Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC 4 A RUKSHMANI PARK SOCIETY OPP SAMA WATER TANK NEW SAMA ROAD VADODARA 390 008 | VADODARA | VADODARA | GUJARAT | 390008 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹14.8 L+₹1.2 L (9.12%)Rejected-AOC G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA GUJARAT 390002 | VADODARA | VADODARA | GUJARAT | 390002 | L2 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
6 Feb 2023, 6:00 pmClosed
Sachin Singhal EE GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2023_MES_573654_1
8704
Open Tender
Civil Works
Item Rate
180 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹30,000
Yes
31 Mar 2023
7 Jan 2023
13 Feb 2023
7 Jan 2023
6 Feb 2023
19 Jan 2023
8 Jan 2023 - 18 Jan 2023
Amount
Labour only for taking out of non clogging type submersible sewage pump set 7.5 HP capacity with the help of chain pully block mechanism complete including dismantlling for replacement of following accessories including lowering, reinstalling in same position after servicing, oiling, greasing and testing complete. Note : Chain pulley bolck shall be provided by contractor.The parts replaced will be paid at relevant items.
Labour only for taking out of non clogging type submersible sewage pump set 5 HP capacity with the help of chain pully block mechanism complete including dismantlling for replacement of following accessories including lowering, reinstalling in same position after servicing, oiling, greasing and testing complete. Note : Chain pulley bolck shall be provided by contractor.The parts replaced will be paid at relevant items.
M & L for rewinding of motor of 7.5 HP of non clogging type submersible sewage pump set with suitable gauge super enamelled copper winding wire duly coated with insulating varnish & using other insulating material including testing complete.
M & L for rewinding of motor of 5 HP of non clogging type submersible sewage pump set with suitable gauge super enamelled copper winding wire duly coated with insulating varnish & using other insulating material including testing complete.
M & L for rubber gasket for pump 5 HP & 7.5 HP.
M & L for double seal bearing for 7.5 HP pump set , set of two as per sample.
M & L for double seal bearing for 5 HP pump set, set of two as per sample.
M & L for Mechanical seal complete with oil for 7.5 HP & 5 HP Pump set.
M & L for Bronze impeller with cutter suitable for 7.5 HP Pump set.
M & L for Bronze impeller with cutter suitable for 5 HP Pump set.
M & L for Oil seal for 7.5 HP & 5 HP pump set as per sample
S & F Green suction hose pipe medium duty ISI marked of size 50 mm inner dia with wall thickness not less than 5.0 mm suitable for working pressure 6.0 Kg/ Sq cm & bursting pressure 13.0 Kg/ Sq cm complete.
S & F cast iron bends (any type, radius & angle), tapers any type (Straight bend increasing or decreasing or double socket etc) tee pieces single branch 'Y' junction double branch cross (all socket or socket & spigot) collars caps plug etc upto 150 mm bore for spigot & socket and socket pipes as per IS 1538.
S&F 150mm bore CI sluice valve both ends flanged class PN-1.6 with stainless steel spindle including joints & jointing materials (Rubber gasket, nut, lts,washers etc) complete including taking down old u/s sluice valve all as specified and directed.
S&F 100mm bore CI sluice valve both ends flanged class PN-1.6 with stainless steel spindle including joints & jointing materials (Rubber gasket, nut, lts,washers etc) complete including taking down old u/s sluice valve all as specified and directed.
S&F 80mm bore CI sluice valve both ends flanged class PN-1.6 with stainless steel spindle including joints & jointing materials (Rubber gasket, nut, lts,washers etc) complete including taking down old u/s sluice valve all as specified and directed.
M&L for framed work such as grills, gratings etc with ends of bars, shouldered and/or riveted or forged into spikes framed guard bars, barred iron doors, ladders, chequte plate framed balusters, walkways, railing, framework of water tanks and similar work conforming to Fe-290 Gde E-165. in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed.
M & L for Construction of brick masonary valve pit chamber complete of size 1200 mm X 1200 mm X 1200 mm(internal dimension) with cover made of 3 mm thick sheet with MS angle iron frame of size 50x50x6mm with locking arrangement, PCC, plastering etc all as per TD/2004/26(TD can be referred at GE office) including necessary excavation & earth work in any type of soil and two coats of anti corrosive paint over one coat of zinc chromate primer ove steel surfaces complete.
Supply and fixing stainless steel frame work for sign board ( grade of steel 304) made of hollow tubes , plates etc including welding griding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including accessories required for fixing & stainless steel dash fastner , stainless steel bolt etc of required size on the top of floor or the side of the waist slab with suitable arrangements as per specified and directed alongwith Manufacturing, supply and installation of full poly carbonate micro prismatic type retro reflective boards confirming to IS XI of ASTM, made of 4 mm thick substrate of aluminium composite panel having 0.50 mm thick skin of aluminium on both sides. Both side to be covered with full poly carbonate prismatic reflective sheeting confirming to proposed type XI ASTM with coloured scheme , including boarders as per IRC 67-2001. The aluminium composite panel shall be suitable fixed on top, bottom and sides of stainless steel frame work including supplying and fixing complete. The installation informatory sign board of size 6 to 8 ft x 2.5 ft to 3 ft width, overall hight of board shall be 5 mtr from floor/ground level and fixed on wall /roof any size with stainless steel tubes of required size with nut/bolts or grounting in PCC complete and writting letters for installation name, area MES logo as per direction/sample etc. The letter/pictures are duly printed on high intensity retro reflector grade sheeting of white colour on base of board dark blue colour, duly computerized cut, fixed with suitable adhesive in English capitals as specified and directed by Engr -in - charge at site. including complete with lighting arrangements, fixed inside using LED tube light or similar LED lights which glow the board at night Makes of tube light are Crescent /Halonix/Phillips with complete necessary wiring of 1.5 mm2 single core PVC insulated copper stranded conductor cable and fixed in ground or on walls in PCC Type D2 in 1:4:8 using 40 mm graded stone aggregate etc and testing for smooth functioning, all as entire satisfaction of Engr-in-Charge.
M& L for collection of drinking water sample as per laboratory guidelines from pump house and carrying out followings laboratory test as per IS from any of the Engg College ,Central Govt , state govt. or any of the Govt recognized (ISO / IEC 17025 Accerdited Testing Laboratory by NABL) lab all as directed by Engr-in-Charge. (a) Physical Examination/Test (b) Chemical Examination/Test
Supply only Chloroscope Chlorine test kit complete comprises of (a) two test tubes (b) Ortho- tolodine Regent for water testing 50 ml (c ) Matching Glass strip (d) Droper (e ) Two additional Ortho- tolodine Regent for water testing 500 ml Each
M&L for earthing complete with GI steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanised iron strip 25×4mm upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 5 of MES SSR part I & testing on completion including necessary excavation and earth work in any type of soil strata, PCC (1:3:6) type C1 chamber, with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,medium grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
M & L replacement of weather proof flexible copper conductor submersible cable of size 6 Sqmm as per suitable for 3-phase submersible sewage pump, PVC/Rubber un-sheathed, unarmoured suitable for submersible sewage pump complete.
General servicing of following DG set including cleaning of machines, fuel tank etc checking of oil levels, filters, fan belts, hose pipe, proper adjustment of tappet, checking of governor assembly, radiator complete all as per manufacturers recommendations including replacement of Fuel filter, Engine oil filters, etc complete as per direction of Engr-in-Charge. Note :- Engine oil & Coolant wii be measured and paid separately under subsequent items
100 KVA ( Make- Kirloskar / Mahindra & Mahindra / Ashok Leyand )
62.5 / 63 KVA ( Make- Ruston / Kirloskar / Greaves / Mahindra / Ashok Leyand / Sudhir / CG )
30/35 KVA ( Make- Ruston / Kirloskar / Greaves / Mahindra / Ashok Leyand / Sudhir / CG )
Repairs to DG set engine of capacity 62.5 / 63 KVA / 30/35 KVA any make, 6 cylinder, 1500 RPM, water cooled by dismantling/strip opening of the DG set for top overhauling by removing the cylinder heads, piston, connecting rod, cylinder liner, oil sump and injector etc including calibration of engine and reassembling of the complete engine as per the manufacturer instruction and testing of efficiency of engine on completion complete all as directed. (worn out / unserviceable parts shall be measured and paid seperately as under)
Piston assembly as per existing model complete all as directed
Ring set as per existing model complete all as directed.
Cylinder liner as per existing model complete all as directed
Set of liner 'O' ring as per existing model complete all as directed
Gasket set kit as per existing model complete all as directed
Coupling as per existing model complete all as directed
Gasket (Main Seal) as per existing model complete all as directed
Diesel Pipe Set as per existing model complete all as directed
Hose Pipe as per existing model complete all as directed
Hose Clamp as per existing model complete all as directed
Cylinder head gasket as per existing model complete all as directed
Cylinder head 'O' Ring as per existing model complete all as directed
Valve set as per existing model complete all as directed
Valve seal as per existing model complete all as directed
Valve guide as per existing model complete all as directed
Connecting rod bearing as per existing model complete all as directed
Connecting rod bush as per existing model complete all as directed
Fan Belt as per existing model & size complete all as directed
Repairs to DG set engine of capacity 100 KVA any make, 6 cylinder, 1500 RPM, water cooled by dismantling/strip opening of the DG set for top overhauling by removing the cylinder heads, piston, connecting rod, cylinder liner, oil sump and injector etc including calibration of engine and reassembling of the complete engine as per the manufacturer instruction and testing of efficiency of engine on completion complete all as directed. (worn out / unserviceable parts shall be measured and paid seperately)
Piston assembly as per existing model complete all as directed
Ring set as per existing model complete all as directed.
Cylinder liner as per existing model complete all as directed
Set of liner 'O' ring as per existing model complete all as directed
Gasket set kit as per existing model complete all as directed
Coupling as per existing model complete all as directed
Gasket (Main Seal) as per existing model complete all as directed
Diesel Pipe Set as per existing model complete all as directed
Hose Pipe as per existing model complete all as directed
Hose Clamp as per existing model complete all as directed
Cylinder head gasket as per existing model complete all as directed
Cylinder head 'O' Ring as per existing model complete all as directed
Valve set as per existing model complete all as directed
Valve seal as per existing model complete all as directed
Valve guide as per existing model complete all as directed
Connecting rod bearing as per existing model complete all as directed
Connecting rod bush as per existing model complete all as directed
Fan Belt as per existing model & size complete all as directed
Taking out FIP from DG set, transportation to authorized service centre for overhauling and re-caliberation and re-fixing to DG set complete all as specified and directed of capacity DG Set 100 KVA Make - Crompton Greaves / Kirloskar complete all as directed:- (Unserviceable / defective parts shall be measured and paid seperately)
Injector as per existing model complete all as directed
Injector Nozzle as per existing model complete all as directed
Delivery valve as per existing model complete all as directed
FIP Element as per existing model complete all as directed
Gevernor as per existing model complete all as directed
Taking out FIP from DG set, transportation to authorized service centre for overhauling and re-caliberation and re-fixing to DG set complete all as specified and directed of capacity DG Set 62.5 / 63 / 35 / 30 KVA Make - Crompton Greaves / Kirloskar complete all as directed:- (Unserviceable / defective parts shall be measured and paid seperately)
Injector as per existing model complete all as directed
Injector Nozzle as per existing model complete all as directed
Delivery valve as per existing model complete all as directed
FIP Element as per existing model complete all as directed
Gevernor as per existing model complete all as directed
S&F Automatic voltage regulator (AVR) suitable for 63 KVA to 100 KVA DG Set in replacement of defective / unserviceableAVR complete all as directed. Make - Kirloskar/CG
S&F Automatic voltage regulator (AVR) suitable for 35 KVA DG Set in replacement of defective / unserviceableAVR complete all as directed. Make - Kirloskar/CG
S&F Alternator / Dynamo 12 volt 30 to 100 KVA DG Set, as per existing model in replacement of defective / unserviceable alternator complete all as directed
S&F Stop Solenoid any make, type and capacity as per existing model in eplacement of defective / unserviceable stop Solenoidcomplete all as directed
Strip opening of alternator of capacity 100 KVA, removing rotor from the starter and rewinding to CT coils complete with super enamel copper winding wire of appropriate size including insulating material and replacing Rear and front bearing including greasing of the alternator and refixing with engine and complete testing and refixing all components of the alternator and mounting the same on the existing foundation including aligning the alternator with engine and testing on full load as specified in particular specification and as directed
Strip opening of alternator of capacity 62.5 / 63 / 35 / 30 KVA, removing rotor from the starter and rewinding to CT coils complete with super enamel copper winding wire of appropriate size including insulating material and replacing Rear and front bearing including greasing of the alternator and refixing with engine and complete testing and refixing all components of the alternator and mounting the same on the existing foundation including aligning the alternator with engine and testing on full load as specified in particular specification and as directed
S&F RPM meter/ hour meter 90 mm dia auto indicate speed of the engine from 0-2500 RPM and hours run in replacement of defective / unserviceable RPM meter complete with cable and adopter.
S&F self starter for 63 / 62.5 KVA DG Set as per existing model in replacement of defective / unserviceable self starter complete all as specified and directed
S&F self starter for 100 KVA DG Set as per existing model in replacement of defective / unserviceable self starter complete all as specified and directed
S&F self starter for 35 KVA DG Set as per existing model in replacement of defective / unserviceable self starter complete all as specified and directed
Cleaning of radiator with the help of descaling agent/solution including repairs to the broken tubes and replacement of wornout rubber hoses for 35 KVA DG Set complete all as directed
Cleaning of radiator with the help of descaling agent/solution including repairs to the cracked tubes and replacement of wornout rubber hoses for 62.5 to100 KVA DG Set complete all as directed
S&F Air Filter for following capacity DG set of any model in replacement of defective / unserviceable Air filter complete all as specified and directed
100 KVA ( Make- Crompton Greaves / Kirloskar )
62.5 / 63 KVA ( Make- Crompton Greaves / Kirloskar )
35 KVA ( Make- Crompton Greaves / Kirloskar )
M& L for Engine Oil 20 W 40 or equivalent grade suitable for DG set at various locations. Make: Castrol/ Servo
Supply and filling concentrated coolant for radiator in 5 litre capacity container complete all as directed,
S & F battery of 12 V 180 AH suitable for DG set Make : Exide/ Amaron.
S&F in replacement of defective / unserviceable battery lead of copper conductor 25 sqmm, 3 mtr length, single core fitted with lead terminal on one side and other side with brass or lead terminal as per requirement and connection as directed
Servicing and Change of filter media (opening of plant replacement old UNsv filter Media) of complete filtration plant of swimming pool with cleaning of connected items like filter plant suction seaper, circulating pumps, alum dosing system, rotory twin blower for air application completeall as specified as directed For 01 lac gallon of water.
S & F Green suction hose pipe medium duty ISI marked of size 80 mm inner dia with wall thickness not less than 5.0 mm suitable for working pressure 8.0 Kg/ Sq cm & bursting pressure 15.0 Kg/ Sq cm complete.
M& L for rewinding of monoblock pump motor set of 7.5 HP of swimming pool with suitable gauge copper winding wire after taking out burnt winding wire varnishing. insulating mtrl etc complete all as specified as directed
M & L for caulking of lead joint of spigot and socket cast iron pipe incl providing lead wool and making joint leak proof including necessay earth work/excavation and making good disturbed site, T & P and draining out water etc of following as directed.
150 mm bore
100 mm bore
S & F in repair Gun metal gate valve iron wheel head screwed both ends for GI steel tubing suitable for 50 mm bore of pipe
S & F in repair Gun metal gate valve iron wheel head screwed both ends for GI steel tubing suitable for 40 mm bore of pipe
Supply only TCCA 90 (Trichloroisocyanuric Acid) in containers.
Supply only Alumn sulphate
Supply only copper sulphate
Supply only Bleaching powder min 25 % contained Chlorine
S&F nylon brush for suction sweeper as per sample as directed by Engr in Charge
S & F of on load changer switch in sheet steel enclosure four pole, 415volt, front handle operated of capacity 200 Amp complete, change over switch fixed in panels or on walls as per site requirement including taking down old UNSV change over switch any make and type all as specified and directed. Make- C & S Legrand / ABB / Havells
Supply, Installation and testing of Non clog vertical submersible pumps of size 7.5 HP, (600 lpm x 40mtr) flow and head with chrome steel impeller and cutter, non-clog to pass 40 mm size particles including Supply, installation with guide rail and lifting chain, cables, Earthing, testing complete all as specified and directed
Supply,installation and testing of Non cloging pump set, centrifugal type, IC diesel engine driven, of capacity 5 WHP (7.5 HP) inclusive of starter, mounted on four / two wheeled trolly & towing accessories with vehicle etc complete all as spcified and directed
City Light
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .