Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.4 LAdmitted-Finance A 6 MANDAWALI UNCHEPAR DELHI 110092 | SHAHDARA | DELHI | 110092 | -33.34% | ₹3.4 L | L1 | Admitted-Finance |
| 2 | L2₹3.5 LAdmitted-Finance C 344 GALI NO 2 BLOCK C WEST KARAWAL NAGAR DELHI 110094 | NORTH EAST | DELHI | 110094 | -31.52% | ₹3.5 L | L2 | Admitted-Finance |
Tender Value
₹5.1 L
EMD Value
₹10,199
Closing Date
18 Feb 2026, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
Supplying, Installation, Testing and Commissioning of various capacity Openwell Submersible/ Dewatering/ Monoblock Pump Sets at College of Art, 20-22, Tilak Marg, New Delhi.
2026_PWD_286784_1
232/EEE/PWDDHC,NDC2025-26
Open Tender
Electrical Works
30 days
New Delhi
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹10,199
28 Feb 2026
12 Feb 2026
18 Feb 2026
12 Feb 2026
18 Feb 2026
12 Feb 2026
Supplying, installation, testing and commissioning of horizontal openwell submersible pump set with CI impeller with motor suitable for operation on 415 volts, three phase, 50c/s AC supply and having under noted specifications complete with connection etc. as required. (a) Motor rating : 5.5 kw /7.5 HP Three phase (b) Pump inlet & Outlet size : 65 X 50 mm (c) Disdharge : 38000 LPH (d) Head : 30 mtrs
Supplying, installation, testing and commissioning of horizontal openwell submersible pump set with CI impeller with motor suitable for operation on 415 volts, three phase, 50c/s AC supply and having under noted specifications complete with connection etc. as required. (a) Motor rating : 3.7 kw /5.0 HP Three phase (b) Pump inlet & Outlet size : 60 X 50 mm (c) Disdharge : 24000 LPH (d) Head : 30 mtrs
Supplying, installation, testing and commissioning of Submersible non clog dewatering pump set with CI impeller with motor suitable for operation on 415 volts, three phase, 50c/s AC supply and having under noted specifications complete with connection etc. as required. (a) Motor rating : 2.2 KW /3.0 HP 1450 rpm (b) Capacity : 600 LPM (c) Head : 6 mtrs (d) Head range : 4 to 13 mtr (e) Discharge range : 150 to 750 LPM (f) Permissible Solid : 50 mm (g) Pump outlet : 80 mm
Supplying, installation, testing and commissioning of self priming Monoblock pumpset with CI impeller with motor suitable for operation on 220-240 volts, singke phase, 50c/s AC supply and having under noted specifications complete with connection etc. as required. (a) Motor rating : 0.75 kw (1.0 HP) (b) Capacity upto : 17000 LPH (c) Head uptp s. : 16 mtr (d) Speed (Nominal) : 2900 rpm (e) Suction & Discharge size : 7 mm
Supplying, installation, testing and commissioning of CRC indoor design Control Panel with three phase Starter for 5.5 kw /7.5 HP Three phase openwell submersible pump set, Main ON-OFF switches, overload relay, single phase preventor, float switch to prevent dry run, ammeter and voltmeter complete as required.
Supplying, installation, testing and commissioning of CRC indoor design Control Panel with three phase Starter for 3.7 kw /5.0 HP Three phase openwell submersible pump set, Main ON-OFF switches, overload relay, single phase preventor, float switch to prevent dry run, ammeter and voltmeter complete as required.
Providing & fixing of 3 x 4 sq.mm PVC insulated PVC sheathed flat water proof copper conductor submersible cable complete with connection, testing etc. complete as required.
Supplying, installation, testing & commissioning of following LED Post Top Lantern fitting made out of CRCA sheet, duly powder coated /Aluminium body, confirming to IP - 66, suitable for operation on 150 V to 270 V,(5500 to 6500K), 50 Hz AC Supply, having power factor ≥ 0.95, CRI > 80, Luminaries efficacy ≥ 80 lumen/watt , Driver efficiency > 85%, 10 kv surge protection, L-70 Life 50,000 burning hours. complete i/c dismentaling of existing fitting if any, connection, etc complete as reqd. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting).
LED Down lighter (COB Type) (System lumen efficacy ≥105 < 120 lm/Watt). Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector (a) 18 watt
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).(a) 100 watt
LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 50 watt
Less for credit of various capacity dismantled open well submersible pump set, dewatering pump set, monoblock pump set, starters etc. as per availability at site under buyback arrangement complete as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.05 MB
BOQ_379808.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid