Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹2.2 L+₹16,425.60 (8.26%)Admitted-Fee/PreQual/Technical/Finance | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | V BEST ENGINEERS L2 | AISHWARYA ELECTRICALS L1 |
|---|---|---|---|---|---|
| 1.00 | Renewal by Supply and fixing of 4Feet LED 20W Fitting with LED 20W tube (HigherEnd) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. | 15 | Nos. | 1,200 ₹18,000 | 1,100 ₹16,500 Lowest |
| 2.00 | Renewal by Supply and fixing of 1200mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp. | 10 | Nos. | 2,530 ₹25,300 | 2,300 ₹23,000 Lowest |
| 3.00 | Renewal by supply and fixing of 48W LED street light fitting with LED (Higher end) with 32 mm dia. GI pipe (class B) with 1 no. 32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting . | 3 | Nos. | 6,200 ₹18,600 Lowest | 6,200 ₹18,600 Lowest |
| 4.00 | Renewal by Supply and fixing of 5A / 15 A 3 Pin combined flush type wall socket with 15A flush type switch concealed in suitable TW box of size 8" X 6" X 3" in flush with wall and covered with 3 mm thick hylum sheet with painting. | 2 | Nos. | 660 ₹1,320 | 600 ₹1,200 Lowest |
| 5.00 | Renewal by Supply and fixing of 3Nos. 5A (3pin and 2pin) combined flush type wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with wall with earth connection (for computer plug socket) | 2 | Nos. | 660 ₹1,320 Lowest | 660 ₹1,320 Lowest |
| 6.00 | Renewal by Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour. | 50 | Mts | 300 ₹15,000 | 200 ₹10,000 Lowest |
| 7.00 | Renewal by Supply and fixing of 100A TPN sheet double break switch with HRC fuse and neutral on suitable angle iron frame work with earth connection only. | 1 | No. | 9,500 ₹9,500 | 9,000 ₹9,000 Lowest |
| 8.00 | Renewal by Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire with painting of suitable colour. | 73 | Mts | 630 ₹45,990 Lowest | 630 ₹45,990 Lowest |
| 9.00 | Renewal by Supply, erection, testing and commissioning of 1.5 TR (4000 K. cal/ hr) ABJ plastic split type Air conditioner conforming to IS: 1391 (Part-2) 1992 with Amdt No.1 to 2 fitted with compressor operating on non CFC refrigerant suitable for wall mounting for operation on 230V, 50 HZ single phase AC supply with 3 star rating as per BEE specification and capable of performing the functions of 1) Cooling
2) Dehumidifying
3) Air circulating
4) Filtering
The installation works for the above split type A.C units includes the following.
1. Mounting / Fitting indoor and outdoor units at their respective locations on suitable stand/frame.
2. Laying refrigerant copper pipe lines of (5/8" & 3/8") 3 meters length, including drilling holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm. 3. Installing the suction pipe with expanded polyurethelene foam 5mm thick tubing.
4) Laying 25mm dia PVC drain pipe of 6 mts. Length to drain out the condensate water being formed in the indoor unit.
5) Leakage testing the entire gas unit.
6) Charging refrigerant gas in the unit.
7) Suitable electric wiring to be provided with 3 core 2.5sq.mm PVC insulated copper wire between indoor and outdoor units up to 3 meters length and up to switch within 3 meters of location of indoor unit. | 1 | No. | 39,000 ₹39,000 | 35,000 ₹35,000 Lowest |
| 10.00 | Renewal by Supply and fixing of 4 KVA electronic automatic voltage stabilizer with input range of 170-270V and output range 200-240 V with high and low voltage cut off and 3 minutes time delay relay suitable for operation on 230V/50Hz single phase AC supply. | 1 | No | 4,200 ₹4,200 Lowest | 4,200 ₹4,200 Lowest |
Tender Value
₹2.0 L
EMD Value
₹2,000
Closing Date
25 Nov 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (Electrical), PWD, Trichy
Office of the Executive Engineer(Electrical), PWD, Electrical Division, Trichy
Renewal of powermains and cable arrangements to the X-ray and Lab in Government Hospital at Manachanallur in Trichy District.
2026_PWD_724332_1
TN No 6 2026-27 Dt 06.11.2026
Open Tender
Electrical Works
Item Rate
Manachanallur, Trichy
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹2,000
26 Nov 2026
10 Nov 2026
26 Nov 2026
10 Nov 2026
25 Nov 2026
10 Nov 2026
90 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Renewal by Supply and fixing of 4Feet LED 20W Fitting with LED 20W tube (HigherEnd) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. | 15 | Nos. | - | - |
| 2 | Renewal by Supply and fixing of 1200mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp. | 10 | Nos. | - | - |
| 3 | Renewal by supply and fixing of 48W LED street light fitting with LED (Higher end) with 32 mm dia. GI pipe (class B) with 1 no. 32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting . | 3 | Nos. | - | - |
| 4 | Renewal by Supply and fixing of 5A / 15 A 3 Pin combined flush type wall socket with 15A flush type switch concealed in suitable TW box of size 8" X 6" X 3" in flush with wall and covered with 3 mm thick hylum sheet with painting. | 2 | Nos. | - | - |
| 5 | Renewal by Supply and fixing of 3Nos. 5A (3pin and 2pin) combined flush type wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with wall with earth connection (for computer plug socket) | 2 | Nos. | - | - |
| 6 | Renewal by Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour. | 50 | Mts | - | - |
| 7 | Renewal by Supply and fixing of 100A TPN sheet double break switch with HRC fuse and neutral on suitable angle iron frame work with earth connection only. | 1 | No. | - | - |
| 8 | Renewal by Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire with painting of suitable colour. | 73 | Mts | - | - |
| 9 | Renewal by Supply, erection, testing and commissioning of 1.5 TR (4000 K. cal/ hr) ABJ plastic split type Air conditioner conforming to IS: 1391 (Part-2) 1992 with Amdt No.1 to 2 fitted with compressor operating on non CFC refrigerant suitable for wall mounting for operation on 230V, 50 HZ single phase AC supply with 3 star rating as per BEE specification and capable of performing the functions of 1) Cooling
2) Dehumidifying
3) Air circulating
4) Filtering
The installation works for the above split type A.C units includes the following.
1. Mounting / Fitting indoor and outdoor units at their respective locations on suitable stand/frame.
2. Laying refrigerant copper pipe lines of (5/8" & 3/8") 3 meters length, including drilling holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm. 3. Installing the suction pipe with expanded polyurethelene foam 5mm thick tubing.
4) Laying 25mm dia PVC drain pipe of 6 mts. Length to drain out the condensate water being formed in the indoor unit.
5) Leakage testing the entire gas unit.
6) Charging refrigerant gas in the unit.
7) Suitable electric wiring to be provided with 3 core 2.5sq.mm PVC insulated copper wire between indoor and outdoor units up to 3 meters length and up to switch within 3 meters of location of indoor unit. | 1 | No. | - | - |
| 10 | Renewal by Supply and fixing of 4 KVA electronic automatic voltage stabilizer with input range of 170-270V and output range 200-240 V with high and low voltage cut off and 3 minutes time delay relay suitable for operation on 230V/50Hz single phase AC supply. | 1 | No | - | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
BOQ_869572.xls
BOQ • 0.41 MB
142xray.pdf
Tender Documents • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .