Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC 176 SAINIK COLONY SANJAY NAGAR BAREILLY 243001 UP | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L1 | Accepted-AOC ok | |
| 2 | L2₹18.2 L+₹24,530 (1.37%)Rejected-AOC | L2 | Rejected-AOC ok | |
| 3 | Rejected-Technical | - | Rejected-Technical Not having required catagery a (ii) | |
| 4 | Rejected-Technical 695 NEAR ANJALI CLINIC SHIV PALACE SHANTI VIHAR BADAUN ROAD SUBHASH NAGAR BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | - | Rejected-Technical NO remarkas in WLR due to slow progress | |
| 5 | Rejected-Technical NEAR ANAJ MANDI SUBHASH NAGAR BAREILLY 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | - | Rejected-Technical Not having required catagery a (ii) |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
18 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY
Repair replacement to sewage line septic tank soak pit etc of Md Accn under AGE BR I at GE West Bareilly
2022_MES_514484_1
8036/C/E8
Open Tender
Civil Works
Works
180 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORY SCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRMSCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION O
6 documents required · 6 mandatory
₹500
Yes
₹94,000
Yes
23 Jul 2022
21 Mar 2022
20 Apr 2022
21 Mar 2022
18 Apr 2022
4 Apr 2022
21 Mar 2022 - 3 Apr 2022
60 days
Amount
Cleaning by taking out solid sludge / semi solid sludge / fluid sludge etc including sludge water from septic tank or manholes etc of any depth and removing and disposed off the same by hydraulic run section machine away from defence land complete all as specied and directed . Note:- Unit rate quated shall deemed to be included the following :- (i) Removing manhole covers carefully & refixing the same in existing position after cleaning complete. (ii) Two layer of bamboo matting laid over deposited sludge in pit. (iii) While measuring the item the depth of pit to be considered after settlement of water complete all as specified and directed by Engineer In Charge. (iv) Excavation and earth work in soft/loose soil, returning filling to excavated soil after laying of bamboo matt and spreading of bleaching powder and removing of surplus excavated soil to a distance not exceeding 50 mtr complete. (v) Bleaching powder @ 0.50 Kg/Sqm shall be sprinkled to pit for hygienic purpose.
Cleaning of chocked / blocked IWC / EWC / Nahani, floor or gully trap (Bathroom outlet/Kitchen outlet) in daily routine by manually on working day as per complaint lodged by user's or as directed by Engr-in-Charge.
Pumping out of water/liquid/sludge/any other waste/materials stagnated in septic tank/soak wells and discharge the same to nallah/drains through hose pipe upto distance of 250mtr, complete all as specified and directed by Engr -in - Charge.
Demolition of concrete (reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
M&L pre cast reinforced cement concrete 1:2:4 as in man hole covers or slab of septic tank etc type B-1 (20 mm graded agg) as in manhole cover set in cement mortar 1:6 complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia.
Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc.
M & L Brickwork with flyash bricks, straight or curved on plan to any radius i not half brick thick walls,built in CM 1:6 including brick work for seawage work.
M & L Brickwork with flyash bricks, straight or curved on plan to any radius i not half brick thick walls,built in CM 1:4
M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in cm 1:4 finished even and smooth without using extra cement,
Material & labour for preparing newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L preparation of New wall plaster surfaces and applying two coats of cement base paint over a coat of cement primer.
M&L extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds mitred stoped ends etc.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide & n.exc 1.5 m in depth for foundation etc or man holes etc n.exc 10 Sqm on plan & exc 1.5 m and n.exc 3.0m in depth & getting out in soft/loose soil complete all as specified and directed.
M&L for construction of soakage well incl all necessary form work 2.4M dia 3.0M effective depth including demolition of old soak pit as . All as specidied and directed by Engr in Charge.
Returning filling in incl spreading leveling and well ramming in layers n.exc 25 cm in soft/loose soil all as specified & directed
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above starting point all as specified & directed.
M & L Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate bed to drain pipes including packing under and haunching against the side of pipes after they are laid and tested for 150mm bore pipe.
M & L for Salt glazed stoneware drainl pipes 150mm bore grade A laid in trenches tested and jointed in cement mortar 1:1 with spun yarn complete all as specified and as directed.
Cutting in to existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 150 mm bore drain pipe.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories
S&F 100mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors floors all as specified
S&F in repairs 75mm dia Cast iron Nahani trap with steel grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4)
S&F75 mm bore. PVC(SWR) junction single (single T) equal or unequal with access door
S&F 75 mm bore PVC (SWR) pipes of single socketed in any length with rubber ring joints fixed to wall all as specified
S&F 75 mm bore. PVC (SWR) bends
S&F 75 mm dia PVC (SWR) bends any radius with access door
S&F 75 mm dia PVC (SWR) floor trap plain with greting incl jointing with solvent cement all as speicifed and directed by Engr in Charge.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall
S&F 110mm bore PVC (SWR) bends with oval access door all as specified
S&F 110 mm PVC (SWR) bend any radius
S&F 110mm bore.PVC(SWR) junction single (single T) equal or unequal with access door
multiple alliance enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .