Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC 22 1685 ST JACOB CHURCH LANE PAMBAIMOOLA EDACOCHIN ERNAKULAM KERALA 682010 | ERNAKULAM | ERNAKULAM | KERALA | 682010 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹9.2 L+₹1.4 L (18.2%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹9.5 L+₹1.7 L (21.5%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tender |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
26 Oct 2020, 6:00 pmClosed
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
AS PER BOQ AND TENDER DOCUMENTS
2020_MES_381444_1
8685/GEFK/E8
Open Tender
Civil Works
Item Rate
270 days
FORT KOCHI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE FORT KOCHI
₹20,000
Yes
17 May 2021
28 Sept 2020
31 Oct 2020
29 Sept 2020
26 Oct 2020
12 Oct 2020
29 Sept 2020 - 6 Oct 2020
Amount
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth and getting out in soft /loose soil complete all as specified.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth and getting out in hard / dence soil complete all as specified.
M & L Removing excavated soil to a distance not exceeding 50 meter and not exceeding 1.5 meter above the starting point, and depositing where directed complete all as specified.
M&L sand cushioning in trenches using clean dry river sand for cable cushioning all as specified and as directed. Note : Thickness of sand cushioning after punning down will be measured and paid.
Supply and lay /replacement of sub class "B" burnt bricks, as in cable protection, laid length of brick perpendicular to length of cable complete all as specified and directed.
M & L Returning and filling in of soil including spreading leveling, watering and ramming in layers not exceeding 25 cm complete all as specified.
M&L in replacement of XLPE insulated armoured heavy duty LT 1100 Volts grade with stranded aluminium conductor of C/S area of 16 Sqmm 4 Core in trenches/road crossing/on pole / wall etc including testing & connection, complete all as specified and directed
M&L in replacement of XLPE insulated armoured heavy duty LT 1100 Volts grade with stranded aluminium conductor of C/S area of 25 Sqmm 3.5 Core in trenches/road crossing/on pole / wall etc including testing & connection, complete all as specified and directed
M&L in replacement of XLPE insulated armoured heavy duty LT 1100 Volts grade with stranded aluminium conductor of C/S area of 50 Sqmm 3.5 Core in trenches/road crossing/on pole / wall etc including testing & connection, complete all as specified and directed
M&L in replacement of XLPE insulated armoured heavy duty LT 1100 Volts grade with stranded aluminium conductor of C/S area of 70 Sqmm 3.5 Core in trenches/road crossing/on pole / wall etc including testing & connection, complete all as specified and directed
M&L in replacement of XLPE insulated armoured heavy duty LT 1100 Volts grade with stranded aluminium conductor of C/S area of 95 Sqmm 3.5 Core in trenches/road crossing/on pole / wall etc including testing & connection, complete all as specified and directed
M&L in replacement of XLPE insulated armoured heavy duty LT 1100 Volts grade with stranded aluminium conductor of C/S area of 150 Sqmm 3.5 Core in trenches/road crossing/on pole / wall etc including testing & connection, complete all as specified and directed
Taking out existing LT UG Cables of any size from trenches / road crossing / panel / DBs for repairs including making good the disturbed surface of area.
Relaying of LT/UG cable, nominal cross section area of 10 to 70 Sqmm after carrying of repairs/jointing work, testing etc complete all as specified and directed. Note : Necessary joints, LT/UG cable, will be measured & paid seperately under relevant item in BOQ..
Relaying of LT/UG cable, nominal cross section area of 95 to 150 Sqmm after carrying of repairs/jointing work, testing etc complete all as specified and directed. Note : Necessary joints, LT/UG cable, will be measured & paid seperately under relevant item in BOQ..
M&L for LT cable jointing kit, straight through shrinkable type with jointing materials,lugs etc suitable for LT UG armoured aluminium conductor cable of size 10 to 25 Sqmm all as specified & directed.
M&L for LT cable jointing kit, straight through shrinkable type with jointing materials,lugs etc suitable for LT UG armoured aluminium conductor cable of size 50 to 70 Sqmm all as specified & directed.
M&L for LT cable jointing kit, straight through shrinkable type with jointing materials,lugs etc suitable for LT UG armoured aluminium conductor cable of size 95 to 150 Sqmm all as specified & directed.
S & F 80mm dia GI pipe, light grade, including its accessories as in cable protection laid under road crossing , plinth , floor , path , culverts and wall including taking up old unserviceable pipe complete all as specified.
S & F 50mm dia GI pipe, light grade, including its accessories as in cable protection laid under road crossing , plinth , floor , path , culverts and wall including taking up old unserviceable pipe complete all as specified.
S & F 40mm dia GI pipe, light grade, including its accessories as in cable protection laid under road crossing , plinth , floor , path , culverts and wall including taking up old unserviceable pipe complete all as specified.
M&L in replacement MCCB TPN, 415 V, of 63 Amps,10 KA capacity with adjustable thermal release, magnetic release with spreader terminals in existing LT panel board and ensure compatability with existing MCCBs, in fit and finish complete all as specified
M&L in replacement MCCB TPN, 415 V, of 100 Amps,10 KA capacity with adjustable thermal release, magnetic release with spreader terminals in existing LT panel board and ensure compatability with existing MCCBs, in fit and finish complete all as specified
M&L in replacement MCCB TPN, 415 V, of 160 Amps,16 KA capacity with adjustable thermal release, magnetic release with spreader terminals in existing LT panel board and ensure compatability with existing MCCBs, in fit and finish complete all as specified
M&L in replacement MCCB TPN, 415 V, of 200 Amps,16 KA capacity with adjustable thermal release, magnetic release with spreader terminals in existing LT panel board and ensure compatability with existing MCCBs, in fit and finish complete all as specified
M&L in replacement MCCB TPN, 415 V, of 250 Amps,35 KA capacity with adjustable thermal release, magnetic release with spreader terminals in existing LT panel board and ensure compatability with existing MCCBs, in fit and finish complete all as specified
M&L in replacement MCCB TPN, 415 V, of 400 Amps,35 KA capacity with adjustable thermal release, magnetic release with spreader terminals in existing LT panel board and ensure compatability with existing MCCBs, in fit and finish complete all as specified
M&L in replacement MCCB TPN, 415 V, of 630 Amps,50 KA capacity with adjustable thermal release, magnetic release with spreader terminals in existing LT panel board and ensure compatability with existing MCCBs, in fit and finish complete all as specified
M&L for painting to old /existing steel surface of LT panel board indoor/outdoor type by scrapping out rusted, uneven surface and applying two coat of synthetic enamel paint over one coat of primer all as specified and directed.
M&L for painting to old /existing steel surface of angle iron frame/bracket of LT panel board /Feeder pillar by applying two coat of black bituminuous paint all as specified and directed.
M&L cement concrete 1:3:6 type CI (using 20 mm graded) aggregate against damaged portion of panel mounting/ Structure, filling and mass concrete complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60×60 cm × 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI strip 32 × 6 mm by means of bolts, nuts, check nuts and washers of GI and GI tubing 20 mm bore light grade for PCC (1:3:6) type C1 pre cast RCC (1:2:4) type b1 cover slab 545×54×5 cm with one handle for lifting made out of 8mm dia MS bar, wire mesh, 20 mm bore GI tubing for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No.3 of SSR part-1
Jack Electrolinks Private Limited
Jyothis Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .