Assistant Project Engineer, KRFB
Office of the Chief Executive Officer, Kerala Road Fund Board (KRFB) T.C. 27/284, Sports Complex, Chandrasekharan Nair Stadium, Palayam, Thiruvananthapuram
Development of Smart Roads and Underground Ducting Including Utility Shifting of Power lines in ABD area Under Smart City Mission (PWD Roads under Phase 4B Package1 Electrical Works in Road ID 116 Rose House Panavila Road (Kalabhavan Mani Road)
2023_KRFB_582654_2
KRFB/571/2023-APE(CIVIL) - Ele
Open Tender
Electrical Works
Item Rate
60 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,500
Yes
₹50,000
Yes
Office of CEO KRFB
26 Aug 2023
1 Jul 2023
11 Jul 2023
1 Jul 2023
10 Jul 2023
1 Jul 2023
4 Jul 2023
Amount
PART A - Electrical works
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 25 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 150 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq.mm(57mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation90/75 mm or nearest size
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation110/94 mm or nearest size
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation120/102.5 mm or nearest size
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench63/50 mm or nearest size
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench77/63 mm or nearest size
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to under ground power cables with all required accessories in ground in the existing trench90/75 mm or nearest size
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench110/94 mm or nearest size
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench120/102.5 mm or nearest size
Supply, Testing, installation and commissioning of Metallic Feeder Pillar with 300 Amp LB SW on both ends 24 nos of O/G terminals ( Single Phase) with SFU TPN for giving service connections(16 Amps to 63 Amps as per requirements) provision for cable entry on both side, cable connecting facilities, phase indicators, volt meter and ammeter, danger labelling etc; Make: Subjected to approval from KSEB/KRFB
Earthing with G.I. earth pipe 3 metre long, 40 mm dia including accessories, and providing<br>masonry enclosure with cover plate having locking arrangement and watering pipe etc. with<br>charcoal/ coke and salt as required
Shifting of Single Phase connection on newly erected meter box, including supply of Single Phase Dust and Vermin proof and weather proof FRP meter box with 16 Amps cut out fuse and neutral link, earthing, wiring and other connection.
Shifting of Three Phase connection on newly erected meter box, including supply of Three Phase Dust and Vermin proof and weather proof FRP meter box with 32 Amps cut out fuse and neutral link, earthing, wiring and other connection
Shifting of Three Phase CT connection on newly erected meter box, including supply of Three Phase CT Dust and Vermin proof and weather proof FRP meter box with 32 Amps cut out fuse and neutral link, earthing, wiring and other connection
Supply and installation of 1.5 meter 32 mm Medium class earth pipe for Meter box Earthing
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4.06mm GI conductor (8SWG)
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 6 mm GI strip
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters
Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Astronomical time switch capable of following output in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status suitable for 3 output (1output per phase) and suitable for three phase supply
Supply, installation, testing and commissioning of cubical type LT panel suitable for 433 V, 3 Phase, 4 Wire 50 Hz supply system having surface area 0.945 sqmtr (450 x 450 x 300 mm)fabricated from CRCA sheet steel of 2 mm thick for frame work, cover and gland plates, with front opening, cleaning and finishing complete with 7 tank process for power coating, bottom base channel of MS section not less than 100 mm x 100 mm x 6 mm thick and supported on two pedestal of MS section not less than 100 mm x 100 mm x 6 mm thick and 2.5 meter long. The cubical shall be totally enclosed type with IP 65. The cubical is wired for accommodate Energy meter and Astronomical timer and shall be provided with FP 32 A FP MCB, 40 A FP Isolator, 6A Amp SP MCB, and LED Indicators. Work includes all work for foundation like excavation, PCC, brick work, plastering finishing etc and as per specification as required for fixing Astronomical timer and KSEB Energy meter
Providing and laying in existing trench HDPE Power Duct of OD 225mm. It shall have three concentric layers viz. outer layer, middle layer and inner layer with ribs. One coupler every 12 meter for duct jointing shall be provided. The coupler shall be used to join two HDPE pipes. It should either snap fit or Split type. The jointing shall meet the air pressure test of 2 Kg/cm2 for a minimum period of 2 hours. 2 End Plugs every 50 meters of pipe length shall be provided.<br>End Plugs shall be used to seal the end of ducts so as to prevent any ingress of water/dirt etc. The rate is inclusive of required specials and fittings wherever necessary laying should be as per design drawing technical specifications and directions of Engineer In charge<br>
Providing and laying in existing trench HDPE Power Duct of OD 160mm. It shall have three concentric layers viz. outer layer, middle layer and inner layer with ribs. The outer layer shall be made of HDPE material in red colour, middle layer shall be made of HDPE in translucent (natural) and the inner ribbed layer of solid permanent lubricant (PLB) i.e. Silicone. The inner surface of the multi channel ducts shall be straight ribbed & shall be of a configuration for faster installation of cables. 100% virgin HDPE raw material shall be used. No regrind shall be used and the duct shall be sourced from ISO 9001,14001, 18001 and ISRS audited manufacturer only. One coupler every 12 meter for duct jointing shall be provided. The coupler shall be used to join two HDPE pipes. It should either snap fit or Split type. The jointing shall meet the air pressure test of 2 Kg/cm2 for a minimum period of 2 hours. 2 End Plugs every 50 meters of pipe length shall be provided. End Plugs shall be used to seal the end of ducts so as to prevent any ingress of water/dirt etc. The rate is inclusive of required specials and fittings wherever necessary laying should be as per design drawing technical specifications and directions of Engineer in charge.
Providing and laying of 7- Way 40mm Multi Ducts with solid permanently solidly lubricated Silicone in inner layer for ICT fiber cables conforming to ASTMF 2160, ASTM D 2444 and /or equivalent Indian standard. External Sheath shall be in Orange Color and shall be free from visual defects like blisters, shrink holes, flaking, scratches, groove lines & surface roughness. The outer layer colour of the 7 nos. PLB HDPE ducts shall be Green, blue, yellow, Brown, violet, Grey , Red for differentiation, middle layer shall be translucent and the inner layer shall be having permanently lubricated lining of Silicone . Outer sheath thickness shall be 1.2mm 0.2mm. The inner surface of the multi channel ducts shall be straight ribbed & shall be of a configuration for faster installation of cables. Wall thickness(mm) of each of the ducts Excluding rib height shall be 2.9mm 0.3mm. Seven couplers every 100 meter for duct jointing shall be provided. The coupler shall be used to join two HDPE pipes. It should either snap fit or Split type. The jointing shall meet the air pressure test of 15 Kg/cm2 for a minimum period of 2 hours. 14 End Plugs every 100 meters of pipe length shall be provided. End Plugs shall be used to seal the end of ducts so as to prevent any ingress of water/dirt etc. testing and commissioning.<br>The rate is inclusive of required specials and fittings wherever necessary. ISO Requirements- ISO 9001, 14001, 18001 as per design drawing technical specifications and directions of Engineer in charge.<br>
Fathima Engineering Co. Pvt. Ltd.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_864797.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .