparing the surface, watering,
curing etc. complete and as directed by the architects and
Surface Preparation : surface is thoroughly clean, dry and free
from all loose dirt, chalk, grease, fungi, algae and flaking paint. This
19 can be achieved by brushing with a wire/ stiff coir brush, followed
by water jetting if required. Fill up all minor cracks and defects
with white cement and sand mixture in the ratio 1:3. For
application on previously painted wall, previous coatings of paint
must be thoroughly scraped off and Clean the surface thoroughly
using wire brushes.
Apply a liberal coat of exterior acrylic primer and allow it to dry for
4-5 hours. Application of putty is not recommended. Minimum 4-6
hours duration is required between each coat of weather shield
(A) For wall 1469.00 S.M 82.00
SMC SOR- COLOUR WORK PAGE NO 16 IT NO
M.S. Gate Steel work welded in built up sections,frame work
20 including cutting, hoisting, fixing in position and applying apriming
coat of red lead paint :-
(A) In beams and joists channels angles, tees, flats with connection
plats or angle cleats as in main and cross beams, hip and trussed
purlins connected to common raffers and the like.
Ground Floor 8.50 Qtl 9047.86
SMC SOR-PAGE NO 9 IT NO 98(A)
Providing & fixing M.S. Grills of required pattern to wooden
frames of windows etc. at all floor levels with M.S. flats at required
spacing & frame around square or round bars with round headed
bolts & round headed bolts and nuts or by screws incl. Priming coat
of Red lead paint etc. comp. (A) Plain Grill For all floors
All Floor 1264.00 KG. 104.20
SMC SOR-PAGE NO 5 IT NO
Painting two coat (excluding priming coat) on new steel and
other metal surface with synthetic enemal paint, burshing to give
22 an even shade including cleaning the surface of all dirt, dust and
other foreign matters.
Ground Floor 116.00 S.M. 65.31
SMC SOR- COLOUR WORK PAGE NO 15 IT NO
Providing and fixing hot dip Concertina Coil of 610mm dia made
out of 2.59mm (12SWG) hot dip galvanized (G.I coating not less
than 200 gm/sq.m)th. Wire having 80 nos. of spies and 200 nos. of
clips made out of stainless steel (AISI 304) 1.5 mm th. Dia, G.I.
23 Strips 0.5 mm ht. (G.I coating not less than 120 gm/sq.m ) weight of 2090.00 RMT
one coil should not be less than 15 kg etc. complete, at the top of
compound wall fixed with S.S clips and binding wires wherever
necessary etc. complete. (Note : Stretching lenght of one coil should
not be more than 9 mt.) As per Engg. In charg direction.
SMC APPROVED RATE
DESCRIPTION Qty. UNIT AMOUNT
Providing, supplying and fixing of MS angles 50X50X5 mm over
existing compound wall (for laying Concertina coil & barbed wire
fencing) as per approved design "Y" shape, drawing including
fabrication, cutting, welding, to required pattern, making holes, etc.
complete with one coat primer and two coats of synthetic enamel
paints of approved manufacture, colour, brand and shade, cost of
materials, fixtures, necessary accessories scaffolding, tools n
tackles, labours, transportation at all heights and levels as directed
24 by engineer incharge. Note 1) dismantling of existing compound 6.38 Kg.
wall of BBM/SSM for fixing of MS angles. 2) providing and laying of
M-15 grade concrete (size of concrete required up to
300x300x300mm minimum) for fixing og MS angles. (price to be
quoted inclusive of concrete works incluidng shuttering supports
and chipping along with MS angles works and carting away the
(SOR SMC It No. 98A)
(C) WATER SUPPLY & SANITARY
Providing and constructing simple chamber of 23cm. of B.B.
masonary wall in c.m. 1:5 incl. 15mm. thick cement plaster in c.m
1:3 inside and out side to exposed faces R.C.C. top slab with1:2:4
1 mix (1 cement : 2 sand : 4 grade ston aggregate 20mm size), 15.00 No
foundation concrete 1:5:10 with fixing Precast RCC. heavy duty
cover on top etc. inside dimension 455 x 610mm & 450mm deep
for single pipe
SMC SOR-PAGE NO 7 IT NO
Providing, Lowering & laying joining R.C.C NP2 CLASS pipe in C.M
2 1:1 of following nominal internal diameters incl. Testing of pipes
and joints etc. Comp
SMC SOR-PAGE NO 7 IT NO
Providing & Fixing P.V.C. pipes (SCH-80) of Prince/ Supreme/
Jain/ Astral/ Tulsi/Finolex make for water supply line at all floor
levels incl. fixtures like bends, tees, shoe etc joined with resin of
approved brand & manufacture etc. comp. Pipe shall be fixed on the
wall the help of clamp at every two meter C/C or shall be concealed
as directed including necessary fittings etc. including testing of
pipe and joints and fixing the same with adhesive solvent, including
cost of all materials.
SMC SOR-PAGE NO 8 IT NO
Providing and fixing C.P brass screw down bib tap at all floor level
polished bright etc. comp.
SMC SOR-PAGE NO 8 IT NO
Providing and fixing gun metal check or non return full way
wheel valve at floor levels,etc. complete.
SMC SOR-PAGE NO 8 IT NO
(D) RECHARGE BORE WELL (2 Nos.)
DESCRIPTION Qty. UNIT AMOUNT
Drilling 300 mm diameter borewell in all types of strata up to
required depth including cost of bentonite powder, carting rings,
cutter, other required materials, labour charges etc. complete. The
drilling shall be done by mud flushed rotary equipment and bore
holes should withstand at least till completion of subsequent
activities like assembly jointing, lowering of casing / strainer pipes,
gravels packing, yield testing etc, complete up to required depth as
shown in drawing
and directed by engineer –in- charge.
CE/HYD/01/2024-25 IT No
Supplying and filling clean best quality of well sorted - " SEVALIYA"
sorted pea gravel having size 6 mm to 10 mm in layer of required
thickness in filter chamber as per drawing and as directed by
Engineer –in- charge.
CE/HYD/01/2024-25 IT No
Providing and fitting bail plug having length 0.45mtr. from M.S
medium class pipe as per ISI for 200 mm diameter pipe.
Development of each water bearing zone come across up to the
depth of tube well (size 250 mm diameter & depth more then
4 2.00 JOB WORK
ft.) by lowering 100 mm diameter drop line and 32 mm diameter GI
air line for each Zone with air compressor of capacity not less.
Providing & Fixing MS Clamps with threaded of standard make
suitable for ERW pipes.
(a) For 200 mm Diameter ERW blank pipe with size 750 x 75mm x
10mm thick suitable for 200mm diameter.
Excavation for foundation in and all kinds of soil including leveling
and ramming the bottom of trenches and foundation pits, shoring,
6 strutting, dewatering if required, slush removing, filling the sides
up to original ground level for rectangular chamber and trench.
CE/HYD/01/2024-25 IT No
Providing and laying Cement Concrete M-100 grade 1:3:6 (1
cement: 3 coarse sand : 6 hand brocken stone aggregate 20mm
7 nominal size ) and curing complete excluding cost of form work in 1.24 C.M
chamber P.C.C(without forms work) work complete. .( S.O.R.-2023-
SOR 23-24 IT-05 PG-01
Providing & laying Fly ash Brick masonary having crushing
strength not less then 70kg/sq.cm. 1:6 (1 cement : 6 fine sand) with
scaffolding, watering, curing etc. complete with all labours and
materials.various area as directed by incharge .
SOR 23-24 IT-16 PG-02
Providing 10mm thick Cement Plaster in single coat on
brick/concrete walls far interior plastering up to Floor two level
and finished even and smooth in cement morter 1:3(1 cement
sand various area as directed by incharge) .
SOR 23-24 IT-24 PG-03
Providing, fixing M.S Jali frammed work (three piece with handle
fitting) on Opening portion Precast Module Structure for
Prevention of Recharge bore well structure,size including framme,
heavy required Angle (40 x 40 x 6mm), flat pati (25 x 6mm),cuttin
SOR 23-24 IT-98 PG-09
Providing & Supplying 200mm dia mater 1.5mm L.C.G (Low
Carbon Galvanise) 'V' wire screen pipe of Johnson or approved
11 make ISI including lowering, fixing, jointing in bore hole as per 24.00 R.M
aquifer depth and pipe assembly given as per site condition Soil
DESCRIPTION Qty. UNIT AMOUNT
Providing, Supplying, Fixing in bore hole 6Kg/cm2 P.V.C Pipe of
approved Quality (Prince,Suprem,Finolex) with ISI mark including
nesessary fittings and providing as per site sitution and directed by
Engineer –in- charge. ( 200 mm ( 8'') dia
Providing, Supplying, Fixing P.V.C. 6 Kg/Cm2 Pipe IS stanadard for
down take / inlet from Bldg./ Structure to Sand filter Chamber,
including piping/ plumbing, fitting, wall clamping, necessary
excavation and filling etc. complete as per site situation
(a) 110mm Dia.,6 Kg/Cm2 P.V.C. pipe. 7.00 R.M 325.00
(b) 160mm Dia., 6 Kg/Cm2 P.V.C. pipe. 20.00 R.M 525.00
Providing, supplying, fixing and installing M 300 Grade. precast
size 1.5 dia x 2.35 mt. height ,top 75mm thick in 2 half pieces Sand
Filteration chamber (2 layer Type of Precast module )as per
Design, Drawing.including necessary excavation, filling, dr
(a) 1 layer type of Precast module 0.00 NO. 18500.00
(b) 2 layer Type of Precast module 2.00 NO. 25000.00
Proving & fixing in position Johnson make and equivalent ... 'V'
wire L.C.G screen pipe 1.00 mm size of filter assembly of pair –ID
205mm & OD 217.50mm of 0.5mm slot size and ID 416 mm and OD
428 mm of 1.00mm slot size as per site situation
(a) 1.0 mt. length. 0.00 SET 7500.00
(b) 2.0 mt. Length. 2.00 SET 14000.00
Borehole Video photography all the fresh new fresh new bores or
16 few selected as desired for better understanding & clarity of work 2.00 JOB
undertaken as directed by Engineer -in-charge.
Supplying water tankers for constant water supply at tube well
Compressor work and cleaning of work site after completion of
entire job (testing) inluding cleaning of mud etc.Location as
directed by Engineer-in-charge.
Providing and Fixing Recharge Borewell name boards as per
standard I.R.C type design of steel plate including painting lettering
etc. complete with fixing in C.C 1:4:8 block with necessary
Soil Investigation Test report from Govt.approved authorised
laboratary (Prior inserting bore Pipe) of each bore shall be
19 2.00 EACH BORE
submitted by Contractor and soil sample of various starta shall be
first collected in Polythene bag and than submitted in transparent
Removal of surplus excavated earth of excavated mud-pits and
20 water harvesting chambers up to the lead of 5.0 km as per the 7.20 C.M
instruction of Engineer In Charge
(E) PARKING SHED, ELECTRICAL & FIRE ROOM
WORK UP TO PLINTH LEVEL
Excavation for foundation includ.sorting out & stacking of useful
materials & disposing of the excavated stuff upto 50 mt. Lead & all
lift, watering etc.Comp. (A) Loose or Soft soil
Executed With Mechanised Efforts / Machinaries
(A) Loose or soft soil
(1) Up to 1.5 Mt. depth 387.00 C.M 117.26
SMC SOR-PAGE NO 1 IT NO
DESCRIPTION Qty. UNIT AMOUNT
Providing & laying C.C 1:3:6 (1cement :3 coarse sand :6 Crushed
stone agg 20m.m Nominal size)&curing comp. excl. cost of form
work in :(a) foundation
(A) Foundation 32.00 C.M 3005.76
SMC SOR-PAGE NO 1 IT NO
providing, mixing, placing, compacting by machine vibrator, curing,
testing M25 design mix concrete as per IS 456:2000 (latest
revision) and as per tender specification in all items including cost
of form work and rendering but excluding cost of reinforcement.-
(A) foundation, footing, base of columns and mass concrete
SMC SOR-PAGE NO 14 MIX DESIGN
Providing, mixing, placing, compacting by machine vibrator, curing,
testing M25 design mix concrete as per IS 456:2000 (latest
4 revision) and as per tender specification in all items including cost
of form work and rendering but excluding cost of reinforcement.
work in : Upto G.L./P.L.
(2) Having cross sectional area more than 0.085 sq. mt.up to
(1) Having cross sectional area upto 0.08 sq.mt. 0.00 C.M. 8994.86
(2) Having cros sectional area more than 0.08 sq. mt and upto
SMC SOR-PAGE NO 14 MIX DESIGN
Providing & laying cement concrete 1:2:4 (1 cement : 2 sand :
graded stone agg. 20 mm nominal size) & curing comp. Includ. cost
5 of form work but exclu. Cost of reinforcement for reinforced
concrete work in : (A) Foundation, footing, Base of columns and
(C) Grade slab 84.00 C.M. 3637.34
(SOR SMC Pg No. 9 It No. 95)
Providing & fixing IS Mark TMT Bar FE 500D reinforcement for
6 R.C.C. work incl. bending, binding & placing in position etc. comp. 12990.00 Kg
SMC SOR, ITEM NO.-
Providing & construction brick work using Fly Ash bricks having
crushing strength not less than 35 Kg./sq.cm. in foundation &
plinth in C.M. 1:6 (1 cement:6 sand ) etc. comp. - Ground Floor
(SOR SMC Pg No. 1 It No. 9) 4.00 C.M. 4237.00
Filling available excavated earth (excluding rock) in trenches.
plinth, sides of foundations etc. in layers not exceeding 20 cm. in
depth consolidating each
disposited layer by ramming and watering.
(SOR SMC Pg No. 1 It No. 10) 551.00 C.M. 130.39
Providing & Applying 20mm. Th. Heavy Roller plaster on walls or
similar surfaces at all floor levels consisting of 12 mm av. Th.
Backing coat of C.M. 1:3 (1 cement:3 sand) & 8 mm. th. Finishing
9 coat of C.M. 1:1 (1cement: 1 sand) apply thick cement slurry and
apply roller horizontal as well as vertical ( two times ) up to good
quality and size of grain in elevation as per directed by engineer
(SOR SMC Pg No. 3 It No. 28) MR 49.00 S.M 324.00
DESCRIPTION Qty. UNIT AMOUNT
Providing & applying two coats of weather shield max paint (3
coats may be required in case of darker colours.)of ICI Dulux or
Apex Ultima of Asian Paint including applying exterior acrylic
primer coat as per manufacturers specification and directions in
shade and colour approved by architects, on exterior surfaces of
the building including scaffolding, preparing the surface, watering,
curing etc. complete and as directed by the architects and
Surface Preparation : surface is thoroughly clean, dry and free
from all loose dirt, chalk, grease, fungi,algae and flaking paint. This
10 can be achieved by brushing with a wire/ stiff coir brush, followed 49.00 S.M
by water jetting if required. Fill up all minor cracks and defects
with white cement and sand mixture in the ratio 1:3. For
application on previously painted wall, previous coatings of paint
must be thoroughly scraped off and Clean the surface thoroughly
using wire brushes.
Priming: Apply a liberal coat of exterior acrylic primer and allow it
to dry for 4-5 hours.Application of putty is not recommended.
Minimum 4-6 hours duration is required between each coat of
weather shield max paint
SMC SOR , COLOR WORK ITEM NO.- 17 Page No.
WORK ABOVE PLINTH LEVEL
Providing, mixing, placing, compacting by machine vibrator, curing,
11 testing M25 Design mix concrete as per IS 456:2000 (latest
revision) and as per tender specification in all items including cost
of form work and rendering but excluding cost of reinforcement
(2) Having cross sectional area more than 0.085 sq. mt .up to
Ground Floor 2.60 C.M. 11136.62
(SOR SMC - MIX DESIGN PG. NO-14)
(2) Having cros sectional area more than 0.08 sq. mt and upto
Ground Floor 2.00 C.M. 8075.85
(SOR SMC - MIX DESIGN PG. NO-14)
(3) Having more than 13 cm. Thickness
Ground Floor 3.00 C.M. 6727.93
(SOR SMC - MIX DESIGN PG. NO-14)
Ground Floor 0.50 C.M. 9419.25
(SOR SMC - MIX DESIGN PG. NO-14)
Ground Floor 1.10 C.M. 6913.25
(SOR SMC - MIX DESIGN PG. NO-14)
12 Providing & fixing IS Mark TMT Bar FE 500d reinforcement for
R.C.C. work incl. bending, binding & placing in position etc.comp.---
Ground Floor 1495.00 Kg 76.21
Brick work using common burnt clay building bricks having
13 crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:6
(1- Cement : 6 -fine sand)(C) Fly Ash Bricks
Ground Floor 17.00 C.M. 4511.97
First Floor 3.00 C.M. 4786.95
(SOR SMC Pg No. 2 It No. 16)
DESCRIPTION Qty. UNIT AMOUNT
Providing & Applying 15mm.th.cement plaster in single coat on
brick/ concrete walls similar surfaces for plastering & finished
14 even & smooth with a floating coat of cement slurry mixed with
admixture of lime or neeru in required proportion etc. comp. in C.M
1:3 (1 cement : 3sand)
(A) for wall and similar surfaces
Ground Floor 72.00 S.M 237.51
(SOR SMC Pg No. 3 It No. 25)
Providing & Applying 10mm.th.cement plaster in single coat on
brick/ concrete walls similar surfaces for plastering & finished
15 even & smooth with a floating coat of cement slurry mixed with
admixture of lime or neeru in required proportion etc. comp. in
C.M 1:3 (1 cement : 3sand)
(B) for ceilings and soffits of stairs
Ground Floor 18.00 S.M 214.60
(SOR SMC Pg No. 3 It No. 24)
Providing and fixing 150 mm wide, approved quality chicken wire
mesh (FRP / PVC) at junction of brick work and RCC work or two
dissimilar surfaces, at all heights fixed by nails, rowal plugs or tag
by cement mortar 1:3 before applying the plaster, including curing,
scaffolding all complete as directed.
Ground floor 6.00 S.M. 102.00
(SOR SMC Pg No. 11 It No. 124)
Providing 20 mm thick double coat mala cement plaster on
brick / concrete work for plastering comprising of base coat 12 mm
thick cement plaster in cement mortar (1 Cement : 4 coarse sand)
in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1
Cement : 2 Coarse sand) finished with trovel including scaffolding
curing etc. complete.
Ground Floor 83.00 S.M 272.48
(SOR SMC Pg No. 3 It No. 27) MR
Providing throating or plaster drip and moulding it to R.C.C. chajja
etc.comp.. For all floor
Ground Floor 7.00 R.M 41.66
(SOR SMC Pg No. 3 It No. 29)
Providing 20 mm deep finished groove in plaster in line and
level etc. Comp. For all Floor (M.R.)
Ground Floor 7.00 R.M 50.00
(SOR SMC Pg No. 3 It No. 30) MR
Providing and laying polished Kota stone slab flooring over 20mm
(Average) thick base of cement mortar 1:6 (1-cement : 6-coarse
sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and
20 jointed with grey cement slurry mixed with pigment to match the
shade of slab including rubbing and polishing etc. complete. (A)
Ground Floor 9.00 S.M 989.45
(SOR SMC Pg No.4 It No. 32)
Providing and laying polished Kota stone slab 25mm thick in risers
of steps,skirting Dedo and pillars laid on 10mm thick cement
mortar 1:3 (1-cement : 3-coarse sand) and jointed with gray
21 cement slury mixed with pigment to match the shade of slab
including rubbing and polishing etc. complete.
Ground Floor 3.00 S.M 1076.94
(SOR SMC Pg No.4 It No. 33)
DESCRIPTION Qty. UNIT AMOUNT
Providing and constructing sandwitch type Granite stone platform
0.6 mt. wide & 0.75 mt. height, including one end side granite stone
(Double Polish) of 1.25 mt. height & front granite stone patti of
cm wide, vertical partitions of half B.M. wall in C.M. 1:4 and 10mm
22 th. plaster in 1:3 with finishing smooth with cement slurry as
required and Stainless Steel sink of 0.45 mt x 0.45 mt size of
approved quality and make with required all fitings & fixitures etc.
comp as per instruction given by site in charge at all floors.
Ground Floor 0.00 R.M. 3128.00
(SOR SMC,Pg No.11, It No. 123) MR
Apply two coats of putty and two coats of primer of approved
brand and manufacture on new wall surface to give an even shade
23 including thoroughly brushing the surface free from mortar
dropping and other matter and sand papered smooth.
(A) for wall and similar surfaces
For all Floors 90.00 S.M 40.59
(B) for ceilings and soffits
For all Floors 90.00 S.M 40.59
SMC SOR ,coiour works,Pg No.15,item no.-4
Wall painting (two coats) with plastic emulsion paint of approved
brand and manufacture on undecorated wall surface to give an
24 even shade including throughly brushing the surface free from
mortar droppings and other foreign matter and sand papered
(A) for wall and similar surfaces
For all Floors 83.00 S.M 79.39
(B) for ceilings and soffits
For all Floors 0.00 S.M 79.39
SMC SOR , coiour works,Pg No.15,item no.-5
Providing and applying textured plaster as per design of ICI Dulux
or of Asian paint as per manufacturers specification and directions
in shade and colour approved by architects, on exterior surfaces of
25 the building including scaffolding, preparing the surface, watering, 83.00 S.M
curing etc. complete and as directed by the architects and
Providing & fixing 35mm.th. Flush Door Solid Double Core type
Both Face water proof Ply Vennered & 1.5 mm th.laminate shall
be pasted on both side with adhesives as specified by the
manufacturers. The laminate shall be as per approved shade &
texture, of make incl. Sal wood frames of finished size 12cm x
7cm.incl. S.S. Hinges with nessary screws & Anodized aluminum
fixtures & fastenings For all Floor
(SOR SMC Pg No.5 It No. 51) MR
Same as Above But Without Frame
All Floor 3.00 S.M 2520.00
(SOR SMC Pg No.5 It No. 52) MR
DESCRIPTION Qty. UNIT AMOUNT
Providing and fixing window having extruded aluminium colour
anodized section frame main outer size 63.50 x 38.10 x1.95 mm (of
Jindal section no.4605, @ Wt. 1.094Kg/mt) horizontal Two track
member size 61.85 mm x 31.75 mm x 1.20 mm (of jindal section
no:8687, @ Wt. 0.695 Kg/mt.) vertical member of size 61.85 mm x
31.75 mm x 130 mm (of jindal section no:8758 @ wt. of
kg/mt) with sliding shutters of horizontal member size 40 mm x18
mm x 1.29 mm ( of jindal section no:8949, @ Wt. of .456 Kg/mt)
vertical member of size 40 mm x 18 mm x 1.29 mm (of jindal
section no:8947, @ Wt. of 0.456 Kg/mt/section 8948, @ Wt. of
0.457 Kg/mt) with 5 mm thick tranparent bronze colour tineted
float glass with powder coated aluminium fittings and fixtures and
transparent silicon sealant glass fixing to frame as per details etc.
complete for window.For all Floors.
(A) Same as above but colour anodized 5.00 S.M 1705.67
SMC SOR Alluminium Work ITEM NO.3(A),Pg No.17
Providing & laying granite slab 18 mm thick in Window-Door
seal,Frames Etc laid on 10 mm thick cement mortar 1:4 (1
Cement: 4 Coarse sand) with necessary adhesive material and
finished with flush pointing in white or colour cement, including
rubbing & polishing comp. (Basic Rate: Rs. 1000.00/S.M.).For all
For all Floors. 2.00 S.M 2026.00
SMC SOR , PAGE No.4 ITEM NO.41 MR
Labour Charges For Edge Finished For Granite for all floors
For all Floors. 34.00 R.M 43.43
SMC SOR, PAGE No.4 ITEM NO.42
Steel work welded in built up sections,frame work including
cutting, hoisting, fixing in position and applying apriming coat of
red lead paint :-
30 (A) In beams and joists channels angles, tees, flats with connection
plats or angle cleats as in main and cross beams, hip and trussed 246.32 Qtl
purlins connected to common raffers and the like.
SMC SOR-PAGE NO 9 IT NO
Providing & Fixing 80 mm dia M.S. pipe as vertical post are beded
in 1:1.5:3 concrete also horizontaly in line and connecting to
purline angle etc by welding rereting etc. (a) Medium duty "B"
SMC SOR-PAGE NO 10 IT NO
Painting two coat (excluding priming coat) on new steel and
other metal surface with synthetic enemal paint, burshing to give
an even shade including cleaning the surface of all dirt, dust and
other foreign matters.
SMC SOR-PAGE NO 15 IT NO
Providing & fixing colouron galvaniced steel, zinc / aluminium
allus coated sheet 0.5 mm. thick roofing fixed with gslvanised
grom J or L hook bolts and bolt 8mm dia with bituman and impet
washer filled with white lead etc. Excluding the cost of purlins
rafter and trusses. (Tata / Jindal or equivalent)
SMC SOR-PAGE NO 9 IT NO
Providing & fixing 150mm wide 450mm over all semicircular
plain G.I. sheet class-3 gutter with iron brackets 40mm x 3mm
size bolts, nuts, washers etc. including marking necessary
connection with rain water pipes. (i) 0.63mm thick
DESCRIPTION Qty. UNIT AMOUNT
SMC SOR-PAGE NO 9 IT NO 106 MR
LAWN : Area cleaning and side grading, removing unwanted
materials, plants, chrubs,wild grass, weeds,debris,rubbish,etc.
Excavating up to depth 30 C.M surface dressing leveling, making
slopes for drainage according to landscape, Disposal of unwanted
materials with all labour and tools. Development of lawn including
preparation of bed ground, spreading and mixing the good soil with
Farm Yard Manure, Gypsum, fertilizer soil with farm Yard Manure,
Gypsum, Fertilizer bas required hand specified. Planting of lawn
grass bits roots of approved quality, watering and specified.
Planting of lawn grass bits roots of approved quality, watering, and
specified. Planting of lawn grass watering mowing, weeding etc.
maintenance of developed lawn for a period of 6 months.
(As per Garden Dept.)
Supplying on site plants with following specifications . Plants
would be in good condition and of specified height. The rates
would be inclusive of all taxes, sales tax, Octroi,transportaion etc.
2 complete F.O.R. site. Conditions of plant would be verified at the
time of selction as well delivery. All complete and as per
instructions of the Engineer-in-charge.
Lagerstroemia thorell II - 3.66m ht 10.00 Nos. 270.00
Millingtonia hortensis - 3.66m ht 10.00 Nos. 270.00
Azadirachta Indica - 2.13m ht 20.00 Nos. 270.00
Gresses & Bamboos
Bambusa valgaris - 1.83m ht. 30.00 Nos. 75.00
Nephrolepis exalotta smithi - 0.45x0.30m 40.00 Nos. 20.00
Champa - 3.66m ht. 10.00 Nos. 270.00
(As per Garden Dept.)
ELECTRIFICATION WORK OF BUILDING
INTERNAL WIRING
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of
1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up to 10 mtr length , in below
type of pipe erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected on PVC
1 / Metallic/Wooden box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary Lamp holder/ceiling
rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete Cat. III
Point wiring for secondary light point with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper wires, in below type of
pipe to be erected complete with earth continuity and necessary
connection with primary light with accessories erected on Metal /
PVC / wooden box covered covered with appropriate front plate
2 modules erected on / in wall / ceiling for open / concealed wiring. 106 Pt. 151.50
with necessary Lamp holder / ceiling rose / H.D.Connector as
directed.as per pipe erected with following type of accessories.
Note:- Maximum up to 6 mtrs length, excess will be considered as
Mains for Secondary Point.
DESCRIPTION Qty. UNIT AMOUNT
(f) with medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of
pipe erected with 6A Modular type switch and hum free EME step
type electronic fan regulator mounted and accessories with earth
3 continuity of following type erected on PVC / Metallic/Wooden 150 Pt. 629.23
box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected. with necessary ceiling rose /
(f) with medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete, Cat. III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of
pipe erected complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with appropriate
4 front plate modules erected on / in wall / ceiling as per pipe 8 Pt. 473.69
erected with following type of accessories.
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from
nearby switchboard/mcb db board
(f) with medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete, Cat. III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of
pipe erected complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with appropriate
5 front plate modules erected on / in wall / ceiling as per pipe 42 Pt. 697.91
erected with following type of accessories.
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire
from mcb db board.
(f) with medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete, Cat. III
Point wiring for Individual Plug with & earth wire both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi strand copper wires
up to 10 mtr length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front plate
modules erected on / in wall / ceiling as per pipe erected with
following type of accessories.
[III] For 16A Plug and 16 amp switch with 2-4 sq.mm Cu. Wire
with 2.5 sq.mm ( green) earthing wire from mcb d b board.
(f) with medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete, Cat. III
Point wiring for on board Looped Plug with 6A Modular type
switch & 5 pin socket erected on PVC / Metallic/Wooden box,
7 single mounting base frame covered with textured / metallic/white 36 Pt. 241.39
front plate modules erected on / in wall / ceiling with following
type accessories, Cat. III
Point wiring for Two Way Controlled Light Point with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (green) both are of .ISI marked
1.1 KV grade FRLS PVC insulated multi strand copper wires erected
in below type of pipe with 6A Modular type switches and following
type of accessories erected on PVC / Metallic/Wooden box, single
mounting base frame covered with textured / metallic/white front
plate modules erected on / in wall / ceiling as per pipe erected.
with necessary batten/angle holder or ceiling rose or
(f) with medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete, Cat. III
DESCRIPTION Qty. UNIT AMOUNT
Providing and erecting ISI mark Medium class RIGID PVC PIPES of
following size complete to be erected on/in wall or ceiling erected
with necessary PVC fittings & Junction boxes fixed with adhesive
9 solution & Clamps with following dia of pipes, in approved manner
Providing & erecting PVC Corrugated Flexible Conduit with
required nos. of coupling, PVC bushes, Check-nuts etc. complete of
10 following sizes.
Providing following type of Modular Type Accessories mounted
with PVC / metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed
by Engineer In charge.
(3) Two Pin/RJ-11 Telephone Socket
[A] For One Gang, Cat. III 0 Ea. 153.52 -
11 [B] For Two Gang, Cat. III 0 Ea. 200.99 -
(4) TV Co-axial Socket outlet, Cat. III 0 Ea. 153.52 -
(7) Blank Plate Single, Cat. III 30 Ea. 24.24
(8) Computer RJ-45 socket, Cat. III 0 Ea. 153.52 -
(22) 16/20/25 Amp. Modular Starter for Motor / A.C. Unit
Complete, Cat. III
(19) Modular Indicating Call Bell, Cat.III 0 Ea. 314.11 -
(20) Modular Buzzer, Cat.III 0 Ea. 143.42 -
Supplying & erecting UPVC Mini trunking (PVC Casing-n-
Capping) having double-locking arrangement with grooves,
trunking of size not below 12.5 mm in height as per IS with
12 accessories of PVC/Resin polypropylene not below 1.8 mm thick
duly sealed in joint & erected on wall / ceiling of following size .
Providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in following
type of pipe to be erected concealed in /flushed on wall/ceiling,
with 1.5 sq. mm copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of following size
(A) With medium class Rigid PVC pipe and accessories
(a) 2 wire 1.5 sq. mm 550 Mtr. 59.59
(b) 2 wire 2.5 sq. mm 1700 Mtr. 78.78
providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in following
type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm
copper conductor FRLS PVC insulated stranded wire of green
14 colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories
(a) 2 wire 4 sq. mm 0 Mtr. 107.06 -
(d) 3 wire 4 sq. mm 0 Mtr. 159.58 -
(g) 4 wire 4 sq. mm 160 Mtr. 172.71
Providing & Erecting approved make following size of TV Co-axial
flexible cable comprising inner conductor of solid bare copper
insulated with Foam PE & Secondary conductor made of poly -
Aluminium film bonded Al. Braids @ suitable coverage overall
sheathed with black PVC insulation.
Supplying & erecting approved make Telephone Cable
electrolytic copper conductor PE insulation twisted in two pairs,
& wrapped with FRLS PVC tape & sheathed with FRLS PVC or
HFFR outer Jacket suitable for telephone wiring & confirming to C-
DOT erected in existing pipe. of following size of conductors &
nos.of pairs. With necessary connections.
16 [A] Conductor Size 0.5 mm
DESCRIPTION Qty. UNIT AMOUNT
(2) Two Pairs 0 Mtr. 19.19 -
(b) Armoured [Jelly Filled] 0 Mtr. -
(1) Ten Pairs 0 Mtr. 120.19 -
(2) Twenty Pairs 0 Mtr. 190.89 -
(3) Fifty Pairs 0 Mtr. 446.42 -
Providing & erecting main Distribution (MDF) indoor type, back
mounted frame as per DoT standard approved with krone strips
(a) Suitable for 10 pair 0 Ea. 949.40 -
(b) Suitable for 20 pair 0 Ea. 1311.99 -
(c) Suitable for 50 pair 0 Ea. 1678.62 -
Supplying & erecting M.S. Box having 16 Gauge painted with red
oxide or Heavy duty PVC box erected flushed on wall or concealed
18 in wall with necessary plastering & finishing as directed of
following size.
Providing & erecting Switch board for Computer or electric
apparatus consisting of following items in single board erected
on PVC / Metal/Wooden board concealed/open with 3 mm thick
19 PC (Polycarbonate) / Acrylic sheet erected as directed
1 no. 6A/16A universal plug-switch combined., 3 nos. 6A Switch,3
nos. 6A 5 pin Plug
For Modular Type Accessories, Cat. III 44 Ea. 1081.71
Decorative call bell Ting-tong box type 250 volts complete
L.T. SWITCHGEAR AND DIST. BOARD & L.T. PANEL
MCCB 125 Amp , MICRO. BASED LSGD RELEASE MCB , 4 POLE,
MFM METER , R Y B INDICATOR, ON OFF INDICATIOR
40 AMP., FP MCB-B CURVE, 10 KA, WITH ON OFF INDICATOR :
40 AMP., FP MCCB, 25 KA, FOR FIRE PUMP - WITH ON OFF
21 INDICATOR : 1 No. 0 Ea. 152762.50 -
32 AMP., FP MCB-C CURVE, 10 KA, FOR DRINKING WATER PUMP
WITH ON OFF INDICATOR : 1 No.
32 AMP., FP MCB-CURVE, 10 KA,WITH ON OFF INDICATOR
(SPARE) : 1 No.
63 AMP., FP MCB-B CURVE, 10 KA (SPARE) WITH ON OFF
INDICATOR : 1 No.
40 AMP., FP MCB-B CURVE, 10 KA, (SPARE) WITH ON OFF
INDICATOR : 1 No.
16 AMP. FP MCB-B CURVE, 10 KA, (SPARE) WITH ON OFF
Providing and erecting Sheet Steel powder coated MCB
distribution board - flush / surface mounted fitted with busbar,
neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC
61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The
DBs should be used of same company of MCB to be used) suitable
(A) single phase incoming and horizontal single phase outgoing
(b) sheet steel double door (IP-43)
(B) three phase incoming and single phase horizontal type
outgoing Per phase isolation type (PPI)
(b) sheet steel double door
(iii)8 way (As Main GFLDB, FFLDB, SFLDB, TFLDB) 1 Ea. 3412.79
(iii) 8 way (As Raw Power DB {RPDB} GF + FF + SF) 0 Ea. 4025.86 -
(ii) 6 way (As A.C. DB {ACDB} GF + FF + SF) 0 Ea. 3437.03 -
23 RCCBs, 30 mA, 10 KA, 40 Amp., FP, Cat. III (INCOMER) 3 Ea. 2637.11
DESCRIPTION Qty. UNIT AMOUNT
24 RCCBs, 30 mA, 10 KA, 40 Amp.,DP, Cat. III 3 Ea. 2235.13
Providing and erecting Approved make RCCBs conforming to IS:
12640 and having sensitivity of 30 mA and Short Circuit withstand
capacity of 10 KA and suitable for operation on 3 phase and neutral
415V,50Hz. having characteristic of quick action & tripping with all
advance feature & do not incorporate any electronic component for
following Max. rating erected as directed.(iii) 63 Amps. FP Cat. III
26 MCB, 10 KA, 40 Amp., FP, Cat. III (INCOMER) 3 Ea. 638.32
27 MCB single pole 6A to 25A, 10 KA Cat. III (20 Amp) 57 Ea. 112.11
Providing & erecting 240 V MCB double pole switch for motor &
inductive load (C Curve) having 10 KA breaking capacity &
confirms to IS : 8828 in existing box having following capacity, Cat
III, (A) 6 to 32 Amp.
Providing & erecting 240 V MCB double pole switch for lighting
Load (B Curve) having 10 KA breaking capacity & confirms to IS :
8828 in existing box having following capacity, Cat (III), 6 to
Providing & erecting 415 V MCB Four Pole for Motor &
Inductive Load (C Curve) having 10KA breaking capacity &
30 confirms to IS :8828 in existing box having following capacity, Cat
(a) 6 to 32 Amp. Cat III, 4 Ea. 595.90
(c) 63 Amp. Cat III, 1 Ea. 737.30
Providing and erecting Approved make Four pole moulded case
circuit breaker having breaking capacity ICU of 35 KA. at 415 V.
having normal current rating 125A. with Fixed thermal & magnetic
release suitable to work on A.C.supply 50 c/s. with all internal
connections, spreader tinned copper & complete erected in existing
16 G.M.S. housing. ICS=100% of ICU only Cat III
Providing and erecting busbar chamber confirming to IS-375
fabricated from 16 G.M.S. sheet, dust & vermin proof having hinged
door with rubber gasket and necessary busbar supports with
COPPER busbar having current density not more than 1.6 Amp. /
32 sq.mm (Rated current / cross section area) duly wrapped with 1 Rn.Mtr 5731.75
colour insulation tape for phase sequence, three phase & neutral
each suitable for following current capacity with necessary
painting mounted on wall or pedestal frame of required size with
necessary connections. (B) Suitable for 200 Amp. capacity
Supplying & erecting approved make Electronics Starter and
relay for air conditioners in ABS plastic moulded housing.
Company fabricated with bakelite terminal for connection with
silver coating bimetallic contact in switching device for o/p with
following features.
33 (1) Low Voltage Protection below 130 V 0 Ea. 886.78 -
(2) High Voltage protection above 270 V
(3) Overload protection for 2-5, 4-10, 8-14, 10-16, 14-22 Amp.
(inverse time chara-)
(4) Indicating LEDs for AC on LV, HV, O/L, T/D
(5) With unique feature of 3 minute of time delay
Plastic enclosure fitted with DIN rail suitable for incorporating
One / Two nos. MCB
Plastic enclosure fitted with DIN rail suitable for incorporating
Three /Four nos. MCB
Sheets steel powder coated enclosure suitable for incorporating
One/Two nos. MCB.
Supplying & fixing box for housing RCCB + MCB combination made
of 18 SWG sheet steel duly powder coated with gasket, dust &
vermin proof bakelite shield two earthing terminals for following
type of RCCB, RCCB + MCB [b] For 4 Pole
DESCRIPTION Qty. UNIT AMOUNT
Providing and erecting metallic vitrified danger notice board as
38 per language suggested by engineer incharge for MEDIUM 1 Ea. 69.69
VOLTAGE installation to be erected as per IS-2551.
Providing & erecting Medium Voltage Danger Notice Board
39 sticker as per language suggested by engineer incharge of 1 Ea. 26.26
standard size as per IS-2551
providng and erecting Approved make single phase electronic
energy meter rating 5A/20A/40A based on ASIC (Application
Specific integral circuit) digital technology with accuracy Class-I,
temper proof, free from effect of external magnetic field with
phase, earth, reverse and impulse indications, 6 digit electro-
mechanical counter suitable to work on 120 V to 300V, 45 - 55 Hz.,
housed in robust enclosure complete to be erected as directed with
3 year replacement guarantee. Cat. III
providng and erecting Approved make energy meter 3 phase
wire unbalanced load rating, 10A to 60 Amp. based on
ASIC(Application specific Integral Circuits) digital technology with
accuracy Class - 1 , temper proof, free from effect of external
magnetic field with 3 phase indication, earth & impulse indication,
6 digit electro mechanical impulse counter, suitable work on 120 V
to 300V per phase 45-55 HZ, housed in robust enclosure with
erection as directed. Cat. III
INDOOR LIGHTING ITEM
Supplying and erecting LED indoor fittings with LEDs of wattage
0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet Steel conforming to
IS: 513/CRCA/ aluminium die cast powder coated and high U.V. &
corrosion resistance with diffuser with company mark/name
160V to 270V, Power Factor more than 0.9, THD < 15%,CCT
K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 % ( fitting required LM-79 & LM-80
42 Certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may select
any wattage capacity between the ranges shown.)
(A) Tube Light with integral driver
(i) 5-10 Watts, Surge-2 KV, IP-20, conventional 1 to 2 feet, Cat. III 0 Ea. 165.64 -
(iii) 18-20 Watts, Surge - 2KV,IP-20, conventional 4 feet 0 Ea. 295.93 -
(iv) 22-24 Watts, Surge - 2KV,IP-20, conventional 4 feet 269 Ea. 373.70
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet,Cat. III 0 Ea. 535.30 -
Supplying and erecting LED lamps with following wattage capacity
of 220 to 240 voltage, minimum 15000 burning hours life, 500 V in
built-surge protection,Polycarbonate diffuser, mounting suitable
for E14 / E27 / B22 lamp holders, pf >=
(A) LED Lamps integral type, with PC diffuser suitable LAMP
holder, Cat. III
(i) 2 to 3 watts 0 Ea. 69.69 -
(ii) 5 to 8 watts 18 Ea. 112.11
Supplying and erecting LED indoor fittings with LEDs of wattage
0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet Steel conforming to
IS: 513/CRCA/aluminium pressure die cast powder coated and
high U.V. & corrosion resistance with diffuser housed in
aluminium casted body with company mark/name 160V to 270V,
Power Factor more than 0.9, THD < 15 %,CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
44 fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
DESCRIPTION Qty. UNIT AMOUNT
(A) Square/ Circular shaped Surface/Recessed Mount
Downlight with provision for spring loaded mounting clips
(ii) 11-15 watts, Surge-2 KV, Cat. III 0 Ea. 427.23 -
(iii) 16-20 watts, Surge-2 KV, Cat. III 0 Ea. 589.84 -
(iv) 22-24 watts, Surge-2 KV, Cat. III 0 Ea. 758.51 -
(B) LED Panel Light with provision for Plane front frame with
translucent cover fixed to housing complete.IP20
(vi) 36 watts, 24" x 24", Surge- 2KV, Ct. III 0 Ea. 1794.77 -
OUTDOOR LIGHTING ITEM
Supplying and erecting LED street light / Flood light fittings with
High power White LEDs wattage of 3 Watt and above assembled on
single MCPCB, efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V,Power Factor
more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity
ratio >0.45, Luminaire efficacy> 100 lumens/watt. LED driver
efficiency > 85 %. ( fittings required LM-79 & LM-80 certificates)
(NOTE: Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any wattage
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light
must have 440VAC line supply with over-voltage protection.
(i) above 36 to 48 watts, Cat. III 11 Ea. 3345.12
(B) Flood Light (IP-65), Surge protection -4KV integral and ,Light
must have 440VAC line supply with over-voltage protection.
(vii) above 200 to 250 watts, Cat. III 3 Ea. 10818.11
FAN AND RELEATED ITEM
Supply, Installation, Testing and Commissioning of suitable sweep,
BEE 5 Star rated, Ceiling fan with Brush Less Direct Current
(BLDC) permanent ferrite magnet Motor, class of insulation: B,
Rust free 3 nos.Aluminium blades, 2 nos. canopies, shackle kit with
earthing provision, copper winding, Power factor not < 0.9, Service
Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM,
46 350 RPM,230v (tolerance as per IS : 374-2019), THD < 10%, 0 Ea. 2629.03 -
compitible with electronic regulator unit for Speed Control and all
remaining accessories including safety pin, nut bolts, washers,
temperature rise = 75 degree C (Max.), suitable for 140 to
Voltage and rectifier circuit with surge, over current and overload
protection , 50 Hz, Single phase AC Supply, earthing etc. Complete
as required.[ Make shall be approved by Engineer in Charge] (A)
Providing & erecting Approved make Power Saving 50 Watt
Ceiling Fan with double ball bearing ISI mark with Condenser
47 volt A.C. 50 Hz 1200 mm sweep complete having 3blades with 150 Ea. 1948.29
aluminium blades with , canopy & 30 cm. down rod erected with
earthing.(Make shall be approved by Engineer in charge))
Supplying and erecting 19 / 20 mm. nominal bore Medium Class
48 M.S. Pipe down rod erected duly painted for fan complete with 150 Mtr. 108.07
proper insulation without leakage and earthing.
Supplying & erecting fan hook box of 10 mm M.S. round bar
bounded to the RCC bars up to 50mm length each side and pierced
through a 16 Gauge M.S. box / Heavy Duty PVC box complete
erected concealed in Ceiling with necessary finishing.
Providing 2.5mm.thick laminated acrylic sheet to cover the fan
hook or Fan box.
DESCRIPTION Qty. UNIT AMOUNT
Supplying & erecting single phase approved make industrial
exhaust fan suitable for medium duty ring mounted low noise
51 operation suitable for medium duty having following dia size and 24 Ea 2054.34
maximum speed in RPM
[A] 305 mm dia 900 RPM, Cat. III
52 Providing suitable M.S. louver shutter of the Exhaust fan. 0 Ea. 368.65 -
Supplying & erecting electro galvanised G.I. wire micro mesh jali
53 cover of grade 304 required size with suitable wooden frame duly 0 Sq. Mtr 634.28 -
fitted in wall outside of exhaust fan for insect protection.
Providing & erecting fresh air fan 250 mm dia with square frame
make of ABS body with louvers, Cat. III
Supplying and erecting approved make oscillating type medium
duty bracket fan with Aluminium Blades A.C. 23OV. 50cy/s, with
thermal overload protection wall mounted with height adjustment
55 and rotary tilting device complete with guard, pull cord for speed 0 Ea. 3518.44 -
and oscillation flexible Core plug top complete erected with lead
wires as directed.
EARTHING SYSTEM
Providing and erecting required size HOT deep Galvanised iron
56 strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, 10 Kg. 77.77
Motors etc. using proper clamp.
57 Providing and erecting Annealed bare Copper wire 8 to 16 SWG. 2 Kg. 794.87
Providing and erecting HOT deep Galvanised iron strip wire 8 to
Providing and erecting Pipe type earthing having 150 cms. long
and 2.5 cms. dia. galvanised iron pipe with coupling and buch
buried in specially prepared earth pit complete with necessary
SWG earth wire.
Providing and erecting Pipe type earthing with 40 mm dia
mtr long 'B' grade G.I. pipe with necessary coupling buch buried in
specially prepared earth pit & G.I. earth wire of 8 SWG erected &
connected as directed
For using salt and charcoal / coke as required for pipe type
Supplying & erecting in earthpit of minimum bore dia. 225mm size
approved make Safe Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200
Micron galvanising, Inner pipe dia of 40 mm having 200-250
Micron galvanising, connection terminal dia of 14 mm with
constant ohmic value surrounded by highly conductive compound
with high charge dissipation suitable for following type of
applications with chamber and heavy duty cover.(approved make
OEM has to submit test certificate including value of earth
resistane of installation.
62 [B] For Electrical installation up to 11 KV located in other than
normal soil i.e. Soft Rock, Marshy Soil etc.
-Length of Pipe : 2 mtr 1 Ea. 7095.25
-Back filling Compound :1 no. Bag of 25 Kg. two for body earth and
one for neutral earth
[C] For Electrical Installation covering Transformer Neutrals,
Lightning arrester Earthing, A.C.Plant & Sensitive Computer
System(like Automation, SCADA)i.e. independent Earthing
located in other than normal soil i.e. Soft Rock, Marshy Soil etc..
-Length of Pipe : 3 Mtrs.
-Back filling Compound :2 nos Bags of 25 Kg.
CABLES, WIRE AND TERMINATIONS
DESCRIPTION Qty. UNIT AMOUNT
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable
multistrand Aluminium conductor for 1.1 KV. to be laid on wall
63 with necessary clamps or in existing trench / pipe of following size
of cables (From DISCOM energy meter to Main L.T. panel)
(G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core) 0 Mtr. 855.47 -
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable
multistrand Copper conductor for 1.1 KV. to be laid on wall
64 with necessary clamps or in existing trench / pipe at road crossing
or floor of following size of cables.
(A) 3 1/2 core 25 Sq. mm ( 10 Sq. mm 1/2 core) 0 Mtr. 1586.71 -
Making trench in soft soil of suitable width of 90 cm deep for
65 laying cable or locating the fault all over the run and back filling 0 Mtr. 46.46 -
the same and making the surface as normal ground.
Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm.
below ground across the road crossing or on floor with necessary
material in an approved manner and making the ground as per
original. (F) 100 mm dia.
Providing & laying approved make Double walled corrugated
pipes (DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at required -
67 depth in existing trench for laying of cable. below ground / road
surface for enclosing cable,
(A)50 mm outer dia 130 Mtr. 62.62
(B)63mm outer dia 0 Mtr. 73.73 -
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable
multistrand Copper conductor for 1.1 KV. to be laid on wall
68 with necessary clamps or in existing trench / pipe at road crossing
or floor of following size of cables.
(A) 3 1/2 core 25 Sq. mm ( 10 Sq. mm 1/2 core) 0 Mtr. 1345.32 -
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable
multistrand / Solid Copper conductor for 1.1 KV. to be laid on
wall with necessary clamps or in existing trench / pipe at road
69 crossing or floor of following size of cables.
(A) 4 core 2.5 Sq. mm 0 Mtr. 269.67 -
(B) 4 core 4 Sq. mm 0 Mtr. 362.59 -
(C) 4 core 6 Sq. mm 0 Mtr. 508.03 -
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable
multistrand Copper conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe at road crossing
or floor of following size of cables.
(A) 4 core 10 Sq. mm 0 Mtr. 673.67 -
(B) 4 core 16 Sq. mm 0 Mtr. 984.75 -
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable
multistrand / Solid Aluminium conductor for 1.1 KV. to be laid on
wall with necessary clamps or in existing trench / pipe of
following size of cables (B) 4 core 6 Sq. mm
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable
multistrand Aluminium conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe of following size
(A) 4 core 16 Sq. mm 0 Mtr. 151.50 -
(B) 4 core 25 Sq. mm 100 Mtr. 188.87
(C) 4 core 35 Sq. mm 0 Mtr. 253.51 -
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable
multistrand Aluminium conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe of following size
73 (A) 3 1/2 core 25 Sq. mm ( 16 Sq. mm 1/2 core) 0 Mtr. 180.79 -
(B) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core) 0 Mtr. 217.15 -
(C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core) 0 Mtr. 281.79 -
(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) 0 Mtr. 372.69 -
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core) 0 Mtr. 484.80 -
DESCRIPTION Qty. UNIT AMOUNT
Providing and, fixing heavy duty flange type brass double
compression type cable gland with rubber ring for PVC
insulated armoured cable complete with out going tails, insulating
tape etc for following size of cables.
Providing and, fixing heavy duty flange type brass cable gland
with rubber ring for PVC insulated armoured cable complete with
out going tails, insulating tape etc for following size of cables.
(B) 2 to 4 core 6 Sq. mm 25 Ea. 38.38
(C) 2 to 4 core 10 Sq. mm 0 Ea. 38.38 -
(D) 2 to 4 core 16 Sq. mm 0 Ea. 47.47 -
(E) 2 to 4 core 25 Sq. mm 4 Ea. 51.51
Solder less crimping type Aluminium lugs conforming to IS
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner.
Solder less crimping type Copper lugs conforming to IS suitable
for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut
bolts in an approved manner.
Supplying & erecting approved make LAN cable of following size in
existing pipe as per direction [C] CAT -
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper
79 cable 1.1 KV grade to be erected as directed of following size.
(E) 12 core 2.5 sq.mm 0 Mtr 393.90 -
WATER COOLER AND PURIFIER
Providing and erecting water cooler having storage capacity
80Ltr. & cooling capacity 40 Ltr.per hour @ an ambient temp of 45˚
C. The outlet temp. of the water should drop by 15˚ C within a hour,
The water cooler should be comprising of hermetically sealed
compressor, fan motor, condensing unit, water tank surrounded by
evaporating coil, thermostats, relay etc. complete with necessary
inlet & outlet connection. The body of water cooler will be made
from Stainless Steel.
81 SITC of Water Purifire Eureka Forbs Make AG 200 or Equivalent 4 Ea. 11615.00
Supplying & erecting bank of all polypropylene condenser (APP
type) with standard capacity of 2,3,5,7, 10,12.5 & 15 KVAR units of
P.F. correction for operation on 3 phase 50 c/s, 400 /440V (+ / -
82 10%) with externally discharging resistance, earthing terminal & 0 Ea. 582.77 -
built on angle iron of channel iron frame work and provided with
terminal cover box. Complete erected on provided iron bracket or
on floor duly tested by license.
PUMP SETS AND STARTERS
DESCRIPTION Qty. UNIT AMOUNT
Providing & erecting open well type horizontal mono block
pump set with stainless steel body having following specification.
83 (D) 1 HP Three phase open well motor pump set suitable for 190 2 Ea 9266.75
LPM discharge @ 21 mtr. head, suitable for 32mm dia. delivery
Supplying submersible pump set suitable for bore of 100 mm.
dia. or more having three phase motor capacity not more than
84 H.P. of different range with following capacity 1 Ea. 20901.95
(A) (20 stage) 170 to 185 LPM discharge at 57 to 48 mtrs.
Respectively head suitable for 50 mm dia. delivery pipe, Cat. III
Supplying & erecting approved make self-priming domestic
monoblock water pump with 1 H.P motor, suitable for operation
on 230 volts, 50c/s. AC supply with metallic flange, and M.S.
impeller delivery and following discharge
(a) 40 LPM at 24 mtrs. head suitable for 25mm dia. Delivery. Cat.III
Supplying and erecting push button operated fully automatic Star-
Delta starter with 3 Nos. of 15A.rating contactors and directly
operated thermal overload relay having 10-21A range and
86 erected in sheet steel enclosure for 3 phase 415V. 50 c/s. A.C.
motors from 7.5 to 15H.P. complete erected on
(A) P.W. Block with necessary connection, Cat.III 0 Ea. 10483.80 -
(B) Angle iron frame add to the above 0 Ea. 204.02 -
Supplying and erecting Direct On-line Electronics Starter with 2-
5/4-10/8-14/10-16 Amp. Rating relay (variable current setting)
directly operated in totally insulated elegant enclosure and
Amp. Rating power relay with start - stop button for single phase
operation up to 3 HP as per complete erected on P.W. Block with
following features.
Low voltage cut off below 140 V
High voltage cut off above 280 V
Overload protection
Indicating LEDs for motor on lv, hv & overload tripping. [Cat.II]
Supplying and erecting Direct-on-line, Starter with 15A.rating
contractor and with 4-14A. range, directly operated thermal
88 overload relay in sheet steel enclosure for 3phase 415V.50 c/s. A.C. 3 Ea. 2046.26
motor up to 7.5 H.P.complete erected on P.W. Block with necessary
connection. Cat.III
Supplying & erecting approved make Automatic liquid level
controller 6A. with sensor testing as per instruction of Engineer in
charge on site complete with wiring connection with existing wires
, with copper conductor from pump to upper and lower tank.
Providing and erecting ISI marked PVC insulated PVC Sheathed
Flat flexible Submersible copper cable approved make of following
(B) 3 Core x 2.5 Sq. mm. 300 Mtr. 104.03
Supplying & erecting 20 Amp 10 KA ‘C Curve’ single pole MCB
with 20 Amp. Plug socket, company fabricated powder coated
91 sheet steel enclosure erected as directed with connection.
[A] Metal Clad Socket with metal clad top. Cat.III 0 Ea. 527.22 -
[B] 15 Amp. / 5 Amp. Five pin Universal Socket Cat.III 0 Ea. 660.54 -
INVERTOR STABILIZER
92 Supplying and erecting of 1850VA Sine wave Digital Inverter 0 Ea. 13763.08 -
93 Supplying and erecting of 12V/150AH Tubular battery for 1 hrs 0 Ea. 17747.75 -
battery backup.
94 Supplying and erecting of 1KVA Stabilizer. 0 Ea. 10225.64 -
DESCRIPTION Qty. UNIT AMOUNT
Supplying and erecting approved make online Un-
interruptible Power Supply system comprising flat cum-boost
charger, static Inverter & sealed maintenance free SMF batteries.
The charger having operating capacity for input 160-270V AC &
inverter having output 230V,50 Hz Ac with 0.8 load power factor Ea. 24822.77 -
with battery, over/under voltage output with over load & short
95 circuit protection equipment. The system housed in CRC sheet duly
powder coated paint with following power backup.with MS painted
batteries stand, 10% Overload capacity for momentary load. (FOR
class room) (A) 1 KVA with 1Hr Backup 40058.62 -
(B) 2KVA with 1Hr Backup 0 Ea.
(C) 3 KVA with 1Hr Backup 1 Ea. 69331.05
(D) 5 KVA with 1Hr Backup 0 Ea. 128270.00 -
OUTDOOR & CAMPUS LIGHTING ITEM
96 SETC of GI Pipe Pole | 6 m Long 3 Nos. 5470.00
97 SETC of Bracket | single arm 0.5 m 14 Nos. 973.00
98 SETC of Bracket | Double arm 0.5 m 0 Nos. 1364.00 -
99 SETC of Bracket | Triple arm 0.5 m 0 Nos. 2441.00 -
100 SETC of Bracket | single arm 1.0 m 0 Nos. 1586.00 -
101 SETC of Bracket | Double arm 1.0 m 0 Nos. 2513.00 -
102 SETC of Bracket | Triple arm 1.0 m 0 Nos. 3308.00 -
103 Providing & Constructing 1:2:4 CC foundation of 6 m long GI Pipe 3 Nos. 1440.00
Supply and laying of GI "B" grade pipe for cable guard/ road
crossing with making of Zari for 40 mm Ø
Supply and laying of GI "B" grade pipe for cable guard/ road
crossing with making of Zari for 50 mm Ø
106 Cable end termination for 4 x 6 sq mm (Single Cable) 30 Nos. 130.00
107 Cable end termination for 4 x 10 sq mm (Single Cable) 0 Nos. 150.00 -
108 SETC of 1.1 kV grade XLPE insulated Al conductor armoured cable | 450 m 120.00
109 SETC of 1.1 kV grade XLPE insulated Al conductor armoured cable | 0 m 131.00 -
Laying of cable with excavation of trench having depth of 75 cms
110 and refilling with clay and covering with 38 mm Ø ID DWC pipe to 200 m 150.00
be laid in | Soft soil/ Kachcha Road
Laying of cable with excavation of trench having depth of 75 cms
111 and refilling with clay and covering with 38 mm Ø ID DWC pipe to 0 m 180.00 -
be laid in | Hard Murrum/ Asphalt Road
Laying of cable with excavation of trench having depth of 75 cms
112 and refilling with clay and covering with 50 mm Ø ID DWC pipe to 0 m 160.00 -
be laid in | Soft soil/ Kachcha Road
Laying of cable with excavation of trench having depth of 75 cms
113 and refilling with clay and covering with 50 mm Ø ID DWC pipe to 0 m 190.00 -
be laid in | Hard Murrum/ Asphalt Road
Supply & erecting PVC/ XLPE insulated ISI marked unarmoured
copper cable 1.1 kV grade | 3 x 1.5 sq mm
Supply & erecting PVC/ XLPE insulated ISI marked unarmoured
copper cable 1.1 kV grade | 3 x 2.5 sq mm
SETC of SMC press moulded composite FRP (Plastic) loop- in, loop-
116 out, dust & water proof, junction box, 2 mm thickness as per 14 Nos. 1050.00
detailed specifications, terms & conditions of the tender: -
S.E.T.C. of LED Streetlight Luminaires complete with all accessories
for Road having width of 12 m (Side Arrangement) ≈ 40 W
S.E.T.C. of LED Streetlight Luminaires complete with all accessories
for Road having width of 18 m (Side Arrangement) ≈ 120 W
DESCRIPTION Qty. UNIT AMOUNT
120 SETC of CCMS with GI Box {Capacity 6 kW, 1 Ø} & foundation 0 Nos. 51300.00 -
121 SETC of CCMS with GI Box {Capacity 9 kW, 3 Ø} & foundation 0 Nos. 62900.00 -
Painting the number and words for (streetlight pole numbering
and back ground of colour as per Zone Code) inventory
Identification with good quality of enamelled paint up to
characters + 50 mm Height
Pipe type Earthing having 150 cms long and 2.5 cms. Ø GI pipe with
coupling and buch buried in specially prepared earth pit complete
with necessary 25 x 3 mm size GI earthing strip using salt and
charcoal/ coke as required for pipe type earthing
CCTV WORK ABSTRACT
Supply, Installation, Testing & Commissioning of outdoor 2 MP IP
Dome Camera of 1/2.8" Progressive CMOS Sensor with resolution
30 fps @ 2048x1536 & Manual Vari Focal f = 3- 9 mm Field of View
40° ~ 80° (H), 30° ~ 60° (V) IR range upto 30 Mtr Smart IR Min.
Illumination 0.1 Lux @ F1.4 (Color), 0.01 Lux @ F1.4 (B/W) Noise
Reduction ; Compression Technology H.265, H.264, MJPEG with
simultaneous streams ; S/N Ratio 51.5 dB Dynamic Range 110 dB
WDR; two way Audio ; on board SD/SDHC/SDXC card slot ; P-iris
Lens & Digital Image Stabilization ; ONVIF IP43, CE, FCC Class A,
UL listed with all required accessories.
Supply, Installation, Testing & Commissioning of outdoor 2 MP IP
Bullet Camera of 1/2.8" Progressive CMOS Sensor with resolution
30 fps @ 2048x1536 & Manual Vari Focal f = 3- 9 mm Field of View
40° ~ 80° (H), 30° ~ 60° (V) IR range upto 30 Mtr Smart IR Min.
Illumination 0.1 Lux @ F1.4 (Color), 0.01 Lux @ F1.4 (B/W) Noise
Reduction ; Compression Technology H.265, H.264, MJPEG with
simultaneous streams ; S/N Ratio 51.5 dB Dynamic Range 110 dB
WDR; two way Audio ; on board SD/SDHC/SDXC card slot ; P-iris
Lens & Digital Image Stabilization ; ONVIF IP43, CE, FCC Class A,
UL listed with all required accessories.
Supply, Installation, Testing and Commissioning of Network Video
Recorder with maximum 64 IP Cameras, up-to 4 HDD slots,
simultaneous 64 channels playback and H.265+ / H.265 / H.264
recording supported.
Supply, Installation, Testing and Commissioning of 6TB
Surveillance HDD for 30-days motion based recording storage
SITC of 24 x 10/100/1000BASE-T ports
4 x Gigabit RJ45/SFP Combo ports
Advanced L2 switching and security features
L2+ Static Routing
Supplying & erecting approved make LAN cable of following size in
existing pipe as per direction [E] CAT - 6 shielded
Providing & erecting PVC Corrugated Flexible Conduit with
7 required nos. of coupling, PVC bushes, Check-nuts etc. complete of 1300 Mtr 20.00
following sizes. (2) 25 mm
55 Inch FHD android TV with HDMI ports: Typically 3 USB ports:
Typically 2 Ethernet port, Bluetooth
9 SITC of 10m HDMI Cable 1 Nos. 8,000.00
10 SITC of 20m HDMI Cable 2 Nos. 9,000.00
11 SITC of 20m VGA Cable 0 Nos. 4,700.00
12 SITC of 10m VGA Cable 0 Nos. 4,000.00
DESCRIPTION Qty. UNIT AMOUNT
Keyboard : Standard Full Size 104 key USB Keyboard (should be
regular in size and not be slim type)
Mouse(Wired) : Two button scroll USB optical mouse with pad
Mouse(Wireless) : Wireless Optical Mouse (2-Button + Scroll
Wheel), Connects via USB receiver for cable-free conveniencewith
FIRE FIGHTING SYSTEM WORKS
A PUMPS & CONTROL PANELS
A1 MAIN PUMP :-
HORIZONTAL CENTRIFUGAL MONOBLOCK PUMP SET, CAPACITY 1 NOS 1,07,829.75
@ 1250LPM AT @ 70METER HEAD, @30HP,
C.I. IMPELLER, @2900 RPM.
(MAKE:- KIRLOSHKAR / LUBI)
A2 JOCKEY PUMP :-
VERTICLE INLINE TYPE JOCKEY PUMP SET, CAPACITY @ 180LPM
AT @ 70 METER HEAD, @5.5HP, @2900 RPM. 1 NOS
(MAKE:- KIRLOSHKAR / LUBI)
A3 DIESEL PUMP :-
MECHANICAL SEAL, HORIZONTAL END SUCTION TYPE DIESEL 1 NOS 3,44,137.50
PUMP SET, CAPACITY @ 900LPM AT @ 60METER HEAD, @25HP,
C.I. IMPELLER, @2300 RPM.
(MAKE:- KIRLOSHKAR / LUBI)
A4 ELECTRICAL PANEL :-
COMBINED ELECTRICAL AUTO CONTROL PANEL FOR MAIN + 1 NOS 49,990.50
JOCKEY + DIESEL PUMPS WITH EARTHINGS AND SIREN.
(MAKE:- L&T / SCHINDLER)
A5 COPPER FLEXIBLE CABLE WITH CONDUITS & FITTINGS :-
(A) 4 CORE X 6 SQ.MM. (MAIN PUMP) 20 MTRS 152.54
(B) 4 CORE X 2.5 SQ.MM. (JOCKEY PUMP) 10 MTRS 235.46
(C) 6 CORE X 1.5 SQ.MM. (DIESEL PUMP) 10 MTRS 235.46
(D) 2 CORE X 1.5 SQ.MM. (PRESSURE SWITCH) 30 MTRS 108.68
(MAKE:- POLYCAB / RR)
(NOTE:- CABLE LENGTH MAY VARRY TENTATIVE)
A6 G.I. PERFORATED CABLE TRAY :-
(NOTE:- LENGTH MAY VARRY TENTATIVE)
B PUMP ROOM VALVES & PIPING
B1 C.I. "Y" TYPE STRAINER:-
PROVIDING AND FIXING OF C.I. "Y" TYPE STRAINER WITH MS
FLANGES, GI NUT, GI BOLT, GI WASER & RUBBER GASKET ETC.
COMPLETE AS REQUIRED.
(MAKE:- ZOLOTO / SANT)
(A) 150MM DIA 1 NOS 17,720.32
B2 BUTTERFLY VALVE :-
DESCRIPTION Qty. UNIT AMOUNT
PROVIDING AND FIXING OF BUTTERFLY VALVE WITH MS
FLANGES, GI NUT, GI BOLT, GI WASER & RUBBER GASKET ETC.
COMPLETE AS REQUIRED.
(MAKE:- ZOLOTO / SANT)
(A) 150MM DIA 4 NOS 5,790.32
(B) 100MM DIA 2 NOS 5,200.00
(C) 80MM DIA 1 NOS 2,843.36
(D) 65MM DIA 1 NOS 2,614.42
B3 C.I. DUAL PLATE NON-RETURN VALVE :-
PROVIDING AND FIXING OF C.I. DUAL PLATE NON-RETURN VALVE
WITH MS FLANGES, GI NUT, GI BOLT, GI WASER
& RUBBER GASKET ETC. COMPLETE AS REQUIRED.
(MAKE:- ZOLOTO / SANT)
(A) 100MM DIA 2 NOS 6,350.00
(B) 65MM DIA 1 NOS 4,640.66
B4 FORGED BRASS BALL VALVE :-
PROVIDING AND FIXING OF FORGED BRASS BALL VALVE
SCREWED END (SUITABLE FOR WORKING PRESSURE
(MAKE:- ZOLOTO / SANT)
(A) 25MM DIA (FOR PUMP HEADER DRAIN) 1 NOS 830.51
(B) 15MM DIA (FOR PRESSURE SWITCH) 3 NOS 728.81
B5 PRESSURE GAUGE :-
PROVIDING AND FIXING DIAL TYPE PRESSURE GAUGE WITH
ISOLATION BALL VALVE SUITABLE FOR WORKING PRESSURE
MENTIONED. COST SHALL BE INCLUSIVE OF PROVIDING ANY 4 NOS
SHORT PIECES, NIPPLES, ELBOWS WITH SYPHONE TUBE ETC
REQUIRED. (0-21 KG./CM2)
(MAKE:- BAUMER / H.GURU / EXCEL)
B6 PRESSURE SWITCH :-
PROVIDING, FIXING, TESTING AND COMMISSIONING OF PRESSURE 3 NOS 3,728.81
SWITCH SUITABLE FOR AUTOMATION OF PUMP ETC REQUIRED.
(MAKE:- DANFOSS / HONEYWELL)
SUPPLY, INSTALLATION, TESTING & COMMISISONING OF
G.I. "C" CLASS PIPE AS PER IS 1239 WITH PAINTING
(1 COAT OF ZINC OXIDE PRIMER AND 2 COATS OF PO RED PAINT),
SUITABLE TYPES OF SUPPORTS, HILTI FASTENERS, BOLTS, NUTS
(GALVANISED), CLAMPS, "U" BOLTS, FITTINGS SUCH AS
REDUCERS, TEES, ELBOWS, FLANGES. INCLUDING CUTTING,
WELDING, FIXING IN/ON WALLS, CEILING BY USING SUITABLE
(A) 150MM DIA 18 MTRS 2,445.74
(B) 100MM DIA 4 MTRS 1,800.00
(C) 80MM DIA 2 MTRS 1,700.00
(D) 65MM DIA 2 MTRS 955.02
(E) 25MM DIA 3 MTRS 550.85
NOTE: - LENGTHS MAY VARRY ACCORDING TO ASSEMBLY /
LOCATION OF PUMPS.
C EXTERNAL HYDRANT & FIRE BRIGADE TANKER INLET
C1 4 WAY FIRE BRIGADE INLET : -
PROVIDING AND FIXING OF 4 WAY FIRE BRIGADE INLET
CONNECTIONS MADE OF CI BODY, 150MM DIA FLANGED INLET
WITH 4 NOS OF INBUILT SS, NRV (BODY TYPE) WITH PVC BLANK 1 NOS
(MAKE:- AAAG / NEWAGE)
C2 2 WAY FIRE BRIGADE INLET : -
DESCRIPTION Qty. UNIT AMOUNT
PROVIDING AND FIXING OF 2 WAY FIRE BRIGADE INLET
CONNECTIONS MADE OF CI BODY, 100MM DIA FLANGED INLET
WITH 2 NOS OF INBUILT SS, NRV (BODY TYPE) WITH PVC BLANK 3 NOS
(MAKE:- AAAG / NEWAGE)
C3 BUTTERFLY VALVE :-
PROVIDING AND FIXING OF BUTTERFLY VALVE WITH MS
FLANGES, GI NUT, GI BOLT, GI WASER & RUBBER GASKET ETC.
COMPLETE AS REQUIRED.
(MAKE:- ZOLOTO / SANT)
(A) 100MM DIA (FOR 2 WAY VALVE) 2 NOS 5,200.00
(B) 150MM DIA (FOR 4 WAY VALVE) 1 NOS 5,790.32
C4 C.I. DUAL PLATE NON-RETURN VALVE :-
PROVIDING AND FIXING OF C.I. DUAL PLATE NON-RETURN VALVE
WITH MS FLANGES, GI NUT, GI BOLT, GI WASER
& RUBBER GASKET ETC. COMPLETE AS REQUIRED.
(MAKE:- ZOLOTO / SANT)
(A) 100MM DIA (FOR 2 WAY VALVE) 2 NOS 6,350.00
(B) 150MM DIA (FOR 4 WAY VALVE) 1 NOS 7,991.24
SUPPLY, INSTALLATION, TESTING & COMMISISONING OF
G.I. "C" CLASS PIPE AS PER IS 1239 WITH PAINTING
(1 COAT OF ZINC OXIDE PRIMER AND 2 COATS OF PO RED PAINT),
SUITABLE TYPES OF SUPPORTS, HILTI FASTENERS, BOLTS, NUTS
(GALVANISED), CLAMPS, "U" BOLTS, FITTINGS SUCH AS
REDUCERS, TEES, ELBOWS, FLANGES. INCLUDING CUTTING,
WELDING, FIXING IN/ON WALLS, CEILING BY USING SUITABLE
(A) 150MM DIA 128 MTRS 2,445.74
(B) 100MM DIA 24 MTRS 1,800.00
(C) 80MM DIA 12 MTRS 1,700.00
NOTE: - LENGTHS MAY VARRY ACCORDING TO ASSEMBLY /
LOCATION OF PUMPS.
D PRESSURISED WET RISER SYSTEM
D1 BUTTERFLY VALVE :-
PROVIDING AND FIXING OF BUTTERFLY VALVE WITH MS
FLANGES, GI NUT, GI BOLT, GI WASER & RUBBER GASKET ETC.
COMPLETE AS REQUIRED.
(MAKE:- ZOLOTO / SANT)
(A) 100MM DIA 2 NOS 5,200.00
D2 FORGED BRASS BALL VALVE :-
PROVIDING AND FIXING OF FORGED BRASS BALL VALVE
SCREWED END (SUITABLE FOR WORKING PRESSURE
(MAKE:- ZOLOTO / SANT)
(A) 25MM DIA (FOR RISER DRAIN) 2 NOS 830.51
(B) 25MM DIA (FOR AIR RELEASE VALVE) 2 NOS 830.51
(C) 20MM DIA (FOR HOSE REEL TAPPING) 6 NOS 578.03
D3 FORGED BRASS AIR RELEASE VALVE :-
PROVIDING AND FIXING OF FORGED BRASS AIR RELEASE VALVE
SCREWED END. (SUITABLE FOR WORKING PRESSURE OF
(MAKE:- ZOLOTO / SANT)
(A) 25MM DIA 2 NOS 1,822.03
DESCRIPTION Qty. UNIT AMOUNT
SUPPLY, INSTALLATION, TESTING & COMMISISONING OF
G.I. "C" CLASS PIPE AS PER IS 1239 WITH PAINTING
(1 COAT OF ZINC OXIDE PRIMER AND 2 COATS OF PO RED PAINT),
SUITABLE TYPES OF SUPPORTS, HILTI FASTENERS, BOLTS, NUTS
(GALVANISED), CLAMPS, "U" BOLTS, FITTINGS SUCH AS
REDUCERS, TEES, ELBOWS, FLANGES. INCLUDING CUTTING,
WELDING, FIXING IN/ON WALLS, CEILING BY USING SUITABLE
(A) 100MM DIA 24 MTRS 1,800.00
(B) 80MM DIA (FOR HYDRANT BRANCHING) 2 MTRS 1,700.00
D5 HYDRANT VALVE :-
PROVIDING AND FIXING OF SS-304 SINGLE OUTLET
FIRE HYDRANT VALVE, HAVING 63MM FEMALE OBLIQUE TYPE
AND 80MM FLANGED INLET, AS PER IS:5290, 10 NOS
ISI MARKED WITH ABS BLANK CAP AND GI CHAIN.
D6 FRP AAAGDOUBLE
SHEETED / NEWAGE)
DOOR HOSE BOX 10 NOS 3,079.13
D7 HOSE REEL DRUM SET :-
SUPPLYING AND INSTALLING TESTING AND COMMISSING OF
WALL MOUNTING SWINGING HOSE REEL DRUM AS PER IS
AND FITTED WITH 20MM DIA X 30METER LONG HIGH PRESSURE
RUBBER HOSE PIPE WITH S.S. SHUT OFF NOZZLE WITH
NECESSARY MS BRACKET FOR HOLDING HOSE REEL DRUM.
(MAKE :- AAAG / NEWAGE)
D8 HOSE PIPE :-
PROVIDING AND FIXING OF RRL FIRE HOSE OF 63MM DIA X 15
METER AS PER IS:636, TYPE-A, ISI MARKED WITH SS-304, 63MM
MALE & FEMALE COUPLING AS PER IS:903, ISI MARKED BANDED 20 NOS
WITH COPPER WIRE.
(MAKE:- AAAG / NEWAGE)
D9 HEXAGONAL NOZZLE :-
PROVIDING AND FIXING OF SS-304, 63MM X 20MM SHORT 10 NOS 1,652.54
BRANCH PIPE WITH NOZZLE AS PER IS:903, ISI MARKED.
(MAKE:- AAAG / NEWAGE)
E1 50% MAP ABC TYPE FIRE EXTINGUISHER :-
(A) 6KG CAPACITY 12 NOS 3,059.32
(MAKE:- SAFEX / KANEX / V-SAFE)
E2 CO2 TYPE FIRE EXTINGUISHER :-
(A) 4.5KG CAPACITY 12 NOS 8,127.12
(MAKE:- SAFEX / KANEX / V-SAFE)
E3 MODULAR TYPE AUTOMATIC FIRE EXTINGUISHER :-
(A) 5KG CAPACITY (FOR METER ROOM) 2 NOS 2,656.50
(MAKE:- SAFEX / KANEX / V-SAFE)
F FIRE ALARM SYSTEM
F1 FIRE ALARM PANEL :-
2 LOOP ADDRESSABLE TYPE FIRE ALARM PANEL WITH BATTERY
(MAKE:- MORLEY BY HONEYWELL)
F2 MANUAL CALL POINT :-
ADDRESSABLE TYPE MANUAL CALL POINT WITH BASE. 6 NOS 3,562.13
(MAKE:- MORLEY BY HONEYWELL)
F3 SOUNDER STROBE :-
ADDRESSABLE TYPE SOUNDER STROBE WITH BASE. 6 NOS 6,762.00
(MAKE:- MORLEY BY HONEYWELL)
DESCRIPTION Qty. UNIT AMOUNT
F4 SMOKE DETECTOR :-
ADDRESSABLE TYPE SMOKE DETECTOR WITH BASE. 30 NOS 1,968.23
(MAKE:- MORLEY BY HONEYWELL)
F5 FAULT ISOLATOR :-
ADDRESSABLE TYPE FAULT ISOLATOR WITH BASE. 4 NOS 3,079.13
(MAKE:- MORLEY BY HONEYWELL)
F6 COPPER ARMORED CABLE :-
(A) 2 CORE X 1.5 SQ.MM. 1500 MTRS 101.69
(MAKE:- POLYCAB/RR CABLES/KEI)
(NOTE:- CABLE LENGTH MAY VARRY TENTATIVE)
NIGHT GLOVE SIGNAGES ON 3MM PVC FOAM SHEET.
(A) FIRE EXTINGUISHER (5 X 5 = 25 SQ.INCH X 12 NOS) 300 SQ. INCH 6.78
(B) FIRE HOSE REEL (5 X 5 = 25 SQ.INCH X 6 NOS) 150 SQ. INCH 6.78
(C) EMERGENCY EXIT (12 X 4 = 48 SQ.INCH X 6 NOS) 288 SQ. INCH 6.78
(D) FIRE PUMP (12 X 4 = 48 SQ.INCH X 3 NOS) 144 SQ. INCH 6.78
(E) FIRE PUMP PANEL (12 X 4 = 48 SQ.INCH X 1 NOS) 48 SQ. INCH 6.78
(F) MANUAL CALL POINT (5 X 5 = 25 SQ.INCH X 6 NOS) 150 SQ. INCH 6.78
(G) HOOTER (5 X 5 = 25 SQ.INCH X 6 NOS) 150 SQ. INCH 6.78
(H) FIRE ALARM PANEL (12 X 4 = 48 SQ.INCH X 1 NOS) 48 SQ. INCH 6.78
EXECUTIVE ENGINEER
NEW EAST (SARTHANA) ZONE
SIGNATURE OF CONTRACTOR SURAT MUNICIPAL CORPORATION
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
W.N. 02 Tech Bid Valak Reading Room and Health Club.pdf
W.N. 02 Price Bid Valak Reading Room and Health Club.pdf
Valak Reading Room and Health Club FIRE FIGHTING SYSTEM DETAILS SPECIFICATION.pdf
01_SITE DEVELOPMENT LAYOUT.pdf
Download all tender documents and submit your bid