Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC KALYANESWARI PASCHIM BARDHAMAN WEST BENGAL | KALYANESWARI | PASCHIM BARDHAMAN | WEST BENGAL | L1 | Accepted-AOC lowest | |
| 2 | L2₹49.6 L+₹12,100.35 (0.24%)Rejected-AOC NAMOPARA PURULIA | PURULIA | PURULIA | WEST BENGAL | 723101 | L2 | Rejected-AOC 2nd lowest | |
| 3 | L3₹49.7 L+₹26,027.72 (0.53%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
25 Nov 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer, PMD,PHE.Dte
Office of the Executive Engineer Purulia Mechanical Division,PHE.Dte Ranchi Road,Purulia.
Supply delivery and installation of centrifugal pumping machineries, MCC panel, Flowmeter with necessary substitutes and allied works at WTP area of Jhalda Augmentation w/s project under PMD, PHE Dte. in the District of Purulia.
2022_PHED_419229_9
15/ EE/PMD/PHED OF 2022-2023
Open Tender
MECHANICAL
Item Rate
60 days
Purulia
Please refer Tender documents.
6 documents required · 6 mandatory
₹1.1 L
Yes
23 Mar 2023
4 Nov 2022
28 Nov 2022
4 Nov 2022
25 Nov 2022
4 Nov 2022
Amount
PART A
Supply and delivery at site horizontal split casing centrifugal pump set capable of discharge against total head and mounted RCC base plate coupled with squirrel cage induction motor operated on 415V, 3 split phase + 10% , 3 phase 50 hz AC supply having speed 1475 rpm ( pump and motor design approved by the depertment ) with supply of all accessories to complete the pumping operation. Description and parameters of the pump . Manufacturing Standerd - IS : 6595(part 1) & IS:5120 / Relevent IS Testing Standard : IS:9137(C) /Relevent IS Discharge Capacity (CMH) - 120 Total Head(MTR) - 40 Rated Speed - 1475 Pump Efficiency - 73 and above MOC of the Pump Pump Casing - CI, FG-260, IS:210 Impeller - BR Shaft - SS410 ,Type of packing - Gland Packing Base Plate- MS Fabircted Manufacturing Standerd - IS : 325 / Relevent IS for energy efficient motor,Testing Standard : IS : 325 / Relevent IS for energy efficient motor Rating - 22KW / 30 HP , Type - Horizontal foot mounted, solid shaft squirrel cage induction motor Voltage- 415V + 10% Frequency - 50 Hz + 5% No of phase - 3 Speed - 1500 (SYNC) Efficiency Class- IE-3 Duty- S1 Degree Of protection- IP55 Design Ambient Temporature- 50 Degree C Cooling- IC411 Acessories- Base frame , Coupling, coupling gourd, foundation Bolt (Make- Kirloskar/CG/WPIL) (MOC, Test Certificate, warranty certificate along with charcteristic curve to be produced at the time of delivery ) (Meterial should be supplied after taking the approval from the dept at the time of delivery ) (All routine test to be performed in presence of EIC before delivery ). At H.L pump house.
Supply and delivery at site horizontal split casing centrifugal pump set capable of discharge against total head and mounted RCC base plate coupled with squirrel cage induction motor operated on 415V, 3 split phase + 10% , 3 phase 50 hz AC supply having speed 1475 rpm ( pump and motor design approved by the depertment ) with supply of all accessories to complete the pumping operation. Description and parameters of the pump . Manufacturing Standerd - IS : 6595(part 1) & IS:5120 / Relevent IS Testing Standard : IS:9137(C) /Relevent IS Discharge Capacity (CMH) - 15 Total Head(MTR) - 35 Rated Speed - 1475 Pump Efficiency - 61% and above MOC of the Pump Pump Casing - CI, FG-260, IS:210 Impeller - BR Shaft - SS410 ,Type of packing - Gland Packing Base Plate- MS Fabircted Manufacturing Standerd - IS : 325 / Relevent IS for energy efficient motor,Testing Standard : IS : 325 / Relevent IS for energy efficient motor Rating - 3.5KW / 5 HP , Type - Horizontal foot mounted, solid shaft squirrel cage induction motor Voltage- 415V + 10% Frequency - 50 Hz + 5% No of phase - 3 Speed - 1500 (SYNC) Efficiency Class- IE-3 Duty- S1 Degree Of protection- IP55 Design Ambient Temporature- 50 Degree C Cooling- IC411 Acessories- Base frame , Coupling, coupling gourd, foundation Bolt (Make- Kirloskar/CG/WPIL) (MOC, Test Certificate, warranty certificate along with charcteristic curve to be produced at the time of delivery ) (Meterial should be supplied after taking the approval from the dept at the time of delivery ) (All routine test to be performed in presence of EIC before delivery ). At H.L pump house (OHR for inside the pump house)
Supply and delivery at site of 1.1KV grade 16 sq mm XLPE insulated 3 core unarmoured copper cable as per IS 7098 Part-1 (Make: Havels/ Gloster/ Polycab /NICCO) (FOR HL CENTRIFUGAL PUMPS) (Materials should be supplied as per requirement of site, no extra material will be received by the department.)(Materials should be supplied as per requirement of site, no extra material will be received by the department.)
Installation testing and commissioning of centrifugal pumping machinery by Dismantling of the existing not functioning pump motor set ( if needed) with connection of all cable making masonry RCC pump motor base foundation, suction line, delivery line, common header, including supply of all erection materials, pipe support, reducer, enlarger, expansion joint, valve support, earthing materials, cable tray etc. as required. Laying of cable, connection with MCC panel of centrifugal pumping machineries, and other electrical items , and cable connection from CWR site pump house to submersible pump house with supply of gland & other and completion as per direction of EIC and IE rules to complete net finishing of the whole installation. Rate is including hire charges of Generator, welding set, fuels, lubricants & Gland to complete the job as per relevant IS. (Any item or accessories not considered in the specification but required to complete the entire installation and operation shall have to be supplied and installed. No extra charge shall be provided for this purpose.)
PART B
Supply & delivery of MCC panel with compartment wise construction ;floor mounted made of sheet steel fabricated 2mm,indoor type, dust vermin proof,IP-54degree protection CPRI approved, powder coated painted with rubber gaskets cover, front lockable hinged door,Elctrolytic grade tinned copper busbar fittings complete with all switchgear and other items duly wired up, TPN electrolyte grade LT panel on frp insulators, detachable gland plate at bottom and tested as per specification.(BOQ attached) at high lift pump house
Installation and commissioning of above mentioned MCC Panel by making required size masonary cable trench and necessary foundation with supplying required no. compression gland, socket, cable lug, MS chequers sheet, channel ,angle earthing 50mm x 6mm GI stripe for earthing connection etc. by expert electrician and electrical supervisor to complete the job upto satisfaction of EIC. Double earthing should be provided in all equipments (including All pumps motors) connected with 400± 10% volt and single earthing should be provided in rest of all equipments. (Any item or accessories not considered in the specification but required to complete the entire installation and operation shall have to be supplied and installed. No extra charge shall be provided for this purpose.)
Excavation of earth for installion of earth electrode and filling and ramming a)for soft soil
Earthing with 65mm dia GI pipe (tata-medium)x3.0Mts. long and 50x6mm galvanised(Hot dip) steel strip(4mtr long) standard GI(Hot Dip) wire,20mm dia x 125mm long galvanized bolt,double nuts ,double washers including finishing both ends by making holesetc. and S&F 65mm dia GI pipe(ISI-medium) protection (3Mts)longto be filled with bitumen partly under the ground level; and partly above ground level to an average depth 3.65mtrs.
supply and fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 6mm on wall having clearence of 6mm from wall including providing drilled holes on the busbar complete with GI bolts,nuts,washers with earthing
Extra for providing masonery enclosure on the top of the earth electrode of over all size 86.36 cm x 86.36 cm x 46 cm deep ( below the ground level ) complete with cemented bricks work (1:6) of 25 cm width duly plasterd with cement morter (inside) CI hinged inspection cover size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos 12 mm dia holes on the GI pipe.
PART C
Supply Delivery of Electromagnetic Flow Meter 250 mm dia on rising main at premises ,specification as per SOQ of NIT
MS dismantling joints with Rubber Compression Ring and adjustable follower flanged complete assembled unit with galvanized stud and nuts. PN-1.0, 250 mm
Installation of above supplied flowmeter on rising main pipe line by cutting existing pipe, chamfering, fitting with proper allignment with by expart personnel by supplying all required auxiliries, short piece pipe to complete the job as per direction of EIC
Making suitable size flowmeter foundation guard 1mtr x 1mtr as required dimension with supplying of necessary cement, brick sand and stone chips including plastering and net cement finish complete masonery work and hinge MS fabricated top gate with locking arrangement as per direction of EIC
Add GST @ 18%
Add CESS @ 1%
COMBINE ENTERPRISES
TAPAN KUMAR DEY
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .